Copyright © 2018 Colliers International. Information herein has been obtained from sources deemed reliable, however its accuracy cannot be guaranteed. The user is required to conduct their own due diligence and verification. John Wadsworth Senior Vice President Healthcare Services License No. 01177404 949 724 5528 [email protected] Aaron Phillips Vice President Healthcare Services License No. 01769480 949 724 5562 [email protected] FOR LEASE | 23961 CALLE DE LA MAGDALENA | LAGUNA HILLS, CA Largest Block of EXISTING Medical Office Space AVAILABLE in Orange County, 26,000 SF+ SADDLEBACK MEDICAL ON-CAMPUS MEDICAL OFFICE Major Building Renovation NOW COMPLETE! For more information or to schedule a property tour, please contact:

Transcript of ON-CAMPUS MEDICAL OFFICE · Mirror: "Bobrick" B-165 Series, 2430, stainless steel bracket. Mount...

Page 1: ON-CAMPUS MEDICAL OFFICE · Mirror: "Bobrick" B-165 Series, 2430, stainless steel bracket. Mount per California Building Code requirements. Grab Bars: "Bobrick" B-5897, single piece,

Copyright © 2018 Colliers International. Information herein has been obtained from sources deemed reliable, however its accuracy cannot be guaranteed.

The user is required to conduct their own due diligence and verification.

John WadsworthSenior Vice PresidentHealthcare ServicesLicense No. 01177404949 724 [email protected]

Aaron PhillipsVice PresidentHealthcare ServicesLicense No. 01769480949 724 [email protected]

FOR LEASE | 23961 CALLE DE LA MAGDALENA | LAGUNA HILLS, CA

Largest Block of EXISTING Medical Office Space AVAILABLE in Orange County, 26,000 SF+

SADDLEBACK MEDICALON-CAMPUS MEDICAL OFFICE

Major Building Renovation NOW COMPLETE!

For more information or to schedule a property tour, please contact:

Page 2: ON-CAMPUS MEDICAL OFFICE · Mirror: "Bobrick" B-165 Series, 2430, stainless steel bracket. Mount per California Building Code requirements. Grab Bars: "Bobrick" B-5897, single piece,

SaddlebackMedical

ParkingGarage

HospitalMOB

Women’sCenter

Saddleback MemorialMedical Center

HospitalExpansion

O�ce

USPost O�ce

CALLE DE LA LOUISA

HEALTH CENTER DR

CALL

E DE

LA

PLAT

A

CALL

E DE

LA

MAG

DALE

NA

PASEO DE VALEN CIA

ParkingStructure

Campus Map

Building Features

> 136,000 SF, five-story medical office building

> Located on campus at Saddleback Memorial Medical Center

> Property complies with CMS site-neutral rule “250 yds from hospital front door”

> Medical space available from 379 SF to 26,000 SF+

> Dedicated structure parking, conveniently located behind building

> Building top signage/branding available for large tenants

> Balanced mix of healthcare specialties, “built-in” referral source

> Directly adjacent to Laguna Woods Village - California Retirement Community

> Easy access to I-5 freeway

> Professionally owned and managed by Greenlaw Partners

Building Renovations Now Complete

> New building signage and wayfinding program

> Extensive lobby upgrades with artwork, planters, and glass wall features

> New loading zone and drop-off area

> New elevator finishes and mechanical improvements

> Modernized HVAC, Mechanical, and Electrical systems

> New FLS/Alarm and Sprinkler Systems

> Updated landscaping

Building Amenities:

> On-site pharmacy

> Multiple lab services

> On-site property management (Suite 440)

SADDLEBACK MEDICAL23961 Calle De La Magdalena | Laguna Hills

The Outpatient Market Scenario Planner (MSP), as developed by the Advisory Board, provides current and projected patient utilization estimates for specific specialties in key markets across the US. The MSP tool supports planners, providers and hospital executives to make intelligent business development and strategic decisions to locate or expand programs in targeted markets. The below data is representative of the South Orange County zip codes that surround Saddleback Medical – which include 92653, 92656, 92691, 92637 & 92630. For more information on the Advisory Board, please visit www.advisory.com.

