Ordering Information - Industrial Controlsestore.industrialcontrolsonline.com...Contact Honeywell...

6
Ordering Information Ordering Information A complete assembly consists of two parts, a transmitter and sensor which must be ordered separately. • Transmitter PN#: Two certified versions are available: - S3KUX (UL and CSA (cUL) certified) - S3KAX (ATEX and IECEx certified) • Sensor PN#: All certified ATEX, IECEx, UL, CSA (cUL) with two digits to specify gas type and range: - e.g. S3KXXC1SS (C1 denotes Carbon Monoxide, with a default range of 0-300ppm and user configurable for ranges from 0-100ppm to 0-999ppm) Transmitter S3KUX S3KAX Series 3000 XPIS UL & CSA (cUL), ATEX and IECEx certified transmitter, supplied complete with wall or pipe mounting bracket, 1 x ¾” NPT cable entry, 1 x ¾” NPT to M20 adaptor, 1 x hex wrench set, weatherproof cover, operating magnet, configuration / test certificate and instruction manual. Units are 100% inspected prior to dispatch from the factory. Order the required sensor separately. Sensor part numbers and available gases S3KXSO1SS Oxygen 0-25%VOL S3KXSC1SS Carbon Monoxide 0-300ppm (default) 0-100 to 0-999ppm selectable S3KXSH1SS Hydrogen Sulfide 0-15ppm (default) 0-10 to 0-50ppm selectable S3KXSH2SS Hydrogen Sulfide 0-100ppm (default) 0-50 to 0-500ppm selectable S3KXSL1SS Chlorine 0-5ppm (default) 0-5 to 0-20ppm selectable S3KXSZ1SS Ozone 0-0.4ppm (default) 0-0.4 only S3KXSS1SS Sulfur Dioxide 0-15ppm (default) 0-5 to 0-20ppm selectable S3KXSX1SS Chlorine Dioxide 0-1ppm (default) 0-1ppm selectable S3KXSM1SS Nitrogen Monoxide 0-100ppm (default) 0-100ppm selectable S3KXSN1SS Nitrogen Dioxide 0-10ppm (default) 0-5 to 0-50ppm selectable S3KXSG1SS Hydrogen 0-1000ppm (default) 0-1000ppm selectable S3KXSG2SS Hydrogen 0-10,000 (default) 0-10,000 selectable S3KXSR1SS Hydrogen Chloride 0-10ppm (default) 0-10 to 0-20ppm selectable S3KXSY1SS Hydrogen Cyanide 0-20ppm (default) 0-20ppm selectable S3KXSF1SS Hydrogen Fluoride 0-12ppm (default) 0-12ppm selectable S3KXSA1SS Ammonia 0-200ppm (default) 0-50 to 0-200ppm selectable S3KXSA2SS Ammonia 0-1000ppm (default) 0-200 to 0-1,000ppm selectable S3KXSP1SS Phosphene 0-1.2ppm (default) 0-1.2ppm selectable Shipping details Shipping carton dimensions: L12.4” x W9.0” x D4.5” (315mm) x (230mm) x (115mm) Approximate weight: 3.3lbs (1.5Kg) Optional accessories S3KCAL Calibration gas flow housing SPPPCC Collecting cone for use with lighter than air gases (H 2 and CO only**) S3KDMK Duct mounting kit (H 2 , CO & H 2 S only**) S3KRMK Remote sensor mounting kit includes: enclosure with sensor socket, 50ft of digital cable and glands, transmitter cable plug, mounting screws Calibration Gases Contact Honeywell Analytics representative Note: ** Contact a Honeywell Analytics representative for the suitability of accessories for other gases.

Transcript of Ordering Information - Industrial Controlsestore.industrialcontrolsonline.com...Contact Honeywell...

