OPTEVA 500 LOBBY CASH DISPENSER REAR LOAD...OPTEVA 500 LOBBY CASH DISPENSER REAR LOAD 4 HIGH WITH...
Transcript of OPTEVA 500 LOBBY CASH DISPENSER REAR LOAD...OPTEVA 500 LOBBY CASH DISPENSER REAR LOAD 4 HIGH WITH...
R
CALL 1-800-999-3600
THIR
D
AN
GL
E
PR
OJ
EC
TIO
N
DIM
EN
SIO
NS IN
MIL
LIM
ET
RES
"AL
L
DIM
EN
SIO
NS
AN
D
DESIG
N
CRIT
ERIA
SU
BJ
EC
T
TO
CH
AN
GE
WIT
HO
UT
NO
TIC
E."
PA
GE 1 O
F 4
L732520
FIL
E
NO. 17
7-520
RE
V. 1
( DIM
EN
SIO
NS IN IN
CH
ES )
00
0 0
0 0
00
PLAN VIEW
0
0 0
0
0
0 00
FRONT VIEW SIDE VIEW
0 0
470 ( 18�")
0 0
445 ( 17�")
0 0
000
CONSULT WITH DIEBOLD INSTALLATION/SERVICE
BRANCH FOR ADDITIONAL DETAILS AND INFORMATION.
PLEASE SEE PLANNING AND SITE PREPARATION GUIDE
TP-821233-001 PD 6319.
R
0
0
0
0 0
0
000
A
D
B
C
TOP
FUNCTION
KEY
ADVANCED
FUNCTION
DISPENSER
HEIGHT DEPTH HEIGHT DEPTH HEIGHT DEPTH
171
(6�")
HEIGHT DEPTH
HEIGHT - FROM BOTTOM OF SAFE
DEPTH - FROM FRONT EDGE OF BEZEL
RECEIPT
PRINTER
1 1 12
(43�")
A B C D
1008
(39�")
1 126
(44�")
5
(�")
100
(3�")
800
(31 �")
AIR INTAKE
00
E
00
F
E F
DEPTHDEPTHHEIGHT HEIGHT
CARD
READER
68
(2�")
AIR INTAKE
AIR INTAKE
AIR EXHAUST
NOTE:
HEADPHONE
JACK (ADA)
HEADPHONE
JACK (CSA)
963
(37�")
60
(2�")
1 189
(46�")
100
(3�")
00
0
603 (2
3�
")
733 (2
8�")
130
(5�
")
445 (17�")
470 (18�")
13 (�") 13 (�")
0 0
470 (18�")
DO NOT OBSTRUCT OR RESTRICT THE CASH DISPENSER VENTILATION HOLES IN
ANY WAY, INCLUDING (BUT NOT LIMITED TO) PLACING THE CASH DISPENSER TOO
CLOSE TO OTHER OBJECTS OR INSTALLING ADDITIONAL EQUIPMENT OR SIGNAGE
OVER THE VENTILATION HOLES.
0
0
00
31 (1�
")
30 (1�
")
40 (1�
")
1373 (5
4�
")
1272 (5
0�
")
00 0 0
00
733 (28�")
603 (23�")130
(5�")
390 (15�")102
(4")
111 (4�")
0
889 (3
5")
610 (24")
0
484 (1
9�
")
OPTEVA 500 LOBBY CASH DISPENSER
REAR LOAD
4 HIGH WITH 13mm (�") SAFE
1342 (5
2�
")
1373 (5
4�
")
0mm TO 76mm (0" TO 3") LEVELING
THIR
D
AN
GL
E
PR
OJ
EC
TIO
N
DIM
EN
SIO
NS IN
MIL
LIM
ET
RES
"AL
L
DIM
EN
SIO
NS
AN
D
DESIG
N
CRIT
ERIA
SU
BJ
EC
T
TO
CH
AN
GE
WIT
HO
UT
NO
TIC
E."
PA
GE 2
OF 4
FIL
E
NO. 17
7-520
RE
V. 1
( DIM
EN
SIO
NS IN IN
CH
ES )
1
1
PROVIDE FLAT COVER WITH TAMPER SWITCH.
