Overhaul Report Form by, J. a. Bessie @2008
description
Transcript of Overhaul Report Form by, J. a. Bessie @2008
OVERHAUL RECORD
DIESEL ENGINE OVERHAUL REPORTMV / MT. Place :
Date :
Voyage No. :
Main Eng./ Aux Eng. No. : 1 FORMCHECKBOX
2 FORMCHECKBOX 3 FORMCHECKBOX Maker / Type : Engine No. : Running Hours (H) :1). Since new : .H 2). Since last Overhauled Piston / Cylinder No : 1 : / .............. H 2 : / ............... H 3 : . / . H
4 : / ............... H 5 : ............... / .H 6 : ... / H 7 : / H 8 : . / . HReported by,
( ) Chief EngineerMV / MT.
Piston crown Top clearancePlace / Date:
Inspected by:
Standard clearance:
Max. permissible clearance:
Signature:
Unit : mm
Cyl No.
Pos1
2
3
4
5
6
7
8
FA
MV / MT.
main bearing clearancePlace / Date:
Inspected by:
Standard clearance:
Max. permissible clearance :
Signature:
Unit : mm
Cyl No.
Pos1
2
3
4
5
6
7
8
Front endAft endThrust
Center
MV / MT.
Side clearance of crank web & thrust padPlace / Date:
Inspected by:
Standard clearance:
Max. permissible clearance :
Signature:
Unit : mm
Cyl No.
Pos1
2
3
4
5
6
7
8
F
A
C
MV / MT.
turbo charger clearancePlace / Date:
Inspected by:
Standard clearance:
Max. permissible clearance :
Signature:
Unit : mm
RMLNKDesignR2R1Measurement
R2R1
MV / MT.
crank pin clearancePlace / Date:
:Inspected by:
Standard clearance:
Max. permissible clearance :
Signature:
Unit : 1/100mmCyl No.
Pos
1
2
3
4
5
6
7
8
F
A
Cyl No.
Pos1
2
3
4
5
6
7
8
F1
A1
MV / MT.
cross head clearancePlace / Date:
Inspected by:
Standard clearance:
Max. permissible clearance :
Signature:
Unit : 1/100mm
Cyl No.
Pos1
2
3
4
5
6
7
8
F1
A1
F2
A2
MV / MT. cylinder liner inside diameterPlace / Date:
Inspected by:
Standard Diameter:
Max. permissible Diameter:
Signature:
Cyl. No.
P. No.
Pos
D1
D2
D3
D4D5D6D7D81
X
Y
2
X
Y
3
X
Y
4
X
Y
5
X
Y
6
X
Y
7
X
Y
MV / MT
piston ring gapPlace / Date:
Inspected by:
Standard ring Gap:
Max. permissible ring Gap :
Signature:
Pst. No.
Pos.
Pos
D1
D2
D3
B1
B2
B3
B4
1
X
Y
2
X
Y
3
X
Y
4
X
Y
5
X
Y
6
X
Y
7
X
Y
MV / MT.
piston ring clearancePlace / Date:
Inspected by:
Standard clearance:
Max. permissible clearance :
Signature:
Pst. No.
Pos
1
2
3
4
5
6
7
8
C1 P-S/F-A C2 P-S/F-AC3 P-S/F-AC4 P-S/F-A
1Perawatan dan perbaikan Mesin , Contoh form laporan Overhaul Mesin File J. A. Bessie, Materi pelajaran ATT di BP3IP, Jakarta @2012