On-Site Septic & Water TanksIts low-profile design is ideal where bedrock, or other factors which...

13
On-Site Septic & Water Tanks Phone: 402-467-5221 • Fax: 402-465-1220 • [email protected] Corporate Offices: P.O. Box 4583 • Lincoln, Nebraska • 68504 Other Manufacturing Facilities: Lincoln, Nebraska • Philippi, West Virginia • Chowchilla, California • Marked Tree, Arkansas www.snydernet.com Snyder’s Rain Captor Catalog provides a complete listing of all Sny- der’s Residential and Commercial Rainwater Collection Systems.

Transcript of On-Site Septic & Water TanksIts low-profile design is ideal where bedrock, or other factors which...

Page 1: On-Site Septic & Water TanksIts low-profile design is ideal where bedrock, or other factors which restrict hole depth, limit the ability or accessibility to install any other septic

On-Site Septic & Water Tanks

Phone: 402-467-5221 • Fax: 402-465-1220 • [email protected] Corporate Offices: P.O. Box 4583 • Lincoln, Nebraska • 68504

Other Manufacturing Facilities: Lincoln, Nebraska • Philippi, West Virginia • Chowchilla, California • Marked Tree, Arkansas

www.snydernet.com

Snyder’s Rain Captor Catalog provides a complete listing of all Sny-der’s Residential and Commercial Rainwater Collection Systems.

Page 2: On-Site Septic & Water TanksIts low-profile design is ideal where bedrock, or other factors which restrict hole depth, limit the ability or accessibility to install any other septic

KEY FOR TANK AVAILABILITY: A = All locations • C = Chowchilla, CA • L = Lincoln, NE • M = Marked Tree, AR • P = Philippi, WV KEY FOR TANK AVAILABILITY: A = All locations • C = Chowchilla, CA • L = Lincoln, NE • M = Marked Tree, AR • P = Philippi, WV

Dominator was designed utilizing state-of-the-art FEA techniques and then field tested to provide a tank with extraordinary structural integrity. Because of this, the tank line is ideal for a variety of uses and uses in a variety of extreme site conditions. Its low-profile design is ideal where bedrock, or other factors which restrict hole depth, limit the ability or accessibility to install any other septic tank. In challenging conditions, this is the tank to choose. Refer to “Site Selection” document on www.snydernet.com.

Dominator SEPTIC TANKS

Angled Bottom to help direct water away from tank

Double walled lid w/kiss-off. 20” Man hole access.

Stabilization Lug

2

Single Compartment - Unplumbed version - tank has no holes drilled and is shipped with 2 gaskets and 1 invert pipe.

Simplex No. Part No. Gallon Capacity Tank F.O.B. Length Width HeightNo. of

ManholesST31DU 1001210W95308 750 Low Profile Dominator A 96” 60” 51” 2 - 20”ST51DU 1001010W95308 1000 Low Profile Dominator A 126” 60” 51” 2 - 20”ST61DU 1001411W95308 1250 Low Profile Dominator A 161” 60” 51” 2 - 20”ST71DU 1001511W95306 1500 Low Profile Dominator A 191” 60” 51” 2 - 20”

Single Compartment - pre-plumbed version - tank has inlet and outlet tee assemblies installed i nto the tank.

Simplex No. Part No. Gallon Capacity Tank F.O.B. Length Width HeightNo. of

ManholesST31DP 1001210W95313 750 Low Profile Dominator A 96” 60” 51” 2 - 20”ST51DP 1001010W95315 1000 Low Profile Dominator A 126” 60” 51” 2 - 20”ST61DP 1001411W95305 1250 Low Profile Dominator A 161” 60” 51” 2 - 20”ST71DP 1001511W95304 1500 Low Profile Dominator A 191” 60” 51” 2 - 20”

• Maximum burial depth of 36”.• No water required for backfill.• Tanks are designed for buried applications only in non-traffic installations.• Maximum temperature of influent is 100 degrees F.• IAPMO & CSA versions available.

Page 3: On-Site Septic & Water TanksIts low-profile design is ideal where bedrock, or other factors which restrict hole depth, limit the ability or accessibility to install any other septic

KEY FOR TANK AVAILABILITY: A = All locations • C = Chowchilla, CA • L = Lincoln, NE • M = Marked Tree, AR • P = Philippi, WV

Dominator SEPTIC TANKS

51” overall tank height allows shallower burial.

