OPS-360 Operator Station User’s Guide Pulsar Version 5.1 Copyright © ECI Telecom 1998. All Rights Reserved. This manual may contain minor flaws, omissions or typesetting errors. Information contained herein is periodically updated and changes will be incorporated into subsequent editions. If you have encountered an error, please notify ECI Telecom. All specifications are subject to change without prior notice.

Transcript of OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by...

Page 1: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

OPS-360

Operator StationUser’s Guide

Pulsar Version 5.1

Copyright © ECI Telecom 1998. All Rights Reserved.

This manual may contain minor flaws, omissions or typesetting errors. Information contained herein isperiodically updated and changes will be incorporated into subsequent editions. If you have encountered anerror, please notify ECI Telecom. All specifications are subject to change without prior notice.

Page 2: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

CE MARK COMPLIANCE

The DTX-360 is marked with a CE Mark (see below). This mark has been affixed todemonstrate full product compliance with the following European directives:

a) Directive 73/23/EEC - Council Directive of 19/02/1973 on the harmonization of the lawsof Member States relating to electrical equipment designed for use within certain voltagelimits.

b) Directive 89/336/EEC - Council Directive of 3/05/1989 on the approximation of laws ofthe Member States relating to Electro-Magnetic Compatibility (EMC).

Issue date: 6 February 1996

This document contains proprietary information. It may not, in whole or in part, be published, used, orreproduced, nor may be disclosed to third parties without the express written permission of ECITelecom .

Copyright by ECI Telecom Ltd., 1997All rights reserved worldwide

ECI Telecom reserves the right, without notice, to make changes in equipment design orspecifications.

Information supplied by ECI Telecom is believed to be accurate and reliable. However, noresponsibility is assumed by ECI Telecom for its use nor for rights of third parties which mayresult from its use.

Any representations in this document concerning performance are for informational purposesonly and are not warranties of future performance, either express or implied. ECI Telecom ’sstandard limited warranty, stated in its sales contract or order confirmation form, is the onlywarranty offered by ECI Telecom .

Page 3: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

92050005-04 i

Table of ContentsChapter Page

1 OPS-360 - INTRODUCTION..........................................................................................1-1

OPS-360 System Functioning ....................................................................................1-1Monitoring the System.......................................................................................................1-2Configuring Maps..............................................................................................................1-2Producing Reports .............................................................................................................1-3

2 CONTROL PANEL ........................................................................................................2-1

General Description....................................................................................................2-1

Tool Icons ...................................................................................................................2-2Admin................................................................................................................................2-2Log In/Out .........................................................................................................................2-6Config Lib (Configuration Library)...................................................................................2-6Help (Context Sensitive)....................................................................................................2-6Exit ....................................................................................................................................2-6Site (Site Window Editor) .................................................................................................2-7

Message Field ............................................................................................................2-8

3 SOFTWARE INSTALLATION .......................................................................................3-1

General.......................................................................................................................3-1

Conventions Used in This Document .........................................................................3-2Preliminary Installation Steps............................................................................................3-2Installing the Software .......................................................................................................3-3Installing the Terminal Software (without the OPS) ...................................................................3-5

Page 4: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

OPS-360 USER’S GUIDE TABLE OF CONTENTS

ii 92050005-04

Storing Maps to Diskette/Hard Disk..................................................................................3-5Loading Maps from Diskette/Hard Disk............................................................................3-7Shutting Down the OPS and the SUN Workstation...........................................................3-8

4 CONFIGURATION MAP LIBRARY ...............................................................................4-1

Introduction.................................................................................................................4-1

The Map Library Window............................................................................................4-2

Editing a Configuration Map .......................................................................................4-7The Configuration Map Categories Window.....................................................................4-7How to Edit Parameters...................................................................................................4-10Configuration Map Categories.........................................................................................4-12

5 SITE AND CLUSTER WINDOW....................................................................................5-1

Site Window................................................................................................................5-1Cluster Menu .....................................................................................................................5-2Setup Menu........................................................................................................................5-3

Cluster Window ..........................................................................................................5-5Terminal Menu ..................................................................................................................5-9Lock Menu.......................................................................................................................5-17Maintenance Menu ..........................................................................................................5-20Map Menu .......................................................................................................................5-23Setup Menu......................................................................................................................5-29Tools Menu and Tool Icons.............................................................................................5-34

6 DATABASE FILES.........................................................................................................6-1

Introduction.................................................................................................................6-1File Management ...............................................................................................................6-1File Structure .....................................................................................................................6-1File Names.........................................................................................................................6-1File Contents......................................................................................................................6-2

A OMCP MONITOR REPORTS SESSION...................................................................... A-1

OMCP Monitor Reports Session on the OPS-360..................................................... A-1

Opening an OMCP Monitor Reports Session............................................................ A-2DTX-360 Reports Main Menu.......................................................................................... A-4Closing the OMCP Monitor Window............................................................................. A-32

Page 5: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

92050005-04 1-1

OPS-360 - Introduction

OPS-360 System FunctioningThe OPS-360 is the DTX-360 operator station, a SUN-based system designed toprovide the operator with state-of-the-art tools for managing the DTX-360.

The OPS-360 provides the following functions:

Fault Management - Alarm surveillance, event logging and display, fault location,and fault alert facilities.

Configuration Management - Manipulation of all aspects of the DTX-360.

Accounting Management - Produces reports as required.

Performance Management - Monitoring, control, and analysis of the concurrentcommissioning, operation and maintenance of multiple terminals.

Security Management - Authorization and authentication of users, audition ofoperator actions, access control management, and multiple-operator control.

The OPS-360 system enables you to perform the following tasks:

Monitoring the system, page 1-2

Configuring maps, page 1-2

Producing reports, page 1-3

Page 6: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

1-2 92050005-04

Monitoring the SystemMonitoring the system is the most frequently performed task on the OPS-360. TheOPS-360 is designed to help identify potential problems in the communication flowand prevent or solve them as quickly as possible, keeping telephone users satisfied.In order to identify potential problems throughout the system, the user must be ableto view and access information from the global level down to the most detailed levelwith flexibility and speed.

For this purpose, the OPS-360 displays the status of its components at all levels, asseen in:

The Control Panel which displays the highest alarm level of the site.

The Site Window which displays the status of each cluster at the site.

The Cluster window which displays the status of each terminal in the cluster. Fromthis window, additional information and controls are available to manage theDTX-360 terminals.

Configuring MapsIn the OPS-360 system, a map is a set of system parameters that determines how thelocal terminal will function facing a terminal in a remote site.

While map configuration is probably the least frequently performed task on the OPS-360, it may be the most critical one. Improper configuration – such as maps that arenot synchronized with the far end – may prevent the system from working. To avoidthis, parameters should be set in conjunction with the far end. Proper communicationflow is completely dependent on a correctly tuned "handshake" of the terminals onboth sides of the wire. The map defines this "handshake".

Page 7: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

92050005-04 1-3

For maintenance and protection purposes, maps are stored on three levels:

In the Map Library. All the maps, except the Background/Foreground maps, arestored here. Maps in the library may be edited and downloaded to any terminal asbackground maps.

As a background map stored in the terminal. The background map is a stand by map,ready for use when changed with the foreground map.

As a foreground map used by the terminal. The foreground map is stored in theterminal and used to determine how the terminal operates. To change the mapparameters, edit the background map and then change between foreground andbackground maps.

You can view and edit maps. If a given map is being edited by one user, it becomes"read-only" for other working OPS-360s in the network.

Producing ReportsYou can use the OPS-360 system to generate and produce various reports for:

Routine information such as traffic and system statistics.

Malfunction handling for listing and diagnosing problems.

Page 8: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

92050005-04 2-1

Control Panel

General DescriptionThe Control Panel is the starting point for all OPS-360 functions. It comprises thefull work routine involved in operating an OPS-360 system.

The two main functions of the Control Panel are:

To provide information regarding the most urgent alarms at the site

To provide access to OPS-360 tools such as the Configuration Map Library andAdmin

To provide access to other OPS-360 windows

The Control Panel opens automatically when the OPS-360 application starts, andcloses when you exit the application.

The Control Panel consists of:

A horizontal list of tool icons, page 2-2

A message field, page 2-8

2

Page 9: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 C O N T R O L P A N E L

92050005-042-2

Tool IconsTool icons are graphic symbols representing various tools, facilities, or functionsavailable to the user.

The available icons contained in the Control Panel, in this version, are:

Admin , see below

Log In/Out , see 2-6

Config Lib (Configuration Library) , page 2-6

Help (Context Sensitive Online Help), page 2-6

Exit , page 2-6

Site, page 2-7

Message Field, page 2-8

AdminThe Admin icon enables you to perform various administrative operations on theOPS. Click the Admin icon to open a dialog box with a list of the functionsavailable in this option.

The Admin dialog box offers the following options:

Page 10: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

C O N T R O L P A N E L O P S - 3 6 0

92050005-04 2-3

Login

Click to login to the OPS station. A dialog box opens. Enter your User Name andPassword in the fields provided. Click OK to login and Cancel to cancel the operation.

Logout

Click this option to logout. A confirmation window will open with the question: “Areyou sure you want to logout?” Click OK to logout and Cancel to cancel the operation.

Change Password

Click this option to change the password of the currently logged in user. A dialogbox will open, containing the following fields:

User Name - An uneditable field that indicates the currently logged in User Name

Current Password - Enter the password of the currently logged in user

New Password - Enter the user’s new password

Confirm Password - Enter the new password again

Click OK to change the password. Click Cancel to cancel the operation.

Show User Information

Click this option to display information regarding the selected user; including accesslevel. A dialog box will open, containing the following fields:

User Name - Indicates the name of the User

Access Level - Indicates the User’s access level (Administrator, Operator, etc.)

Terminals Access - Indicates the extent of the User’s access (Full or Selected NEs)

The Access Table appears below these fields. The terminal and cluster numbers aredisplayed in the rows and columns of this table. The User’s access to a particularterminal in a cluster is indicated by a check mark. All users may have access to allterminals. Operators may have access to all or selected terminals.

Click OK to continue and Cancel to cancel the operation.

Page 11: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 C O N T R O L P A N E L

92050005-042-4

Users Management

Click this option to display the access levels of all users at the site. A dialog box opensdisplaying a table of User Names and Access Levels. The buttons below allow anadministrator to Add, Delete or Modify a User Name or Access Level.

To Add a new User, select the User Name from the list and click Add. A dialog boxopens, containing the following fields:

New User Name - Enter the User Name of the new User.

New Password - Enter the password of the new User

Confirm Password - Enter the new password again

Access Level - Indicates the User’s access level (see the list of access levels on thefollowing page)

Terminals Access - Indicates the extent of the User’s access (Full or Selected NEs)

The Access Table appears below these fields. The terminal and cluster numbers aredisplayed in the rows and columns of this table. The User’s access to a particularterminal in a cluster is indicated by a check mark. All users may have access to allterminals. Operators may have access to all or selected terminals.

Click Select All to select all terminals listed in the table. Click Deselect All todeselect all terminals. These editing options are available only to administrators.

Click OK to add the new User. Click Cancel to cancel the operation.

To Delete a User Name, select the User Name from the list and click Delete.

To Modify a User’s password or access rights, select the User Name from the listand click Modify . A dialog box opens, containing the following fields:

User Name - An uneditable field that indicates the selected User Name

New Password - Enter the User’s new password

Confirm Password - Enter the new password again

Access Level - Indicates the User’s Access Level. Click the drop-down list tochange the User’s access level (see the list of access levels on the following page).

Terminals Access - Indicates the extent of the User’s access (Full or Selected NEs).Click the drop-down list to change the User’s access to the terminals.

Page 12: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

C O N T R O L P A N E L O P S - 3 6 0

92050005-04 2-5

The Access Table appears below these fields. The terminal and cluster numbers aredisplayed in the rows and columns of this table. The User’s access to a particularterminal in a cluster is indicated by a check mark. All users may have access to allterminals. Operators may have access to all or selected terminals.

Click Select All to select all terminals listed in the table. Click Deselect All todeselect all terminals.

Click OK to accept all changes. Click Cancel to cancel the operation.

Access Levels

Access rights are a set of pre-defined application features and operations which arenot user-definable. Access level assignment is a function of administrators only.

Administrators can assign the following access levels to users:

• Guest - A read-only access right. This mode allows the user to view events,terminal status and selected reports only. The site, cluster and events as wellas error performance and online reports may be viewed.

• Viewer - A read-only access right. This mode allows the user to viewevents, terminal status, configuration maps, etc. All reports andconfiguration maps may be viewed.

• Operator - The user has full access to a predefined set of clusters and/orterminals. The operator may carry out the following:

• Setup commands (Add/Remove Terminal/Cabinet/CCOM, etc.)

• Lock/Takeover (terminal takeover)

• Update Configuration maps (Map Download/Map Switch)

• Setting a terminal In and Out of configuration

• Shutting down the OPS application

• Administrator - Manages different users and access levels. All access rightsare available to the administrator. Administrators may execute commands onother users, such as adding or removing users, updating users’ access rights,changing users’ passwords, etc.

Page 13: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 C O N T R O L P A N E L

92050005-042-6

License Information

Click this option to open a dialog box containing the Feature Usage List Report.This list indicates the availability, usage and overuse (“overdraft”) of selectedfeatures. Choose the features from the Feature drop-down list.

Site Events

This option displays a list of events at the selected site, according to the Time andSource of event. All logins, logouts and exits are shown in this list. Events aredisplayed according to time frames. Click Previous to view old logs, Next toproceed to the following logs and Today for the log of the day. Click Print to printthe Site Events log and Close to close the dialog box.

Log In/OutThe Log In/Out icons enable you to specify a user name and password to login to theOPS-360. This function ensures that only authorized users gain access to thefunctions that they require.

Config Lib (Configuration Library)The Configuration Library icon provides access to the Configuration Map Libraryfor manipulating and editing maps stored in the OPS-360 Map Library. For moreinformation, see Chapter 4, Configuration Map Library.

Help (Context Sensitive)Enables you to access the OPS-360 online help.

ExitProvides you with the following options:

Page 14: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

C O N T R O L P A N E L O P S - 3 6 0

92050005-04 2-7

Exit Session – Quits the selected OPS session (Presentation Module only), leavingthe OPS application and all other sessions running.

Shut Down OPS – Terminates the OPS application; all OPS management activitiesare stopped.

Site (Site Window Editor)The Site Icon provides access to the Site window. The Site window enables the userto view all the clusters connected to the site, their names and their alarm status.

Three messages may also be displayed on the Site icon.

Violation - This message indicates a violation of the license terms. The operatormay be using features that were not included in the license or using a feature beyondthose allocated to the operator in the license.

LM_ERR - This message indicates that there is no communication with the LicenseManager Daemon.

Connecting - The OPS-360 Presentation Module is trying to connect to theFunctional Module.

From the Site window, the user can open each of the displayed Cluster windows.

The Cluster windows provide the operator with detailed information about the statusof each element in the cluster(s), and enable the operator to perform the followingtasks:

Terminal and Cluster Control

Terminal and Cluster Maintenance

Terminal Configuration Map Operations

For more information, see Chapter 5, Site and Cluster Window.

Page 15: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 C O N T R O L P A N E L

92050005-042-8

Message FieldMessages and user information is displayed on the bottom line of the Control Panel.The messages may be of the following types:

Help message - To view a help message, position the cursor on objects you want toknow about in the application. An explanation of the relevant item is displayed onthe left side of the message field.

Current User message - This message indicates which user is currently logged in.The User Name is displayed on the right side of the message field. If no user iscurrently logged in, the message field will read: “No User logged in.”

Page 16: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

92050005-04 3-1

Software Installation

GeneralThis chapter describes the installation procedures of the software.

This chapter includes the following topics:

Conventions Used in This Document,

Preliminary Installation Steps, page 3-2

Installing the OPS-360 Software on a New Station, or Upgrading from aPrevious Version, page 3-3

Installing the Terminal Software without the OPS, page 3-5

Storing Maps to Diskette/Hard Disk, page 3-5

Loading Maps from Diskette/Hard Disk, page 3-7

Shutting Down the OPS and the SUN Workstation, page 3-8

3

Page 17: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 S O F T W A R E I N S T A L L A T I O N

3-2 92050005-04

Conventions Used in This Document Bold typeface is used for the prompts and printouts of the operating system.

Courier typeface is used for literal operator input, or file path names.

<Courier > typeface in angled brackets is used for variable operator’s input. Thevariable name should be substituted with an appropriate token.

Italics typeface is used for variables and arguments.Note: Each keyboard input is followed by pressing the <Enter > key.

Preliminary Installation StepsBefore installing the OPS software, make sure that a previous version is not running.If you are upgrading from Pulsar 2.x, you must replace the hard disk. Please contactECI Technical Assistance Center (TAC), Tel: +972 3 9266618 for assistance.

Perform the following steps when installing the software from CD-ROM.

1. Login as ROOT

Before starting, if the OPS360 is running, stop the application:

Press the EXIT Icon on the OPS Control Panel.

Alternately, you may terminate the OPS from an xterm window by typing:

opsCheck -terminate

In the xterm window, type su - (the text includes the letters, a blank space and theminus sign)

Password: sys$ops

2. Mount the CD-ROM

Mount the CD-ROM by doing the following:

mkdir /cdrom ( if it does not already exist)

Insert the CD-ROM into the CD-ROM drive and type:

volcheck; df -k (to verify that the /cdrom is recognized).

Page 18: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

S O F T W A R E I N S T A L L A T I O N O P S - 3 6 0

92050005-04 3-3

3. Enter the Scripts Directory

Type the following to enter the correct directory:cd /cdrom/cdrom0/system

Installing the SoftwareThis section describes the installation and how to handle errors during theinstallation. It also describes the necessary steps for upgrading and first timeinstallation.

To install the software on a SUN workstation:

1. To run the installation, type:installOps

Note: Ignore all WARNINGS output messages.

2. The following message appears:

Do you want to save OPS data from the OPS version already installed [y/n]?

Type ‘y’ if an OPS version is already installed. This saves the current OPS data(cluster configuration and maps) before continuing with the new versioninstallation.

Error Handling

If the OPS installation aborts because of disk space shortage, do the following:

1. Type extractOpsData

2. Type removeOpsVersion <opsVerPath>

where <opsVerPath> is the path to the current or previous OPS version.

The OPS path is :

/usr/local/ops_x.x

(where x.x is the version number, for example ops_4.5)

3. Type installOps -importOpsData <importPathName>

where importPathName is the directory displayed at the end of the output ofthe first step (extractOpsData ). A sample directory name is/tmp/opsData_4.5

Note : If installOps aborts for any other reason, follow the abort message instructions.

Page 19: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 S O F T W A R E I N S T A L L A T I O N

3-4 92050005-04

Removing Previous OPS VersionsNote: This step is only necessary if you are upgrading from a previous version of OPS.

It is recommended to delete old OPS versions from the disk when they are no longerneeded.

Note that after removing the ObjectStore server (see Installing the Software,page 3-3), previous OPS versions can no longer run.

• Use the remove command to remove previous versions. For example:

removeOpsVersion /usr/local/ops_4.5

Installing the OPS-360 License FileNote: This procedure is necessary for an upgrade.

This operation should be done using the ‘root’ user.

To install the customer specific license file:

1. Insert the diskette into the diskette drive.

2. Type volcheck

3. Type cp /floppy/floppy0/license.dat /usr/local/ops/etc

4. Type eject floppy (to eject the diskette).

Page 20: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

S O F T W A R E I N S T A L L A T I O N O P S - 3 6 0

92050005-04 3-5

Concluding the Installation

After the OPS software has been successfully installed, you have to remove theCD-ROM and reboot.

1. To remove the CD-ROM, type:

cd

eject cdrom

2. To reboot a SUN workstation, type:

reboot

3. Log back in to automatically start the OPS-360 system:

Login : ops_user

Password : user$ops

Installing the Terminal Software (without the OPS)To install the terminal software only, without installing the OPS software:

• Type the following:

installAuxSw -terminal

cp /cdrom/cdrom0/versions.cf /usr/local/ops/cf

• To verify that the terminal software has been installed correctly, type the following:

checkTerminalSoftware

Storing Maps to Diskette/Hard DiskIn order to create a backup copy of the configuration maps in your library:

Page 21: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 S O F T W A R E I N S T A L L A T I O N

3-6 92050005-04

1. Press the Config Lib. icon on the OPS Control Panel. A Map Library windowopens, displaying all existing maps.

2. Select the map you wish to store/backup. The selected map appears in reversevideo (White text on Black background)

3. Press the Store button. A secondary Store window opens

In the Store window, do the following:4. In the Format section, select the For Edit option.

5. In the Media section, select the storage medium (Diskette or Hard Disk).Note: The Diskette storage option is available only for local use.

If you selected Hard Disk , do the following:

• In the Filter field, type the directory (full path) into which you wish tostore/backup the map. To save the map to the default path, leave the Filterfield as is.

