OPERATING RANGE PRIUXPRIUX JETSON HOMEHOME · 2020. 3. 4. · - Salmson connector: no tools...

8
Hm Qm 3 /h 0 1 2 3 4 5 4 1 6 7 Priux home 80 Priux home 60 Priux home 40 For the accelerated circulation of hot water and iced water in the heating and air-condi- tioning circuits of single-family houses. New and old systems (renovation – extension) Installations with and without thermostati- cally controlled valves Installations with radiators and underfloor heating systems Thermosiphon-type installations OPERATING RANGE Flow rate of up to 5 m 3 /h Manometric head of up to 8 mWC Max. operating pressure 6 bar Min. suction pressure 0,3 bar at 95°C Temperature range -10°C at 95°C Max. ambient temperature +40°C EEI-Part 2 ≤0,20 The reference criterion for the most efficient circulating pumps is EEI ≤ 0,20 APPLICATIONS BENEFITS Completely interchangeable with exis- ting models •Simplified settings Easy replacement Installation and maintenance Energy savings Noise control • Salmson connector High-efficiency circulating pumps Heating – Air conditioning 50 Hz N.T. N o 111-18/ENG - Ed.3/06-14 PRIUX HOME 1

Transcript of OPERATING RANGE PRIUXPRIUX JETSON HOMEHOME · 2020. 3. 4. · - Salmson connector: no tools...

Page 1: OPERATING RANGE PRIUXPRIUX JETSON HOMEHOME · 2020. 3. 4. · - Salmson connector: no tools required - mmid eugcomAi t u t a. ng Activation of venting function • 10 min cycle to

Hm

Qm3/h0 1 2 3 4 5

4

1

6

7

Priux home 80

Priux home 60

Priux home 40

For the accelerated circulation of hot water and iced water in the heating and air-condi-tioning circuits of single-family houses.• New and old systems (renovation – extension)

• Installations with and without thermostati-cally controlled valves

• Installations with radiators and underfloor heating systems

• Thermosiphon-type installations

OPERATING RANGEFlow rate of up to 5 m3/hManometric head of up to 8 mWCMax. operating pressure 6 barMin. suction pressure 0,3 bar at 95°CTemperature range -10°C at 95°CMax. ambient temperature +40°CEEI-Part 2 ≤0,20The reference criterion for the most efficient circulating pumps is EEI ≤ 0,20

APPLICATIONS

BENEFITS• Completely interchangeable with exis-ting models

•  Simplified settings

• Easy replacement

• Installation and maintenance

• Energy savings

• Noise control

• Salmson connector

High-efficiency circulating pumpsHeating – Air conditioning

50 Hz

N.T. No 111-18/ENG - Ed.3/06-14

PRIUX HOMEJETSONPRIUX HOME

1

Page 2: OPERATING RANGE PRIUXPRIUX JETSON HOMEHOME · 2020. 3. 4. · - Salmson connector: no tools required - mmid eugcomAi t u t a. ng Activation of venting function • 10 min cycle to

DESIGN• Hydraulic part- Single housing with threaded port for direct fitting onto pipework.

• Motor- Single-phase, glandless, shaft bearings lubricated by the pumped fluid.

- Synchronous motor with ECM (Electronically Commuted Motor) technology, equipped with a permanent magnet rotor. The magne-tic field rotating around the stator is created by the electronic commutation of the coils.

Protection class: IP X2DMax. temperature of the conveyed fluid: TF 95EMC compliance: - 61000-6-1 - 61000-6-2 - 61000-6-3 - 61000-6-4

IDENTIFICATIONPriux home 4 0 - 25 / 180

High-efficiency pump Residential application

TDH at 0 m3/h

DN (nominal diameter) of ports:

Port-to-port distance of pump housing

BASIC CONSTRUCTIONMain parts MaterialPump housing Cast ironImpeller Composite materialShaft, jacket and air gap Stainless steelSuction ring Stainless steelShaft bearings GraphiteGasket Ethylene-propylene

BENEFITS• Energy savings - Conforms to the European Directive: E rP 2013 and ErP 2015.