3

Double Compartment - tank has no holes drilled and is shipped with 2 gaskets and 1 invert pipe.Simplex No. Part No. Gallon Capacity Tank F.O.B. Length Width Height No. of Manholes

ST32DU 1001210W95306 750 Low Profile Dominator (2/3-1/3) A 96” 60” 51” 2 - 20”ST52DU 1001010W95306 1000 Low Profile Dominator (2/3-

1/3) A 126” 60” 51” 2 - 20”

ST62DU 1001411W95306 1250 Low Profile Dominator (2/3-1/3)

A 161” 60” 51” 2 - 20”

ST72DU 1001511W95307 1500 Low Profile Dominator (2/3-1/3)

A 191” 60” 51” 2 - 20”

Double Compartment - tank has inlet and outlet tee assemblies installed into the tank.Simplex No. Part No. Gallon Capacity Tank F.O.B. Length Width Height No. of Manholes

ST32DP 1001210W95312 750 Low Profile Dominator (2/3-1/3) A 96” 60” 51” 2 - 20”ST52DP 1001010W95314 1000 Low Profile Dominator (2/3-

1/3) A 126” 60” 51” 2 - 20”

ST62DP 1001411W95304 1250 Low Profile Dominator (2/3-1/3)

A 161” 60” 51” 2 - 20”

ST72DP 1001511W95303 1500 Low Profile Dominator (2/3-1/3)

A 191” 60” 51” 2 - 20”

Isolated man hole with double walled lid w/kiss-off resists

defomation.

Top male ribs provide added strength against top loading.

Radial reinforcement bands and tie tubes provide superior radial strength.

Page 4: On-Site Septic & Water TanksIts low-profile design is ideal where bedrock, or other factors which restrict hole depth, limit the ability or accessibility to install any other septic

KEY FOR TANK AVAILABILITY: A = All locations • C = Chowchilla, CA • L = Lincoln, NE • M = Marked Tree, AR • P = Philippi, WV KEY FOR TANK AVAILABILITY: A = All locations • C = Chowchilla, CA • L = Lincoln, NE • M = Marked Tree, AR • P = Philippi, WV

NuConSept RIBBED SEPTIC TANKS

Simplex # Part No. Gallon Capacity Pre-Plumbed Tank F.O.B. Length Width Height No. of Manholes

SMALL SEPTIC TANKSST21L 1000900W95301 500 Low Profile Yes A 88” 48” 42” 1 - 20”

ST21LU 1000900W95303 500 Low Profile ,Unplumbed No A 88” 48” 42” 1 - 20”ST11S 5260000W95302 300 Sphere Yes A 48.5” 48.5” 53” 1 - 20”ST21S 5170000W94203 500 Sphere Yes A 60” 60” 63” 1 - 20”

NuConSept Ribbed Septic Tanks - SINGLE COMPARTMENTSimplex # Part No. Gallon Capacity Pre-Plumbed Tank F.O.B. Length Width Height No. of ManholesST51RU 5060000W95301 1050 No A 100” 64” 62” 2 - 20”ST51R 5060000W95307 1050 Yes A 100” 64” 62” 2 - 20”

ST61RU 5080000W95301 1250 No A 119” 64” 62” 2 - 20”ST61R 5080000W95307 1250 Yes A 119” 64” 62” 2 - 20”

ST71RU 5120000W95301 1500 No A 140” 64” 62” 2 - 20”ST71R 5120000W95307 1500 Yes A 140” 64” 62” 2 - 20”

NuConSept Septic Tanks - DOUBLE COMPARTMENTST52RU 5060000W95303 1050 (2/3 - 1/3) No A 100” 64” 62” 2 - 20”ST52R 5060000W95302 1050 (2/3 - 1/3) Yes A 100” 64” 62” 2 - 20”

ST62RU 5080000W95303 1250 (2/3 - 1/3) No A 119” 64” 62” 2 - 20”ST62R 5080000W95302 1250 (2/3 - 1/3) Yes A 119” 64” 62” 2 - 20”

ST72RU 5120000W95303 1500 (2/3 - 1/3) No A 140” 64” 62” 2 - 20”ST72R 5120000W95302 1500 (2/3 - 1/3) Yes A 140” 64” 62” 2 =- 20”

These tanks are designed for below-ground use only. We have a more economical line of above ground tanks available for above ground use (see pages 7, 8 and 9). With the exception of the spherical septic tanks, the tanks presented on this page are not to be used as pump tanks or holding tanks. (If the need exists for tanks larger than 500 gallons to be used as pump or holding tanks, see Dominator on page 3). State and/or county health codes regulate the use of our septic tanks. Please contact your local health department for specific codes in your area.

4

• Sturdy Ribbed design.• Maximum burial depth is 24”.• With the exception of the 300 and 500 sphere tanks, tanks on this page are NOT to be used as holding tanks or pumps tanks.• Tanks are designed for buried applications only in non-traffic installations.

• Maximum temperature of influent is 100 degrees F.• Pre-plumbed septic tanks are provided with gasketed inlet tee and gasketed outlet tee already installed into the tank. • Unplumbed septic tanks are provided with no holes cut in the tank and two gaskets. • Tanks sold in the states of Indiana and West Virginia are pre-drilled. • IAPMO & CSA versions available.