Note: The default directory is initially displayed. Make sure to put an asterisk (*) at the end ofthe path, to include all the files in the map.

• In the File Target field, at the bottom of the window, enter a name for themap you are about to save (up to 8 characters). To save the map under thesame name, accept the pre-entered name in the File Target field.

• Press the Store button.

If you selected Diskette, do the following:

• If there is no diskette in the disk drive, the OPS will prompt you to insert one.Insert a diskette into the disk drive and click OK in the prompting messagebox.

• In the Filter field, type the directory (full path) into which you wish tostore/backup the map. To save the map to the default path, leave the Filterfield as is.

Note: The field displays initially the current directory. Make sure to put an asterisk (*) at theend of the path, so as to include all the files in the map.

Page 22: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

S O F T W A R E I N S T A L L A T I O N O P S - 3 6 0

92050005-04 3-7

• In the File Target field, at the bottom of the window, enter a name for themap you are about to save (up to 8 characters). Make sure that the string/floppy/floppy0/ appears before the assigned name. To save the mapunder the same name, accept the pre-entered name in the File Target field.

• Press the Store button.

To Eject the diskette from the floppy disk drive, do the following:

• On a Solaris - in the xterm window type: eject

• On a SUN type: EjectPcfs

Loading Maps from Diskette/Hard DiskTo load a backup copy of the configuration maps from the hard disk/diskettes toyour library:

1. Press the Config Lib. icon on the OPS Control Panel. A Map Librarywindow opens, displaying all existing maps.

2. Press the Load button. A secondary Load window opens.

In the Load window, do the following:

3. In the Media section, select the storage medium (Diskette or Hard Disk).Note: The Diskette storage option is available only for local use.

4. In the Files section, select the map you wish to load.Note: If you did not save the map to the default directory, go to the appropriate directory.

5. Make sure that the selected map’s name appears in the Target Map field. Themap will appear in the Map Library under the same name it appeared in theTarget Map field.

6. Make sure that the appropriate path appears in the File field.

7. Press the Load button.

8. The loaded map should appear in the Map Library list.

Page 23: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 S O F T W A R E I N S T A L L A T I O N

3-8 92050005-04

Shutting Down the OPS and the SUN WorkstationTo shut down the OPS:

1. Click the EXIT button on the OPS Control Panel (for OPS Versions above 2.6).

2. Click Shut Down OPS.

3. To exit, Click Proceed.

To exit the OPS from an Xterm window:

1. Log in as a super user by typing su - (including the hyphen).

2. Press RETURN (for OPS versions below 2.6, type su ).

3. Type opscheck -terminate .

To shut down the SUN Workstation:

1. Open an xterm window

2. Type su - to log in as a super userNote: all commands should be typed in lower case letters, unless indicated otherwise.

3. At the Password prompt, type sys$ops .

4. At the prompt, type poweroff (in Solaris OS only).

5. If you have a SUN OS, type halt . Wait for the OK echo and switch off theSUN Station manually.

Page 24: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

92050005-04 4-1

Configuration Map Library

IntroductionA Configuration Map is a set of system parameters that determines how a near-endDTX-360 terminal will function facing a far-end terminal.

The Configuration Map Library is a data bank, containing all the named mapsassociated with each DCME site. To access the Configuration Map Library for editing orviewing, click the Config Lib tool icon on the Control Panel.

This will bring you to the Map Library window. This window enables you to store, loadand delete maps.

You can also edit a configuration map by specifying category parameters. Categoriesinclude Map Identification, Mode (DCME and N/W), Trunk Bit Streams and so on.

Note: Other Configuration Map operations, such downloading a configuration map to theBackground, editing background maps and enabling map exchanges between Foreground andBackground are accessible through the Cluster window, see Chapter 5. A Foreground Map is theconfiguration map used by a terminal. A Background Map is an alternate map, kept in the terminal tofacilitate a fast Configuration Map exchange with the Foreground Map.

This chapter describes the following topics:

The Map Library window , page 4-2, describes the window and its functions.

Editing a Configuration Map , page 4-7, describes the Configuration MapCategories window, editing conventions and the map categories provided.

4

Page 25: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 C O N F I G U R A T I O N M A P L I B R A R Y

4-2 92050005-04

The Map Library WindowThe Map Library window, shown below, lists all the configuration maps stored in theConfiguration Map Library .

Note: The Map list contains, as a default, two template maps: one for the ADPCM version and one forthe LD-CELP/ADPCM version. It is recommended to select the appropriate type of map beforestarting to create the required maps for a specific application.

The Map Library window contains the following displays and fields:

Map List - The Map List table has three columns:

• Map Name - The name of the selected map. Point the mouse at this field to activateit (an activated field is surrounded by a black frame). Click once inside the frame toenter edit mode (blinking cursor). In this mode you may type in the name of the mapyou wish to open, view or delete. Each row in this column contains the name of alibrary map. The name of each map may appear in different fonts. The fonts indicatethe Lock status of the map:

Regular - Unlocked

Bold - Locked by currently logged in user.

Italic - Locked by other user.

Page 26: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

C O N F I G U R A T I O N M A P L I B R A R Y O P S - 3 6 0

92050005-04 4-3

• Valid - A mark in this column, in front of a map’s name, denotes a validated map. Ifa row in this column is blank, the map associated with it is not validated.

• Last Update - The date and time appearing in this column are those of the lastupdate of the map.

The window contains the following buttons:

• Open Map Editor - To open a map for editing or viewing, click the map you wishto edit/view in the Map List display. The selected map is accented by a dark reversevideo background and map’s name appears in the Map Name display window. Clickthe Open button. The Configuration Map Categories window opens, displaying thefirst category: Map Identification. For more information, see the Configuration MapCategories - Common buttons, page 4-7.

• Lock Info - Clicking this button opens a dialog box that displays information aboutthe selected locked map. Select a map from the list before clicking this button.

The following information is displayed in the Lock Info dialog box:

Lock State - Locked or Unlocked

Lock Owner

Date and Time issued

Reason of Change - Indicates the reason the terminal was locked or unlocked.

Click OK to close the dialog box.

• Lock/Unlock/Takeover - This button changes depending upon the Lock status ofthe selected map.

If the map is unlocked, the button reads Lock. Clicking the button will lock the map.

If the map has been locked by you, the button reads Unlock. Clicking the button willunlock the map. (Note that a map may only be unlocked by the user who locked it).

If the map has been locked by another user, the button reads Takeover. Clicking thebutton will transfer the lock from the original user to the operator or administratorwho has taken it over. (Note that only administrators and operators may take over amap).

Maps must be locked or taken over in order to perform the following operations:

Delete - To delete a map

Edit/Save - To edit and save a map

Page 27: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 C O N F I G U R A T I O N M A P L I B R A R Y

4-4 92050005-04

Load - To load a map from a CMIF file to the Configuration Map Library. Saving aloaded map under the name of an existing in the Configuration Map Library maycause problems if other users are using this map. It is therefore necessary to lock amap before loading it to the Configuration Map Library.

Once a map is locked, it cannot be changed or saved unless the lock is “taken over”by an administrator or operator. However, locked maps may be saved to another fileby ordinary users.

Note: The lock option is useful if multiple users exist at a terminal.

Note: administrators Only and operators may lock a map.

Delete - To delete an existing library map, click the map you wish to delete in theMap List display. The map’s name appears in the Map Name field.

When you click the Delete button, a confirmation window is displayed with thequestion: Do you really want to delete (map_name) map?

Click Yes to delete the map.

Click No to abort the delete operation.

• Print - To print a configuration map file.

When you click the Print button, a Print dialog box opens.

The Print dialog box contains the following fields and displays:

Map Categories - Select a map category by clicking the box next to the desired mapcategory (see 4-12).

Print Mode - Choose between Compressed or Normal.

Default Printer Type - Choose either Line Printer or Postscript Printer.

Print to Postscript File - Choose this option to print the map to a postscript file.The location of the file is shown below. In the File Name field, enter a name for thepostscript file.

Click Print to print the file.

Click Cancel to cancel the operation.

• Load - To load a configuration map (file) from a magnetic storage media into theOPS-360 database. This may be necessary for transferring maps from one OPS-360system to another.

When you click the Load button, a Load dialog box opens. Use it to select the filefor loading and perform the copying procedure from source to target.

Page 28: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

C O N F I G U R A T I O N M A P L I B R A R Y O P S - 3 6 0

92050005-04 4-5

The Load dialog box contains the following fields and displays:

Format - The format of the file you wish to load.

For Edit - A more elaborate storage format used for configuration map editing andtransfer. Select this option if you want to edit the configuration map prior totransferring.

For Exchange - A less elaborate storage format, used primarily for configurationmaps storage and transfer procedures. Select this option if you want to transfer thefile without editing it in the process.

Filter - Used to search and select the file required for loading. After specifying thepath and the name of the required file (including wild cards for a wide search), clickthe Filter button or the Enter key.

Directories - List of directories to which maps may be loaded.

Files - List of maps in each selected directory.

Source File - Type the exact path and file name into which the selected file will beloaded.

Target Map - Type the name of the map as it will appear in the Configuration MapLibrary.

Load - To load the selected file into the Configuration Map Library.

Filter - To select the file(s) indicated in the Filter field. This button performs thesame function as the Enter key for selecting the files required for storage.

Cancel - To close the Load dialog box without performing a File Store operation andreturn to the Open Map window.

Note: For an explanation of the buttons in this window, see The Configuration Map Categorieswindow, page 4-7.

• Store - To store a configuration map (file) from the database to another location(such as a diskette). This may be necessary for transferring maps from one OPS-360system to another.

When you click the Store button, a Store dialog box opens. Use it to select the storefiles (configuration maps) for storage and perform the copying procedure from thedata base onto other storage media.

The Store dialog box contains the following fields and displays:

Source map - The name of the file you wish to store.

Page 29: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 C O N F I G U R A T I O N M A P L I B R A R Y

4-6 92050005-04

For Edit - A more elaborate storage format used for configuration map editing andtransfer. Select this option if you want to edit the configuration map prior totransferring.

For Exchange - A less elaborate storage format, used primarily for configurationmaps storage and transfer procedures. Select this option if you want to transfer thefile without editing it in the process.

Filter - Used to search and select the file required for storage. After specifying thepath and the name of the required file (including wild cards for a wide search), clickthe Filter button or the Enter key.

Directories - List of directories where maps are stored.

Files - List of maps in each selected directory.

Target File - Use this field to write the exact path and file name into which theselected file will be stored.

Store - To transfer the selected file from the data base into the required storagemedia.

Filter - To select the file(s) indicated in the Filter field. This button performs thesame function as the Enter key for selecting the files required for storage.

Cancel - To close the Store dialog box without performing a File Store operation andreturn to the Open Map window.

Page 30: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

C O N F I G U R A T I O N M A P L I B R A R Y O P S - 3 6 0

92050005-04 4-7

Editing a Configuration MapYou can edit a configuration map by selecting a map and clicking the Open Map Editorbutton in the Map Library window. A window, is displayed with the configuration mapcategories. If you click a category, a screen is displayed in which you can enter therequired parameter details. The first Library Map Category screen to open is MapIdentification.

This section describes the following topics:

The Configuration Map Categories window, see below

How to edit parameters, page 4-10

Configuration Map Categories, page 4-12

The Configuration Map Categories WindowThe Configuration Map Categories window, shown below, enables you to editconfiguration map categories.

The window is divided into the following sections:

Categories - This display, on the left-hand side of the window, contains a list of all theConfiguration Map Categories. To select a category, click on it. The selected categoryscreen is displayed and the selected category name is marked rectangle with a gray

Page 31: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 C O N F I G U R A T I O N M A P L I B R A R Y

4-8 92050005-04

background rectangle. For more information Configuration Map Categories, seepage 4-12.

The Configuration Map Categories are color-coded:

White - Editable field/cell.

Grayed-out - For information only.

Blue - Read-only (in table cells).

Category Window - Each Category screen has a different window.

Note: The Category screens are described in detail in the help windows associated with eachcategory screen.

Display area - Displays the configuration map category screen.

Buttons area - A common area of displays and buttons, identical in all the screens. Thecommon buttons area include the following buttons and displays:

• Validate - To perform validation of the entire Configuration Map .

If the validation process is successful, the Validate button is grayed-out.

If the validation process fails, a popup window opens, containing messages about thecauses of the failure (conflicting or faulty information).

• Save - To save the changes from the working copy to the Configuration Map .

If the operation is successful, the yellow modified display window is closed and theSave button is grayed-out.

If the operation fails, a popup window opens, containing clarifying messages.

• Save As - To save the Configuration Map under a different name, in order to createanother Configuration Map .

• Print - To print the current configuration map category screen.

• Apply Changes - Enables the following functions:

Saves the screen’s parameters to a working copy of the configuration map.

Performs a preliminary validation of parameters, at the screen level, to ensure thatparameters are acceptable.

This button is grayed-out until at least one parameter has been changed in theCategory window.

Page 32: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

C O N F I G U R A T I O N M A P L I B R A R Y O P S - 3 6 0

92050005-04 4-9

• Revert - To return to the latest version of the category’s working copy. This versioncontains only changes for which an Apply Changes procedure was performedsuccessfully.

• Set Default Values - To set the page’s parameters to their default values.

• Exit - To exit the Configuration Map Categories window. The window closes andMap Library window is displayed.

If the operation is successful, the Apply Changes and Revert buttons are grayed-out,a yellow Modified display box opens and the Validate, Save and Save As buttonsare activated.

If the operation fails, an error window opens with messages aimed at helping you toidentify the problem.

Page 33: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 C O N F I G U R A T I O N M A P L I B R A R Y

4-10 92050005-04

How to Edit ParametersYou can edit a category by clicking it in the Categories list on the left. Data relevant tothat category is displayed on the right side of the window.

The section below describes how to edit a table cell or multiple table cells. Many of thecatalog windows contain such tables.

Editing a Table Cell

To edit a table’s cell, perform the following steps:

1. Make sure that the cell is editable, meaning that it is white. If it is gray, you cannot edit it.

2. Click on the cell once. The selected cell turns black; the selected data is displayedin reverse video.

3. Click the Edit button below the table. A secondary window with either a pull-down menu display field or a selection of clickable options and several buttonsopens up.

4. To edit the pull-down menu display, do one of the following:

a) If the window contains a pull-down menu, click the button on the right ofthe display field. A pull-down menu opens, displaying the available options.Click the appropriate option. The pull-down menu closes and the fielddisplays the selected value.

b) If the window contains selectable options, click the required option. Thebutton to the left of the selected option appears pressed.

5. Click the OK button to close the pull-down menu and exit editing mode aftersaving the changes. The selected option appears in the selected cell.

Click Cancel to close the pull-down menu and exit editing mode without anychanges.

Page 34: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

C O N F I G U R A T I O N M A P L I B R A R Y O P S - 3 6 0

92050005-04 4-11

Editing Multiple Table Cells

To edit Multiple TC Cells, perform the following steps:

1. Select the first cell you wish to modify or assign a value to.

2. Set the required value for the first cell (see Editing a Table Cell, on page 4-10)

3. Point the mouse at the edited column; click and keep the button pressed. Drag themouse downward across the cells you wish to assign the value to. Each selectedcell is displayed in reverse video (dark).Note : If the selected range of cells extends beyond the limits of the displayed window, scrollthe window up and/or down, using the scrolling arrows on the side of the display window.Press down and hold the keyboard’s Shift button. Resume the selection (marking) processas explained above.

4. After marking all the cells you wish to edit, click the Fill Down button below thetable. A fill down window opens, containing the rows From and To, the editedcolumns name and a Step field.

The Step fields, in all the Fill Down windows except in the case of theDestination column are used to enter the required step (interval).

Use the Up/Down arrows of the Step field, or the cursor and keyboard, toenter the required Step interval for the selected cells.

5. Click OK to affect the selected changes. The Fill Down window closes and thechanged values are displayed in the selected table cells.

Click the Cancel button on the Fill Down window to stop the editing of theselected cells.

Page 35: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 C O N F I G U R A T I O N M A P L I B R A R Y

4-12 92050005-04

Configuration Map CategoriesA Configuration Map contains the following categories:

Map Identification , page 4-13

Modes (DCME and N/W), page 4-15

Trunk Bit Streams, page 4-20

Bearer Bit Streams, page 4-24

Pools and Destinations, page 4-28

Trunk Channel Mapping , page 4-33

System Clocks, page 4-36

Optional H/W Modules, page 4-38

Signaling Interface, page 4-40

Fax Modulation, page 4-43

Alarm Handling , page 4-46

(BIT) Built In Test , page 4-57

Activity management, page 4-59

DLC , page 4-62

Statistics, page 4-67

Miscellaneous, page 4-68Note : The order in which the Configuration Map Categories are edited is significant, since someparameters in some categories are based on, or linked to other parameters in other categories.Ideally, work order will be top-to-bottom - with Map Identification first and Miscellaneous categorylast.

Page 36: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

C O N F I G U R A T I O N M A P L I B R A R Y O P S - 3 6 0

92050005-04 4-13

Map Identification

The Map Identification screen provides information about the selected ConfigurationMap and allows the user to attach comments to the map’s ID display.

Click Map Identification in the categories list to access the following screen:

The Map Identification category screen contains the following displays and fields:

Create Information

This display, which cannot be edited, includes the following fields:

• Organization - The name of the organization to which the system belongs. It iseditable.

• Site Name - The name of the terminal’s site.

• Creation Date - The map’s date of creation.

• Creation Time - The map’s time of creation.

Page 37: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 C O N F I G U R A T I O N M A P L I B R A R Y

4-14 92050005-04

Update Information

This display, which cannot be edited, includes the following fields:

• Number of Updates - The number of updates performed on the selectedConfiguration Map.

• Last Updated By - The name of the user who performed the last update.

• Update Date - The date of the last update.

• Update Time - The time of the last update.

Comment

This field contains comments typed by user(s).

After you have completed configuring a Category Screen, click Apply Changes, toupdate changes to the Configuration Map .

Note: For an explanation of the buttons in this window, see The Configuration Map Categorieswindow, page 4-7.

Page 38: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

C O N F I G U R A T I O N M A P L I B R A R Y O P S - 3 6 0

92050005-04 4-15

Modes (DCME and N/W)

The Modes (DCME and N/W) screen allows the user to determine the system’soperating modes.

Click Modes (DCME and N/W) in the categories list to access the following screen:

The category screen contains the following displays and fields:

System Mode

A pull-down menu which allows the user to select the appropriate system modes:

• IESS-501 - In this mode, the system complies with ITU’s G.763 and G.766Recommendations.

Page 39: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 C O N F I G U R A T I O N M A P L I B R A R Y

4-16 92050005-04

• Enhanced - In this mode, the system is enhanced with an additional LD-CELP, 16Kbit/s compression ratio. The LD-CELP algorithm complies with ITU G.728recommendation.

Network Operational Mode

A pull-down menu which allows the user to select the system’s appropriate operationalmodes:

Note: A Bearer Channel is a unidirectional, digital, transmission path from the transmit unit ofone DCME to the receive unit of another, associated DCME. The BC is used to carryconcentrated traffic between two DCMEs.

• Point to Point: This is a single destination mode.

• Multi Clique: In this mode, one terminal can be connected with up to two(2) distantADPCM terminals (4 LD-CELP terminals), sharing the same bearers, but usingseparate bearer channels for each destination (two cliques for ADPCM, 4 for LD-CELP).

• Multi Destination: In this mode, one terminal can be connected with up to four (4)distant terminals, using the same bearer and sharing Bearer Channels.

• Mixed MC & MD: Includes two cliques - one for a single destination an the otherfor up to three destinations.

A Validated configuration map is a map containing only acceptable parameters.

A grayed-out button or field is temporarily disabled or uneditable. When required forcertain functions and under certain conditions, and when a button/field is required toperform certain functions, the grayed-out button or field becomes active. This meansthat it may be clicked or edited.

Click the required operational mode. The button changes state to an In position andthe pull-down menu closes down, displaying the latest selection.

DCME Mode

To select a DCME Mode, click the pull-down menu once to open it up. Click on therequired DCME Mode. The button changes state to an In position and the pull-downmenu closes down, displaying the latest selection.

Note : In the Pulsar Ver. 3.0, only the Point-to-Point operational mode is implemented in theEnhanced system mode.

Page 40: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

C O N F I G U R A T I O N M A P L I B R A R Y O P S - 3 6 0

92050005-04 4-17

If the selected Network Operational mode is either Multi Clique or Mixed MC &MD , the DCME Modes table displays two cliques. The user should set the requiredparameters in both cliques.

IESS-501 System Mode

The parameters (columns) available in the IESS-501 DCME Mode table are:

• Clique - The number of available cliques – 2 cliques for IESS-501

4 cliques for enhanced

• In Config - A clique may be either IN or OUT of configuration.

If the clique is IN configuration, a is displayed in form of its number in the InConfig column.

