OptiX RTN 600 Networking and Protection
-
Upload
khalid-alomary -
Category
Documents
-
view
231 -
download
5
description
Transcript of OptiX RTN 600 Networking and Protection
HUAWEI TECHNOLOGIES CO., LTD.
www.huawei.com
Huawei Confidential
Security Level:internal use
OptiX RTN 600 Networking and Protection
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
Study Guide
Before the study on this course, you are supposed to:
Complete the study on the Digital Microwave Communications Principles or have the
relevant knowledge.
Complete the study on the course OptiX RTN 600 Introduction.
Have the general networking knowledge of the SDH optical transmission network.
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
References
OptiX RTN 600 Product Description and OptiX RTN 600 Hardware
Description in the OptiX RTN 600 Package of Documents
Digital Microwave Communications Principles
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
Training Purpose
Upon completion of this course, you will be able to:
Describe the network application of the OptiX RTN 600.
List the common networking modes of the OptiX RTN 600.
List the service types and protection schemes supported by the OptiX RTN 600.
Describe the configuration requirements of the OptiX RTN 600 on each protection
scheme.
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
Table of Contents
1. Network Applications and Networking Modes of the OptiX RTN 600
2. Service Protection and Equipment Protection Schemes of the OptiX
RTN 600
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
Network Application
The OptiX RTN 600 radio transmission system is a short haul digital
microwave transmission system. Each radio frequency (RF) carrier of the
RTN 600 system can transmit 4/8/16xE1 or 1xSTM-1 on the 7 GHz-38 GHz
RF band.
The system provides multiple service interfaces, and it can be flexibly
configured and easily installed. It can form the transmission network with
the optical transmission equipment at the access layer, and can also
provide backhaul links in a mobile telecommunication network or a
private network.
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
Microwave Station TypeClassified by Station Type
Terminal station: It refers to the microwave station that transmits services only in one direction.
Relay station: It refers to the microwave station that transmits services in two directions and is required added to
solve the problem existing in the microwave line of sight communication. The relay station is classified into two
types, active relay station and passive relay station.
Add/Drop relay station: It refers to the microwave station that transmits services in two directions and
adds/drops transmitted services.
Pivotal station: It refers to the microwave station that transmits services in three or more than three directions
and transfers the services in transmission channels in different directions. It is also called the HUB station.
Classified by Transmit and Receive Frequency
Primary station: the transmit frequency is higher than the receive frequency, also named high station.
Non-primary station: the transmit frequency is lower than the receive frequency, also named low station.
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
Microwave Station Type (cont.)
Terminal station
f 1’
Terminal stationPivotal
station
Relay station
Relay station
Terminal station
Primary station
Non-primary station
f 1
f 1’
The Primary station and the Non-primary station are usually arranged alternately in the double-frequency radio link.
Primary station
f 1 > f 1’
f 1
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
Microwave Station Type (cont.)Typical configuration of the OptiX RTN 600 as the Terminal Station
Typical Configuration of the OptiX RTN 600 as the Relay Station
slot20 PXC slot3
PXC slot1PH1 slot4SCC slot2
IF1A slot7IF1A slot5
slot8SL1 slot6
SLE slot3PXC slot1
IF1A slot4SCC slot2
SLE slot3PXC slot1
IF1A slot4SCC slot2
Cable
SL1 slot3PXC slot1
IF1A slot4SCC slot2
slot20 PXC slot3
PXC slot1PH1 slot4SCC slot2
IF1A slot7
IF1A slot5
slot8slot6
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
Microwave Station Type (cont.)
Typical Configuration of the OptiX RTN 600 as the Pivotal station
slot20 PXC slot3
PXC slot1PH1 slot4SCC slot2
IF1A slot7
IF1A slot5
IF1A slot8
SD1 slot6
slot20 PXC slot3
PXC slot1PH1 slot4SCC slot2
IF1A slot7
IF1A slot5
IF1A slot8
IF1A slot6
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
Microwave Network TopologyThe following figures show the basic topologies of the microwave
network.
Ring networkRing
network
Chain networkChain
network
Star networkStar
network
Tree networkTree
network
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
Applications of the OptiX RTN 600
Applications in the Backhaul Network of the Mobile Base Station
Terminal station in the mobile backhaul network
Mobile backhaul chain network
Mobile backhaul tree network
Applications in the Access Network and Private Network
Microwave access network
Complementary network to the SDH ring network
Ring network formed by microwave equipment and SDH equipment
Ring network purely formed by microwave equipment
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
Applications of the OptiX RTN 600 (cont.)
