P 035 01 12 Prospekt TX150 EN:P 035 00 09 Prospekt · PDF fileThis means the Froling TX ... H1...

12
www.froeling.com New output size 199 kW available!

Transcript of P 035 01 12 Prospekt TX150 EN:P 035 00 09 Prospekt · PDF fileThis means the Froling TX ... H1...

www.froeling.com

New output size

199 kW available!

Heating with Wood Chips and Pellets

Wood pellets are made of natural wood. The large quantities ofwood shavings and sawdust from the wood processingindustries are compacted and pelleted without being treatedbeforehand. Pellets have a high energy density and are easy todeliver and store. These are just two of the advantages that

make pellets the perfect fuel for fully automatic heating systems. Pellets are delivered by tanker, whichunloads the pellets directly into the storage room.

The fuels: wood chips or pellets

Wood chips are a fuel that is domesitcally produced, unaffectedby economic crisis, and environmentally friendly. Wood chipproduction also guarantees jobs for local residents. This proveswhy wood chips are the perfect fuel, not just economically, butalso from an ecological perspective as well. The leftover

branches and treetops as well as the sawmill waste is shredded into wood chips. Quality classes aredetermined by the wood used.

From the very beginning, Froling has specialized in the efficient use of wood as an energy source. Today,Froling sets the standard in modern biomass technology. Froling's firewood, wood chip, and pellet boilersare successfully in operation all over Europe. All of our products are manufactured at our factories in Austriaand Germany. Froling's service network ensures that we can handle all inquires quickly and effectively.

www.froeling.com

TX__

The new Froling TX

User friendly, sturdy, economical and reliable: the new TX from Froling is guaranteed to impress in every aspect.

This boiler can efficiently burn both wood chips and pellets due to its well designed fully automatic system.

Froling also offers a wide range of fuel feeder systems for virtually all requirements.Optimum energy consumption is ensured by the detailed system engineering. This means the Froling TXcan offer reliable, high-quality heating!

High requirements - Smart solutions

1

2

3

4

6

5

A1

www.froeling.com

TX__

Outstanding features:

1

2

3

4

5

6

A1

Ventilated step grate for pre-drying of materials and optimum combustion.

Tilted combustion grate to ensure full burn and grate cleaning during operation.

Easily accessible heat-resistant ash removal screw.

Premium-quality high-temperature combustion chamber with firebrick lining for minimum emissions and optimal combustion at a high efficiency.

A standing tubular heat exchanger with efficiency optimisation system (WOS) with automatically driventurbulators to clean the flue gas path in the boiler.

Fully insulated to minimize radiant heat loss.

Minimal space requirement due to the optimal unit layout.

Clear structure - Perfect detail

Stoker screw

Step grate

Tilted grate

High-temperature firebrick-lined combustion chamber

Ash removal screw

Mobile ash container

1

2

3

4

6

5

1

2

3

4

6

5

High-temperature combustion chamber with firebrick lining

www.froeling.com

TX__

Combustion grate 45° Combustion grate 90°

Example of a complete TX 150 system with spring blade agitator FBR

Smart grate technique

The combination of aventilation pre-drying stepgrate and a tilted grateensures optimum combustionfor both dry and dampmaterial. The system doesnot have to be shut down forcleaning and no furtherignition is required.

Systematically User-Friendly

Feature: Lambdatronic H 3200 controller

Your benefits:• The lambda control supplied as a standard part, gives precise combustion control. • Large, easy-to-read control unit with graphic display.• Menu-based operation with online help• Boiler operation from the living room made possible through the use of the RBG 3200

The Froling bus system makes it possible to install extension modules at any location. The local controls can be installed wherever needed: on the boiler, the heatdistributor, the tank, the living room, or an additionalbuilding. A further benefit is that electricwiring is kept to a minimum.

The new RBG 3200 room console makesthe system even more user-friendly. Theheating system is conveniently controlledfrom your living room. It is extremely easy toread off all key values, status messages, andwith a touch of a button to change settings.