If the clique is OUT of Configuration, its In Config column is blank (empty).

To change the configuration, see page 4-10.

IESS-501 mode can be either Intelsat Rev. 2 or Intelsat Rev. 3.

Intelsat Rev. 2:

This is a mode that includes speech and voice band data, and does not include faxdemodulation. Rev. 2 allows operation in Multi-Clique operation mode.

Select the cell as described in Editing a Table Cell, on page 4-10.

If you select Intelsat Rev. 2 mode, the following columns are set to non-editable,read-only mode with the following parameters:

16 kb/sec - Disable

DLC mode - Global DLC

Disconn idle call mess - Disable

Fax modulation - Disable

Intelsat Rev. 3

This is a mode that includes speech, voice band data, and fax demodulation. Multi-Destination Operational Mode is also available.

In this mode, all cells in the system mode table are editable. The cells are:

Page 41: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 C O N F I G U R A T I O N M A P L I B R A R Y

4-18 92050005-04

• 16 Kb/sec ADPCM overload - Enable this option to allow the overload channel togo down to two (2) bits per sample under traffic overload conditions.

• DLC (Dynamic Load Control) - Enable this option to select between selective andglobal DLC.

• Global - In this state, the DLC is enabled/disabled for all destinations.

• Selective - In this state, the DLC signal is sent only to the destination that isexperiencing overload conditions.

• Disconnect Idle Call Mess. - Enable this option to enable disconnection of IT(Intermediate Trunk) to BC (Bearer Channel) routing after 1 minute.

• Fax Modulation - Enable this option to enable fax Demodulation/Remodulationcompression process.

• Channel Check Procedure - The channel check procedure is an internal end-to-endtest of the system.

To change the setting of the Channel Check Procedure cell, select the cell asdescribed in Editing a Table Cell, on page 4-10.

Change the setting to either Enable or Disable:

Enable - If this field is enabled.

Disable - If this field is disabled.

Enhanced System Mode

In Enhance System Mode, you may choose to add:• LRE Mode - In Enhanced System Mode, the LRE Mode cell may be set to either

ADPCM or LD-CELP options.

To change the setting of the LRE Mode cell, select the cell as described in Editing aTable Cell, on page 4-10.

In LD-CELP mode, the system receives additional 16 kbit/s compression. In thismode, the terminal may communicate only with another terminal in enhanced mode.

In ADPCM mode, the terminal may communicate with other non-enhancedterminals.

Attention: After you have completed configuring a Category Screen, click Apply Changes, to updatechanges to the Configuration Map. For an explanation of the buttons in this window, see TheConfiguration Map Categories window, page 4-7.

Page 42: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

C O N F I G U R A T I O N M A P L I B R A R Y O P S - 3 6 0

92050005-04 4-19

• Voice Encoding Rate: This option allows you to choose the voice encoding rate forthe selected clique. To change the setting of this cell, select the cell as described inEditing a Table Cell, on page 4-10. Change the setting to either Dynamic or 16Kb/sec.

• Dynamic - Enabling this option allows the voice encoding rate to be changedaccording to the system load. The Variable Bit Rate (VBR) process is enabled. Theencoding rate changes to one of the following: 16, 12.8 or 9.6 Kb/sec.

• 16 Kb/sec - The voice encoding rate is fixed at 16 Kb/sec (ABS=2). VBR process isdisabled.

Page 43: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 C O N F I G U R A T I O N M A P L I B R A R Y

4-20 92050005-04

Trunk Bit Streams

The Trunk Bit Stream category screen, shown below, is used to set up the parametersof the incoming signal from the local exchange to the terminal.

Click Trunk Bit Streams in the categories list to access the following screen:

The Trunk Bit Stream category screen contains the following tables, fields anddisplays:

• CRC-4: A transmission error check option. It provides the data from which the trunkerror performance report is generated.

• Trunk Side Interface: 2.048 Mbit/s (2Mbs), and1.544 Mbit/s (1.5Mbs). Each ofthese options has a configuration table that is displayed upon selection of aninterface.

Note: Before starting work on the Trunk Bit Stream Table , click the appropriate value in theTrunk Side Interface display (1.5 Mbs or 2Mbs ). The system’s default values are: 2Mbs and75Ω. If you selected the 2Mbs option, proceed to select the appropriate impedance (75Ω or120Ω)

Page 44: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

C O N F I G U R A T I O N M A P L I B R A R Y O P S - 3 6 0

92050005-04 4-21

• Impedance: Select the appropriate impedance for the terminal.

Click the button on the right of the impedance field. A pull-down menu opens,displaying the available options. Click the appropriate option. The pull-down menucloses and the field displays the selected value.

Note : Make sure that your selection matches the jumper settings on the terminal’s or (for stand-alone terminal) board(s).

• Trunk Bit Stream Table - The cells of Trunk Bit Stream tables are color-coded:

White - Editable data

Blue - Read-only data

Trunk Bit Stream Table - 2Mbs

The Trunk Bit Stream Table for 2MB, shown on the previous page, is displayed whenyou specify 2MB in the Trunk Side Interface parameter. You can edit cells or multiplecells in the table by following the procedures described on page 4-10.

The 2Mbs Trunk Bit Stream Table contains the following columns:

• Trunk # - This is the trunks’ serial number, from 1 to 12.

• In Config - If the cell is empty, the trunk is Out of Configuration . All the othercells in this row will be empty and blue (read only).

If the cell is marked by a , the trunk is In Configuration. The other cells in therow are white and contain editable data.

To change the configuration, refer to page 4-10.

• CRC-4 - This is a transmission error check option. It provides the data from whichthe trunk error performance report is generated. The configuration option available inthis cell is Disable. When the Trunk is In Config, the CRC-4 is editable. Otherwise,it is empty and blue (Read-only).

• Modified Alignment - The configuration option available in this cell is Disable.

• E-bit Indicator - The E (Error) bit indicator enables the near end to report theportion of errors that was detected at the far end. The configuration options availablein this cell are Enable andis Disable.

Page 45: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 C O N F I G U R A T I O N M A P L I B R A R Y

4-22 92050005-04

To edit a cell for the CRC-4, Modified Alignment and E-bit Indicator parameters,perform the following steps:

1. Select the cell, as described in Editing a Table Cell, page 4-10.

2. Click the Disable or Enable buttons in the dialog box.

3. Click the OK button. If the operation is successful, the selected option appears inthe selected cell.

If this cell is set to Disable, the cells to its right (Modified Alignment and E-BitIndicator) are blue (Read-only).

Trunk Bit Stream Table - 1.5Mbs

The Trunk Bit Stream Table for 1.5MB, shown below, is displayed when you specify1.5MB in the Trunk Side Interface parameter. You can edit cells or multiple cells in thetable by following the procedures described on page 4-10.

The 1.5Mbs Trunk Bit Stream table contains the following columns:

• Trunk # - The trunks’ serial number, from 1 to 12.

Page 46: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

C O N F I G U R A T I O N M A P L I B R A R Y O P S - 3 6 0

92050005-04 4-23

• In Config - If the cell is empty, the trunk is Out of Configuration . All the othercells in this row will be empty and blue (read only).

If the cell is marked by a , the trunk is In Configuration . The other cells in therow are white and contain editable data.

To change the configuration, refer to page 4-10.

• Line Equalizer -The selected value for the telecommunication equipment-terminaltrunk cable length (in meters). This cell is editable only when the trunk is InConfiguration .

• Frame Format - In this column, the user can set the Frame Format to American(SF) or European (ESF) standards.

Select the cell as described in Editing a Table Cell, on page 4-10.

• Line Code - In this column, the user can set the Line Code to B8ZS or AMIoptions.

Attention: After you have completed configuring a Category Screen, click Apply Changes, to updatechanges to the Configuration Map.

Note: For an explanation of the buttons in this window, see The Configuration Map Categorieswindow, page 4-7.

Page 47: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 C O N F I G U R A T I O N M A P L I B R A R Y

4-24 92050005-04

Bearer Bit Streams

The Bearer Bit Stream category screen is used to set up the parameters of the outgoingsignal from the terminal. You can edit cells or multiple cells by following the proceduresdescribed on page 4-10.

Click on Bearer Bit Steams in the categories list to access the following screen:

It contains the following tables, fields and displays:

• Bearer Side Interface: The available output bearer capacity are 1.5Mbs, or 2Mbs.Each of these options has a configuration table that is displayed upon selection of aninterface.

Note : Before starting work on the Bearer Bit Stream table, click the appropriate value in theBearer Side Interface display (1.5 Mbs or 2Mbs).

If you selected the 2Mbs option, proceed to select the appropriate impedance (75Ω or120Ω).

Page 48: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

C O N F I G U R A T I O N M A P L I B R A R Y O P S - 3 6 0

92050005-04 4-25

• Impedance: Select the appropriate impedance for the terminal. Click the button onthe right of the impedance field. A pull-down menu opens, displaying the availableoptions. Click the appropriate option. The pull-down menu closes and the fielddisplays the selected value.

Note : Make sure that the selection matches the jumper settings on the terminal’s board.

• Bearer Bit Stream Table: The cells of Trunk Bit Stream tables are color-coded:

White - Editable data

Blue - Read-only data

Bearer Bit Stream Table - 2Mbs

The Bearer Bit Stream Table for 2Mbs, shown on the previous page, is displayed whenyou select the 2Mb Bearer Side Interface parameter. You can edit cells or multiple cellsin the table by following the procedures described on page 4-10.The 2Mbs Bearer Bit Stream table contains the following columns:

• Bearer # - The bearer’s number, from 1 to 4.

• In Config - If the cell is empty, the bearer is Out of Configuration . All the othercells in this row will be empty and blue (read only).

If the cell is marked by a , the bearer is In Configuration . The other cells in therow are white and editable.To change the configuration, refer to page 4-10.

• Generate T.S. 16 Multiframe - The configuration option available in this cell is Disable.

• CRC-4 - A transmission error check option. It provides the data from which thebearer error performance report is generated. When the bearer is In Config, the othercells in the table are editable. Otherwise, it is empty and blue (Read-only).

• Modified Alignment - The configuration option available in this cell is Disable.

• E-bit Indicator - The E (Error) bit indicator enables the near end to report theportion of errors that was detected at the far-end. This cell is Editable only when thetrunk is In Config and the CRC-4 cell is set to Enable.

• Pools In Bearer - Use this cell to set the number of cliques allocated on the bearer(up to 4).Note : This option is not yet implemented.

Note: For an explanation of the buttons in this window, see The Configuration Map Categorieswindow, page 4-7.

Page 49: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 C O N F I G U R A T I O N M A P L I B R A R Y

4-26 92050005-04

Bearer Bit Stream Table 1.5Mbs

The Bearer Bit Stream Table for 1.5Mbs, shown below is displayed when you select the1.5Mb Bearer Side Interface parameter. You can edit a table by following theprocedures described on page 4-10.

The 1.5Mbs Bearer Bit Stream table contains the following columns:

• Bearer # - The bearer’s number, from 1 to 4.

• In Config - If the cell is empty, the bearer is Out of Configuration . All the othercells in this row will be empty and blue (read only).

If the cell is marked by a , the bearer is In Configuration . The other cells in therow are white and contain editable data.

To change the configuration, see page 4-10.

Page 50: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

C O N F I G U R A T I O N M A P L I B R A R Y O P S - 3 6 0

92050005-04 4-27

• Line Equalizer -The selected value for the telecommunication equipment-terminaltrunk cable length (in meters). This cell is editable only when the bearer is InConfiguration .

• Frame Format - In this column, the user can set the Frame Format to American(SF) or European (ESF) standards.

• Line Code - In this column, the user can set the Line Code to B8ZS or AMIoptions.

• Pools In Bearer - Use this cell to set the number of cliques allocated on the bearer(up to 4).

Note : This option is not yet implemented.

Attention: After you have completed configuring a Category screen, click Apply Changes , to updatechanges to the Configuration Map .

Note: For an explanation of the buttons in this window, see The Configuration Map Categorieswindow, page 4-7.

Page 51: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 C O N F I G U R A T I O N M A P L I B R A R Y

4-28 92050005-04

Pools and Destinations

The Pools and Destinations category screen allows the operator to determine the exactsize and configurations of the pool(s) allocated for each destination. You can edit cells ormultiple cells in the table by following the procedures described on page 4-10.

Click Pools and Destinations in the categories list to access the following screen:

It contains the following tables, fields and displays:

• Network Operational Mode: The operational mode assigned to the system in theModes (DCME and N/W) category screen of the configuration map editor.

• Below the Network Operational Mode appears a graphic representation of thesystem’s Transmit and Receive channels.

The transmit-side (Tx) and each destination (Rx) are represented by a channel ruler.The Upper half of each ruler provides a indication of channels, Time Slots (31 for 2Mbit/s and 24 for 1.5 Mbit/s). The lower half of the ruler is divided into BearerChannel segments according to the following division:

Page 52: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

C O N F I G U R A T I O N M A P L I B R A R Y O P S - 3 6 0

92050005-04 4-29

For 2 Mbit/s traffic - 62 BCs for ADPCM and 126 BC for LD-CELP.

For 1.5 Mbit/s traffic - 68 BCs for ADPCM and 96 for the LD-CELP.

Note : including a Control Channel (CC) at the extreme left-hand side of the ruler.

The exact size of each pool is indicated by a movable slide rule above each ruler. Theleft-hand marker of each slid rule, denotes the lower limit of the pool; the right-hand marker of each slide rule denotes the upper limit of the pool. To change the sizeof a pool, click on the pool marker you want to move. The marker turns white. Movethe mouse along the ruler in the desired direction and click again to stop.

To locate a specific bearer channel, point the cursor at it. A floating display widowappears below the cursor’s arrow, showing the number of the channel pointed at.

To view/edit a channel or several channels in a certain pool, point at the channel andclick once. A Pool table opens, containing editable channel-related information.

Note : A Pool table will not be displayed if the cursor points to a channel that is not part of a pool,while attempting to activate a table.

Channel Configuration

This section contains the Set BC Configuration button and a Destination table.

• Set BC Configuration - Click the Set BC Configuration button to view/edit thePool Table. See page 4-31.

The default Pool table is Tx (Low).

You can also view/edit the Pool tables by clicking once the BC part (lower half) ofany Channel Ruler, to display the Pool table for that ruler.

• Color Coded Indicators - These indicators for Bearer Channels appear to the rightof the Set BC Configuration button.

Status changes are performed in the Pool table and the resulting status appears in theappropriate location and color on the Channel Ruler display.

Page 53: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 C O N F I G U R A T I O N M A P L I B R A R Y

4-30 92050005-04

Destination Table

The Destination table contains the following columns:

• Dest # - The number assigned to destination (1-4).

• Rx Bearer - The number of the Receive Bearer (1-4)

• Destination Name - A user-determined name (that is, usually, the full name of thedestination).

A secondary window with an editable Destination Name display field opens. To editthis, point the cursor at the field. An editing cursor appears in the display and itbecomes active. Use the keyboard to edit the name.

Click OK or press <ENTER> to set the new name. The secondary window closesand the new name appears in reverse video in the edited Channel Configurationtable.

• Abbreviated Name: A user-determined abbreviation of the destination name.

To edit an Abbreviation Name cell, follow the steps described in Editing a TableCell, on page 4-10.

A secondary window with an editable Abbreviated Name display field opens. Toedit this field, point the cursor at the field. An editing cursor appears in the displayand it becomes active. Use the keyboard to edit the name.

Click OK or Press CR to set the new name. The secondary window closes and thenew name appears in reverse video in the edited Channel Configuration table.

• Tx Pool: The Tx Pool for which a specific destination is associated with.

To edit a Tx Pool cell, follow the steps described in Editing a Table Cell, on page4-10.

• FE Dest: The far-end destination(s) connected to the near-end terminal.

Attention: After you have completed configuring a Category screen, click Apply Changes , to applychanges to the Configuration Map .

Note: For an explanation of the buttons in this window, see The Configuration Map Categorieswindow, page 4-7.

Page 54: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

C O N F I G U R A T I O N M A P L I B R A R Y O P S - 3 6 0

92050005-04 4-31

Pool Table Window

The Pool Table window is displayed by pressing the Set BC Configuration button inthe Channel Configuration section. This window, shown below, displays all BearerChannel assignments. You can edit cells or multiple cells in the table by following theprocedures described on page 4-10.

The Pool Table window contains the following fields and table:

• Pool: Click this button to open a pull-down menu containing the system’s availablepools. To view/edit a certain pool, click on the pool menu. The pull-down menuopens, displaying a list of available pools. Select the pool you wish to view and clickon it. The pull-down menu closes and the selected pool is displayed on the PoolTable window.

• Pool Boundaries: This is an editable display field at the top of the Pool TableWindow - a numeric indication of the displayed pool’s size.

Page 55: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 C O N F I G U R A T I O N M A P L I B R A R Y

4-32 92050005-04

To edit the pool size using a display window, point at the display window and clickonce. An editing cursor appears in the window. Use the keyboard to edit the poolsize.

Click CR to set the new values. The slide-rule changes to reflect set values.

Pool Table

The Pool table contains the following columns:

• BC # -An uneditable listing of Bearer Channels.

• Assignment - This column displays assigned BCs. Use the Configuration cell to editor configure a cell..

Configuration

This is a list indicating which of the Bearer Channels are in or out of configuration forthe Tx and Rx pools, as well as the types of unmapped preassigned BCs in Rx pools.

To close the Pool Table window, click the Done button at the bottom of the display.

Note: For an explanation of the buttons in this window, see The Configuration Map Categorieswindow, page 4-7.

Page 56: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

C O N F I G U R A T I O N M A P L I B R A R Y O P S - 3 6 0

92050005-04 4-33

Trunk Channel Mapping

The Trunk Channel Mapping category screen allows the operator to map, whenneeded, each individual time slot to the Intermediate Trunk (IT) . You can edit cells ormultiple cells in the table by following the procedures described on page 4-10.

Click Trunk Channel Mapping in the Categories list to access the following screen:

The columns of the Trunk Channel Mapping table are:

• BS, TS (Bit Stream Time Slot) - This is an uneditable list of all available BitStreams and their Time Slots.

Note: TS16 is not listed in this table.

• TC (Trunk Channel) - This is a table of all available Trunk Channels to be mappedinto ITs (Intermediate Channels).

• In Config - If the cell is empty, the Trunk Channel is Out of Configuration . Allthe other cells in this row will be empty and blue (read only).

Page 57: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 C O N F I G U R A T I O N M A P L I B R A R Y

4-34 92050005-04

If the cell is marked by a , the Trunk Channel is In Configuration . The othercells in the row are white and contain editable data.

To change the configuration, refer to page 4-10.

• IT (Intermediate Trunk) - This is a channel mapping method that associates eachTrunk Channel used within the DCME for facilitating Trunk Channelconnectivity to the proper destination.

To edit IT cells, perform the following steps:

1. Select the cell as described in Editing a Table Cell, on page 4-10. A secondarywindow, with an editable IT field, opens.

2. To edit the IT field, point the cursor at it. An editing cursor appears in the field atit becomes active.

3. Use the keyboard to erase (backspace) and retype the IT number that is pairedwith the corresponding TC.

4. Click OK or press CR to set the new value. The secondary window closes and anew name appears in reverse video in the edited IT table.Important: To edit more than one cell at a time in sequence, refer to Editing Multiple Cells.

• Remote IT - The remote DCME IT designation that corresponds to the local ITdesignation. It is edited exactly like the IT cells.

• Destination - This is the destination number as defined by the Near End user.

• Assignment - This cell is used to assign one of the following options to the TimeSlot: Out of Configuration, Dynamic, ADPCM, Preassigned 64Kb/s, Preassigned40Kb/s, Preassigned 32Kb/s, Preassigned 24Kb/s, Preassigned 16Kb/s.

• LD-CELP - Preassigned 64Kb/s, Preassigned 40Kb/s, Preassigned 16Kb/s,Preassigned 12.8Kb/s, Preassigned 9.6Kb/s. The default assignment is Dynamic.

• Tx BC (Transmit Bearer Channel) - The Tx BC denotes the size of the Transmitbearer. This cell is editable only when the assignment is set to other than Dynamic.Select a value:

For IESS-501: between 1-61 for E-1 or between 1-47 for T1.

For Enhanced Mode: between 1-122 for E-1 or between 1-94 for T1.

Page 58: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

C O N F I G U R A T I O N M A P L I B R A R Y O P S - 3 6 0

92050005-04 4-35

• Rx BC (Receive Bearer Channel) - The Rx BC denotes the size of the Receivebearer. This cell is editable only when the assignment is set to other than Dynamic.Select a value:

For IESS-501: between 1-61 for E-1 or between 1-47 for T1.

For Enhanced Mode: between 1-122 for E-1 or between 1-94 for T1.

Attention : After you have completed configuring a Category Screen, click Apply Changes , to applychanges to the Configuration Map. For an explanation of the buttons in this window, see TheConfiguration Map Categories window, page 4-7.