Applications in the Backhaul Network of the Mobile Base Station
Terminal station in the mobile backhaul network
Mobile backhaul chain network
Mobile backhaul tree network
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
Applications of the OptiX RTN 600 (cont.)
Microwave Access Network
VIP client
Service center
Businesscenter
Other client
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
Applications of the OptiX RTN 600 (cont.)
Complementary Network to the SDH Ring Network
Radio link
Radio link Radio link
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
Applications of the OptiX RTN 600 (cont.)Ring Network Formed by Microwave Equipment and SDH Equipment
User network
User network
User network
User network
User network
User network
User network
Transmission network
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
Applications of the OptiX RTN 600 (cont.)
Ring Network Purely Formed by Microwave Equipment
User network
User network
User network
User networkUser network
User network
User network
Transmission network
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
Questions
How many microwave station types can be configured on the OptiX RTN
600? What are them?
Does an OptiX RTN 610 can be set as relay station? Why?
List out four applications of the OptiX RTN 600 in the transmission
network.
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
Table of Contents
1. Network Applications and Networking Modes of the OptiX
RTN 600
2. Service Protection and Equipment Protection Schemes of the
OptiX RTN 600
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
Service Protection and Equipment Protection Schemes of the OptiX RTN 600
The service protection and equipment protection schemes
provided the OptiX RTN 600 are as follows:
1+1 Hot Stand By (HSB) protection
Microwave 1+1 Space Diversity (SD) protection
Microwave 1+1 Frequency Diversity (FD) protection
Sub-network connection protection (SNCP)
Cross-connect and clock unit (PXC) active/standby protection
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
1+1 HSB Protection
Standby
Main
Service access unit
Cross-connect unit
IF unit ODU
ODU(mute)
• In the normal state
Standby
Main
Cross-connect unit
ODU(mute)
ODU
Antenna
• In the switching state
• The microwave HSB protection is also called the hot standby protection.
Service accessunit
IF unit
IF unit
IF unit
Antenna
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
1+1 HSB Protection (cont.)
The 1+1 HSB protection can provide protection for the equipment when the IF board or the ODU failed.
The conditions triggering the 1+1 HSB protection switching include the hardware fault of the IF unit, the hardware fault of the ODU, R_LOS, MW_LOF, R_LOC, R_LOF and MW_RDI. The service interruption time of the 1+1 HSB protection switching is less than 1s.Only the OptiX RTN 620 supports the 1+1 HSB protection.The ODU must use the same sub-band and type of the Primary and Non-primary stations. Only one antenna need be used at one station.Two IF boards need not be configured in the paired slots.
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
1+1 SD Protection
Standby
Main
Service accessunit
Cross-connect unit
ODU
ODU(mute)
• In the normal state IF unit
Standby
Main
ODU
ODU(mute)
• In the switching state
Antenna
Service accessunit
Cross-connect unit
IF unit
IF unit
IF unit
Antenna
Antenna
Antenna
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
1+1 SD Protection (cont.)Because of the multi-path fading, the 1+1 SD installing the main and standby
antennas in different positions to protect the transmission channel.
The conditions triggering the 1+1 SD protection switching include MW_LOF, R_LOS,
R_LOC, R_LOF, MW_FECUNCOR, and B1_SD (when the IF working mode is the
PDH)/B2_SD (when the IF working mode is the SDH).
The 1+1 SD protection switching does not affect the services.
Only the OptiX RTN 620 supports the 1+1 SD protection.
The ODU must use the same sub-band and type of the Primary and Non-primary stations. Two antennas must be used at one station.Two IF boards must be configured in the paired slots.
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
1+1 FD Protection
• In the normal state
• In the switching state
Standby
Main IF unit
IF unit
f1
f2
Cross-connect unit
Service accessunit
Antenna
ODU
ODU
Standby
Main
Service accessunit
Cross-connect unit
ODU
Antenna
IF unit
IF unit
f1
f2
ODU
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
1+1 FD Protection (cont.)The 1+1 FD uses the fading feature diversities between the signals of different frequencies
in the space transmission to protect the active and standby channels in the microwave
transmission.
The conditions triggering the 1+1 FD protection switching include MW_LOF, R_LOS, R_LOC,
R_LOF, MW_FECUNCR, B1_SD (when the IF working mode is the PDH), and B2_SD (when
the IF working mode is SDH).
