FibreCAT SX Series
Operating Manual
-
7/23/2019 Operating Manual-sx60-100 Om 090824
2/112
Comments Suggestions Corrections
The User Documentation Department would like to know your
opinion on this manual. Your feedback helps us to optimize our
documentation to suit your individual needs.
Feel free to send us your comments by e-mail to:
Certified documentation
according to DIN EN ISO 9001:2000
To ensure a consistently high quality standard and
user-friendliness, this documentation was created to
meet the regulations of a quality management system whichcomplies with the requirements of the standard
DIN EN ISO 9001:2000.
cognitas. Gesellschaft fr Technik-Dokumentation mbH
www.cognitas.de
Copyright and Trademarks
This manual is printedon paper treated withchlorine-free bleach.
Copyright Fujitsu Technology Solutions GmbH 2009.
All rights reserved.
Delivery subject to availability; right of technical modifications reserved.
All hardware and software names used are trademarks of their respective manufacturers.
mailto:[email protected]://www.cognitas.de/mailto:[email protected]://www.cognitas.de/ -
7/23/2019 Operating Manual-sx60-100 Om 090824
3/112
FibreCAT SX Series Operating Manual
Contents
1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.1 Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.2 Management Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.2.1 FibreCAT SX Manager Web-Based Interface . . . . . . . . . . . . . . . . . . . . . .
1.2.2 FibreCAT SX Manager Command-Line Interface . . . . . . . . . . . . . . . . . . . . 1.3 Target Group of the Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.4 Structure of the Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.5 Notational Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
1.6 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
1.7 Installation and Configuration Checklist . . . . . . . . . . . . . . . . . . . . . . 1
2 Important Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
2.1 Notes on Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
2.2 Electrostatic-sensitive Component Label . . . . . . . . . . . . . . . . . . . . . . 1
2.3 CE Certificate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
2.4 RFI Suppression . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
2.5 Notes on Mounting the Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
2.6 Notes on Transportation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
2.7 Environmental Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
2.8 Site Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
2.8.1 Physical Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
2.8.1.1 Dimension and Weight Specifications . . . . . . . . . . . . . . . . . . . . . . . 2
2.8.1.2 Weight and Placement Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . 2
2.8.1.3 Ventilation Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
2.8.2 Environmental Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
-
7/23/2019 Operating Manual-sx60-100 Om 090824
4/112
Contents
FibreCAT SX Series Operating Manual
2.8.3 Electrical Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
2.8.3.1 Electrical Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
2.8.3.2 Site Wiring and Power Requirements . . . . . . . . . . . . . . . . . . . . . . . . 25
2.8.3.3 Cabling Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
2.8.4 Management Host Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
3 Hardware, Operating, and Indicator Components . . . . . . . . . . . . . . . . . . 27
3.1 Controller Enclosure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
3.1.1 Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
3.1.2 Components and Indicators at the Front Side . . . . . . . . . . . . . . . . . . . . . 28
3.1.3 Ports and Switches at the Back Side . . . . . . . . . . . . . . . . . . . . . . . . . . 29
3.1.4 Indicators at the Back Side . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
3.2 Expansion Enclosure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 333.2.1 Components. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
3.2.2 Components and Indicators at the Front Side . . . . . . . . . . . . . . . . . . . . . 33
3.2.3 Ports and Switches at the Back Side . . . . . . . . . . . . . . . . . . . . . . . . . . 33
3.2.4 Indicators at the Back Side . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
4 Connecting Hosts / Configurations . . . . . . . . . . . . . . . . . . . . . . . . . 37
4.1 Connecting Remote Management Hosts . . . . . . . . . . . . . . . . . . . . . . . 37
4.2 Installing the SCSI Enclosures Services Driver . . . . . . . . . . . . . . . . . . . 37
4.3 Connecting Direct Attached iSCSI Configurations . . . . . . . . . . . . . . . . . 38
4.3.1 Single Controller FibreCAT SX80 iSCSI With One Host . . . . . . . . . . . . . . . . 38
4.4 Host Interface Speed for FibreCAT SX (FC) . . . . . . . . . . . . . . . . . . . . . 39
4.5 Connecting Direct Attached FC Configurations . . . . . . . . . . . . . . . . . . . 41
4.5.1 FibreCAT SX60 / SX80 / SX88 With One Dual Port Host . . . . . . . . . . . . . . . . 42
4.5.2 FibreCAT SX60 / SX80 / SX88 With Two Dual Port Hosts . . . . . . . . . . . . . . . 43
4.5.2.1 Controller Failover Scenario . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
4.5.2.2 Path Failover Scenario . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
4.5.3 FibreCAT SX60 / SX80 / SX88 With Two Dual Port Hosts for High Performance . . . . 46
4.5.4 FibreCAT SX100 With Four Dual-Port Hosts . . . . . . . . . . . . . . . . . . . . . . 47
4.5.4.1 Controller Failover Scenario . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
4.6 Connecting Switch Attached iSCSI Configurations . . . . . . . . . . . . . . . . . 50
4.6.1 FibreCAT SX80 iSCSI With Two Dual Port Hosts and Two Switches . . . . . . . . . . 50
4.6.1.1 Controller Failover Scenario . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
-
7/23/2019 Operating Manual-sx60-100 Om 090824
5/112
Conten
FibreCAT SX Series Operating Manual
4.7 Connecting Switch Attached FC Configurations . . . . . . . . . . . . . . . . . . 5
4.7.1 FibreCAT SX60 / SX80 / SX88 With One Switch and One Dual Port Host . . . . . . . 5
4.7.2 FibreCAT SX60 / SX80 / SX88 With Two Switches and One Dual Port Host . . . . . 5
4.7.2.1 Configuration Rules for VMware ESX Server 3.0.0 and 3.0.1 . . . . . . . . . . . 5
4.7.3 FibreCAT SX60 / SX80 / SX88 With Two Switches and Two Dual Port Hosts . . . . . 54.7.4 FibreCAT SX100 With One Switch and Two Dual-Port Hosts . . . . . . . . . . . . . 5
4.8 Supported HBAs for Solaris (SPARC) . . . . . . . . . . . . . . . . . . . . . . . . 5
5 Installing Enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
5.1 Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
5.2 Unpacking an Enclosure and Verifying its Contents . . . . . . . . . . . . . . . . 6
5.3 Preparing the Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65.4 Installing an Enclosure in a Rack . . . . . . . . . . . . . . . . . . . . . . . . . . 6
5.4.1 Rack-Mount Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
5.4.2 Rack Mounting Position Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
5.4.3 Mounting Steps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
5.5 Connecting Controller and Expansion Enclosures . . . . . . . . . . . . . . . . . 6
5.6 Connecting the AC Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
5.7 Testing the Enclosure Connections . . . . . . . . . . . . . . . . . . . . . . . . . 7
6 Configuring a System for the First Time . . . . . . . . . . . . . . . . . . . . . . 7
6.1 Setting the IP Address Using the CLI . . . . . . . . . . . . . . . . . . . . . . . . 7
6.2 FibreCAT SX Manager Web-Based Interface . . . . . . . . . . . . . . . . . . . . 7
6.2.1 Configuring Your Web Browser for the WBI . . . . . . . . . . . . . . . . . . . . . . 7
6.2.2 Logging In to WBI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
6.2.3 Setting Date and Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
6.3 Driver Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
6.4 Configuring Controller Enclosure Host Ports (FC) . . . . . . . . . . . . . . . . . 7
6.5 Configuring the Microsoft iSCSI Software Initiator (iSCSI) . . . . . . . . . . . . 7
6.6 Editing Registry Timeout Values for iSCSI Initiator . . . . . . . . . . . . . . . . 8
6.7 Install Native MPIO Functionality Under Windows 2008 for FibreCAT SX . . . . 8
6.8 Installing a License . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
-
7/23/2019 Operating Manual-sx60-100 Om 090824
6/112
Contents
FibreCAT SX Series Operating Manual
6.9 Creating Virtual Disks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
6.10 Volume Mappings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
6.11 Testing the Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
6.12 Logging Out of the WBI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
6.13 Next Steps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
7 Powering the System Off and On . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
7.1 Powering Off the System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
7.2 Powering On the System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
Glossary and Abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
Figures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107
Related Documents and Links . . . . . . . . . . . . . . . . . . . . . . . . . . . 109
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111
-
7/23/2019 Operating Manual-sx60-100 Om 090824
7/112
FibreCAT SX Series Operating Manual
1 Introduction
This guide describes how to install, initially configure and operate FibreCATSX series
storage system, and applies to the following models:
FibreCAT SX60 Fibre Channel (FC) Controller Enclosure
FibreCAT SX80 Fibre Channel (FC) Controller Enclosure
FibreCAT SX88 Fibre Channel (FC) Controller Enclosure
FibreCAT SX80 iSCSI Controller Enclosure
FibreCAT SX100 Fibre Channel (FC) Controller Enclosure
FibreCAT SX Serial Attached SCSI (SAS) Expansion Enclosure
This guide does not apply to the FibreCAT SX40 model which is covered by separate
documents.
If there are no differences between the five controller enclosure models, from now on the
together are referred to as FibreCAT SX controller enclosure.
1.1 Product Overview
FibreCAT SX storage systems are high-performance storage solutions that combine
outstanding performance with high reliability, availability, flexibility, and manageability.
