ORISSA HIGH COURT: CUTTACK TENDER NOTICE 1461 I · ORISSA HIGH COURT: CUTTACK TENDER NOTICE ......
Transcript of ORISSA HIGH COURT: CUTTACK TENDER NOTICE 1461 I · ORISSA HIGH COURT: CUTTACK TENDER NOTICE ......
ORISSA HIGH COURT: CUTTACKTENDER NOTICE
No. 1461 I Dtd. Oq.02.2.0!g
Price quotations in sealed cover are invited from OEMs I Authorized Dealers for
purchase of Fire-fighting Equipments to be installed and used in Orissa High Court.
The tenders in sealed cover should be addressed to "The Registrar (Judicial),
Orissa High Court, Cuttack" and superscribed with "TENDER FOR SUPPLY OF
FIRE FIGHTING EQUIPMENTS". The bidders must submit the following documents
alongwith the price quotations in the sealed tenders:-
a) Demand Draft of Rs.10,0001- (Rupees Ten Thousand) only towards EMD
(refundable) from any Nationalized Bank in favour of "The Registrar (Judicial),
Orissa High Court, Cuttack" payable at Cuttack.
b) Demand Draft of Rs.l,OOOI- (Rupees One Thousand) only towards Tender Cost
(non-refundable) from any Nationalized Bank in favour of 'The Registrar (Judicial),
Orissa High Court, Cuttack" payable at Cuttack.
c) Copy of GST Registration Certificate.
d) Copy of latest valid Tax Clearance Certificate.
e) Copy of PAN Card.
f) Copy of IT Clearance Certificate for the Assessment Year 2016-17.
The nature, quantity and specifications of the items shall be as per Annexure-I and
Annexure-II respectively. (Please visit Court's website www.orissahighcourt.nic.in or
Court's Notice Board for details). The sealed tenders are to reach the undersigned on or
before 05.03.2018 by 03:00 P.M., which will be opened on the same day at 04:00P.M. in
the Chambers of the Registrar (Judicial) in presence of the bidders I their representatives.
The authority reserves the right to accept or reject any part of or all tenders
without assigning any reason thereof.
~AssistantRe~strar (Admn.)
Orissa High CourtMemo No.14~:2(2.) dtd. OQ.02.201iCopy forwarded to:1. Office Notice Board2. The Technical Director, NIC for uploading in ORC website
~J{/C\'~
Assistant Registrar (Admn.)Orissa High Court
- 1-
ANNEXURE-I
SI. Name of the equipments/apparatus NumberNo. requiredl. Fire Resistance Suit 32 Pairs2. Fire Proximity Suit 8 Sets3. Breathing Apparatus Set with Spare Cylinder 8 Sets4. Gum Boot 32 Pairs5. Rope (polyamide) 30 meters6. Rope (caramental) 30 meters7. Fire Extinauishers
a) Water stored pressure type 20 nos.b) C02 (4.5Kg capacity) 30 nos.c) C02 (9 Kg capacity) 2 nos.d) DCP stored pressure type (9 Kg capacity) 20 nos.e) ABC type extinguisher stored pressure type (1 Kg capacity) 25 nos.n Foam type extinguisher (9 ltr. capacity) 10 nos.
8. Emergency Life Saving Apparatus 25 nos.9. Smoke Extractor 8 nos.10. Fire Fighting System using other inert gases (ckan agen~ --
such as FM 200, NOVEC Nitrogen, etc.
N.H.: (1) The device under S1. No.-I0 shall be used in the RenovatedJudges' Library of Orissa High Court.
(2) The bidders must inspect the site(s) before submitting theirbids.
-2-
"ANNEXURE-II
SPECIFICA TION.1. GUM BOOT: -
Gum boot with steel toe; approved from the D,G.M.S. for adult (size 8, 9, 10),
made out of high quality rubber. The Gumboots should be provided with stock unit lining
for durability and comfort. The soiL' should be designed to avoid skidding and provided
firm grips. The Gum boots should be electric shock proof and it should be confirming to
relevant BfS.