The 1+1 FD protection switching does not affect the services.
Only the OptiX RTN 620 supports the 1+1 FD protection.
The ODU must use different sub-bands and types at the same station.
Two or one antenna (the hybrid coupler must be used) can be used at one station.
Two IF boards must be configured in the paired slots.
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
Summary of the Microwave Protection Schemes
Cross-connect unit
The service interruption time is less than 1s.
Hardware fault of the IF unit and ODU unit, MW_LOF, R_LOS, R_LOC, R_LOF and MW_RDI
In general, one antenna is used. There is no special requirement on the paired slot. The sub-band of the main and standby ODUs must be the same.
1+1 HSB
IF unitThe services are not interrupted.
The conditions triggering the 1+1 SD protection switching is the service fault.
In this case, the MW_LOF, R_LOS, R_LOC, and R_LOF are not counted as the conditions triggering the HSB switching.
Two antennas must be used. There is the requirement on the paired slot.The sub-band of the main and standby ODUs must be the same.
1+1 SD
IF unitThe services are not interrupted.
The condition triggering the 1+1 FD protection switching is the service fault.
In this case, the MW_LOF, R_LOS, R_LOC, and R_LOF are not counted as the conditions triggering the HSB switching.
One or two antennas can be used. There is the requirement on the paired slot. The sub-band of the main and standby ODUs should be different.
1+1 FD
Switching
Point
Service
Interruption
Switching ConditionConfiguration RequirementProtection
Scheme
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
SNCP
SNCP stands for the sub-network connection protection. The protection is performed when the signal fail
or are degraded. SNCP adopts the 1+1 single-end switching and does not require the support of the
protocol.
The conditions triggering the higher order SNCP include R_LOS、R_LOF、MW_LOF、MW_LIM、MS_AIS、B2_EXC、R_LOC 、AU_AIS、AU_LOP 、HP_LOM . The optional conditions triggering the higher order
SNCP include HP_TIM, HP_UNEQ, B3_EXC and B3_SD.
The required conditions triggering the lower order SNCP include the TU_AIS and TU_LOP. The optional
conditions triggering the lower order SNCP include the LP_TIM, LP_UNEQ, LP_SLM, BIP_EXC, and BIP_SD.
The service interruption time in the SNCP switching is less than 50 ms.
The source board in an SNCP pair must be the line board or the IF board.
If the IF board is configured in one 1+1 protection group, it cannot be configured as the source board of
one SNCP pair.
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
SNCP (cont.)
Active Standby
Selective receiving of services
Bidirectional transmission of services
A
B
C
D
The SNCP is shown in the following figure. Services are transmitted bidirectionally at NE A.
The path that passes through NE B is the active path. The path that passes through NE D is
the standby path.
In the normal state, NE C selectively receives the services from the active path.
In the switching state, NE C selectively receives the services from the standby path.
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
PXC Active/Standby Protection
In the normal state, the active and standby PXC work in the hot standby mode. When the active
unit is abnormal, the standby unit replace the original active one to providing the cross-connect
and clock functions to the entire system.
The conditions triggering the PXC active/standby protection include the loss of the 38M system
clock and the hardware failure.
The conditions triggering the situation that the service unit selects the PXC include loss of the
system clock, loss of the service frame header, loss of the overhead clock, and loss of the
overhead frame header.
The service interruption time in the PXC active/standby switching within 50 ms.
Only the OptiX RTN 620 supports the PXC active/standby protection. When the slots 1 and 3 are
both configured with the cross-connect and clock board PXC, this protection is automatically
enabled.
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
PXC Active/Standby Protection (cont.)
Cross-connect and clock unit
1
Service unit
3
Service signal
Service signal and clock signal
Service signal
Clock signal
• In the normal state
1
3
• In the switching state
Service unit
Cross-connect and clock unit
Cross-connect and clock unit
Clock signal
Service signal
Service signal Cross-connect and clock unit
Service signal and clock signal
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
Summary
Service and Equipment Protection Schemes Supported by the
OptiX RTN 600
1+1 HSB protection
1+1 SD protection
1+1 FD protection
SNCP protection
Cross-connect and clock unit 1+1 hot standby
HUAWEI TECHNOLOGIES CO., LTD.
www.huawei.com
Huawei Confidential
Security Level:internal use
Thank You
www.huawei.com