Operation Manual for SDH

download Operation Manual for SDH

of 417

Transcript of Operation Manual for SDH

  • 8/14/2019 Operation Manual for SDH

    1/416

    1 Quick Start 1-1.....................................................................................................

    1.1 Starting and Shutting down T2000 1-2.........................................................

    1.1.1 Starting T2000 Computer 1-2...............................................................

    1.1.2 Shutting down T2000 Computer 1-4....................................................1.1.3 Starting T2000 Server 1-5....................................................................

    1.1.4 Exiting T2000 Server from System Monitor 1-6...................................

    1.1.5 Exiting T2000 Server from T2000 Client 1-6........................................

    1.1.6 Restarting T2000 Server 1-7................................................................

    1.1.7 Starting T2000 Client 1-8.....................................................................

    1.1.8 Exiting T2000 Client 1-9.......................................................................

    1.1.9 Switching T2000 User 1-10....................................................................

    1.2 Verifying whether License File has been Installed Correctly 1-11..................

    1.3 Opening Online Help 1-12..............................................................................1.4 Closing Online Help 1-14................................................................................

    1.5 System Setting 1-15.......................................................................................

    1.5.1 Enabling Display of Needed Functions 1-15..........................................

    1.5.2 Setting Alarm Sounds 1-16....................................................................

    1.5.3 Setting View Background 1-17...............................................................

    1.5.4 Setting Screen Lockout 1-18..................................................................

    1.5.5 Changing NM Users Password 1-20.....................................................

    1.6 Views 1-21......................................................................................................

    1.6.1 Main Topology 1-21...............................................................................

    1.6.2 Equipment Maintenance Console 1-22..................................................

    1.6.3 Protection View 1-23..............................................................................

    1.6.4 Trail View 1-24.......................................................................................

    1.6.5 Clock View 1-25.....................................................................................

    1.6.6 DCN View 1-26......................................................................................

    1.6.7 Custom View 1-27..................................................................................

    1.6.8 NE Panel 1-30........................................................................................

    1.7 Selecting Operation Objects from Object Tree 1-32.......................................1.8 Setting Parameters in the List 1-33................................................................

    1.9 Operation Precautions 1-34............................................................................

    2 Creating Topology 2-1........................................................................................

    2.1 Creating NEs 2-2..........................................................................................

    2.1.1 Searching NEs in Batch 2-2.................................................................

    2.1.2 Manually Creating NEs 2-3..................................................................

    2.1.3 Deleting NE 2-4....................................................................................

    2.1.4 Switching NE User 2-5.........................................................................

    2.1.5 Creating Topology Subnet 2-6.............................................................

  • 8/14/2019 Operation Manual for SDH

    2/416

    2.2 Changing NE Attributes 2-8..........................................................................

    2.2.1 Changing NE Name and Remarks 2-8.................................................

    2.2.2 Changing NE IP Address 2-9...............................................................

    2.2.3 Changing NE Extended ID 2-10.............................................................

    2.2.4 Changing NE Subnet Mask 2-11............................................................

    2.2.5 Changing NE Pre-configuration Attribute 2-12.......................................

    2.3 Creating Links 2-13........................................................................................

    2.3.1 Creating Fiber/Cable 2-13......................................................................

    2.3.2 Deleting Fiber 2-14.................................................................................

    2.3.3 Creating NM Ethernet Line 2-16............................................................

    2.3.4 Creating Extended ECC 2-16.................................................................

    2.3.5 Creating Serial Port Line 2-17................................................................

    2.4 Creating NM 2-19...........................................................................................

    3 Security Management 3-1...................................................................................

    3.1 Creating NE User and Assigning Authority 3-2............................................

    3.2 Managing NE Login 3-3................................................................................

    3.2.1 Switching NE User 3-3.........................................................................

    3.2.2 Forcing NE User to Log out NE 3-4.....................................................

    3.2.3 Locking NE Login 3-4...........................................................................

    3.2.4 Locking NE Settings 3-5.......................................................................

    3.2.5 Setting NE Security Parameters 3-6....................................................

    3.2.6 Browsing NE Security Log 3-7.............................................................

    3.3 Creating NM User 3-9...................................................................................

    3.3.1 Adding Operation Set 3-9.....................................................................

    3.3.2 Adding Equipment Set 3-10...................................................................

    3.3.3 Adding NM User Group 3-11..................................................................

    3.3.4 Modifying Authority of NM User Group 3-11..........................................

    3.3.5 Creating NM User and Assign Authority 3-13........................................

    3.3.6 Slightly Adjusting Authority of NM User 3-14.........................................

    3.3.7 Modifying General User Attribute 3-15...................................................3.3.8 Enabling Remote Maintenance User 3-16.............................................

    3.4 Managing T2000 Login 3-17...........................................................................

    3.4.1 Locking T2000 Client Screen 3-17.........................................................

    3.4.2 Switching NM User 3-17........................................................................

    3.4.3 Switching Between Single User Mode and Multi-user Mode 3-17.........

    3.4.4 Forcing Other Users to Exit T2000 3-18................................................

    3.4.5 Modifying NM Users Password 3.....................................................

    4 Configuring Equipment 4-1................................................................................

    4.1 Creating and Viewing Physical Location Information 4-3.............................

  • 8/14/2019 Operation Manual for SDH

    3/416

    4.1.1 Creating and Viewing Equipment Room Information 4-3.....................

    4.1.2 Creating and Viewing Cabinet Information 4-4....................................

    4.1.3 Modifying and Viewing Subrack Information 4-5..................................

    4.2 Viewing NE Resource 4-7............................................................................

    4.3 Uploading Data if NE has been Configured 4-8...........................................

    4.3.1 Uploading/ Downloading NE Configuration Data 4-8...........................

    4.3.2 Checking Configuration Data Consistency Between NE andthe T2000 4-9................................................................................................

    4.4 Duplicating NE Configuration Data 4-11.........................................................

    4.5 Manually Configuring NE Data 4-13...............................................................

    4.6 Creating Unit 4-14..........................................................................................

    4.7 Deleting Unit 4-15...........................................................................................

    4.8 Viewing Unit Version 4-16..............................................................................

    4.9 Creating and Viewing Physical Location Information 4-17.............................

    4.9.1 Creating and Viewing Equipment Room Information 4-17.....................

    4.9.2 Creating and Viewing Cabinet Information 4-18....................................

    4.9.3 Modifying and Viewing Subrack Information 4-19..................................

    4.10 Viewing NE Hardware Information 4-21.......................................................

    5 Configuring Communication 5-1.......................................................................

    5.1 Setting NE Communication Parameters 5-4.................................................

    5.2 Enabling Ethernet Port of an NE 5-5............................................................

    5.3 Setting DCC Rate and Allocating the Resource 5-6.....................................5.4 Setting DCC Transparent Transmission 5-7.................................................

    5.5 Changing an Ordinary NE into a GNE 5-8....................................................

    5.6 Modifying the Attributes of a GNE 5-9..........................................................

    5.7 Changing a GNE into an Ordinary NE 5-10....................................................

    5.8 Changing GNE for an NE 5-11.......................................................................

    5.9 Adding Standby GNEs for an NE 5...........................................................

    6 Configuring Protection 6-1.................................................................................

    6.1 Configuring 1+ 1 Unit Protection 6-2............................................................6.2 Configuring TPS Protection 6-3....................................................................

    6.3 Configuring MSP Protection 6-5...................................................................

    6.3.1 Creating Two-Fiber MS SPRing 6-5.....................................................

    6.3.2 Creating Two-Fiber MS DPRing 6-9....................................................

    6.3.3 Creating Four-Fiber MS SPRing 6-11....................................................

    6.3.4 Creating 1+ 1 Linear MSP 6-14.............................................................

    6.3.5 Creating M:N Linear MSP 6-17..............................................................

    6.4 Configuring SNCP Protection 6-20.................................................................

    6.5 Configuring PP Protection 6-22......................................................................

    6.5.1 Creating Diverse Route PP 6-22............................................................

  • 8/14/2019 Operation Manual for SDH

    4/416

    6.5.2 Creating Uniform Route PP 6-24...........................................................

    6.6 Configuring DNI Protection 6-26.....................................................................

    6.7 Configuring Non-Protection Ring 6-29............................................................

    6.8 Configuring Non-Protection Chain 6-32..........................................................

    6.9 Deleting Protection Subnet 6-35.....................................................................

    7 Configuring Service over Trail 7-1....................................................................

    7.1 Configuring SDH Service over Trail 7-2.......................................................

    7.1.1 Creating VC4 Trail 7-2.........................................................................

    7.1.2 Creating Common VC12/VC3 Trail 7-4................................................

    7.1.3 Creating SNCP VC12/VC3 Trail 7-5....................................................

    7.1.4 Viewing Trail 7-7..................................................................................

    7.1.5 Configuring Trace Byte over Trail 7-8..................................................

    7.1.6 Configuring C2 Byte over Trail 7-9.......................................................7.1.7 Setting Overhead Termination over Trail 7-11.......................................

