Operation Manual NEW BENCHMARK OF MEASURING · CA700 c. Silica-gel Protector d. AA Batteries e....

2
S i n c e 1 9 7 7 PRECASTER PRECASTER ENTERPRISES CO., LTD. Add:No.204, Sec. 2, Fu-Hsing Rd., Taichung, Taiwan Tel:886-4-2262 1000. FAX:886-4-2261 6565 http://www.precaster.com.tw e-mail:[email protected] Please contact your local dealer for further assistance, thank you. Service Support Warranty Error Code Code Err01 Err02 Err03 Err04 Err05 Err06 Err07 Description Out of measuring range Reflected signal is too weak Out of display range (max value: 99999), e.g: result of area or dimension is out of display range. Pythagorean calculation error Low Battery Out of working temperature Ambient light is too strong Solution Measure in a proper range Select a better surface Divide calculation into intermediate steps Check and verify values and steps are correct Install a new battery Measure in an environment within specified working temperature Measure in a darker place (shadow target) NEW BENCHMARK OF MEASURING 5 6 CA770 Operation Manual Measuring Function Please press once for enabling Area measuring. Laser will be activated when entering Area measuring Follow the instructions on main screen to measure width and length. Once you finish all instructions, Area is showed on screen. To change display unit, hold Standby Screen Standby Screen Area Measuring Screen Area Measuring Screen Area Measuring Instructions 1 1 2 2 3 3 1 1 3 3 1x2=A Press twice to enter volume measuring. Laser will be avtivated when entering Volume measuring. Follow the instructions on main screen to measure width, length and height. Once you finish all instructions, volume is showed on screen. To change display unit, hold Volume Measuring Screen 2 2 Volume Measuring Instructions 1x2x3=V Stake-out Set your stake and easily get notified when using Dyna-Measuring. 1. Press three times to edit length of Stake. 3. Press to increase your value. 4. Press to decrease your value. 5. Press to shift between numbers 6. When value is decided, press to finish setting. 7. To restore zero, press HANS provide Stake-out function to accelerate your measuring jobs. a. Setting b. Measuring with Stakes 1. When in Dyna-measuring mode, You could notice arrows will be appeared at the left side of number. 2. Follow the arrow, you could get every stakes you need. 3. When approaching to set Stakes, it will alert you by beeping. Press to enter Indirect measuring. 2 2 2 All the calculation is based on Pythagorean theorem (a +b =c ) to measure height indirectly. Laser will be activated when entering Indirect measuring. Follow the instructions on screen to get slang range, horizon range then the height will be displayed on screen. For Pythagorean II (summary of two height) and III (different of two height) are advanced calculating based on Pythagorean I Second Press for Double Pythagoras (Substract) Second Press for Double Pythagoras (Summary) First Press for Single Pythagoras HANS provide a well design memory recall funciton, you could recall memory by hold . The last 20 measures will be displayed on screen, To look up records press to move up, for move down Memory Recall Back-Light switch & Laser pointer switch To Enable and Disable back-light for HANS, press To enable Laser Pointer, hold Also laser icon will also display continuously. Continously display for indicating Laser Pointer is activated a. Area Measurement b. Volume Measurement c. Indirect Measurement P-HC-770 -1011 EM SX1O SX1O NEW BENCHMARK OF MEASURING S i n c e 1 9 7 7 PRECASTER Whole new engine, Faster, Better, no Doubt !! Whole new engine, Faster, Better, no Doubt !! Read carefully before use Operation Manual 0.05m~70m CA770 CA770 Laser Distance Meter Laser Distance Meter TICK-TOCK MEASURING RIGHT IN YOUR HANS TICK-TOCK MEASURING RIGHT IN YOUR HANS Next generation has arrived, Yet a new Benchmarking Next generation has arrived, Yet a new Benchmarking

Transcript of Operation Manual NEW BENCHMARK OF MEASURING · CA700 c. Silica-gel Protector d. AA Batteries e....

  • S i n c e 1 9 7 7

    PRECASTER PRECASTER ENTERPRISES CO., LTD.Add:No.204, Sec. 2, Fu-Hsing Rd., Taichung, Taiwan

    Tel:886-4-2262 1000. FAX:886-4-2261 6565

    http://www.precaster.com.tw

    e-mail:[email protected]

    Please contact your local dealer for further assistance, thank you.