- Energy savings of up to 90% compared to old-generation circulating pumps.

- Minimum consumption: 4 watts.- Display of current consumption.• Noise control- Elimination of whistling and hydraulic noises thanks to electronic speed variation.

• Completely interchangeable with exis-ting models

- 3 sizes of motors: 4 m, 6 m and 8 m.- Two types of port-to-port distances: 130 and 180 mm.

- All types of connections: 1", 1 1/2" and 2".

• Simplified settings - Just one setting dial.- LED display of the manometric head.- Choice of regulation mode according to the installation.

• Easy replacement- Markings for selecting the manometric head.• Installation and maintenance- Requires less space.- Salmson connector: no tools required- Automatic degumming.

Activation of venting function

• 10 min cycle to protect the system.

Selection of setting mode

•    pv (variable pressure) for systems with radiators

•    pc (constant pressure) for systems with underfloor heating. Salmson connector

• Tool-free connection. • Separation of electrical and hydraulic

connections for greater safety.

LED display• On installation, accurate setting

of the manometric head in increments of 0.1 m.

• Then display of current electric consumption to inform the user.

Electronic switching, permanent magnet motor

Just one setting dial• Markers showing

equivalence with the old 3-speed circulating pumps.

• Easy replacement.

Automatic degumming

PRIUX HOMEJETSONPRIUX HOME

2

Page 3: OPERATING RANGE PRIUXPRIUX JETSON HOMEHOME · 2020. 3. 4. · - Salmson connector: no tools required - mmid eugcomAi t u t a. ng Activation of venting function • 10 min cycle to

SETTINGS

Setting the Manometric Head

La rotation du bouton blanc permet d'afficher sur l'indicateur à LED la hauteur manomé-trique en m.

For easier settings, the white dial may be set to the symbols I, II or III on the Δpc scale, which are marker points showing equivalence with the old 3-speed circulating pumps.

Factory setting: ½ max. mano-metric head - Δpv.

Electricity consumption

In operating mode, the current power consumption is displayed in W.

With this regulation mode, the differential pressure (mano-metric head) can be reduced electronically in the event

of a reduction in the flow rate, according to the predefined differential pressure setpoint value.

Recommended regulation mode for heating systems with thermostatically controlled valves

With this regulation mode, the differential pressure of the circulating pump is kept at a constant level electronically,

regardless of the flow rate, according to the predefined pressure setpoint value.

Recommended regulation mode for installations with an underfloor heating system and for Thermosiphon-type installations.

Regulation function:

Venting function:

Primary purpose: When first started up, this function allows for the venting of air bubbles contained within

the Priux home rotor chamber.

Secondary purpose: This function also supports the venting of the heating system. As it operates, air bubbles trapped within the system are released and then conveyed to the highest point of the sys-tem (deaerator).

The "venting" function lasts for 10 minutes. After these 10 minutes, the manometric head must be reset, otherwise the circulating pump will return to the factory setting.

PRIUX HOMEJETSONPRIUX HOME

3

Page 4: OPERATING RANGE PRIUXPRIUX JETSON HOMEHOME · 2020. 3. 4. · - Salmson connector: no tools required - mmid eugcomAi t u t a. ng Activation of venting function • 10 min cycle to

0 0,5 1,0 1,5 2,0 2,50 0,2 0,4 0,6

0 2 4 6 8

0 1 2 3 4

0

1

2

3

4

0

10

20

30

40

0 0,5 1,0 1,5 2,0 2,50

5

10

15

0 0,4 0,8 1,2

0 0,2 0,4 0,6 0,8 1,0

Rp ½

Rp 1¼

Rp 1

1~230 V - Rp ½, Rp 1, Rp 1¼

∆p-c

max.

m/s

Ql/s

Q/Igpm

Qm³/h

Qm³/h

p/kPaHm

P1

max.

3m2m

0,5m

Priux home 40

0 1 2 3 40 0,2 0,4 0,6 0,8 1,0 1,2

0 4 8 12 16

0 0,4 0,8 1,2 1,6

0

1

2

3

4

5

6

0

10

20

30

40

50

60

0 1 2 3 40

10

20

30

max.