1 mm
mm mm
mm mm
mm
mm
mm
E.C. TO SUPPLY COMPATIBLE RECEPTACLE FOR COUNTRY SPECIFIC PLUG-IN
NOTE:
ALARM PROTECTION
PHYSICAL SECURITY
WEIGHT OF UNIT
POWER REQUIREMENTS
SAFE LOCATION
OPERATING ENVIRONMENT
HEAT OUTPUT
200-240 VAC (+/-10%) 50Hz (+/-1%) SINGLE PHASE
100-127 VAC (+6%,-10%) 50Hz (+/-1%) SINGLE PHASE
100-127 VAC (+6%,-10%) 60Hz (+/-1%) SINGLE PHASE
200-240 VAC (+/-10%) 60Hz (+/-1%) SINGLE PHASE
RELATIVE CARE IS REQUIRED WHEN INSTALLING SIGNAL CABLES IN CONDUITS. UNLIKE POWER AND
POWER OF ELECTRICAL RUN
TYPE OF ELECTRICAL RUN
UNSHIELDED POWER LINE OR ELECTRICAL EQUIPMENT
LIGHTING CABLE, SIGNAL CABLES HAVE SMALL CONDUCTORS AND LIGHT INSULATION AND WILL NOT
BELOW 2 KVA 2-5 KVA ABOVE 5 KVA
THE FOLLOWING CHART ITEMIZES THE PHYSICAL SPACING REQUIREMENTS OF THE SIGNAL CABLE RUN
WITH RESPECT TO OTHER POWER AND ELECTRICAL EQUIPMENT CABLE RUN.
127mm (5") 127mm (5") 127mm (5")
305mm (12")
305mm (12")
610mm (2’-0")
64mm (2�") 152mm (6")
152mm (6")76mm (3")30mm (1�")
127mm (5")
FLUORESCENT, NEON OR INCANDESCENT
LIGHTING FIXTURES
POWER LINES IN GROUNDED CONDUIT WITH SIGNAL
CABLES IN GROUNDED CONDUIT
UNSHIELDED POWER LINES OR ELECTRICAL EQUIPMENT
WITH SIGNAL CABLES ENCLOSED IN GROUNDED CONDUIT
MACHINE STATUS
IDLE (NO TRANSACTION)
1
1
1
CONDUIT AND JUNCTION BOX
REQUIREMENTS
E.C. TO RUN 19 (�") LIQUID TIGHT FLEX METAL CONDUIT OR 19 (�") RIGID
CONDUIT FROM JUNCTION BOX TO CABLE CONNECTING PLATE.
BOXES CAN BE FLUSH MOUNTED WITH CONCEALED CONDUIT FOR
NEW CONSTRUCTION OR BOXES CAN BE SURFACE MOUNTED
WITH EXPOSED CONDUIT FOR EXISTING CONSTRUCTION.
THE UL-LISTED SAFE IS EQUIPPED WITH A BASIC ALARM SENSOR PACKAGE. THE
BASIC PACKAGE INCLUDES A SAFE DOOR OPEN SWITCH, ALARM SHUNTING SWITCH,
AND RATE-OF-RISE HEAT SENSOR.
THE SECURITY SAFE MEETS THE BANK PROTECTION ACT 82 STAT 295,
12 USC 882, AND MEETS THE ATTACK TEST PER UL 291-15. THE SAFE DOOR
HAS A POSITIVE RELOCKING FEATURE. THE SAFE DOOR IS CONTROLLED BY A
GROUP 2 COMBINATION LOCK WITH OR WITHOUT KEYLOCKING DIAL CAPABILITY
OR OPTIONAL ELECTRONIC LOCK.
25 ( 1") METAL CONDUIT FROM ALARM CONTROL CABINET JUNCTION BOX TO
102 (4") SQ. X 54 (2�") DP. JUNCTION BOX ( ALL BY E.C. ) DIEBOLD TO
100-127 VAC (+6%, -10%) SERVICE, DISCONNECT AT 20 AMPERES
200-240 VAC (~10%) SERVICE, DISCONNECT AT 10 AMPERES
THE MODULE BULK POWER SUPPLY AND PROCESSOR POWER SUPPLY WILL PROVIDE
POWER CONDITIONING TO PREVENT THE TERMINAL FROM MALFUNCTIONING DUE TO
SHORT-TERM AC POWER FLUCTUATIONS AS OUTLINED IN EN6100-4-11.
210 WATTS
290 WATTS
CONFIGURATION
WITHSTAND AS MUCH STRAIN IN INSTALLATION.