    Service Support Warranty

    Error Code

    Code

    Err01

    Err02

    Err03

    Err04

    Err05

    Err06

    Err07

    Description

    Out of measuring range

    Reflected signal is too weak

    Out of display range (max value: 99999),

    e.g: result of area or dimension is out

    of display range.

    Pythagorean calculation error

    Low Battery

    Out of working temperature

    Ambient light is too strong

    Solution

    Measure in a proper range

    Select a better surface

    Divide calculation into intermediate steps

    Check and verify values and steps are correct

    Install a new battery

    Measure in an environment within specified

    working temperature

    Measure in a darker place (shadow target)

    NEW BENCHMARK OF MEASURING

    5 6

    CA770 Operation Manual

    Measuring Function

    ‧Please press once for enabling Area measuring.

    ‧Laser will be activated when entering Area measuring

    ‧Follow the instructions on main screen to measure

    width and length.

    ‧Once you finish all instructions, Area is showed on screen.

    ‧To change display unit, hold Standby Screen

    Standby Screen

    Area Measuring Screen

    Area Measuring Screen

    Area Measuring Instructions

    11 22 33

    11 33

    1x2=A

    ‧Press twice to enter volume measuring.

    ‧Laser will be avtivated when entering Volume measuring.

    ‧Follow the instructions on main screen to

    measure width, length and height.

    ‧Once you finish all instructions,

    volume is showed on screen.

    ‧To change display unit, hold

    Volume Measuring Screen

    22

    Volume Measuring Instructions1x2x3=V

    Stake-out

    ‧Set your stake and easily get notified when using Dyna-Measuring.

    1. Press three times to edit length of Stake.

    3. Press to increase your value.

    4. Press to decrease your value.

    5. Press to shift between numbers

    6. When value is decided, press to finish setting.

    7. To restore zero, press

    HANS provide Stake-out function to accelerate your measuring jobs.

    a. Setting

    b. Measuring with Stakes

    1. When in Dyna-measuring mode,

    You could notice arrows will be appeared at the

    left side of number.

    2. Follow the arrow, you could get every stakes you need.

    3. When approaching to set Stakes, it will alert you by beeping.

    ‧Press to enter Indirect measuring.2 2 2

    ‧All the calculation is based on Pythagorean theorem (a +b =c ) to measure height indirectly.

    ‧Laser will be activated when entering Indirect measuring. Follow the instructions on screen to get slang range,

    horizon range then the height will be displayed on screen.

    ‧For Pythagorean II

    (summary of two height)

    and III (different of two

    height) are advanced

    calculating based on

    Pythagorean I

    Second Press for Double Pythagoras (Substract)

    Second Press for Double Pythagoras (Summary)

    First Press for Single Pythagoras

    ‧HANS provide a well design memory recall funciton, you could

    recall memory by hold .

    ‧The last 20 measures will be displayed on screen, To look up

    records press to move up, for move down

    Memory Recall

    Back-Light switch & Laser pointer switch ‧To Enable and Disable back-light for HANS, press

    ‧To enable Laser Pointer, hold

    Also laser icon will also display continuously.

    Continously display for

    indicating Laser

    Pointer is activated

    a. Area Measurement

    b. Volume Measurement

    c. Indirect Measurement

    P-HC-770 -1011EM

    SX1OSX1O

    NEW BENCHMARK OF MEASURING

    S i n c e 1 9 7 7

    PRECASTER

    Whole new engine,Faster, Better, no Doubt !!Whole new engine,Faster, Better, no Doubt !!

    Read carefully before use

    Operation Manual

    0.05m~70m

    CA770CA770 Laser Distance MeterLaser Distance Meter

    TICK-TOCK MEASURING

    RIGHT IN YOUR

    HANS

    TICK-TOCK MEASURING

    RIGHT IN YOUR

    HANS

    Next generation has arrived,Yet a new Benchmarking

    Next generation has arrived,Yet a new Benchmarking

  • NEW BENCHMARK OF MEASURING

    1 2

    CA770 Operation Manual

    ‧Thanks for choosing Precaster HANS (CA Series). Please read safety instruction carefully.