2. RESCUE LINE (1" DIA, 30 MTRS LENGTW .
.Rescue line of (30 I11ts) IOIlI.'.1" or 24111111diameter/ 3""circulllferellee of 3 standard
Polyamide Multi-Filament Rope conforming to IS-4572-1992. It should be flexible which
can be used suitably during rescue operation. The bidders must have to furnish
manufacturer certificate.
3. RESCUE UNE (Yz" DIA, 30 MTRS LENGTH).
The Yl" or 13 111mdin caramcntal rope having breaking strength :22 kN should be
flexible, which can he used for rescue purpose. The length or rope should he 30 Mtr.
4. 11..'\ Sf.:T WITH SPARE CYLINDER, (ADVANCE MODEL): -
Automatic positive preSSUI"L'self-contained compressed air-breathing Apparatus.
Comprising antistatic back pink with simple adjustable harness demand regulator. by-
pass valve. pressure gauge. warning whistles, lightweight. superior lJlIcdit:, Iuccmask.
Speech transmitter. Compressed air cylinder having 300 bar pressure 06.8 liter water
capacity and 50 MTS working duration with the following features-
i) Air Cylinder.
This shall be COITOSlon ("lIld impact resistant made of light weight carbon
composite the size of the cylinder shall be such that it can contain sufficient air up to
2040 Ltrs for working duration of 50 minutes when it is charged 300 bar pressure. The
cylinder should be duly approved by the "Chief Controller of Explosive (C.C.E).
Nagpur". The valve switch is screwed into COI1lPI\'sscd air cylinder and approved
according 10 EN- 144 CF marked.
ii) Demand Valve.The long operated demand valve should be securely connected to the Face Mask. It
shall be capable of delivering lip to 5()U LPM of air ~lI1Jshall activate with the first breathof the user.
-3-
iii) Back Plate Assemblv and Bodv Harness.
It shall be of Light weight. The material used shall be tire and chemical resistant and
back plate should be orthopedically designed. It should he of adjustable type so that the
length of carrying plate can be adjusted according to user's height. It shall he ideal for the
confined space entry rescue operations. It should have latest technology preferably a
facility for mounting of air cylinder through cam lock. The body harness should pass
through the back plate should be wearer's friendly and shall have 100% Kevlar webbing
for highest level flame resistant. It should be safe in every respect for carrying load and
all buckles used in the harness of quick release type.
iv) Pressure Reducer.
It should be provided in 3 brass housing. which is attached to the lower part of the
carrying plate. On the pressure reducer. there should he the blo» out release valve. The
10\\ pressure warning signal/ device (audible) should he mounted on the pressure reducer
and not Oil the pressure gauge line as to increase safety factor of the set.
v) Face Mask.
This shall be made flame resistant material the reflex seal on the outer mask shall
be so designed to provide excellent sealing to the face counter. It shall have demand
valve on its outside to avoid the obstruction to the wearer as well as to have clear vision.
An inner luce mask shall be provided to reduce dead space. clear transmission of voice. It
shall also have a wide vision visor made of polycurbonate material. The head strap
provided with quick release and lightening dependable mechanism.
vi) Pressure Gauge.
The Pressure gauge should preferably Digital as well as Analogue type. The
integrated control 1Init. and eicctroni c personal A lert Sa fely Systern lor compressed ai r
breathing apparatus should capable to assure the safetv of the users hv continuously
monitoring the following factors.
a) Pressure
b) Temperature
c) Remaining service Time
d) Battery capacity
-4-
The integrated control unit should give alarm if the user is motionless for a period
of :20 seconds so that the fire fighter can be easily traced out in case of his
unconsciousness during the rescue operation and immediate help can be provided.
vii) Weight
The weight of the set should not exceed 12 kg. The light weight set will enable the
user to move quickly.
The entire set should be as per FN-137 type -[I. The face mask should he as per EN-
136. the back plate, face piece and demand valve should be individually CE marked.
