P1 19.0 0 6 12 18 24h - DOC DIFFdocdif.fr.grpleg.com/general/MEDIAGRP/NP-FT-GT/292285GB...Mosaic...

4
Mosaic Thermostat programmable 767 21 N 292285/05 °C 19.0 S S F T T M W P1 12 0 6 18 24h Auto ® Softkey Set point Day of week Absence mode (see page 4) Lighted Ring prompt to confirm adjusted menu options/parameters Rotating knob • Selection of the menu options or adjusting the parameters. • Temperature setting Confirmation of the selection or the actual settings of the parameters Softkey Program Activates the selected program Presence mode (see page 4) N L 230V~ Use the same power supply phase for supply and relay. For an optimal temperature control it is advisable to use a contactor when operating with a load greater than 4A. 1 Displays the MENU Back Information Adjust number of days (1-30) of absence and presence-mode Softkeys AUTO Technical data Supply voltage: 230V 50/60Hz Power consumption: 1 W Relay output: 1 changeover contact 8A 250V~ cos ϕ = 1 Accuracy: ± 1 s /day, day under typical installation conditions single strand multi strand Wire cross-sections: 1,5…4 mm 2 1,5…2,5 mm 2 Programs (saved by EEPROM) 4x predefined, 1x individual Running reserve: 100h for all settings Range of adjustment: +7°C ... +30°C Frost protection temperature: +7°C Storage temperature: - 10°C to +60°C Ambient temperature - 5°C to +50°C Operating principle: Typ 1.B. EN 60730-1 Energy class IV = 2%, EU 811/2013

Transcript of P1 19.0 0 6 12 18 24h - DOC DIFFdocdif.fr.grpleg.com/general/MEDIAGRP/NP-FT-GT/292285GB...Mosaic...

Page 1: P1 19.0 0 6 12 18 24h - DOC DIFFdocdif.fr.grpleg.com/general/MEDIAGRP/NP-FT-GT/292285GB...Mosaic Thermostat programmable 767 21 N 292285/05 19.0 C M T W T F S S P1 0 6 12 18 24h Auto

Mosaic™

Thermostat programmable767 21

N 2

9228

5/05

°C 19.0S S F T T M W

P1

12 0 6 18 24h

Auto

®

Softkey

Set point

Day of week

Absence mode (see page 4)

Lighted Ringprompt to confirm adjusted menu options/parameters

Rotating knob• Selection of the menu options or adjusting

the parameters.• Temperature setting

Confirmation of the selection or the actual settings of the parameters

Softkey

Program

Activates the selected program

Presence mode (see page 4)

N L

230V~

Use the same power supply phase for supply and relay.For an optimal temperature control it is advisable to use a contactor when operating with a load greater than 4A.

1

Displays the MENU

Back

Information

Adjust number of days (1-30) of absence and presence-mode

Softkeys

AUTO

Technical dataSupply voltage: 230V 50/60Hz

Power consumption: 1 W

Relay output: 1 changeover contact 8A 250V~ cos ϕ = 1

Accuracy: ± 1 s /day, day under typical installation conditions

single strand multi strand

Wire cross-sections: 1,5…4 mm2 1,5…2,5 mm2

Programs (saved by EEPROM) 4x predefined, 1x individual

Running reserve: 100h for all settings

Range of adjustment: +7°C ... +30°C

Frost protection temperature: +7°C

Storage temperature: - 10°C to +60°C

Ambient temperature - 5°C to +50°C

Operating principle: Typ 1.B. EN 60730-1

Energy class IV = 2%, EU 811/2013

Page 2: P1 19.0 0 6 12 18 24h - DOC DIFFdocdif.fr.grpleg.com/general/MEDIAGRP/NP-FT-GT/292285GB...Mosaic Thermostat programmable 767 21 N 292285/05 19.0 C M T W T F S S P1 0 6 12 18 24h Auto

MENU

SETUP (PARAMETRAGE)

