OPTICAL DISSOLVED OXYGEN ANALYZERendee-engineers.com/download/Dissolved Oxygen.pdf · OPTICAL...

4
1 OPTICAL DISSOLVED OXYGEN ANALYZER POWER TEST ALARM FN endee Protects your Plant & Personnel ENDEE WA-200 WAP WRC-201 OPTICAL TECHNOLOGY FOR OPTIMIZED MEASUREMENTS WITH DISSOLVED OXYGEN PROBE Optical Luminescence Technology No Calibration, No membrane, No electrolyte, No drift No cross sensitivity with pH 1-14, CO2, H2S, SO2 Real time temperature, salinity and pressure compensation Fast response sensor Body in stainless steel or Titatanium ASTM international method D888-05 and ISO 17289 compliance Compact, Strong and Light Digital technology (MODBUS RS 485) Optical Dissolved Oxygen measurement no flow requirements

Transcript of OPTICAL DISSOLVED OXYGEN ANALYZERendee-engineers.com/download/Dissolved Oxygen.pdf · OPTICAL...

Page 1: OPTICAL DISSOLVED OXYGEN ANALYZERendee-engineers.com/download/Dissolved Oxygen.pdf · OPTICAL DISSOLVED OXYGEN ANALYZER POWER TEST ALARM FN endee Protects your Plant & Personnel ENDEE

1

OPTICAL DISSOLVED OXYGEN

ANALYZER

POWER TEST ALARM

FN

endeeProtects your Plant & Personnel

ENDEE

WA-200 WAP WRC-201

OPTICAL TECHNOLOGY FOR OPTIMIZED MEASUREMENTS

WITH DISSOLVED OXYGEN PROBE

Optical Luminescence Technology

No Calibration, No membrane, No electrolyte, No drift

No cross sensitivity with pH 1-14, CO2, H2S, SO2

Real time temperature, salinity and pressure compensation

Fast response sensor

Body in stainless steel or Titatanium

ASTM international method D888-05 and ISO 17289 compliance

Compact, Strong and Light

Digital technology (MODBUS RS 485)

Optical Dissolved Oxygen measurement no flow requirements

Page 2: OPTICAL DISSOLVED OXYGEN ANALYZERendee-engineers.com/download/Dissolved Oxygen.pdf · OPTICAL DISSOLVED OXYGEN ANALYZER POWER TEST ALARM FN endee Protects your Plant & Personnel ENDEE

2

SPECIAL FEATURES

Simple System Integration

Graphic LCD - Quick, Reliable System Status Checks

No Mechanically Moving Parts

Fast Response Time

Accurate Monitoring

Minimal maintenance

Field Replacement Sensor

Internal Datalogger

SPECIFICATIONS

Model No.

Type

Parameters

Electronics / processor

Technology

Power supply

Display

Alarm

Response time

Operating temperature

Input

Output

Housing

Indication LED

Power consumption

Dimensions

Protection class

Weight

WRC-201

Panel mounting

Dissolved Oxygen

Micro-controller

Optical / Luminescence

230 V AC

Graphic LCD

Visual LED alarms, adjustable

Instantaneous

0°C - 55°C

RS 485, MODBUS

RS 485, 4-20 mA

ABS Hi-Impact Plastic

Power ON, Test, High alarm

< 5 Watt

96 x 96 x 160 mm

IP 65

600 gm

WA-200

Wall mounting

Dissolved Oxygen

Micro-controller

Optical / Luminescence

230VAC, 50Hz

Graphic LCD

Visual LED alarms, adjustable

Instantaneous

0°C - 55ºC

RS 485, MODBUS

RS 485, 4-20 mA

ABS Hi-Impact Plastic

Power ON, Test, High alarm

< 5 Watt

270 x 240 x 150 (LBH)

IP 65

1.7 Kg

WAP

Portable

Dissolved Oxygen

Micro-controller

Optical / Luminescence

Rechargeable battery

Graphic LCD

Visual, audible

<1s

0°C - 50ºC

RS 485, Direct Plug-in

USB, Datalogging

ABS Hi-Impact Plastic

LOW, HIGH

< 5 Watt

200 x 94 x 37.5 mm

IP 65

330 gm

CONTROLLERHANDHELD

CONTROLLER CONTROLLER

Page 3: OPTICAL DISSOLVED OXYGEN ANALYZERendee-engineers.com/download/Dissolved Oxygen.pdf · OPTICAL DISSOLVED OXYGEN ANALYZER POWER TEST ALARM FN endee Protects your Plant & Personnel ENDEE

3

APPLICATIONS

Oil ,Food ,Chemical Industries

Municipal Water Treatment

Boiler Feed Water

Oil Refineries

Food Processing Wash Water

Raw Water Plants

Environmental Monitoring

Monitoring of UV-Disinfection in Water Plants

Sewage Treatment Plants

Drinking Water Plant

SENSOR CONTROLLER ARRANGEMENT

ENDEE

Page 4: OPTICAL DISSOLVED OXYGEN ANALYZERendee-engineers.com/download/Dissolved Oxygen.pdf · OPTICAL DISSOLVED OXYGEN ANALYZER POWER TEST ALARM FN endee Protects your Plant & Personnel ENDEE

ENDEE ENGINEERS PVT. LTD.Office : N/25, Laxmi Industrial Estate, New Link Road, Andheri (W), Mumbai - 400 053.

Tel. : 022 4295 2180 / 81

Email : [email protected]

Website : www.endee-engineers.com

Note : Images shown are indica�ve only. Specifica�ons and Features will vary with applica�on. There may be changes over�me due to con�nuous development process.

@ 2018

4

Measuring Principle

Measure Ranges

Resolution

Accuracy

Response time

Frequency of recommended measure

Water move

Temperature compensation

Stocking temperature

Sensor power supply

Consumption

Sensor

Dimensions

Weight

Material

Maximum pressure

Connection

Protection

Optical measure by luminescence

0-20 mg/l, 0-20 PPM, 0-200 %

0.01

± 0.1 mg/l, ±0.1 PPM, ± 1%

90% of the value in less than 60 seconds

> 5 second

No necessary move

Via NTC

-10°C to +60°C

5 to 12 volts

Standby 25 μA

Average RS-485 (1 measure / seconds)

Average SD112 (1 measure / seconds)

Current pulse : 100 mA

Diameter: 25mm, length: 146mm

Stainless steel version 300g (sensor + cable 3m)

Titanium version 300g (sensor + cable 3m)

Stainless steel 316 L, New body in titanium

5 bars

9 armoured connectors, polyurethane jacket, barewires

or waterproof fisher connector

IP 68

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

SENSOR SPECIFICATIONS

ORDERING INFORMATION

MODEL NO.

WA-200

WAP

WRC-201

RANGE

A. 0 - 20 mg/l

B. 0 - 20 PPM

C. 0 - 200 %

CABLE LENGTH

1. 3 meter

2. 7 meter

3. 15 meter

4. Beyond 15meter

Eg: WA-200 Dissolved Oxygen A. 0 - 20 mg/l 3. 15 meter

SENSOR /

PARAMETERS