One SerieS Smart tranSmitter-Switch fOr preSSure and ... · One SerieS Smart tranSmitter-Switch fOr...

16
O N E S E R I E S 1 X- B - 0 4 ONE SERIES SMART TRANSMITTER-SWITCH FOR PRESSURE AND TEMPERATURE MONITORING RoHS compliant LEADERS IN SAFETY, ALARM & SHUTDOWN DUAL SEAL CERTIFIED NAMUR standard and HART®-enabled smart transmitter + programmable switch for process monitoring, alarm and shutdown Switch-only models replace mechanical switches for cost-effective upgrades using existing wires Display and keypad provide easy, fast and secure field programming while in service Programmable set point and deadband provides accurate and fast cycling for rotating equipment Worldwide hazardous location approvals included:

Transcript of One SerieS Smart tranSmitter-Switch fOr preSSure and ... · One SerieS Smart tranSmitter-Switch fOr...

o n e S e r i e S 1 X - B - 0 4

One SerieS Smart tranSmitter-Switch fOr preSSure and temperature mOnitOring

RoHScompliant

LEADERS IN SAFETY, ALARM & SHUTDOWN

DUAL SEALCERTIFIED

• namur standard and hart®-enabled smart transmitter + programmable switch for process monitoring, alarm and shutdown

• Switch-only models replace mechanical switches for cost-effective upgrades using existing wires

• display and keypad provide easy, fast and secure field programming while in service

• programmable set point and deadband provides accurate and fast cycling for rotating equipment

• worldwide hazardous location approvals included:

2 w w w . u e o n l i n e . c o m One Series 1X-B-04

overview

United Electric Controls Company (UE) is recognized for high-quality products with innovative product design, and the One Series carries this 85-year tradition well beyond the electromechanical switches for which UE is known. UE's One Series line of programmable electronic pressure and temperature products sets new standards for quality, reliability, and SIL capability.

The One Series provides explosion (flame)-proof, intrinsically safe and non-incentive models that monitor gage pressure, differential pressure or temperature. An advanced low-power microcontroller provides four SMART model platforms –

1. a NAMUR NE 43 standard and HART-enabled transmitter (1XTX00),

2. two discrete (digital input)-powered electronic switches (1XSW) that operate on the existing application’s 2 wires,

3. a transmitter-switch hybrid with two independent and programmable solid state relays (1XTXSW)

4. and a 4-wire switch that provides high-power switching for local control of loads directly and at the point of measure.

With no moving parts, these versatile instruments can be used in a wide variety of safety control, alarm and interlock applications (SCAI).

UE's One Series is your best choice for tough applications with high cycle rates, severe shock or high vibration. For plant upgrades, the versatile powering options - analog loop, discrete input powered (VDC or VAC) and externally powered models offer options for soft or high capacity SPST alarm, trip or emergency shutdown.

With its integral digital display, the "fit for service" One Series effectively does the job of multiple instruments: transmitter, gauge, process switch, or trip alarm. The embedded logic and high diagnostic coverage means the One Series is a safer, smarter and less complex device than other sensor alternatives, delivering more value for price.

Companies should consider adding United Electric's advanced technology One Series product line to their Acceptable Manufacturers List (AML) in appropriate pressure and temperature commodity classes such as Pressure/Temperature Indicating Transmitter, Digital Indicating Switch, and hybrid Transmitter-Switch.

AWARD-WINNING DESIGN

The One Series’ innovative design is recognized worldwide as the recipient of 3 prestigious engineering awards.

features• Transmitter-only,switch-onlyandhybrid

transmitter-switchmodelsoffermaximum

flexibility

• Digitalprocessdisplayprovidesprocess

conditionsataglance

• Programmablesetpointanddeadband

providesthemostversatile,accurateand

repeatablealarmandshutdownswitching

• ConfigurableIAW™self-diagnosticsprovide

pieceofmindthattheinstrumentis

functioningproperlybycommunicatingwith

thecontrolsystemusingadedicateddiscrete

output

• PluggedPortDetectionannunciatesa

cloggedsensorandaclosedbypassvalve

• Max/Minmemory–samplesandstoresthe

highestandlowestextremeprocessvaluesfor

processdiagnosticsandlearning

• Nuisancetripfilteringeliminatesunwanted

nuisancetripsandunnecessaryalarms

• Programmabletripdelay–holdoffthetrip

decisionfortenthsofsecondsuptoseveral

minutes

• Tripcounter–recordstripsforuptotwo

relaysforprocessdiagnosticsandlearning

• 3-yearwarranty

w w w . u e o n l i n e . c o m 3One Series 1X-B-04

POWER

Extremely low power consumption allows the One Series 2-Wire switch-only models (1XSW) to operate with no additional wiring or batteries. Power is obtained from the control system’s discrete input, making it ideal for plant upgrades from mechanical switches, re-using the same wiring and control schemes. The One Series 2-Wire provides a drop-in replacement for mechanical switches and a fast, easy and cost-effective means for plant upgrades.

For direct switching applications, loop-powered hybrid transmitter-switch versions of the One Series can provide 2 independent solid-state relays and handle loads up to 280 volts while providing a field-scalable 4-20 mA analog output – a switch + gauge + transmitter function all-in-one instrument with only one process connection. This reduces installation cost, potential leak paths and maintenance.