FibreCAT SX storage systems are modular, rackmountable, and scalable from a single
controller enclosure configuration to a maximum configuration of eight expansion enclo-
sures behind one controller enclosure.
A controller enclosure can contain two RAID controller modules, which interact and provid
failover capability for the data path. The enclosures can use SAS (with SX80 / SX88 /SX10
only) or SATA disk drives and provides RAID functionality, caching, and disk storage.
The different characteristics of the FibreCAT SX models are itemized in Technical Data o
page 11.
The enclosures can be installed in Fujitsu PRIMECENTER racks or in standard 19-inch EI
racks.
-
7/23/2019 Operating Manual-sx60-100 Om 090824
8/112
Management Software Introduction
8 FibreCAT SX Series Operating Manual
1.2 Management Software
The embedded management software FibreCAT SX Manager (FSM) includes the tools
outlined in the following topics:
FibreCAT SX Managers Web Based Interface (WBI) FibreCAT SX Managers Command Line Interface (CLI)
1.2.1 FibreCAT SX Manager Web-Based Interface
The FSM web based interface (WBI) is the primary interface for configuring and managing
FibreCAT SX family arrays. A web server resides in each controller module. WBI enables
you to manage FibreCAT SX family arrays from a web browser that is properly configured
and that can access a controller module through an Ethernet connection.
The WBI also includes monitoring and diagnostic features that enable you to view and
collect information that enhances the reliability, availability, and serviceability (RAS) of
FibreCAT SX family arrays. You can configure the transmission of event notifications(alerts), which can be sent to the screen or to email addresses, and Simple Network
Management Protocol (SNMP) traps, which can be sent to a host system. Events are
recorded in an event log, which you can view.
Information about using the WBI is in its online help and in the FibreCAT SX Series Admin-
istrators Guide.
To access the WBI for the first time, each FibreCAT SX controller module has a default IP
address (IP 10.0.0.1 and Subnet Mask 255.255.255.0). It can be used if the IP address
setting via CLI (see Setting the IP Address Using the CLI on page 73) can not be
performed, e. g. the appropriate serial cable is not on hand.
1.2.2 FibreCAT SX Manager Command-Line Interface
The FSM embedded command line interface (CLI) enables you to configure and manage
an array using individual commands or command scripts through an out-of-band RS-232 or
Ethernet connection.
NOTE
As first time configuration of a FibreCAT SX controller enclosure the IP addresses
of its RAID controller(s) is/are to be set. This step can only be performed by using
the CLI through a RS-232 connection, which you will do in Setting the IP Address
Using the CLI on page 73.
All subsequent usage of the CLI can be performed with a terminal emulationthrough an Ethernet connection.
Information about using the CLI is in the FibreCAT SX Manager Command Line Interface
(CLI) manual.
i
-
7/23/2019 Operating Manual-sx60-100 Om 090824
9/112
Introduction Target Group of the Manu
FibreCAT SX Series Operating Manual
1.3 Target Group of the Manual
The operating instructions are intended for the person responsible for installing the
hardware and correctly operating the system. The operating instructions contain all the
descriptions which are of importance for commissioning your FibreCAT SX storage system
in so far as they do not form part of the publication of your server system.
To understand the different expansion options it is necessary to have a knowledge of
hardware and data transmission, as well as basic knowledge of the operating system use
1.4 Structure of the Manual
This manual consists of the following chapters:
Important NotesThis chapter contains instructions on the safe operation of your storage system as we
as information about environmental protection and site requirements.
Hardware, Operating, and Indicator Components
This chapter gives a detailed description of the main hardware components and the
position and meaning of the operating and indicator elements.
Connecting Hosts / Configurations
This chapter shows some typical configurations.
Installing Enclosures
This chapter describes the process of installing FibreCAT SX enclosures in a
PRIMECENTER rack or in a standard 19-inch EIA rack cabinet, cable a controller
enclosure to expansion enclosures, and describes how to connect the power cords an
how to test the connections.
Connecting Hosts (FC)
This chapter describes the FibreCAT SX system cable connections to hosts for sever
different configurations.
Configuring a System for the First Time
This chapter describes how to use the CLI and the WBI of the FibreCAT SX Manage
to perform first-time configuration. The chapter also gives an overview about the
needed driver settings and describes how to perform basic storage configuration to
verify that your system is working.
Powering the System Off and On
This chapter describes how to power off and power on the system when needed.
http://s60_80.pdf/http://s60_80.pdf/ -
7/23/2019 Operating Manual-sx60-100 Om 090824
10/112
Notational Conventions Introduction
10 FibreCAT SX Series Operating Manual
1.5 Notational Conventions
Italics Commands, options, file names and path names are written in italic lettersin continuous text.
fixed font Commands and options in syntax descriptions as well as system outputare written in a fixed font.
Angle brackets are used to enclose variables which are to be replaced by
actual values.
semi-bold Highlights text
Quotation marks References to documents and chapters or sections in this or other documents
I NOTE Important information and tips
V CAUTION Reference to hazards that can lead to personal injury, loss of data or
damage to equipmentTable 1: Typographic Conventions
-
7/23/2019 Operating Manual-sx60-100 Om 090824
11/112
Introduction Technical Da
FibreCAT SX Series Operating Manual 1
1.6 Technical Data
General SpecificationsFibreCAT
SX60 SX80 / SX88 SX100 SX80 iSCSIType 4 Gbit/s
storage system
1 Gbit/s
storage system
Rack space 2U / enclosure
Number of hard disk drives max. 12 / enclosure
Supported operating systems Windows 2003 R2, Windows 2008
Red Hat 4.x and 5.x
SuSE SLES 9 and 10
VMware ESX
2.53 and 3.x
VMware ESX
3.x
VMware ESX
3.0, 3.0.1, 3.0.2
--- SPARC Solaris9 and 10
SPARC Solaris10
---
Number of power supplies 2 / enclosure
hot plug and with full redundancy
Controller cache memoryper RAID controller
512 MByte 1 GByte
FibreCAP per RAID controller 1
Number of
FC ports with SFP transceiver
(Small Form-factor Pluggable)
or RJ45 Ethernet ports(for iSCSI
per RAID controller
2 4 2
Number of snapshots (default) 4
Number of snapshots (with license) 16 32 244 32
Max. number of expansion enclo-
sures per controller enclosure1 4 8 4
Table 2: General Specifications
-
7/23/2019 Operating Manual-sx60-100 Om 090824
12/112
Technical Data Introduction
12 FibreCAT SX Series Operating Manual
Hard Disk DrivesFibreCAT
SX60 SX80 / SX88 SX100 SX80 iSCSI
Gross capacity1SATA II 7200 rpm2HDD
500 GByte750 GByte
1 TByte
Gross capacity1SAS115000 rpm2HDD
(available for SX80 / SX88 /
SX 100 only)
1 mixing with SATA HDDs possible
146 GByte
300 GByte
450 GByte
Access time
with SATA II HDDs11ms / 12ms (read / write)
Access time with SAS HDD 4ms / 5ms (read / write
Total capacity including the max.number of expansion enclosures 24 TByte(24 x 1 TByte) 56 TByte(56 x 1 TByte) 108 TByte(108 x 1 TByte) 56 TByte(56 x 1 TByte)
Table 3: Hard Disk Drives
Supported RAID Levels
RAID 0 Data Striping about several hard disk drives (HDDs)
RAID 1 Mirrored HDDs
RAID 10 Data mirroring, then Striping of the data over servers HDDs
RAID 3 Data Striping with dedicated parity HDD
RAID 5 Data Striping with distributed parity
RAID 50 RAID 5 arrays, Striped again over all drives
RAID 6 Data Striping with double parity
Table 4: Supported RAID Levels
-
7/23/2019 Operating Manual-sx60-100 Om 090824
13/112
Introduction Technical Da
FibreCAT SX Series Operating Manual 1
Management
Diagnostics of non-data
characteristics
Signalling and monitoring via SES (SCSI enclosure services) protocol and
LEDs
Management interfaces RS232 (mini-DB9)
10/100 Ethernet (RJ45)
Supported protocol SNMP
Administration FibreCAT SX Manager (FSM) with web based interface (WBI)
and command line interface (CLI)
Table 5: Management
Options FibreCATSX60 SX80 / SX88 SX100 SX80 iSCSI
HDDs Hot plug HDDs (SATA and SAS, mixing possible)
RAID controller 2nd RAID controller
Max. number of expansion enclo-
sures per controller enclosure1 4 8 4
Table 6: Options
Electrical Values per Enclosure (Maximum Values)
Power supply 2 hot-plug redundant modules with 1 fan integrated each
Apparent power 600 W (230 V AC, 50 Hz)
Max. electric current 2.61 A (230 V AC, 50 Hz)
Continuous load 535 W
Max. real ower 572 W (230 V AC, 50 Hz)
Power factor 0.953 (230 V AC, 50 Hz)
Peak load 650 W
Rated voltage 115 V 240 V
Rated frequency 50 HZ 60 Hz
Table 7: Electrical Values per Enclosure
-
7/23/2019 Operating Manual-sx60-100 Om 090824
14/112
Technical Data Introduction
14 FibreCAT SX Series Operating Manual
Ambient Conditions (DIN EN 60721-3-X)
Operating temperature 5C up to 40C (IEC 721)
Non operating temperature -40C to 70C
Relative humidity 10% 90% (non condensing)
Table 8: Ambient Conditions
Heat Dissipation per Enclosure
Max. heat dissipation 1926 kJ/j
Table 9: Heat Dissipation per Enclosure
Dimensions per Enclosure
Rack space (H x W x D)
H
WD
3,45 Inch / 8,75 cm (2 U)
17,56 Inch / 44,60 cm22,5 Inch / 57,15 cm
Weight max. 33.6 kg (dependent on configuration level)
Table 10: Dimensions per Enclosure
Compliance with Standards
Product safety UL listet, cUL, CE, CSA-C22.2, EN 60950-2000,
IEC 60950, GS, GOST, S-Mark
Approval GS, CSAUS/C, CB-certificate
Electromagnetic compatibility FCC Part 15 Class B, ICES-003, EN 300-386,
EN 55022 Class B, VCCI Class B, AS/NZS 3548 Class B,BMSI Class B
Vibrations EN 61000-3, EN 61000-3-3
Immunity EN 300-386, EN 55024CE certification EU Directive: 89/336/EWG (EMV);
EN61000-3-2;
EN 6100-3-3 73/23/EWG (Product security)
Environmental compliance RoHS compliant, WEEE compliant
Table 11: Compliance with Standards
-
7/23/2019 Operating Manual-sx60-100 Om 090824
15/112
Introduction Installation and Configuration Checkli
FibreCAT SX Series Operating Manual 1
1.7 Installation and Configuration Checklist
Before you begin to install the system, make sure you have read the Safety manual.