CONFIGURATION
TRANSACTION (DISPENSE
IN PROGRESS)
990 BTU/HR DISPENSING
THE CASH DISPENSER REQUIRES A SINGLE-PHASE, THREE-WIRE UNSWITCHED POWER
RECEPTACLE. WIRING TO THE RECEPTACLE MUST INCLUDE A THIRD-WIRE EARTH GROUND
(CONDUIT GROUND IS NOT ACCEPTABLE). THE CASH DISPENSER WILL PROVIDE A POWER
CORD WITH A COUNTRY SPECIFIC POWER PLUG. THE POWER SUPPLIED MUST BE AS
SPECIFIED BELOW.
POWER TO THE CASH DISPENSER MUST BE PROTECTED BY A SAFETY QUICK-
DISCONNECT DEVICE TO BREAK LINE VOLTAGE (SUCH AS A CIRCUIT BREAKER AT
THE ELECTRICAL SERVICE PANEL. THE QUICK-DISCONNECT DEVICE (OR CIRCUIT
BREAKER) MUST TURN OFF THE LINE VOLTAGE AT THE FOLLOWING AMPERAGE.
POWER USAGE
THE POWER USE DEPENDS ON THE NUMBER AND TYPE OF DEVICES PRESENT IN THE
CASH DISPENSER, AND THE TYPE OF TRANSACTION THE CASH DISPENSER IS PERFORMING.
SIGNAL CABLE RUN CONSTRAINTS
CONNECTOR SUPPLIED WITH UNIT. POWER CORD LENGTH 2210mm (87")
FROM SIDE OF UNIT.
JUNCTION BOXES MUST BE LOCATED WITHIN 2210mm (87") OF CONNECTING
PLATE. ( LENGTH OF ELECTRICAL POWER CABLE PROVIDED WITH UNIT).
LOCATE IN AN EASILY ACCESSIBLE AREA.
SIGNAL CABLE INSTALLATION CONSTRAINTS
(ALL BY E.C.) (SEE POWER REQUIREMENTS).
19 (�") METAL CONDUIT AND UNSWITCHED ELECTRICAL SUPPLY TO 102 (4") SQ.
X 54 (2�") DP. JUNCTION BOX WITH RECEPTACLE WITHIN 2210mm (87") OF
SIDE CONNECTING PLATE. BOTTOM CONNECTION MUST BE COMPENSATED ACCORDINGLY
BACK VIEW SIDE VIEW
10 C TO 40 C (50 F TO 104 F)
RELATIVE HUMIDITY ( NON-CONDENSING )
20 TO 80% AT 32 C (90 F),
20 TO 55% AT 38 C ( 100 F)
PROCESSOR, COLOR LCD CONSUMER DISPLAY, MOTORIZED CARD READER,
RECEIPT PRINTER, AND 4 HIGH AFD.
0000
143
(5�")
429 (16�")
38 (1�")
2
2
3
4
3
3
4
AIR EXHAUST
AIR INTAKE
00
0
POWER CORD
000000
350 (13�")
80 (3�")40 (1�")68 (2�")
603 (23�")
0 0
65(2�")
130
(5�")
00
733 (28�")
0
000
80 (3�
")20 (�
")
20
(�")
AIR INTAKE
0 0 0 0 0 0
0 0
445 (17�")
139
(5�")
139
(5�")
51 (2") 57 (2�")59 (2�")
00
000
0 00 0
337 (13�")
54 (2�") 54 (2�")360 (1
4�
")
40 (1�
")40 (1�
")3 (�
")
391 kg ( 862 LBS.)
718 BTU/HR IDLE
NOISE OUTPUT
OPERATING MODE LESS THAN 60 DECIBELS
IDLING MODE LESS THAN 55 DECIBELS
100 (3�")
"AL
L
DIM
EN
SIO
NS
AN
D
DESIG
N
CRIT
ERIA
SU
BJ
EC
T
TO
CH
AN
GE
WIT
HO
UT
NO
TIC
E."
THIR
D
AN
GL
E
PR
OJ
EC
TIO
N
DIM
EN
SIO
NS IN
MIL
LIM
ET
RES
R
CALL 1-800-999-3600
PA
GE 3
OF 4
FIL
E
NO. 17
7-520
RE
V. 1
( DIM
EN
SIO
NS IN IN
CH
ES )
MINIMUM SERVICE AREA
RECOMMENDED SERVICE AREA
ALL ELECTRICAL AND DATA CABLES
MUST ENTER UNIT IN THIS AREA
R
SIDE VIEW
PLAN VIEW ( SINGLE UNIT )
( MINIMUM SERVICE AREA )
0
VA
RIE
S
INSTALLATION/SERVICE AREA
DIMENSION SHOULD ALLOW FOR A
PERSON STANDING DURING INSTALLATION
AND SERVICING OF UNIT.