PROGRAMMABILITY VIA KEYPAD AND SMART-HART® 7 (included with 1XTX models)

Transmitter-only and hybrid Transmitter-Switch One Series models now feature HART® 7 compatibility. Any function that can be controlled with the keypad can also be controlled with a HART® communicator. This feature makes it unnecessary to remove the enclosure cover to make programming changes or access the MAX/MIN values, especially important in explosive environments. All programming functions can be performed remotely.

The set point and deadband settings allow for 100% adjustability, providing highly repeatable trip and reset points for many different applications. This feature allows the One Series to be used for pump and compressor cycling applications where high cycle rates may shorten the life of mechanical controls. Temperature monitoring models can provide highly repeatable thermostatic control of heaters and chillers. New software features in the One Series allow trip points to be filtered, delayed and counted. Plugged Port Detection can utilize MAX/MIN process extremes data to provide a powerful yet simple tool for detecting clogged impulse lines, rendering these application challenges manageable by the instrument, with no special programming needed at the PLC.

SELF-DIAGNOSTICS

Mechanical switches have no self-diagnostic capabilities – they are blind instruments. All One Series models include UE’s exclusive IAW™ (I Am Working) self-diagnostic system that detects faults before they become process monitoring problems. Detected faults are reported on the digital display while the set point switch will fail safe (change to the tripped state) and the 4-20 mA analog output will go to ≤ 3.6 mA to provide remote fault indication per the NAMUR standard. A separate IAW™ discrete output remains normally closed and will fail-safe-open if a fault is detected or if power is lost. By monitoring this output, the intelligent and configurable IAW™ diagnostics provide immediate remote indication that the One Series remains reliable and available to react to and report process conditions worthy of an alarm and/or shutdown.

4 w w w . u e o n l i n e . c o m One Series 1X-B-04

Foralarmandshutdownmonitoringapplications,thereisnobetterchoicethantheOneSeriesfamilyofhybridtransmitter-switchesfromUnitedElectricControls.Measuringgagepressure,differentialpressureortemperature,theextremelyruggedandreliableOneSeriestakesalloftheguess-workoutofmonitoringprocessvariablestopreventinjury,lossanddowntime.

Withitslargebacklitdigitaldisplay,fullyadjustabledeadbandand100%solid-statedesign,theOneSeriesistheobviouschoice for plant upgrades and new construction projects. A built-in microprocessor includes digital repeatability andintelligentIAW™self-diagnostics,offeringplantoperatorsanextremelyreliableandsmartprocessandcapitalequipmentprotectiondevice.

Proven inuse in literally thousandsofdiverseapplications,UE'sOneSeries isdesigned forharshandhazardous locationprocessmonitoringwith certificates available for intrinsically safe and explosionproof areas including cULus,ATEXandIECExamongothers.SeetheApprovalsandRatingspageforcompleteareaclassificationdetailsandtemperatureratings.

application versatility

Hereareafewapplicationexamples:

• Pumpsandcompressors–start/stop,optimizing,shutdown,staging,fastPDpumpswitching

• Lubricatingoilmonitoring–sealoilpressure,sumptemperature,bearingpressure,predictivemaintenance

• Hydraulicoilpressure–highpressuremonitoring,emergencyshutdown,ramcycling

• Filtermonitoring–automaticbackwash,clogandchangeindication,provingflow

• Plantupgrades–powerandwastewaterplantupgrades,drop-inreplacementformechanicalswitches

SealPressureMonitoringNaturalGasMonitoring

w w w . u e o n l i n e . c o m 5One Series 1X-B-04

Power input/Switch capacity: Model

MaximumPowerRatings/Output

Signal

SetPointSwitchRatings(SPST)

IAW™SwitchRatings(SPST)

Min.LoadRequirement

OffStateLeakage

1XSWLL2-wire7.8–50

[email protected]

7.8–[email protected]@1mA

per°C>25°C

7.8–[email protected]@1mA

per°C>25°C2.7mA 0.8mA

1XSWHL

2-wire70–240VAC&VDC@1

mAdiscreteinputpowered

70–240VAC/[email protected]

7.8–[email protected] 6.0mA 1mA

1XSWHH4-wire70–240VAC

@6mAexternalpowersupply

70–[email protected]–10A

7.8–[email protected] 0.15A 0.1mA

1XTXSW

2-wire20–40VDC@21mA/Looppowered4-20mAanalogoutputwithHART®version7

SW1&SW2:0–280VAC&[email protected]

derate8%per10°C>21°C

0–[email protected]

0mA 0.01mA

1XTX00

2-wire20–40VDC@21mA/Looppowered4-20mAanalogoutputwithHART®version7

N/A N/A N/A N/A

Accuracy: 0.5%offullrangespan,atroomtemperature

Repeatability: 0.1%offullrangespan

Approved ambient operatingtemperaturerange:

Long-term stability: ±0.25%ofrange/yearmaximum

Temperature drift: 0.03%offullscaleper°C(0.12%fortheP10andK10range)

Switch response time: ≤100mSfordetectionoffullstepchangeandchangeofoutputstatewithTripDelayandFilterturnedoff

Analog output response time:

250mSmaximumwithFILTERsettoOFF,pressuremodelsonly

Display response time: 400mS(updated2.5timespersecond)

Filter (transient filtering to prevent nuisance trips):

Programmabletimeconstantsfor0.25*,0.5*,1,and2seconds,defaultOFF

Trip Delay (switch decision delay):