The following table outlines the steps required to install and initially configure the systemTo ensure a successful installation, perform the tasks in the order in which they are
presented.
Step Task
1 Verify the site installation requirements (see page 22)
2 Install the enclosures (see page 61)
3 Cabling the enclosures (see page 69)
4 Connect the power cords (see page 72)
5 Test the enclosure connections (see page 72)
6 Connect the hosts (see page 69)7 Configure a system for the first time (see page 73
Table 12: Installation and Configuration Checklist
http://s60_80.pdf/http://s60_80.pdf/ -
7/23/2019 Operating Manual-sx60-100 Om 090824
16/112
-
7/23/2019 Operating Manual-sx60-100 Om 090824
17/112
FibreCAT SX Series Operating Manual 1
2 Important Notes
2.1 Notes on Safety
In this section you will find information that you must note when using the storage system
This device complies with the relevant safety standards for IT equipment.
I The following safety notes are also provided in the Safety manual. Also payattention to the notes in the operating manual of the connected system.
If you have any questions relating to setting up and operating your system in the
environment where you intend to use it, please contact your sales outlet or our customer
service team.
V CAUTION! The actions described in these instructions should only be performed by
technical specialists. Equipment repairs should only be performed by service
personnel. Any unauthorized openings and improper repairs could expose th
user to risks (electric shock, energy hazards, fire hazards) and could also
damage the equipment. Please note that any unauthorized openings of thedevice will result in the invalidation of the warranty and exclusion from all liabili
Transport the device in its original packaging or in other suitable packaging
which will protect it against shock or impact.
Read the notes on environmental conditions in Technical Data on page 11
before setting up and operating the device.
If the device is brought in from a cold environment, condensation may form bot
inside and on the outside of the machine.
Wait until the device has acclimatized to room temperature and is absolutely dr
before starting it up. Material damage may be caused to the device if thisrequirement is not observed.
Check that the rated voltage specified on the type label is the same as the loca
line voltage.
-
7/23/2019 Operating Manual-sx60-100 Om 090824
18/112
Notes on Safety Important Notes
18 FibreCAT SX Series Operating Manual
V CAUTION! The device must only be connected to a properly grounded wall outlet (the
device is fitted with a tested and approved power cable).
Make sure that the power sockets on the device and the protective groundedoutlet of the buildings wiring system is freely accessible.
Switching off the device does not cut off the supply of power. To do this you must
remove the power plugs.
Before opening the unit, switch off the device and then pull out the power plugs.
Route the cables in such a way that they do not form a potential hazard (make
sure no-one can trip over them) and that they cannot be damaged. When
connecting up a device, refer to the relevant notes in this manual.
Never connect or disconnect data transmission lines during a storm (lightning
hazard).
Systems which comprise a number of cabinets must use a separate fused
socket for each cabinet.
The servers and the directly connected external storage subsystems should be
connected to the same power supply distributor. Otherwise you run the risk of
losing data if, for example, the central processing unit is still running but the
storage subsystem has failed during a power failure.
Make sure that no objects (such as bracelets or paper clips) fall into or liquids
spill into the device (risk of electric shock or short circuit).
In emergencies (e.g. damage to housings, power cords or controls or ingress ofliquids or foreign bodies), immediately power down the device, pull out the
power plugs and notify your service department.
Note that proper operation of the system (in accordance with IEC 60950/DIN
EN 60950) is guaranteed only if slot covers are installed on all vacant slots
and/or dummies on all vacant bays and the housing cover is fitted (cooling, fire
protection, RFI suppression).
-
7/23/2019 Operating Manual-sx60-100 Om 090824
19/112
Important Notes Electrostatic-sensitive Component Lab
FibreCAT SX Series Operating Manual 1
2.2 Electrostatic-sensitive Component Label
Electrostatic-sensitive components may be identified by the following sticker:
You must follow the instructions below when handling modules containing electrostatic-
sensitive components
Discharge static electricity from your body (for example by touching a grounded metaobject) before handling modules containing electrostatic-sensitive components.
The equipment and tools you use must be free of static charge.
Remove the power plug before installing or removing modules containing electrostatisensitive components.
Only hold modules containing electrostatic-sensitive components by their edges.
Do not touch any of the pins or track conductors on a module containingelectrostatic-sensitive components.
Use a grounding strap designed for the purpose, to connect you to the system unit a
you install the modules. Place all components on a static-safe base.
I An exhaustive description of the handling of modules containing electrostatic-sensitive components can be found in the relevant European and international
standards (DIN EN 61340-5-1, ANSI/ESD S20.20).
2.3 CE Certificate
The shipped version of this device complies with the requirements of the EEC
directives 89/336/EEC Electromagnetic compatibility and 73/23/EEC Low
voltage directive. The device therefore qualifies for the CE certificate
(CE=Communaut Europenne).
-
7/23/2019 Operating Manual-sx60-100 Om 090824
20/112
RFI Suppression Important Notes
20 FibreCAT SX Series Operating Manual
2.4 RFI Suppression
All other equipment which is connected to this product must also have radio noise
suppression in accordance with EC Guideline 89/336/EWG.
Products which meet this requirement are accompanied by a certificate to that effect issued
by the manufacturer and/or bear the CE mark. Products which do not meet this requirement
may be operated only with the special permission of the BZT (Bundesamt fr Zulassungen
in der Telekommunikation).
I This is a Class A equipment. This equipment may cause harmful interference inresidential areas. In this case, the user may be held liable for taking appropriate
measures and bearing the costs resulting from these measures.
2.5 Notes on Mounting the Rack
For safety reasons, at least two people are required to install the rack-mounted model
because of its weight and size.
When connecting and disconnecting cables, observe the notes in the operating manual
of your system and the comments in the Important Notes chapter in the technical
manual supplied with the rack.
Ensure that the anti-tilt bracket is correctly mounted when you set up the rack.
For safety reasons, no more than one unit may be withdrawn from the rack at any one
time during installation and maintenance work.
If more than one unit is withdrawn from the rack at any one time, there is a danger that
the rack will tilt forward.
The power supply to the rack must be installed by an authorized specialist (electrician).
2.6 Notes on Transportation
I Transport the storage subsystem in its original packaging or in other suitablepackaging which will protect it against shock or impact.
Do not unpack it until all transport maneuvers are completed.
If you need to lift or transport the storage system, ask someone to help you.
-
7/23/2019 Operating Manual-sx60-100 Om 090824
21/112
Important Notes Environmental Protectio
FibreCAT SX Series Operating Manual 2
2.7 Environmental Protection
Environmentally friendly product design and development
This product has been designed in accordance with standards for environmentally friend
product design and development. This means that the designers have taken into accoun
important criteria such as durability, selection of materials, emissions, packaging, the eas
with which the product can be dismantled and the extent to which it can be recycled.
This saves resources and thus reduces the harm done to the environment.
Notes on packaging
Please do not throw away the packaging. We recommend that you do not throw away the
original packaging in case you need it later for transporting.
Notes on labeling plastic housing parts
Please avoid attaching your own labels to plastic housing parts wherever possible, since
this makes it difficult to recycle them.
Take-back, recycling and disposal
For details on returning and reuse of devices and consumables within Europe, refer to th
Returning used devices manual, or contact your Fujitsu branch office/subsidiary or our
recycling centre in Paderborn:
Fujitsu Technology Solutions GmbH
Recycling Center
D-33106 Paderborn
Tel. +49 5251 8180-10
Fax +49 5251 8180-15
The device may not be disposed of with household rubbish. This appliance is
labelled in accordance with European Directive 2002/96/EC concerning used
electrical and electronic appliances (WEEE - waste electrical and electronic
equipment).The guideline determines the framework for the return and recycling of used
appliances as applicable throughout the EU. To return your used device, please
use the return and collection systems available to you. You will find further info
mation on this at www.ts.fujitsu.com/recycling.