Patient Demand Forecast, Laguna Hills Market

Colliers International makes no guarantees, representations or warranties of any kind, expressed or implied, regarding the information including, but not limited to, warranties of content, accuracy and reliability. This publication is the copyrighted property of Colliers International and/or its licensor(s). 2018. All rights reserved.

Colliers International makes no guarantees, representations or warranties of any kind, expressed or implied, regarding the information including, but not limited to, warranties of content, accuracy and reliability. This publication is the copyrighted property of Colliers International and/or its licensor(s). 2018. All rights reserved.

SERVICE LINES

TODAY’S VOLUME

5-YearVOLUME

Pulmonology 15,839 20,435 29.0% 23,427 47.9%

Urology 9,595 12,321 28.4% 14,508 51.2%

Ophthalmology 55,941 71,402 27.6% 82,559 47.6%

Neurology 9,143 11,581 26.7% 13,248 44.9%

Pain Management 6,429 8,023 24.8% 9,078 41.2%

Dermatology 34,571 43,021 24.4% 50,165 45.1%

Cosmetic Procedures 4,546 5,646 24.2% 6,193 36.2%

Orthopedics 24,792 30,696 23.8% 34,266 38.2%

Endoscopy 30,073 36,851 22.5% 41,359 37.5%

Podiatry 11,742 14,511 23.6% 17,360 47.8%

Gastroenterology 17,327 21,102 21.8% 23,712 36.8%

Physical Therapy/Rehab 145,695 176,102 20.9% 189,826 30.3%

ENT 18,961 22,884 20.7% 25,947 36.8%

Vascular 8,397 10,106 20.4% 11,740 39.8%

Sleep Studies 15,415 18,346 19.0% 20,378 32.2%

Nephrology 5,171 6,107 18.1% 6,799 31.5%

Ambulatory Surgery 192,877 224,438 16.4% 248,124 28.6%

Psychiatry 75,227 87,067 15.7% 97,566 29.7%

Cardiology 65,233 72,269 10.8% 79,613 22.0%

Oncology 1,322 1,450 9.7% 1,541 16.6%

10-YearVOLUME

2021 2026

Page 3: ON-CAMPUS MEDICAL OFFICE · Mirror: "Bobrick" B-165 Series, 2430, stainless steel bracket. Mount per California Building Code requirements. Grab Bars: "Bobrick" B-5897, single piece,

El Toro Rd.

On Site 292,977Population

$108,844 Average Income

41 Average Age

30.25% Population +55 Yrs Of AgeWithin 5 miles

El Toro Rd.

SADDLEBACK MEDICAL23961 Calle De La Magdalena | Laguna Hills

SADDLEBACK MEMORIAL MEDICAL CENTER

The on-campus/walking distance proximity of Saddleback Medical to Saddleback Memorial Medical Center (SMMC) is significant as Memorialcare is one of the premiere providers of healthcare in Orange County. SMMC is a 325 licensed bed hospital that accounts for 1,978 full time employees. MemorialCare offers a comprehensive mix of specialties in prevention, diagnosis and treatment of cancer, heart disease, stroke, pulmonary disease, orthopedics and diabetes, emergency medicine, breast health, and surgery including robotic-assisted procedures, advanced imaging, women’s health and geriatric care. At present, the MemorialCare Health System consists of 6 hospitals and numerous outpatient health centers, imaging centers throughout the Southland (Orange County and Los Angeles County).

SADDLEBACKMEDICAL

(Major Renovations Underway)

FIVELAGUNAS

Future

Calle de la Plata

Colliers International makes no guarantees, representations or warranties of any kind, expressed or implied, regarding the information including, but not limited to, warranties of content, accuracy and reliability. This publication is the copyrighted property of Colliers International and/or its licensor(s). 2018. All rights reserved.

Colliers International makes no guarantees, representations or warranties of any kind, expressed or implied, regarding the information including, but not limited to, warranties of content, accuracy and reliability. This publication is the copyrighted property of Colliers International and/or its licensor(s). 2018. All rights reserved.

