OPSD 804.040 Headwall (Modified) · Precast Storm Water Products OPSD 804.040 Headwall (Modified)...

16
OPSD 804.040 Headwall (Modified)

Transcript of OPSD 804.040 Headwall (Modified) · Precast Storm Water Products OPSD 804.040 Headwall (Modified)...

Page 1: OPSD 804.040 Headwall (Modified) · Precast Storm Water Products OPSD 804.040 Headwall (Modified) Hy-Grade Precast Concrete | 2018 Water Product Catalogue 4 -675mm Ø UNIT WEIGHTS:

OPSD 804.040

Headwall (Modified)

Page 2: OPSD 804.040 Headwall (Modified) · Precast Storm Water Products OPSD 804.040 Headwall (Modified) Hy-Grade Precast Concrete | 2018 Water Product Catalogue 4 -675mm Ø UNIT WEIGHTS:

Precast Storm Water Products

Hy-Grade Precast Concrete | 2018 Water Product Catalogue 2

OPSD 804.040 Headwalls (Modified)

600 mm Ø ........................................................................................................................................................................ 3

675 mm Ø ........................................................................................................................................................................ 4

750 mm Ø ........................................................................................................................................................................ 5

825 mm Ø ........................................................................................................................................................................ 6

900 mm Ø ........................................................................................................................................................................ 7

975 mm Ø ........................................................................................................................................................................ 8

1050 mm Ø ...................................................................................................................................................................... 9

1200 mm Ø ...................................................................................................................................................................... 10

1350 mm Ø ...................................................................................................................................................................... 11

1500 mm Ø ...................................................................................................................................................................... 12

1650 mm Ø ...................................................................................................................................................................... 13

1800 mm Ø ...................................................................................................................................................................... 14

2400 mm Ø ...................................................................................................................................................................... 15

Table of Contents

Page 3: OPSD 804.040 Headwall (Modified) · Precast Storm Water Products OPSD 804.040 Headwall (Modified) Hy-Grade Precast Concrete | 2018 Water Product Catalogue 4 -675mm Ø UNIT WEIGHTS:

Precast Storm Water Products

Hy-Grade Precast Concrete | 2018 Water Product Catalogue 3

OPSD 804.040 Headwall (Modified) - 600mm Ø

UNIT WEIGHTS:

Footing A - 2993 kg

Footing B - 4190 kg

Footing C - 4190 kg

Footing D - 1701 kg

Slab - 2884 kg

Wing Wall A - 1276 kg

Wing Wall B – 1276 kg

Upper Headwall - 992 kg

Lower Headwall - 992 kg

Total – 20 493 kg

REFERENCE STANDARDS: Precast Alternative to OPSD 804.040

Hand Rail to OPSD 980.101 (available upon request)

Grating to OPSD 804.050 (available upon request)

35 MPa concrete cured in accordance with CSA A23.4, normal curing

Reinforcing bars as per CAN/CSA G30.18, Grade 400W.

NOTES:

Ideal for pipe outlets discharging into open water courses.

Culvert Applications can also be accommodated upon special request.

All elements provided as precast including footings; no site forming/casting required.

Page 4: OPSD 804.040 Headwall (Modified) · Precast Storm Water Products OPSD 804.040 Headwall (Modified) Hy-Grade Precast Concrete | 2018 Water Product Catalogue 4 -675mm Ø UNIT WEIGHTS:

Precast Storm Water Products

Hy-Grade Precast Concrete | 2018 Water Product Catalogue 4

OPSD 804.040 Headwall (Modified) - 675mm Ø

UNIT WEIGHTS:

Footing A - 2993 kg

Footing B - 4190 kg

Footing C - 4190 kg

Footing D - 1701 kg

Slab - 2884 kg

Wing Wall A - 1335 kg

Wing Wall B – 1335 kg

Upper Headwall - 1010 kg

Lower Headwall - 1010 kg

Total – 20 648 kg

REFERENCE STANDARDS: Precast Alternative to OPSD 804.040

Hand Rail to OPSD 980.101 (available upon request)

Grating to OPSD 804.050 (available upon request)

35 MPa concrete cured in accordance with CSA A23.4, normal curing

Reinforcing bars as per CAN/CSA G30.18, Grade 400W.

NOTES:

Ideal for pipe outlets discharging into open water courses.

Culvert Applications can also be accommodated upon special request.

All elements provided as precast including footings; no site forming/casting required.