Page 59: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 C O N F I G U R A T I O N M A P L I B R A R Y

4-36 92050005-04

System Clocks

The System Clock Configuration Map Category allows the operator to select thevarious system clocks and their reserve, stand-by clocks.

Click System Clocks in the Category list to access the following screen:

The available clocks are:

• Tx (Transmit) Main and Tx Reserve

• TrO (Trunk Output) Main and TrO Reserve

• Rx (Receive) and Rx Reserve

The source of each of the Transmit clocks can be Trunks (1-12), Bearers (1-4), internaland external clocks.

The source of the Receive and Receive Reserve clocks can be one of four (4) bearers,internal or external clocks.

Page 60: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

C O N F I G U R A T I O N M A P L I B R A R Y O P S - 3 6 0

92050005-04 4-37

To set a clock, click the button to the right of the required clock. A pull-down menuopens. Click the required clock on the pull-down menu. The menu closes and theselected clock source is displayed to the right of the button.

Attention: After you have completed configuring a Category Screen, click Apply Changes , to updatechanges to the Configuration Map.

Note: For an explanation of the buttons in this window, see The Configuration Map Categorieswindow, page 4-7.

Page 61: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 C O N F I G U R A T I O N M A P L I B R A R Y

4-38 92050005-04

Optional H/W Modules

This configuration map category enables the user to Add or Remove, Enable or Disableoptional hardware modules.

Click H/W Modules in the Categories list to display the following screen.

The available modules are:

• Signalling Card: The system Signalling card supports out of band signaling andQ.50.

Click the button. A pull-down menu opens.

Click In Configuration or Out of Configuration .

The pull-down menu closes and the selection appears in the display.

Page 62: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

C O N F I G U R A T I O N M A P L I B R A R Y O P S - 3 6 0

92050005-04 4-39

• Number of Fax Demodulation (transmission) Cards: A Fax Demodulation cardsupports 90 calls up to 9.6 Kbit/s, or 45 calls at 14.4 Kbit/s. The system comprises1 card.

• Redundancy Switching: Two optional cards provide redundancy for the system’scards.

• First Redundancy Card: The first redundancy card (R- ) can provide exclusiveredundancy or redundancy for both bearer or trunk.

To select the redundancy option for this card, click the button. A pull-down menuopens.

Click the required redundancy level. The pull-down menu closes and the selectedlevel appears in the table cell.

• Second Redundancy Card: The Second Redundancy Card can only be selected toprovide Bearer redundancy. Otherwise, the card is Out of Configuration.

To select the redundancy option for this card, click the button. A pull-down menuopens.

Click the required redundancy level. The pull-down menu closes and the selectedlevel appears in the table cell.

• Power Supply Redundancy: The power supply shelf contains six Power SupplyUnits.

Click the button to the left of this option to enable Power Supply Redundancy, inthe event of a power supply unit failure.

Note : This option is available for configurations of up to 3 terminals for the old power supply.

For the new power supply, this option is available for all DTX’s.

Click Apply Changes, to update changes to category screen.

Note: For an explanation of the buttons in this window, see The Configuration Map Categorieswindow, page 4-7.

Page 63: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 C O N F I G U R A T I O N M A P L I B R A R Y

4-40 92050005-04

Signaling Interface

The Signaling Interface category screen is used to set parameters regulating signalingprotocols. You can edit the cells in the table by following the procedures described onpage 4-10.

Click Signaling Interface in the Categories list to display the following screen:

The screen contains the following tables, fields and displays:

• Out of Band Types - Choose from among 4 methods on 16 time slots. Only oneOut of Band (OOB) signaling method may be selected for a terminal.

Click the button on the right for a drop-down list of Out of Band Types. To choosea type, click it.

Page 64: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

C O N F I G U R A T I O N M A P L I B R A R Y O P S - 3 6 0

92050005-04 4-41

• No. of DCME frames between signaling messages - The number of framesbetween signaling messages is set to 6 when OOB signaling is in R2D or R1 mode.

The following methods are available:

R2D - Signaling messages are sent through the control channel (6 PCMframes on LDCELP terminals, 8 on ADPCM terminals).

Multiplexed 1:1 - Every configured trunk TS#16 is transferred to a pre-assigned 64 Kbit/sec bearer time slot.

Multiplexed 2:1 - Every configured trunk TS#16 is transferred to a pre-assigned 32 Kbit/sec bearer time slot.

Multiplexed 4:1 - Every configured trunk TS#16 is transferred to a pre-assigned 16 Kbit/sec channel on the bearer.

• Trunk # - The signaling protocol which is determined for each trunk independently.

• Robbed Bit Signaling - A signaling method in which bits are “stolen” from traffic inorder to transfer data. This option is available only in T1 mode.

• Idle Code abcd - A signaling code for non-signaling periods. The exact code isdetermined according to the switch’s requirements.

• Type - Use this cell to define T.S16 usage: Q50 - DLC and Clear Channel SeizureRelease.

Note : If Q.50 type is selected, the Q.50 and Simplified Q.50 DLC cells are editable.

Q.50 - Select the protocol type If Q.50 is selected. The available types are:

2A - Ericson AXE-10

2B - Alcatel System 12, Siemens EWSD

Simplified Q.50 - DLC onlyNote : If Simplified Q.50 option is selected, the Simplified Q.50 DLC cell is editable.

Simplified Q.50 DLC - The following options are available: DLC per Time slot orDLC per Bit Stream - check if connected to DLC destination selective.

DLC off (per T.S) - If DLC per T.S is selected, coordinate with switchadministrators on the exact Switch DLC code recognition.

DLC on - see above.Note : If the DLC per T.S. option is selected, the DLC off/on (per TS) is editable.

Page 65: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 C O N F I G U R A T I O N M A P L I B R A R Y

4-42 92050005-04

CCS (on TS16) - The Common Channel Signaling (CCS) is used to transfer T.S.16on a bearer to the far-end. To allocate the required channels for this purpose, selectCCS in the Type column. Select the cell as described in Editing a Table Cell, on page4-10.

When the Type column for a specific trunk # displays CCS, the correspondingCCS TX BC, CCS RX BC and CCS Dest# columns are white (editable).

To allocate TX , BX or Dest# channels for CCS, click once on the required celland click the Edit button.

In the secondary window that opens, type the required Bearer Channel and clickOK or Cancel.

Note : Before allocating CCS channels, make sure the channels are free and available. AllTX and RX bearer channels appear in the BC Configuration table, accessed through thePools and Destination Category screen, Channel Configuration section, Set BCConfiguration button.

CCS bearer channel require two nibbles and must start on an even slot.

Attention: After you have completed configuring a Category screen, click Apply Changes , to updatechanges to the Configuration Map.

Note: For an explanation of the buttons in this window, see The Configuration Map Categorieswindow, page 4-7.

Page 66: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

C O N F I G U R A T I O N M A P L I B R A R Y O P S - 3 6 0

92050005-04 4-43

Fax Modulation

The Fax Modulation table contains Fax modulation information about each of the site’scliques. You can edit the cells in the table by following the procedures described on page4-10.

Click Fax Modulation in the Categories list to display the following screen:

The Fax Remodulation table contains the following cells:

• Clique # - Uneditable clique number.

• Demodulation/Remodulation - This parameter is set in the Modes (DCME andN/W) category screen.

• FEC - Forward Error Correction - per clique.

Page 67: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 C O N F I G U R A T I O N M A P L I B R A R Y

4-44 92050005-04

• Apply FEC - Used to determined the FEC usage mode. Below a pre-set bearerperformance, the FEC will turn on automatically.

Note : This cell is uneditable in this version

• Fax Backward Channel via VBD - Acknowledgments from the called fax machineto the calling machine are transferred by a DCME system through a VBD channel(40 Kb/s).

• Fax Selective Deactivation TCs Table- This table contains all the TC(s) that theoperator chooses to deactivate.

BS, TS and TC - These columns contain all the Bitstreams, Timeslots and theirassociated Trunk Channels in the system, displayed sequentially.

Deactivated TC -A list of trunk channels on which the fax option is always disabled.

• NSS-Code FAX Machines Not to be Demodulated Table - The details of Faxmachines that the DTX-360 can not demodulate. The calls originating from thesemachines are transmitted as Voice Band Data (VBD) traffic.

To add a machine to the table, double-click an empty cell from the ManufacturerCode column. A secondary window opens, containing an editable field. Point themouse at this window. A cursor appears in the editable field and the field issurrounded by a black frame. Type in the FAX code (0-ff).

Note: See FAX Code Table below.

Click OK to confirm the selection. The secondary window closes and the codeappears in the selected table’s cell.

Click Cancel to cancel the selection and return to table. The secondary windowcloses.

To add a row to the table, click a table’s cell (it turns black).

Click the Add button.

To Remove a Fax code or a row from the table, click the cell to be removed (it turnsblack).

Click the Remove button.

Click Apply Changes, to update changes to this category screen.

Page 68: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

C O N F I G U R A T I O N M A P L I B R A R Y O P S - 3 6 0

92050005-04 4-45

FAX Codes Table

Manufacturer Code Manufacture CodeBrother 56 Anritsu 1Iwaski 41 Oki 21Casio 61 Canon 11Sanyo 51 Sharp 31Tamura 71 Toshiba 9NEC 49 Nihon Musen 29Hitachi 69 Fuji Xerox 19Fujitsu 59 Matsushita E. 39Matsushita T. 79 Mitsubishi 5Murata 45 Richo 25Tokyo Electric 75 Burroughs 88

Note: For an explanation of the buttons in this window, see The Configuration Map Categorieswindow, page 4-7.

Page 69: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 C O N F I G U R A T I O N M A P L I B R A R Y

4-46 92050005-04

Alarm Handling

Through the Alarm Handling Category Screen, the operator sets up alarm parameters,activates or deactivates alarms and determines the alarm severity levels for various typesof trunk alarms.

Click Alarm Handling in the Categories list to display the following screen.

The Alarm Handling Category Screen contains the following displays, fields andtables:

• Alarm Extension - In this display, the operator determines the extent of alarmcoverage. Click one of the following two options:

Per TS - Click the button to the left of this option to provide alarm indication perTime Slot.

Per BS - Click the button to the left of this option to provide alarm indication per BitStream.

Page 70: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

C O N F I G U R A T I O N M A P L I B R A R Y O P S - 3 6 0

92050005-04 4-47

• Trunk AIS Inject Upon Critical - This option is used to determine whether toinject an Alarm Indication Signal (AIS) .

• Remote Low BER Indication Via Bit 4, TS0 - Click the button to the left of thisoption to enable the near-end terminal to monitor the BER performance of the link asreceived by the far-end terminal.

• Bearer Backward Alarm - A far-end DCME indicates loss of DCME framealignment (DFA) by activating this alarm indication in the Control Channel DCMEframe no. 54; Represents condition of up to 4 Rx bearers.

Contents: 0 = Normal condition.

1 = Alarm condition.

• Alarm Delay in Seconds - Use this display to determine delay setting for Trunksand Bearers.

The Alarm Delay for a trunk is usually longer then the Alarm Delay for a bearer,because bearer’s performance is critical and affects all the trunks (this option iscurrently inactive).

• Trunk - Click the Up/Down scroll pointers to select the available delay (from 0.0 to3.0 seconds, in 0.1 second intervals).

• Bearer - Click the Up/Down scroll pointers to select the available delay (from 0.0 to3.0 seconds, in 0.1 second intervals).

• T1 Carrier Set/Reset Delay in Seconds - Click the Up/Down scroll pointers to Setthe available delay (from 0.0 to 3.0 seconds, in 0.1 second intervals). Repeat thesame procedure to determine the Reset Delay (0-20 seconds).

The Alarm Classification Table displays a list of alarms in the Alarms column and theseverity levels assigned them in the Classification column.

• Alarms Severity Levels are displayed in color and abbreviations. The availableoptions are:

DMA - Deferred Maintenance Alarm (Yellow) - This alarm requires attention atthe earliest convenient time.

SA - Service Alarm (Blue). This alarm is used to attract the operator’s attention to aproblem.

Page 71: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 C O N F I G U R A T I O N M A P L I B R A R Y

4-48 92050005-04

PMA - Prompt Maintenance Alarm (Red). This alarm requires immediateattention.

MEI - Maintenance Event Indication (Orange) This alarm is not indicated on themonitor, but is registered in the data base and included in alarm reports.

• The Alarm Handling Category Screen provides access to the following alarmgroups:

E1 Alarms

T1 Alarms

DCME CC Alarms

Statistics Alarms

CC Performance Alarms

Click Apply Changes, to update changes to category screen.

Note: For an explanation of the buttons in this window, see The Configuration Map Categorieswindow, page 4-7.

Page 72: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

C O N F I G U R A T I O N M A P L I B R A R Y O P S - 3 6 0

92050005-04 4-49

E1 Alarms

Note : For an explanation of alarms, please refer to following T1 Alarm Table.

Page 73: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 C O N F I G U R A T I O N M A P L I B R A R Y

4-50 92050005-04

The E1 Alarms Table contains the following alarms:

• Failure of I/C on Primary Group - This alarm indicates failure of incomingbearers.

• CRC MFR on Primary Group - This is an Rx Error alarm indication from theswitch, on 2mbit/s bit stream.

• LBER on Primary Group - This is an indication of low BER (10E-6 to 10E-3).

• Trunk BS AIS Failure - This is an indication of a failure resulting in an AIS signal(all bits are 1).

• Bearer AIS Failure - This is an indication of a failure resulting in AIS signal (allbits are 1).

• Trunk BS RAI (TS 0) - This is an indication on TS0 of a Trunk Bit Stream alarm.

• Bearer BS RAI - This is an indication on TS0 of a Bearer alarm.

• Trunk BS MFR Alarm (TS 16) - This is an indication, on TS16, of a multi framealarm.

• Trunk BS Remote MFR Alarm (TS 16) - This is an indication, on TS16, of a multiframe remote alarm.

• Trunk BS HSLIP - Tx - Slips are counted as Overflow or Underflow of a buffer onthe Tx-side of the trunk.

Activation Criteria - More than 30 slips in an interval of 1 hour.

Deactivation Interval - Less than 30 slips in an interval of 1 hour.

• Trunk BS LSLIP - Tx

Activation Criteria LSLIP - More than 5 slips during a fixed 24-hour period, butless than 30 slips per hour.

Deactivation Interval LSLIP - Start of a fixed 24-hour period or when the HSLIPthreshold is reached.Less than 30 slips in an interval of 1 hour.

• Trunk BS HSLIP - Rx - Identical to Trunk BS HSLIP Tx but in the oppositedirection. See above explanation.

• Trunk BS LSLIP - Rx - Identical to Trunk BS LSLIP Tx but in the oppositedirection. See above explanation.

• Bearer BS HSLIP - Rx - Slips are counted as Overflow or Underflow of a buffer onthe Rx-side of the bearer.

Page 74: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

C O N F I G U R A T I O N M A P L I B R A R Y O P S - 3 6 0

92050005-04 4-51

Activation Criteria - More than 30 slips in an interval of 1 hour.

Deactivation Interval - Less than 30 slips in an interval of 1 hour.

• Bearer BS LSLIP - Rx

Activation Criteria LSLIP - More than 5 slips during a fixed 24-hour period, butless than 30 slips per hour.

Deactivation Interval LSLIP - Start of a fixed 24-hour period or when the HSLIPthreshold is reached.Less than 30 slips in an interval of 1 hour.

Page 75: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 C O N F I G U R A T I O N M A P L I B R A R Y

4-52 92050005-04

T1 Alarms (Trunk Alarms)

Click on the Trunk Alarms button in the Alarm Handling screen to display thefollowing screen:

The Trunk Alarms Table (T1) contains the following alarms:

• LOS-CFA on I/C primary group - Loss of incoming signal for 2.5 seconds (±0.5s)

• LOF-CFA on I/C primary group - Loss of frame for 2.5 seconds (±0.5s)

• AIS-CFA on I/C primary group - Alarm indication signal for more 2.5 seconds(±0.5s)

• YELLOW-CFA on I/C primary group - Remote Alarm Indication, LOF by Far-end unit.

• LOF or LOS defect on I/C primary group - Indication of Loss of signal or Loss offrame

• HBER on bearer interface primary group - High Bit Error Rate (>10-3) on bearer

• HBER on trunk interface primary group - High Bit Error Rate (>10-3) on Trunk

• LBER on primary group - Low Bit Error Rate (>10-6, <10-3)

Page 76: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

C O N F I G U R A T I O N M A P L I B R A R Y O P S - 3 6 0

92050005-04 4-53

• Trunk BS HSLIP/LSLIP TX/RX - More than 30 slips in an interval of less than 1hour (HSLIP), or More than 5 slips in less than 24 hours, but less than 30 per hour(LSLIP)

Note : For additional information, please refer to DTX-360 Maintenance Manual, section 3.

Page 77: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 C O N F I G U R A T I O N M A P L I B R A R Y

4-54 92050005-04

DCME CC Alarms

Click on the DCME CC Alarms button in the Alarm Handling screen to display thefollowing screen:

The DCME CC (Control Channel) Alarms Table contains the following alarms:

• CC AIS Failure - This is a state marked by a word of 1s (Alarm Indication Signal)sent in the control channel of the BC.

• CC HBER - An alarm will be activated if the High Bit Error Rate in the ControlChannel is >10E-3.

• CC LBER - An alarm will be activated if the Low Bit Error Rate in the ControlChannel is smaller than 10E-3 and greater than 10E-6.

• DCME Frame Loss - A Bearer Backward Alarm will be activated upon loss of aDCME frame (16 PCM frames - in ADPCM; 20 PCM frames in LD-CELP).

Page 78: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

C O N F I G U R A T I O N M A P L I B R A R Y O P S - 3 6 0

92050005-04 4-55

• Bearer Backward Alarm in DCME CC - Remote alarm indication on the ControlChannel.

To change a DCME CC alarm severity level, select a cell, as described in Editing aTable Cell, on page 4-10.

A secondary window opens containing an Alarm Classification pull down menu.

Click the button. A pull-down menu opens. Click the required alarm level. Thepull-down menu closes and the selected alarm appears in the display window.

Click OK to confirm the selection. The secondary window closes and the selectedoption appears in the selected table’s cell.

Click Cancel to cancel the selection and return to the table. The secondary windowcloses.

Page 79: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 C O N F I G U R A T I O N M A P L I B R A R Y

4-56 92050005-04

CC Performance Alarms

Click on the CC Performance Alarms button in the Alarm Handling screen to displaythe following screen:

The CC Performance Alarms Table contains the following alarms:

• Bearer Average BER per STI - This is a statistical indicator of the BERperformance

• Bearer BER Excesses per STI - This is a statistical indicator of the BERperformance

Page 80: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

C O N F I G U R A T I O N M A P L I B R A R Y O P S - 3 6 0

92050005-04 4-57

Built-in Test

Click Built in Test in the Categories list to display the following screen:

The Built-In-Test (BIT) circuits and software are the main tools used by the cards of theDTX-360 for self-regulation and trouble-shooting.

The BIT enables automatic identification of any failed card in the system.

The BIT outputs are used to trigger actions such as management reports, redundancyswitching, system reset, maintenance, alarms etc.

BIT testing is provided for Transmit (Tx) cards, Receive (Rx) cards, Interface (IF) cardsand Signal Analysis (SA) cards.

Note : For detailed BIT information, consult the Maintenance Manual.

Page 81: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 C O N F I G U R A T I O N M A P L I B R A R Y

4-58 92050005-04

The BITs in all the system’s cards are enabled by default.

Note: Before editing any BIT field, click the Built in Test button on the top left corner of the categoryscreen. When the button is in the IN position, all the BIT status cells are white and editable; except forunavailable cards in certain modes. For example, in Enhanced Mode, the ADPCM card is non-editable.

• AIS Injection Upon Critical Alarm - Enabling this feature causes AIS (AlarmIndication Signal, or “all ones”) injection to all output BS’s, trunks and bearers in theevent of a critical state at the terminal. If Alarm Extension per BS is selected,AIS/2M will be injected.

Click the radio button to enable AIS Injection Upon Critical Alarm .

Note: This option is displayed only when the Built in Test process is enabled.

To change a card’s BIT status, Select a cell to the right of the card’s name, as describedin Editing a Table Cell, on page 4-10.

A secondary window opens, containing the options Enable and Disable.

Click the required option. The button of a selected option is in the IN position.

Click OK to confirm the selection. The secondary window closes and the selected optionappears in the selected table’s cell.

Click Cancel to cancel the selection and return to the table. The secondary windowcloses.

Click Apply Changes, to apply changes to category screen.

Note: For an explanation of the buttons in this window, see The Configuration Map Categorieswindow, page 4-7.

Page 82: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

C O N F I G U R A T I O N M A P L I B R A R Y O P S - 3 6 0

92050005-04 4-59

Activity Management

The Activity Management category screen is used to set and modify speech detectionmodes and levels and noise injection modes and levels. according to CCITT G.763.