-
7/23/2019 Operating Manual-sx60-100 Om 090824
22/112
Site Requirements Important Notes
22 FibreCAT SX Series Operating Manual
2.8 Site Requirements
This chapter provides requirements and guidelines that you must address when preparing
your site for the installation.
CAUTION
When selecting an installation site for the system, choose a location that avoids
excessive heat, direct sunlight, dust, or chemical exposure. These conditions
greatly reduce the systems longevity, and might void your warranty.
2.8.1 Physical Requirements
This section provides dimension and weight specifications, weight and placement guide-
lines, and ventilation requirements.
2.8.1.1 Dimension and Weight Specifications
The floor space at the installation site must be strong enough to support the combined
weight of the rack, controller enclosures, expansion modules, and any additional
equipment. The site should provide sufficient space for installation, operation, and servicing
the enclosures, and also requires sufficient ventilation to allow a free flow of air to all enclo-
sures.
The following table lists enclosure dimensions and weight. Weights are based on an
enclosure having 12 drive modules, 2 controller or expansion modules, and 2 power and
cooling modules installed.
Specification Rackmount
Height 2U 8.76 cm
Width
Chassis excluding mounting ears
Chassis including mounting ears
44.6 cm
48.0 cm
Depth
Chassis
To back of power and cooling module handle
55.37 cm
57.12 cmWeight, controller enclosure (12 drives)
SAS drives
SATA drives
33.1 kg
33.6 kg
Table 13: Dimension and Weight Specification Examples
!
-
7/23/2019 Operating Manual-sx60-100 Om 090824
23/112
Important Notes Site Requiremen
FibreCAT SX Series Operating Manual 2
2.8.1.2 Weight and Placement Guidelines
As you prepare for installation, follow these guidelines:
Ideally, use two people to lift an enclosure. However, one person can safely lift an
enclosure if its weight is reduced by removing the power and cooling modules and driv
modules.
Do not place enclosures in a vertical position. Always install and operate the enclosurein a horizontal orientation.
When installing enclosures in a rack, make sure that any surfaces over which you mig
move the rack can support the weight. To prevent accidents when moving equipmen
especially on sloped loading docks and up ramps to raised floors, ensure you have a
sufficient number of helpers. Remove obstacles such as cables and other objects from
the floor.
To prevent the rack from tipping and to minimize personnel injury in the event of a
seismic occurrence, securely anchor the rack to a wall or other rigid structure that is
attached to both the floor and to the ceiling of the room.
2.8.1.3 Ventilation Requirements
As you prepare for installation, follow these requirements:
Do not block or cover ventilation openings at the front and rear of an enclosure. Neve
place an enclosure near a radiator or heating vent. Failure to follow these guidelines ca
cause overheating and affect the reliability and warranty of the product.
Leave a minimum of 15 cm at the front and back of an enclosure to ensure adequate
airflow for cooling. No cooling clearance is required on the sides, top, or bottom of encl
sures.
Leave enough space in front and in back of an enclosure to allow access to enclosurcomponents for servicing. Removing a component requires a clearance of at least
137 cm in front of and behind the enclosure.
Weight, expansion enclosure (12 drives)
SAS drives
SATA drives
30.8 kg
31.3 kg
Specification Rackmount
Table 13: Dimension and Weight Specification Examples
-
7/23/2019 Operating Manual-sx60-100 Om 090824
24/112
Site Requirements Important Notes
24 FibreCAT SX Series Operating Manual
2.8.2 Environmental Requirements
The following table lists the environmental conditions in which the rackmounted controller
enclosure operates.
2.8.3 Electrical Requirements
This section provides electrical guidelines and site wiring, power, and cabling requirements.
2.8.3.1 Electrical Guidelines
Each enclosure is shipped with two AC power cords that are appropriate for use in a typical
outlet in the destination country. Each power cord should connect one of the power and
cooling modules to an independent, external power source. To ensure power redundancy,
connect the two power cords to two separate circuits; for example, to one commercial circuit
and to one uninterruptable power source (UPS).
Safety status of I/O connections comply with Separated Extra Low Voltage (SELV) require-
ments.
Specification Range
Altitude To 3 km, derate 2 C for every 1 km up to 3 km
Relative Humidity 10% to 90% RH, 27 C max. wet bulb, non-condensing
Temperature 5 C to 40 C, non-condensing
Shock 3.0 g, 11 ms, half-sine
Vibration 0.15 g (vertical); 0.10 g (horizontal), 5 to 500 Hz, swept-sine
Table 14: Environmental Requirements
-
7/23/2019 Operating Manual-sx60-100 Om 090824
25/112
Important Notes Site Requiremen
FibreCAT SX Series Operating Manual 2
As you prepare for installation, follow these guidelines:
The enclosures work with single-phase power systems having an earth ground
connection. To reduce the risk of electric shock, do not plug an enclosure into any othe
type of power system. Contact your facilities manager or a qualified electrician if you arnot sure what type of power is supplied to your building.
Enclosures are shipped with a grounding-type (three-wire) power cord. To reduce the
risk of electric shock, always plug the cord into a grounded power outlet.
Do not use household extension cords with the enclosures. Not all power cords have
the same current ratings. Household extension cords do not have overload protection
and are not meant for use with computer systems.
2.8.3.2 Site Wiring and Power Requirements
Each enclosure has two power and cooling modules for redundancy. If full redundancy is
required, use a separate power source for each module. The AC power supply unit in eac
power and cooling module is auto-ranging and is automatically configured to an input
voltage range from 88264 VAC with an input frequency of 4763 Hz. The power and
cooling modules meet standard voltage requirements for both U.S. and international
operation. The power and cooling modules use standard industrial wiring with line-to-
neutral or line-to-line power connections.
As you prepare for installation, follow these requirements:
All AC mains and supply conductors to power distribution boxes for the rack-mounted
system must be enclosed in a metal conduit or raceway when specified by local,
national, or other applicable government codes and regulations.
Ensure that the voltage and frequency of your power source match the voltage and
frequency inscribed on the equipments electrical rating label.
To ensure redundancy, provide two separate power sources for the enclosures. Thes
power sources must be independent of each other, and each must be controlled by a
separate circuit breaker at the power distribution point.
The system requires voltages within minimum fluctuation. The customer-supplied fac
ities voltage must maintain a voltage with not more than 5 percent fluctuation. The
customer facilities must also provide suitable surge protection.
Site wiring must include an earth ground connection to the AC power source. The
supply conductors and power distribution boxes (or equivalent metal enclosure) musbe grounded at both ends.
-
7/23/2019 Operating Manual-sx60-100 Om 090824
26/112
Site Requirements Important Notes
26 FibreCAT SX Series Operating Manual
Power circuits and associated circuit breakers must provide sufficient power and
overload protection. To prevent possible damage to the AC power distribution boxes and
other components in the rack, use an external, independent power source that is
isolated from large switching loads (such as air conditioning motors, elevator motors,
and factory loads).
2.8.3.3 Cabling Requirements
As you prepare for installation, follow these requirements:
Keep power and interface cables clear of foot traffic. Route cables in locations that
protect the cables from damage.
Route interface cables away from motors and other sources of magnetic or radio
frequency interference.
Stay within the cable length limitations.
2.8.4 Management Host Requirements
A local management host with at least one serial port connection is required for the initial
installation and configuration of a controller enclosure. After you configure one or both of
the controller modules with an Internet Protocol (IP) address, you then use a remote
management host on an Ethernet network to configure, manage, and monitor.
Note
You must use Ethernet cable designated CAT-5 or higher to connect a controller
enclosure to an Ethernet network.
i
-
7/23/2019 Operating Manual-sx60-100 Om 090824
27/112
FibreCAT SX Series Operating Manual 2
3 Hardware, Operating, and IndicatorComponents
This chapter describes the main hardware components and the position and meaning of th
operating and indicator elements at the FibreCAT SX storage system enclosures.
3.1 Controller EnclosureThe FibreCAT SX60 / SX80 / SX88 / SX100 controller enclosure can be connected to Fibr
Channel host bus adapters or switches. The FibreCAT SX80 iSCSI controller enclosure ca
be connected to Ethernet host bus adapters, hubs or switches.
3.1.1 Components
Enclosure Components Quantity
FC or ISCS RAID controller (I/O)
module
1 or 21
1 Air management system drive blanks or I/O blanks must fill empty slots to maintain optimum airflow through th
chassis.
SAS or SATA drive module 212 per enclosure
AC power and cooling module 2 per enclosure
2- or 4-Gbps FC host port with SFP2
or 1 Gbps iSCSI host port
2 The SFPs are part of the controller modules and must not be removed.
2 per controller module (SX60 / SX80 / S88 / SX80 iSCSI)
4 per controller module (SX100)
3-Gbps, 4-lane SAS expansion port 1 per controller module (SX60 / SX80 / S88 / SX80 iSCSI)
2 per controller module (SX100)
RJ-45 Ethernet port (RJ-45) 1 per controller module
CLI port (RS-232 micro-DB9) 1 per controller module
Table 15: Controller Enclosure Components
-
7/23/2019 Operating Manual-sx60-100 Om 090824
28/112
Controller Enclosure Hardware, Operating, and Indicator Components
28 FibreCAT SX Series Operating Manual
3.1.2 Components and Indicators at the Front Side
Figure 1: Components and Indicators on the Front of an Controller Enclosure
LED Color State Description
Enclosure ID Green On Shows the enclosure ID for an enclosure, which enables
you to correlate a physical enclosure with logical views
presented by management software. The enclosure ID for acontroller enclosure is zero (0); the enclosure ID for an
attached expansion enclosure is non-zero.