Page 5: OPSD 804.040 Headwall (Modified) · Precast Storm Water Products OPSD 804.040 Headwall (Modified) Hy-Grade Precast Concrete | 2018 Water Product Catalogue 4 -675mm Ø UNIT WEIGHTS:

Precast Storm Water Products

Hy-Grade Precast Concrete | 2018 Water Product Catalogue 5

OPSD 804.040 Headwall (Modified) - 750mm Ø

UNIT WEIGHTS:

Footing A - 2993 kg

Footing B - 4190 kg

Footing C - 4190 kg

Footing D - 1701 kg

Slab - 2884 kg

Wing Wall A - 1395 kg

Wing Wall B – 1395 kg

Upper Headwall - 1022 kg

Lower Headwall - 1022 kg

Total – 20 792 kg

REFERENCE STANDARDS: Precast Alternative to OPSD 804.040

Hand Rail to OPSD 980.101 (available upon request)

Grating to OPSD 804.050 (available upon request)

35 MPa concrete cured in accordance with CSA A23.4, normal curing

Reinforcing bars as per CAN/CSA G30.18, Grade 400W.

NOTES:

Ideal for pipe outlets discharging into open water courses.

Culvert Applications can also be accommodated upon special request.

All elements provided as precast including footings; no site forming/casting required.

Page 6: OPSD 804.040 Headwall (Modified) · Precast Storm Water Products OPSD 804.040 Headwall (Modified) Hy-Grade Precast Concrete | 2018 Water Product Catalogue 4 -675mm Ø UNIT WEIGHTS:

Precast Storm Water Products

Hy-Grade Precast Concrete | 2018 Water Product Catalogue 6

OPSD 804.040 Headwall (Modified) - 825mm Ø

UNIT WEIGHTS:

Footing A - 2993 kg

Footing B - 4190 kg

Footing C - 4190 kg

Footing D - 1701 kg

Slab - 2884 kg

Wing Wall A - 1455 kg

Wing Wall B – 1455 kg

Upper Headwall - 1029 kg

Lower Headwall - 1029 kg

Total – 20 925 kg

REFERENCE STANDARDS: Precast Alternative to OPSD 804.040

Hand Rail to OPSD 980.101 (available upon request)

Grating to OPSD 804.050 (available upon request)

35 MPa concrete cured in accordance with CSA A23.4, normal curing

Reinforcing bars as per CAN/CSA G30.18, Grade 400W.

NOTES:

Ideal for pipe outlets discharging into open water courses.

Culvert Applications can also be accommodated upon special request.

All elements provided as precast including footings; no site forming/casting required.

Page 7: OPSD 804.040 Headwall (Modified) · Precast Storm Water Products OPSD 804.040 Headwall (Modified) Hy-Grade Precast Concrete | 2018 Water Product Catalogue 4 -675mm Ø UNIT WEIGHTS:

Precast Storm Water Products

Hy-Grade Precast Concrete | 2018 Water Product Catalogue 7

OPSD 804.040 Headwall (Modified) - 900mm Ø

UNIT WEIGHTS:

Footing A - 2993 kg

Footing B - 4190 kg

Footing C - 4190 kg

Footing D - 1701 kg

Slab - 2884 kg

Wing Wall A - 1515 kg

Wing Wall B – 1515 kg

Upper Headwall - 1030 kg

Lower Headwall - 1030 kg

Total – 21 047 kg

REFERENCE STANDARDS: Precast Alternative to OPSD 804.040

Hand Rail to OPSD 980.101 (available upon request)

Grating to OPSD 804.050 (available upon request)

35 MPa concrete cured in accordance with CSA A23.4, normal curing

Reinforcing bars as per CAN/CSA G30.18, Grade 400W.

NOTES:

Ideal for pipe outlets discharging into open water courses.

Culvert Applications can also be accommodated upon special request.

All elements provided as precast including footings; no site forming/casting required.

Page 8: OPSD 804.040 Headwall (Modified) · Precast Storm Water Products OPSD 804.040 Headwall (Modified) Hy-Grade Precast Concrete | 2018 Water Product Catalogue 4 -675mm Ø UNIT WEIGHTS:

Precast Storm Water Products

Hy-Grade Precast Concrete | 2018 Water Product Catalogue 8

OPSD 804.040 Headwall (Modified) - 975mm Ø

UNIT WEIGHTS:

Footing A - 2993 kg

Footing B - 4190 kg

Footing C - 4190 kg

Footing D - 1701 kg

Slab - 2884 kg

Wing Wall A - 1574 kg

Wing Wall B – 1574 kg

Upper Headwall - 1026 kg

Lower Headwall - 1026 kg

Total – 21 158 kg

REFERENCE STANDARDS: Precast Alternative to OPSD 804.040

Hand Rail to OPSD 980.101 (available upon request)

Grating to OPSD 804.050 (available upon request)

35 MPa concrete cured in accordance with CSA A23.4, normal curing

Reinforcing bars as per CAN/CSA G30.18, Grade 400W.

NOTES:

Ideal for pipe outlets discharging into open water courses.

Culvert Applications can also be accommodated upon special request.

All elements provided as precast including footings; no site forming/casting required.

