ORFEOv6r3
10. GeV muons
This data MC comparison was made with the last version of ORFEO.Here a new version of the smearing tool is implemented, this is based on the position smearing in the 3 directions: X,Y,Z of the 2 end points of the microtrack. In such a way the basetrack smearing of the slopes is obtained for free. In addiction, with this technique, the smearing ellipse in the Tx:Ty plane has main axes in the longitudinal and transversal direction, as seen in the data.
![Page 2: ORFEOv6r3 10. GeV muons This data MC comparison was made with the last version of ORFEO. Here a new version of the smearing tool is implemented, this is.](https://reader036.fdocuments.net/reader036/viewer/2022062511/551549bd55034685568b520e/html5/thumbnails/2.jpg)
Efficienze dal brick vuoto
esposto ai cosmiciEfficienza ufficiali
Eff lead MC pions Eff no lead MC pions
![Page 3: ORFEOv6r3 10. GeV muons This data MC comparison was made with the last version of ORFEO. Here a new version of the smearing tool is implemented, this is.](https://reader036.fdocuments.net/reader036/viewer/2022062511/551549bd55034685568b520e/html5/thumbnails/3.jpg)
Electrons 6 GeV
• The events were generated with OpRoot
• The smearing parameters are: Sx=0.4 micron, Sy=0.25 micron, Sz=2.5 micron. (these value were obtained with a tooning on the data)
![Page 4: ORFEOv6r3 10. GeV muons This data MC comparison was made with the last version of ORFEO. Here a new version of the smearing tool is implemented, this is.](https://reader036.fdocuments.net/reader036/viewer/2022062511/551549bd55034685568b520e/html5/thumbnails/4.jpg)
TRIGGER dataMC
![Page 5: ORFEOv6r3 10. GeV muons This data MC comparison was made with the last version of ORFEO. Here a new version of the smearing tool is implemented, this is.](https://reader036.fdocuments.net/reader036/viewer/2022062511/551549bd55034685568b520e/html5/thumbnails/5.jpg)
Slopes resolution(Tmicro-Tbase)
MC data
![Page 6: ORFEOv6r3 10. GeV muons This data MC comparison was made with the last version of ORFEO. Here a new version of the smearing tool is implemented, this is.](https://reader036.fdocuments.net/reader036/viewer/2022062511/551549bd55034685568b520e/html5/thumbnails/6.jpg)
eCHI2P vs PHThis is the results of the micro slopes resolution
simulation (eCHI2P) and of the micro pulse height parametrization (bt PH)
DatiMC
bg rejected
![Page 7: ORFEOv6r3 10. GeV muons This data MC comparison was made with the last version of ORFEO. Here a new version of the smearing tool is implemented, this is.](https://reader036.fdocuments.net/reader036/viewer/2022062511/551549bd55034685568b520e/html5/thumbnails/7.jpg)
Bt angle resolutionBin(i-1)=T(i)-T(1), i>1
MC Dati
![Page 8: ORFEOv6r3 10. GeV muons This data MC comparison was made with the last version of ORFEO. Here a new version of the smearing tool is implemented, this is.](https://reader036.fdocuments.net/reader036/viewer/2022062511/551549bd55034685568b520e/html5/thumbnails/8.jpg)
Base Pulse and eCHI2P DatiMC
![Page 9: ORFEOv6r3 10. GeV muons This data MC comparison was made with the last version of ORFEO. Here a new version of the smearing tool is implemented, this is.](https://reader036.fdocuments.net/reader036/viewer/2022062511/551549bd55034685568b520e/html5/thumbnails/9.jpg)
Number of segments followed without propagation (strongly related to micro track efficiencies)
Dati
MC without Efficiencies micro track
rejection
Eff. As measured inEmpty brick
(only cosmics exposition)
MC+eff.