Page 5: On-Site Septic & Water TanksIts low-profile design is ideal where bedrock, or other factors which restrict hole depth, limit the ability or accessibility to install any other septic

KEY FOR TANK AVAILABILITY: A = All locations • C = Chowchilla, CA • L = Lincoln, NE • M = Marked Tree, AR • P = Philippi, WV

Part No. Description34701546 NuConSept Ribbed Tank Tee Assembly (no

gasket)34200852 Dominator Low Profile Tee34701330 2” Invert Pipe34701197 Tamper resistant bolt kit (4 bolst; one driver bit)33100217 4” Septic Gasket34701333 Cistern U-Vent assembly34300028 6” Riser (6”H x 20”D)34300029 12” Riser (12” H x 20” D)34300030 18” Riser (12” H x 20” D)34300018 Septic/cistern lid34700605 Septic/cistern lid with 4” inspection port34700606 Septic/cistern lid with 6” inspection port5220000W94201 Septic/cistern lid with 12” riser x 30” height

Risers

FITTINGS AND ACCESSORIES Septic & Cistern

5

FITTINGS AND ACCESSORIES

Simplex # Part No. Gallon Capacity Tank F.O.B. Length Width Height No. of ManholesPT1S 5260000W95301 300 Gal. Sphere A 48.5” 48.5” 49.5” 1 - 20”PT2S 5170000W94201 500 Gal. Sphere A 60” 60” 63” 1 - 20”PT5D 1001001W95308 1000 Gal. Dominator L,M,P 126” 60” 51” 2 - 20”

PT5NC 1001001W95311 1000 N.Carolina Dominator L,M,P 126” 60” 51” 2 - 20” & 1 - 24”PT6D 1001411W95308 1250 Gal. Dominator L,M,P 161” 60” 51” 2 - 20”

PT6NC 1001411W95307 1250 N. Carolina Dominator L,M,P 161” 60” 51” 2 - 20” & 1 - 24”PT7D 1001511W95306 1500 Gal. Dominator L,M,P 191” 60” 51” 2 - 20”

PT7DNC 1001511W95307 1500 N. Carolina Dominator L,M,P 191” 60” 51” 2 - 20” & 1 - 24”

300 & 500 Gallon

PUMP TANKS• Pump tanks are furnished with manhole covers only. • Only inlet is cut for tee.

Page 6: On-Site Septic & Water TanksIts low-profile design is ideal where bedrock, or other factors which restrict hole depth, limit the ability or accessibility to install any other septic

KEY FOR TANK AVAILABILITY: A = All locations • C = Chowchilla, CA • L = Lincoln, NE • M = Marked Tree, AR • P = Philippi, WV KEY FOR TANK AVAILABILITY: A = All locations • C = Chowchilla, CA • L = Lincoln, NE • M = Marked Tree, AR • P = Philippi, WV

6

Underground WATER CISTERNS

•Ideal for underground storage of potable • Thicker-wall version of septic tank design. water, fire protection water, gray water or rainwater. • Multiple fitting locations. • Same watertight features as septic tanks. • Tanks may be easily plumbed together in • Manufactured from high-density linear series to increase total underground polyethylene (HDLPE)-complies with FDA storage capacity. Reg. 21 CFR 177.1520 {C3.1} and NSF.

Cistern Specifications - Below GroundSimplex # Part. No. Gallon Capacity Tank F.O.B. Length Width Height No. of Manholes

C1S 5260000W97401 325 Sphere A 48.5” 48.5” 53” 1 - 20”C2S 5170000W97401 525 Sphere A 60” 60” 63” 1 - 20”C5R 5060000W97401 1200 Ribbed C,M,P 100” 64” 62” 2 - 20”C7R 5120000W97401 1700 Ribbed C,M,P 140” 64” 62” 2 - 20”

Cisterns are furnished with manhole cover(s) only.

UNDERGROUND CISTERN TANKS

Low Profile C2L 1000900W97401 575 Low Profile A 88” 48” 42” 1 - 20”C5D 1001010W97401 1200 Dominator A 126” 60” 51” 2 - 20”C7D 1001511W97401 1700 Dominator A 191” 60” 51” 2 - 20”

• Cisterns are furnished with manhole covers only.• Cisterns should be vented per the installation instructions.

Underground water storage capacity is sometimes desirable in applications where seasonal freezing occurs or where aesthetics will not allow the use of an above-ground water tank.

Page 7: On-Site Septic & Water TanksIts low-profile design is ideal where bedrock, or other factors which restrict hole depth, limit the ability or accessibility to install any other septic

KEY FOR TANK AVAILABILITY: A = All locations • C = Chowchilla, CA • L = Lincoln, NE • M = Marked Tree, AR • P = Philippi, WV

Septic Tanks Do’s and Don’ts

•Ideal for underground storage of potable • Thicker-wall version of septic tank design. water, fire protection water, gray water or rainwater. • Multiple fitting locations. • Same watertight features as septic tanks. • Tanks may be easily plumbed together in • Manufactured from high-density linear series to increase total underground polyethylene (HDLPE)-complies with FDA storage capacity. Reg. 21 CFR 177.1520 {C3.1} and NSF.