Froling takes you into the future with the new H 3200 boiler control unit. The control unit is optimized to your requirements and the illuminatedgraphic display panel guarantees that each operating status is clearlyindicated. The menu makes operation simple. The main heating and hotwater functions can be selected by simply selecting the function keys.

The equipment comes pre-wired, saving on time-consuming electricalinstallation.

www.froeling.com

TX__

Spring blade agitator (FBR)During the filling process thereinforced spring arms arepositioned under the stirrerplate. Through further andfurther rotations, thematerial is moved into theopen trough channel. Thisfeed system is maintenance-free.

Articulated arm feeding unitThe articulated arm feedingunit ensures flawless fullyautomatic operation. Energyand maintenance costs arekept to a minimum.The unique shape of thetrough and the feedscrew, with progressiverotation circles of thescrew blade ensures areliable fuel feed.

The system is free-flowingand therefore energy effi-cient, even when operatingat full load.

Additional Froling feeder systems available upon request.

Fuel feeder systems

Some examples from a wide range of set-up options:

External store

External storage with an option ofdirect loading into the fuel storagearea. This storage area can beextended at a low cost.

Introduction withbunker filling screw

Store connected to bunker fillingscrew. Existing or similar windowopenings can be used as loadingopenings.

Storage Above

Storage above the boiler room. Fuelis fed to the boiler using a downpipe.Here we recommend a rotary valve!

www.froeling.com

TX__

Froling systems engineering enablesefficient energy management. Heatmanagment can include as many as4 tanks, 8 hot water tanks, and18 heating circuits. You can also benefitfrom the option of connecting other typesof energy production sources, such assolar energy panel systems.

Feature: Systems engineering for optimumenergy consumption.

Your benefits:• Complete solutions for every need.• The components work perfectly together.• Incorporation of solar energy

TX

mu

lti-bu

ildin

g s

yste

m w

ith la

ye

red

tan

k a

nd

Un

ice

ll NT

-S

Technical specifications

Heizkessel- und Behälterbau GesmbHA-4710 Grieskirchen, Industriestr. 12Austria: Tel +43 (0) 7248 606 • Fax +43 (0) 7248 606-600Germany: Tel +49 (0) 89 927 926-0 • Fax +49 (0) 89 927 926-219E-mail: [email protected] • Internet: www.froeling.com

Further technical details upon request.We will be pleased to assist and advise you.

PO350112 - All illustrations have a symbolic character.We reserve the right to make technical changes without prior notification where necessary.Misprints and omissions reserved. Source for third party images: www.aboutpixel.de

DIMENSIONS - TX 150 200 250

H Height of boiler [mm] 1880 1880 1880

H1 Height of flow connection / return connection [mm] 1935 1935 1935

H2 Height of flue gas pipe connection without FGR [mm] 770 960 960

H3 Height of flue gas pipe connection with FGR [mm] 1410 1445 1445

B Width of boiler [mm] 1970 2070 2070

L Total length of system [mm] 2620 2980 2980

L1 Length of boiler [mm] 1090 1400 1400

L2 Length of stoker unit [mm] 940 970 970

L3 Length of ash container [mm] 590 610 610

TECHNICAL SPECIFICATIONS - TX 150 200 250

Nominal heat output (woodchips W30 as per ÖNORM) [kW] 150 199 250

Required fuel consumption at nominal load (G50/W30) [kg/h] 48 61 76

Flue gas pipe diameter [mm] 200 250 250

Electrical connection [V / Hz / A] 400 V / 50 Hz / 35 A

Weight of the boiler (inc. stoker unit, exc. water) [kg] 2730 3380 3400

Weight of the combustion chamber [kg] 855 1120 1120

Weight of the heat exchanger [kg] 1000 1280 1280

Water capacity [l] 440 570 570

Maximum permitted boiler operating temperature [°C] 90 90 90

Minimum return temperature [°C] 65 65 65

Maximum permitted operating pressure [bar] 3 3 3

Flue gas temperature at rated load [°C] 150 150 150

Boiler efficiency [%] 92,1 92,9 93,7