Page 4: ON-CAMPUS MEDICAL OFFICE · Mirror: "Bobrick" B-165 Series, 2430, stainless steel bracket. Mount per California Building Code requirements. Grab Bars: "Bobrick" B-5897, single piece,

First Floor Plan

102

153

119

130MAIN

100

MAIL

MEN'S

143

SHUT-OFF

WOMEN'S

MAIN WATER

DOORHALF HEIGHT

HALF HEIGHTDOOR

THERAPHY

POOL

ELEC

23961 CALLE DE MAGDALENALAGUNA HILLS, CA 92653

1st FLOOR

06/17/16

IMAGING

DENTISTRY

PODIATRY

PHARMACY

PROSTHETICS &ORTHOTICS

AQUATICPHYSICALTHERAPY

113

153

SADDLEBACK MEDICAL23961 Calle De La Magdalena | Laguna Hills

Colliers International makes no guarantees, representations or warranties of any kind, expressed or implied, regarding the information including, but not limited to, warranties of content, accuracy and reliability. This publication is the copyrighted property of Colliers International and/or its licensor(s). 2018. All rights reserved.

Second Floor Plan

Colliers International makes no guarantees, representations or warranties of any kind, expressed or implied, regarding the information including, but not limited to, warranties of content, accuracy and reliability. This publication is the copyrighted property of Colliers International and/or its licensor(s). 2018. All rights reserved.

TELE/ELEC

230

229

231

243

232

23961 CALLE DE MAGDALENALAGUNA HILLS, CA 92653

2nd FLOOR

06/17/16

14,275 SF

LAB

ORTHOPEDICS

IMAGING

SURGEON

217205207

200

220

225

Available SuitesSuite # Size

113 1,090 SF

153 1,981 SF

(Occupied)

Available SuitesSuite # Size

200 2,628 SF

205 1,909 SF

207 1,180 SF

217 2,733 SF

220 3,134 SF

225 1,394 SF

232 2,691 SF

PSYCHIATRY

232

Page 5: ON-CAMPUS MEDICAL OFFICE · Mirror: "Bobrick" B-165 Series, 2430, stainless steel bracket. Mount per California Building Code requirements. Grab Bars: "Bobrick" B-5897, single piece,

TELE/ELEC

WOMEN'S

JAN STG

MEN'S

420

430

426

445

429

431

412

424

23961 CALLE DE MAGDALENALAGUNA HILLS, CA 92653

4th FLOOR

06/17/16

OTOLARYNGOLOGY INTERNALMEDICINE

DENTISTRY

DERMATOLOGYSKIN CARE HOSPITAL NEUROLOGY

402

424

400

PROPERTY MGMTOFFICE

445

Third Floor Plan

SADDLEBACK MEDICAL23961 Calle De La Magdalena | Laguna Hills

Fourth Floor Plan

TELE/ELEC

STG

ENGINEER'SOFFICE

303

305

300

347

333

321

23961 CALLE DE MAGDALENALAGUNA HILLS, CA 92653

3rd FLOOR

06/17/16

GERIATRICS

332

355 351

317

333

307

334

300

Shell

Colliers International makes no guarantees, representations or warranties of any kind, expressed or implied, regarding the information including, but not limited to, warranties of content, accuracy and reliability. This publication is the copyrighted property of Colliers International and/or its licensor(s). 2018. All rights reserved.

Colliers International makes no guarantees, representations or warranties of any kind, expressed or implied, regarding the information including, but not limited to, warranties of content, accuracy and reliability. This publication is the copyrighted property of Colliers International and/or its licensor(s). 2018. All rights reserved.

Available SuitesSuite # Size

400 3,937 SF

402 1,803 SF (Spec Suite)

417 2,187 SF

424 829 SF

445 1,382 SF

Fully Improved New Spec Suite Coming Sept. 2018

+ 60

"

(US

B)

(US

B)

(US

B)

(US

B)

(US

B)

(USB)

(copier)

(USB)

(US

B)(U

SB)

(US

B)

(US

B)

(US

B)

(alt.

cop

ier

loca

tion)(H

)

(H)

(H) (

gfci

)(+

48")

(H) (

gfci

)(+

48")

(H)

(H)

(+48

")(+

48")

(H) (

gfci

)(+

48")

(+48

")(H

)

(H)

(H) (

gfci

)(+

48")

(+48

")(H

) (gf

ci)

(+48

")

(+48

")

(H)

(H)

(H)

(H)

(USB)(+48")

(USB)(+48")

(+86")

(US

B)

(US

B)

(+86" t.v.)