0to999.9secondsin1/10thsecondincrements

*PressureModelsOnly

specifications

Approved Ambient Operating Temperature Range

Model cULus (Division System) cULus & ATEX (zone System)

1XSWLL -40°Fto185°F(-40°CTO85°C) -40°Fto185°F(-40°Cto85°C)

1XSWHL -40˚Fto185˚F(-40˚Cto85˚C) -40˚Fto185˚F(-40˚Cto85˚C)

1XSWHH -40˚Fto158˚F(-40˚Cto70˚C) -40˚Fto158˚F(-40˚Cto70˚C)

1XTXSW -40°Fto185°F(-40°Cto85°C) -40°Fto185°F(-40°Cto85°C)

1XTX00 --40°Fto185°F(-40°Cto85°C) -40°Fto185°F(-40°Cto85°C)

Displayvisibilitytemperaturerange:10°F(-12°C)to158°F(70°C)allmodels

6 w w w . u e o n l i n e . c o m One Series 1X-B-04

Set 4 MA (scale the 4 mA output):

Programmablefrom-3to25%ofthesensor'srange,valuesareintheunitsofmea-sureselectedandarerangedependent

Set 20 MA (scale the 20 mA output):

Programmablefrom50to110%ofthesensor'srange,valuesareintheunitsofmea-sureselectedandarerangedependent

IAW™ (I Am Working) Diagnostics:

Upondetectingafault,thelocaldisplaywillshowafaultcode,thesetpointswitchwillchangetotheas-programmedtrippedstate,thenormally-closedIAW™Outputswitchwillfail-safe-openandtheNAMURNE43standard4-20mAoutputwillindicate≤3.6mA.Seeinstallationmanualforacompletelistingofdetectablefaultsandcodes.

Switch Control modes (N/A for 1XTX00):

mode Set point Switch action iaw™ Output (on fault)

Open risenormally closed, opens at set point on rising media and fault

Opens

Open fallnormally closed, opens at set point on falling media and fault

Opens

close risenormally open, closes at set point on rising media and fault

Opens

close fallnormally open, closes at set point on falling media and fault

Opens

Open Out of window

normally closed, opens above set point high and below set point low and fault, closes below deadband high and above deadband low

Opens

close Out of window

normally open, closes above set point high and below set point low and fault, opens below deadband high and above deadband low

Opens

Analog output (1XTX models only):

4-20mANAMURNE43compliantandHART®version7compatiblecurrentoutput,360ohmsmax.at24VDC,fieldscalable2:1turndown.Faultsareindicatedat≤3.6mA.Seeinstallationmanualfordetails.

Enclosure and cover: Type4X/IP66certifiedepoxy-coatedaluminumalloy360withtemperedglasswindow.SeeDimensionalDrawingsformoredetail.

Conduit: 3/4”NPTfemalealuminumcasting;2openings

Electrical Characteristics: SWITCH STATE

MODEL VOLTAgE OPEN (MAX.) VOLTAgE CLOSED (MAX.)

1XSWLL 7.8 – 50 VDC @ 750 microamps 4.7 VDC @ 0.1 A

1XSWHL 70 – 240 VAC/VDC @ 1 mA 14 VAC/VDC NOMINAL

specifications (continued)

w w w . u e o n l i n e . c o m 7One Series 1X-B-04

IAW™ is a registered trademark of United Electric Controls Co. Specifications subject to change without notice

Display: 4digitx0.5"(12.7mm)backlit*LCDprovidesthefollowinginformation

Processvariable MAX/MINprocessvalues

IAW™(IAmWorking)status Unitsofmeasure

Switchstatus Latchstatus

Setpointvalues Deadbandvalues

Tripcounts Faultcodes

Offsetindication *backliton1XTXmodelsonly

Set point & deadband:

Programmableoverthesensor'sentirerange

Memory: Programminganddataprotectedbynon-volatileFRAM

Effective transmis-sion distance:

2,000feet(610meters)atratedvoltagefor1XSWmodels

Sensors: gage pressure –316Lstainlesssteelwettedparts,weldeddiaphragm,1/2”NPT(female)processconnection,micro-machinedpiezo-resistivestraingagesiliconelement,0.25mlsiliconeoilfill,maximumdiaphragmdisplacement:0.00053inches.

Maximummediatemperature:-40to257°F(-40to125°C)

Vacuum:Allgagepressuresensorswithstanddeepvacuumwithnocalibrationeffects.Forcompoundvacuumranges,seepage8.

differential pressure - 316Lstainlesssteel,weldeddiaphragms,1/4”NPT(male)processconnections,piezo-resistivestraingagesiliconelement,siliconeoilfill.