Page 9: OPSD 804.040 Headwall (Modified) · Precast Storm Water Products OPSD 804.040 Headwall (Modified) Hy-Grade Precast Concrete | 2018 Water Product Catalogue 4 -675mm Ø UNIT WEIGHTS:

Precast Storm Water Products

Hy-Grade Precast Concrete | 2018 Water Product Catalogue 9

OPSD 804.040 Headwall (Modified) - 1050mm Ø

UNIT WEIGHTS:

Footing A - 3953 kg

Footing B - 5065 kg

Footing C - 5065 kg

Footing D - 2386 kg

Slab - 4455 kg

Wing Wall A - 2040 kg

Wing Wall B – 2040 kg

Upper Headwall - 1351 kg

Lower Headwall - 1351 kg

Total – 27 706 kg

REFERENCE STANDARDS: Precast Alternative to OPSD 804.040

Hand Rail to OPSD 980.101 (available upon request)

Grating to OPSD 804.050 (available upon request)

35 MPa concrete cured in accordance with CSA A23.4, normal curing

Reinforcing bars as per CAN/CSA G30.18, Grade 400W.

NOTES:

Ideal for pipe outlets discharging into open water courses.

Culvert Applications can also be accommodated upon special request.

All elements provided as precast including footings; no site forming/casting required.

Page 10: OPSD 804.040 Headwall (Modified) · Precast Storm Water Products OPSD 804.040 Headwall (Modified) Hy-Grade Precast Concrete | 2018 Water Product Catalogue 4 -675mm Ø UNIT WEIGHTS:

Precast Storm Water Products

Hy-Grade Precast Concrete | 2018 Water Product Catalogue 10

UNIT WEIGHTS:

Footing A - 3953 kg

Footing B - 5065 kg

Footing C - 5065 kg

Footing D - 2386 kg

Slab - 4455 kg

Wing Wall A - 2157 kg

Wing Wall B – 2157 kg

Upper Headwall - 1347 kg

Lower Headwall - 1347 kg

Total – 27 932 kg

REFERENCE STANDARDS: Precast Alternative to OPSD 804.040

Hand Rail to OPSD 980.101 (available upon request)

Grating to OPSD 804.050 (available upon request)

35 MPa concrete cured in accordance with CSA A23.4, normal curing

Reinforcing bars as per CAN/CSA G30.18, Grade 400W.

NOTES:

Ideal for pipe outlets discharging into open water courses.

Culvert Applications can also be accommodated upon special request.

All elements provided as precast including footings; no site forming/casting required.

OPSD 804.040 Headwall (Modified) - 1200mm Ø

Page 11: OPSD 804.040 Headwall (Modified) · Precast Storm Water Products OPSD 804.040 Headwall (Modified) Hy-Grade Precast Concrete | 2018 Water Product Catalogue 4 -675mm Ø UNIT WEIGHTS:

Precast Storm Water Products

Hy-Grade Precast Concrete | 2018 Water Product Catalogue 11

OPSD 804.040 Headwall (Modified) - 1350mm Ø

UNIT WEIGHTS:

Footing A - 3953 kg

Footing B - 5065 kg

Footing C - 5065 kg

Footing D - 2386 kg

Slab - 4455 kg

Wing Wall A - 2338 kg

Wing Wall B – 2338 kg

Upper Headwall - 1315 kg

Lower Headwall - 1315 kg

Total – 28 229 kg

REFERENCE STANDARDS: Precast Alternative to OPSD 804.040

Hand Rail to OPSD 980.101 (available upon request)

Grating to OPSD 804.050 (available upon request)

35 MPa concrete cured in accordance with CSA A23.4, normal curing

Reinforcing bars as per CAN/CSA G30.18, Grade 400W.

NOTES:

Ideal for pipe outlets discharging into open water courses.

Culvert Applications can also be accommodated upon special request.

All elements provided as precast including footings; no site forming/casting required.

Page 12: OPSD 804.040 Headwall (Modified) · Precast Storm Water Products OPSD 804.040 Headwall (Modified) Hy-Grade Precast Concrete | 2018 Water Product Catalogue 4 -675mm Ø UNIT WEIGHTS:

Precast Storm Water Products

Hy-Grade Precast Concrete | 2018 Water Product Catalogue 12

OPSD 804.040 Headwall (Modified) - 1500mm Ø

UNIT WEIGHTS:

Footing A - 4591 kg

Footing B - 5065 kg

Footing C - 5065 kg

Footing D - 3206 kg

Slab - 5184 kg

Wing Wall A - 2455 kg

Wing Wall B – 2455 kg

Upper Headwall - 1778 kg

Lower Headwall - 1778 kg

Total – 31 578 kg

REFERENCE STANDARDS: Precast Alternative to OPSD 804.040

Hand Rail to OPSD 980.101 (available upon request)

Grating to OPSD 804.050 (available upon request)

35 MPa concrete cured in accordance with CSA A23.4, normal curing

Reinforcing bars as per CAN/CSA G30.18, Grade 400W.