Page 1: Ordering Information - Industrial Controlsestore.industrialcontrolsonline.com...Contact Honeywell Analytics: Americas Honeywell Analytics Inc. 405 Barclay Blvd. Lincolnshire, IL 60069

Ordering Information

Ordering Information

A complete assembly consists of two parts, a transmitter and sensor which must be ordered separately.• Transmitter PN#: Two certified versions are available:

- S3KUX (UL and CSA (cUL) certified)- S3KAX (ATEX and IECEx certified)

• Sensor PN#: All certified ATEX, IECEx, UL, CSA (cUL) with two digits to specify gas type and range: - e.g. S3KXXC1SS (C1 denotes Carbon Monoxide, with a default range of 0-300ppm and user configurable for ranges from 0-100ppm to 0-999ppm)

Transmitter

S3KUX S3KAX

Series 3000 XPIS UL & CSA (cUL), ATEX and IECEx certified transmitter, supplied complete with wall or pipe mounting bracket, 1 x ¾” NPT cable entry, 1 x ¾” NPT to M20 adaptor, 1 x hex wrench set, weatherproof cover, operating magnet, configuration / test certificate and instruction manual. Units are 100% inspected prior to dispatch from the factory. Order the required sensor separately.

Sensor part numbers and available gases

S3KXSO1SS Oxygen 0-25%VOL

S3KXSC1SS Carbon Monoxide 0-300ppm (default) 0-100 to 0-999ppm selectable

S3KXSH1SS Hydrogen Sulfide 0-15ppm (default) 0-10 to 0-50ppm selectable

S3KXSH2SS Hydrogen Sulfide 0-100ppm (default) 0-50 to 0-500ppm selectable

S3KXSL1SS Chlorine 0-5ppm (default) 0-5 to 0-20ppm selectable

S3KXSZ1SS Ozone 0-0.4ppm (default) 0-0.4 only

S3KXSS1SS Sulfur Dioxide 0-15ppm (default) 0-5 to 0-20ppm selectable

S3KXSX1SS Chlorine Dioxide 0-1ppm (default) 0-1ppm selectable

S3KXSM1SS Nitrogen Monoxide 0-100ppm (default) 0-100ppm selectable

S3KXSN1SS Nitrogen Dioxide 0-10ppm (default) 0-5 to 0-50ppm selectable

S3KXSG1SS Hydrogen 0-1000ppm (default) 0-1000ppm selectable

S3KXSG2SS Hydrogen 0-10,000 (default) 0-10,000 selectable

S3KXSR1SS Hydrogen Chloride 0-10ppm (default) 0-10 to 0-20ppm selectable

S3KXSY1SS Hydrogen Cyanide 0-20ppm (default) 0-20ppm selectable

S3KXSF1SS Hydrogen Fluoride 0-12ppm (default) 0-12ppm selectable

S3KXSA1SS Ammonia 0-200ppm (default) 0-50 to 0-200ppm selectable

S3KXSA2SS Ammonia 0-1000ppm (default) 0-200 to 0-1,000ppm selectable

S3KXSP1SS Phosphene 0-1.2ppm (default) 0-1.2ppm selectable

Shipping details

Shipping carton dimensions: L12.4” x W9.0” x D4.5” (315mm) x (230mm) x (115mm) Approximate weight: 3.3lbs (1.5Kg)

Optional accessories

S3KCAL Calibration gas flow housing

SPPPCC Collecting cone for use with lighter than air gases (H2 and CO only**)

S3KDMK Duct mounting kit (H2, CO & H2S only**)

S3KRMK Remote sensor mounting kit includes: enclosure with sensor socket, 50ft of digital cable and glands, transmitter cable plug, mounting screws

Calibration Gases Contact Honeywell Analytics representative

Note: ** Contact a Honeywell Analytics representative for the suitability of accessories for other gases.