(USB)

(+40

")(g

fci)

1 Scale: 1/4" = 1'-0"

Preliminary Prcing Plan - Partitions / Electrical & Data Locations

DATEISSUE

TEN

AN

T IM

PR

OV

EM

EN

T FO

R:

Consultants

California

email: [email protected]

Lagu

na H

ills,

CA

926

5323

961

Cal

le D

e La

Mag

dale

na

(~ 1

,803

rent

able

squ

are

feet

)

Sui

te 4

02

1

NEW GYP. BD. AND 3-5/8" STEEL STUD FRAMING PARTITION WITH ROXUL SOUND BATTINSULATION TO UNDERSIDE OF ACOUSTICAL CEILING.

EXISTING PARTITION TO REMAIN. (ALSO EXTERIOR BUILDING STRUCTURE)

NEW MILLWORK WITH PLASTIC LAMINATE AND/OR SOLIDSURFACE MATERIAL.

VOICE/DATA OUTLET WITH 1" DIAM. CONDUIT TO 6" ABOVE WALL TOP TERMINATIONOR 6" ABOVE ACOUSTICAL CEILING TILE IF ON FULL-HEIGHT WALL.

DUPLEX OUTLET AT +18" A.F.F. UNLESS OTHERWISE NOTED.PROVIDE HOSPITAL GRADE OUTLETS WITH REDUNDANT GROUNDED CABLE PER NECAND CEC ARTICLE 517 IN PATIENT TREATMENT ROOMS AS INDICATED WITH (H).

DEDICATED DUPLEX OUTLET AT 18" A.F.F. UNLESS OTHERWISE NOTED.

TRANSITION STRIP BETWEEN CARPET / RESILIENT FLOORING OR BETWEEN RESILIENTFLOORING AND FLOORING OF ANOTHER THICKNESS.

DATA OUTLET.

NEW 5'-4" HIGH LOW PARTITION w/ 'ROXUL' SAFE-N-SOUND BATT INSULATION, w/WOOD TOP CAP TO MATCH DOOR FINISH, PAINT REVEAL BETWEEN WOOD CAP ANDPAINTED WALL BELOW, PAINT TO MATCH ACCENT WALL.

LEGEND

NEW GYP. BD. AND STEEL STUD FRAMING PARTITION WITH ROXUL SOUND BATTINSULATION TO 6" ABOVE NEW GYP. BD. CEILING. (RESTROOMS)

DUPLEX OUTLET WITH (2) USB CHARGING PORTS @ +18" A.F.F UNLESS OTHERWISENOTED.

(USB)

NEW DEMISING PARTITION TO UNDERSIDE OF STRUCTURE ABOVE. 3-5/8" STEEL STUDS@ 24" O.C. 5/8" TYPE 'X' GYP. BD. EACH SIDE OF STUDS, 'ROXUL' SAFE-N-SOUND BATTINSULATION IN WALL CAVITY.

DEDICATED QUAD OUTLET AT 18" A.F.F. UNLESS OTHERWISE NOTED.

DEDICATED QUAD OUTLET AT 18" A.F.F. UNLESS OTHERWISE NOTED.

TELEVISION / CABLE(tv)

Provide new exhaust fan.

Provide new acoustical ceiling and grid.

Provide Semi-recessed trash receptacle: "Bobrick"B-43644 with LinerMate trash liner holder. Mount top ofunit (not flange) @ 38" a.f.f.

Provide new gyp. bd. soffit w. radiused corner bead @ 7'-9" a.f.f.

Provide new 4' x 4' x 3/4" fire treated plywood with lable showing. paint to match walls but do notpaint over label. Dedicated circuit 30 A. quad outlet. 4" diam. sleeve.