LANGUAGE (LANGUE) ENGLISH / DEUTSCH / FRANCAIS / ESPANOL / NEDERLANDS

DATE/TIME DATE TIME SUMMERTIME EUROPE, US NONE, USER DEFINED

TEMP. -SETTINGS T° COMFORT T° REDUCED

WALL COMPENS. + 0.0°C

PRESENCE TIME 6-22 O’CLOCK 0-24 O’CLOCK

DISPLAY CONTRAST BRIGHTNESS

PROGRAMMS

P1- OFFICE

0 6 12 18 24h

08:00 - 19:00

SSFTTM WSELECT INFO MODIFY RESET

P2- RETAIL 1

0 6 12 18 24h

09:00 - 19:00

SSF T T M W SELECT INFO MODIFY RESET

P2- RETAIL 2

0 6 12 18 24h

09:00 - 19:00

SSFTTM W SELECT INFO MODIFY RESET

P4- DAILY

0 6 12 18 24h

08:00 - 20:00

SSFTTM WSELECT INFO MODIFY RESET

P5- USER DEF. USER DEFINED CREATE / SELECT INFO, MODIFY, DELETE

OPTIONS INFO THERM PROGdd/mm/yyyy VERSION xx

RESET SETTINGS

1

Reset

3d

3d

3d

°C

°C

°C

19 0

190

160

Presence mode - with indication of the residence days

Absence mode - with indication of the absence days

Heating engaged

actual temperature

reduced temperature

comfort temperature

Absence-frost - with indication of the absence days

Symbols

Manual regulation

°C 19.0

S S F T T M W

P1

12 0 6 18 24h

Program information

0 6 12 18 24h

S S F T T M W

P 1

°C °C °C

19 0 190 160

AUTO

1

Modifies the setpoint directly in steps of 0,5 °C; this action doesn’t affect the chosen mode. With the next automatic switching, either due to a program or because of a return to the auto mode, the set-point is set back to the pre-selected value.

2

manual operating mode

Page 3: P1 19.0 0 6 12 18 24h - DOC DIFFdocdif.fr.grpleg.com/general/MEDIAGRP/NP-FT-GT/292285GB...Mosaic Thermostat programmable 767 21 N 292285/05 19.0 C M T W T F S S P1 0 6 12 18 24h Auto

SETUP TIME

10:30 00

SETUP TIME

10:30 00

Time, date and summertime (Daylight saving time)

DATE/TIME

TIME

DATE

SUMMERTIME

FEBRUARY 2007 M T W T F S S 1 2 3 4 5 6 7 8 9 10 1112 13 14 15 16 17 1819 20 21 22 23 24 2526 27 28

FEBRUARY 2007 M T W T F S S 1 2 3 4 5 6 7 8 9 10 1112 13 14 15 16 17 1819 20 21 22 23 24 2526 27 28

MENU

SETUPPROGRAMS

OPTIONS

SETUP

LANGUAGE

DATE/TIME TEMP. -SETTINGS

DATE/TIME

TIMEDATE

SUMMERTIME

TIME

10:00 00

DATE/TIME

TIME

DATE

SUMMERTIME

DATE/TIME

TIME

DATE

SUMMERTIME

SUMMERTIME

EUROPE US

NONE

SUMMERTIME

NONE

US

USER DEFINED

OK

OK

OK

1

AUTO

Select language

LANGUE

ENGLISH DEUTSCH

FRANCAIS

MENU

PARAMETRAGEPROGRAMMES

OPTIONS OK

1

AUTO

OK

PARAMETRAGE

LANGUEHORADATAGE

T° DE PROGR.

OK

OK

OK

OK

OK

OK

OK

OK

OK

MARCH 2008 M T W T F S S 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1617 18 19 20 21 22 2324 25 26 27 28 29 3031

MARCH 2008 M T W T F S S 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1617 18 19 20 21 22 2324 25 26 27 28 29 3031

OK

OK

OCTOBER 2007 M T W T F S S 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31

OCTOBER 2007 M T W T F S S 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31

OK

Temperature setting

MENU

SETUPPROGRAMS

OPTIONS

1

AUTO

TEMP. -SETTINGS

T° COMFORT

T° REDUCED OK

OK

SETUP

DATE/TIME

LANGUAGE

TEMP. -SETTINGS

OKT° REDUCED

16.0°C

OK

Contrast/brightness adjustment

MENU

SETUPPROGRAMS

OPTIONS OK

1

AUTO

SETUP

TEMP. -SETTINGS

DATE/TIME

DISPLAY

OK

OK

DISPLAY

CONTRAST

BRIGHTNESS

OK

DISPLAY

BRIGHTNESS

DISPLAY

CONTRASTBRIGHTNESS

OKDISPLAY

CONTRAST

OK

DISPLAY

CONTRASTBRIGHTNESS

Wall compensation

MENU

SETUPPROGRAMS

OPTIONS OK

1

AUTO

SETUP

TEMP.-SETTINGS

DATE/TIME

WALL COMPENS.

OK

WALL COMPENS.