Page 2: Ordering Information - Industrial Controlsestore.industrialcontrolsonline.com...Contact Honeywell Analytics: Americas Honeywell Analytics Inc. 405 Barclay Blvd. Lincolnshire, IL 60069

Find out more

Contact Honeywell Analytics:

www.honeywellanalytics.com

www.honeywell.com

AmericasHoneywell Analytics Inc. 405 Barclay Blvd.Lincolnshire, IL 60069USATel: +1 847 955 8200 Toll free: +1 800 538 0363 Fax: +1 847 955 [email protected]

Europe, Middle East, AfricaLife Safety Distribution AGWilstrasse 11-U31CH-8610 UsterSwitzerlandTel: +41 (0)44 943 4300Fax: +41 (0)44 943 [email protected]

Asia Pacific Honeywell Analytics Asia Pacific #508, Kolon Science Valley (I) 187-10 Guro-Dong, Guro-Gu Seoul, 152-050 Korea Tel: +82 (0)2 2025 0307 Fax: +82 (0)2 2025 [email protected]

Please Note:While every effort has been made to ensure accuracy in this publication, no responsibility can be accepted for errors or omissions. Data may change, as well as legislation, and you are strongly advised to obtain copies of the most recently issued regulations, standards, and guidelines. This publication is not intended to form the basis of a contract.

Technical [email protected]

H_Series 3000_DS_V3 2/08© 2008 Honeywell Analytics HW

A60

33

Honeywell Analytics Lines of Business

Commercial Vulcain-brand gas detection from stand-alone units to fully engineered, multi-point systems, all offering cost-effective regulatory compliance » Applications: parking structures, chillers, mechanical rooms, office towers, commercial buildings, shopping centers, swimming pools, golf courses, schools and universities, laboratories

Industrial Renowned Sieger and Manning gas detection systems with advanced electrochemical, infrared and open path sensing technologies » Applications: oil and gas, cold storage, water/wastewater treatment, chemicals, engine rooms, plastics and fibers, agriculture, printing and light industrial

High Tech/Government A complete portfolio of gas and chemical detection instrumentation including infrared spectroscopy (MST) with no cross interference, to Chemcassette paper-based solutions (MDA Scientific) offering detection down to parts per billion » Applications: semiconductor manufacturing and nanotechnology, aerospace propulsion and safety, specialty chemicals industry, research

laboratories, emergency response

Portables Single or multi-gas Lumidor and other premium detectors with compact, lightweight designs ranging from simple alarm only units to advanced, fully configurable and serviceable instruments » Applications: underground utility and electricity ducts, boiler rooms, post-fire sites, sewers, industrial plants, industrial hygiene, first responder teams, remote fleets

Technical Services 24/7 global network includes post-sales service and Systems Integration teams » Emergency call out, service contracts, on/off-site repair, training and commissioning » Complete range of spares, consumables and accessories

Page 3: Ordering Information - Industrial Controlsestore.industrialcontrolsonline.com...Contact Honeywell Analytics: Americas Honeywell Analytics Inc. 405 Barclay Blvd. Lincolnshire, IL 60069

Series 3000 XPIS

2-wire loop powered toxic and oxygen gas detector for use in potentially explosive atmospheres

Page 4: Ordering Information - Industrial Controlsestore.industrialcontrolsonline.com...Contact Honeywell Analytics: Americas Honeywell Analytics Inc. 405 Barclay Blvd. Lincolnshire, IL 60069

The Series 3000 XPIS provides comprehensive monitoring of toxic and oxygen gas hazards in potentially explosive atmospheres, both in and out of doors. This low powered gas detector operates on an industry standard 2-wire 4-20mA loop, making it ideal for both new and retrofit applications. Users can configure the detector without the need of a ‘hot work permit’ by using the LCD and magnetic switches. Fault diagnostic software and configurable calibration intervals simplify maintenance procedures.

The Intrinsically Safe smart sensors are supplied pre-configured and can be ‘hot swapped’ without having to remove power to the detector, saving time and money during commissioning and routine servicing. A remote sensor mounting kit is available that allows the sensor to be mounted up to 50’ (15m) from the transmitter, making it ideal for operation in areas that are difficult to access.