DO: • read and follow all portions of the SII installation instructions for your tank and the Site Selection/Preparation document available

at HYPERLINK “http://www.snydernet.com” www.snydernet.com.• call 402-467-5221 if you any questions about the tanks, installation instructions, or the Site Selection/Preparation document• use the tanks for underground and septic applications only.• ensure the installer complies with all state, county, and local codes and regulations regarding the tanks and installation.• document the tank serial number (10 digit number located under the inlet) and model number for all warranty inquiries.• use either lifting eyes or corner lifting lugs when handling the tanks.• exercise caution and safe practices in handling and installing the tank.• exercise caution with any object which may damage or puncture tanks including forklifts and excavating equipment. • locate the septic tank in an area that not be subjected to excessive pressures from elevated ground water during rain events.• call 402-467-5221 if saturated soil or seasonable water tables are indicated for special instructions.• install the tank parallel to any slope as discussed in the Site Selection/Preparation document.• locate the tank in an area where it will not experience vehicular traffic.• ensure the tank is level and bedded in 50/50 mixture of sand and gravel per SII installation instructions.• ensure the connections between tanks, risers, and lids are water tight and installed per SII installation instructions.• ensure the connections in and out tank are water tight—inlet and outlet connections must be made via watertight connection.• maintain the max & min burial depths—36” max: Dominator and Sphere tanks—24” max: Ribbed tanks—9” min: all tanks.• ensure all backfill material is free of all debris including wood, concrete, rocks/boulders, masonry debris, etc.• ensure all backfill material is free of clay and will not create voids greater than ¼”. Note: for NuConSept ribbed tanks only -

backfill must be 50% sand/gravel mixture. Use 3/8” to 1/2” pea or river gravel.• backfill around the tank evenly and uniformly in lightly compacted 12” layers. • ensure proper venting is maintained to the house vent for each septic and/or pump tank.• ensure all “pre-cover” inspections, if necessary, are completed prior to completing the backfilling to finish grade.• mound the excavation a min. of 5” above finish grade to allow for drainage away from the tank per SII installation instructions.• ensure all water runoff from sloping terrain, adjacent structures, paved surfaces, etc. is diverted away form the tank installation.• note the location of the inlet and outlet manholes for inspection and maintenance purposes.• inspect your system (every 2-3 years) and pump your tank as necessary (generally every 3 to 5 years).

DON’T:• use septic/pump tanks for any other application other than it intended use—cisterns are available for underground water

applications and above ground tanks for above ground applications.• use the tank as a grease trap or subject the tank to water temperature higher than 1000 F.• subject the tanks to drops from higher than 48”.• subject the tanks to impact in cold weather.• locate tanks at the bottom of sloping terrain unless adequate measures are taken to prevent water runoff from infiltrating the tank

excavation.• locate tanks at the lowest point of the grade—in this situation mounding alone may not provide enough drainage away from the

tank excavation.• locate a septic or pump tank beneath driveways or in the pathway of heavy or vehicular traffic areas.• over-excavate or “belly-out” the excavation.• install the tanks with backfill containing clay, wood, concrete, rock/boulders, masonry debris, etc.• leave a tank excavation open without adequately protecting the tank excavation from rain water infiltration.• backfill only to the finish grade level—eventually the settled ground will cause rainwater to pool. • allow water runoff to be directed towards or near any part of the septic system.• allow vehicular traffic over the location of the septic system.• plant trees, shrubs or a garden near the septic system—roots may clog or damage the system.• enter your tank—septic gases can deplete the amount of oxygen, which can lead to affixation.

IMPORTANT: Before installing Snyder Septic Tanks, you must read Snyder Site Selection/Preparation document and follow the guidelines provided; and, Installation Procedures provided for each type of tank. Failure to follow these instructions, WILL VOID YOUR WARRANTY. Both documents can be found on the Snyder web site: www.snydernet.com.

7

Page 8: On-Site Septic & Water TanksIts low-profile design is ideal where bedrock, or other factors which restrict hole depth, limit the ability or accessibility to install any other septic

KEY FOR TANK AVAILABILITY: A = All locations • C = Chowchilla, CA • L = Lincoln, NE • M = Marked Tree, AR • P = Philippi, WV KEY FOR TANK AVAILABILITY: A = All locations • C = Chowchilla, CA • L = Lincoln, NE • M = Marked Tree, AR • P = Philippi, WV

ABOVE GROUND WATER STORAGE TANKS

• All materials are UV stabilized for long-term outdoor service. • Gallon indicators molded in most tanks. • Manufactured from FDA-approved resin for potable water. • Weatherproof threaded lids with built-in anti-surge vents. • Bolt-on fittings with stainless steel bolts. • Molded-in tie down slots and lifting lugs.

Simplex No. Part No. Gallon Capacity Tank F.O.B. Diameter Height Fill Opening DrainWV3 1550000W94301 65 Vertical L 23” 47.75” 6” 3/4”WV6 1012700W94301 100 Vertical P 30” 41” 18” 2” B.O.WV5 1540200W94301 120 Vertical C 32” 38” 10” 1 1/2”WV7 1012800W94301 150 Vertical P 30” 58 1/2” 188” 2” B.O.

WV7R 1008400W94301 175 Vertical L,M 29” 66” 18” 2” B.O.WV8 1012900W94301 210 Vertical P 38” 54 1/2” 18” 1 1/2”WV9 101300W94301 290 Vertical P 36” 72” 18” 2” B.O.

