For efficient swimming pool heating
n Fully automatic
n Quiet in operation
n Requires very little regular maintenance
n No fumes
n Kind to the environment
n Economical to run
F E A T U R E S
R
OUTDOORHEAT PUMPS
OUTDOOR HEAT PUMPS
Outdoor Heat PumpsThe diagram above illustrates the way in which a heat
pump transfers and upgrades heat form the outside air to
the pool water. The heat pump technology offers an
extremely efficient method of pool water heating which
does not rely upon the sunshine, just air!
Calorex heat pumps are manufactured to suit a large variety
of applications. The ‘Ambient’ range will heat the pool
water throughout a typical UK summer season, operating
when the outside temperature is above 7 degrees centigrade.
Models 631-1531 incorporate an internal by-pass facility.
The ‘10X’ range, with a more comprehensive design, offers
an extended season usage. This model continues to operate
even when the outside air temperature is as low as zero
degrees centigrade. The ‘10X’ range also incorporates an
internal by-pass system which allows for a range of pool
water flow rates.
The ‘Y’ range is similar to the ‘10X’ model, but will still
operate when the outside temperature drops to -15 degrees
centigrade thus offering 12 months usage. This range
provides efficient All-year heating for both indoor and
outdoor pools.
QualityCalorex units are built to last and have been supplied to the
swimming pool industry for decades. Thousands of Calorex
units have been successfully operating in some thirty
countries. The choice of materials for the components is
aimed at a long reliable life. The cabinets are steel, first
galvanised and then plastic coated to provide resilient
protection against external elements. Pool water heat
exchangers are of high quality to ensure maximum
resistance to pool chemical corrosion. Models 631-1531
include a titanim heat exchanger with a five year warranty.
Each unit is thoroughly tested and inspected and must meet
a precise performance standard before leaving the factory!
The Calorex factory and products are approved to several
internationally accepted standards of quality and safety. All
Calorex equipment is fully guaranteed and dispatched
complete with comprehensive instructions.
Free Heat From The Air
5:1 4.5:1 4:1 3.5:1
Total heat to pool divided by energy consumed = Co-efficient of Performance (COP)
Free HeatFromThe Air
Free units of heat
Paid units of heat
total units ofheat to pool(COP)
HEATING SEQUENCE
OUTSIDE AIR
FAN EVAPORATOR (Heat Collector)
EXPANSION VALVE
COMPRESSOR
CONDENSER(Heat transferred to pool water)
HEATED POOL WATER
WATER FROM POOL
FILTER PUMP
POOL
SCHEMATIC ILLUSTRATION
Wid
th
Dep
th
Hei
ght
Electrical Data
65 1902.9-6.820 50-15021.8 5.2
AW510ALX Model 510X Single PH 20
68 56950
69
56
AW320AM 4.6
10.3
10.3
13.8
13.8
17.5
17.5
24
37
0.9
2.0
2.0
2.7
2.7
3.5
3.5
4.5
9.1
13.4
7
12
7
16
8
21
10
11
25
33
10 16
20
10
25
13
30
15
18
35
4.6
1.1
1.1
1.0
1.0
2.0
2.0
2.0
4.5
3.9
55
49
49
50
50
52
52
55
69
79
126
126
134
134
144
144
158
393
Model 320 Single PH
Model 631 Single PH
Model 631 Three PH
Model 831 Single PH
Model 831 Three PH
Model 1231 Single PH
Model 1231 Three PH
Model 1531 Three PH
Model 3020 Three PH
Model 7020 Three PH
AW631AM
AW631BM
AW831AM
AW831BM
AW1231AM
AW1231BM
AW1531B
AW3020B
AW7020B
8.0
8.0
11.2
11.2
12.8
12.8
16.8
16.8
2.0
2.0
2.5
2.5
2.8
2.8
4.0
3.8
13
5
11
6
15
7
21
9
13
10
20
10
25
10
30
15
50-150
50-150
50-150
50-150
50-150
50-150
50-150
50-150
130
92-138
92-138
92-138
92-138
128-192
128-192
128-192
66
2.0-3.0
2.0-3.0
2.2-4.5
2.2-4.5
3.0-7.8
3.0-7.8
2.9-6.8
2.9-6.8
55
55
55
55
55
55
60
60
9817151227
567
567
792
792
792
792
1227
1227
615
615
715
715
715
715
715
715
647
647
895
895
895
895
981
981
69
118
118
120
120
182
182
Model 510X Three PH
Model 710X Single PH
Model 710X Three PH
Model 910X Single PH
Model 910X Three PH
Model 1210X Single PH