Maximummediatemperature:-40to257°F(-40to125°C)

temperature – 316stainlesssteel0.25”ODsheathcontaininga100ohm4-wireplatinumRTDelementavailablewithepoxyfill(locallowtemp)orpowderfill(remotehightemp).Mediatemperaturelimits:

-328to1000°F,intermittentto1100°F(-200to538°C,int.to593°C)forTC,THandTTranges

-40to500°F(-40to260°C)forTRandTLranges

EMI/RFI: CompliancetoCEEMCrequirements:EN61000-6-2,EN61000-6-4

Emission: EN61000-6-4ClassA

Immunity: EN61000-4-2ImmunitytoElectrostaticDischargeEN61000-4-3ImmunitytoContinuousRadiatedDisturbancesEN61000-4-4ImmunitytoElectricalFastTransientsEN61000-4-5ImmunitytoSurgesEN61000-4-6ImmunitytoContinuousConductedDisturbancesEN61000-4-11ImmunitytoVoltageDipsandInterruptions

Weight: 4.5-6.0lbs(2.0-2.7kg)dependingonsensor.Add1.9lbs.(0.9kg)foroptionM041

Shock: perMIL-STD-810Gmethod516.6–whendeviceissubjectedto15g(10mSec)and40g(6mSec);3drops/axisEffects:lessthan+/-0.40%ofrange

Vibration: perIEC61298-3(fieldandpipelineapplicationswithhighvibrationlevel,10-1000Hzrange,0.014”displacementpeakamplitude,5gaccelerationamplitude)Effects:lessthan+/-0.40%ofrange

specifications (continued)

8 w w w . u e o n l i n e . c o m One Series 1X-B-04

how to orderBuildapartnumberbyselectingthemodel,sensorandoptionsfromthetablesbelow.

Sensor Pressure Operating Range1 + display resolution4 Maximum Over Range2

Gagepressure,piezo-resistivestraingage,siliconeoilfill,316Lstainlesswettedmaterials,1/2”NPT(female)processconnection,displayedasshown.

P06 -14.7to30psig 831”wc 2068mbar 206.8KPa 2.109kg/cm2 60psig 4137mbar

P08 -14.7to100psig 2770”wc 6,89bar 689KPa 7.03kg/cm2 200psig 13,8bar

P10 0-5.00psig 138.5“wc 344,7mbar 34.47KPa 0.352kg/cm2 10psig 690mbar

P11 0-15.00psig 415.5“wc 1034mbar 103.4KPa 1.055kg/cm2 30psig 2068mbar

P12 0-30.00psig 831“wc 2068mbar 206.8KPa 2.109kg/cm2 60psig 4137mbar

P13 0-50.00psig 1385“wc 3447mbar 344.7KPa 3.516kg/cm2 100psig 6895mbar

P14 0-100.0psig 2770“wc 6,89bar 689KPa 7.03kg/cm2 200psig 13,8bar

P15 0-300.0psig NA 20,68bar 2068KPa 21.09kg/cm2 600psig 41,4bar

P16 0-500.0psig NA 34,47bar 3447KPa 35.16kg/cm2 1000psig 68,9bar

P17 0-1000psig NA 68,9bar 6.89MPa 70.3kg/cm2 2000psig 137,9bar

P18 0-3000psig NA 206,8bar 20.68MPa 210.9kg/cm2 6000psig 413,7bar

P19 0-4500psig NA 310,3bar 31.03MPa 316.4kg/cm2 9000psig 620,5bar

P20 0-6000psig NA 413,7bar 41.37MPa 421.9kg/cm2 12000psig 827,4bar

Example:1XTXSWP15-M041

Model Descriptionzone Division

0 1 2 1 2

1XSWLL(Replaces2W2D,2X2D,2W4D,2X4D)

•2-wire,discreteinputpoweredswitchfor24and48VDClogicsolverinputs

[email protected].

•IAW™healthstatusfail-safe-openswitchratedat7.8-50.0VDC@0.1Awiredseparatelytothelogicsolver

O • • O •

1XSWHL(Replaces2W3Aand2X3A)

•2-wire,discreteinputpoweredswitchfor110and230VAC/VDCand125VDClogicsolverinputs

•Programmablesetpointswitchratedat70-240VAC/[email protected]

•IAW™healthstatusfail-safe-openswitchratedat7.8-50.0VDC@0.1Awiredseparatelytothelogicsolver

• • • •

1XSWHH(Replaces4W3Aand4X3A)

•4-wire,externalpowered70-240VAC•Programmablesetpointratedat70–[email protected]

–10A•IAW™healthstatusfail-safe-openswitchratedat7.8-

[email protected]

• • • •

1XTXSW(Replaces2WLP,2XLP,8W2D,8X2D)

•Loop-powered24VDCHART®enabledsmarttransmitter•Twoprogrammablesetpointfail-safesolidstaterelays

ratedat0-280VAC/[email protected]•IAW™healthstatusfail-safe-openswitchratedat0-

[email protected]

• • • •

1XTX00(TransmitterOnly)

•Loop-powered24VDCHART®enabledsmarttransmitter• • • •

O-asafetybarrierisrequiredforintrinsicallysafeareas,Zone0andDiv.1Exia

w w w . u e o n l i n e . c o m 9One Series 1X-B-04

1-Thepressurerangethatthesensorwillperformwithinspecifiedtolerances.2-Themaximumpressurethatcanbeappliedwithoutaffectingsensorperformance.3-Themaximumpressurethatcanbeappliedtobothportssimultaneouslywithoutaffectingsensorperformance.Pressureonthe“H”sensorportmustbe≥pressure onthe“L”sensorport.4-Thesensorrangetablesaboveprovidethedisplayandsetpointdecimalpointresolutionalongwiththeunitsofmeasureandarespecificforeachrange.IMPORTANT:WhenorderingoptionM201orM202,pleaseobservethedecimalpointresolutionfortherangespecifiedandprovidethesetpointanddeadbandsettingswiththesamenumberofdecimalplacesasfoundinthesetables.