OK to Remove(drivemodule)
Blue Off The drive module is not prepared for removal.
On The drive module has been removed from any active virtual
disk, spun down, and prepared for removal.
Power/Activity/Fault
(drive module)
Green Off The drive module is not powered on.
On The drive module is operating normally.
Blink The drive module is active and processing I/O or is
performing a media scan.
Yellow Off No fault.
On The drive module has experienced a fault, has failed or is a
member of a critical vdisk.
Blink Physically identifies the drive module.
Unit Locator
White Off Not active.
Blink Physically identifies the enclosure.
Fault/Service Required
Yellow Off No fault.
On An enclosure-level fault has occurred. Service action is
required. The event has been acknowledged but the
problem still needs attention.
Table 16: Controller Enclosure LEDs (Front)
- FRU OK
- Fault/Service Required
- Temperature Fault
- Unit Locator
Status LEDs (top to bottom):
Drive modules with LEDs
(numbered left to right
by row: 03, 47, 811)
Enclosure ID LED
-
7/23/2019 Operating Manual-sx60-100 Om 090824
29/112
Hardware, Operating, and Indicator Components Controller Enclosu
FibreCAT SX Series Operating Manual 2
3.1.3 Ports and Switches at the Back Side
The following figure shows the ports (location: controller module) and the power switch
(location: power and cooling module) at the back of the FibreCAT SX60 / SX80 / SX88
controller enclosure equipped with two FC RAID controllers. The second (lower) controlle
is optional.You will use the ports and the switch during the installation procedure.
Figure 2: FibreCAT SX60 / SX80 / SX88 Controller Enclosure Ports (FC) and Power Switch
The following figure shows the ports (location: controller module) and the power switch
(location: power and cooling module) at the back of the FibreCAT SX80 iSCSI controller
enclosure equipped with two iSCSI controllers. The second (lower) controller is optional.
You will use the ports and the switch during the installation procedure.
FRU OK
Green On The enclosure is powered on with at least one powermodule operating normally.
Off Both power modules are off.
Temperature Fault
Green Off The enclosure temperature is normal.
Yellow On The enclosure temperature is above threshold.
LED Color State Description
Table 16: Controller Enclosure LEDs (Front)
Power switch
FC ports Expansion portCLI port Ethernet management port
-
7/23/2019 Operating Manual-sx60-100 Om 090824
30/112
Controller Enclosure Hardware, Operating, and Indicator Components
30 FibreCAT SX Series Operating Manual
Figure 3: FibreCAT SX80 iSCSI Controller Enclosure Ports (FC) and Power Switch
The following figure shows the ports (location: controller module) and the power switch
(location: power and cooling module) at the back of the FibreCAT SX100 controller
enclosure equipped with two FC RAID controllers. The second (lower) controller is
optional.You will use the ports and the switch during the installation procedure.
Figure 4: FibreCAT SX100 Controller Enclosure Ports (FC) and Power Switch
Port/Switch Description
Power switch Toggle, where | is On and O is Off.
FC/Ethernet
ports
4-Gbps FC or 1-Gbps iSCSI ports used to connect to data hosts. Each FC port
contains an SFP1transceiver. Host port 0 and 1 connect to host channel 0 and 1,
respectively. The FibreCAT SX100 model has four host ports.
CLI port Micro-DB9 port used to connect the controller module to a local management host
using RS-232 communication for out-of-band configuration and management.
Table 17: Controller Enclosure Ports and Switches (Back)
Power switch
Ethernet ports Expansion portCLI port Ethernet management port
Power switch
FC ports Expansion portsCLI port Ethernet management port
-
7/23/2019 Operating Manual-sx60-100 Om 090824
31/112
Hardware, Operating, and Indicator Components Controller Enclosu
FibreCAT SX Series Operating Manual 3
3.1.4 Indicators at the Back Side
The following figure shows the LEDs at the back of the controller enclosure (FibreCAT SX6
/ SX80 / SX88 as example) equipped with two FC RAID controllers. The second (lower)
controller is optional. You will use the LEDs during the installation procedure.
Figure 5: FibreCAT SX60 / SX80 / SX88 Controller Enclosure (FC) LEDs
Ethernetmanagement
port
10/100BASE-T Ethernet port used for TCP/IP-based out-of-band management othe RAID controller. An internal Ethernet device provides standard 10 Mbit/secon
and 100 Mbit/second full-duplex connectivity.Expansion port 3-Gbps, 4-lane (12 Gbps total) table-routed egress port used to connect SAS
expansion enclosures.
1 The SFPs are part of the controller modules and must not be removed (SFP = Small Form-factor Pluggable)
LED (Location: Power
and Cooling Module)
Color State Description
AC Power Good Green Off AC power is off or input voltage is below the minimum
threshold.
On AC power is on and input voltage is normal.
DC Voltage/Fan Fault/
Service Required
Yellow Off DC output voltage is normal.
On DC output voltage is out of range or a fan is operatingbelow the minimum required RPM.
Table 18: Controller Enclosure LEDs (Back, Power and Cooling Module)
Port/Switch Description
Table 17: Controller Enclosure Ports and Switches (Back)
AC Power Good
Service RequiredDC Voltage/Fan Fault/
Host link speed
Host link status Cache status
Host activity Expansion port stat
Unit Locator
OK to Remove Fault/Service Required
FRU OK Ethernet activity
Ethernet link status
-
7/23/2019 Operating Manual-sx60-100 Om 090824
32/112
Controller Enclosure Hardware, Operating, and Indicator Components
32 FibreCAT SX Series Operating Manual
LED (Location:
Controller Module)
Color State Description
Host link status (FC only) Green Off The port is empty or the link is down.
On The port link is up and connected.
Host link speed (FC only) Green Off The data transfer rate is 2 Gbps.
On The data transfer rate is 4 Gbps.
Unit Locator
White Off Not active.
Blink Physically identifies the controller module.
OK to Remove
Blue Off The controller module is not prepared for removal.
On The controller module can be removed.
Fault/ServiceRequired
Yellow On A fault has been detected or a service action is required.
Blink Indicates a hardware-controlled power up or a cacheflush or restore error.
FRU OK
Green Off Controller module is not OK.
On Controller module is operating normally.
Blink System is booting.
Cache status Green Off Cache is clean (contains no unwritten data).
On Cache is dirty (contains unwritten data) and operation isnormal.
Blink A Compact Flash flush or cache self-refresh is in
progress.
Host activity Green Off The host ports have no I/O activity.
Blink At least one host ports has I/O activity.
Ethernet link status Green Off The Ethernet port is not connected or the link is down.
On The Ethernet link is up.
Ethernet activity Green Off The Ethernet link has no I/O activity.
Blink The Ethernet link has I/O activity.
Expansion port status Green Off The port is empty or the link is down.
On The port link is up and connected.
Table 19: Controller Enclosure LEDs (Back, Controller Module)
-
7/23/2019 Operating Manual-sx60-100 Om 090824
33/112
Hardware, Operating, and Indicator Components Expansion Enclosu
FibreCAT SX Series Operating Manual 3
3.2 Expansion Enclosure
The FibreCAT SX expansion enclosure can be connected to a FibreCAT SX controller
enclosure to provide additional disk storage capacity.
3.2.1 Components.
3.2.2 Components and Indicators at the Front Side
The components and indicators at the front of an expansion enclosure are the same as a
a controller enclosure (see page 28).
3.2.3 Ports and Switches at the Back Side
The following figure shows the ports (location: expansion module) and the power switch
(location: power and cooling module) at the back of the expansion enclosure equipped wit
two SAS expansion modules. The second (lower) module is optional.You will use the port
and the switch during the installation procedure.
Description Quantity
SAS expansion module 1 or 21
1 Air management system drive blanks or I/O blanks must fill empty slots to maintain
optimum airflow through the chassis.
SAS or SATA drive module 212 per enclosure
AC power and cooling module 2 per enclosure
3-Gbps, 4-lane SAS In port 1 per expansion module
3-Gbps, 4-lane SAS Out port 1 per expansion moduleTable 20: Expansion Enclosure Components
-
7/23/2019 Operating Manual-sx60-100 Om 090824
34/112
Expansion Enclosure Hardware, Operating, and Indicator Components
34 FibreCAT SX Series Operating Manual
Figure 6: Expansion Enclosure Ports and Power Switch
Port/Switch DescriptionPower switch Toggle, where | is On and O is Off.
SAS In port 3-Gbps, 4-lane (12 Gbps total) subtractive ingress port used to connect to a
controller enclosure.
SAS Out port 3-Gbps, 4-lane (12 Gbps total) table-routed egress port used to connect to another
expansion enclosure.
Table 21: Expansion Enclosure Ports and Switches (Back)
Power switch
SAS In port SAS Out port
-
7/23/2019 Operating Manual-sx60-100 Om 090824
35/112
Hardware, Operating, and Indicator Components Expansion Enclosu
FibreCAT SX Series Operating Manual 3
3.2.4 Indicators at the Back Side
The following figure shows the LEDs at the back of the expansion enclosure equipped wit
two SAS expansion modules. The second (lower) module is optional. You will use the LED
during the installation procedure.