26.6°CREFERENCETEMPERATURE

OFFSET 0.0°C OK

The wall compensation enables the difference to be adjusted if the temperature values differ from the room temperature.

Comfort time when present

MENU

SETUPPROGRAMS

OPTIONS OK

1

AUTO

SETUP

WALL COMPENS.

TEMP. -SETTINGS

PRESENCE TIME

OK

PRESENCE TIME

6-22 O‘CLOCK0-24 O‘CLOCK

OK

Comfort range setting

TEMP. -SETTINGS

T° COMFORT T° REDUCED OK

T° COMFORT

19.0°C

OK

3

TEMP. -SETTINGS

T° COMFORT T° REDUCED

Page 4: P1 19.0 0 6 12 18 24h - DOC DIFFdocdif.fr.grpleg.com/general/MEDIAGRP/NP-FT-GT/292285GB...Mosaic Thermostat programmable 767 21 N 292285/05 19.0 C M T W T F S S P1 0 6 12 18 24h Auto

Absence mode

Presence mode

0 6 12 18 24h

19.0°C

1

PRESENCE MODE

0 6 12 18 24h

1 day

PRESENCE MODE

0 6 12 18 24h

S S F T T M W

19.0°C

2d

Adjust number of days (1-30) of presence-mode

After expiration of the adjusted days or pressing the key AUTO returns to AUTO mode.

After expiration of the adjusted days or pressing the key AUTO returns to AUTO mode.

If button 1 is not pressed for 20s or button OK is pressed after the display of presence mode screen, an unlimited number of days will be set.

0 6 12 18 24h

16.0°C

ABSENCE MODE

1 0 6 12 18 24h

6 days

ABSENCE MODE

0 6 12 18 24h

S S F D D M M

16.0°C

6d

AUTO

AUTO

Adjust number of days (1-30) of absence-mode

If button 1 is not pressed for 20s or button OK is pressed after the display of presence mode screen, an unlimited number of days will be set.

0 6 12 18 24h

ANTI-FREEZE

ABSENCE MODE

1 0 6 12 18 24h

6 days

ABSENCE MODE

0 6 12 18 24h

S S F T T M W

7.0 °C

6d

Activates the comfort level between 6:00-22:00/0:00-24:00, the rest of the day the reduced level is active. This mode can be initiated for an unlimited time or for a number of days between 1 and 30.

During the absence mode the reduced or the frost protection level is activated throughout the day. The user can choose which level is actually used. This mode can be initiated for an unlimited time or for a number of days between 1 and 30.

OK

OK1

AUTO

1

AUTO

OK

Create program 5

1

AUTO

OK

0 6 12 18 24h

SSFTTM W

CREATE block 1

P500:00

MENU

PROGRAMSSETUP

OPTIONS

OK

Modify programs

P2-RETAIL 1

INFO

SELECT

MODIFY

MODIFY block 1 / 1

P2

SSFTTM W

0 6 12 18 24h

09:30 - 19:00

MENU

PROGRAMSSETUP

OPTIONS PROGRAMS

P3-RETAIL 2

P1-OFFICE

P2-RETAIL 1

P2-RETAIL 1

INFOSELECT

MODIFY

1

AUTOOK

OK

OK

OK

MODIFY block 1 / 1

P2

SSFTTM W

0 6 12 18 24h

09:30 - 19:00

OK

Changes ON/OFF-times

PROGRAMS

P5-USER DEFINED

P3-RETAIL 2

P4-DAILY

OK

OK

P5 - USER DEFINED

CREATE

CREATE block 1

P5

SSFTTM W

OK

CREATE block 1

P5

SSFTTM W

SELECT ADD. DAYSENTER TIME

CREATE block 1

P5

SSFTT WM

OK

CREATE block 1

P5

SSFTTM W

SELECT ADD. DAYSENTER TIME

OK

0 6 12 18 24h

SSFTTM W

CREATE block 1

P507:00

OK

0 6 12 18 24h

SSFTTM W

CREATE block 1

P507:00 - 07:15

0 6 12 18 24h

SSFTTM W

CREATE block 1

P507:00 - 10:00

OK

EXIT PROGRAMMINGAND STORE VALUES NOW?

OK

CREATE block 1

SSFTTM W

OK

OK

0 6 12 18 24h

SSFTTM W

CREATE block 1

P510:15

CREATE block 2

P5

SSFTTM W

CREATE block 1

P5

SSFTTM W

NEW DAYSBLOCKENTER TIMEQUIT & SAVE

P5-USER DEFINED

INFOSELECT

MODIFY

4