Sensor Pressure Operating Range1 + display resolution4

Differentialpressure,piezo-resistivestraingage,siliconeoilfill,316Lstainlesswettedmaterials,1/4”NPT(male)processconnections,displayedasshown.

K10 0-5.000psid 138.5"wc 344,7mbar 34.47KPa 0.352kg/cm2

K11 0-50.00psid 1385“wc 3447mbar 344.7KPa 3.516kg/cm2

K12 0-100.0psid 2770“wc 6,89bar 689KPa 7.03kg/cm2

K13 0-200.0psid NA 13,79bar 1379KPa 14.10kg/cm2

how to order cont.

Sensor Temperature Range Description (seepage13forsensordrawings)

Temperature–4-wireRTD,100Ωplatinum,DIN0.00385,0.25”ODsensorsheath,316stainlesssteelconstruction

TL1

-40to450°F/-40to232°C(Seepage11fittingoptions)

Local(stem)mountedrigidtoenclosure,4”sheathlength

TL2 Local(stem)mountedrigidtoenclosure,6”sheathlength

TL3 Local(stem)mountedrigidtoenclosure,10”sheathlength

TR1 Remotemounted,2.5”sheath,6’MIfixedextensionlength

TRC Remotemounted,2.5”sheath,1’to60’MIextensionlengthMUSTBESPECIFIED.USEOPTIONW074ONLY.

TH1 -40to1000°F/-40to538°C(Seepage11fittingoptions)

Remotemounted,2.5”sheath,6’MIfixedextensionlength

THC Remotemounted,2.5”sheath,1’to60’MIextensionlengthMUSTBESPECIFIED.USEOPTIONW074ONLY.

TC1* -300to200°F/-184to93°C(Seepage11fittingoptions)

Remotemounted,2.5”sheath,6’MIfixedextensionlength

TCC* Remotemounted,2.5”sheath,1’to60’MIextensionlengthMUSTBESPECIFIED.USEOPTIONW074ONLY.

TTC-40to900°F/-40to482°C

(Example:TTC–NUN6–L10.5)

Local(stem)spring-loadedmount,NUNconnectionlengths:4”–10”in1”increments,variablesheath(L)lengthupto60”,BOTHMUSTBESPECIFIED.Refertodrawingonpage13.Thermowellrequired,seepage11.

Thermowellsandfittingsareshownonpage11.Toordersparesandreplacement temperature sensor assemblies,providethe“TA#:”numberfromtheproductnameplate.Example:TA#:62128723

*Calibration certification is not available on the TC1 and TCC

Sensor Maximum Over Range2 Maximum Working Pressure3

K10 10psid 690mbar 50psig 3447mbar

K11 100psid 6895mbar 500psig 34,47bar

K12 200psid 13,8bar 1500psig 103,4bar

K13 400psid 27,6bar 1500psig 103,4bar

10 w w w . u e o n l i n e . c o m One Series 1X-B-04

OPTION CODES

M041 DualSeal-Providessecondaryprocesssealforallpressuremodels

M201 Factoryprogrammablesetpoint,deadbandandswitchmodeforoneswitch(1XSWModelsOnly)(seeM202for informationrequired)

M202 Factoryprogrammablesetpoint,deadbandandswitchmodefortworelays(Model1XTXSWOnly) (all 6 settings are required when ordering - see example below)

Relay Set Point1 Deadband1 Relay Mode

SW1 040.3 001.5 OPENONFALL

SW2 050.0 005.0 CLOSEONRISE

(For WINDOW modes, all 10 settings are required when ordering - see example below)

Relay Set Point High1

Deadband High1

Set Point Low1 Deadband Low1

Relay Mode

SW1 60.00 12.00 18.50 10.25 OPENWINDOW

SW2 30.50 06.25 09.00 04.75 CLOSEWINDOW

IMPORTANT: When ordering option M201 or M202, please observe the decimal point resolution for the range specified and provide the set point and deadband settings with the same number of decimal places as found in the sensor tables on the previous pages.

M270 Displayunits,degreesCfortemperaturemodels

M275 Displayunits,inchesofwatercolumn

M276 Displayunits,barormbar

M277 Displayunits,kPaorMPa

M278 Displayunits,kg/cm2

M395 FlameproofcomplianceExdperKoreaOccupationalSafetyandHealthAgency(KOSHA)*

M406 ComplianceperRussianEAC*

M444 Papertag

M446 Stainlesssteeltag

M449 Mountingbracketforpipeorwall.Usepartnumber6361-704iforderedseparately.Seepage12foradditional information.

M550 Oxygenservice:CleanedinaccordancewithASTMG93

W073 1/2”NPTmalecompressionfittingforusewithallTLsensors,seepage11foradditionalinformation

W074 1/2”NPTmaleunionconnectorforusewithallTR,THandTCsensors

W081 Thermowelladapter-Adapts3/8"Thermowellto1/4"sensorsheath

W930 1/2”NPTmaletoG1/2maleadapterforusewithgagepressuresensorsP06-P20.Usepartnumber6361-762if orderedseparately.

W932 1/4”NPTfemaletoG1/2maleadapterforusewithdifferentialpressuresensorsK10-K13.Usepartnumber6361- 763iforderedseparately(2required)

6361-752 Replacementcoverassembly1Note: Four digits must be entered for each set point and deadband. Please refer to the display resolution chart on pages 8 & 9 for the correct number of decimal places allowed for the sensor range and units of measure selected.