    7.1.8 Deleting SDH Trail 7-12.........................................................................

    7.2 Configuring Ethernet Service over Trail 7-14.................................................

    7.2.1 Creating EPL Service 7-14.....................................................................

    7.2.2 Creating EVPL Service 7-19..................................................................

    7.2.3 Creating EPLn Service 7-26...................................................................

    7.2.4 Deleting Ethernet Trail 7-33...................................................................

    7.2.5 Deleting Trunk Link Trail 7-33................................................................

    8 Configuring Service at Single Station 8-1........................................................

    8.1 Configuring SDH Service at Single Station 8-2............................................

    8.1.1 Creating Common Service 8-2.............................................................

    8.1.2 Creating SNCP Service 8-3.................................................................

    8.1.3 Transfering SNCP Service to Common Service 8-6............................

    8.1.4 Transfering Common Service to SNCP Service 8-7............................

    8.2 Configuring ATM Service at Single Station 8-10............................................

    8.3 Configuring Ethernet Service at Single Station 8-17......................................

    8.3.1 Creating Transparently Transmitted Ethernet Service 8-17...................

    8.3.2 Creating Layer 2 Switching Ethernet Service 8-21................................

    8.3.3 Creating EPL Service 8-26.....................................................................

    8.3.4 Creating EVPL Service 8-30..................................................................

    8.3.5 Creating EPLn Service 8-33...................................................................

    8.3.6 Creating EVPLn Service 8-38................................................................

    9 Configuring Unit Parameters 9-1.......................................................................

    9.1 Configuring SDH Unit 9-3.............................................................................

    9.2 Configuring PDH Unit 9-5.............................................................................9.3 Configuring Ethernet Unit 9-8.......................................................................

  • 8/14/2019 Operation Manual for SDH

    5/416

    9.3.1 Configuring Internal Port 9-8................................................................

    9.3.2 Configuring External Port 9-10...............................................................

    9.3.3 Configuring Binding Path 9-12...............................................................

    9.4 Configuring ATM Unit 9-14.............................................................................

    9.4.1 Setting the VC4 Ports of ATM Board as SDH NNI 9-14.........................

    9.4.2 Installing the ATM Interface Board at NM Side 9-15..............................

    9.4.3 Configuring the Port Attributes 9-16.......................................................

    9.5 Configuring Optical Amplifier Unit 9-18..........................................................

    9.5.1 Configuring Optical Amplifier 9-18.........................................................

    9.5.2 Configuring Laser 9-19...........................................................................

    9.5.3 Configuring Path 9-20............................................................................

    9.5.4 Configuring Output Power 9-21..............................................................

    9.6 Configuring TDA Unit 9-23.............................................................................

    9.6.1 Configuring TDA Clock Source 9-23......................................................

    9.6.2 Configuring TDA Feeding Mode 9-23....................................................

    10 Configuring Clock 10-1.......................................................................................

    10.1 Setting Priority Table for Reference Clock 10-2...........................................

    10.2 Setting Switching Condition for Clock Source 10-4......................................

    10.3 Setting Restoration Parameters for Clock Source 10-5................................

    10.4 Switching Clock Source 10-6........................................................................

    10.5 Setting External Clock Source 10-8..............................................................

    10.6 Setting Phase-Locked Source 10-9..............................................................

    10.7 Setting Clock Subnet 10-10............................................................................

    10.7.1 Setting Clock Subnet Attributes 10-10...................................................

    10.7.2 Setting Clock Source Quality 10-11.......................................................

    10.7.3 Setting SSM Output 10-12.....................................................................

    10.8 Viewing Clock Synchronization Status 10-13.................................................

    11 Configuring Overhead Interface 11-1................................................................

    11.1 Configuring Orderwire Phone 11-2...............................................................

    11.2 Configuring Conference Call 11-3................................................................

    11.3 Configuring Auxiliary Port 11-5.....................................................................

    11.4 Configuring F1 Data Port 11-6......................................................................

    11.5 Configuring Broadcast Data Port 11-7..........................................................

    11.6 Configuring Data Port and Out-Ring Route 11-8..........................................

    11.7 Configuring Subnet No. for the Optical Interface 11-9..................................

    12 Configuring Alarm and Performance Monitoring Parameters 12-1................

    12.1 Setting Network Wide Alarm Attributes 12-3................................................

    12.1.1 Creating Alarm Attribute Template 12-3...............................................12.1.2 Creating Alarm Correlation Rules 12-4................................................

  • 8/14/2019 Operation Manual for SDH

    6/416

    12.1.3 Creating Fault Diagnosis Rule 12-4.....................................................

    12.1.4 Setting Alarm Function Switch 12-6.....................................................

    12.1.5 Enabling Alarm Notification to E-mail or Pager 12-7............................

    12.1.6 Enabling Alarm Box and Setting Parameter 12-9................................

    12.1.7 Setting Alarm Dump Condition 12-10.....................................................

    12.2 Setting NE Alarm Attributes 12-12..................................................................

    12.3 Setting Board/Port Alarm Attributes 12-14.....................................................

    12.3.1 Setting Alarm Severity and Auto-report 12-14.......................................

    12.3.2 Setting Alarm Suppression Status 12-15...............................................

    12.3.3 Setting Alarm Filter Status 12-16...........................................................

    12.3.4 Setting Bit Error Alarm Threshold 12-17................................................

    12.3.5 Setting AIS Insertion Switch 12-18.........................................................

    12.3.6 Setting UNEQ Insertion Switch 12-19....................................................

    12.4 Setting Trail Alarm Attributes 12-21................................................................

    12.4.1 Setting Trail Alarm Suppression 12-21..................................................

    12.4.2 Setting Trail Alarm Reversion 12-23......................................................

    12.5 Setting Performance Monitoring Parameters 12-25.......................................

    12.5.1 Creating Performance Threshold Template 12-25.................................

    12.5.2 Setting Board Performance Threshold 12-26.........................................

    12.5.3 Setting Trail Performance Parameters 12-27.........................................

    12.5.4 Resetting NE Performance Register 12-29............................................

    12.5.5 Resetting ATM Performance Register 12-30.........................................12.5.6 Resetting Ethernet Performance Register 12-31...................................

    12.5.7 Setting Performance Dump Conditions 12-32........................................

    12.6 Setting Performance Monitor 12-34................................................................

    12.6.1 Starting or Stopping Performance Monitoring 12-34..............................

    12.6.2 Setting Performance Monitoring Object 12-35.......................................

    12.6.3 Setting ATM Performance Monitor 12-36...............................................

    12.6.4 Setting Ethernet Performance Monitor 12-37.........................................

    12.6.5 Setting Non-Periodic Automatic Report of Performance Event 12-38...

    13 Synchronization and Data Management 13-1...................................................

    13.1 Synchronizing NE Time 13-3........................................................................

    13.2 Synchronizing Current Alarms from NE 13-4...............................................

    13.3 Backing up and Restoring T2000 Database 13-6.........................................

    13.3.1 Immediately Backing up T2000 Database 13-6...................................

    13.3.2 Enabling Automatical T2000 Database Backup 13-6...........................

    13.3.3 Restoring T2000 Database 13-8..........................................................

    13.3.4 Initializing T2000 Database 13-10..........................................................

    13.4 Managing NE Database 13-11.......................................................................13.4.1 Checking the Consistency of NE Configuration Data 13-11..................

  • 8/14/2019 Operation Manual for SDH

    7/416

    13.4.2 Uploading/Downloading NE Configuration Data 13-13..........................

    13.4.3 Duplicating NE Configuration Data 13-13..............................................

    13.4.4 Initializing NE Configuration Data 13-13................................................

    13.4.5 Exporting ROME Text Files Periodically 13-15......................................

    14 Routine Maintenance 14-1..................................................................................

    14.1 Browsing Alarm 14-2....................................................................................

    14.1.1 Synchronizing Current Alarms from NE 14-2.......................................

    14.1.2 Browsing Network-Wide Current Alarms for Selected Severity 14-2...

    14.1.3 Browsing Network-Wide Current Alarms for All Severities 14-3..........

    14.1.4 Browsing Current Alarms of an NE 14-4..............................................

    14.1.5 Browsing Current Alarms of Trails 14-4...............................................

    14.1.6 Browsing Current Alarms of Trunk Link Trails 14-6.............................

    14.1.7 Browsing Current Alarms of Ethernet Trails 14-7.................................14.1.8 Browsing Abnormal Events 14-9..........................................................

    14.1.9 Browsing Alarm Statistics and Output Report 14-10..............................

    14.1.10 Turning off Alarm Indicator on Alarm Box 14-11..................................

    14.1.11 Clearing Alarms 14-12.........................................................................

    14.2 Browsing Performance 14-13.........................................................................

    14.2.1 Browsing Current Performance Data 14-13...........................................

    14.2.2 Browsing History Performance Data 14-14............................................

    14.2.3 Browsing PM Threshold-crossing Record 14-16....................................

    14.2.4 Browsing Current Performance of Ethernet Port 14-17.........................

    14.2.5 Browsing History Performance of Ethernet Port 14-18..........................

    14.2.6 Browsing History Control Performance Data of Ethernet Port 14-18.....

    14.2.7 Browsing Performance Alarm Data of Ethernet Port 14-19...................

    14.2.8 Browsing Current Performance of ATM Port 14-20...............................

    14.2.9 Browsing History Performance of ATM Port 14-21................................

    14.3 Browsing Operation Log 14-23.......................................................................

    14.4 Checking Switching Status 14-25...................................................................

    14.4.1 Checking TPS Protection Switching 14-25............................................14.4.2 Checking 1+1 Board Switching 14-25....................................................

    14.4.3 Checking MSP Switching Status 14-26..................................................

    14.4.4 Checking SNCP/PP Switching Status 14-27..........................................

    14.4.5 Checking Network-wide MS Parameters 14-28.....................................

    14.4.6 Checking GNE Switching 14-29.............................................................

    14.4.7 Checking Clock Switching 14-30............................................................

    14.5 Managing Overhead Byte 14-32.....................................................................

    14.6 Synchronization 14-34....................................................................................

    14.7 Backing up and Restoring T2000 Database 14-34.........................................14.8 Equipment Data Collection 14-34...................................................................