OPTEVA 500 LOBBY CASH DISPENSER
REAR LOAD
4 HIGH WITH 13mm (�") CHEST
51
(2")
0
00
0
00 00
0 0
89 (3�")89 (3�")
216
(8�")
254
(10")470 (18�")
940 (37")
0
0
0
0
0
0
0
00
0
0
676 (2
6�")
152
(6")
86 (3�")
733 (2
8�")
597 (2
3�
")
813 (32")
2006 (7
9")
NOTE:
SHOWN IS THE MINIMUM/RECOMMENDED AREA REQUIRED FOR INSTALLATION AND
SERVICE. DIMENSIONS SHOWN MAY BE INCREASED WHEREVER POSSIBLE TO
IMPROVE INSTALLATION AND SERVICE ACCESS. USE OF ANY AREA LESS THAN THE
RECOMMENDED AREA MAY RESULT IN AN INCREASE IN INSTALLATION AND SERVICE
TIME. CONSULT WITH DIEBOLD INSTALLATION/SERVICE BRANCH FOR SPECIAL
BUILDING CONDITIONS.
51
(2")
0
00
0 0 0
0
0
0
0
0
0
0
00
0
0
676 (2
6�")
152
(6")
86 (3�")
733 (2
8�")
847 (3
3�
")
404 (15�")366 (14�")
1240 (48�")
2256 (8
8�
")
PLAN VIEW ( SINGLE UNIT )
( RECOMMENDED SERVICE AREA )
00
00
0
102 (4
")
1444 (5
6�
")
0000
0 0 0
00
733 (28�") 676 (26�")597 (23�")
2006 (79")250
( 9�")
2256 (88�")
470 (18�")
1240 (48�")
1342 (5
2�
")
"AL
L
DIM
EN
SIO
NS
AN
D
DESIG
N
CRIT
ERIA
SU
BJ
EC
T
TO
CH
AN
GE
WIT
HO
UT
NO
TIC
E."
THIR
D
AN
GL
E
PR
OJ
EC
TIO
N
DIM
EN
SIO
NS IN
MIL
LIM
ET
RES
PA
GE 4
OF 4
FIL
E
NO. 17
7-520
RE
V. 1
( DIM
EN
SIO
NS IN IN
CH
ES )
0
0
VIEW "B"
0
0102 (4
")MIN.
OWNER’S INSTALLER TO DRILL (4) 19mm (�") DIA. X 203mm (8" MIN.) DEEP HOLES
IN CONCRETE FLOOR (RECOMMENDED DRILLING COMPLETELY THROUGH FLOOR
WHEN POSSIBLE AND TO BE SECURED TO THE CONCRETE FLOOR WITH (4)
19mm (�")-10 X 203mm (8") LONG WEDGE ANCHORS (SUPPLIED BY OWNER’S INSTALLER)
DIEBOLD PART NUMBER 29-016376-000A, HILTI PART NUMBER 282520).
MINIMUM HOLE DEPTH
203mm (8")
MINIMUM CONCRETE DEPTH
102mm (4")
VIEW "A"
203 (8
") M
IN.
(MINIMUM SERVICE AREA)
0 0
89 (3�")
445 (17�")445 (17�")445 (17�")
0
0
0
0
0 0 0 0 0 0 0 0 0
0
0
00750 (29�") 750 (29�")
305
(12")
305
(12")
165
(6�")
476 (18�")
89 (3�")127 (5")
438 (17�")
2414 (95")
0
0
0
0
0
0
676 (2
6�")
733 (2
8�")
597 (2
3�
")
2006 (7
9")
2286 (90")
676 (2
6�")
86 (3�")
152
(6")
0
0
0
0
PLAN VIEW-ADJACENT UNITS
0000
00
0
000
PLAN/SECTION
1
2
(4) 14 (�") DIA. LEVELING LEG HOLES
(4) 22 (�") DIA. FLOOR MOUNTING HOLES36 (1�
")
38 ( 1 �
")
373 (14�")
445 (17�") SAFE
36 (1�")36 (1�")
11
11
22
2 2
143
(5�
")SEE NOTE 2
0
00
00
00
98 (3�
")
454 ( 17�
")
421 ( 16�
")
000
90 (3�
")
609 (2
4") S
AF
E
428 ( 16�
")
120
(4�
")
NOTES:
POWER CABLE PLATE
29 ( 1 �") DIA. HOLE FOR
ALARM CABLES (SIDE ENTRY)
OPENING FOR POWER CORD
AND DATA CABLES
(SIDE ENTRY)
ELECTRICAL AND DATA CABLING ENTERS THE CASH DISPENSER
THROUGH A CABLE ENTRY OPENING ON THE SIDE OF THE SAFE.