∆p-c

max.

0,5m

2m4m5m

0 0,5 1,0 1,5 2,0 2,50 1 2 3 4 5 6 7 Rp ½

Rp 1¼

Rp 1 m/s

Ql/s

Q/Igpm

Qm³/h

Qm³/h

p/kPaHm

P1

1~230 V - Rp ½, Rp 1, Rp 1¼Priux home 60

∆p-v

0 0,5 1,0 1,5 2,0 2,50

1

2

3

4

0

10

20

30

40

0 0,5 1,0 1,5 2,0 2,50

5

10

151m

2m3mmax.

max.

0 1 2 3 40 0,4 0,8 1,2

0 0,2 0,4 0,6 0,8 1,0

0 0,2 0,4 0,6

0 2 4 6 8

Rp ½

Rp 1¼

Rp 1 m/s

Ql/s

Q/Igpm

Qm³/h

Qm³/h

p/kPaHm

P1

1~230 V - Rp ½, Rp 1, Rp 1¼Priux home 40

0 1,0 2,0 3,00 0,2 0,4 0,6 0,8 1,0

0 4 8 12

0

1

2

3

4

5

6

0

10

20

30

40

50

60

0 1,0 2,0 3,00

10

20

30

max.

∆p-v

max.

1m2m4m

0 1 2 3 4 50 0,5 1,0 1,5 2,0

0 0,4 0,8 1,2

Rp ½

Rp 1¼

Rp 1 m/s

Ql/s

Q/Igpm

Qm³/h

Qm³/h

p/kPaHm

P1

1~230 V - Rp ½, Rp 1, Rp 1¼Priux home 60

HYDRAULIC PERFORMANCE

PRIUX HOMEJETSONPRIUX HOME

4

Page 5: OPERATING RANGE PRIUXPRIUX JETSON HOMEHOME · 2020. 3. 4. · - Salmson connector: no tools required - mmid eugcomAi t u t a. ng Activation of venting function • 10 min cycle to

0 0,4 0,8 1,2 1,6 2,0

0 0,5 1,0 1,5 2,0 2,5 3,0

Rp 1¼

Rp 1m/s

0 1 2 3 4 5

0 0,4 0,8 1,2

0 4 8 12 16

0

1

2

3

4

5

6

7

0

10

20

30

40

50

60

70

0 1 2 3 4 50

20

40

60

Ql/s

Q/Igpm

Qm³/h

Qm³/h

p/kPa

1m

2m4m6m

1~230 V - Rp 1, Rp 1¼

∆p-v

max.

Hm

P1

max.

Priux home 80

0 1 2 3 4 5

0 0,4 0,8 1,2

0 0,4 0,8 1,2 1,6 2,0

0 0,5 1,0 1,5 2,0 2,5 3,0

0 4 8 12 16

0

1

2

3

4

5

6

7

0

10

20

30

40

50

60

70

0 1 2 3 4 50

20

40

60

Rp 1¼

Rp 1

0,5m

2m5m6m

1~230 V - Rp 1, Rp 1¼

∆p-c

max.

Ql/s

Q/Igpm

Qm³/h

Qm³/h

m/s

p/kPaHm

P1

max.

Priux home 80

HYDRAULIC PERFORMANCE

QUICK SETTING HELP

Heating system Regulation mode Size of system Priux home

With thermostatically controlled valvesUp to 15 radiators Priux home 40Up to 20 radiators Priux home 60Up to 25 radiators Priux home 80

Underfloor heating systemUp to 120 m² Priux home 40Up to 220 m² Priux home 60

> 220 m² Priux home 80

Thermosiphon type - Priux home 40

values given for information only

PRIUX HOMEJETSONPRIUX HOME

5

Page 6: OPERATING RANGE PRIUXPRIUX JETSON HOMEHOME · 2020. 3. 4. · - Salmson connector: no tools required - mmid eugcomAi t u t a. ng Activation of venting function • 10 min cycle to