WV10 154300W94302 200 Vertical C 36” 59” 10” 1 1/2”WV21 1630000W94301 300 Vertical M 35” 78” 18” 2” B.O.WV22 1630100W94301 300 Vertical C 36” 82” 10” 1 1/2”

WV24R 1008200W94301 330 Vertical C 47” 49 1/2” 18” 2” B.O.WV30 1800000W94301 550 Narrow Vert. L 48” 74” 18” 2” B.O.

WV30P 1800000W94301 550 Narrow Vert. P 48” 74” 18” 2” B.O.WV31R 109600W94301 500 Narrow Vert. C 47” 77” 18” 2” B.O.WV30R 1011700W943-- 500 Narrow Vert M 47” 77” 18” 2” B.O.WV31 1800300W94301 525 Narrow Vert. C 48” 76” 18” 2” B.O.WV33 1820000W94301 550 Vertical L,C 64” 46” 18” 2” B.O.WV32 8060000W94301 550 Vertical M,P 64” 46” 18” 2” B.O.WV40 1830000W94302 1100 Narrow Vert. L,P 64” 87” 18” 2” B.O.

WV41R 108600W943-- 1000 Narrow Vert. C 72” 65” 18” 2” B.O.WV40R 1013300W94302 1025 Narrow Vert. M 60” 95 1/2” 18” 2” B.O.WV42 1710200W94302 1100 Vertical C,L,P 86” 53” 10” 2” B.O.WV43 8120000W94302 1100 Vertical M 86” 55” 18” 2” B.O.WV45 1770300W94302 1500 Vertical C,L,P 86” 70” 10” 2” B.O.WV47 8120100W94301 1500 Vertical M 86” 70” 18” 2” B.O.WV50 5050000W94302 2000 Vertical L,P 90” 88” 18” 2” B.O.WV51 8130000W94301 2000 Vertical M 90” 88” 18” 2” B.O.WV52 5050100W94302 2000 Vertical C 96” 84” 18” 2” B.O.WV60 5090000W94301 2500 Vertical L,P 90” 106” 18” 2” B.O.WV61 8140000W94302 2500 Vertical M 90” 106” 18” 2” B.O.

WV61R 1012300W943-- 2500 Vertical M 102” 85 1/2” 18” 2” B.O.WV62 5090200W94301 2600 Vertical C 96” 89” 18” 2” B.O.WV70 5130000W94302 3000 Vertical L,P 90” 125” 18” 2” B.O.WV71 8160000W94301 3000 Vertical M 90” 125” 18” 2” B.O.WV72 5130200W94301 3000 Vertical C 96” 109” 18” 2” B.O.WV80 7420000W94301 4700 Vertical L 102” 142.5” 18” 2” B.O.WV81 8210000W94301 5000 Vertical M 102” 153” 18” 2” B.O.WV82 1002000W94302 5000 Vertical P 102” 155” 18” 2” B.O.WV83 7420100W94302 5000 Vertical C 102” 157” 24” 2” B.O.WV90 7430000W94302 6000 Vertical L,P,C 102” 188” 18” 2” B.O.WV91 8220000W94301 6250 Vertical M 120” 140” 18” 2” B.O.

WV100 5330200W94301 10,000 Vertical C 144” 161” 18” 3” B.O.WV101 5330000W94301 10,500 Vertical L,P 142” 169 3/4” 18” 3” B.O.

8

Snyder provides a wide range of above-ground storage tanks for indoor or outdoor use where wells do not meet the consumption needs of the users. In addition, Snyder has a variety of horizontal tanks, utility (pickup truck) tanks, and PCO tanks that are ideal for hauling water. All Snyder water tanks are manufactured from FDA ap-proved resins and manufac-tured in NSF-certified facilities. Optional fittings are available as listed on page 10.

Page 9: On-Site Septic & Water TanksIts low-profile design is ideal where bedrock, or other factors which restrict hole depth, limit the ability or accessibility to install any other septic

KEY FOR TANK AVAILABILITY: A = All locations • C = Chowchilla, CA • L = Lincoln, NE • M = Marked Tree, AR • P = Philippi, WV

ABOVE GROUND WATER STORAGE

Simplex No. Part No. Gallon Capacity Tank F.O.B. Diameter/Width Height Length Fill DrainWH1 1080000W94301 30 Horizontal Leg A 23” 26” 19” 6” -WH2 1060000W94301 60 Horizontal Leg A 23” 26” 38.5” 6” 3/4”

Above requires a minimum of one - P/N 33900093 - 30/60 Band (2 bands are optional). Each pair of bands requires a P/N 34700014 j-bolt package (4 j-bolts)

WH3** 1120000W94301 125 Horizontal Leg L,P,C 30” 34.5” 49.5” 10” 1 1/4” Above requires a minimum of one - P/N 33900094 - 125 Band (2 are optional). Each pair of bands requires P/N 34700014, j-bolt package (4 j-bolts)

WH4** 1280000W94301 230 Horizontal Leg L,P,C 38” 42.5” 51.5” 10” 1 1/4”WH5 1320000W94302 300 Horizontal Leg L,M,P 38” 42.5” 72” 10” 1 1/4”WH6 1320100W94302 300 Horizontal Leg C 38” 42.5” 67” 10” 1 1/4”

Above requires a minimum off one - P/N 33900095 - 230/300 Band (2 are optional). Each pair of bands requires P/N 34700014, j-bolt package (4 j-bolts).WH7 1400100W95001 500 Horizontal Leg C 49” 55” 72” 18” 2”WH8 1400000W95001 525 Horizontal Leg L,M,P 48” 52.5” 75” 10” 2”

Above requires a minimum of one - P/N 33900096 - 500/525 Band (2 are optional). Each pair of bands requires P/N 34700014, j-bolt package (4 j-bolts).