    ‧Laser radiation is emitted from this product. Use of controls, adjustment procedures other

    than those specified herein may result in laser radiation exposure.

    Never stare directly into beam or aim the laser beams at others.

    ‧HANS contains semiconductor laser diodes with wavelengths of 650 nanometers.

    ‧The total continuous output of the beams never exceeds 1.0 milli-watts.

    ‧HANS complies with EMC Test according to EN61000-6-3 :

    2001+A11:2004, EN 61000-6-1:2001, EN 61000-4-2, EN 61000-4-3,

    EN 60825, FCC Test according to PART 15

    ‧Thanks for choosing Precaster HANS (CA Series). Please read safety instruction carefully.

    ‧Laser radiation is emitted from this product. Use of controls, adjustment procedures other

    than those specified herein may result in laser radiation exposure.

    Never stare directly into beam or aim the laser beams at others.

    ‧HANS contains semiconductor laser diodes with wavelengths of 650 nanometers.

    ‧The total continuous output of the beams never exceeds 1.0 milli-watts.

    ‧HANS complies with EMC Test according to EN61000-6-3 :

    2001+A11:2004, EN 61000-6-1:2001, EN 61000-4-2, EN 61000-4-3,

    EN 60825, FCC Test according to PART 15

    Before Start Using

    Change of Battery

    ‧HANS is powered by 2 x AA Batteries

    ‧Battery status will be showed in initial screen.

    ‧In case if battery icon display continuously,

    it shows battery is about 1,000 measure times left.

    ‧Low power indicator will be twinkling when battery is low.

    ‧To change new batteries, remove back lid and observing correct

    polarity when install new batteries, then close back lid.

    Specification

    Overview for CA770

    Power Button / Clear

    Reference Switch

    / Laser pointer

    Receive Window

    Battery Cover

    Pin Tail

    J.

    K.

    L.

    M.

    N.

    A.

    B.

    C.

    D.

    E.

    F.

    G.

    H.

    I.

    LCD

    Add / Unit Switch

    Measure / Dyna-Measure

    Measure Function

    Area

    Dimension

    Stake-Out

    Countdown Measure / Memories

    Strap Holder

    Laser Emitting Window

    Subtract / Back-Light

    Pythagoras I, II & III

    A

    B

    C

    D

    E

    F

    H

    J

    I

    G

    N

    L

    KM

    Overview for Screen

    23

    5

    7

    6

    11

    101

    8

    9

    12

    13

    4

    1. Laser Indicator

    2. Indirect Measuring

    Single Pythagoras

    Summary of two Pythagoras

    Subtract of two Pythagoras

    3. Measuring Function

    Area Measuring

    Volume Measuring

    4. Measuring Reference

    5. Add and Subtract

    6. Maximum display

    7. Minimum display

    8. Stakes Direction Indicator

    9. Main Screen and units

    10. Countdown Measuring

    11. Memories

    12. Battery Status

    13. Sub-Screen and units

    a. Carrying case

    b. CA700

    c. Silica-gel Protector

    d. AA Batteries

    e. Safety Strap

    f. Engineering Pencil

    g. Operation manual

    Measure Range*

    Resolution

    Accuracy*

    Measure Speed*

    Laser Type

    Beam Size

    Battery

    Battery Life

    Dimension

    Operation Temperature

    Storage Temperature

    Automatic switch-off

    -Laser

    -Device

    *The working range and accuracy depend on how well the energy of laser is reflected from surface

    (mostly comes from scattered light) and the target reflectivity. The brightness of laser point to

    ambient light intensity or use a target plate (Kodak White) may helps for increasing the working range and the stability of accuracy.

    *In favorable condition, accuracy could be in ±1.5 mm(2δ) and a deviation influence of ±0.25mm/m must be taken into count after ten meters.

    *In unfavorable condition, such as bright sunlight, rough surface, very short distance, or a poor and extra strong reflected signal may cause the deviation reach or

    over ±10mm and also may bring an ambiguous cycle which may lead the measures to an unexpected result..

    All Accessories

    0.05M~70M

    0.001M

    ±1.5mm

    0.5 sec.

    650 nm, Class 2,