*Please call for availability

w w w . u e o n l i n e . c o m 11One Series 1X-B-04

temperature sensors and fittings compatibility chartW073 W074 W0801.77"

Ø0.250"

2.285"

Ø0.125"

2.36"

Ø0.188"

Model W073

1/2”NPTcompressionfittingwithferruletofit0.25”sensorsheath

W0741/2”NPTunionconnectiontofit

0.125”sensorextensioncable

1XSW,1XTX TLx TRx,THx,TCx

3/4[19mm]

1[25.4mm]

2 1/2[63.5mm]

1/4[6.4mm]

1/2 NPT

L

P Q

U

Ø.260BORE

Ø1/2[12.7mm]

ThermowellUEPart#

Length(L)Inches

LocalTemperatureSensorsw/0.25”SensorSheath

RemoteTemperatureSensorsw/

0.125”DiameterMICable

P(NPT) Q U TL1(4”) TL2(6”) TL3(10”) TR,TH&TC

1S260L2.5-316 2.5 1/2 5/8 1 W073 W073 W073 W074

1S260L4-316 4 1/2 5/8 2.5 NA W073 W073 W074

1S260L4.5-316 4.5 1/2 5/8 3 NA W073 W073 W074

1S260L5.5-316 5.5 1/2 5/8 4 NA NA W073 W074

1S260L6-316 6 1/2 5/8 4.5 NA NA W073 W074

1S260L6.5-316 6.5 1/2 5/8 5 NA NA W073 W074

1S260L9-316 9 1/2 5/8 7.5 NA NA NA W074

1S260L9.5-316 9.5 1/2 5/8 8 NA NA NA W074

1S260L12-316 12 1/2 5/8 10.5 NA NA NA W074

1S260L15-316 15 1/2 5/8 13.5 NA NA NA W074

1S260L18-316 18 1/2 5/8 16.5 NA NA NA W074

1S260L24-316 24 1/2 5/8 22.5 NA NA NA W074

2S260L2.5-316 2.5 3/4 3/4 1 W073 W073 W073 W074

2S260L4-316 4 3/4 3/4 2.5 NA W073 W073 W074

2S260L6-316 6 3/4 3/4 4.5 NA NA W073 W074

2S260L9-316 9 3/4 3/4 7.5 NA NA NA W074

2S260L12-316 12 3/4 3/4 10.5 NA NA NA W074

2S260L15-316 15 3/4 3/4 13.5 NA NA NA W074

2S260L18-316 18 3/4 3/4 16.5 NA NA NA W074

2S260L24-316 24 3/4 3/4 22.5 NA NA NA W074

Fittings for Thermowells

0.375 REF

0.250REF

2.50REF

SENSORTHERMOWELL ADAPTERThermowell Adapter Option W081

12 w w w . u e o n l i n e . c o m One Series 1X-B-04

dimensional drawings

ENCLOSURE AND SENSOR DETAILS

Shown with Dual Seal option M041 and gage pressure sensor

2" PIPE

B

11/32 WIDE SLOTS (4 PL)

B

BFOR PIPE MOUNTING ORWALL MOUNTING

PIPE MOUNTINGCLAMPS

A

B

ENCLOSURE

C

C

USE

MOUNTINGSCREW(4 PL)

A

(USER SUPPLIED)

Wall or Pipe Mounting BracketOptionM449orpart#6361-704

WARNING:TheOneSeriesunitmustbesecuredtoawallorpipe.Do not use the sensor to support the instrument.ContactUETechnicalSupportat617-923-6977oremailattechsupport@ueonline.com.

[220.98mm]8.7"

[135.62mm]5.3"

1/2NPTPRESSURECONNECTION

1/8NPTBREATHERVENT

[58.42mm]2.3"

138.5mm

5.45”

27.8mm

1.09”

31.8mm1.25”

3/4" NPT (FEMALE)ELECTRICAL CONNECTION(2 PLCS)

72.6mm

2.86” 62mm2.44”

134.6mm

5.30”

5.77”146.5mm

DISPLAY CAN BE ROTATED UP TO 180° BOTH DIRECTIONS

w w w . u e o n l i n e . c o m 13One Series 1X-B-04

temperature SenSOrS

differentiaL preSSure SenSOrS

gage preSSure SenSOrS

1.06[26.9mm]

1/2”-14 NPT (FEMALE)

1/4”-18 NPT (MALE)BOTH ENDS3.0

[76.2mm]

1.06[26.9mm]

dimensional drawings (continued)

4.50[114.3mm]

Ø0.250[6.4mm]

2.50[63.5mm]

L 2.00[50.8mm]

4.50[114.3mm]

Ø0.125[3.2mm]

0.50[12.7mm]

L

0.50[12.7mm]

L NUN 4.50[114.3mm]

0.25[6.35mm]

SPRINGLOAD

TL1-TL3 Sensors

Remote sensors

TTC Sensors

Ø0.250[6.4mm]

Ø0.250[6.4mm] L=60” max., NUN=4” to 10” in 1” increments

14 w w w . u e o n l i n e . c o m One Series 1X-B-04

Approvals & Ratings

Model N. America Europe International Russia Korea

1XSWLL

cULusListedUL:50,50E,913,1203and61010-1.ANSI/ISA12.12.01,ISA12.27.01.CSAC22.2:25,30,157,213,94.01,94.2and61010-1.CSAC22.2/UL:60079,-0,-1,-11,-15,-31.

