OPERATION MANUAL for Documents... · EXTENDED WARRANTY: The CSI-2100 Module, CSI-2140 Alarm Module,...
Transcript of OPERATION MANUAL for Documents... · EXTENDED WARRANTY: The CSI-2100 Module, CSI-2140 Alarm Module,...
OPERATIONMANUAL forCSI-2000 Hardline Communication Systems
This manual isavailable for download
on our website:
www.con-space.com/downloads
Look under 'Manuals'
CAUTIONPROPER TRAINING
The CSI-2000 Confined Space Communication System is a
safety system. It is designed to assist workers in the
accomplishment of their tasks, to make their jobs easier, more
relaxed and most of all, safer.
As no product can "guarantee" life protection, neither can the
CSI-2000, but properly used and maintained, this equipment
will provide a safer environment in which to work. Please
ensure that all users of this equipment are properly instructed
and knowledgeable as to the features and benefits of this and
any other equipment used.
BACK-UP COMMUNICATION
Prior to entry, CON-SPACE recommends that an alternate
method of communication be agreed to between all parties
involved, to be used in the unlikely event of a breakdown in
the CON-SPACE system. Remember, the prime issue is the
safety of the entrant and back-up procedures for all aspects of
an entry are necessary to ensure entrant safety.
CSI-2100 Command ModuleProblem Cause Solution
Will NOT Work Power switch in "OFF" position
Batteries are low/discharged
Batteries are installed incorrectly
Battery compartment lid is too tight or too loose
Turn switch to "ON" position
Replace with 'AA' ALKALINE Batteries. (See battery replacement instructions)
Check battery polarity
Loosen/tighten down battery compartment lid
Low/No Volume
Cannot communicate/ activate alarm when 2 CSI-2100 Modules are connected via expansion ports
Poor connection
Dirty contacts
Faulty/damaged expansion cable
Check cable connections
Clean contacts
Contact factory/distributor
Low/No VoiceTransmission
Loose mic connectors on headset or mic accessories
Volume controls set too low
Loose connection
Dirty connector contacts
Faulty-damaged cable
Faulty/damaged accessory (i.e. headset)
Noise reduction button depressed
Check 2 prong plug for proper connection
Adjust volume
Ensure cable/accessoryconnectors are correctly mated
Check contacts on connectors and clean to expose gold pins
Test cable, if faulty replace cable
Contact factory/distributor
Release noise reduction button
Volume controls set too low
Loose connection
Dirty connector contacts
Faulty/damaged cable
Faulty/damaged accessory (i.e. headsets)
Loose connector on speaker accessories
Noise reduction button depressed
Adjust volume
Ensure connectors are correctly mated
Check contacts on connectors and clean to expose gold plated pins
Test cable if faulty, replace cable
Contact manufacturer/distributor
Check plug for proper connection
Release noise reduction button
CSI-2100 Command Module cont'd.../Problem Cause Solution
Low Volume Poor connection
Volume control set too low
Dirty connection
Speaker filled with dirt or fluid
Operator accessory mic placement incorrect
Check connection
Adjust volume on CSI-1100.
Clean contacts
Clear out speaker (be careful not to puncture speaker cone)
Correctly position mic
Squeal/Feedback/Hum
Mics and speakers are too close together
Discharge batteries
Move accessories further apart or adjust volume to a lower setting
Replace with 'AA' ALKALINE Batteries. (See battery replacement instructions)
Cannot transmit
Clogged mic port
Poor connection
Dirty connector contacts
Clear out 5 small holes on Talk Box face (be careful not to pierce mic barrier beneath holes)
Check connection
Clean connector contacts
Alarm does not sound when Red alarm button is depressed
No Alarm Module Connected to CSI-2100
Poor connection
Dirty connection
Damaged/faulty cable
Faulty Talk Box
Connect an Alarm Module to CSI-2100
Check connection
Clean connector contacts
Replace cable
Contact manufacturer/distributor
Squeal/Feedback
Mic on other accessories too close to Talk Box
Faulty Talk Box
Talk Box connected to operator port
Two Talk Boxes
Mode Switch is set to "Normal"
Move mic further apart or adjust volume to a lower setting
Contact manufacturer/distributor
Cannot use Operator Port due to sidetone feature of that Port
Only one Talk Box can be used per system
Position Switch to "Talk Box" Mode
Talk Box, Power Talk Box & Other Listening Devices
CSI-2140 Alarm ModuleProblem Cause Solution
Low Volume Poor connection
Volume control set too low
Dirty connection
Speaker filled with dirt or fluid
Operator accessory mic placement incorrect
Check connection
Adjust volume on CSI-1100.