  • 8/14/2019 Operation Manual for SDH

    8/416

    14.9 Automatic Disabling of NE Function 14-36.....................................................

    15 Fault Maintenance 15-1......................................................................................

    15.1 Loopback 15-2..............................................................................................

    15.1.1 Loopback at SDH Interface 15-2..........................................................15.1.2 Loopback at PDH Interface 15-4..........................................................

    15.1.3 Loopback at Ethernet Interface 15-5....................................................

    15.1.4 Loopback at VC4 Path 15-7.................................................................

    15.1.5 Loopback at VC3 Path 15-8.................................................................

    15.1.6 Loopback over Trail 15-10.....................................................................

    15.2 Fault Diagnosis Wizard 15-13........................................................................

    15.2.1 Set Fault Diagnosis Rules 15-13............................................................

    15.2.2 Fault Diagnosis Wizard 15-14................................................................

    15.3 Performing Protection Switching 15-16..........................................................15.3.1 Performing MSP Ring Switching 15-16..................................................

    15.3.2 Performing Linear MSP Switching 15-17...............................................

    15.3.3 Performing SNCP Ring Switching 15-19................................................

    15.3.4 Performing 1+1 Unit Protection Swtiching 15-20...................................

    15.3.5 Performing TPS Switching 15-21...........................................................

    15.4 Hard Resetting and Soft Resetting Unit 15-23...............................................

    15.5 Resetting NE Software 15-24.........................................................................

    15.6 Remote Maintenance 15-25...........................................................................

    15.7 2M Pseudo Number Test 15-27.....................................................................

    A Obtaining and Installing License A-1................................................................

    A.1 Obtaining the License A-1............................................................................

    A.2 Installing the License A-4.............................................................................

    B Abbreviations B-1...............................................................................................

  • 8/14/2019 Operation Manual for SDH

    9/416

    Huawei Technologies Proprietary

    HUAWEI

    OptiX iManager T2000

    Operation Manual for SDH

    V100R008

  • 8/14/2019 Operation Manual for SDH

    10/416

    Huawei Technologies Proprietary

    OptiX iManager T2000

    Operation Manual for SDH

    Manual Version T2-041662-20041118-C-1.82

    Product Version V100R008

    BOM 31161162

    Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service.Please feel free to contact our local office or company headquarters.

    Huawei Technologies Co., Ltd.Address: Administration Building, Huawei Technologies Co., Ltd.,

    Bantian, Longgang District, Shenzhen, P. R. China

    Postal Code: 518129

    Website: http://www.huawei.com

    Email: [email protected]

  • 8/14/2019 Operation Manual for SDH

    11/416

  • 8/14/2019 Operation Manual for SDH

    12/416

    Huawei Technologies Proprietary

    Summary of Updates

    This section provides the update history of this manual and introduces the contents of

    subsequent updates.Update History

    Manual Version Notes

    T2-041662-20040612-C-1.80 Initial field trial release

    T2-041662-20040914-C-1.81 Second time release

    T2-041662-20041118-C-1.82 Third time release.

    Updates of Contents

    Updates between document versions are cumulative. Therefore, the latest documentversion contains all updates made to previous versions.

    Updates in Manual Version 1.81

    Add several ROME interface files in 13.4.5.

    Updates in Manual Version 1.81

    Add 2.3.8 Deleting Fiber.

    Add 6.9 Deleting Protection Subnet.

    Add 7.1.8 Deleting SDH Trail.

    Add 7.2.4 Deleting Ethernet Trail.

    Add 7.2.5 Deleting Trunk Link Trail.

    Add 13.4.5 Exporting ROME Text Files Periodically.

    Add 14.1.6 Browsing Current Alarms of Trunk Link Trails.

    Add 14.1.7 Browsing Current Alarms of Ethernet Trails.

  • 8/14/2019 Operation Manual for SDH

    13/416

    OptiX iManager T2000

    Operation Manual for SDH Contents

    Huawei Technologies Proprietary

    i

    Contents

    1 Quick Start 1-11.1 Starting and Shutting down T2000 1-2

    1.1.1 Starting T2000 Computer 1-21.1.2 Shutting down T2000 Computer 1-41.1.3 Starting T2000 Server 1-51.1.4 Exiting T2000 Server from System Monitor 1-61.1.5 Exiting T2000 Server from T2000 Client 1-61.1.6 Restarting T2000 Server 1-71.1.7 Starting T2000 Client 1-81.1.8 Exiting T2000 Client 1-91.1.9 Switching T2000 User 1-10

    1.2 Verifying whether License File has been Installed Correctly 1-111.3 Opening Online Help 1-121.4 Closing Online Help 1-141.5 System Setting 1-15

    1.5.1 Enabling Display of Needed Functions 1-151.5.2 Setting Alarm Sounds 1-161.5.3 Setting View Background 1-171.5.4 Setting Screen Lockout 1-181.5.5 Changing NM Users Password 1-20

    1.6 Views 1-211.6.1 Main Topology 1-211.6.2 Equipment Maintenance Console 1-221.6.3 Protection View 1-231.6.4 Trail View 1-241.6.5 Clock View 1-251.6.6 DCN View 1-26

  • 8/14/2019 Operation Manual for SDH

    14/416

    OptiX iManager T2000

    Operation Manual for SDH Contents

    Huawei Technologies Proprietary

    ii

    1.6.7 Custom View 1-271.6.8 NE Panel 1-30

    1.7 Selecting Operation Objects from Object Tree 1-321.8 Setting Parameters in the List 1-33

    1.9 Operation Precautions 1-34

    2 Creating Topology 2-12.1 Creating NEs 2-2

    2.1.1 Searching NEs in Batch 2-22.1.2 Manually Creating NEs 2-32.1.3 Deleting NE 2-42.1.4 Switching NE User 2-52.1.5 Creating Topology Subnet 2-6

    2.2 Changing NE Attributes 2-8

    2.2.1 Changing NE Name and Remarks 2-82.2.2 Changing NE IP Address 2-92.2.3 Changing NE Extended ID 2-102.2.4 Changing NE Subnet Mask 2-112.2.5 Changing NE Pre-configuration Attribute 2-12

    2.3 Creating Links 2-132.3.1 Creating Fiber/Cable 2-132.3.2 Deleting Fiber 2-142.3.3 Creating NM Ethernet Line 2-162.3.4 Creating Extended ECC 2-162.3.5 Creating Serial Port Line 2-17

    2.4 Creating NM 2-193 Security Management 3-1

    3.1 Creating NE User and Assigning Authority 3-23.2 Managing NE Login 3-3

    3.2.1 Switching NE User 3-33.2.2 Forcing NE User to Log out NE 3-43.2.3 Locking NE Login 3-43.2.4 Locking NE Settings 3-53.2.5 Setting NE Security Parameters 3-63.2.6 Browsing NE Security Log 3-7

    3.3 Creating NM User 3-93.3.1 Adding Operation Set 3-9

  • 8/14/2019 Operation Manual for SDH

    15/416

    OptiX iManager T2000

    Operation Manual for SDH Contents

    Huawei Technologies Proprietary

    iii

    3.3.2 Adding Equipment Set 3-103.3.3 Adding NM User Group 3-113.3.4 Modifying Authority of NM User Group 3-113.3.5 Creating NM User and Assign Authority 3-13

    3.3.6 Slightly Adjusting Authority of NM User 3-143.3.7 Modifying General User Attribute 3-153.3.8 Enabling Remote Maintenance User 3-16

    3.4 Managing T2000 Login 3-173.4.1 Locking T2000 Client Screen 3-173.4.2 Switching NM User 3-173.4.3 Switching Between Single User Mode and Multi-user Mode 3-173.4.4 Forcing Other Users to Exit T2000 3-183.4.5 Modifying NM Users Password 3-19

    4 Configuring Equipment 4-14.1 Creating and Viewing Physical Location Information 4-2

    4.1.1 Creating and Viewing Equipment Room Information 4-24.1.2 Creating and Viewing Cabinet Information 4-34.1.3 Modifying and Viewing Subrack Information 4-4

    4.2 Viewing NE Resource 4-64.3 Uploading Data if NE has been Configured 4-7

    4.3.1 Uploading/Downloading NE Configuration Data 4-74.3.2 Checking Configuration Data Consistency Between NE and the T2000 4-8

    4.4 Duplicating NE Configuration Data 4-104.5 Manually Configuring NE Data 4-124.6 Creating Unit 4-134.7 Deleting Unit 4-144.8 Viewing Unit Version 4-154.9 Creating and Viewing Physical Location Information 4-16

    4.9.1 Creating and Viewing Equipment Room Information 4-16

    4.9.2 Creating and Viewing Cabinet Information 4-174.9.3 Modifying and Viewing Subrack Information 4-18

    4.10 Viewing NE Hardware Information 4-205 Configuring Communication 5-1

    5.1 Setting NE Communication Parameters 5-25.2 Enabling Ethernet Port of an NE 5-35.3 Setting DCC Rate and Allocating the Resource 5-4

  • 8/14/2019 Operation Manual for SDH

    16/416

    OptiX iManager T2000

    Operation Manual for SDH Contents

    Huawei Technologies Proprietary

    iv

    5.4 Setting DCC Transparent Transmission 5-55.5 Changing an Ordinary NE into a GNE 5-65.6 Modifying the Attributes of a GNE 5-75.7 Changing a GNE into an Ordinary NE 5-8