Click Activities Management in the Categories list to display the following screen:

The Activity Management category screen contains the following displays, fields andtables:

• Speech Detector Type (for future Implementation) - Click the appropriate buttonto select Adaptive (variable) or Fixed speech detection policy (the option is currentlyinactive).

If the Fixed Speech Detection Type was selected, set the required Speech detector

Threshold [dBm]. Click the button. A pull-down menu opens. Click the requiredSpeech Detection Threshold Level. The pull-down menu closes and the selectedthreshold appears in the Display window.

Page 83: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 C O N F I G U R A T I O N M A P L I B R A R Y

4-60 92050005-04

• Data Activity Threshold [dBm] - For data traffic, activity detection threshold mustbe set.

Click the button. A pull-down menu opens. Click the required Data DetectionThreshold Level. The pull-down menu closes and the selected threshold appears inthe display window.

• Rx Speech Detector Threshold [dBm] (For future implementation) - Thisthreshold is set to determine enabling and disabling of speech detection adaptationand to suppress echo loopback to transmitting side.

Click the button. A pull-down menu opens. Click the required Rx SpeechDetection Threshold Level (currently set to Disable). The pull-down menu closesand the selected threshold appears in the Display window.

• Rx Noise Injection - This facility is provided to prevent periods of complete silenceon the line.

• Matched (Rx Noise Injection) - Click the button to the left of the word match toenable variable noise injection and matching line noise levels.

• Maximum Noise Limitation [dBm] - If the Match option is selected, a MaximumNoise Limitation Level can be set.

Note: The Max Noise Limitation option is active only if the Rx Noise Injection Matched option isselected ( that is currently set to Disable ).

Click the button to the left of the Max Noise Limitation option.

Click the button. A pull-down menu opens. Click the required Max NoiseLimitation level . The pull-down menu closes and the selected limit appears in thedisplay window.

• Trunk # - This is the incoming trunk’s number.

• Noise Level [dBm] - This is the fixed noise level assigned to the trunk.

To change the noise Level for a trunk, select a cell, as described in Editing a TableCell, on page 4-10.

A secondary window opens, containing a Noise Level [dBm] pull-down menu.

Click the button. The pull-down menu opens.

Click the required Noise Level (currently set to 8). The pull-down menu closes andthe selected limit appears in the Display window.

Page 84: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

C O N F I G U R A T I O N M A P L I B R A R Y O P S - 3 6 0

92050005-04 4-61

Click OK to confirm the selection. The window closes and the selected optionappears in the selected table’s cell.

Click Cancel to cancel selection and return to the table. The window closes.

Click Apply Changes, to update changes to category screen.

Note: For an explanation of the buttons in this window, see The Configuration Map Categorieswindow, page 4-7.

Page 85: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 C O N F I G U R A T I O N M A P L I B R A R Y

4-62 92050005-04

DLC

The Dynamic Load Control (DLC) tables in the DLC Configuration Map Categoryallow the operator to determine the system’s overload-handling characteristics. When thetraffic load exceeds set limits, traffic to overloaded trunks is stopped.

Click DLC in the in the Categories list to display the following screen:

The DLC Category window contains the following fields, tables and displays:

DLC Mode

The DLC Mode appearing in this display is determined in the Modes (DCME and N/W)category screen.

• Destination Selective Parameters - The parameter that can be set per destination isthe Allocated Bearer Channels.

• Dst1 - This column contains the number of allocated Bearer Channels.

To change the Allocated Bearer Channels for a destination, Select a cell, asdescribed in Editing a Table Cell, on page 4-10.

Page 86: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

C O N F I G U R A T I O N M A P L I B R A R Y O P S - 3 6 0

92050005-04 4-63

A secondary window opens, with an editable Allocated Bearer Channels displayfield. To edit the Allocated Bearer Channels field, point the cursor at the field. Anediting cursor appears in the display and it becomes active. Use the keyboard to editthe required bearer channels.

Click OK or CR to set the new parameter. The secondary window closes and thenew parameter appears in reverse video in the edited Channel Configuration table.

Click Cancel to exit without applying any changes.

Voice/VBD DLC Thresholds

In order to avoid rapid DLC on-off oscillation, the operator can set High Load and LowLoad limits. The Voice/VBD DLC Thresholds table contains the following cells:

• Average Bits Per Sample (ABS) - The average number of bits used to sample aVBD call. Available only if the Voice Encoding Rate in the “Modes” category is16Kbs.

• Data Bearer Occupancy (DBO) - Proportional occupance (in percents) of databearer.

• High Load - The measured (ABS) < (ABSth) OR the measured (<DBO>) >(DBOth).

• Low Load - The measured (ABS) > (ABSth) and the measured (<DBO>) <(DBOth).

DLC is activated above the High Load and deactivated below the Low Load.

To change the an ABS or a DBO field, Select a cell, as described in Editing a TableCell, on page 4-10.

A secondary window opens, with an editable ABS/DBO display field. To edit theABS/DBO field, point the cursor at the field. An editing cursor appears in the displayand it becomes active.

Note: Allowable upper and lower ABS and DBO limits appear on respective secondary windows.

Use the keyboard to edit ABS/DBO values.

Click OK or CR to set the new parameter. The secondary window closes and thenew parameter appears in reverse video in the edited ABS/DBO.

Click Cancel to exit without applying any changes.

Page 87: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 C O N F I G U R A T I O N M A P L I B R A R Y

4-64 92050005-04

First Stage Averaging Period [msec]

This is the interval between each averaging of the number or bits per sample (ABS).

To change the first stage averaging period, select the cell, as described in Editing aTable Cell, on page 4-10.

Click the button. A pull-down menu opens. Click the required Noise Level. Thepull-down menu closes and the selected limit appears in the Display window. ClickOK to confirm the selection. The confirmation window closes and the selectedoption appears in the selected table’s cell.

Click Cancel to cancel the selection and return to the table. The confirmationwindow closes.

Voice/VBD DLC Deactivation Timer (Ta) [sec]

Setting this timer determines the hangover period of the Voice/VBD DLC.

To change the an Voice/VBD DLC Deactivation Timer (Ta) [sec] field, select acell, as described in Editing a Table Cell, on page 4-10.

A secondary window opens, with an editable display field. To edit the field, point thecursor at the field. An editing cursor appears in the display and it becomes active.

Note: Allowed upper and lower limits appear on secondary window.

Use the keyboard to edit the required Voice/VBD DLC Deactivation Timer (Tb)[sec] values.

Click OK or CR to set the new parameter. The secondary window closes and thenew parameter appears in reverse video in the edited cell.

Click Cancel to exit without applying any changes.

64 Kbit/s DLC

64 Kbit/s Circuit Limit DLC Activation. The value set in this field is the limit of 64Kbit/sClear Channels allocated to the terminal. If this limit is reached, a message is sent to theISC to stop issuing 64Kbit/s Clear Channel requests.

To change the a 64 Kbit/s Circuit Limit DLC Activation field, select a cell, asdescribed in Editing a Table Cell, on page 4-10.

Page 88: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

C O N F I G U R A T I O N M A P L I B R A R Y O P S - 3 6 0

92050005-04 4-65

A secondary window opens, with an editable display field. To edit the field, point thecursor at the field. An editing cursor appears in the display and it becomes active.

Note: Allowed upper and lower limits appear on secondary window.

Use the keyboard to edit 64 Kbit/s Circuit Limit DLC Activation values.

Click OK or CR to set the new parameter. The secondary window closes and thenew parameter appears in reverse video in the edited cell.

Click Cancel to exit without applying any changes.

64 Kbit/s DLC Deactivation Timer (Tb) [sec]

Setting this timer determines the hangover period of the 64Kbit/s DLC.

To change the a 64 Kbit/s DLC Deactivation Timer (Tb) field, select a cell, asdescribed in Editing a Table Cell, on page 4-10.

A secondary window opens, with an editable display field. To edit the field, point thecursor at the field. An editing cursor appears in the display and it becomes active.

Note: Allowable upper and lower limits appear on secondary window.

Use the keyboard to edit 64 Kbit/s DLC Deactivation Timer (Tb) values.

Click OK or CR to set the new parameter. The secondary window closes and thenew parameter appears in reverse video in the edited cell.

Click Cancel to exit without applying any changes.

DLC/TCH Interaction

Enabling this feature causes the system to reject a request for Clear Channel ifVoice/VBD DLC is ON.

To set the DLC/TCH Interaction parameter, select a cell, as described in Editing aTable Cell, on page 4-10.

A secondary window is displayed. Click the Disable or Enable button in the dialogbox.

Click OK to confirm selection. The secondary window closes and the selected optionappears in the selected table’s cell.

Page 89: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 C O N F I G U R A T I O N M A P L I B R A R Y

4-66 92050005-04

Click Cancel to cancel the selection and return to the table. The secondary windowcloses. If the operation is successful, the words Disable or Enable appear in theselected cell.

Click Apply Changes, to apply changes to category screen.

Note: For an explanation of the buttons in this window, see The Configuration Map Categorieswindow, page 4-7.

Page 90: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

C O N F I G U R A T I O N M A P L I B R A R Y O P S - 3 6 0

92050005-04 4-67

Statistics

Before setting the statistics time intervals, make sure that the Statistics Implementationbutton is in the IN (pressed) position.

Click Statistics in the Categories list to display the following screen:

The Statistics window consists of the following fields:

• Statistics Time Interval (STI) [min] - This is the system sampling interval for voiceand Voice Band Data traffic.

• Fax Statistics Time Interval (FSTI) [min] - This is the system sampling interval forFax traffic.

• Error Performance Interval (EPI) [min] - This is the system sampling interval forError Performance Statistics.

Note: For an explanation of the Common Buttons area, see Configuration Map Categories -Common Buttons.

Page 91: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 C O N F I G U R A T I O N M A P L I B R A R Y

4-68 92050005-04

Miscellaneous

The Miscellaneous Category screen is used to set the system’s Network Managementparameters to No Network.

Click the Miscellaneous button to display the following screen:

The Miscellaneous screen consists of the following fields:

• Network Management Method - For future implementation

• First Data Hangover Value (sec) - This is a timer that measures the length of thefirst inactivity period following a period of data transmission. The default is 10seconds. This is intended to prevent disconnection of modem resources, while dataactivity may still start again.

• Second Data Hangover Value - This is a timer that measures the length of a secondconsecutive inactivity period following data transmission. The default is 100 msec.This is intended to still allow resumption of data transmission without resourceallocation delay.

Click Apply Changes, to update changes to Miscellaneous screen.

Note: For an explanation of the Common Buttons area, see Configuration Map Categories -Common Buttons.

Page 92: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

92050005-04 5-1

Site and Cluster WindowThe OPS-360 Site window, below, is used to monitor and control the clusters at asingle site. The Cluster window, page 5-5, is used to monitor and configure eachterminal in a cluster. This chapter describes these two windows in detail.

Site WindowThe Site window provides monitoring and control capabilities of a locationcontaining one or more clusters.

To open the Site window, click once on the Site icon in the Control Panel. Thefollowing window is displayed:

The Site window displays all the clusters currently connected to the OPS-360system.

5

Page 93: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 S I T E A N D C L U S T E R W I N D O W

5-2 92050005-04

Each cluster is represented by a cluster box. The cluster box contains a graphicrepresentation of all the terminals configured in the cluster, including Redundantterminal and Local and Central COMS. Each terminal is assigned a number; theLocal COM in marked by an L; the Central COM is marked by a C.

The background color of each cluster box reflects the highest state of alarm existingin that cluster. In addition, a framed message displays the name of the cluster andanother framed message displays the alarm level (if the cluster is in an alarmsituation). If you click a cluster, a window is displayed with the cluster details. Formore information, see page 5-5.

The Site window also contains the following pull-down menus:

Cluster Menu, shown below

Setup Menu, page 5-3

Cluster MenuThe Cluster menu contains the following options:

Open

Exit

Exit All

Open

The Open option displays a detailed view of a selected cluster.

Exit

Clicking the Exit option closes the Site window.

All other windows that may have been opened during the operator’s work remainopen.

Exit All

Clicking the Exit All option closes all the windows that may have been opened bynavigation from the Site window (the Config Map window will remain open).

Page 94: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

S I T E A N D C L U S T E R W I N D O W O P S - 3 6 0

92050005-04 5-3

Setup MenuThe Setup menu of the Site window contains the following options:

Add Cluster

Remove Cluster

Edit Info

Edit Site Info

Add Cluster

Clicking the Add Cluster option opens a dialog box containing the following:

• Cluster Number - Click on the required number from this pull down list toselect the number to be assigned the new cluster.

• Cluster Name - Place the cursor in the input field and type the name you want togive the new cluster.

Click OK to add an empty cluster box to the Site window. The only availableinformation about an empty cluster box is its name. To add terminals and COM unitsto this empty cluster, select it and click the Open option in the Cluster pull-downmenu (see page 5-2).

Page 95: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 S I T E A N D C L U S T E R W I N D O W

5-4 92050005-04

Remove Cluster

Clicking the Remove Cluster option removes a cluster form the Site window.

• If the cluster is empty (contains no terminals or COM units) a confirmationwindow will open with the question:

“Are you sure you want to remove this Cluster?”

Click Yes to remove the cluster from the Site window.

Click Cancel to close the confirmation window and cancel the remove operation.

• If the cluster is not empty (that is, it contains terminals and/or COM units), awarning window will open with the message:

“Remove all components from the cluster before removing the cluster itself.”

You will not be able to remove this cluster from the site until all components areremoved from this cluster.

Edit Info

Clicking the Edit option opens a dialog box in which you can change the clustername.

To change the cluster’s name, place the cursor in the name field and type the newname you want to give the chapter.

Edit Site Info

Clicking the Edit Site Info option opens a dialog box in which you can change thesite name.

To change the site’s name, place the cursor in the name field and type the name thatyou want to give the site.

Page 96: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

S I T E A N D C L U S T E R W I N D O W O P S - 3 6 0

92050005-04 5-5

Cluster WindowThe Cluster window displays all the information required to determine the exactstatus of each terminal in the cluster. It also enables you to configure each terminal,configure the cluster, operate and control their individual components, and derivesystem reports.

Click a cluster in the Site window to display the following window:

The Cluster window contains the following pull-down menus and tool icons. Eachof these menus is described in detail on the specified pages.

Terminal Menu, page 5-9

Lock Menu, page 5-17

Maintenance Menu, page 5-20

Map Menu, page 5-23

Setup Menu, page 5-29

Tools Menus and Tool Icons, page 5-34

Each square within the Cluster window represents a terminal. The Cluster windowmay also contain one or more rectangles, representing the LCOM, CCOMor SCOM.

Page 97: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 S I T E A N D C L U S T E R W I N D O W

5-6 92050005-04

The background color of each terminal in the Cluster window denotes the alarmlevel of the terminal.

For example the following background colors indicate different alarm levels:

• Red - Critical or Prompt maintenance Alarm

• Yellow - Deferred Maintenance Alarm

• Blue - Service Alarm

• Green - No Alarm

Page 98: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

S I T E A N D C L U S T E R W I N D O W O P S - 3 6 0

92050005-04 5-7

Several fields within each terminal square display the following about the terminal’sname and code.

• Name

• Code Number

• Status (On/Off-line)

• Change-over status (Manual /Automatic)

• Destinations

• Lock indicator

• Alarm

To select a specific terminal in the Cluster window, click on it once. A thick or blackperimeter frame will mark the selected terminal.

A message box, below the Terminal Status displays, provides additionalinformation, such as Link Down and Out of Configuration .

When there is a map mismatch condition, a Map Mismatch (Background - Bg,Foreground - Fg or both) indication is displayed. An orange indicator is a warning that maps stored in the OPS-360 database are not identical tothe respective maps in the terminal’s flash memory. Mismatches may occur for theFg map, Bg map, or both maps. Mismatches are resolved by loading the requiredmaps to the terminal.

Note: When using the Switch Map option in the Map menu to exchange the Fg map with the Bg map,the Map Mismatch indicator will appear again following the operation. This is resolved byDownloading a library map into the terminal’s Bg map.

Note: To clear the Map mismatch message from a redundant terminal, all 18 maps (two for eachterminal) should be downloaded to the terminal. See “Synchronize Maps ”, page 5-25

When a terminal is Out of Configuration , its color changes to gray.

Page 99: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 S I T E A N D C L U S T E R W I N D O W

5-8 92050005-04

Note: A burst of events from a specific terminal may fill the input queue in the FM process to capacity.When this occurs, the OPS-360 option displays this terminal with a grid (net) on top of the alarmstatus color. This is called Reduced Monitoring mode.

When a terminal is in Reduced Monitoring mode:

• Request replies are fully processed.

• State change notifications of the terminal are fully processed.

• Statistic reports are fully processed

• No other event reports are processed. Instead, these events are written to anoutside text file and not logged in the event log.

• In the Event Log window, an event appears when the Reduced Monitoringmode starts and when it ends (indicating that you need a signal for the user tolook at the relevant text file).

Page 100: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

S I T E A N D C L U S T E R W I N D O W O P S - 3 6 0

92050005-04 5-9

Terminal MenuThe Terminal menu contains the following options:

Open Status Report

Open OMCP Monitor

Refresh

Exit

Exit All

Open OMCP Monitor

The OMCP Monitor window allows viewing of various reports generated by aselected terminal.

Clicking the Open Monitor option opens the OMCP Monitor window.

Open Status Report

The Status Report window allows viewing of various reports.

Clicking the Status Report option opens the Status Report window.

Page 101: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 S I T E A N D C L U S T E R W I N D O W

5-10 92050005-04

Status Report

The Status report, shown below, is an online report. This report is constantly updatedin real time. To open this report, select it and click open report in the Open Reportwindow.

The Status report consists of the following fields:

DLC and DCME Link Status , page 5-11

On-line Status, page 5-11

Alarm and Event Summary, page 5-12

Configuration Maps, page 5-12

Software, page 5-13

Page 102: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

S I T E A N D C L U S T E R W I N D O W O P S - 3 6 0

92050005-04 5-11

Five secondary windows may be opened from the Status Report window:

DLC Details - To open this window, press the DLC Details button at the bottom ofthe Status Report window. See page 5-13.

Built-In Test Details - To open this window, press the BIT Details button at the

bottom of the Status Report window. See page 5-14.

Alarms Details - To open this window, press the Alarms Details button at the

bottom of the Status Report window. See page 5-14.

Configuration Details - To open this window, press the Config Details button at

the bottom of the Status Report window. See page 5-15.

Clock Details - To open this window, press the Clock Details button at the bottom

of the Status Report window. See page 5-15.

The Status Report window contains the following sections:

DLC and DCME Link Status

This section contains a graphic representation of the status of the selected terminal.

Inside the terminal’s symbol, there is a graphic representation of the destination towhich the terminal is connected. This representation includes the name of theconnected destination, a DLC ON indication, and a NE/FE status indication.

Incoming trunks are numbered (1-12). All trunks in which alarms have occurred arecolor-coded according to alarm severity configurations. Trunks without alarms aregreen.

Outgoing bitstreams (Tx and Rx bearers) include an indication of the direction of thesignal flow, a clique number, and the incoming bearer number and status.

On-Line Status

This section contains the following fields:

• Change Over Matrix - .Online, Offline, Normal, Manual or Auto.

• OPS Link- Normal, Down or Busy.

• Terminal Status - Existing alarms with text and color indications.

• Current System Clocks - Contains the following fields:

Page 103: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 S I T E A N D C L U S T E R W I N D O W

5-12 92050005-04

Current Tx Clock - Trunk#, Bearer#, Internal.

Current TRO (Trunk Output) Clock - Trunk#, Bearer#, Internal.

Current Rx Clock - Trunk#, Bearer#, Internal.

Alarm and Event Summary

This section contains a table with the following Alarm Categories:

• PCM Bearer - This is an indication of the highest severity level event out of allthe PCM bearer events generated.

• Control Channel - This is an indication of the highest severity level event out ofall the Control Channel events generated.

• PCM Trunk - This is an indication of the highest severity level event out of allthe PCM trunk events generated.

• CSV - This is an indication of a CSV alarm event in one of the terminal trunks.

• Far End Trunk - This is an indication of a remote trunk event in one of thetrunks of the far-end terminal.

• Internal Redundancy - This is an indication that the system is operating on theRedundant QDLI card (QDLI-R).

Note: This alarm category is marked either On or Off.

• DCME Built In Test - This is an indication of an alarm event in one of theterminal cards or the power supply.

The column on the right indicates the severity of the alarm, if an alarm is present.Alarm severity is color-coded according to customized configurations. If no alarmexists, the alarm category is marked “No Alarm.”