NOTES:

Ideal for pipe outlets discharging into open water courses.

Culvert Applications can also be accommodated upon special request.

All elements provided as precast including footings; no site forming/casting required.

Page 13: OPSD 804.040 Headwall (Modified) · Precast Storm Water Products OPSD 804.040 Headwall (Modified) Hy-Grade Precast Concrete | 2018 Water Product Catalogue 4 -675mm Ø UNIT WEIGHTS:

Precast Storm Water Products

Hy-Grade Precast Concrete | 2018 Water Product Catalogue 13

OPSD 804.040 Headwall (Modified) - 1650mm Ø

UNIT WEIGHTS:

Footing A - 4591 kg

Footing B - 5065 kg

Footing C - 5065 kg

Footing D - 3206 kg

Slab - 5184 kg

Wing Wall A - 2605 kg

Wing Wall B – 2605 kg

Upper Headwall - 1745 kg

Lower Headwall - 1745 kg

Total – 31 810 kg

REFERENCE STANDARDS: Precast Alternative to OPSD 804.040

Hand Rail to OPSD 980.101 (available upon request)

Grating to OPSD 804.050 (available upon request)

35 MPa concrete cured in accordance with CSA A23.4, normal curing

Reinforcing bars as per CAN/CSA G30.18, Grade 400W.

NOTES:

Ideal for pipe outlets discharging into open water courses.

Culvert Applications can also be accommodated upon special request.

All elements provided as precast including footings; no site forming/casting required.

Page 14: OPSD 804.040 Headwall (Modified) · Precast Storm Water Products OPSD 804.040 Headwall (Modified) Hy-Grade Precast Concrete | 2018 Water Product Catalogue 4 -675mm Ø UNIT WEIGHTS:

Precast Storm Water Products

Hy-Grade Precast Concrete | 2018 Water Product Catalogue 14

OPSD 804.040 Headwall (Modified) - 1800mm Ø

UNIT WEIGHTS:

Footing A - 4591 kg

Footing B - 5065 kg

Footing C - 5065 kg

Footing D - 3206 kg

Slab - 5184 kg

Wing Wall A - 2753 kg

Wing Wall B – 2753 kg

Upper Headwall - 1690 kg

Lower Headwall - 1690 kg

Total – 31 996 kg

REFERENCE STANDARDS: Precast Alternative to OPSD 804.040

Hand Rail to OPSD 980.101 (available upon request)

Grating to OPSD 804.050 (available upon request)

35 MPa concrete cured in accordance with CSA A23.4, normal curing

Reinforcing bars as per CAN/CSA G30.18, Grade 400W.

NOTES:

Ideal for pipe outlets discharging into open water courses.

Culvert Applications can also be accommodated upon special request.

All elements provided as precast including footings; no site forming/casting required.

Page 15: OPSD 804.040 Headwall (Modified) · Precast Storm Water Products OPSD 804.040 Headwall (Modified) Hy-Grade Precast Concrete | 2018 Water Product Catalogue 4 -675mm Ø UNIT WEIGHTS:

Precast Storm Water Products

Hy-Grade Precast Concrete | 2018 Water Product Catalogue 15

OPSD 804.040 Headwall (Modified) - 2400mm Ø

UNIT WEIGHTS:

Footing A - 5709 kg

Footing B - 5153 kg

Footing C - 5153 kg

Footing D - 4573 kg

Slab - 6555 kg

Wing Wall A - 3416 kg

Wing Wall B – 3416 kg

Upper Headwall - 2441 kg

Lower Headwall - 2441 kg

Total – 38 856 kg

REFERENCE STANDARDS: Precast Alternative to OPSD 804.040

Hand Rail to OPSD 980.101 (available upon request)

Grating to OPSD 804.050 (available upon request)

35 MPa concrete cured in accordance with CSA A23.4, normal curing

Reinforcing bars as per CAN/CSA G30.18, Grade 400W.

NOTES:

Ideal for pipe outlets discharging into open water courses.

Culvert Applications can also be accommodated upon special request.

All elements provided as precast including footings; no site forming/casting required.

Page 16: OPSD 804.040 Headwall (Modified) · Precast Storm Water Products OPSD 804.040 Headwall (Modified) Hy-Grade Precast Concrete | 2018 Water Product Catalogue 4 -675mm Ø UNIT WEIGHTS:

Hy-Grade Precast Concrete 2411 First Street Louth St.Catharines, Ontario L2R 6P7, Canada

Toll Free: 1 800 229 8568 Tel: 905 684 8568 Fax: 905 684 8560 hygradeprecast.com

CONTACT US TODAY TO EXPERIENCE THE HY-GRADE ADVANTAGE!