CABLES ENTERING THE CASH DISPENSER PASS THROUGHTHE
POWER CABLE PLATE WHICH IS ATTACHED TO THE INSIDE WALL
OF THE SAFE OVER THE CABLE ENTRY OPENING. CABLING CAN
ENTER FROM THE SIDE OR OPTIONALLY FROM UNDER THE CASH
DISPENSER. THE CABLE ENTRY OPENING IS ON THE LEFT SIDE
OF THE SAFE AS VIEWED FROM THE FRONT OF THE CASH
DISPENSER.
FOR ADDED SECURITY:
IT IS RECOMMENDED THAT THE CASH DISPENSER SAFE BE SECURED TO THE FLOOR WITH
ANCHOR BOLTS. USE THE FOLLOWING GUIDELINES TO DETERMINE THE APPROPRIATE METHOD FOR
YOUR INSTALLATION.
ANCHORING THE CASH DISPENSER TO CONCRETE FLOORS:
IT IS RECOMMENDED THAT THE CASH DISPENSER BE ANCHORED TO CONCRETE FLOORS
WHENEVER POSSIBLE. DIEBOLD RECOMMENDS USING A M20 OR 19mm (�") ANCHOR BOLT THAT
IS 203mm (8") LONG. CONCRETE FLOORS OR CONCRETE BASES MUST BE A MINIMUM OF 102mm
(4") THICK FOR ANCHORING TO BE EFFECTIVE. THERE IS NO LIMIT FOR MAXIMUM THICKNESS.
ANCHOR BOLTS MUST BE USED IN ALL AVAILABLE ANCHOR HOLES. IF THE TERMINAL IS
EQUIPPED WITH LEGS, THE LEVELING LEGS MUST BE REMOVED BEFORE THE TERMINAL IS
ANCHORED. REFER TO VIEW "A" AND "B" FOR ADDITIONAL DETAILS.
ANCHORING THE CASH DISPENSER TO WOOD FLOORING:
CASH DISPENSERS INSTALLED ON WOOD FLOORS OR FLOORS SUPPORTED BY WOODED BEAMS
CAN BE SECURED BY A MACHINE-THREADED NUT AND BOLT METHOD. IT IS PREFERRED THAT
THE HARDWARE BE ATTACHED THROUGH SUPPORTING POSTS OR BEAMS FOR MAXIMUM HOLDING
CAPACITY. ADDITIONALLY, THIS HARDWARE MUST ATTACH TO A LOCALLY FABRICATED
REINFORCEMENT PLATE INSTALLED UNDERNEATH THE FLOOR TO PROVIDE ADDITIONAL
STRENGTH. THE REINFORCEMENT PLATE IS TYPICALLY 6mm (�") THICK. IT IS IMPORTANT TO
NOTE THAT THE OVERALL HOLDING CAPACITY OF A WOOD FLOOR WILL BE LESS THAN THAT
OF CONCRETE FLOORS.
ANCHORING THE CASH DISPENSER TO STEEL FLOORS:
CASH DISPENSER INSTALLED ON STEEL FLOORS CAN BE SECURED BY A MACHINE-THREADED
METHOD. IT IS PREFERABLE THAT THE HARDWARE BE ATTACHED THROUGH SUPPORTING POSTS
OR BEAMS FOR MAXIMUM HOLDING CAPACITY. ADDITIONALLY, THIS HARDWARE MUST ATTACH TO
A LOCALLY FABRICATED REINFORCEMENT PLATE INSTALLED UNDERNEATH THE FLOOR TO
PROVIDE ADDITIONAL STRENGTH. THE COMBINED BACKING PLATE AND FLOOR THICKNESS MUST
BE AT LEAST 13mm (�").