Above all the approval certificates of E.N and C.c.E. Nagpur should be provided with
each set. Preference may be given to advance features incorporated in the B.A Sets
which will be suitable for all fire fighters.
viii) D.S.U:- A Distress Signal unit should be provided with each set and the duration
time should be :20-40 Seconds.
ix) Metal Box:- A suitable metal box should be provided for safe storage of the
complete B.A set. The internal surface of the box should be provided with I" foam
cushion to avoid damage.
Further. advance suitable additional facilities in the B./\ Set & its accessories shall be
given priority.
The B.A Set should contain the following Advance Features.
i). Wireless Heads Up Display (HUD): - The set should have Wireless Heads Up
Display (!IUD) system which fits securely inside the facernask and display cylinder
pressure in quarter increments along with turn back signal. Being wireless it provides
hands free at a glance cylinder pressure information to the fire fighter.
ii). Automatic Start Up Test: - The set should have an Automatic Start Up Test
system to check the cylinder pressure when the cylinder is pressurized and electronic
functions for safe use of the equipment to ensures every time for the tire lighter.
iii), Ambient Air Latch: - Ambient Air Latch system to enable the use of ambient air
while in standby or approaching the lire which saves precious air from the cylinder.
Other additional facilities also be taken in to consideration,
-., -
S~fe ~kuM/e¥5. ~"_ .... ------ --- - -c". (PORTABLE).
A. Water Turbine Mechanism.
The portable exhauster should be specially designed on water turbine
mechanism for extractor of vapor. smoke, and fumes from a confined space. It should be
of light weight maximum 24 kgs. free from electrical hazardous and should of simple
operation. Inlet water pressure should be 7 bars. normal water flow 245 LPM, air
extraction capacity minimum 50m3/min. The body should be of stainless steel 304 grade.
peloton wheel should be of gun metal. all piping should be of corrosion resistant. 631l11l1
male and female instantaneous coupl ing of stainless steel should be provided for inlet and
outlet facility. The fan should he nylon type. The ducting should be PYC coated name
resistant nylon fabric reinforced with spring steel wire having a minimum length 5 mtrs.
The device should be so designed to facilitate conservation of water.
B. Portable SmoJ{e Exhllustel·/ Ventilator Petrol Engine driven.
Portable Smoke Exhauster/ ventilator should be imported make a reputed
product and light weight with weight less than 45 Kgs. cOl.llpact having t-an size-16" with
minimum 10 blades capable of airflow output of minimum 40.000 cu. M/hr with
minimum ::; h.p. 4-stroke petrol engine. It should upcrntc fur minimum 75 minutes at full
speed with full fuel tank.
Ventilator set should be supplied complete with collapsible duct (S Ill). 10 deg hit
accessory and water mist adaptor. It should also be equipped with ah electronic meter
displaying the hours of operation and the engine rotation speed. The equipment shall he
CE marked.
6. FIRE RESISTANCE SUIT: - (1)
Three Layered Fire fighter Suit made with inherently flame retardant material with
following design &. material combination and each garment must be supplied with
manufacturer's CE Certificate and as per EN 469:2007-02.
DESIGN OF THE GARMENT:
Jacket
a) Fire tighter Jacket should be provided with FR lipper and FR Velcro (Hook S:
Loop)
-6-
b) The Zipper should be Concealed by a flap of the outer shell with Velcro provision
for extra protection.
c) Under the armpits special features should be provided for easy movement of Arms.
d) At the wrist FR Knitted material should be provided for firm fit and to ensure that
heat is not transmitted through the wrists.
e) 2" FR Retlective trim to be used at bottom round, middle round and arms round to
ensure high visibility.
f) Two pockets with flaps at the bottom half on both sides and a pocket on the inside
of the jacket with zipper for closure and safe keeping of important documents.
g) The entire Jacket should be stitched with FR Threads.
h) The Jacket should be CE Certified meeting the requirements of EN469: 2007-02
Pant
a) Fire Fighter Pant should be provided by two zippers on the sides for easy wear and
removal with comfort since speed is essential to the tire tighter while wearing or
removing.