Figure 7: Expansion Enclosure LEDs
LED (Location: Power
and Cooling Module)
Color State Description
AC Power Good Green Off AC power is off or input voltage is below the minimumthreshold.
On AC power is on and input voltage is normal.
DC Voltage/Fan Fault/Service Required
Yellow Off DC output voltage is normal.
On DC output voltage is out of range or a fan is operating
below the minimum required RPM.
Table 22: Expansion Enclosure LEDs (Back, Power and Cooling Module)
LED (Location:
Expansion Module)
Color State Description
SAS In port status Green Off The port is empty or the link is down.
On The port link is up and connected.
SAS Out port status Green Off The port is empty or the link is down.
On The port link is up and connected.
Table 23: Expansion Enclosure LEDs (Back, Expansion Module)
AC Power Good
Service Required
DC Voltage/Fan Fault/
Unit Locator
OK to Remove Fault/Service Required
FRU OK
SAS In port status SAS Out port status
-
7/23/2019 Operating Manual-sx60-100 Om 090824
36/112
Expansion Enclosure Hardware, Operating, and Indicator Components
36 FibreCAT SX Series Operating Manual
Unit Locator
White Off Not active.
Blink Physically identifies the expansion module.
OK to Remove
Blue Off Not implemented.
Fault/ServiceRequired
Yellow On A fault has been detected or a service action is required.
Blink Indicates a hardware-controlled power up or a cacheflush or restore error.
FRU OK
Green Off Expansion module is not OK.
On Expansion module is operating normally.
Blink System is booting.
LED (Location:
Expansion Module)
Color State Description
Table 23: Expansion Enclosure LEDs (Back, Expansion Module)
-
7/23/2019 Operating Manual-sx60-100 Om 090824
37/112
FibreCAT SX Series Operating Manual 3
4 Connecting Hosts / Configurations
This chapter describes the FibreCAT SX system cable connections for hosts and shows
typical configurations.
4.1 Connecting Remote Management Hosts
The management host directly manages systems out-of-band over a network. This sectiodescribes how to connect the Ethernet cables and power cords to the management host
1. Locate the Ethernet ports for controller A and controller B at the back of the controlle
enclosure.
2. Connect an Ethernet cable to each Ethernet port.
3. Connect the other end of each Ethernet cable to a network that your management ho
can access (preferably on the same subnet).
4.2 Installing the SCSI Enclosures Services Driver
NOTE
This section applies to Microsoft Windows hosts only.
Installing the SCSI Enclosure Services (SES) driver prevents Microsoft Windows hosts fro
displaying the Found New Hardware Wizard when the storage system is discovered.
1. In a web browser, go to
http://support.ts.fujitsu.com/com/support/downloads.html and download the SCSI
enclosure device driver for FibreCAT SX to a network location that the data host can
access.
2. Extract the package contents to a temporary folder on the host.
3. In that folder, double-click Setup.exe to install the driver.
4. Click Finish.
The driver is installed.
i
http://support.ts.fujitsu.com/com/support/downloads.htmlhttp://support.ts.fujitsu.com/com/support/downloads.html -
7/23/2019 Operating Manual-sx60-100 Om 090824
38/112
Connecting Direct Attached iSCSI Configurations Connecting Hosts / Configurations
38 FibreCAT SX Series Operating Manual
4.3 Connecting Direct Attached iSCSI Configurations
4.3.1 Single Controller FibreCAT SX80 iSCSI With One HostA single-controller configuration is supported but provides no redundancy in the event that
the controller fails. Each data host has one iSCSI port connected to the controller module.
If the controller fails, the host loses access to the volume LUNs.
Single-Controller, Direct Attach Connection to a Single Data Host shows the direct attach
configuration for a single data host
Figure 8: Single-Controller, Direct Attach Connection to a Single Data Host (iSCSI)
The FibreCAT SX80 iSCSI Storage Systems was designed as a fully redundant dual
controller storage array for iSCSI systems. The storage system alternately assigns virtual
disks between the two controllers to support automatic load balancing. It is currently
available as a non-redundant single controller storage system as an entry level option.
When the FibreCAT SX80 iSCSI Storage System has a single controller, every other virtual
disk created will be owned by the non-existent second controller, regardless of the
ownership specified when creating the virtual disk - any storage assigned to the missing
controller is treated as "failed-over" to the existing controller. This choice allows for trans-parent upgrade to a dual controller system in the future. In order for the virtual disks
assigned to the non-existent controller to be visible, the host needs to establish logins to
both iSCSI targets. The IP addresses of the non-existent controller (target) need to be
configured in the storage system. The connected hosts then need to establish iSCSI
sessions (logins) to one or both targets to access the volumes on those virtual disks.
-
7/23/2019 Operating Manual-sx60-100 Om 090824
39/112
Connecting Hosts / Configurations Host Interface Speed for FibreCAT SX (FC
FibreCAT SX Series Operating Manual 3
For example, if you create 6 virtual disks, then the second, fourth and sixth virtual disks
would be owned by the non-existent second controller. To present volumes created on
these virtual disks to a host, you must assign IP addresses to the same ports on the non
existent controller as ports that are used on the existing controller. The address assigned
to the port of the non-existent controller must be in the same network as the same port othe existing controller. For example, if controller A has the following configuration:
Controller A
Port/Channel: 0 1
IP: 192.168.144.1 10.0.0.1
Netmask: 255.255.255.0 255.0.0.0
You should then set the IP address of the ports on the controller that is not installed to
reserve addresses in the same subnets so those hosts can see the volumes through the
controller, as shown below:
Controller B (currently not installed)
Port/Channel: 0 1
IP: 192.168.144.18 10.0.0.22
Netmask: 255.255.255.0 255.0.0.0
Finally, include these addresses in the iSCSI initiator configuration the same as you woul
the IP addresses of the existing controller.
If you follow this process, all of the volumes created on the FibreCAT SX80 iSCSI Storag
System will be visible through the existing controller host ports. When you are ready to
upgrade to a dual controller system, simply install the second controller with Ethernet
cables pre-attached and all the work will be done automatically by the storage system to
move those volumes to the new controller.
Configuration Rules
Fixed speed for all ports
4.4 Host Interface Speed for FibreCAT SX (FC)
NOTE
The following restriction applies to FibreCAT SX60 / SX80 in direct attached confi
urations:
If your Host Interface Module (HIM) is Model 0(or you have a mixed mode of HIM0 and 1 in a dual controller FibreCAT controller enclosure), for FibreCAT SX60 /
SX80 in directconnect mode 2 Gbit FC speed is supported only.
If both HIMs in your controller enclosure are Model 1 (or you have only a single controlle
FibreCAT SX and it is Model 1), in direct host connect mode up to 4 Gbit FC speed is
supported for FibreCAT SX60 / SX80.
i
-
7/23/2019 Operating Manual-sx60-100 Om 090824
40/112
Host Interface Speed for FibreCAT SX (FC) Connecting Hosts / Configurations
40 FibreCAT SX Series Operating Manual
For FibreCAT SX88 / SX100, in direct host connect mode always up to 4 Gbit FC speed is
supported.
In switchattached mode, for FibreCAT SX60 / SX80 / SX88 / SX100 up to 4 Gbit FC speed
is supported always (no restriction with any HIM Model).If you have a direct attached configuration with FibreCAT SX60 / SX80, you should find out
the HIM Model (0 or 1) of your controller(s) via FibreCAT SX Managers Web Based
Interface:
1. Open FibreCAT SX Managers Web Based Interface.
2. Login asmonitor ormanage user.
3. InMONITOR STATUSmenu, click the link advanced settings (see screenshots below).
Here you can find out the HIM Model of your controller module(s):
Figure 9: Detecting the HIM Model With FibreCAT SX Managers WBI (Example With Two HIM Models 0)
-
7/23/2019 Operating Manual-sx60-100 Om 090824
41/112
Connecting Hosts / Configurations Connecting Direct Attached FC Configuration
FibreCAT SX Series Operating Manual 4
Figure 10: Detecting the HIM Revision With FibreCAT SX Managers WBI (Example With Two HIM Models 1)
4.5 Connecting Direct Attached FC Configurations
This section explains how to connect data hosts to access the controller enclosure directl
You will need fibre optic cables of the proper length to connect your data host to the storag
system.
The FibreCAT SX60 / SX80 / SX88 controller enclosure equipped with two controllers ha
four FC connections, two per controller. The FibreCAT SX100 controller enclosure equippe
with two controllers has eight FC connections, four per controller. To maintain redundanc
connect one data host to both Controller A and Controller B.
1. Locate the host ports at the back of the controller enclosure.
2. Connect a fiber optic cable to each host port on controller A and controller B.
V CAUTION!Fiber optic cables are fragile. Do not bend, twist, fold, pinch, or step on the fibe
optic cables. Doing so can degrade performance or cause data loss.
3. Connect the other end of each fiber optic cable to the HBAs as shown in the followin
figures.
-
7/23/2019 Operating Manual-sx60-100 Om 090824
42/112
Connecting Direct Attached FC Configurations Connecting Hosts / Configurations
42 FibreCAT SX Series Operating Manual
4.5.1 FibreCAT SX60 / SX80 / SX88 With One Dual Port Host
The cabling examples show a high-availability controller and path failover configuration.