    5.8 Changing GNE for an NE 5-95.9 Adding Standby GNEs for an NE 5-10

    6 Configuring Protection 6-16.1 Configuring 1+1 Unit Protection 6-26.2 Configuring TPS Protection 6-36.3 Configuring MSP Protection 6-5

    6.3.1 Creating Two-Fiber MS SPRing 6-56.3.2 Creating Two-Fiber MS DPRing 6-9

    6.3.3 Creating Four-Fiber MS SPRing 6-116.3.4 Creating 1+1 Linear MSP 6-146.3.5 Creating M:N Linear MSP 6-17

    6.4 Configuring SNCP Protection 6-206.5 Configuring PP Protection 6-22

    6.5.1 Creating Diverse Route PP 6-226.5.2 Creating Uniform Route PP 6-24

    6.6 Configuring DNI Protection 6-266.7 Configuring Non-Protection Ring 6-296.8 Configuring Non-Protection Chain 6-326.9 Deleting Protection Subnet 6-35

    7 Configuring Service over Trail 7-17.1 Configuring SDH Service over Trail 7-2

    7.1.1 Creating VC4 Trail 7-27.1.2 Creating Common VC12/VC3 Trail 7-47.1.3 Creating SNCP VC12/VC3 Trail 7-57.1.4 Viewing Trail 7-77.1.5 Configuring Trace Byte over Trail 7-87.1.6 Configuring C2 Byte over Trail 7-97.1.7 Setting Overhead Termination over Trail 7-117.1.8 Deleting SDH Trail 7-12

    7.2 Configuring Ethernet Service over Trail 7-147.2.1 Creating EPL Service 7-147.2.2 Creating EVPL Service 7-19

  • 8/14/2019 Operation Manual for SDH

    17/416

    OptiX iManager T2000

    Operation Manual for SDH Contents

    Huawei Technologies Proprietary

    v

    7.2.3 Creating EPLn Service 7-267.2.4 Deleting Ethernet Trail 7-337.2.5 Deleting Trunk Link Trail 7-33

    8 Configuring Service at Single Station 8-18.1 Configuring SDH Service at Single Station 8-2

    8.1.1 Creating Common Service 8-28.1.2 Creating SNCP Service 8-38.1.3 Transfering SNCP Service to Common Service 8-68.1.4 Transfering Common Service to SNCP Service 8-7

    8.2 Configuring ATM Service at Single Station 8-108.3 Configuring Ethernet Service at Single Station 8-17

    8.3.1 Creating Transparently Transmitted Ethernet Service 8-17

    8.3.2 Creating Layer 2 Switching Ethernet Service 8-218.3.3 Creating EPL Service 8-268.3.4 Creating EVPL Service 8-308.3.5 Creating EPLn Service 8-338.3.6 Creating EVPLn Service 8-38

    9 Configuring Unit Parameters 9-19.1 Configuring SDH Unit 9-29.2 Configuring PDH Unit 9-4

    9.3 Configuring Ethernet Unit 9-7

    9.3.1 Configuring Internal Port 9-79.3.2 Configuring External Port 9-99.3.3 Configuring Binding Path 9-11

    9.4 Configuring ATM Unit 9-139.4.1 Setting the VC4 Ports of ATM Board as SDH NNI 9-139.4.2 Installing the ATM Interface Board at NM Side 9-149.4.3 Configuring the Port Attributes 9-15

    9.5 Configuring Optical Amplifier Unit 9-179.5.1 Configuring Optical Amplifier 9-179.5.2 Configuring Laser 9-189.5.3 Configuring Path 9-199.5.4 Configuring Output Power 9-20

    9.6 Configuring TDA Unit 9-229.6.1 Configuring TDA Clock Source 9-229.6.2 Configuring TDA Feeding Mode 9-22

  • 8/14/2019 Operation Manual for SDH

    18/416

    OptiX iManager T2000

    Operation Manual for SDH Contents

    Huawei Technologies Proprietary

    vi

    10 Configuring Clock 10-110.1 Setting Priority Table for Reference Clock 10-210.2 Setting Switching Condition for Clock Source 10-410.3 Setting Restoration Parameters for Clock Source 10-510.4 Switching Clock Source 10-610.5 Setting External Clock Source 10-810.6 Setting Phase-Locked Source 10-910.7 Setting Clock Subnet 10-10

    10.7.1 Setting Clock Subnet Attributes 10-1010.7.2 Setting Clock Source Quality 10-1110.7.3 Setting SSM Output 10-12

    10.8 Viewing Clock Synchronization Status 10-1311 Configuring Overhead Interface 11-1

    11.1 Configuring Orderwire Phone 11-211.2 Configuring Conference Call 11-311.3 Configuring Auxiliary Port 11-511.4 Configuring F1 Data Port 11-611.5 Configuring Broadcast Data Port 11-711.6 Configuring Data Port and Out-Ring Route 11-811.7 Configuring Subnet No. for the Optical Interface 11-9

    12 Configuring Alarm and Performance Monitoring Parameters 12-112.1 Setting Network Wide Alarm Attributes 12-2

    12.1.1 Creating Alarm Attribute Template 12-212.1.2 Creating Alarm Correlation Rules 12-312.1.3 Creating Fault Diagnosis Rule 12-312.1.4 Setting Alarm Function Switch 12-512.1.5 Enabling Alarm Notification to E-mail or Pager 12-612.1.6 Enabling Alarm Box and Setting Parameter 12-812.1.7 Setting Alarm Dump Condition 12-9

    12.2 Setting NE Alarm Attributes 12-1112.3 Setting Board/Port Alarm Attributes 12-13

    12.3.1 Setting Alarm Severity and Auto-report 12-1312.3.2 Setting Alarm Suppression Status 12-1412.3.3 Setting Alarm Filter Status 12-1512.3.4 Setting Bit Error Alarm Threshold 12-1612.3.5 Setting AIS Insertion Switch 12-17

  • 8/14/2019 Operation Manual for SDH

    19/416

    OptiX iManager T2000

    Operation Manual for SDH Contents

    Huawei Technologies Proprietary

    vii

    12.3.6 Setting UNEQ Insertion Switch 12-1812.4 Setting Trail Alarm Attributes 12-20

    12.4.1 Setting Trail Alarm Suppression 12-2012.4.2 Setting Trail Alarm Reversion 12-22

    12.5 Setting Performance Monitoring Parameters 12-24

    12.5.1 Creating Performance Threshold Template 12-2412.5.2 Setting Board Performance Threshold 12-2512.5.3 Setting Trail Performance Parameters 12-2612.5.4 Resetting NE Performance Register 12-2812.5.5 Resetting ATM Performance Register 12-2912.5.6 Resetting Ethernet Performance Register 12-3012.5.7 Setting Performance Dump Conditions 12-31

    12.6 Setting Performance Monitor 12-3312.6.1 Starting or Stopping Performance Monitoring 12-3312.6.2 Setting Performance Monitoring Object 12-3412.6.3 Setting ATM Performance Monitor 12-3512.6.4 Setting Ethernet Performance Monitor 12-3612.6.5 Setting Non-Periodic Automatic Report of Performance Event 12-37

    13 Synchronization and Data Management 13-113.1 Synchronizing NE Time 13-213.2 Synchronizing Current Alarms from NE 13-313.3 Backing up and Restoring T2000 Database 13-5

    13.3.1 Immediately Backing up T2000 Database 13-513.3.2 Enabling Automatical T2000 Database Backup 13-513.3.3 Restoring T2000 Database 13-713.3.4 Initializing T2000 Database 13-9

    13.4 Managing NE Database 13-1013.4.1 Checking the Consistency of NE Configuration Data 13-1013.4.2 Uploading/Downloading NE Configuration Data 13-12

    13.4.3 Duplicating NE Configuration Data 13-1213.4.4 Initializing NE Configuration Data 13-1213.4.5 Exporting ROME Text Files Periodically 13-14

    14 Routine Maintenance 14-114.1 Browsing Alarm 14-2

    14.1.1 Synchronizing Current Alarms from NE 14-214.1.2 Browsing Network-Wide Current Alarms for Selected Severity 14-2

  • 8/14/2019 Operation Manual for SDH

    20/416

    OptiX iManager T2000

    Operation Manual for SDH Contents

    Huawei Technologies Proprietary

    viii

    14.1.3 Browsing Network-Wide Current Alarms for All Severities 14-314.1.4 Browsing Current Alarms of an NE 14-414.1.5 Browsing Current Alarms of Trails 14-414.1.6 Browsing Current Alarms of Trunk Link Trails 14-6

    14.1.7 Browsing Current Alarms of Ethernet Trails 14-714.1.8 Browsing Abnormal Events 14-914.1.9 Browsing Alarm Statistics and Output Report 14-1014.1.10 Turning off Alarm Indicator on Alarm Box 14-1114.1.11 Clearing Alarms 14-12

    14.2 Browsing Performance 14-1314.2.1 Browsing Current Performance Data 14-1314.2.2 Browsing History Performance Data 14-1414.2.3 Browsing PM Threshold-crossing Record 14-1614.2.4 Browsing Current Performance of Ethernet Port 14-1714.2.5 Browsing History Performance of Ethernet Port 14-1814.2.6 Browsing History Control Performance Data of Ethernet Port 14-1814.2.7 Browsing Performance Alarm Data of Ethernet Port 14-1914.2.8 Browsing Current Performance of ATM Port 14-2014.2.9 Browsing History Performance of ATM Port 14-21