b) The FRVelcro should ensure that the zippers are concealed with flaps and held III
place at the waist.
c) FR Elastic should bc provided at the waist for linn lit.
d) Two side pockets should be provided for storing any important accessories.
e) /\11 additional layer of' cuter shell FR and Antistatic fabric at the knee portion for
additional reinforcement to enhance the life of the garment during kneeling or any
such rigorous lire and rescue operation should be provided.
f) A pocket at the side thigh portion should be provided for holding a lire axe or any
other tools.
g) 2"FR Retlective trim to be provided at the ankle portion for high visibility.
h) The Pant is CE Certified meeting the requirements of EN469 : 2007-02.
G Ion'S.
+ The multi layer gloves should have the out shell made of flame and abrasion
resistant Leather with additional layer for moisture & heat protection. The cuff
should be made with knit Flame Resistant material. The gloves should be stitched
-7-
with high strength flame resistant Kevlar thread. An FR lime green/ silver
reflective tape shall be positioned on outer sick of the gloves.
• Gloves should be CE marked and certified to meet the requirements of EN-
659:2008 standard. Copy or certificate to be submitted with offer.
Fire Fighter Gum Boot.(Safctv Boot)
• FfRE FIGHTER BOOTS will be made of flame Retardant Rubber Boots will be
fitted with Steel Toe Cap and Steel Mid Sale (CSA Class-I certified). Boots will be
Electric Shock Resistant (CSA Omega) and will have a heat and oil resistant anti-
slip sole.
• The boots will have heavy canvas lining with sponge cushion inside. The boots will
provide ankle protection. The boots will be water proof. Boots wil] have strong
carrying loops arrangement on top for ease of donning.
• The boots will be CE marked and Certified to EN-IS090 standards. Copy of
certi ficate to be submitted with offer.
Fire Fighter Helmate.
• The helmet will be designed for Structural Fire Fighters exposed to extreme fire
fighting conditions.
• It will be Light-weight and made of High Strength Para-Aramid Kevlar reinforced
fiberglass shell.
• II wil] also have a PU IIIIp"CI Liner for protection
• [I will have a ratchet dial-size adjuster (52-64 ern) suitable for all head sizes. It will
be supplied with a 2-point chin strap with buckle closure. It will have a neck
protector made of FR leather.
• It wil] have a Wide brim lor ~{)od cranial protection in case fireman falls sideways
8: have a External Retractable Face Shield Visor with possibilit, of 180 degree
rotation.
• It will have a provision for fitrnent of Torch on the helmet side and the torch should
be special certified torch for LIse by firemen in hazardous areas. It will have a
Xenon bulb with simple pushbutton ON / OFF. It will run on 4 A/". barteries.
• The helmet will be certified to EN-443:200H standard & visor to EN-14458
standard. Copy of certi ficate to be submitted with offer.
- 9-
'•. ·l
7. FIRE PROXIMITY sun:Proximity suit should be designed for fighting fire at a proximate distance and for
a closer approach. It allows minor flame licks. Proximity suit should be multilayered with
the outer layer is of imported aluminized fiber glass/ rayon fabric/ NOMEX 01"
equivalents. The suit should have a vapor barrier and thermal barrier or specified
material. II should confirm to the Defence and International specifications.
Aluminized Protective Clothing made from Multi layer fabric ensemble consists of:
Outer laver : Aluminized fabric on aramide backing
Middle Layer : PU membrane moisture barrier
Thermal Liner: FR felt quilted to FR face cloth
Th is enti re set consists of:
Jacket with central zipper and flap Size M. L. XL (with provision for B/\ set pouch]
Trouser with suspenders Size iVI. L. XL
Hood consisting of heat resistance visor on the front and this overlaps the fronl
part tll" the Jacket and is held ill place by loops. The aluminized fabric is reinforced on an
FRP helmet. Gloves up to mid wrists Boots with nitri le rubber heat resistant sole
with zipper (height up to ankle) Sample Swatch for all 4 layers to he enclosed with
tender offer.
-tt-
---------~~-------