This configuration requires host port interconnect circuitry between controller modules to
be set toInterconnectedas described in Configuring Controller Enclosure Host Ports (FC)on page 78. For path failover this configuration requires a host-based multipathing software.
The controller enclosure is equipped with two FC RAID controllers and the host have two
FC HBAs each.
Figure 11: Minimal Connection to a Single Data Host
Configuration Rules
Restrictions: not for VMware
FC-Topology: Arbitrated Loop (FC-AL)
FC Speed: max. 4Gbit/s
(note Host Interface Speed for FibreCAT SX (FC) on page 39)
Host Port Interconnect: Interconnected
Path-Failover Software: FTS DDM V5; native MPIO (DSM); FTS Multipath V 5,
native DM-MP (RedHat, SuSE)
Port interconnects:
interconnected by FibreCAT SX Manager
-
7/23/2019 Operating Manual-sx60-100 Om 090824
43/112
Connecting Hosts / Configurations Connecting Direct Attached FC Configuration
FibreCAT SX Series Operating Manual 4
4.5.2 FibreCAT SX60 / SX80 / SX88 With Two Dual Port Hosts
The following figure shows the preferred high-availability controller and path redundant
configuration. This configuration requires that host port interconnects are set to Intercon-
nectedas described in Configuring Controller Enclosure Host Ports (FC) on page 78. Thconfiguration also requires host-based multipathing software. For failover behavior, see
Configurations on page 79.
Figure 12: High-Availability, Dual-Controller, Direct Attached Connection to Dual Data Hosts for Windows and
Linux (no VMware support)
Configuration Rules
Restrictions: not for VMware
FC-Topology: Arbitrated Loop (FC-AL)
FC Speed: max. 4Gbit/s(note Host Interface Speed for FibreCAT SX (FC) on page 39)
Host Port Interconnect: Interconnected
Path-Failover Software: FTS DDM V5; native MPIO (DSM); FTS Multipath V 5,
native DM-MP (RedHat, SuSE)
A + B LUNs A + B LUNs
A + B LUNs A + B LUNs
http://s60_80.pdf/http://s60_80.pdf/ -
7/23/2019 Operating Manual-sx60-100 Om 090824
44/112
Connecting Direct Attached FC Configurations Connecting Hosts / Configurations
44 FibreCAT SX Series Operating Manual
4.5.2.1 Controller Failover Scenario
Figure 13: Direct Attached FibreCAT SX (Controller Failover Scenario)
In an active-active configuration, failover is the act of temporarily transferring ownership of
controller resources from a failed controller to a surviving controller. The resources include
virtual disks, cache data, host ID information, and LUNs and WWNs. In this scenario host
A and host B see all resources via controller A.
A + B LUNs
A + B LUNs
FAILED
-
7/23/2019 Operating Manual-sx60-100 Om 090824
45/112
Connecting Hosts / Configurations Connecting Direct Attached FC Configuration
FibreCAT SX Series Operating Manual 4
4.5.2.2 Path Failover Scenario
Figure 14: Direct Attached FibreCAT SX (Path Failover Scenario)
In scenario of path-failover, host A sees his B-LUNs via the host interconnect line. The filte
driver (multipath software) generates the B-LUN I/Os across the other HBA.
A + B LUNs
A + B LUNs A + B LUNs
-
7/23/2019 Operating Manual-sx60-100 Om 090824
46/112
Connecting Direct Attached FC Configurations Connecting Hosts / Configurations
46 FibreCAT SX Series Operating Manual
4.5.3 FibreCAT SX60 / SX80 / SX88 With Two Dual Port Hosts for HighPerformance
The following figure shows a non-redundant path-failover configuration that can be used
when high performance is more important than high availability. This configuration requiresthe host port interconnect circuitry to be be set to Straight-through, which it is by default.
Figure 15: High-Performance, Dual-Controller, Direct Attached Connection to Dual Data Hosts (no Solaris
Support)
Configuration Rules
Restrictions: not for Solaris and not for VMware
FC-Topology: Arbitrated Loop (FC-AL)
FC Speed: max. 4Gbit/s (note Host Interface Speed for FibreCAT SX (FC)
on page 39)
Host Port Interconnect: Straight-through
Path-Failover Software: FTS DDM V5; native MPIO (DSM); FTS Multipath V 5
A LUNs B LUNs
A LUNs B LUNs
-
7/23/2019 Operating Manual-sx60-100 Om 090824
47/112
Connecting Hosts / Configurations Connecting Direct Attached FC Configuration
FibreCAT SX Series Operating Manual 4
4.5.4 FibreCAT SX100 With Four Dual-Port Hosts
Figure 16: Four Dual-Port Data Hosts with FibreCAT SX100
2370, 2278 2070, 2178
2370, 2278 2070, 2178
2270, 2378 2078, 2170
2270, 2378 2078, 2170
-
7/23/2019 Operating Manual-sx60-100 Om 090824
48/112
Connecting Direct Attached FC Configurations Connecting Hosts / Configurations
48 FibreCAT SX Series Operating Manual
This figure shows the optimized connectivity for a high-availability, dual-controller, direct
attached connection to four dual-port data hosts. To ensure failover fault tolerance, each
dual port host must be connected to each controller. Connecting one host port to Port 0 or
Port 1 and the other to Port 2 or Port 3 on the other controller provides the most efficient
internal path balancing in each controller.
Configuration Rules
Usage Clustered servers, direct connect to storage, classroom applications, classroom file
server
Advantage
Benefits of fault tolerance of dual-controller and clustered servers
Example business
Educational facility; small tech business
Topology
Loop mode
HBA settings
fixed speed 2/4Gbit
Link time out 60 sec
node time out 60 sec
Queue depth (see release notes)
SW MPIO SW
Storage settings
host port interconnect:Interconnected
In this configuration, all hosts have redundant connections to volumes that are associated
with each of the controllers. If a controller fails, the hosts maintain access to all of the
volumes through the hosts ports on the surviving controller.
-
7/23/2019 Operating Manual-sx60-100 Om 090824
49/112
Connecting Hosts / Configurations Connecting Direct Attached FC Configuration
FibreCAT SX Series Operating Manual 4
4.5.4.1 Controller Failover Scenario
Figure 17: Four Dual-Port Data Hosts with FibreCAT SX100 and Failed Controller
2370, 2278 2070, 2178
2370, 2278 2070, 2178
2270, 2378 2078, 2170
2170, 2078 2078, 2170
FAILED
-
7/23/2019 Operating Manual-sx60-100 Om 090824
50/112
Connecting Switch Attached iSCSI Configurations Connecting Hosts / Configurations
50 FibreCAT SX Series Operating Manual
4.6 Connecting Switch Attached iSCSI Configurations
4.6.1 FibreCAT SX80 iSCSI With Two Dual Port Hosts and Two SwitchesThe high-availability configuration requires two Gigabit Ethernet (GbE) switches, as shown
in the following figure. During active-active operation, both controllers' mapped volumes are
visible to both data hosts.
Figure 18: iSCSI Storage Presentation During Normal, Active-Active Operation
A & B volumes
A & B volumes
B volumes, B0 IP
A volumes, A0 IP
B volumes, B1 IP
A volumes, A1 IP
-
7/23/2019 Operating Manual-sx60-100 Om 090824
51/112
Connecting Hosts / Configurations Connecting Switch Attached iSCSI Configuration
FibreCAT SX Series Operating Manual 5
A dual-controller FibreCAT SX80 iSCSI storage system uses port 0 of each controller as
one failover pair and port 1 of each controller as a second failover pair. If one controller fail
all mapped volumes remain visible to all hosts. Dual IP-address technology is used in the
failed over state, and is largely transparent to the host system. However, for complete fau
tolerance, host-based path failover software is recommended.
Configuration Rules
Fixed speed for all ports
4.6.1.1 Controller Failover Scenario
The following figure shows an example of storage presentation during failover of
controller B.
Figure 19: iSCSI Storage Presentation During Failover
A & B volumes
A & B volumes
A & B volumes, A0 & B0 IPs A & B volumes, A1 & B1 IPs
-
7/23/2019 Operating Manual-sx60-100 Om 090824
52/112
Connecting Switch Attached FC Configurations Connecting Hosts / Configurations
52 FibreCAT SX Series Operating Manual
Single controller mode is supported in both direct attached and switch attached configu-
ration. In single controller mode the system is set to a failed over state to support a future
upgrade to dual controller system. When configuring a single controller system you will
need to assign ghost host IP configuration to the system. This will ensure that when an
additional controller is inserted no additional configuration is required.
NOTE
Ensure that when configuring a single controller system you assign a host port IP
address to both the active controller and the host B controller.
4.7 Connecting Switch Attached FC Configurations
This section explains how to connect data hosts to access the controller enclosure through
one or more external FC switches.
You will need fiber optic cables of the proper length to connect your data host to the switch,
and the switch to the storage system.
4.7.1 FibreCAT SX60 / SX80 / SX88 With One Switch and One Dual Port Host
1. Locate the host ports at the back of the controller enclosure.
2. Connect a fiber optic cable to each host port on controller A and controller B.
V CAUTION!