    14.3 Browsing Operation Log 14-2314.4 Checking Switching Status 14-25

    14.4.1 Checking TPS Protection Switching 14-2514.4.2 Checking 1+1 Board Switching 14-2514.4.3 Checking MSP Switching Status 14-2614.4.4 Checking SNCP/PP Switching Status 14-2714.4.5 Checking Network-wide MS Parameters 14-2814.4.6 Checking GNE Switching 14-2914.4.7 Checking Clock Switching 14-30

    14.5 Managing Overhead Byte 14-3214.6 Synchronization 14-3414.7 Backing up and Restoring T2000 Database 14-3414.8 Equipment Data Collection 14-3414.9 Automatic Disabling of NE Function 14-36

    15 Fault Maintenance 15-115.1 Loopback 15-2

    15.1.1 Loopback at SDH Interface 15-215.1.2 Loopback at PDH Interface 15-4

  • 8/14/2019 Operation Manual for SDH

    21/416

    OptiX iManager T2000

    Operation Manual for SDH Contents

    Huawei Technologies Proprietary

    ix

    15.1.3 Loopback at Ethernet Interface 15-515.1.4 Loopback at VC4 Path 15-715.1.5 Loopback at VC3 Path 15-815.1.6 Loopback over Trail 15-10

    15.2 Fault Diagnosis Wizard 15-13

    15.2.1 Set Fault Diagnosis Rules 15-1315.2.2 Fault Diagnosis Wizard 15-14

    15.3 Performing Protection Switching 15-1615.3.1 Performing MSP Ring Switching 15-1615.3.2 Performing Linear MSP Switching 15-1715.3.3 Performing SNCP Ring Switching 15-1915.3.4 Performing 1+1 Unit Protection Swtiching 15-2015.3.5 Performing TPS Switching 15-21

    15.4 Hard Resetting and Soft Resetting Unit 15-2315.5 Resetting NE Software 15-2415.6 Remote Maintenance 15-2515.7 2M Pseudo Number Test 15-27

    A Obtaining and Installing License A-1

    A.1 Obtaining the License A-1A.2 Installing the License A-4

    B Abbreviations B-1

  • 8/14/2019 Operation Manual for SDH

    22/416

    OptiX iManager T2000

    Operation Manual for SDH Figures

    Huawei Technologies Proprietary

    x

    Figures

    Figure 7-1Example of EPL application 7-14Figure 7-2Example of EVPL application 7-19Figure 7-3Example of EPLn application 7-26Figure 15-1Outloop at SDH optical interface 15-2Figure 15-2Inloop at SDH optical interface 15-2Figure 15-3Outloop at PDH interface 15-4Figure 15-4Inloop at PDH interface 15-4Figure 15-5Outloop at Ethernet interface 15-6Figure 15-6Inloop at Ethernet interface 15-6Figure 15-7Outloop over VC4 path 15-7Figure 15-8Inloop over VC4 path 15-7Figure 15-9Outloop over VC3 Path 15-9Figure 15-10Inloop over VC3 Path 15-9Figure 15-11Loopback to Source over trail 15-10Figure 15-12Loopback to Sink over Trail 15-11Figure 15-13RAS-based remote maintenance 15-25

  • 8/14/2019 Operation Manual for SDH

    23/416

    OptiX iManager T2000

    Operation Manual for SDH Tables

    Huawei Technologies Proprietary

    xi

    Tables

    Table 13-1Files and usage 13-14

  • 8/14/2019 Operation Manual for SDH

    24/416

    OptiX iManager T2000

    Operation Manual for SDH About this Manual

    Huawei Technologies Proprietary

    i

    About this Manual

    Related Manuals

    Manual Usage

    OptiX iManager T2000 System

    Description

    Introduces the position, functional characteristics, system

    architecture and networking mode of the T2000, appended withstandards that the T2000 complies with, abbreviations andperformance indices.

    OptiX iManager T2000 InstallationManual

    Introduces the installation procedure and FAQ of T2000 underthe platforms of Windows2000 and Solaris 8.

    OptiX iManager T2000 OperationManual for SDH

    Introduces the configuration and maintenance operations ofSDH equipment in the T2000.

    OptiX iManager T2000 OperationManual for WDM

    Introduces the configuration and maintenance operations ofWDM equipment in the T2000.

    OptiX iManager T2000 ElectronicDocumentation for SDH&WDM

    Contains all the above manuals in CD-ROM format, readablewith Acrobat Reader.

    Organization

    The manual has the following organization:

    Chapter Description

    Chapter 1 Quick Start This chapter introduces some preparationoperations that make the T2000 into a fine workstatus.

    Chapter 2 CreatingTopology

    This chapter introduces how to create topologyobjects in the T2000.

    Chapter 3 SecurityManagement

    This chapter introduces some security managementtasks of the T2000.

    Chapter 4 ConfiguringEquipment

    This chapter introduces how to configure equipmentin the T2000.

    Chapter 5 ConfiguringCommunication

    This chapter introduces basic communicationconfiguring operations that ensures normalcommunication between the NEs and the T2000.

  • 8/14/2019 Operation Manual for SDH

    25/416

    OptiX iManager T2000

    Operation Manual for SDH About this Manual

    Huawei Technologies Proprietary

    ii

    Chapter Description

    Chapter 6 ConfiguringProtection

    This chapter introduces how to provisionequipment-level protection and network-levelprotection.

    Chapter 7 ConfiguringService over Trail

    This chapter introduces how to configure SDHservice and Ethernet service over trail.

    Chapter 8 ConfiguringService at SingleStation

    This chapter introduces how to configure SDHservice, ATM service and Ethernet service at singlestation.

    Chapter 9 ConfiguringUnit Parameters

    This chapter introduces how to configure units.

    Chapter 10 ConfiguringClock

    This chapter introduces how to configure clock forSDH equipment.

    Chapter 11 ConfiguringOverhead Interface

    This chapter introduces how to configure theoverhead interfaces of SDH equipment.

    Chapter 12 ConfiguringAlarm and PerformanceMonitoring Parameters

    This chapter introduces how to configuring alarmand performance monitoring parameters.

    Chapter 13Synchronization andData Management

    This chapter introduces the operations ofsynchronization and data management.

    Chapter 14 RoutineMaintenance

    This chapter includes the tasks in the routinemaintenance work, which should be done regularly,

    may be daily, weekly or monthly.

    Chapter 15 FaultMaintenance

    This chapter introduces basic operations of faultmaintenance.

    Appendix A: This part introduces how to obtain and install thelicense.

    B: Abbreviations

    Intended Audience

    This manual is for:

    Transmission network management system operator

    Conventions

    The manual uses the following conventions.

    Symbol Conventions

    Symbol Description

    Warning

    A warning notice with this symbol indicate a potentially hazardoussituation in which there is a possibility of personal injury.

  • 8/14/2019 Operation Manual for SDH

    26/416

    OptiX iManager T2000

    Operation Manual for SDH About this Manual

    Huawei Technologies Proprietary

    iii

    Symbol Description

    Caution

    A caution notice with this symbol indicates a risk to equipmentdamage or loss of data.

    ImportantNote: An important note notice with this symbol helps you avoid anundesirable situation or indicates important supplementary

    information.

    Note: A note notice with this symbol indicates additional, helpful,non-critical information.

    GUI Conventions

    Convention Description

    < > Button name are inside angle brackets. For example, click the

    button

    [ ] Window names, menu items, data table and field names are insidesquare brackets. For example, pop up the [New User] window.

    / Multi-level menus are separated by forward slashes. For example,[File/Create/Folder].

    Keyboard Operation

    Format Description

    Press the key with the key name inside angle brackets. For example,, , , or .

    Press the keys concurrently. For example, means thethree keys should be pressed concurrently.

    Press the keys in turn. For example, means the two keysshould be pressed in turn.

    Mouse Operation

    Action Description

    Select Press and hold the primary mouse button (left mouse button by default).

    Click Select and release the primary mouse button without moving the pointer.

    Double-click Press the primary mouse button twice continuously and quickly withoutmoving the pointer.

    Drag Press and hold the primary mouse button and move the pointer to a certainposition.

  • 8/14/2019 Operation Manual for SDH

    27/416

    OptiX iManager T2000

    Operation Manual for SDH 1 Quick Start

    Huawei Technologies Proprietary

    1-1

    1 Quick StartThis chapter introduces some preparation operations that make the T2000 into a finework status. The following tasks are described:

    Starting and Shutting down T2000

    Verifying whether License File has been Installed Correctly

    Opening Online Help

    Closing Online Help

    System Setting

    Views

    Selecting Operation Objects from Object Tree

    Setting Parameters in the List

    Operation Precautions

  • 8/14/2019 Operation Manual for SDH

    28/416

    OptiX iManager T2000

    Operation Manual for SDH 1 Quick Start

    Huawei Technologies Proprietary

    1-2

    1.1 Starting and Shutting down T2000

    1.1.1 Starting T2000 Computer

    Purpose

    Use this procedure to start the computer of UNIX platform and Windows platformcorrectly.

    The Sun workstation is different from personal computer (PC). Please start it bystrictly observing the following procedure to avoid the possible equipment damage ordata loss.

    Note:

    T2000 supports both UNIX platform and Windows platform and provides the samefunctions under the two platforms. For the system hardware details, refer to theOptiX iManager T2000 System Description.

    Prerequisites

    The T2000 hardware has been installed completely.

    Before starting the system, check the connections of the workstation powercable, monitor power cable, and monitor data cable. Check whether theEthernet cable of the workstation is correctly connected.