EN60079-0,EN60079-1,EN60079-11,EN60079-15,EN60079-31

IEC60079-0,IEC60079-1,IEC60079-11,IEC60079-15,IEC60079-31

*Callforavailability *Callforavailability

1XSWLL

CLASSI,DIVISION1GROUPSA,B,C&D;CLASSII,DIVISION1,GROUPSE,F,G;CLASSIII (Note:NogasgroupAwithoptionM041)CLASSI,ZONE1,AExdIIC**T3/T5;ExdIIC**T3/T5;CLASSI,ZONE0,AExiaIICT4;ExiaIICT4;CLASSI,DIVISION2,GROUPSA,B,C&D;CLASSII,DIVISION2,GROUPSE,F,G;CLASSIII(NogasgroupAwithoptionM041) CLASSI,ZONE2,GROUPSAExnAIICT4;ExnAIICT4;-40°C≤Tamb≤85°C(-40°F≤Tamb≤185°F)ENCLOSURETYPE4X,IP66ULFile:E226592

II2GExdbIICT5Gb;II2DExtbIIICT+90°CDb;IP66II1GExiaIICT4Ga;II1DExiaIIICT+135°CDa;-40°C≤Tamb≤85°C(-40°F≤Tamb≤185°F)DEMKO09ATEX0813748X

II3GExnAIICT4Gc;DEMKO15ATEX1483-40°C≤Tamb≤85°C(-40°F≤Tamb≤185°F)

ExdbIIC**T3/T5Gb;ExtbIIICT+90°CDb;IP66ExiaIICT4Ga;ExtbIIICT+135°CDa;IECExUL08.0017X-40°C≤Tamb≤85°C(-40°F≤Tamb≤185°F)

*Callforavailability *Callforavailability

Model N. America Europe International Russia Korea

1XTXSW,1XTX00,1XSWHL,1XSWHH

cULusListedUL:50,50E,913,1203and61010-1.ANSI/ISA12.12.01,ISA12.27.01.CSAC22.2:25,30,213,94.01,94.2and61010-1.CSAC22.2/UL:60079,-0,-1,-15,-31.

EN60079-0,EN60079-1,EN60079-15,EN60079-31

IEC60079-0,IEC60079-1,IEC60079-15,IEC60079-31

*Callforavailability *Callforavailability

1XTXSW,1XTX00,1XSWHL,1XSWHH

CLASSI,DIVISION1,GROUPSA,B,C&D;CLASSII,DIVISION1,GROUPSE,F,G;CLASSIII (Note:NogasgroupAwithoptionM041)CLASSI,ZONE1,AExdIIC**T3/T5;ExdIIC**T3/T5;CLASSI,DIVISION2,GROUPSA,B,C&D;CLASSII,DIVISION2,GROUPSE,F,G;CLASSIII(NogasgroupAwithoptionM041) CLASSI,ZONE2,GROUPSAExnAIICT4;ExnAIICT4;-40°C≤Tamb≤85°C(-40°F≤Tamb≤185°F)ENCLOSURETYPE4X,IP66ULFile:E226592

II2GExdbIIC**T3/T5Gb;II2DExtbIIICT+90°CDb;IP66-40°C≤Tamb≤85°C(-40°F≤Tamb≤185°F)DEMKO09ATEX0813748X

II3GExnAIICT4Gc;DEMKO15ATEX1483-40°C≤Tamb≤85°C(-40°F≤Tamb≤185°F)

ExdbIIC**T3/T5Gb;ExtbIIICT+135°CDb;IECExUL08.0017X-40°C≤Tamb≤85°C(-40°F≤Tamb≤185°F)

*Callforavailability *Callforavailability

**T3forpressuresensorrangesP06,P08,andP10-P16only.T5forallothermodels.Specificationssubjecttochangewithoutnotice.

w w w . u e o n l i n e . c o m 15One Series 1X-B-04

additional products from ue

12 Series –Electro-MechanicalPressureandTemperatureSwitch

• Compact,cylindrical316stainlesssteeldesign• Hermeticallysealedmicro-switch• ExplosionProof;Div.1,Zone1certifiedforhazardouslocations• Snap-actingbellevillespringmechanismformaximumvibrationresistanceandsetpointstability

• Pressureranges1to12,500psi;DPworkingpressureranges0to1200psi;Temperatureranges-130°to650°F

• DualsealcompliancetoANSI/ISA12.27.01

120 Series –Electro-MechanicalPressureandTemperatureSwitch

• Explosion-prooflineofpressure,differentialpressure,andtemperaturemodelswithwideselectionofranges,sensorsandpressureconnections

• Div.1,Zone1certifiedforhazardouslocations• Singleordualswitchoutputs• Weldedstainlesssteeldiaphragmpressuresensor• Internalorexternalsetpointadjustment

TX200 Series HART® & ASIC Pressure Transmitter

• SmartTX200HoffersHART7communciationand4-20mAoutput• TX200H10:1rangeturndownhelpsreduceinventory• ASICbasedTX200offers4-20mAoutputor1-5VDCor0-10VDCoutput• Rugged316stainlesssteelconstruction,weldedandhermeticallysealed• Div.1,Zone1certifiedforhazardouslocations• Widevarietyofprocessconnectionsavailableforpressurerangesfrom0to15psi

upto0to25,000psi

Temperature Sensors

RuggedRTDsandthermocouplesforprocessandenergyapplications,availablewithNema4Xandexplosion-proofheadstomatchheat-trace,turbine,combustion,andstack-emissionapplications