Fiber optic cables are fragile. Do not bend, twist, fold, pinch, or step on the fiberoptic cables. Doing so can degrade performance or cause data loss.
3. Connect the other end of each cable to a switch port. Refer to Figure 20for configu-
ration options.
4. Using fiber optic cables connect the switch to two FC HBA ports as shown in the
following figures.
i
-
7/23/2019 Operating Manual-sx60-100 Om 090824
53/112
Connecting Hosts / Configurations Connecting Switch Attached FC Configuration
FibreCAT SX Series Operating Manual 5
The following figure shows a redundant connection through a single switch to a single dat
host with two HBA ports. This configuration requires that host port interconnects are set t
Straight-through. It also requires host-based multipathing software.
Figure 20: Redundant Connection Through a Single Switch to a Single Data Host
NOTE
The FC switch must be configured according to port zoning rules (only one initiato
and one target per zone) and with fixed speed and topology settings.
A + B LUNs A + B LUNs
i
-
7/23/2019 Operating Manual-sx60-100 Om 090824
54/112
Connecting Switch Attached FC Configurations Connecting Hosts / Configurations
54 FibreCAT SX Series Operating Manual
4.7.2 FibreCAT SX60 / SX80 / SX88 With Two Switches and One Dual PortHost
1. Locate the host ports at the back of the controller enclosure.
2. For switch A: Connect fiber optic cables to host port 0 on controller A and host port 1
on controller B. Then connect the other ends of the cables to the switch.
3. For switch B: Connect fiber optic cables to host port 1 on controller A and host port 0
on controller B. Then connect the other ends of the cables to the switch.
V CAUTION!Fiber optic cables are fragile. Do not bend, twist, fold, pinch, or step on the fiber
optic cables. Doing so can degrade performance or cause data loss.
4. Using fiber optic cables connect each of the two switches to FC HBAs on the host as
shown in the following figure.
This configuration requires host port interconnect circuitry between controller modules tobe set to Straight-through. The cabling examples show a controller and path high-availability
configuration. For path failover this configuration requires a host-based multipathing
software. The controller enclosure is equipped with two FC RAID controllers and the host
has two FC HBAs.
Figure 21: Redundant, High-Availability Connection Through Switches to Dual Data Hosts
A B
A B
A+B LUNs
A+B LUNs
MMF
-
7/23/2019 Operating Manual-sx60-100 Om 090824
55/112
Connecting Hosts / Configurations Connecting Switch Attached FC Configuration
FibreCAT SX Series Operating Manual 5
NOTE
The FC switch must be configured according to port zoning rules (only one initiato
and one target per zone) and with fixed speed and topology settings.
Configuration RulesRestrictions: with Solaris not for FibreCAT SX60
FC-Topology: Arbitrated Loop (FC-AL)
FC Speed: 2 / 4 Gbit/s
Host Port Interconnect: Straight-through
Max. Member in Switch Zone: only 1 initiator and 1 target per zone
Path-Failover Software Linux: native DM-MP (RedHat, SuSE)
Path-Failover Software Windows: FTS DDM V5, native MPIO (DSM), FTS Multipath V
Path-Failover Software VMware: native MP
4.7.2.1 Configuration Rules for VMware ESX Server 3.0.0 and 3.0.1
Figure 20above shows the configuration.
Only switch configuration supported.
Use port zoning and not WWN zoning on the switches.
Adjust the port topology on the switch: F-Port for server, L-Port for storage.
Adjust the link speed on the switch ports.
FibreCAT SX Configuration:
Host Port Configuration Link Speed: 4 Gbit/s or 2 Gbit/s (depending on HBA)
Internal Host Port Interconnect: Straight-through
i
-
7/23/2019 Operating Manual-sx60-100 Om 090824
56/112
Connecting Switch Attached FC Configurations Connecting Hosts / Configurations
56 FibreCAT SX Series Operating Manual
4.7.3 FibreCAT SX60 / SX80 / SX88 With Two Switches and Two Dual PortHosts
For high availability, two data hosts can be connected through two switches to a dual-
controller storage system. The controller host port interconnects must be set to Straight-
thrroughand host-based multipathing software is not required.
Figure 22: Switch Attached Configuration with Two Switches and Two Hosts
NOTE
The FC switch must be configured according to port zoning rules (only one initiator
and one target per zone) and with fixed speed and topology settings.
i
-
7/23/2019 Operating Manual-sx60-100 Om 090824
57/112
Connecting Hosts / Configurations Connecting Switch Attached FC Configuration
FibreCAT SX Series Operating Manual 5
Configuration Rules
Restrictions: with Solaris not for FibreCAT SX60
FC-Topology: Arbitrated Loop (FC-AL)
FC Speed: 2 / 4 Gbit/s
Host Port Interconnect: Straight-throughMax. Member in Switch Zone: only 1 initiator and 1 target per zone
Path-Failover Software Linux: native DM-MP (RedHat, SuSE)
Path-Failover Software Windows: FTS DDM V5, native MPIO (DSM), FTS Multipath V
Path-Failover Software VMware: native MP
-
7/23/2019 Operating Manual-sx60-100 Om 090824
58/112
Connecting Switch Attached FC Configurations Connecting Hosts / Configurations
58 FibreCAT SX Series Operating Manual
4.7.4 FibreCAT SX100 With One Switch and Two Dual-Port Hosts
Figure 23: Two Dual-Port Data Hosts with FibreCAT SX100 and a Switch for High Availability
NOTEThe FC switch must be configured according to port zoning rules (only one initiator
and one target per zone) and with fixed speed and topology settings.i
-
7/23/2019 Operating Manual-sx60-100 Om 090824
59/112
Connecting Hosts / Configurations Supported HBAs for Solaris (SPARC
FibreCAT SX Series Operating Manual 5
Configuration Rules
FC-Topology: Arbitrated Loop (FC-AL)
FC Speed: 2 / 4 Gbit/s
Host Port Interconnect: Straight-through
Max. Member in Switch Zone: only 1 initiator and 1 target per zonePath-Failover Software Linux: native DM-MP (RedHat, SuSE)
Path-Failover Software Windows: FTS DDM V5, native MPIO (DSM), FTSC Multipath V
Path-Failover Software VMware: native MP
4.8 Supported HBAs for Solaris (SPARC)
For the latest released Host Bus Adapters, the latest released drivers and their settings,
please refer to http://www.ts.fujitsu.com/support/manuals.html . Select your
product (STORAGE / FibreCAT / FibreCAT SX ...). Here you can find the documentReleased Host Bus Adapters; Driver Settings and FW-Versions for FibreCAT SX ....
http://www.ts.fujitsu.com/support/manuals.htmlhttp://www.ts.fujitsu.com/support/manuals.html -
7/23/2019 Operating Manual-sx60-100 Om 090824
60/112
-
7/23/2019 Operating Manual-sx60-100 Om 090824
61/112
FibreCAT SX Series Operating Manual 6
5 Installing Enclosures
This chapter describes the process of installing FibreCAT SX enclosures in a
PRIMECENTER rack or in a standard 19-inch EIA rack cabinet.
The installation procedures in this chapter require the following items:
#2 Phillips screwdriver
Standard screwdriver
Allen wrench (provided; used with 6-mm screws and #12-24 x 3/8-inch socketheadscrews)
Antistatic protection devices
V CAUTION!Be careful if using a power tool; it could strip or damage connections.
V CAUTION!Electrostatic discharge can damage sensitive components. be sure you are
properly grounded before touching a static-sensitive component or assembly.
5.1 Safety Precautions
For your protection, observe the following safety precautions when setting up your
equipment:
Follow all cautions and instructions marked on the equipment.
Ensure that the voltage and frequency of your power source match the voltage and
frequency inscribed on the equipments electrical rating label.
Never push objects of any kind through openings in the equipment. Dangerous voltage
may be present. Conductive foreign objects could produce a short circuit that could
cause fire, electric shock, or damage to your equipment.
I Do not make mechanical or electrical modifications to the product. The vendor not responsible for the safety or regulatory compliance of a modified product.
-
7/23/2019 Operating Manual-sx60-100 Om 090824
62/112
Unpacking an Enclosure and Verifying its Contents Installing Enclosures
62 FibreCAT SX Series Operating Manual
5.2 Unpacking an Enclosure and Verifying its Contents
This section provides a list of contents in an enclosure package.
V CAUTION!Two people are needed to lift and move the enclosure. Use care to avoid injury. An
enclosure with all drives installed can weigh 33.6 kg. Do not lift the front of the
enclosure; this can cause damage to the drives.
1. Unpack the enclosure.
2. Check the contents of the enclosure and box for the items listed in the following table.
Item Quantity
Enclosure ordered1:
Controller enclosure
Expansion enclosure
1 The enclosure includes 1 or 2 controller or expansion modules, as ordered.
1
SFP2transceivers
2 The SFPs are part of the controller modules and must not be removed.
1 per host port
7.5 m shielded CAT-5 Ethernet Crossover cable
(controller enclosure)
1 with second controller module
5 m serial cable, RS-232 micro-DB9 (controller
enclosure)
1 per controller module
0.5 m SAS-to-SAS cascading cable (expansion
enclosure)
1 per expansion module
2.5 m power cord 2 per enclosure
Rackmount kit 1 per enclosure
Safety manual 1
Purchased options. These options are ordered at th