Configuration Maps

This section contains a table with the following rows:

Foreground Map

Background Map

The information for each map is:

• Name - Map Name, NoMap if there is no map

Page 104: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

S I T E A N D C L U S T E R W I N D O W O P S - 3 6 0

92050005-04 5-13

• Date - Map Creation (last saving) date

• Rev - This is active map revision number.

Software

This section contains the details of the current (installed) terminal software. Theinformation includes the type of the terminal, the software version, and the date ofinstallation.

At the bottom of the Status Report window, the following buttons appear:

Print/Save - To open the Print/Save Report window.

Exit - To cancel the report display and close the window.

DLC Details

The DLC Details Report window, shown below, is opened by clicking the DLCDetails button on the Status Report window.

The window contains the following fields:

Destination: The destination name.

Note: DLC information appears per destination.

DLC Voice/VBD: On or Off.

DLC 64 Kbit/s: On or Off.

Page 105: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 S I T E A N D C L U S T E R W I N D O W

5-14 92050005-04

Built-In Test Details

The Built-In Test Details window, shown below, is opened by pressing the BITDetails button on the Status Report window.

This window contains a graphic representation of the selected terminal. Each card isdisplayed with its name, function, and status (color coded). If the card is functioningproperly, its color indication is green. If the card is malfunctioning (failed BIT), it iscolor coded according to the severity of the alarm generated by the BIT failuer.

Alarms Details

The Alarms Details window, shown below, is opened by pressing the AlarmsDetails button on the Status Report window. This window is constantly updated inreal time.

The report contains the following sections:

• DCME Status - (Online, Offline)

• Alarm Status - (Critical/Deferred, Prompt, Maintenance)

• OPS Link - (Normal, Down, Busy)

• Control Channel Alarms - This section contains a detailed PCM alarm reportfor each Control Channel. The alarm indication contains the specific fault andthe alarm level associated with the reported fault (such as LOS [PMA] - Loss OfSignal, Prompt Maintenance Alarm).

• PCM Alarms - This section contains a detailed alarm report for each of the bitstreams configured in the terminal. The alarm indication contains the specificfault and the alarm level associated with the reported fault (such as LOS [PMA] -Loss Of Signal, Prompt Maintenance Alarm).

Page 106: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

S I T E A N D C L U S T E R W I N D O W O P S - 3 6 0

92050005-04 5-15

• Far End Trunk Alarms - This section contains alarms that arrive from thetrunks of the far-end terminal.

• Circuit Supervision Trunk Alarms - This section contains a CircuitSupervision alarm report for each of the terminal’s trunks.

The window contains the following buttons:

Print/Save - To open the Print/Save Report window.

Exit - To cancel the report display and close the window.

Configuration Details

The Configuration Details window, shown below, is opened by pressing the ConfigDetails button on the Status Report window.

This section contains the following fields:

System Mode - Enhanced, IESS-501, Rev. 2/Rev.3.

Network Mode - Point-to-Point, Multi-Destination, Multi-Clique, Inter-Operation.

Mode - LDCELP or ADPCM

Fax Compression - On or Off.

FEC - On, Off.

Primary Group Rate - Trunk (2Mbit/s, 1.5Mbit/s) Bearer (2Mbit/s, 1.5Mbit/s).

Clock Details

The Clock Details window, shown below, is opened by pressing the Clock Detailsbutton on the Status Report window.

This window contains a table indicating the following:

Page 107: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 S I T E A N D C L U S T E R W I N D O W

5-16 92050005-04

• Clock - Rx, Tx or TRO. In the event of an alarm in one of the main clocks, acolor-coded indicator is displayed to the left of the clock name.

• Main Clocks -A list of the system’s main clocks (Tx, Rx, TRO) as defined inthe Configuration Map editor. In the event of an alarm in one of the main clocks,an indication is displayed in the right hand column, opposite the clock source.

• Reserve Clocks - A list of the system’s reserve clocks as defined in theConfiguration Map editor. In the event of an alarm on one of the reserve clocks,an indication will be displayed in the right hand column, opposite the clocksource.

• Current Clocks - This is a list of the system’s current clocks.

Note: Changes of clock assignments are made through the System Clocks category in theConfiguration Map Editor.

This window contains the following buttons:

Print/Save - To open the Print/Save Report window.Exit - To cancel the report display and close the window.

Refresh

Clicking the Refresh option sends a refresh request to a selected terminal.

If there is communication between the OPS-360 and the selected terminal, therefresh request will result in examining all the terminal’s parameters and refreshingtheir display on the terminal box in the Cluster window.

If there is no communication between the OPS-360 and the selected terminal, theOPS-360 will try to establish communication with the terminal and display itsparameters on the terminal box in the Cluster window.

Exit

Clicking once the Exit option closes the Cluster window.

All other windows that may have been opened during the operator’s work remainopen.

Exit All

Clicking the Exit All option closes the Cluster window and all windows opened bynavigation from the Cluster window.

Page 108: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

S I T E A N D C L U S T E R W I N D O W O P S - 3 6 0

92050005-04 5-17

Lock MenuThe Lock menu allows the operator to lock, unlock and take over a terminal. TheLock menu offers the following options:

Lock, page 5-17

Lock All , page 5-17

Lock Info , page 5-18

Takeover, page 5-18

Unlock, page 5-19

Unlock All , page 5-19

Lock

Use the Lock option to lock a terminal. Locking a terminal allows only the operatorwho locked it to perform operations on the locked terminal. Before a terminal canbe locked, it must first be selected on the Cluster window.

Select the Lock option. A dialog box opens, displaying the following information:

Lock State - Locked or Unlocked

Unlocked by/Lock Owner

Date and Time issued

Reason of Change - Enter your reason for locking the terminal.

Click Lock to lock the selected terminal.

Click Cancel to cancel the operation.

Note: The Lock option is useful if multiple users exist at a terminal.

Note: Only administrators and operators may lock a terminal.

Lock All

Use the Lock All option to lock all unlocked terminals in the cluster; or to take overall locked terminals in the cluster.

Select the Lock All option. A dialog box opens, containing the following fields:

Scope of Operation - Select All Terminals or Unlocked Terminals Only

Page 109: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 S I T E A N D C L U S T E R W I N D O W

5-18 92050005-04

Reason of Change - Enter the reason for locking all terminals

Click Lock All to lock the terminals.

Click Cancel to cancel the operation.

Note: The Lock option is useful if multiple users exist at a terminal.

Note: Only administrators and operators may lock a terminal.

Lock Info

Clicking this option opens a window that displays information about all locked terminalsin the cluster. Before clicking this option, select a cluster from the Cluster window.

Select the Lock Info option

A window appears, displaying the following information:

Terminal Number

Lock State - Locked or Unlocked

Lock Owner

Date and Time issued

Reason of Change - Indicates the reason the terminal was locked, unlocked or takenover.

Click OK to close the dialog box.

Takeover

If the terminal has been locked by another user, the Takeover option is enabled.Clicking this option will transfer the lock from the original user to the operator oradministrator who has taken it over.

Select the Takeover option. A dialog box opens, displaying the following fields:

Lock State - Locked

Lock Owner

Date and Time issued

Reason of Change - Enter your reason for taking over the terminal.

Click Takeover to take over the selected terminal.

Click Cancel to cancel the operation.

Page 110: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

S I T E A N D C L U S T E R W I N D O W O P S - 3 6 0

92050005-04 5-19

Note: Only administrators and operators may take over a terminal.

Unlock

Clicking this option will unlock a locked terminal. Any user may unlock a terminal.

Select the Unlock option. A dialog box opens, containing the followinginformation:

Lock State - Locked

Lock Owner

Date and Time issued

Reason of Change - Enter your reason for unlocking the terminal.

Click Unlock to unlock the selected terminal.

Click Cancel to cancel the operation.

Unlock All

Click this option to unlock the terminals locked by you; or to unlock all locked terminalsin the cluster (including those locked by others).

Select the Unlock All option. A dialog box opens, containing the following fields:

Scope of Operation - Select All Terminals or Terminals locked by User

Reason of Change - Enter the reason for locking all terminals

Click OK to unlock all terminals.

Click Cancel to cancel the operation.

Page 111: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 S I T E A N D C L U S T E R W I N D O W

5-20 92050005-04

Maintenance MenuBefore using this menu on the Cluster window main menu bar, select a terminal.

The Maintenance menu contains the following options:

In Configuration , page 5-20

Out of Configuration , page 5-20

Change Over, page 5-21

Change Over Release, page 5-22

QLDI Back To Service, page 5-22

Reset, page 5-22

In Configuration

If a selected terminal in a cluster is Out of Configuration, the Terminal Squareappears gray and a message Out of Configuration is displayed.

• Click the In Configuration option to change the terminal’s status to InConfiguration .

• A confirmation window displays the question:

“Are you sure?”

• Click OK to continue.

• Click Cancel to close the confirmation window and cancel the operation.

When the terminal is In Configuration, the Out of Configuration message is notdisplayed and the terminal square alarm color changes from gray to the current alarmstatus of the terminal (Red, Yellow, Blue or Green).

Out of Configuration

If a selected terminal in a cluster is In Configuration:

• Click the Out of Configuration option to change the terminal’s status to Out ofConfiguration .

• A confirmation window is displayed with the question:

Are You Sure You Want Terminal X Out of Configuration?

Page 112: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

S I T E A N D C L U S T E R W I N D O W O P S - 3 6 0

92050005-04 5-21

• Click OK to change the status of the selected terminal to Out of Configuration.

• Click Cancel to close the confirmation window and cancel the operation.

Change Over

Use the Change Over option to transfer DCME operations from a terminal in thecluster to the cluster’s stand-by terminal.

Note: Make sure that the cluster is equipped with a Stand-by terminal and that the Stand-by terminalis not already being used as the redundant terminal for another terminal in the cluster. If the Stand-by

terminal is already engaged, an terminal status message is displayed on its TerminalSquare.

To perform a terminal change over, the cluster must also be equipped with a COMshelf. If a change over was already performed, a message is displayed onits COM Rectangle. (The number displayed is the number of the terminal replacedby the stand-by terminal.)

If the selected terminal is currently operating and the terminal statusmessage is displayed:

• Click the Change Over option once.

• A confirmation window is displayed with the question:

Are You Sure You Want to Change Over Terminal X?

• Click Yes to perform the change over.

• Click Cancel to close the confirmation window and cancel the operation.

On completion of the operation, an terminal status message is displayedon the Terminal Square of the replaced terminal.

A message is displayed on the COM, where the number displays thenumber of the terminal replaced by the stand-by terminal. The number of thereplaced terminal is also displayed. The stand-by terminal displays the terminal status message.

Page 113: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 S I T E A N D C L U S T E R W I N D O W

5-22 92050005-04

Change Over Release

Use the Change Over Release option to release the stand-by terminal and return theoffline terminal back into operation in the cluster.

• Clicking Change Over Release

• A confirmation window is displayed with the question:

Are You Sure You Want to Release Change Over for Terminal (*)?

• Click Yes to perform the release.

• Click Cancel button to close the confirmation window and cancel the operation.

On completion of the operation an terminal status message is displayed onthe selected terminal.

The stand-by terminal displays the terminal status message.

QDLI Back To Service

Use the QDLI Back to Service option to activate the terminal’s internal redundancyprocess and bring back to operation the terminal card.

Note: The QDLI-R card is an optional card.

The QDLI Back to Service brings the terminal back to normal operation.

Reset

Use the Reset option only if you want to perform a reset operation on a selectedterminal.

• Click the Reset option to reset the terminal.

• A confirmation window with the question:

Are You Sure?

• Click Cancel to cancel the reset operation.

• Click OK to display an additional confirmation window with the statement:

Confirm Terminal Reset.

• Click the Reset button to initiate a reset of the selected terminal.

• Click the Cancel button to cancel the operation.

Page 114: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

S I T E A N D C L U S T E R W I N D O W O P S - 3 6 0

92050005-04 5-23

Map MenuBefore using this menu on the Cluster window main menu bar, select a terminal.

The Map menu contains the following options:

View Foreground Map, page 5-23

Edit Background Map, page 5-23

Print Foreground Map , page 5-23

Print Background Map , page 5-24

Download to Background, page 5-24

Enable Map Switch, page 5-25

Synchronize Maps, page 5-25

Upload Foreground, page 5-28

Upload Background, page 5-28

Edit Stby Background Map, page 5-26

Print Stby Background Map

Download to Stby Background, page 5-27

Stby Map Switch, page 5-27

View Foreground Map

Click this option to view (without editing) the selected terminal’s Foreground Map.If there is a Map Mismatch (OPS and Terminal maps are not identical), it is possibleto upload and view a Foreground Map. The map may be saved in order toimplement required modifications (on the saved map with a different name).

Edit Background Map

Clicking this option enables you to edit the background map of the selected terminal.

The first Library Map category – the Map Identification window – opens.

Print Foreground Map

Click this option to open a Print Foreground Map window. From this window, youcan choose those categories of the Foreground map that you want to print.

Page 115: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 S I T E A N D C L U S T E R W I N D O W

5-24 92050005-04

Print Background Map

Click this option to open a Print Background Map window. From this window,you can choose those categories of the Background map that you want to print.

Download to Background

This option displays a window which lists all the maps stored in the ConfigurationMap Library . To select this option in the Cluster window, select Download toBackground window from the Map menu.

The window contains the following displays and fields:

Map List

A list of all the configuration maps stored in the system’s library. The Map List tablehas three columns:

• Map Name - Each row in this column contains the name of a library map.

• Valid - A mark in this column, in front of a map’s name, denotes a validatedmap. If a row in this column is blank, the map associated with it is not validated.

• Last Update - The date and time appearing in this column are those of the lastupdate of the map.

Map Name

The name of the selected map. Point the mouse on this field to activate it (anactivated field is surrounded by a black frame). Click once inside the frame to enteredit mode (blinking cursor). In this mode you may type in the name of the map youwish to open, view, or delete.

The window contains the following buttons:

Download - To download a map into the background, click the map’s name in theMap Name column. The selected map is accented by a dark reversevideo background and map’s name appears in the Map Name displaywindow. Click the Download button.

A confirmation window opens with the text “Confirm Download.” Thefollowing buttons appear:

OK - To perform downloading to background.

Cancel - To return to Download to Background window.

Page 116: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

S I T E A N D C L U S T E R W I N D O W O P S - 3 6 0

92050005-04 5-25

Note: When downloading a library map into a standby terminal (#9), the Download button displaysthe text: Download to Background .

Before using the Download to Background option in the Map pull-down menu,select a terminal.

Click this pull-down menu option to download a background map from the MapLibrary into the selected terminal.

Click the Download to Background button to open a Download to Backgroundwindow.

Enable Map Switch

Use the Enable Map Switch option only if you want to replace a selected terminal’sForeground map by the terminal’s Background map. The selected terminal must beactive (not a standby terminal).

• Click the Enable Map Change option

• A confirmation window appears, displaying the question:

“Are You Sure?”

Click Cancel to close the confirmation window and cancel the operation.

Click OK to continue.

• An additional confirmation window opens with the statement:

Confirm Map Change

Click Map Switch to switch the maps at the selected terminal.

Click Cancel to cancel the operation.

Synchronize Maps

This table is used to compare and synchronize between the Foreground andBackground maps in both the OPS-360 and the selected terminal. The table isdivided in two parts – one representing the Terminal and the other representing theOPS.

Click the Synchronize Maps option to display a Map Synchronization table with thetitle: “Synchronize Window for Terminal #”

The Terminal side contains the following columns:

Page 117: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 S I T E A N D C L U S T E R W I N D O W

5-26 92050005-04

• Map ID - The information in this column identifies the map as either aBackground (Bg) or a Foreground (Fg) map.

• Map Name - The name given to the map by its creator or modifier.

• Last Updated - The date and time of the map’s last update.

• # of Changes - The number of times the map was modified (i.e., the map’sversion).

There are two columns between the Terminal and OPS parts of the table. If a mapon the table is mismatched, arrows will appear in these columns. Click an arrow tosynchronize the maps.

• Download - Click the arrow in the Download column to download abackground map to the terminal. This action synchronizes mismatched maps.

• Upload - Click the arrow in the Upload column to upload a map to the OPS.This action synchronizes mismatched maps.

Note: Foreground maps cannot be downloaded to the terminal. To download a foreground map, firstswitch it to the background and then download it.

Note: Redundant terminals list the maps at other terminals as well. These maps may be downloadedto the terminal (but not uploaded to the OPS).

The OPS side contains the following columns:• Map Name - The name given to the map by its creator or modifier.

• Last Updated -The date and time of the map’s last update.

• # of Changes - The number of times the map was modified (i.e., the map’sversion).

Click Done to close the Map Synchronization Table window.

Upload Foreground

• Click the Upload Foreground option to upload a Foreground map from theterminal into the OPS-360.

• A confirmation window is displayed with the question:

“Are You Sure?”

Click OK to perform the operation.

Click Cancel to cancel the operation.

Page 118: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

S I T E A N D C L U S T E R W I N D O W O P S - 3 6 0

92050005-04 5-27

Upload Background

• Click the Upload Background option to upload a Background map from theterminal into the OPS-360.

• A confirmation window is displayed with the question:

“Are You Sure?”

Click OK to perform the operation.

Click Cancel to cancel the operation.

Edit Stby Background Map

Before using the Edit Stby Background Map option, select the standbyterminal (#9).

Click this option to edit the background map of the standby terminal. The first MapCategory – the Map Identification window – opens.

Print Stby Background Map

Click this option to open a Print Stby Background Map window. From thiswindow, you can choose those categories of the Background map that you want toprint.

Download to Stby Background Map

Clicking this option opens a Download to Background window. This window allowsyou to download a standby terminal background map from the Map Library intothe standby terminal.

Before using the Download to Stby Background option, select the standby terminal(#9).

Stby Map Switch

Before using the Stby Map Switch option, select the standby terminal (#9).

Use this option only if you want to replace the standby terminal’s Foreground mapby the terminal’s Background map.

• Click the Stby Map Switch option

Page 119: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 S I T E A N D C L U S T E R W I N D O W

5-28 92050005-04

• A confirmation window appears, displaying the question:

“Are You Sure?”

Click Cancel to close the confirmation window and cancel the operation.

Click OK to continue.

• An additional confirmation window opens with the statement:

Confirm Map Change

Click Map Change to change to the Background map at the standby terminal.

Click Cancel to cancel the operation.

Page 120: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

S I T E A N D C L U S T E R W I N D O W O P S - 3 6 0

92050005-04 5-29

Setup MenuThe Setup menu provides the operator with tools needed to configure, add, andremove elements from cabinets and clusters.

This menu contains the following options:

Add Terminal, page 5-29

Add Central COM, page 5-30

Add Local COM, page 5-32

Add Single COM, 5-31

Remove, page 5-31

Add Cabinet, page 5-32

Remove Cabinet, page 5-32

Edit Info, page 5-33

Edit Cabinet Info, page 5-33

Add Terminal

Use the Add Terminal window to add a terminal to a cabinet. Before a terminal canbe added to a cabinet, a vacant place must be selected on the Cluster window.

This window contains the following:

• Terminal Number - From the pull-down menu, select an active terminalnumber from the available list. The numbers of terminals that are alreadyinstalled in the cabinet are grayed out.

• Terminal Name - The terminal’s name.

• System Name - The system’s name.

• Protection Mode - From the pull-down menu, select a protection mode for theterminal. The following modes are available: Disabled, Manual and Auto.

• Terminal considered in Cluster Alarm - From the pull-down menu, selectConsidered or Not Considered. Selecting Considered will cause an alarm inthe cluster if the selected terminal is in alarm state.

Page 121: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 S I T E A N D C L U S T E R W I N D O W

5-30 92050005-04

The Local COM section contains the following elements:

• Trunk Group Size

Click one of the following options:

1 Shelf Terminal - For a compact terminal.

2 Shelf Terminal - For a full-size terminal.

• LCOM Number - From the pull-down menu, select the No LCOM option or anumber between 1 and 4.

• Output Number - From the pull-down menu, select a number according to theposition of the terminal in the cabinet: 1 for the first (upper) terminal, 2 for thesecond terminal, 3 for the third, and 4 for the fourth terminal.

Note: Optional numbers 3 and 4 exist only in compact terminals.

This window contains the following buttons:

OK - To add the terminal to the cluster. The Add Terminal window closes.

Cancel - To close the Add Cabinet window without performing any setup operation.

Add Central COMNote: A CCOM can be added to a cabinet only if the cluster does not yet contain a CCOM.

Note: All online report windows should be closed and re-opened after adding an LCOM.

Clicking the Add CCOM option in the Setup menu adds a CCOM to the cluster.

A display box is added to the cabinet, on top of the selected cabinet display.

Note: Before a CCOM can be added to a cluster, a cabinet must be selected in the Cluster window.

Page 122: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

S I T E A N D C L U S T E R W I N D O W O P S - 3 6 0

92050005-04 5-31

Add Local COMNote: Before an LCOM can be added to a cluster, a cabinet must be selected in the Cluster window.