WH10 7500000W94301 3000 Horizontal Leg C,M,L 92” 76” 142” 18” 3” 459020**Hoop Assembly Required. Assembly includes 4 hoops and required j-bolts **WH3 & WH4 are also offered out of Marked Tree plant, dimensions are different - contact Customer Service or visit www.snydernet.com.

Simplex No. Part No. Gallon Capacity Tank F.O.B. Diameter/Width Height Fill DrainWU1/WU1C 1600000W94302 150/210 Utility P/C 54”/60” 22”/29” 10” 2”WU2/WU2C 1620000W94302 300/325 Utility P/C 65”/62” 29”/33” 10” 2”WU3/WU3C 1650000W94302 465/425 Utility P/C 65”/65” 45”/35” 10” 2”

Utility Tanks (Tanks, part #’s & specs are different for FOB point and are divided by / mark.)

Above Ground - PCO TanksSimplex No.

Part No. Gallon Capacity Tank F.O.B. Diameter/Width Height Length Fill Opening

WP1 1090000W94301 30 Gal. PCO L,P,C 19” 22.5” 24.5” 6”WP2 1170000W94301 50 Gal. PCO L,P,C 19” 22.5” 38” 6”WP3 1200000W94301 100 Gal. PCO L,P,C 30” 31” 38” 10”WP4 1570000W94301 150 Gal. PCO L,P,C 36” 29” 48” 10”WP5 1660000W94301 200 Gal. PCO L,P,C 37” 39.5” 48” 10”WP6 1720000W94301 300 Gal. PCO C 38” 36.75” 69” 18”

Horizontal Leg Tank

Free Standing Water ClosetsSimplex No. Part No. Gallon Capacity Tank F.O.B. Width Height Depth Fill Opening Drain

WC1 1001610W94301 300 Gallon C,M,P 60” 56” 29” 18” 2” B.O.WC2 1001710W94301 400 Gallon C,M,P 60” 71” 29” 18” 2” B.O.

Note: Tanks on pages 7, 8 and 9 are for above ground only.

WH11 1440000W94302 1025 Leg Tank A 48” 50” 139” 18” 2” 45300003*WH12 1000700W94301 1650 Elliptical Leg M,C,P 71” 55” 142” 18” 3” 45800003*WH13 1002300W94301 2000 Ellipitcal Leg P,C 84” 55” 142” 18” 3” 45800007*

9

Page 10: On-Site Septic & Water TanksIts low-profile design is ideal where bedrock, or other factors which restrict hole depth, limit the ability or accessibility to install any other septic

KEY FOR TANK AVAILABILITY: A = All locations • C = Chowchilla, CA • L = Lincoln, NE • M = Marked Tree, AR • P = Philippi, WV KEY FOR TANK AVAILABILITY: A = All locations • C = Chowchilla, CA • L = Lincoln, NE • M = Marked Tree, AR • P = Philippi, WV