12 3

4 5 61

2

3

12 3

4 5 61

2

3

12 3

4 5 61

2

3

12 3

4 5 61

2

3

12 3

4 5 61

2

3

Priux home 40

Priux home 40

Priux home 60

Priux home 60

Priux home 80

Priux home 80

Longueuraller-retour de la boucle la plus

défavorisée Valeur de réglage de la consigne

30 m 1,3 1,3 1,0 1,0 1,2 1,1 1,3 1,2 1,240 m 1,5 1,3 1,3 1,0 1,4 1,3 1,5 1,3 1,350 m 1,8 1,5 1,5 1,3 1,8 1,7 1,7 1,4 1,460 m 2,3 2,0 1,8 2,2 2,0 1,8 2 1,8 1,580 m 2,5 2,3 2,9 2,6 2,4 2,5 2,4 2,1100 m 2,8 2,5 3,2 3,0 2,8 2,9 2,7120 m 3,0 4,0 3,5 3,2 3,4 3,3 3140 m 5,6 4,8 4,4 4 3,8 3,6160 m 5,9 5,4 4,8 4,4 4,2 4180 m 6,6 5,8 5,4 4,8 4,6

Débit (m3/h) 0,5 1 1,5 2 2,5 3 3,5 4 4,5

Siriux Master

Longueuraller-retour

de la bouclePER 16 x 20

Valeur de réglage de la consigne

20 m 1,0 1,0 1,0

40 m 2,0 2,0 2,060 m 3,0 3,0 3,080 m 4,0 4,0

100 m 5,0 5,0 120 m 6,0 140 m 7,0

Flow rate (m3/h) 0,5 1 1,5 2 2,5 3 3,5 4 4,5

Siriux Master

Longueuraller-retour

de la bouclePER 13 x 16

Valeur de réglage de la consigne

20 m 1 1,5 1,540 m 3,0 3,0 3,060 m 4,5 4,5 80 m 6,0

100 m 7,5 120 m 140 m

Flow rate (m3/h) 0,5 1 1,5 2 2,5 3 3,5 4 4,5

Siriux Master

ELECTRICAL CONNECTIONSQuick electrical connections requiring no tools

QUICK SETTING HELP

For systems with underfloor heating

For systems with radiators

Outward and inward length of the least favourable loop Setpoint value setting

30 m 1,3 1,3 1,0 1,0 1,2 1,1 1,3 1,2 1,240 m 1,5 1,3 1,3 1,0 1,4 1,3 1,5 1,3 1,350 m 1,8 1,5 1,5 1,3 1,8 1,7 1,7 1,4 1,460 m 2,3 2,0 1,8 2,2 2,0 1,8 2 1,8 1,580 m 2,5 2,3 2,9 2,6 2,4 2,5 2,4 2,1100 m 2,8 2,5 3,2 3,0 2,8 2,9 2,7120 m 3,0 4,0 3,5 3,2 3,4 3,3 3140 m 5,6 4,8 4,4 4 3,8 3,6160 m 5,9 5,4 4,8 4,4 4,2 4180 m 6,6 5,8 5,4 4,8 4,6

Débit (m3/h) 0,5 1 1,5 2 2,5 3 3,5 4 4,5

Siriux Master

Outward and inward length of the 16 x 20

CLP loopSetpoint value setting

20 m 1,0 1,0 1,0

40 m 2,0 2,0 2,060 m 3,0 3,0 3,080 m 4,0 4,0

100 m 5,0 5,0 120 m 6,0 140 m 7,0

Flow rate (m3/h) 0,5 1 1,5 2 2,5 3 3,5 4 4,5

Siriux Master

Outward and inward length of the 13 x 16

CLP loopSetpoint value setting

20 m 1 1,5 1,540 m 3,0 3,0 3,060 m 4,5 4,5 80 m 6,0

100 m 7,5 120 m 140 m

Flow rate (m3/h) 0,5 1 1,5 2 2,5 3 3,5 4 4,5

Siriux Master

NB : These setpoint values are given for information only; the flow rate can be adjusted in the following manner:  Lowest setpoint value = reduction of flow rate  Highest setpoint value = increased flow rate, within the limits of the circulating pump's performance