Note: All online report windows should be closed and re-opened after adding an LCOM.

• Click the Add Local COM option to add an LCOM to a cabinet.

• An Add Local window opens, containing the following pull-down menus:

LCOM Number - Select the number of the LCOM (1-4).

Supported Terminals - Select the number of terminals supported by the LCOM: 2or 3.

Click OK to add the LCOM. An LCOM display box is added to the cabinet, on topof the selected cabinet display.

Click Cancel to cancel the operation.

Add Single COMNote: Before an SCOM can be added to a cluster, a cabinet must be selected in the Cluster window.

Note: All online report windows should be closed and re-opened after adding an SCOM.

The SCOM or Single COM is a combination of the Local and Central COMs.

• Click the Add Single COM option to add an SCOM to a cabinet.

• An Add Single window opens, containing the following pull-down menus:

SCOM Number - Always 1.

Supported Terminals - Select the number of terminals supported by the LCOM: 2or 3.

Click OK to add the SCOM. An SCOM display box is added to the cabinet, on topof the selected cabinet display.

Click Cancel to cancel the operation.

Note: An SCOM can be added to a cabinet only if the cluster does not yet contain a SCOM.

Remove

Before a Terminal/LCOM/CCOM/SCOM can be removed from a cluster, theelement must be selected in the Cluster window.

Page 123: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 S I T E A N D C L U S T E R W I N D O W

5-32 92050005-04

• Click the Remove option.

• A confirmation window is displayed with the question:

Are You Sure You Want To Remove This Component?

Click Yes to remove the selected component.

Click Cancel to cancel the remove operation.

Click Help to receive an explanation of this operation.

Add Cabinet

Use the Add Cabinet window to add a cabinet to a cluster. Before a cabinet can beadded to a cluster, a reference terminal must be selected on the Cluster window.

The Add Cabinet window contains the following displays and buttons:

• Cabinet Type - Click one of the following options in this display to determinethe cabinet:

Click Type 1 for a cabinet housing 1-2 terminals (full-size).

Click Type 2 for a cabinet housing 1-4 terminals (compact).

• Position - Click Add to the right to add a cabinet to the right of the selectedposition. Click Add to the left to add a cabinet to the left of the selectedposition.

This window contains the following buttons:

OK - To add a cabinet to the cluster. The Add Cabinet window closes.

Cancel - To cancel the remove operation.

Remove Cabinet

Before a Cabinet can be removed from a cluster, it must be selected in the Clusterwindow. The selected cabinet must be empty (all components have been removedfrom it, using the Remove option in the Setup menu).

• Click the Remove Cabinet option

• A confirmation window appears displaying the question:

Are You Sure You Want To Remove This Cabinet?

Page 124: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

S I T E A N D C L U S T E R W I N D O W O P S - 3 6 0

92050005-04 5-33

Note: If the cabinet is not empty, a warning window alerts you to Remove All ComponentsFrom The Cabinet Before Removing The Cabinet Itself . Click OK to remove cabinetcomponents.

Click Yes to remove the cabinet.

Click Cancel to cancel the remove Cabinet operation.

Click Help for an explanation of this operation.

Edit Info

Clicking the Edit Info option enables you to change terminal or LCOMconfiguration.

Before a terminal, SCOM or LCOM can be edited, it must be selected in the Clusterwindow.

Note: When editing Terminal or LCOM Info, its number and type cannot be changed.

For information on Terminal Info Editing see Add Terminal, on page 5-29.

For information on LCOM Info Editing see Add Local COM, on page 5-32.

For information on SCOM Info Editing see Add Single COM, on page 5-31

Edit Cabinet Info

Clicking the Edit Cabinet Info option enables you to change a cabinetconfiguration. An Edit Cabinet Info window opens.

For more information, see Add Cabinet, on page 5-32.

Note: If you attempt to edit the configuration of a cabinet that is not completely empty, a warningwindow will open, displaying the message: Remove all Components from Cabinet before Editingits Info.

Page 125: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 S I T E A N D C L U S T E R W I N D O W

5-34 92050005-04

Tools Menu and Tool IconsBefore using the Tools menu or the Tool Icons below the main menu bar, select aterminal.

The Tools pull-down menu contains the following options:

Events Log

Reports

ACO (terminal level)

Event Log

The Event Log window provides detailed information of system and user-generatedevents during various periods.

The window contains the following displays and buttons:

Event Table

This table contains the following columns:

• Time - The event’s time in the format HH:MM:SS.

• Source - The exact source of the event (Trunk, Bearer, Terminal).

• Description - Event information such as Loss of Frame (LOF) and a color-coded indication of the severity of the event:

Red - Critical, Prompt

Yellow - Deferred

Blue - Service

Note: Terminal-generated events with “event severity” (for example, any XXX-OFF such as LOS-OFF,AIS-OFF, etc.) are displayed without any color.

Search - Click this button to open the Search sub-window. The following optionsappear in the Search window:

• Previous - Click for a list of events from the previous day

• Today - Click for a list of today’s events

• Next - Click for a list of the next day’s events

Page 126: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

S I T E A N D C L U S T E R W I N D O W O P S - 3 6 0

92050005-04 5-35

Search Sub-window

Use this window to search for specific events. You can search for all of the followingcriteria:

Severity - Choose the desired levels of event severity.

• Critical

• Prompt

• Deferred

• Service

• Cleared

Source - Click for a drop-down list of event sources.

Find Forward - Searches from the beginning of the day onward (00:00). If a particularevent is selected, the search begins from the date and time of that event.

Find Backward - Searches backward from the end of the day (23:59) to the beginning ofthe day. If a particular event is selected, the search begins from date and time of thatevent.

The OPS first searches for events during the current day. If the desired events cannot befound, the OPS automatically searches for these events in the event log from the previousday.

If the events cannot be found, a pop-up message appears; notifying you that there is nomatch for the selected event.

Page 127: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 S I T E A N D C L U S T E R W I N D O W

5-36 92050005-04

Reports

To open the Reports window, click the Reports Icon or Select the Reports option inthe Tools pull-down menu.

The available Reports are:

Traffic Statistics Report, page 5-38

Bearer Control Channel Error Performance Report, page 5-41

Primary Rate Error Performance Report, page 5-42

Fax Statistics Report, page 5-44

Accumulated Busiest Period Report, page 5-46

Accumulated Primary Rate Error Performance Report, page 5-50

Accumulated Fax Statistics Report, page 5-50

Accumulated Control Channel Error Performance, page 5-55

Print/Save Report, page 5-56

Before using the Reports option, select a terminal.

Clicking the Reports option displays the Open Report window.

The window contains the following fields and displays:

Report Names - The titles of the available reports are contained in two displaywindows:

The upper display window contains a list of periodic reports. These reports are issuedonce every pre-determined period or on demand.

Page 128: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

S I T E A N D C L U S T E R W I N D O W O P S - 3 6 0

92050005-04 5-37

The lower display window contains a list of real-time reports. These reports areissued on demand and reflect the status of the reported subject at the time of therequest.

Note: Available (active) reports are displayed in black. Unavailable reports are displayed in gray.

Type (window section) - Used to determine the period for which a report isrequired.

Note: After selecting a report from the Report Names window, available periods for each selectedreport are active (black), and unavailable periods are displayed in gray.

On Demand - Used to receive a report in Real Time - from the time of the mostrecent periodic refreshment of statistics until the time of request, reflecting the statusof the terminal at the time of the request.

Last - Used to receive a report based on the latest accumulation of data.

From - Used to determine the exact period for which a report is required. If youselect this option, proceed to select the Day and the Time from the appropriate pull-down menus below.

The following buttons appear at the bottom of the Open Report window:

Open Report - To open a status for details report, see page 5-10. The report isdisplayed in reverse video.

Print/Save - To open the Print/Save Report window.

Cancel - To cancel the report generation request and close the Open Report window.

Page 129: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 S I T E A N D C L U S T E R W I N D O W

5-38 92050005-04

Traffic Statistics Report

The Traffic Statistics Report contains information about the terminal’s traffic. Toopen this report, select it and click open report in the Open Report window.

The window contains following displays and fields:

From - Contains the report’s date and the time.

Statistic Interval - Informs the user of the pre determined interval that passesbetween updates of the requested report.

No. of Non-Pre-assigned BCs - Shows the number of Bearer Channels which wasdetermined during terminal configuration.

No. of Non-Pre-assigned TCs - Shows the number of Trunk Channels which wasdetermined during terminal configuration.

Bearer Usage

Contains the following parameters:

Total DCME Utilization (%) - The average percentage of BCs (non pre-assigned)which are used for active traffic.

Page 130: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

S I T E A N D C L U S T E R W I N D O W O P S - 3 6 0

92050005-04 5-39

DCME Speech Utilization (%) - The portion of the bearer that is used for speechactivity.

Average no. of Clear Nibbles -The portion of clear nibbles (4 bits) on the bearer forthe report’s time interval.

Average no. of Data BC’s - The portion of Data Bearer Channels on the bearer forthe report’s time interval.

Average no. of Bit Banks - The portion of Bit Banks on the bearer for the report’stime interval.

Average no. of Fax banks - The portion of Fax Banks on the bearer for the report’stime interval.

Voice Statistics

Average Bit per Sample (Voice) - An indicator of speech calls quality.

Worst Bit per Sample (Voice) - An indicator of the system’s traffic load for thereport period.

Average no. of overloaded Channels - An indicator of traffic overload duringreport period.

Voice Activity Ratio (%) - The portion of the bearer that is occupied by speechcalls.

Voice Freeze out Factor (%) - The ratio of competitive clip duration to voice spurtduration.

Voice Freeze out Excess (%) - An indicator of the percentage time voice FOF(Freeze out Fraction) exceeding 0.5%, when averaged over a period of 1 minute.

Worst Voice Freeze out (%) - The highest value of FOF.

Data Statistics

Data Activity ratio (%) - The portion of data traffic out of the bearer’s total non-pre-assigned activity.

Data Freeze out (%) - The ratio of the number of non-pre-assigned TCs classified asdata active but not connected to the total number of non-pre-assigned TCs classifiedas data active.

Worst data Freeze out (%) - The highest value of data freeze out.

Page 131: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 S I T E A N D C L U S T E R W I N D O W

5-40 92050005-04

64 KB/S Statistics

64 Kb/s Connected Ratio (%) - The ratio of successful clear channel switch seizurerequests.

64 Kb/s Failed Seizure Ratio (%) - The ratio of switch clear channel seizurerequest that were turned down.

DLC Statistics for Destination (Name of Destination) - The table displayed belowthis field contains the following rows:

DLC Voice On Ratio (%) - The portion of the DLCs that were initiated by speechcalls.

DLC 64 Kb/s On Ratio (%) - The portion of the DLCs that were initiated by lack ofavailable clear channels.

No. of DLC Operations -The total number of DLC.

The information columns contain the following information:

NE - Near-End

FE - Far-End

Total -Total DLC messages

The last column contains a graphic display of the NE/FE ratio.

A separate table contains the following information:

The number of outgoing and incoming fax calls for the assigned destination.

The window contains the following buttons:

Print/Save - To open the Print/Save Report window.

Exit - To close the Report window and return to the Cluster window.

A display window between the buttons informs the user of the time (in minutes) tothe next report update. When the update time arrives, the user is informed of it bythe message Updating Report. The new report data is then displayed in theappropriate locations.

Page 132: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

S I T E A N D C L U S T E R W I N D O W O P S - 3 6 0

92050005-04 5-41

Bearer Control Channel Error Performance Report

The Bearer Control Channel Error Performance Report, shown below, containsinformation about the bearer control channel. To open this report, select it and clickopen report in the Open Report window.

The Report window contains following display and fields:

From - Contains the report’s date and time.

Statistic Interval - Informs the user of the pre-determined interval that passesbetween updates of the requested report.

The report’s table contains the following information about the assigned destination(s):

Average BER - The ratio of the number of bit errors identified in the control channelto the total number of bits received in the control channel.

BER Excess (%) - The percentage of time during which the average BER exceeds10E-3.

Unavailable Sec (%) - The period of unavailable time beginning when the BER persecond is worst than 10E-3 for a period of 10 consecutive seconds. (See G.821).

Severely Errored Sec (%) - The percentage of available seconds with an error ratebigger than 10E-3. Available is defined according to ITU G.821.

DCME Frame Alarm Sec - The number of seconds during which a DCME framealarm was activated.

The window contains the following buttons:

Print/Save - To open the Print/Save Report window.

Exit - To cancel the report display and close its window.

Page 133: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 S I T E A N D C L U S T E R W I N D O W

5-42 92050005-04

Primary Rate Error Performance Report

The Primary Rate Error Performance Report window, shown below, containsinformation about errors at the terminal. To open this report, select it and click openreport in the Open Report window.

From - Contains the report’s date and time.

Statistic Interval - Informs the user of the pre-determined interval that passesbetween updates of the requested report.

Beneath the Standard field, a button appears. This button allows you to choose eitherNear End or Far End. The report will be displayed accordingly.

The Report window displays the following for each trunk and bearer:

ESR - Errored Second Ratio. The ratio of ES to total seconds in available timeduring a fixed measurement interval.

SESR - Severely Errored Second Ratio. The ratio of SES to total seconds inavailable time during a fixed measurement interval. A one-second period containingat least 30% errored blocks.

Page 134: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

S I T E A N D C L U S T E R W I N D O W O P S - 3 6 0

92050005-04 5-43

BBER - Background Block Error Ratio. The ratio of Background Block Errors tototal blocks in available time during a fixed measurement interval. (The count of totalblocks excludes all blocks during SESs.)

UAS - Unavailable Seconds.

SLIP Tx - Seconds with slip (mismatched times at different clocks) at the Txinterface

SLIP Rx - Seconds with slip (mismatched times at different clocks) at the Rxinterface

Note: Slip Tx and Rx measurements appear only in Near-End reports.

The window contains the following buttons:

Print/Save - To open the Print/Save Report window.

Exit - To cancel the report display and close its window.

Page 135: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 S I T E A N D C L U S T E R W I N D O W

5-44 92050005-04

Fax Statistics Report

The Fax Statistics Report window, shown below, contains information about theterminal’s fax traffic activity. To open this report, select it and click open report inthe Open Report window.

The Fax Statistics Report contains the following displays and fields:

Average No. of Image Blocks per calls - The average number of pages per faxtraffic during the report’s period.

Mean No. of Fax Banks - The mean number of dedicated fax nibbles.

Max. No. of Fax Banks - The maximum allocated nibbles for fax calls.

Number of Fallbacks to VBD - The number of fax calls that were not demodulatedand were, instead, encoded via the ADPCM channel.

Percent Time FEC is Activated - The portion of reported time during which theForward Error Correction algorithm was activated.

Fax Calls

No. of O/G Fax Calls - The number of outgoing fax calls for the report’s duration.

No. of I/C Fax Calls - The number of incoming fax calls for the report’s duration.

Page 136: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

S I T E A N D C L U S T E R W I N D O W O P S - 3 6 0

92050005-04 5-45

No. of S.F. Calls (O/G) - The number of standard fax calls (outgoing).

No. of N.S.F. Calls (O/G) - The number of non-standard fax calls (outgoing).

Local Error Count (FCC) - The number of errors detected in the Local Fax ControlChannel.

Remote Error Count (FCC) - The number of errors detected in the Remote FaxControl Channel.

Undemodulated Fax Blocks

Dem. Shortage - The number of fax calls that were not demodulated due toDemodulator shortage.

Unclassified - The number of fax calls that failed the classification stage.

Fax Bank Shortage - The number of fax calls that were not demodulated due to FaxBank shortage.

NSS Code - The number of fax calls that originated from Non-Standard Systems.

Block - A fax transmission of a duration longer than 3 seconds. This represents thenumber of pages in a transmission.

Percentage of Image Blocks %

The ratio of various speed and protocol fax call types, as part of the total fax traffic.

The window contains the following buttons:

Print/Save - To open the Print/Save Report window.

Exit - To cancel the report display and close its window.

Page 137: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 S I T E A N D C L U S T E R W I N D O W

5-46 92050005-04

Accumulated Busiest Period Report

The Accumulated Busiest Period Report, shown below, is available either as an OnDemand version (for the period between 23:00 and the request time), Last version(for the last complete 24-hour period, or as a From version (for a user-determinedperiod). To open this report, select it and click open report in the Open Reportwindow.

The Report contains the following sections:

Report Header - The top-most line of the report contains the name of the report andthe details of the source of the report (cluster number and terminal number).

No. of Non-Pre-assigned Bearer Channels - This figure is set during the terminal’sconfiguration. Use the BC configuration table in the Pools and Destination categoryin the configuration map to set these values.

No. of Non-Pre-assigned Trunk Channels - A figure is determined during terminalconfiguration (in Trunk Channel Mapping category of the Configuration MapEditor).

Page 138: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

S I T E A N D C L U S T E R W I N D O W O P S - 3 6 0

92050005-04 5-47

Busiest Period - The busiest 15-minute period for the report duration. (Theparameters are sampled and recorded every 15 minutes.)

Bearer Usage

Total DCME Utilization (%) - - The average percentage of BCs (non pre-assigned)which are used for active traffic.

DCME Speech Utilization (%) -The portion of the bearer that is used toaccommodate speech traffic.

Average No. of Clear Nibbles - The number of clear nibbles (4 bits) on the bearer,measured over the report’s period.

Average No. of Bit Banks - This is the number of the bit banks for the entire bearer,measured over the reports period.

Average No. of Fax Banks - The number of the fax banks on the bearer, measuredover the report’s period.

DLC Data - Per Destination.

Voice On (%) - The ratio of the number of of DCME frames during which DLC forvoice/VBD is ON, to the total number of DCME frames.

64 Kbit/s On (%) - The ratio of the number of of DCME frames during which DLCfor 64 Kbit/s is ON, to the total number of DCME frames.

DLC Operations - The total number of DLC procedures initiated during the reportperiod. This is an indication of system over/under utilization and proper resourceallocation.

Daily Accumulated DLC Data - Per Destination.

Voice On Time - Accumulated Voice DLC activation during the report period.

64 Kbit/s On Time - Accumulated Clear Channel DLC activation during the reportperiod.

No. of Operations - Total DLC activation during the report period.

Page 139: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 S I T E A N D C L U S T E R W I N D O W

5-48 92050005-04

Voice Statistics

Average Bit Per Sample (Voice) - The average number of encoding bits per samplefor all connected TCs used for voice.

Worst Bits Per Sample (Voice) - Voice traffic overload and represents the lowestsample used to transmit traffic during the report period.

Average No. of Overloaded Channels - Traffic overload(s). The higher the number,the worse an overload condition experienced by the system.

Voice Activity Ratio (%) - The ratio of the number of non pre-assigned TCs whichare classified as voice-active, to the total number of non pre-assigned TCs.

FOF - Voice Freeze Out Factor (%) - The ratio of competitive clip duration tovoice spurt duration.

Voice Freeze Out Excess (%) - The ratio calculated when the percentage of FOFexceeds 0.5% when averaged over a period of one minute.

Worst Voice Freeze Out - The highest FOF value measure.

Accumulated Peak Values

The data included in this section include both values measured and exact time. Thismay be of help in trying to prepare a terminal activity and traffic loads profile.

Max. Voice Activity Ratio % - The maximum value of the portion of the beareroccupied by speech traffic during the report period that is an indication of speechtraffic load.

Worst Average Bits Per Sample - The worst (lowest) average of BPS for the reportperiod - an indication of speech traffic overload.

Worst Voice Freezeout % - The ratio of the number of non pre-assigned TCsclassified as voice-active but not connected, to the total number of of non pre-assigned TCs classified as voice-active (connected and not connected).

Max. Data Activity Ratio % - This is the maximum value of the portion of thebearer occupied by data traffic during the report period - an indication of data trafficload.

Worst Data Freezeout % - The highest Data-related Freeze Outs that is, anindication of data traffic overload.

Page 140: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

S I T E A N D C L U S T E R W I N D O W O P S - 3 6 0

92050005-04 5-49

Worst No. of Fax Banks - The highest number of Fax Banks allocated on the bearer- an indication of fax traffic loads.

Data Statistics

Data Activity Ratio (%) - The ratio of the number of non pre-assigned TCs whichare classified as data-active, to the total number of non pre-assigned TCs.

Data Freeze Out (%) - The ratio of non-pre-assigned Trunk Channels classified asdata active but not connected, to the total number of non-pre-assigned TCs classifiedas data active.

Worst Data Freeze Out (%) - The highest Data Freeze Out Factor (FOF) valuemeasured for the report period.

64 Kbit/s Statistics

64 Kbit/s Connected Ratio (%) - The ratio of the number of non pre-assigned TCswhich are classified as 64 Kbit/s, to the total number of non pre-assigned TCs.

64 Kbit/s Failed Seizure Ratio (%) - Percentage of 64 Kbit/s on-demand seizureattempts that receive a 64 Kbit/s negative acknowledgment from the DCME.