    If there is external equipment such as printer or modem, check whether theprinter or modem is correctly connected to the parallel interface or the serialinterface of the workstation respectively. Also, check the connection of thepower cable of such external equipment.

    Procedure

    1. On the UNIX platform

    Step Action

    1 Turn on the power switch of the external equipment, such as themonitor, modem, or printer.

    2 Turn on the power switch of the workstation host. The Solaris bootsautomatically to display the Common Desktop Environment (CDE) forlogin.

  • 8/14/2019 Operation Manual for SDH

    29/416

    OptiX iManager T2000

    Operation Manual for SDH 1 Quick Start

    Huawei Technologies Proprietary

    1-3

    Step Action

    3 Enter the user name and password in the login dialog box. Forexample:

    User: t2000 (the default is t2000)

    Password: t2000 (the default is t2000)

    4 The CDE starts completely.

    2. On the Windows platform

    Step Action

    1 Turn on the power switch of the external equipment, such as themonitor, modem, or printer.

    2 Turn on the power switch of the PC, and the MS Windows 2000 bootsautomatically for login.

    3 Enter the user name and password in the login dialog box. Forexample:

    User: t2000 (the default is t2000)

    Password: t2000 (the default is t2000)

    4 The MS Windows 2000 starts completely.

  • 8/14/2019 Operation Manual for SDH

    30/416

    OptiX iManager T2000

    Operation Manual for SDH 1 Quick Start

    Huawei Technologies Proprietary

    1-4

    1.1.2 Shutting down T2000 Computer

    Purpose

    Use this procedure to shut down the computer of T2000 server or T2000 clientcorrectly.

    The Sun workstation is different from PC. Please shut it down by strictly observingthe following procedure to avoid the possible equipment damage or data loss.

    Prerequisite

    Exit all running applications, including T2000 server, Sybase database, T2000client and so on.

    Procedure

    1. On the UNIX platform

    Step Action

    1 Open a terminal window and enter the following commands:

    %su rootPassword: rootkit#sync;sync;sync;sync;sync#shutdown -y -g0 -i5

    Note:1) The "rootkit" above is the default password of super user root. If the

    password is already changed, enter the new password.

    2) To reboot the Sun workstation, the last command is #shutdown -y -g0

    i6.

    2 The Sun workstation will be shut down automatically.

    3 Turn off the monitor and the external equipment.

    2. On the Windows platform

    Step Action

    1 Select the [Start/Shut down] from the Windows 2000 desktop.

    2 Select Shut down and click in the dialog box.

    3 The computer will be shut down automatically.

    4 Turn off the monitor and the external equipment.

  • 8/14/2019 Operation Manual for SDH

    31/416

    OptiX iManager T2000

    Operation Manual for SDH 1 Quick Start

    Huawei Technologies Proprietary

    1-5

    1.1.3 Starting T2000 Server

    Purpose

    Use this procedure to start the T2000 server at the first time.

    Prerequisites

    The T2000 server computer has been started correctly.

    The T2000 license file is placed in the server directory.

    Procedure

    Step Action

    1 Double-click the "T2000Server" icon on the desktop of the T2000server. The System Monitor login dialog box will be displayed in a fewseconds.

    2 Enter password and server in the login dialog box. For example,

    Password: T2000 (the default is T2000)

    Server: Local

    3 Wait a few minutes until the EMS server, Security server and Toposerver are all in Running status. If they are, it means the T2000

    server is started successfully.

  • 8/14/2019 Operation Manual for SDH

    32/416

    OptiX iManager T2000

    Operation Manual for SDH 1 Quick Start

    Huawei Technologies Proprietary

    1-6

    1.1.4 Exiting T2000 Server from System Monitor

    Purpose

    Use this procedure to shut down the T2000 server from the System Monitor.

    Prerequisite

    None

    Procedure

    Step Action

    1 Start and log in to the System Monitor.

    2 Select [System/Stop Server] in the System Monitor.

    3 A confirmation dialog box is displayed. Click .

    Wait for a moment until the EMS server, Security server and Toposerver are all in Stopped status. If they are, it means the T2000server is shut down successfully.

    1.1.5 Exiting T2000 Server from T2000 Client

    Purpose

    Use this procedure to shut down the T2000 server from the T2000 client.

    Prerequisite

    NM user with authority of "system administrator" or above.

    Procedure

    Step Action

    1 Start a T2000 client and log in the T2000.

  • 8/14/2019 Operation Manual for SDH

    33/416

    OptiX iManager T2000

    Operation Manual for SDH 1 Quick Start

    Huawei Technologies Proprietary

    1-7

    Step Action

    2 Select the [System/Shut Down Server] from the main menu.

    3 A confirmation dialog box is displayed. Click .

    Then the T2000 server and all the clients connected with this serverwill be shut down.

    1.1.6 Restarting T2000 Server

    Purpose

    The procedure for restarting T2000 server is different from the one specified in 1.1.3Starting T2000 Server at the first time, since the System Monitor server has beenstarted.

    Prerequisites

    The T2000 server has been shut down correctly.

    Procedure

    Step Action

    1 Run the System Monitor client program.

    Note:

    Usually, the System Monitor client program is

    C:\T2000\smclient\sysmonitor.bat on the Windows platform, and it is

    /T2000/smclient/sysmonitor.sh on the UNIX platform.

  • 8/14/2019 Operation Manual for SDH

    34/416

    OptiX iManager T2000

    Operation Manual for SDH 1 Quick Start

    Huawei Technologies Proprietary

    1-8

    Step Action

    2 Enter password and server in the login dialog box. For example,

    Password: T2000 (the default is T2000)

    Server: Local

    3 Select [System/Start Server] in the System Monitor.

    1.1.7 Starting T2000 Client

    Purpose

    Use this procedure to start the T2000 client correctly.

    Prerequisite

    The T2000 server has been started correctly.Procedure

    Step Action

    1 On the computer of T2000 client, double-click the T2000Clienticon on the desktop.

  • 8/14/2019 Operation Manual for SDH

    35/416

    OptiX iManager T2000

    Operation Manual for SDH 1 Quick Start

    Huawei Technologies Proprietary

    1-9

    Step Action

    2 Enter the user name, the password and the address of T2000server in the login dialog box. For example:

    Name: Admin

    Password: T2000

    Server: 129.9.0.254

    Note:

    1) By default, the initial user name of T2000 is admin, and the

    password is T2000. To ensure the security of the T2000, the

    administrator should instantly change this password and keep the new

    one.

    2) The administrator should create new T2000 users and assign them

    with certain authorities to NM staff.

    3 Click to enter the main topology windows of T2000.

    1.1.8 Exiting T2000 Client

    Purpose

    Use this procedure to exit the T2000 client only.

    Prerequisite

    None

    Procedure

    Step Action

    1 Select the [System/Exit] from the main menu.

    A confirmation dialog box is displayed.

    2 Click .

  • 8/14/2019 Operation Manual for SDH

    36/416

  • 8/14/2019 Operation Manual for SDH

    37/416

    OptiX iManager T2000

    Operation Manual for SDH 1 Quick Start

    Huawei Technologies Proprietary

    1-11

    1.2 Verifying whether License File has been Installed Correctly

    Purpose

    The functions of the T2000 are controlled by the license file. Without a license file,the T2000 can be started, but the features and management capability are limited.So, before starting the T2000, please make sure the license file has been correctlyinstalled.

    Prerequisites

    The T2000 license file is placed in the sub-directory server of T2000installation directory.

    The T2000 server has been started correctly.

    Procedure

    Step Action

    1 Start a T2000 client.

    2 Select [Help/About] from the Main Menu.

    3 Click .

    4 Check the functions and management capabilities listed in it.

    Note:

    1) If the functions are correct, the license works normally.

    2) If not, please exit the T2000 client and server first, and then reinstall

    the license file. The detailed information about how to install license file

    is described in the Appendix A.2 Installing License File or the OptiX

    iManager T2000 Installation Manual.

  • 8/14/2019 Operation Manual for SDH

    38/416

    OptiX iManager T2000

    Operation Manual for SDH 1 Quick Start

    Huawei Technologies Proprietary

    1-12

    1.3 Opening Online Help

    Purpose

    Help is the main information resources of the T2000, which can help you to masterthe operation procedures and know about the interface operation guides at any time.

    You can open the T2000 help in the following two ways:

    From the menu of the T2000 client

    From a certain function interface

    Prerequisite

    The T2000 has been working normally.

    Procedure

    Step Action

    1 Select [Help/Help Topics] from the Main Menu to display the helpwindow.

  • 8/14/2019 Operation Manual for SDH

    39/416

    OptiX iManager T2000

    Operation Manual for SDH 1 Quick Start

    Huawei Technologies Proprietary

    1-13

    Step Action

    2 In the operation interface of the T2000 client, press to displaythe help topic for this function.

    For example, press F1 in the SDH Interface functional window andthe Help Topic of this function is displayed.

  • 8/14/2019 Operation Manual for SDH

    40/416

    OptiX iManager T2000

    Operation Manual for SDH 1 Quick Start

    Huawei Technologies Proprietary

    1-14

    1.4 Closing Online Help

    Purpose

    Use this procedure to close the T2000 help window.

    Prerequisite

    None

    Procedure

    Step Action

    1 Make sure that the active dialog box has been closed, because it

    will lock the help window.

    2 Make sure that the pop-up help window has been closed beforeclosing the help window.

    Note:

    To close the pop-up window, click outside it in the help window.