Provide new Coat Hooks where shown (with backing plate where shown). "BOBRICK" 76727classic double robe. Brushed stainless steel finish. Mount @ +40" a.f.f. inside Exam. Room door.

Provide approx. 6'-6" feet of plas. lam. cabinetry. 8'-6" high with 4" toe kick, plas. lam.doors. 18" deep with 7 adjustable shelves with earthquake clip shelf pins each. Divide intoapprox. 3 sections with pair of doors and wire pull handles each. Anchor to wall withmedium weight anchors and adequate backing.

Provide new blade type supply and return diffusers / grilles throughout.

Ceiling height 9'-0".

Provide plas. lam. counter w/ waterfall front edge, integral radiused splash, upper and lowercabinetry, base cabinet with single drawer, door below with single adjustable shelf. AWI "customgrade" quality - No exception. See plumbing schedule for plumbing and faucet.

Furniture and equipment is shown for general suggested layout and to show approachclearances to doors are adequate.

Construction Key Notes (notes in circles on plans)

Restroom:

Wall hung lavatory and faucet: See plumbing schedule.

Toilet: See plumbing schedule.

Accessories:Mirror: "Bobrick" B-165 Series, 2430, stainless steel bracket. Mount per California

Building Code requirements.

Grab Bars: "Bobrick" B-5897, single piece, two-wall toilet compartment bar. 1-1/4" diam. stainless steel with snap flange.(Alternate:) Separate side and rear grab bars. Contractor must meet mountingrequirements for mounting heights, clearances and distances from plumbing fixtures.

* Contractor to provide for a minimum of 250 lb. point load and support backing to meet thatrequirement.

Coat Hook: "Bobrick" B-6727, satin-finish stainless steel double robe hook. Mount per California Building Code requirements centered on the inside of the restroom door.

Soap Dispenser: "Bobrick"

Toilet Roll Disp.: "Bobrick" B-2888, surface mounted. Mount per Calif. Bldg. Code requirements.

Toilet SeatCover Disp.: "Bobrick" B- , surface mounted. Mounting height per Calif. Bldg. Code requ.

Paper TowelDispenser /Waste Recept.: "Georgia Pacific" 59491 Recessed trash receptacle, Automatic paper towel

dispenser, stainless steel.(Alternate 1):

(Alternate 2):

Spec SuiteSuite 40223961 Calle de la MagdalenaLaguna Hills, CA 92653SRB Design Project Name: Spec Suite 402SRB Design Project Number: 18-0123Space Plan Date: 1-26-18Space Plan Reference: SP 1.1.2Prepared by: Scott BrunnerReviewed by: -

General Pricing Notes:A. General Contractor shall provide for the following:

- Fire and Life Safety alarms and strobe light design and installation.- Provide documented compliance with California Green Building Code.- Provide for documented compliance for Asbestos and Lead Paint survey and remediation requirements.- Provide compliance with the following codes:

- California Building Code: Latest edition used by the City of Laguna Hills.- California Mechanical Code: Latest edition adopted by the City of Laguna Hills.- California Electrical Code: Latest edition adopted by the City of Laguna Hills.- California Plumbing Code: Latest edition adopted by the City of Laguna Hills.- California Fire Code: Latest edition adopted by the Orange County Fire Authority and the City of Laguna Hills.- California Green Building Code (GC): Latest edition adopted by the City of Laguna Hills.- California Title 24 Energy Standards (T-24): Latest edition adopted by the City of Laguna Hills.- Building Efficiency Standards (BEES): Latest edition adopted by the City of Laguna Hills.

- M.E.P. Engineering design shall be provided by Landord approved Tenant design professional.

- This building uses ducted return air and Fan Coil units. Mechanical design andconstruction must coordinate with Building Engineer for compliance with FLS System in this building.

B. Remove all existing flooring throughout and prepare for new finishes. Provide asbestos reportprior to removal of any finishes.