Fax Calls

Relative fax traffic loads per destination.

No. of Outgoing Fax Calls - Number of outgoing fax calls.

No. of Incoming Fax Calls - Number of incoming fax calls.

Accumulated Fax Calls

Max. No. of O/G Fax Calls - This field includes the time and number of peakOutgoing fax traffic.

Max. No. of I/C Fax Calls - This field includes the time and number of peakIncoming fax traffic.

Page 141: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 S I T E A N D C L U S T E R W I N D O W

5-50 92050005-04

Accumulated Primary Rate Error Performance Report

The Accumulated Primary Rate Error Performance Report, shown below, is availableeither as an On Demand, Last or From version. To open this report, select it and clickopen report in the Open Report window.

From - The starting date, day and time for the accumulation of the displayed report.

The operator-configured EPI (Error Performance Interval) is displayed below the report’stime and terminal of origin. The report’s main display section is per-clique, per-destination within a clique.

Beneath the Standard field, a button appears. This button allows you to choose eitherNear End or Far End. The report will be displayed accordingly.

The Report window displays the following for each trunk and bearer:

ESR - Errored Second Ratio. The ratio of ES to total seconds in available timeduring a fixed measurement interval.

Page 142: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

S I T E A N D C L U S T E R W I N D O W O P S - 3 6 0

92050005-04 5-51

SESR - Severely Errored Second Ratio. The ratio of SES to total seconds inavailable time during a fixed measurement interval. A one-second period containingat least 30% errored blocks.

BBER - Background Block Error Ratio. The ratio of Background Block Errors tototal blocks in available time during a fixed measurement interval. (The count of totalblocks excludes all blocks during SESs.)

UAS - Unavailable Seconds.

SLIP Tx - Seconds with slip (mismatched times at different clocks) at the Txinterface

SLIP Rx - Seconds with slip (mismatched times at different clocks) at the Rxinterface

Note: Slip Tx and Rx measurements appear only in Near-End reports.

The window contains the following buttons:

Print/Save - To open the Print/Save Report window.

Exit - To cancel the report display and close its window.

Page 143: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 S I T E A N D C L U S T E R W I N D O W

5-52 92050005-04

Accumulated Fax Statistics Report

The Accumulated Fax Statistics report, shown below, is available either as an OnDemand version (for the period between 23:00 and the request time), Last version(for the last complete 24-hour period, or as a From version (for a user-determinedperiod). To open this report, select it and click open report in the Open Reportwindow.

The Report contains the following sections:

Report Header - The top-most line of the report contains the name of the report andthe details of the source of the report (cluster number and terminal number).

From - The starting date, day and time for the accumulation of the displayed report.

The operator-configured FSTI (Fax Statistics Time Interval) is displayed below thereport’s time and terminal of origin. The report’s main display section is per-clique,per-destination within a clique. The report’s main display contains the followingfields:

Average No. of Image Blocks per Call - The average number of pagestransmitted/received per fax call.

Mean No. of Fax Banks - The statistical mean for usage of Fax Banks. Use thisnumber to assess fax traffic loads compared to resources availability.

Page 144: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

S I T E A N D C L U S T E R W I N D O W O P S - 3 6 0

92050005-04 5-53

Max. No. of Fax Banks - The maximum number of Fax Banks used by the terminalfor the report period. Use this number to assess peak fax traffic loads compared toresources availability.

Number of Fallbacks to VBD - The number of fax calls that were transferred asVBD.

Percent Time FEC is Activated - An indication of the proportional use of ForwardError Correction

Fax Calls

No. of Outgoing fax calls

No. of Incoming fax calls

No. of S.F. calls (O/G) - The number of Outgoing Standard (calls between machinesof different makes) fax calls.

No. of N.S.F. calls (O/G) - The number of Outgoing Non-Standard (calls betweenmachines of same make) fax calls.

Local Error Count (FCC) - The percentage of errored Near-End transmissions.

Remote Error Count (FCC) - The percentage of errored Far-End transmissions.

Undemod. Fax Blocks

The reasons for transmitting fax calls as undemodulated traffic (throughADPCM/LD-CELP). This field contains several sub-fields:

Demodulators Shortage - An indication of traffic overload and/or a shortage of Faxcards.

Unclassified - An indication of the number of calls that the system could not classifyclearly as fax calls.

Fax Bank Shortage - An indication of an overloaded bearer.

NSS Code - This is an indication of the number of fax calls that originated withmachines not supported by the system. These calls are transmitted thoughADPCM/LD-CELP.

Page 145: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 S I T E A N D C L U S T E R W I N D O W

5-54 92050005-04

Percentage of Image Blocks (%)

A table that contains percentage of Outgoing and Incoming calls for the available faxprotocols. Use this table to analyze fax traffic profiles.

Page 146: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

S I T E A N D C L U S T E R W I N D O W O P S - 3 6 0

92050005-04 5-55

Accumulated Control Channel Error Performance ReportThe Accumulated Control Channel Error Performance Report, shown below,contains accumulated CC Error data for bearer traffic. To open this report, select itand click open report in the Open Report window.

The Report window contains following displays and fields:

From - The report’s date and the time.

Statistic Interval - A display to inform the user of the pre-determined interval thatpasses between updates of the requested report.

The report’s table contains the following information about the assigned destination(s):

• Average BER - The ratio of the number of bit errors identified in the controlchannel during the STI over the total number of bits received in the controlchannel times the number of minutes in the STI.

• BER Excess (%) - The percentage ratio of the time during which the average BERexceeds 10E-3 over the CC Bits per One minute times the number of STI minutes.

• Unavailable Seconds (%) - The percentage ratio of the period of unavailableseconds during an STI period over the number of second in the STI (see G.821).

• Severely Errored Seconds (%) - The percentage ratio of available seconds withan error rate bigger than 10E-3 over the number of seconds in the STI. Availableis defined according to ITU G.821.

• DCME Frame Alarm Sec - The number of seconds during which a DCMEframe alarm was activated.

The window contains the following:

Print/Save- To open the Print/Save Report windowExit - To close the Report window and return to the Cluster window.

Page 147: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 S I T E A N D C L U S T E R W I N D O W

5-56 92050005-04

Print/Save Report

The Print/Save Report window is displayed by pressing the Print/Save button in theOpen Reports window. It is used to set the required parameters for theprinting/saving of a selected report.

The Print/Save Report window contains the following fields and displays:

• Report - The report selected for printing or for saving to a file.

• From - The starting date and time of the required report.

• To - Using the Day and Time pull-down menus, select the latest date and time tobe covered by the requested report.

• Default Printer - The default printer selected as the output device for the report.

The window contains the following buttons:

Save to File - To open a secondary window to set the parameters of the file whichthe report will be saved as.

Print - To initiate printing of the selected report.

Preview - Click this button to see a monitor preview of the report prior to printing it.

Cancel - To cancel the Print/Save operation and close the Print/Save Reportwindow.

ACO - Alarm Cut off

If an audio alarm is activated by a terminal in the cluster, click once the ACO optionto turn it off. It is also possible to turn off an activated alarm by clicking once on theACO Tool Icon, located below the Cluster window of pull down menus.

Page 148: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

92050005-04 6-1

Database Files

! "" " # !! " $ % & " ! "" " ' ( $)!&! ("! *(+! """"

! "dbfConfig ,-.-% /

File ManagementThe DBF files generated by the OPS are stored at a pre-defined directory at the OPS-360 station. The directory name may be set through the dbfConfig application.

DBF files are collected from the OPS-360 station by the third party system, throughFTP, for example. DBF files must be removed periodically (according to the settime interval) in order to save disk space.

Note : While the OPS-360 writes information to DBF files, these files cannot be accessed. Allinaccessible DBF files will carry the extension *.pre , indicating that they are currently being prepared.The database files may be accessed once the extension changes to *.dbf .

File StructureEach report has its own set of DBF files. Each DBF file includes the report recordsfrom the specified time interval at all the terminals at the site. The number ofrecords per report within the time interval depends on the STI value defined for theterminal configuration.

Page 149: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 I N T R O D U C T I O N

6-2 92050005-04

File NamesReport information is composed of Main and Trailer DBF files. A complete trafficreport consists of 3 files: Traffic Main, Traffic Cliques and Traffic Destinations.

Note: It is advisable to download Trailer files only with the appropriate Main files.

These files include the following:

Main - General report information

Cliques - Clique information

Destinations - Destination information

The file names are 16-18 characters long, ending with the extension .dbf. Files arenamed according to the following convention: <report_type><time>.dbf.

The following is an example of traffic report types:

Report Name <report_type>

Traffic Statistics - Main

Traffic Statistics - Clicques

Traffic Statistics - Destinations

tra_

tra_c_

tra_d_

FAX Statistics - Main

FAX Statistics - Clicques

FAX Statistics - Destinations

fax_

fax_c_

fax_d_

Bearer CC - Main

Bearer CC - Destinations

bcc_

bcc_d_

Busiest Period - Main

Busiest Period - Clicques

Busiest Period - Destinations

bus_

bus_c_

bus_d_

Error Performance - Main

Error Performance - Bitstream

err_

err_b_

Event Log eve_

Page 150: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

I N T R O D U C T I O N O P S - 3 6 0

92050005-04 6-3

The time interval is written thus: yyyymmddHHMM, where ymd are the year, monthand date. HM are the hour and minute.

File ContentsThe DBF files contain only relevant information. Each table has a “Null value” fieldthat assigns a value for inapplicable fields.

Note: Column names are limited to 10 characters in DBF format.

Page 151: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

92050005-04 A-1

OMCP Monitor Reports Session

OMCP Monitor Reports Session on theOPS-360The OMCP Monitor Report Session allows the OPS-360 operator to generate andproduce various reports relating to the status of the terminals. The operator may alsoobtain information about routine requirements, system statistics, and various types ofmalfunctions.

The OPS Monitor enables the OPS-360 operator to view OMCP monitor applicationwindows. These windows may be viewed on any monitor directly connected to theOMCP card.

This appendix includes all of the OMCP Monitor Reports available for viewing andprovides instructions for the OPS-360 operator on how to open a report, close areport, display other reports, and return to the Main Menu.

Refer to Chapter 5, Site and Cluster Window for detailed descriptions andexplanations regarding the specific fields and terms used in each report.

A

Page 152: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 A P P E N D I X A

A-2 92050005-04

Opening an OMCP Monitor Reports SessionTo open an OMCP Monitor Reports Session:

1. In the OPS-360 Monitor, click a cluster in the Site window; the Cluster windowof the OPS-360, in the case of the figure below, a cluster of four OPS-360terminals, is displayed.

2. From the Cluster window, select a specific terminal.

3. From the Menu Bar of the Cluster window, choose Terminal .

4. From the Terminal pull-down menu, click the option Open OMCP Monitor ;the OMCP Monitor window opens:

Page 153: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

A P P E N D I X A O P S - 3 6 0

92050005-04 A-3

At the OMCP prompt, type reports and press ENTER; the DTX-360 ReportsMain Menu window opens.

Page 154: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 A P P E N D I X A

A-4 92050005-04

DTX-360 Reports Main MenuThe DTX-360 Reports Main Menu allows you to access reports relating to the statusof the selected terminal.

To display information concerning a specific report, type the window number of thereport and press ENTER.

DTX-360 Reports

A brief description follows for each of the reports listed in the DTX-360 ReportsMain Menu.

In addition, instructions are provided for the OPS-360 operator on how to open areport, close a report, display other reports, and return to the Main Menu.

Page 155: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

A P P E N D I X A O P S - 3 6 0

92050005-04 A-5

DTX-360 Status Reports

The DTX-360 Status Reports window, shown below, displays the status of thecurrent terminal, including its configuration and alarm level. It is an online report,constantly updated in real time.

To return to the Reports Main Menu window, press the SPACE bar.

Page 156: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 A P P E N D I X A

A-6 92050005-04

Alarm Summary Reports

The Alarm Summary Report window, shown below, provides a summary of thestatus of all the currently active alarms. It is an online report, constantly updated inreal time.

To return to the Reports Main Menu window, press the SPACE bar.

Page 157: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

A P P E N D I X A O P S - 3 6 0

92050005-04 A-7

Transmission & Control Channel Check Alarms

The Transmission and Control Channel Check Alarms Report window, shownbelow, displays the status of all Transmission and Control Channel Alarms. It is anonline report, constantly updated in real time.

To continue viewing the report, press the SPACE bar.

The following alarms appear in the subsequent screens:

Remote TC

CSV

PCM

To progress to the next screen, press the SPACE bar.

To return to the Reports Main Menu, press the SPACE bar.

Page 158: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 A P P E N D I X A

A-8 92050005-04

Event Reports

The Event Reports window, shown below, provides a current log of all the eventsand alarms affecting the terminal. It is an online report, constantly updated in realtime.

To return to the Reports Main Menu, press the SPACE bar.

Page 159: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

A P P E N D I X A O P S - 3 6 0

92050005-04 A-9

History Reports

The History Reports window, shown below, provides a log of all the events andalarms affecting the terminal up to the moment of viewing.

To continue viewing the report, press the SPACE bar.

Note : If the window indicates **last page** , press the SPACE bar to return to the ReportsMain Menu.

Page 160: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 A P P E N D I X A

A-10 92050005-04

Erase History Reports

The Erase History Reports option allows the operator to delete the log of all eventsand alarms contained in the History Reports.

To delete information from the History Reports, go to the Reports Main Menu andtype 6 ( “Erase History ” ) .

The confirm that the information has been deleted, type 5 (“History”). The HistoryReport will not contain any report information.

Channel Check Reports

For future implementation.

Page 161: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

A P P E N D I X A O P S - 3 6 0

92050005-04 A-11

Traffic Statistics Reports

The Traffic Statistics Alarm Reports window, shown below, displays informationabout traffic of the terminal and the status of the statistics alarms ( i.e., whether ornot they have exceeded their thresholds for each clique and for each destination).

To return to the Reports Main Menu, press the SPACE bar.

Page 162: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 A P P E N D I X A

A-12 92050005-04

Fax Statistics Reports

The Fax Statistics Report window, shown below, contains information about the faxtraffic activity of the terminal.

To continue viewing the report, press the SPACE bar.

Page 163: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

A P P E N D I X A O P S - 3 6 0

92050005-04 A-13

The Fax Statistics Report is then displayed as follows:

To return to the Reports Main Menu, press the SPACE bar.

Page 164: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 A P P E N D I X A

A-14 92050005-04

Fax Statistics Reports (On Demand)

The Fax Statistics Report (On Demand) window, shown below, allows the operatorto access information about the status of fax transmissions up to the time of therequest.

To continue viewing the report, press the SPACE bar.

Page 165: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

A P P E N D I X A O P S - 3 6 0

92050005-04 A-15

The Fax Statistics Report (On Demand) is then displayed as follows:

To return to the Reports Main Menu, press the SPACE bar.

Page 166: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 A P P E N D I X A

A-16 92050005-04

Busiest Period Reports

The Busiest Period Report window, shown below, displays information regardingthe busiest periods of traffic for the report duration. The report is constantly updatedin real time and is available in three versions:

On Demand version - for the period between 23:00 and the request time

Last version - for the last complete 24 hour period

From version - for a user-determined period

To continue viewing the report, press the SPACE bar.

Page 167: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

A P P E N D I X A O P S - 3 6 0

92050005-04 A-17

The Busiest Period Report is then displayed as follows:

To continue viewing the report, press the SPACE bar on the keyboard.

Page 168: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 A P P E N D I X A

A-18 92050005-04

The Busiest Period Report is then displayed as follows:

To return to the Reports Main Menu, press the SPACE bar.

Page 169: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

A P P E N D I X A O P S - 3 6 0

92050005-04 A-19

Statistics Threshold Alarm Report

For future implementation.

Primary Error Performance Reports

The Primary Rate Error Performance Report window, shown below, containsinformation about errors at the terminal. To open this report, select it and click openreport in the Open Report window.

To view the Interval Report , press 1.

The Interval Report appears.

To view the Daily Report, press 2.

The Daily Report appears.

Page 170: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 A P P E N D I X A

A-20 92050005-04

Control Channel Error Performance Reports

The Control Channel Error Performance Report, shown below, displaysinformation about assigned destinations and bearer error performance statistics.

To return to the Reports Main Menu, press the SPACE bar.

Page 171: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

A P P E N D I X A O P S - 3 6 0

92050005-04 A-21

Built-in Test (BIT)

The Built-in Test Report window, shown below, displays information regardingbuilt-in tests of the DTX-360.

The Built-in Test (BIT) circuits and software are the main tools used by the cards forself-regulation and trouble-shooting.

The BIT enables automatic identification of any failed card in the system. The BIToutputs are used to trigger actions such as management reports, redundancyswitching, system reset, maintenance, alarms, etc.

Three Built-in Test Reports are available for viewing:

Init BIT

Communication BIT

Online BIT

Viewing options for accessing each type of report appear at the bottom of thewindow.

To view a desired option, type the number and press ENTER.

To exit and return to the Reports Main Menu, type 0 and press ENTER.

Page 172: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 A P P E N D I X A

A-22 92050005-04

Init Bit Results Window

To view the Init BIT Results window, shown below, type 1 in the Built-in TestReport window and press ENTER.

To view the Init BIT results of a particular card, type the number of the card andpress ENTER.

Page 173: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

A P P E N D I X A O P S - 3 6 0

92050005-04 A-23

The Init BIT results of a particular card, for example Card 18 (ADPC-RX) shownbelow, appear in the window.

To view the Init BIT results of another card:

1. Return to the Init Bit Results window by pressing any key.

2. Type the number of the card and press ENTER.

To return to the Built-in Test Report main window:

1. Return to the INIT BIT Results window by pressing any key.

2. Type 0 and press ENTER.

Page 174: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 A P P E N D I X A

A-24 92050005-04

The Init BIT results of a card, for example Card 4 (TDSP_0) shown below, mayappear on more than one window. To continue viewing, press any key and ENTERor press the SPACE bar.

When the last window appears, pressing any key and ENTER or pressing theSPACE bar will return you to the Init BIT Results window.

Page 175: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

A P P E N D I X A O P S - 3 6 0

92050005-04 A-25

Communication Bit Results Window

To view the Communication BIT Results window, return to the Built-in Test Reportmain window, type 2, and press ENTER. The window below appears.

Page 176: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 A P P E N D I X A

A-26 92050005-04

Press the SPACE bar to view the next window.

Press the SPACE bar to return to the Built-in Test Report main window.

Page 177: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

A P P E N D I X A O P S - 3 6 0

92050005-04 A-27

Online BIT Results Window

To view the Online BIT Results window, return to the Built-in Test Report mainwindow, type 3, and press ENTER. The window below appears.

To view the Online BIT Results of a particular card, type the number of the card andpress ENTER.

Page 178: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 A P P E N D I X A

A-28 92050005-04

For example, to view the test results of the SIGN card, type 18 in the Online BITResults window, and press ENTER. The window, shown below, appears andpresents you with a list of options.

To view details of the Online BIT Results of the selected card, type D and pressENTER.

To view the Online BIT Help window, type H and press ENTER.

To print statistics, type S and press ENTER.

To get statistics, type G and press ENTER.

A window briefly appears with the message NEW OBIT STATISTICS ON THE WAYand an updated Details window opens.

To exit and return to the Online BIT Results window, press SPACE or type 0 andpress ENTER.

To exit and return to the Built-in Test Report window from the Online BIT Resultswindow, type 0 and press ENTER.

Page 179: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

A P P E N D I X A O P S - 3 6 0

92050005-04 A-29

To view details of the Online BIT Tests Results of the selected card, in this case theSIGN card, type D, and press ENTER; the window below opens.

To exit and return to the Online BIT Results window, type 0 and press ENTER.

To exit and return to the Built-in Test Report from the Online BIT Results window,type 0 and press ENTER.

To exit and return to the Reports Main Menu window from the Built-in Test Reportwindow, type 0 and press ENTER.

The Online BIT Help window provides you with a list of codes for the Online BIT.

Page 180: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 A P P E N D I X A

A-30 92050005-04

To view the Online BIT Help window, type H and press ENTER; the window belowopens.

To exit the Online BIT Help window and return to the Details window, press theSPACE bar.

Page 181: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

A P P E N D I X A O P S - 3 6 0

92050005-04 A-31

The Online BIT Statistics window provides you with a list of statistics about theBuilt-in Test.

To view the Online BIT Statistics window, type S and press ENTER; the windowbelow opens.

To exit the Online BIT Statistics window and return to the Details window, press theSPACE bar.

Page 182: OPS-360 Operator Station User's Guide - Salvex OPS Users Guide.pdf · responsibility is assumed by ECI Telecom for its use nor for rights of third parties which may result from its

O P S - 3 6 0 A P P E N D I X A

A-32 92050005-04

Closing the OMCP Monitor WindowTo close the OMCP Monitor window:

1. With the cursor in any of the reports windows, type quit .

2. Press ENTER.