    3 Click of the help windows to close it.

  • 8/14/2019 Operation Manual for SDH

    41/416

    OptiX iManager T2000

    Operation Manual for SDH 1 Quick Start

    Huawei Technologies Proprietary

    1-15

    1.5 System Setting

    1.5.1 Enabling Display of Needed Functions

    Purpose

    The T2000 can manage Huawei's optical transmission equipment, including theSONET equipment, DWDM equipment and SDH equipment. It can also manage theATM service and Ethernet service. You can set whether to display them at the clientas required.

    Furthermore, the T2000 hides some functions that are not used frequently asadvanced menus. You can set whether to display them at the client.

    Prerequisite

    NM user with the authority of "system operator" or above.

    Procedure

    Step Action

    1 Select [System/System Setting] from the Main Menu.

    2 Click the tab "Customize Function".

    3 Select the checkbox of SDH Functions, DWDM Functions, ATMFunctions and Ethernet Functions. In this way, only related menu

    items are displayed.

  • 8/14/2019 Operation Manual for SDH

    42/416

    OptiX iManager T2000

    Operation Manual for SDH 1 Quick Start

    Huawei Technologies Proprietary

    1-16

    Step Action

    4 If the less common functions need to be displayed in the menu,select the Show Advanced Menu checkbox.

    If not, skip this step.

    5 Click .

    6 Restart the client to validate the settings.

    1.5.2 Setting Alarm Sounds

    Purpose

    Use this procedure to set the prompt sounds of the system for reporting different

    severities of alarms as well as the sounds for exception events and performancethreshold-crossing events.

    Prerequisites

    NM user with the authority of "system operator" or above.

    The client must have installed the sound playing equipment.

    Procedure

    Step Action

    1 Select [System/System Setting] from the Main Menu.

    2 Click the tab "Sound".

    3 Set the voice type and duration of the event. Click to testthe alarm sound settings.

  • 8/14/2019 Operation Manual for SDH

    43/416

    OptiX iManager T2000

    Operation Manual for SDH 1 Quick Start

    Huawei Technologies Proprietary

    1-17

    Step Action

    4 If the alarm sound needs to be shut off forever on the T2000client, select the Shut off Sound Forever checkbox.

    If not, skip this step.

    5 Click .

    1.5.3 Setting View Background

    Purpose

    Use this procedure to set the backgrounds of the T2000 views respectively. You canselect the pictures provided by the T2000 or introduce other pictures.

    Prerequisite

    NM user with the authority of "system operator" or above.

    Procedure

    Step Action

    1 Select [System/System Setting] from the Main Menu and click thetab "Set Background".

    Or, right-click the view and select [background Settings].

    2 If the background pictures need to added or deleted on the T2000client, please click or .

    If not, skip this step.

  • 8/14/2019 Operation Manual for SDH

    44/416

  • 8/14/2019 Operation Manual for SDH

    45/416

    OptiX iManager T2000

    Operation Manual for SDH 1 Quick Start

    Huawei Technologies Proprietary

    1-19

    Step Action

    3 Enter the delay time in the Minute(s) entry box for lockingscreen.

    4 Click .

    Note:

    1) To lock the current client immediately, select [System/Lock NM

    Screen] in the Main Menu.

    2) To unlock the screen, press ++ and enter the

    login user password.

  • 8/14/2019 Operation Manual for SDH

    46/416

    OptiX iManager T2000

    Operation Manual for SDH 1 Quick Start

    Huawei Technologies Proprietary

    1-20

    1.5.5 Changing NM Users Password

    Purpose

    Use this procedure to change the current T2000 user's password.

    Prerequisite

    None

    Procedure

    Step Action

    1 Select [System/Change Password] from the Main Menu.

    2 Enter the old password.

    Enter the new password and confirm it.

    3 Click .

  • 8/14/2019 Operation Manual for SDH

    47/416

  • 8/14/2019 Operation Manual for SDH

    48/416

    OptiX iManager T2000

    Operation Manual for SDH 1 Quick Start

    Huawei Technologies Proprietary

    1-22

    1.6.2 Equipment Maintenance Console

    The equipment maintenance console is the main operation interface of the T2000.You can open the functions of equipment configuration, management and

    maintenance through selecting the corresponding function node in the navigationtree.

    Interface

    Navigation tree Toolbar

    Commond

    button

    Toolbar button

    Function Display boxList title

    Time/Date

    button

    Double-right-arrow

    button

    Object

    tree

    Parameter setting area

    Subnet/NE/Unit/

    Module name

    Combo

    box

    Refresh/Expand all/Collapse all

  • 8/14/2019 Operation Manual for SDH

    49/416

    OptiX iManager T2000

    Operation Manual for SDH 1 Quick Start

    Huawei Technologies Proprietary

    1-23

    1.6.3 Protection View

    The protection view enables search, browse, creation, setting and management onthe protection subnetwork as well as management on independent nodes and SDH

    NNI.

    Interface

  • 8/14/2019 Operation Manual for SDH

    50/416

    OptiX iManager T2000

    Operation Manual for SDH 1 Quick Start

    Huawei Technologies Proprietary

    1-24

    1.6.4 Trail View

    The trail view enables search, creation, configuration and maintenance managementfunctions on network trails.

    Interface

  • 8/14/2019 Operation Manual for SDH

    51/416

    OptiX iManager T2000

    Operation Manual for SDH 1 Quick Start

    Huawei Technologies Proprietary

    1-25

    1.6.5 Clock View

    The clock view provides a visible platform to enable NE clock setting, global clocksynchronization status query, and clock tracing and search functions.

    Interface

  • 8/14/2019 Operation Manual for SDH

    52/416

  • 8/14/2019 Operation Manual for SDH

    53/416

    OptiX iManager T2000

    Operation Manual for SDH 1 Quick Start

    Huawei Technologies Proprietary

    1-27

    1.6.7 Custom View

    A custom view is a topological view similar a Main Topology. Generally, in the T2000,different users have different network management ranges. A user can customize a

    view for the network topology and equipment under certain administration as aworking interface. In a custom view window, the topology structure of a network,including the link and subnet/NE, is displayed.

    Interface

    Topology

    view

    Toolbar

    T2000

    Server IP

    Main menuCustom view

    name

    Maintenance

    status

    Toolbar button

    Current

    T2000 userMulti-user/Single

    user mode

    Current

    topology subnet

    Shortcut menu

    Data & Time

    Alarm button

    Filter tab

    Legend tab

    Abnormal

    event indicator

  • 8/14/2019 Operation Manual for SDH

    54/416

    OptiX iManager T2000

    Operation Manual for SDH 1 Quick Start

    Huawei Technologies Proprietary

    1-28

    Procedure

    1. Create a custom view

    Step Action

    1 Select [View/Custom View] from the Main Menu.

    2 Click in the "View Management" dialog box.

    3 In the "Basic Attributes" tab, enter the view name and descriptionsand select the background.

    4 Click the "Object Selection" tab and select the link and subnet/NEto be included in the view.

    5 Click to create a custom view.

    2. Open a custom view

    Step Action

    1 Select [View/Custom View] from the Main Menu.

    2 Select a custom view record in the "View Management" dialogbox.

  • 8/14/2019 Operation Manual for SDH

    55/416

  • 8/14/2019 Operation Manual for SDH

    56/416

    OptiX iManager T2000

    Operation Manual for SDH 1 Quick Start

    Huawei Technologies Proprietary

    1-30

    1.6.8 NE Panel

    The NE panel displays the visual graphic objects of physical entities such assubracks, units, and ports. The graphic objects that constitute the NE panel reflect

    the status changes in different colors. In the T2000, the NE panel is the major meansof equipment configuration. It is also an important means for monitoring equipmentoperation status and locating fault.

    Interface

    Double-click the NE icon in the Main Topology view to display the NE panel.

    Right-click an idle slot, and select the unit to be added.

    CloseNE panel

    NE name and status Minimize

    Legend

    button

    Shortcut menu

    on an idle slot

    SlotStatus

    Unit

    Right-click a unit installed to display the corresponding shortcut menu. For example,right-click an OC48 and select [Path View] to display the detailed path information.

  • 8/14/2019 Operation Manual for SDH

    57/416

    OptiX iManager T2000

    Operation Manual for SDH 1 Quick Start

    Huawei Technologies Proprietary

    1-31

    CloseNE panel

    NE name and status Minimize

    Legend

    button

    Shortcut menu

    on a unit

    Slot

    Status

    Unit

    Path view

    Path

  • 8/14/2019 Operation Manual for SDH

    58/416

    OptiX iManager T2000

    Operation Manual for SDH 1 Quick Start

    Huawei Technologies Proprietary

    1-32

    1.7 Selecting Operation Objects from Object Tree

    Purpose

    Before any operations such as configuration and query in the EquipmentMaintenance Console, you need to select operation objects such as NE, unit, port orfunctional module from the object tree in the lower-left pane.

    The operations in the Equipment Maintenance Console are taken as an example inthe following description.

    Prerequisite

    None

    Procedure

    Step Action

    1 After any function selection in the equipment maintenanceconsole, the operation object concerning this function will beshown in the navigation tree on the lower left part of the view.

    2 Clicking before the operation object can extend the lowerdirectory contained.

    3 Clicking the check boxes before the operation objects can selector not select the objects and all the operation objects they contain.The object selected will have a before.

    4 Click double-right-arrow button (red) to be added to the operationinterface in the right pane. Then, operations such as query andconfiguration can be done there.