C. Remove walls, cabinetry and plumbing as shown. Contractor to walk the site prior toproviding preliminary pricing.

D. Remove all unused communications wiring or other low voltage wiring including all located inthe plenum space.

E. Remove and terminate all un-used or un-relocated circuits.E. Re-use existing electrical circuiting where possible.F. All patient treatment rooms require Hospital Grade redundant grounded electrical outlets

per CEC Article 517. Verify if the building is equipped with this wiring and, if not, providedesign to provide for the requirement for redundant grounding at electrical outlets in PatientTreatment Rooms below 7 feet a.f.f. Where existing electrical is located within 7' of water,change to GFCI outlets. General Contractor and / or Electrical Sub-Contractor to walk thejob site prior to demolition and qualify any findings in Preliminary Pricing quote anddocument any findings outside the scope of ordinary electrical construction.

G. General Contractor and / or Electrical Sub-Contractor to walk the job site prior to demolitionand determine existing capacity of electrical service to this suite and be prepared to includeany sub-panels, if required, in new design and qualify their Preliminary Pricing quote.

H. Provide new acoustical ceiling tiles and grid throughout. Provide new acoustical ceiling gridthroughout as shown. Provide "BERC" clips, compression posts and other seismic lay-inacoustical ceiling panel construction throughout unless otherwise noted.

I. Light switches and electrical outlets throughout are to match the existing building standardcolor. Match where new construction occurs.

J. Provide new lighting controls for compliance with 2016 California Electrical Code and CA Title24 Energy requirements.

J.A. Provide building Standard Luminaires: New xxxxxx LED luminaires with appropriatelighting controls per Title 24.

J.B. Exterior window zone lighting controls:J.C. Interior room lighting controls:

K. Existing electrical outlets are building standard with building standard cover plates.K.A. Mfr.:K.B. Color:

L. Paint the suite with 2 coats of color(s) selected throughout.M. General Contractor to verify HVAC supply and return systems and exhaust system in the field.

Verify that Mechanical design can be accommodated.N. This suite is in a fully sprinkled building. Contractor to provide sprinkler design and permits.Q. Provide building standard “Watts flood safe” fittings on all sinks and toilets in patient

treatment areas and restrooms. Not required in Processing Room.R. Provide new doors throughout except where suite entry doors are existing to remain. Provide new "Haley Bros." Plain Sliced White Birch, clear finish. "Timely" alumatone finish or

(match building standard).S. Provide HVAC duct, return air grilles and supply air diffusers as required for new configuration

of space. Provide new building standard ducts, diffusers and return air grilles.T. Provide new corner guards on all exposed corners. See specifications in keynotes "Acrovyn"

4000 series, surface mounted to + 48" a.f.f. mounted above the rubber base.U. Provide new 12" stainless steel kickplates on push side of all doors unless otherwise noted.W. All voice/data and data drops by Tenant. Contractor to provide pull-box and 1" diameter

conduit to 6" above walls with pull string. Provide new power and data outlets as shown.V. Where called for as locksets, use the building standard lever handle, brushed Stainless Steel,

"Schlage" keyway, cylindrical door hardware. Re-use hinges. Verify that ball bearing hingesfor fire rated doors are used appropriately. Or match existing building standard lever handlesas long as they comply with current ADA accessibility standards.

W. Furniture shown is provided by tenant and is shown for general layout and exitingcompliance and ADA clearance compliance.

X. All new millwork / casework shown on these plans shall comply with Architectural WoodworkStandards, current edition for "Custom Grade".

Y. Engineering will be provided for the following:AC..A. Electrical Engineering for electrcial and Lighting including Title 24 Energyforms and calculations.AC..B. Plumbing Engineering.AC..C. Mechanical Engineering

Scale: 1/8" = 1'-0"

Preliminary Prcing Plan - Demolition3 Scale: 1/8" = 1'-0"

Preliminary Prcing Plan - Reflected Ceiling2

Provide approx. 5'-0" feet of plas. lam. cabinetry. 4" toe kick, plas. lam. doors. 15" deepupper cabinets with 2 adjustable shelves, earthquake clip shelf pins each shelf. Divide intoapprox. 3 sections with pair of doors and wire pull handles each.

Provide new restroom gyp. ceiling height @ 8'-0".

Provide new special circular blade type supply diffuser in gyp. bd. ceiling.