Clean contacts
Clear out speaker (be careful not to puncture speaker cone)
Correctly position mic
Cannot transmit
Clogged mic port
Poor connection
Dirty connector contacts
Clear out 5 small holes on Talk Box face (be careful not to pierce mic barrier beneath holes)
Check connection
Clean connector contacts
Alarm does not sound when Red alarm button is depressed
No Alarm Module Connected to CSI-2100
Poor connection
Dirty connection
Damaged/faulty cable
Faulty Talk Box
Connect an Alarm Module to CSI-2100
Check connection
Clean connector contacts
Replace cable
Contact manufacturer/distributor
Squeal/Feedback
Mic on other accessories too close to Talk Box
Faulty Talk Box
Talk Box connected to operator port
Two Talk Boxes
Mode Switch is set to "Normal"
Move mic further apart or adjust volume to a lower setting
Contact manufacturer/distributor
Cannot use Operator Port due to sidetone feature of that Port
Only one Talk Box can be used per system
Position Switch to "Talk Box" Mode
Hardline CableCable DoesNOT Work
Cables are hard to connect
Dry 'O' Ring
Poor Connection
Dirty connectors
Damaged/faulty Cable
"Wet" 'O' Ring, if possible usesilicone grease or vaseline (saliva can be used if nothing else is available)
Re-seat Connectors
Clean connector pins
Replace Cable
www.con-space.com
APPROVALSThe CSI-2000 Systems and accessories are Intrinsically Safe Approved in Canada, the United States and the European Community when powered by Energizer/Eveready E-93, EN-93 or Duracell MN-1400, PC-1400, 1.5V "C" size alkaline batteries and used in accordance with Control Drawing E-1040, Page 1-of-2. batteries
UNITED STATES FACTORY Class I,II,III, Division 1 MUTUAL Groups A,B,C,D,E,F,G, T3C
MSHA Meets the requirements of Title 30 Code of federal regulations, Part 23 and is approved for use in gassy mines. (methane air mixtures only) Approval No. 9B-199-0
CANADA CSA Class I, Division 1, Groups A,B,C,D; Class II, Group G and Coal Dust; Class III, T3C
EUROPEAN UNION INTERTEK WARRANTYCON-SPACE intercom modules and accessories except cables and cable assemblies are warranted for one year against defects in workmanship and materials. This does not include damage caused by mis-use and specifically excludes cable assemblies. No other warranties are expressed or implied.
EXTENDED WARRANTY: The CSI-2100 Module, CSI-2140 Alarm Module, and CSI-2130 Talk Box carry an extended one year warranty for a total of two years against defects in workmanship and materials. This does not include damage caused by mis-use and applies specifically to the Modules listed. No other warranties are expressed or implied.
ABOUT CON-SPACECON-SPACE was incorporated in 1991. Headquartered in Canada, the Company operates subsidiary offices in USA and UK and has Distributors in many other Countries. CON-SPACE helped to establish the Confined Space Industry and has extended its line of communication products to help people working in many hazardous environments.
CanadaHead Office & Manufacturing505 - 5600 Parkwood WayRichmond, B.C., V6V 2M2 Tel: (604) 244-9323 (800) 546-3405 Fax: (604) 270-2138 Email: [email protected]
USA Lincoln, Nebraska Office2606 Park Boulevard, Suite 2Lincoln, NE 68502-3349Tel: (402) 477-0086Fax: (402) 742-7880
Blaine, WA 98231-1540 Tel: (800) 546-3405 Fax: (800) 546-3410
UK & EuropeUnit 2 Stephenson Court, Brunel ParkNewark, Nottinghamshire NG24 2EGUnited KingdomTel: +44 (0) 1636 642484Fax: +44 (0) 1636 642485
Email: [email protected]
FOR MORE INFORMATION CONTACT OUR OFFICES:
Printed in Canada Nov 2006