  • 8/14/2019 Operation Manual for SDH

    59/416

    OptiX iManager T2000

    Operation Manual for SDH 1 Quick Start

    Huawei Technologies Proprietary

    1-33

    1.8 Setting Parameters in the List

    Purpose

    The T2000 operation interface adopts the style of tree on the left and list on theright. All parameters are set in the list.

    The operations in the Equipment Maintenance Console are taken as an example inthe following description.

    Prerequisite

    None

    Procedure

    Step Action

    1 In the upper-left pane, select a functional node from theEquipment Maintenance Console navigation tree.

    2 In the lower-left pane, select the operation object from the objecttree and click the double-right-arrow button (red).

    3 Select one or more rows to be set in the list box.

    4 Double-click the column to be set in the list to display thepull-down combo box or edit box. Select the appropriate item fromthe combo box or type a desired value in the edit box.

    Another way is to right-click the item to be modified to select theappropriate item from the shortcut menu.

    5 Click .

  • 8/14/2019 Operation Manual for SDH

    60/416

    OptiX iManager T2000

    Operation Manual for SDH 1 Quick Start

    Huawei Technologies Proprietary

    1-34

    1.9 Operation Precautions

    It is forbidden to modify the system time of the server during the T2000operation. Please set the system time during the T2000 installation. To modifythe system time of the server, do exit from the T2000 server first and thenrestart it after the modification.

    Do not modify the name and IP address of the computer as T2000 serverrandomly.

    Log in the Solaris CDE as t2000 on the UNIX platform. While on the Windowsplatform, you must use the user name and password in the T2000 installationfor login.

    Make sure the data at NE side is consistent with that at the NM side. When theNE data configuration is finished and runs normally, please update the data atthe NM side manually or with auto synchronization function.

    Backup the T2000 database periodically to minimize the loss caused bysystem abnormity.

    If the login user has the authority of system administrator, the operation ofShut Down Server can be implemented. Be cautious to execute thisoperation to avoid shutting down the running server by mistake.

    It is recommended to query the latest data from the NE side before settingsparameters.

    Usually, when a dangerous operation is going to be implemented, the T2000will give a confirmation message to remind the operator.

  • 8/14/2019 Operation Manual for SDH

    61/416

    OptiX iManager T2000

    Operation Manual for SDH 2 Creating Topology

    Huawei Technologies Proprietary

    2-1

    2 Creating TopologyThis chapter introduces how to create topology objects in the T2000. This is the firststep in configuration.

    The following tasks are described:

    Creating NEs

    Changing NE Attributes

    Creating Links

    Creating NM

  • 8/14/2019 Operation Manual for SDH

    62/416

    OptiX iManager T2000

    Operation Manual for SDH 2 Creating Topology

    Huawei Technologies Proprietary

    2-2

    2.1 Creating NEs

    There are several ways to create NE icons.

    2.1.1 Searching NEs in Batch

    Purpose

    It is to search for the NE ID information of all NEs in a network and the IP addressesof the gateway NEs by specifying the IP address range of a network to be searched.

    Based on the above information, you can create NEs in batch on the T2000 anddisplay them on the Main Topology. The equipment search function of the T2000 canalso be used to search for and display the information about connection betweenNEs, but you need to manually create these fibers/cables one by one.

    Searching for and creating NEs in batch is quicker and more accurate than manuallycreating NEs one by one. This method applies to the situation that data has beenconfigured on the NE side and fiber/cable connection has been established betweenNEs.

    Prerequisite

    NM user with the authority of "system maintainer" or above.

    Procedure

    Step Action1 Select [Topology/Automatic Equipment Detection] from the Main

    Menu.

    2 Click . The Input IP dialog box is displayed.

    3 Set Address Type to IP Network Section the GNE Is in or GNEIP Address, and enter the IP address. Click .

    Note:

    You can repeat steps 2~3 to add multiple search fields. The default

    search field provided can be deleted.

    4 Click . The NEs and Links found are displayed aftersearch.

    5 Select the uncreated NE in the NEs Found list and click . The Current NE ID is dialog box is displayed.

  • 8/14/2019 Operation Manual for SDH

    63/416

    OptiX iManager T2000

    Operation Manual for SDH 2 Creating Topology

    Huawei Technologies Proprietary

    2-3

    Step Action

    6 Enter the NE user name and password. You can select the All NEsuse the same User and Password or Save User and Password forRe-Use combo box when creating multiple NEs.

    7 Click . The NE is created in the Main Topology.

    2.1.2 Manually Creating NEs

    Purpose

    Use this procedure to manually create NEs one by one.

    This method applies to the situation no matter whether data has been configured onthe NE side or not.

    Prerequisite

    NM user with the authority of "system maintainer" or above.

    Procedure

    Step Action

    1 Right-click in the Main Topology and select [Create/TopologyObject].

  • 8/14/2019 Operation Manual for SDH

    64/416

    OptiX iManager T2000

    Operation Manual for SDH 2 Creating Topology

    Huawei Technologies Proprietary

    2-4

    Step Action

    2 Select the NE type from the Create Topology Object dialog boxand enter the attribute information of the NE.

    Note:

    Default NE user of the T2000: root; default password: password. The

    NE user to create an NE is at the system maintainer level at least.

    You can choose the Pre-Configuration combo box if the data has not

    been configured on the NE side.

    3 Click .

    4 Click in the Main Topology. The icon of this NE appears in theposition where you click.

    2.1.3 Deleting NE

    Purpose

    Use this procedure to manually delete NEs one by one on the NM side.

    Prerequisites

    NM user with the authority of "system maintainer" or above.

    Fibers and cables connected to the NE have been deleted.

  • 8/14/2019 Operation Manual for SDH

    65/416

    OptiX iManager T2000

    Operation Manual for SDH 2 Creating Topology

    Huawei Technologies Proprietary

    2-5

    Procedure

    Step Action

    1 Right-click the NE icon in the Main Topology and select [Delete].

    The Delete dialog box is displayed.

    2 Click . The NE icon is deleted from the Main Topology.

    2.1.4 Switching NE User

    Purpose

    For NE management, you usually need to select an NE user with the correspondingauthority level according to the operation type. To avoid conflict due to the login to

    the NE from different clients using the same NE user, you often need to switch theNE user.

    Prerequisites

    NM user with the authority of "system maintainer" or above.

    NE user has been created.

    Procedure

    Step Action

    1 Select [System/NE Security Management/NE Login Management]from the Main Menu.

    2 Select the NE with the NE user to be switched from the NE list, andclick the double-right-arrow button (red).

    3 Select the NE in NE Login Management. Click .The Switch Current NE User dialog box is displayed.

    Note:

    You can use or to select multiple NEs at one time.

  • 8/14/2019 Operation Manual for SDH

    66/416

    OptiX iManager T2000

    Operation Manual for SDH 2 Creating Topology

    Huawei Technologies Proprietary

    2-6

    Step Action

    4 Enter the name and password of the new NE user. Click .

    5 Click in the Operation Result dialog box.

    2.1.5 Creating Topology Subnet

    Purpose

    The subnet created here is a topological concept only. For the convenience ofmanagement, topology objects in the same area of a network or with similar

    attributes are usually arranged in one subnet for display.

    Prerequisite

    NM user with the authority of "system maintainer" or above.

    Procedure

    Step Action

    1 Right-click in the Main Topology and select [Create/Subnet].

    2 Select the tab Basic Attributes in the Create Subnet dialog box.Enter the attributes of the subnet.

  • 8/14/2019 Operation Manual for SDH

    67/416

    OptiX iManager T2000

    Operation Manual for SDH 2 Creating Topology

    Huawei Technologies Proprietary

    2-7

    Step Action

    3 Select the tab Object Selection and select the created NE from thecolumn Object Not Selected. Click the double-right-arrow button(red).

    4Click . Click in the Main Topology. The icon appears inthe position where you click.

  • 8/14/2019 Operation Manual for SDH

    68/416

    OptiX iManager T2000

    Operation Manual for SDH 2 Creating Topology

    Huawei Technologies Proprietary

    2-8

    2.2 Changing NE Attributes

    2.2.1 Changing NE Name and Remarks

    Purpose

    Use this procedure to change NE name and remarks.

    Prerequisite

    NM user with the authority of "system operator" or above.

    Procedure

    Step Action1 Right-click the NE icon in the Main Topology and select [Attribute].

    The NE Attribute dialog box is displayed.

    2 Enter the new NE name and remarks. Click .

  • 8/14/2019 Operation Manual for SDH

    69/416

    OptiX iManager T2000

    Operation Manual for SDH 2 Creating Topology

    Huawei Technologies Proprietary

    2-9

    2.2.2 Changing NE IP Address

    Purpose

    Use this procedure to change NE IP Address. Changing NE IP address may interruptthe communication between the NE and the NM.

    Prerequisite

    NM user with the authority of "system administrator" or above.

    Procedure

    Step Action

    1 Select [Communication/Communication Parameter Setting] in theDCN View.

    2 Select the NE and click the double-right-arrow button (red).

    3 Enter the new IP in the IP domain and click .

  • 8/14/2019 Operation Manual for SDH

    70/416

    OptiX iManager T2000

    Operation Manual for SDH 2 Creating Topology

    Huawei Technologies Proprietary

    2-10

    2.2.3 Changing NE Extended ID

    Purpose

    Use this procedure to change the NE Extended ID. Extended ID refers to the higher8 bits of the NE ID that are used to identify the subnet where the NE is located, andto distinguish different network segments in the WAN.

    Prerequisite

    NM user with the authority of "system