PS2

PT1

L1

PS2

PS1

PS1

PS1

PS1

CEILING LEGEND

EXHAUST FAN WITH CAPACITY TO PROVIDE 25 / 50 (cfm / unit) MINIMUMEXHAUST RATE. (2013 C.B.C., 1203.4.2.1 AND THE CALIFORNIA MECHANICALCODE). MINIMUM EXHAUST RATE SHALL NOT BE LESS THAN THATESTABLISHED BY TABLE 403.7 "MINIMUM EXHAUST RATES". SEE CALIFORNIAMECHANICAL CODE CHAPTER 5 FOR ADDITIONAL PROVISIONS RELATED TOENVIRONMENTAL AIR DUCTS.

ILLUMINATED EXIT SIGN WITH GREEN or RED LETTERS. WITH 90 MINUTEBATTERY PACK. (CBC 2013, 1006.3.1) (NOTE: CBC 1011.1 EXCEPTION 1: EXITSIGNS ARE NOT REQUIRED FOR ROOMS OR AREAS THAT REQUIRE ONLY ONEEXIT OR EXIT ACCESS.) RELOCATE EXISTING IF ANY ARE ON SITE.

CEILING MOUNTED MOTION DETECTOR CONNETCT TOWALL SWITCH / (MAY ALSO HAVE LIGHT SENSOR - SEEELECTRICAL ENGINEERING)

"eLM" WALL MOUNTED L.E.D. EMERGENCY ILLUMINATION WITH 90MINUTE BATTER PACK. MOUNT IMMEDIATELY BELOW CEILING.

"eLM" CEILING MOUNTED L.E.D. EMERGENCY ILLUMINATION WITH 90MINUTE BATTER PACK.

"dlm" DRD2, 4" , 3500K (or match Kelvin temperature of building standard 2'x4'luminaires), DIMMABLE TO 5%, LED RECESSED DOWNLIGHT. 750 LUMEN. NON ICRATED.

BUILDING STANDARD WALL MOUNTED OCCUPANCYSENSOR DIMMER SWITCH.

NEW GYPSUM BOARD CEILING (or SOFFIT)

NEW BUILDING STANDARD 13/16" INVERTED 'T' BARACOUSTICAL CEILING TILE, w/ "BERC" CLIPS,COMPRESSION POSTS, ETC. "ARMSTRONG" ORAPPROVED EQUIVALENT. SPECIFIC LOCATIONS NOT YETDETERMINED. "ARMSTRONG" SECOND LOOK 2'x4'ACOUSTICAL CEILING TILES.

BUILDING STANDARD 2' x 2' SUPPLY AIR DIFFUSER withBLADE GRILLE. (SPECIFIC QUANTITY AND LOCATION TOBE DETERMINED BY MECHANICAL ENGINEERING - NOTYET PROVIDED)

BUILDING STANDARD 2' x 2' DUCTED RETURN AIR wtihBLADE GRILLE.(SPECIFIC QUANTITY AND LOCATION TO BE DETERMINEDBY MECHANICAL ENGINEERING - NOT YET PROVIDED)

New 2' x 4' Building Standard LED luminaire.

New 2' x 2' Building Standard LED luminaire.

New 2' x 2' Building Standard LED luminaire in gyp. bd. ceiling with drywall adapter.

Separate "Georgia Pacific" enMotion automatic papertowel dispenser, separate semi-recessed "Bobrick" (orapproved equivalent) waste receptacle only. Both tobe mounted so as to not impinge on disabled accesscodes.

DIMMING SWITCH WITH MOTION SENSOR FOR RECESSEDDOWNLIGHTS.

D

Non-Standard circular bladed supply air grille in gyp.bd. ceiling condition.

Provide 12" plas. lam. counter top without splash. Storage doors and adjustable shelvesbelow.

Provide 24" deep plas. lam. counter top w/"Speed Brace" support corbels. Provide for 3"diam. grommets as identified by tenant in thefield.

Provide 15" deep plas. lam. upper cabinets w/(2) adjustable shelves and seismic shelf pins.