Model 1210X Three PH
Model 1510X Three PH
AW510BLX
AW710ALX
AW710BLX
AW910ALX
AW910BLX
AW1210ALXS
AW1210BLX
AW1510BLX
PRO
DU
CTCO
DE
Hea
tto
Pool
(kW
)
Pow
erCo
nsum
ed(k
W)
Supp
lyCa
paci
ty(A
mp)
Supp
lyFu
se(A
mp)
Dimensions (mm)
1212
817
1075
1075
1075
1075
1075
1075
1180
1700
1950
605
485
485
485
485
485
485
485
1090
1340
640
1255
1255
1255
1255
1355
1355
1355
1212
Pool
Wat
erFl
owRa
te(l/
m)
Pres
sure
Dro
p(m
head
)*
Noi
seLe
vel@
3m(d
BA
)
Unp
acke
dW
eigh
t(kg
)
Hea
tPum
pTy
pe
UK
Seas
on
AM
BIE
NT
AIR
DEF
ROST
SUM
MER
POO
LH
EATI
NG
BY-
PASS
DEF
ROST
EXTE
ND
EDSU
MM
ERPO
OL
HEA
TIN
G
68 5843.950 13056 13.4
AW710ALY Model 710Y Single PH 20 12111.2
11.2
12.8
12.8
16.8
16.8
21.8
37
2.5
2.5
2.8
2.8
4.0
4.0
5.2
9.1
11
6
15
7
21
9
13
25
33
10
25
10
35
15
20
35
50-150
50-150
50-150
50-150
50-150
50-150
122750-150
66
2.2-4.5
2.2-4.5
3.0-7.8
3.0-7.8
2.9-6.8
2.9-6.8
2.9-6.8
4.5
55
55
55
55
60
60
65
69
121213401950
792
792
792
792
1227
1227
1700
715
715
715
715
715
715
715
1090
895
895
895
895
981
981
981
1212
121
125
125
187
187
194
399
Model 710Y Three PH
Model 910Y Single PH
Model 910Y Three PH
Model 1210Y Single PH
Model 1210Y Three PH
Model 1510Y Three PH
Model 3020Y Three PH
Model 7020Y Three PH
AW710BLY
AW910ALY
AW910BLY
AW1210ALYS
AW1210BLY
AW1510BLY
AW3020BY
AW7020BY
REVE
RSE
CYCL
ED
EFRO
ST
ALL
YEA
RRO
UN
DPO
OL
HEA
TIN
G
PRODUCT DESCRIPTION
Calorex Air To Water Heat Pumps
A low cost swimming pool heater that
uses the latest heat pump technology to
extract free heat from the outside air.
SPECIFICATIONS
Notes: The minimum operating temperatures for the above are: 7OC Ambient air for ambient air defrost models0OC Ambient air for by-pass defrost type (10X) models-15OC Ambient air for reverse cycle defrost (Y) models
Heat to pool capacities shown relate to a 20OCair temperature
All models and are refrigerant charged with R407C.
* Minimum and maximum pressure drops indicated for ‘10X’ and ‘Y’ range units.
If you should require further technical information please do not hesitate to contact us.
NATIONALACCREDITATION
OF CERTIFICATIONBODIES
CERTIFICATE REGISTRATION NUMBER 7660
ISO 9002REGISTERED COMPANY
01.06.07
10 20 30 40 50 60 70 80 90 100
24
25
26
27
28
29
30
31
32
33
74
76
78
80
82
84
86
88
90
92
100 200 300 400 500 600 700 800 900 1000 1100
Model320
Model631
Model831
Model1231
Model1531
(3 phase only)
Pool Surface Area ft2
Pool Surface Area m2
Wat
erte
mpe
ratu
reO
C
Wat
erte
mpe
ratu
reO
F
eg 42m2 pool @ 28oC requires a model 831
Graph A
May
-Sep
tem
berS
easo
n(a
ppro
x22
-24
wee
ks)
Sum
mer
Seas
on
Apr
il-O
ctob
erSe
ason
(app
rox
30-3
2w
eeks
)Su
mm
erPl
usSe
ason
Mar
ch-N
ovem
berS
easo
n(a
ppro
x38
-40
wee
ks)
Exte
nded
Sum
mer
Seas
on
10 20 30 40 50 60 70 80 90 100
24
25
26
27
28
29
30
31
32
33
74
76
78
80
82
84
86
88
90
92
100 200 300 400 500 600 700 800 900 1000 1100
Model 510X
Model 710X
Model 910X
Model 1210X
Model 1510X
Pool Surface Area ft2
Pool Surface Area m2
Wat
erte
mpe
ratu
reO
C
Wat
erte
mpe
ratu
reO
F
(3 phase only)
eg 450ft2 pool @ 84oF requires a model 1210X
Graph B
10 20 30 40 50 60 70 80 90 100
24
25
26
27
28
29
30
31
32
33
74
76
78
80
82
84
86
88
90
92
100 200 300 400 500 600 700 800 900 1000 1100
Model 510X
Model 710X
Model 910X
Model 1210X
Model 1510X
Pool Surface Area ft2
Pool Surface Area m2
Wat
erte
mpe
ratu
reO
C
Wat
erte
mpe
ratu
reO
F
(3 phase only)
eg 40m2 pool @ 82oF requires a model 1210X
Graph C
Note: The sizing graphs shown
on this page assume the
following UK conditions:
• Te entire pool is constructed
in-ground.
• Ground water level
is below pool construction.
• Floating heat retention
cover is used 20 hrs
per day.
• Average depth of water
@1.3 metres.
For sizing of equipment outside of
these design parameters please
consult the H & V design team.
Conversion Factor
To convert to sq. ft to sq.m
multiply by 0.0929.
To convert from sq.m to sq.ft
divide by 0.0929.