Series 3000 XPIS is supplied with all necessary accessories for easy installation. The detector can be mounted on a wall or support pole using the universal bracket provided. Electrical installation can be made using either conduit or cable with suitable mechanical protection. A ¾” NPT entry and M20 adapter are included as standard. A weatherproof cap is also included for use in the harshest outdoor conditions.

Reliable detection• Proven electrochemical sensing technology • Uses Surecell™ electrochemical cells, ideal for hot and humid environments• Long life sensing elements (typical >2 years)• Patented ‘Reflex’ sensing element verification diagnostics

Reduced installation costs• Universal mounting bracket included, supplied as standard• Explosion proof transmitter allows field wiring to be run along with other non IS instruments• Plug-in sensor removes wiring

Reduced commissioning costs• Sensor recognition software auto configures transmitter• Non-intrusive configuration• Plug and play factory configured sensors

Reduced maintenance costs• IS sensor connection permits hot swap, reducing down time• User programmable calibration frequency • Integral fault diagnostic software• Menu / icon driven calibration procedure

Regulatory compliance• US (UL)• Canadian (CSA)• International (IECEx)• European (ATEX)

Range of optional accessories • Remote sensor mounting kit • Duct mounting kit (for H2, CO and H2S only)• Calibration cup to apply test gas• Collecting cone (for H2 and CO only)

Typical applications• Exploration and drilling platforms• Production platforms • Onshore oil and gas terminals • Refineries and chemical plants• Power plants• Waste water facilities• Utilities

Series 3000 XPIS

Page 5: Ordering Information - Industrial Controlsestore.industrialcontrolsonline.com...Contact Honeywell Analytics: Americas Honeywell Analytics Inc. 405 Barclay Blvd. Lincolnshire, IL 60069

"3.7 / mm0.581

150.0mm / 5.9"

"1.3 / mm0.0850

.0mm

124.0mm

52.0m

m15

15M5 Screw

M4 Screw

Earth Ground

Installation

Dimensions

Mechanical installation options

Pipe mounting Wall mountDuct mount Remote mounting

Series 3000 XPIS is designed for use in potentially explosive atmospheres. As such, installation should follow national guidelines using suitable mechanically protected cable and glands (M20 or ¾” NPT) or conduit (¾” NPT). Use 0.5mm2 (20AWG) to 2.0mm2 (~14AWG) cross sectional area cable as needed to ensure minimum operating voltage at the detector, depending on installed cable length. Various accessories are available for different applications.

Electrical connections

Detector supply Vd

• Assumed to be 17Vdc

Maximum detector signal Im

• Assumed to be 22mA (over range)

Cable resistance Rc • Subject to cable type

Load resistor of control panel RL

• Assumed 33Ω (min) or 250Ω (max)• Subject to controller manufacturer

Controller supply voltage Vc

• Subject to controller manufacturer• Assumed nominal of 24Vdc

Wiring schematics

Terminal Detector Controller Number Terminal Connection

1 + +VE 2 - Signal

Typical maximum installed cable lengths

The maximum cable length between a controller and detector is dependent upon:

• Theminimumguaranteedsupplyvoltagetothedetectorat the controller (VC).• Theminimumoperatingvoltageofthedetector(Vd).• Themaximumcurrentdrawofthedetector(Im).• Theinputimpedanceofthecontroller(RL).• Theresistanceofthecable(RC).

Using the example values opposite, the table below shows typical cable lengths.

For a specific application, the cable manufacturer’s resistance data for a specific cable type must be used.

A cable length calculation formula can be found in the detector’s product technical manual.