PRIUX HOMEJETSONPRIUX HOME

6

Page 7: OPERATING RANGE PRIUXPRIUX JETSON HOMEHOME · 2020. 3. 4. · - Salmson connector: no tools required - mmid eugcomAi t u t a. ng Activation of venting function • 10 min cycle to

4 x VIS4 x SCREWS

b1 = 75

b3 = 37 b5 = 38

78

b2 = 81

b2 =

81

D

D

D

l0 =

180

l0 =

130

l3 =

90

l3 =

65

a = 34 L4

L1

46,7

54,2

b4 =

62

PLAQUE D’IDENTITENAMEPLATE

Référence commande

Moteur Pompe

P1 (W) I(A) Vitesse (tr/min) L0 (mm)

L1 (mm)

L3 (mm)

L4 (mm) Ø D Poids

(kg)Min Max Min Max Min Max

Priux home 40-25 / 180 mm

4W 20W 0,04 0,26 800 3600180 127 90 107

1"1/2

2Priux home 40-32 / 180 mm 2"Priux home 40-15 / 130mm

130 127 65 1071"

Priux home 40-25 / 130mm 1"1/2Priux home 60-25 / 180 mm

4W 40W 0,04 0,44 800 4700180 127 90 107

1"1/2

2Priux home 60-32 / 180 mm 2"Priux home 60-15 / 130mm

130 127 65 1071"

Priux home 60-25 / 130mm 1"1/2Priux home 80-25 / 180mm

4W 75W 0,04 0,66 800 5000180 135 90 115

1"1/22,3Priux home 80-32 / 180mm 2"

Priux home 80-25 / 130mm 130 135 65 115 1"1/2

INSTALLATION POSITIONS

ELECTRICAL AND DIMENSIONAL SPECIFICATIONS

Order reference

Motor Pump

P1 (W) I(A) Speed (rpm) L0

(mm)L1

(mm)L3

(mm)L4

(mm) Ø D Weight (kg)

Min Max Min Max Min Max

PRIUX HOMEJETSONPRIUX HOME

7

Page 8: OPERATING RANGE PRIUXPRIUX JETSON HOMEHOME · 2020. 3. 4. · - Salmson connector: no tools required - mmid eugcomAi t u t a. ng Activation of venting function • 10 min cycle to

Référence commandeRaccordement sur tube fileté

1/2" 3/4" 1" 1"1/4 2"

Priux home 40-25 / 180 mm _ RED 2027 RU 2634 _ _

Priux home 40-32 / 180 mm _ _ RED 2634 RU 3342 RU 4049

Priux home 40-15 / 130mm RU 1521 _ _ _ _

Priux home 40-25 / 130mm RED 2027 RU 2634 _ _

Priux home 60-25 / 180 mm _ RED 2027 RU 2634 _ _

Priux home 60-32 / 180 mm _ _ RED 2634 RU 3342 RU 4049

Priux home 60-15 / 130mm RU 1521 _ _ _ _

Priux home 60-25 / 130mm _ RED 2027 RU 2634 _ _

Priux home 80-25/180 mm _ RED 2027 RU 2634 _ _

Priux home 80-32/180 mm _ RED 2634 RU 3342 RU 4049

Priux home 80-25/130 mm _ RED 2027 RU 2634 _ _

SPECIFICITIESa) Electrical- 230 V - 50 Hz single-phase (60Hz).- Motor protection by a circuit breaker is not essential.

b) Installation- Motor axis always horizontal.- Connection to system by pipe unions.

c) Packaging- Delivered with connector and gaskets, wit-hout pipe unions.

d) Maintenance- Standard exchange of the appliance.

• Shut-off ball valve RU 2634 - Ref. 4104734

• Pipe union

ACCESSORIES

• ØG 1”1/2 - 2” Adapter rings Ref. 4051850

• Insulating housing Ref. 4160237 • 2 m cable with side connector (in sets of 10) Ref. 4164854

Order referenceThreaded tube connection

1/2" 3/4" 1" 1"1/4 2"

PRIUX HOMEJETSONPRIUX HOME

8