• ImproveAvailabilitywithreducednuisancetrips

• ImproveUptimewithsafetydiagnostics

• ImproveSafetywithSROtoensuresafetyfunction

• LowerInventory-atransmitter,switchandgaugeinone

• SimplifyComplexSafetySystemswithSFF=98.8%

• ReduceMigrationCostswithbackwardandforwardcompatibility

One Series Safety Transmitter -PressureandTemperatureTransmitter-Switch

DUAL SEALCERTIFIED

DUAL SEALCERTIFIED

180DexterAvenue,P.O.Box9143Watertown,MA02471-9143USATelephone:617926-1000Fax:617926-2568www.ueonline.com

U N I T E D E L E C T R I C C O N T R O L S

CP05125000

RECOMMENDED PRACTICES AND WARNINGS UnitedElectricControlsCompany recommendscareful considerationof the following factors when specifying and installing UE pressureand temperature units. Before installing a unit, the Installationand Maintenance instructions provided with unit must be read andunderstood.

• Toavoiddamagingunit,proofpressureandmaximumtemperaturelimits stated in literature and on nameplates must never beexceeded,evenbysurgesinthesystem.Operationoftheunituptomaximumpressureortemperatureisacceptableonalimitedbasis(e.g.,start-up,testing)butcontinuousoperationmustberestrictedtothedesignatedadjustablerange.Excessivecyclingatmaximumpressureortemperaturelimitscouldreducesensorlife.

• A back-up unit is necessary for applications where damage toa primary unit could endanger life, limbor property. A high orlowlimitswitchisnecessaryforapplicationswhereadangerousrunawayconditioncouldresult.

• The adjustable range must be selected so that incorrect,inadvertentormalicioussettingatanyrangepointcannotresultinanunsafesystemcondition.

• Install unit where shock, vibration and ambient temperaturefluctuations will not damage unit or affect operation. Whenapplicable, orient unit so that moisture does not enter theenclosure via the electrical connection. When appropriate, thisentrypointshouldbesealedtopreventmoistureentry.

• Unitmustnotbealteredormodifiedaftershipment.ConsultUEifmodificationisnecessary.

• Monitoroperationtoobservewarningsignsofpossibledamageto unit, such as drift in set point or faulty display. Check unitimmediately.

• Preventative maintenance and periodic testing is necessary forcritical applications where damage could endanger property orpersonnel.

• Electricalratingsstatedinliteratureandonnameplatemustnotbeexceeded.Overloadonaswitchcancausedamage,evenonthefirstcycle.Wireunitaccordingtolocalandnationalelectricalcodes,usingwiresizerecommendedininstallationsheet.

• Donotmountunitinambienttemp.exceedingpublishedlimits.

LIMITED WARRANTYSeller warrants that the product hereby purchased is, upon delivery,free from defects in material and workmanship and that any suchproduct which is found to be defective in such workmanship ormaterial will be repaired or replaced by Seller (Ex-works, Factory,Watertown, Massachusetts. INCOTERMS); provided, however, that thiswarranty applies only to equipment found to be so defective withina period of 36 months from the date of manufacture by the Seller.Seller shall not be obligated under this warranty for alleged defectswhich examination discloses are due to tampering, misuse, neglect,improper storage, and in any case where products are disassembledbyanyoneother thanauthorizedSeller’s representatives.EXCEPTFORTHE LIMITED WARRANTY OF REPAIR AND REPLACEMENT STATEDABOVE, SELLER DISCLAIMS ALL WARRANTIES WHATSOEVER WITHRESPECT TO THE PRODUCT, INCLUDING ALL IMPLIED WARRANTIESOFMERCHANTABILITYORFITNESSFORANYPARTICULARPURPOSE.

LIMITATION OF SELLER’S LIAbILITYSELLER’SLIABILITYTOBUYERFORANYLOSSORCLAIM,INCLUDINGLIABILITY INCURRED IN CONNECTION WITH (I) BREACH OF ANYWARRANTYWHATSOEVER,EXPRESSEDORIMPLIED,(II)ABREACHOFCONTRACT,(III)ANEGLIGENTACTORACTS(ORNEGLIGENTFAILURETOACT)COMMITTEDBYSELLER,OR(IV)ANACTFORWHICHSTRICTLIABILITYWILLBEINPUTTEDTOSELLER,ISLIMITEDTOTHE“LIMITEDWARRANTY”OFREPAIRAND/ORREPLACEMENTASSOSTATEDINOURWARRANTYOFPRODUCT.INNOEVENTSHALLTHESELLERBELIABLEFORANYSPECIAL,INDIRECT,CONSEQUENTIALOROTHERDAMAGESOF A LIKE GENERAL NATURE, INCLUDING, WITHOUT LIMITATION,LOSSOFPROFITSORPRODUCTION,ORLOSSOREXPENSESOFANYNATUREINCURREDBYTHEBUYERORANYTHIRDPARTY.

UE specifications subject to change without notice.

Besuretovisitwww.ueonline.comforthelatestinformationregardingtheOne Series.16

FORALISTOFOURINTERNATIONALANDDOMESTICREGIONALSALESOFFICESPLEASEVISITOUR

WEBPAGEWWW.UEONLINE.COM