1

2

3

1

2

3

+VE

Controller Detector

-VE

Signal Signal

+VERc

Im

Vc

RL

Vd

1

2

1

2

+VE

Controller

Detector

-VE -VE

Signal

+VERc

Im

Vc

RL

Vd

Remote mounting arrangement

Maximum Cable Length km (m)

Cable Size Cable Cable distance km (mi) Cable distance km (mi) Resistance where the Input where the Input Rc Ω/km Impedance Impedance (Ω/mi) RL = 33Ω RL = 250Ω

0.5mm2 (20AWG*) 36.8 (59.2) 3.9 (2.4) 0.9 (0.6)1.0mm2 (17AWG*) 19.5 (31.4) 7.3 (4.5) 1.7 (1.1)1.5mm2 (16AWG*) 12.7 (20.4) 11.2 (7.0) 2.7 (1.7)2.0mm2 (14AWG*) 10.1 (16.3) 14.1 (8.8) 3.4 (2.1)

* Nearest equivalent

Page 6: Ordering Information - Industrial Controlsestore.industrialcontrolsonline.com...Contact Honeywell Analytics: Americas Honeywell Analytics Inc. 405 Barclay Blvd. Lincolnshire, IL 60069

Series 3000 XPIS detector

Use Rugged and reliable gas detector for the protection of personnel from toxic and oxygen gas hazards. Suitable for use in Zone 1 or 2 hazardous areas and North American Class I and II Division 1 or 2 areas.

Detectable gases

Gas Selectable full Default range scale range

Oxygen 25.0%/Vol only 25.0%Vol

Carbon Monoxide 100 to 1,000ppm 300ppm

Hydrogen Sulfide 10 to 50ppm 15ppm

Hydrogen Sulfide 50 to 500ppm 100ppm

Chlorine 5 to 20ppm 5ppm

Ozone 0 to 0.4ppm only 0.4ppm

Sulfur Dioxide 5.0 to 20.0ppm 15ppm

Chlorine Dioxide 0 to 1ppm only 1ppm

Nitrogen Monoxide 0 to 100ppm 100ppm

Nitrogen Dioxide 5 to 50ppm 10ppm

Hydrogen 0 to 1000ppm only 1000ppm

Hydrogen 0 to 10,000 only 10,000ppm

Hydrogen Chloride 10 to 20ppm 10ppm

Hydrogen Cyanide 0 to 20ppm only 20ppm

Hydrogen Fluoride 0 to 12ppm only 12ppm

Ammonia* 50 to 200ppm 200ppm

Ammonia* 200 to 1,000ppm 1,000ppm

Phosphene 0 to 1.2ppm only 1.2ppm

Electrical

Connections and power 2-wire loop powered 17Vdc (+/-10%) to 24Vdc (max) operation 22mA max. over range

Recommended cable 2-wire with shield (90% coverage) or conduit 0.5mm2 (20AWG) to 2.0mm2 (14AWG)

Signal 0-100%FSD 4-20mA Fault = 3mA Calibration due selectable off or 3mA Max. over range 22mA Inhibit (toxic sensors) = Selectable 3mA or 4mA Inhibit (Oxygen sensors) = Selectable 3mA or 17.4mA

Construction

Material Transmitter: Painted aluminium ADC 12, Sensor: 316 stainless steel with PTFE filter

Maximum Dimensions 5.9 x 7.3 x 3.2 inches (excluding mounting bracket) / 150 x 185 x 80mm

Weight 3.3lbs (1450g)

Environmental

IP rating IP65 (EN60529:1992), NEMA 4X

Operating temperature** -40°F to 131°F (-40°C to +55°C)

Operating humidity Continuous 20-90% RH (non-condensing) Intermittent 0-99% RH (non-condensing)

Operating pressure 90-110kPa

Storage conditions 59°F to 86°F (15°C to 30°C) 30-70%RH (non-condensing)

Certification UL/CSA Class l Div 1 & 2, Groups B, C & D UL/CSA Class ll Div 1 & 2, Groups E, F & G

ATEX II 2 G EExd [ia] IIB+H2 T4 (Tamb -20°C to +55°C/ -4°F to 131°F) IECEx Ex d [ia] IIB+H2 T4

* Suitable for applications without NH3 ambient background concentrations only. ** Performance may vary depending on sensor type.

Technical Summary