SimplexNumber Part No. Color

GallonCapacity

TankF.O.B. Diameter Height

FillOpening

FittingPackage

WB12WG12

1540400W942011540400W99801

BlackGreen

205 Vertical CC

42” 43” 10” BB

WB23WG23

8040000W942018040000W99801

BlackGreen

300 Low Vertical M M

46” 48” 18” AA

WB21 WG21

1630000W9---- 1630000W99802

Black Green

300 Vertical M M

35” 78” 18” A A

WB22 WG22

1630100W94202 1630100W99802

Black Green

300 Vertical C C

36” 82” 18” B B

WB24R WG24R

1008200W94201 1008200W99801

Black Green

330 Vertical C C

47” 50” 18” B B

WB31R WG31R

1009600W94201 1009600W99801

Black Green

500 Vertical C C

47” 77” 18” B B

WB32WG32

8060000W942028060000W99801

BlackGreen

550 Vertical MM

64” 46” 18” AA

WB33WG33

1820000W942021820000W99802

BlackGreen

550 Vertical CC

64” 46” 18” AA

WB41R WG41R

1008600W94202 1008600W99802

Black Green

1000 Vertical C C

72” 64 3/4” 18” B B

WB40R WG40R

1013300W94201 1013300W99801

Black Green

1025 Narrow Vertical M M

60” 95 1/2” 18” A A

WB42WG42

1710100W942021710100W99801

BlackGreen

1100 Vertical LL

86” 53” 18” AA

WB43WG43

8120000W942028120000W99801

BlackGreen

1100 Vertical MM

86” 55” 18” AA

WB44WG44

1710200W942031710200W99804

BlackGreen

1100 Vertical CC

86” 53” 18” BB

WB44R WG44R

1008800W9420-- 1008800W99802

Black Green

1200 Extra Wide Vertical C C

102” 46” 18” B B

WB48R WG48R

1007400W94201 1007400W99802

Black Green

1300 Vertical C C

72” 82” 18” B B

WB45WG45

1770100W942031770200W99801

BlackGreen

1500 Vertical LL

86” 70” 18” AA

WB46WG46

1770300W942041770300W99803

BlackGreen

1500 Vertical CC

86” 70” 18” BB

WB47WG47

8120100W942018120100W99801

BlackGreen

1500 Vertical MM

86” 70” 18” AA

WB49R WG49R

1008900W942-- 1008900W99802

Black Green

1600 Wide Vertical C C

102” 58” 18” B B

WB60WG60

5090100W942015090100W99801

BlackGreen

2500 Vertical LL

90” 106” 18” AA

WB61WG61

8140000W942018140000W99801

BlackGreen

2500 Vertical MM

90” 106” 18” AA

WB61RWG61R

102300W942--102300W998--

BlackGreen

2500 Vertical M M

102” 85 1/2” 18”” A A

WB62WG62

5090200W942045090200W99804

BlackGreen

2600 Vertical CC

96” 89” 24” BB

WB70WG70

7410100W942037410100W99802

BlackGreen

3000 Vertical LL

102” 96” 18” AA

WB71WG71

8390000W942018390000W99801

BlackGreen

3000 Vertical MM

102” 96” 18” AA

Black & Green WATER STORAGE TANKS* *THESE TANKS COME WITH

A 3 YEAR WARRANTY*

10

Page 11: On-Site Septic & Water TanksIts low-profile design is ideal where bedrock, or other factors which restrict hole depth, limit the ability or accessibility to install any other septic

KEY FOR TANK AVAILABILITY: A = All locations • C = Chowchilla, CA • L = Lincoln, NE • M = Marked Tree, AR • P = Philippi, WV

Water Tank Fittings and AccessoriesPart No. Description

34300006 1” Double-threaded poly pro fitting (bulkhead)34100131 1” Double-threaded polyethylene fitting (bulkhead) - Heavy Duty34300003 1 1/4” Double-threaded poly pro fitting (bulkhead)34300008 1 1/2” Double-thread poly pro fitting (bulkhead)34100144 1 1/2” Double-threaded polypropylene fitting (bulkhead) - Heavy Duty34100104 2” Double-threaded polypropylene fitting (bulkhead)34700840 2” Polypropylene fitting with siphon tube (bulkhead)31300120 3” Double-threaded polyethylene fitting (bulkhead)34700539 3” Double-threaded polypropylene fitting with siphon tube (bulkhead)34100103 2” Double-threaded polypropylene fitting (bolt-on)34700842 2” Polypropylene fitting with siphon tube (bolt-on)34100105 3” Double-threaded polypropylene fitting (bolt-on)34700844 3” Double-threaded polypropylene fitting with siphon tube (bolt-on)35300002 4” Stainless steel bolted fitting, full nipple (Chowchilla, only)34700014 J-bolt package of 4 (one package required with each HLT ordered with bands)34300047 6” Threaded cap34300080 10” Threaded cap34300012 18” Threaded lid assembly34700352 24” Threaded lid assembly

11

SimplexNumber Part No. Color

GallonCapacity

TankF.O.B. Diameter Height

FillOpening

FittingPackage

WB73WG73

7410200W992037410200W99803

BlackGreen

3000 Vertical CC

102” 93” 24” BB

WB72WG72

5130200W942055130200W99804

BlackGreen

3000 Vertical CC

96” 109” 24” BB

WB75R WG75R

1009100W942-- 1009100W99802

Black Green

4100 Vertical C C

102” 124 1/4” 24” B B

WB80WG80

7420000W942017420000W99801

BlackGreen

4700 Vertical LL

102” 142 1/2” 18” AA

WB81WG81

8210000W942018210000W99801

BlackGreen

5000 Vertical MM

102” 153” 18” AA

WB83WG83

7420100W942077420200W99804

BlackGreen

5000 Vertical CC

102” 157” 24” BB

WB84WG84

7000200W942057000200W99804

BlackGreen

5000 Low Vertical CC

144” 87” 24” BB

WB100WG100

5330200W942055330200W99804

BlackGreen

10,000 Vertical CC

144” 161” 24” BB

WB101WG101

5330000W942025330000W99801

BlackGreen

10,500 Vertical L,P L,P

142” 169 3/4” 24” BB

Black & Green WATER STORAGE TANKS*

*THESE TANKS COME WITH A 3 YEAR WARRANTY*

Page 12: On-Site Septic & Water TanksIts low-profile design is ideal where bedrock, or other factors which restrict hole depth, limit the ability or accessibility to install any other septic

KEY FOR TANK AVAILABILITY: A = All locations • C = Chowchilla, CA • L = Lincoln, NE • M = Marked Tree, AR • P = Philippi, WV KEY FOR TANK AVAILABILITY: A = All locations • C = Chowchilla, CA • L = Lincoln, NE • M = Marked Tree, AR • P = Philippi, WV

WARRANTYSnyder warrants that if any manufactured tanks product is proven to be defective in material or workmanship within three (3) years from the date of manufacture, five (5) years from the date of manufacture for the Dominator, Snyder will (at company option) either replace or repair said part. This standard limited warranty does not apply to damages resulting from misuse, improper application of recommended materials, accident, or improper installation or maintenance. Remedy to the buyer is limited to the replacement of any defective product (or its component, where applicable), F.O.B. point of manufacture. The buyer’s remedy under this warranty does not include any other direct or consequential damages which result from defects in material or workmanship of its products.

