Pavilion XL profile
Height
260 102”Width
534 210” Length
534 210”
Pavilion XL
simple double
Pavilion XL
PAVILION XL
MAXIMUM HEIGHT TO WHICH IT CAN BE INSTALLED
Maximium permissible wind pressures by the Landscape pavilion
Height
260 102”Length
1060 416” Width
534 210”
column profileHeight
10 3,9”Width
10 3,9”Height
10 3,9”Width
4,7 1,7”
1. Sea
2. Rural flat
3. Rural rough
4. Urban
5. Mayor cities
Calculations based on Basic document SE-AE. Structural secutiry. [Framework Document SS-BA. Structural Safety in Building] which establishes the loads to be considered, and Eurocodigo 9 (Spanish Association for Standardisation and Certification. Eurocode 9), a monographic standard for aluminium structures. “This information is for guidance only. The safety of the pavilion will depend on the anchoring system used and the type of floor on which it is installed.” For more exact information, please contact your distributor.
2
3
4
5
30 m
41 m
67 m
109 m
187 m
18 m
28 m
48 m
84 m
146 m
9 m
14 m
26 m
49 m
90 m
Wind speed A: 93,60 Km/h B: 97,20 Km/h C: 104,40 Km/h
949500 949600
MAXIMUM HEIGHT TO WHICH IT CAN BE INSTALLED
Maximium permissible wind pressures by the Landscape pavilion
Height
260 102”Width
355 140” Length
355 140”
Pavilion L
simple double
Pavilion L
column
Pavilion L profile
profile
PAVILION L
Height
260 102”Length
710 279,5”Width
355 140”Height
7 2,7”Width
7 2,7”Height
10 3,9”Width
2,2 0,8”
1. Sea
2. Rural flat
3. Rural rough
4. Urban
5. Mayor cities
Calculations based on Basic document SE-AE. Structural secutiry. [Framework Document SS-BA. Structural Safety in Building] which establishes the loads to be considered, and Eurocodigo 9 (Spanish Association for Standardisation and Certification. Eurocode 9), a monographic standard for aluminium structures. “This information is for guidance only. The safety of the pavilion will depend on the anchoring system used and the type of floor on which it is installed.” For more exact information, please contact your distributor.
2
3
4
5
30 m
41 m
67 m
109 m
187 m
18 m
28 m
48 m
84 m
146 m
9 m
14 m
26 m
49 m
90 m
Wind speed A: 93,60 Km/h B: 97,20 Km/h C: 104,40 Km/h
949400 949300
Pavilions
P
Rol
ling
blin
d
Z Floor
G Deploye
K Aluminium / Canadian cedar
R
Louv
ers s
ide
pane
l Q
A
lum
iniu
m /
Can
adia
n ce
dar s
ide
pane
l
V
Fabr
ic s
ide
pane
l
A Structure
CEILINGS
M Waterproof sunroof
N Sheer curtain set
T Alu
min
ium
side
pan
el d
eplo
ye
I Fabric
J Sliding roof
U
Alu
min
ium
side
pan
el g
rid
plan
ter
S
Shel
f sid
e pa
nel
H Grid
W
Slid
ing
door
X
Gla
ss s
ide
pane
l
B Bioclimatic
L Venetian waterproof
Y Polycarbonate
SID
E P
AN
ELS
Z Floor
G Aluminium ceiling grid
P Polycarbonate
B
Ced
ar w
ood
louv
ers s
ide
pane
lA
lum
inum
louv
ers s
ide
pane
l
Q
Can
adia
n ce
dar s
uper
ior s
ide
pane
lA
lum
iniu
m su
peri
or si
de p
anel
W
Gla
ss si
de p
anel
A Structure
L Canadian cedar woodAluminium ceiling
N Sheer curtain set
S
Shel
f sid
e pa
nel
J Venetian waterproof
T Alu
min
ium
side
pan
el d
eplo
ye
U
Alu
min
ium
side
pan
el g
rid
plan
ter
V
Fabr
ic si
de p
anel
R Can
adia
n ce
dar w
ood
side
pan
elA
lum
ium
side
pan
el
B Bioclimatic
X
Slid
ing
door
SID
E P
AN
ELS
CEILINGS
268 269