OSHA Region IV
Electrical Outreach
General Industry Photos
29 CFR 1910 Regulations
General Industry Photos
• Standard– 1910.254(d)(9)(iii)
• Description– Welding lead cable splice were not insulated.
All splices and metal parts of cables and parts must be guarded.
General Industry Photos
• Standard– 1910.303(b)(1)
• Description– Building wiring systems were not properly
installed. Wiring draped over building surfaces.
General Industry Photos
• Standard– 1910.303(b)(2)
• Description– Equipment not installed IAW listing
requirements.
General Industry Photos
• Standard– 1910.303(g)(1)(iii)
• Description– Access to circuit breaker panels blocked.
General Industry Photos
• Standard– 1910.303(g)(2)(i)
• Description– Live parts exposed.
General Industry Photos
• Standard– 1910.303(g)(2)(i)
• Description– The receptacle was not properly installed in
the junction box which exposed energized parts.
General Industry Photos
• Standard– 1910.303(g)(2)(i)
• Description– Broken electrical receptacle exposing
energized parts.
General Industry Photos
• Standard– 1910.303(g)(2)(i)
• Description– Live parts of 480 VAC electrical system
exposed. All live parts are required to be guarded.
General Industry Photos
• Standard– 1910.303(g)(2)(i)
• Description– Front cover removed from circuit breaker
panel. Live parts exposed.
General Industry Photos
• Standard– 1910.304(f)(5)(v)
• Description– Portable light with metal guard which is
required to be grounded.
General Industry Photos
• Standard– 1910.304(f)(5)(v)
• Description– The ground pin was removed from the
electric plug.
General Industry Photos
• Standard– 1910.305(a)(2)(iii)(G)
• Description– Electrical wiring was not protected from
damage. Lying across road where cranes and other vehicular traffic could pass over the wiring.
General Industry Photos
• Standard– 1910.305(b)(2)
• Description– The faceplate was removed from the
receptacle exposing the energized parts.
General Industry Photos
• Standard– 1910.305(e)(1)
• Description– Electrical systems were not designed for wet
and damp locations
General Industry Photos
• Standard– 1910.305(g)(2)(iii)
• Description– The electrical plug did not have adequate
strain relief which causes stress on the contacts.
General Industry Photos
• Standard– 1910.305(j)(1)(iv)
• Description– Electric cords and cables lying in water.
General Industry Photos
• Standard– 1910.305(j)(1)(iv)
• Description– The receptacle which was approved for wet
and damp locations was damaged.
General Industry Photos
• Standard– 1910.307(b)(1)
• Description– Electrical wiring was not approved for
hazardous locations. Paint spray area.
General Industry Photos
• Description– Electrical wiring and systems were not
installed IAW NEC.