Fitting Package Legend for Black and Green Water Tanks:

Pkg. “A” = Bottom Fitting - One 2” bolt-on fitting with siphon (P/N 34700842) Top Fitting - One 1 1/2” bulkhead fitting (P/N 34000004)

Pkg. “B” = Bottom Fitting - One 2” bolt-on fitting (P/N 34100103) Top Fitting - One 1/2” bulkhead fitting (P/N 34000004)

18” * = 18” is standard, 24” is available for an additional charge.

SAFETY CONSIDERATIONS/CHECKLIST

All tanks must be properly vented. These tanks are not pressure vessels and must be vented to atmosphere. Venting equip-ment should be sized to limit pressure or vacuum in the tank to a maximum of ½” of water.Water tanks have been engineered for the containment or transportation of water ONLY.Continuous operating temperatures above 100 F (38 C) are NOT RECOMMENDED and will void all warranties.Protect tanks from impact (especially sharp blows) HANDLE WITH EXTREME CARE.DO NOT STAND OR WORK ON TOP OF A TANK. Remember, Safety First!

GUIDELINES FOR USE AND INSTALLATIONWATER TANKS

Water Tank Packages & Guidelines

Page 13: On-Site Septic & Water TanksIts low-profile design is ideal where bedrock, or other factors which restrict hole depth, limit the ability or accessibility to install any other septic

KEY FOR TANK AVAILABILITY: A = All locations • C = Chowchilla, CA • L = Lincoln, NE • M = Marked Tree, AR • P = Philippi, WV

GUIDELINES FOR USE AND INSTALLATION

12

Distributed By:

Phone: 402-467-5221 • Fax: 402-465-1220Email: [email protected] • www.snydernet.comCorporate Offices: P.O. Box 4583Lincoln, Nebraska 68504Other Manufacturing Locations: Lincoln, Nebraska • Philippi, West Virginia • Chowchilla, California • Marked Tree, Arkansas

LOCATION REQUIREMENTSA thorough evaluation of the proposed tank location prior to tank installation is recommended. The following several items must be considered prior to placing the tank into service. DO NOT locate the tank in a flood plain or next to equipment that generates heat. Locate the tank so it is easy to install access and maintain. It is the responsibility of the end user to ensure that all location requirements are taken into consideration including all federal, state and local regulations that apply to tank installation. Vertical tanks can be placed on firm, compacted soil that is free of rocks/sharp objects and capable of bearing the weight of the tank and its maximum contents. In addition, a sand or pea gravel base with provisions for preventing erosion is highly recommended. Installation sites for tanks 8,000 gallons or more must be on a reinforced concrete pad providing adequate support and enough space to attach a tank restraint system (anchor using the molded-in tie down lugs with moderate tension, being careful not to over-tighten), especially where seismic or large wind forces are present. The pad should be clean, smooth and level, so it fully supports the entire tank bot-tom with no deflection. Horizontal tanks must be secured with bands and/or hoops to prevent tank movement. CHECK BAND/HOOP TENSION AFTER FILLING TANK. Bands and/or hoops must be tightened to remove all gaps between bands/hoops and tank before and after filling, but not to the degree that there is any tank distortion. Tanks used for transport must have full bottom support and be properly secured to the transport vehicle. DO NOT EXCEED VEHICLE’S GROSS WEIGHT.

TANK ENTRY PRECAUTIONSIf entry into the tank is necessary, be sure to take all necessary precautions and follow all applicable local, state and federal rules and regulations. Entry into the tank should be considered a “CONFINED SPACE ENTRY” with appropriate OSHA safety precautions required. DO NOT enter tank without taking the proper precautions.

TANK FITTINGS AND CONNECTIONSTank fittings are typically left installed in the tank.All tank connections must have adequate provisions for tank expansion/contraction due to temperature and load chang-es and should allow for a 4% dimensional movement. SII strongly recommends the use of expansion joints or other provisions for all tank connections. The use of rigid piping or the failure to provide for the expansion of the tank will void all warranties. After all connections to the tank have been made, fill the tank with water and hold for at least 5 hours to identify any leak(s). Fittings are factory installed—if the fitting leaks first check the tightness of each connection. If the leak persists, inspect the gasket to insure it is fully contacting the tank wall as well as check for damage and proper gas-ket compression. Correct gasket compression should be between 25 and 50%. Recheck fitting tightness periodically.

WATER TANKS