![Page 10: ORFEOv6r3 10. GeV muons This data MC comparison was made with the last version of ORFEO. Here a new version of the smearing tool is implemented, this is.](https://reader036.fdocuments.net/reader036/viewer/2022062511/551549bd55034685568b520e/html5/thumbnails/10.jpg)
MC: no correlation betweenMicro tracks momentum and pulse height by construction
Data
![Page 11: ORFEOv6r3 10. GeV muons This data MC comparison was made with the last version of ORFEO. Here a new version of the smearing tool is implemented, this is.](https://reader036.fdocuments.net/reader036/viewer/2022062511/551549bd55034685568b520e/html5/thumbnails/11.jpg)
Pions 4 GeV
• The events were generated with OpRoot
• The smearing parameters are: Sx=0.25 micron, Sy=0.25 micron, Sz=2.5 micron. (these value are the same used for all the “official” productions)
![Page 12: ORFEOv6r3 10. GeV muons This data MC comparison was made with the last version of ORFEO. Here a new version of the smearing tool is implemented, this is.](https://reader036.fdocuments.net/reader036/viewer/2022062511/551549bd55034685568b520e/html5/thumbnails/12.jpg)
TRIGGER dataMC
![Page 13: ORFEOv6r3 10. GeV muons This data MC comparison was made with the last version of ORFEO. Here a new version of the smearing tool is implemented, this is.](https://reader036.fdocuments.net/reader036/viewer/2022062511/551549bd55034685568b520e/html5/thumbnails/13.jpg)
Slopes resolution(Tmicro-Tbase)
MC data
![Page 14: ORFEOv6r3 10. GeV muons This data MC comparison was made with the last version of ORFEO. Here a new version of the smearing tool is implemented, this is.](https://reader036.fdocuments.net/reader036/viewer/2022062511/551549bd55034685568b520e/html5/thumbnails/14.jpg)
eCHI2P vs PHThis is the results of the micro slopes resolution
simulation (eCHI2P) and of the micro pulse height parametrization (bt PH)
DatiMC
bg rejected
![Page 15: ORFEOv6r3 10. GeV muons This data MC comparison was made with the last version of ORFEO. Here a new version of the smearing tool is implemented, this is.](https://reader036.fdocuments.net/reader036/viewer/2022062511/551549bd55034685568b520e/html5/thumbnails/15.jpg)
Bt angle resolutionBin(i-1)=T(i)-T(1), i>1
MC Dati
![Page 16: ORFEOv6r3 10. GeV muons This data MC comparison was made with the last version of ORFEO. Here a new version of the smearing tool is implemented, this is.](https://reader036.fdocuments.net/reader036/viewer/2022062511/551549bd55034685568b520e/html5/thumbnails/16.jpg)
Base Pulse and eCHI2P DatiMC
![Page 17: ORFEOv6r3 10. GeV muons This data MC comparison was made with the last version of ORFEO. Here a new version of the smearing tool is implemented, this is.](https://reader036.fdocuments.net/reader036/viewer/2022062511/551549bd55034685568b520e/html5/thumbnails/17.jpg)
Number of segments followed without propagation (strongly related to micro track efficiencies)
Dati
MC+eff.Assuming eff.=84.%
(84.% at theta<0.1mrad measured data)
![Page 18: ORFEOv6r3 10. GeV muons This data MC comparison was made with the last version of ORFEO. Here a new version of the smearing tool is implemented, this is.](https://reader036.fdocuments.net/reader036/viewer/2022062511/551549bd55034685568b520e/html5/thumbnails/18.jpg)
MC: no correlation betweenMicro tracks momentum and pulse height by construction
Data
![Page 19: ORFEOv6r3 10. GeV muons This data MC comparison was made with the last version of ORFEO. Here a new version of the smearing tool is implemented, this is.](https://reader036.fdocuments.net/reader036/viewer/2022062511/551549bd55034685568b520e/html5/thumbnails/19.jpg)
Transversal and longitudinal resolution for simulated 10.GeV pions at 0.7 mrad