Provide 8' high x 12" deep plas. lam. cabinetwith upper pair of doors and lower pair ofdoors for copier and paper supplies.

Provide 8' high x 20" deep plas. lam. cabinetwith pair of upper doors for access totelephone equipment / backboard and lowerpair of doors for access to (2) adjustableshelves.

NEW 4" DIAM. CONDUIT SLEEVE EXTENDING 6" ABOVE CEILING AND 6" BELOW CEILINGFOR DATA / COMPUTER NETWORKING.

Provide 20" deep plas. lam. counter top withend panel @ 30" a.f.f. Provide (1) "SpeedBrace" support corbel if required in the center.Provide (2) grommets for wire management.

Provide 12" deep Solid Surface transactioncounter with 1-1/2"

1. Eased edges or2. Bullnose edge.

Provide Solid Surface 24" deep work counterwith 1-1/2"

1. Eased edges or Bullnose edge.2. Gyp. bd. low parition.3. Peninsula table top with single 4" diam.

table leg centered.

Provide 18" wide file pedestal. (2) box drawers,(1) file drawer. Do not use pedestal for supportof counter top.

Provide base and upper plastic laminatecabinets, counter with integral splash. Uppercabinets are to have deeper area formicrowave oven counter. Base cabinets havesingle drawer with door and single adjustableshelf below counter. 50% of upper and lowercabinets are to be within the reach ranges fordisabled persons per the last edition of theCalifornia Building Code.

Scale(Vitals)

Provide backing for tenant supplied televisionwall mounting bracket.

1,803 SF

Available SuitesSuite # Size

300 12,493 SF

307 4,970 SF

317 4,752 SF

333 1,425 SF

347 1,425 SF

351 1,656 SF

355 1,171 SF

(Divisible)

347

417

Page 6: ON-CAMPUS MEDICAL OFFICE · Mirror: "Bobrick" B-165 Series, 2430, stainless steel bracket. Mount per California Building Code requirements. Grab Bars: "Bobrick" B-5897, single piece,

Available SuitesSuite # Size

501 2,324 SF

504 2,485 SF

510 1,809 SF

530 5,377 SF

Fifth Floor Plan

TELE/ELEC

STG

520504

503 517519

23961 CALLE DE MAGDALENALAGUNA HILLS, CA 92653

5th FLOOR

IVF GERIATRICS

SLEEPMEDICINE510 504

SADDLEBACK MEDICAL23961 Calle De La Magdalena | Laguna Hills

Building Photos

Colliers International makes no guarantees, representations or warranties of any kind, expressed or implied, regarding the information including, but not limited to, warranties of content, accuracy and reliability. This publication is the copyrighted property of Colliers International and/or its licensor(s). 2018. All rights reserved.

Colliers International makes no guarantees, representations or warranties of any kind, expressed or implied, regarding the information including, but not limited to, warranties of content, accuracy and reliability. This publication is the copyrighted property of Colliers International and/or its licensor(s). 2018. All rights reserved.

UROLOGY

DERMATOLOGY

530 501

Page 7: ON-CAMPUS MEDICAL OFFICE · Mirror: "Bobrick" B-165 Series, 2430, stainless steel bracket. Mount per California Building Code requirements. Grab Bars: "Bobrick" B-5897, single piece,

Accelerating success.This document has been prepared by Colliers International for advertising and general information only. Colliers International makes no guarantees, representations or warranties of any kind, expressed or implied, regarding the information including, but not limited to, warranties of content, accuracy and reliability. Any interested party should undertake their own inquiries as to the accuracy of the information. Colliers International excludes unequivocally all inferred or implied terms, conditions and warranties arising out of this document and excludes all liability for loss and damages arising there from. This publication is the copyrighted property of Colliers International and/or its licensor(s). ©2017. All rights reserved.

John WadsworthSenior Vice PresidentLicense No. 01177404949 724 [email protected]

Aaron PhillipsVice PresidentLicense No. 01769480949 724 [email protected]

Colliers International3 Park Plaza | Suite 1200

Irvine, CA 92614P: +1 949 724 5500 F: +1 949 724 5600

For more information or to schedule a property tour, please contact: