OIL WELL POTENTIAL TEST, COMPLETION OR RECOMPLETION …
Transcript of OIL WELL POTENTIAL TEST, COMPLETION OR RECOMPLETION …
RAILROAD COMMISSION OF TEXAS1701 N. Congress
P.O. Box 12967Austin, Texas 78701-2967
OIL WELL POTENTIAL TEST, COMPLETION OR RECOMPLETION REPORT, AND LOG
Form W-2Status:Date:Tracking No.:
06/01/2017
Approved
165482
OPERATOR INFORMATION
WELL INFORMATION
Operator Name:Operator Address:
Operator No.:
FILING INFORMATION
API No.:Well No.:Lease Name:RRC Lease No.:Location:
Latitude:This well is located
which is the nearest town in the county.
Longitude:
Field No.:Field Name:RRC District No.:County:
miles in adirection from
COMPLETION INFORMATION
Purpose of filing:Type of completion:
Type of PermitPermit to Drill, Plug Back, or DeepenRule 37 Exception
Fluid Injection PermitO&G Waste Disposal PermitOther:
Date Permit No.
Spud date:
Date plug back, deepening, recompletion, ordrilling operation commenced:
Number of producing wells on this lease inthis field (reservoir) including this well:
Total number of acres in lease:
Total depth TVD (ft.):
Plug back depth TVD (ft.):
Was directional survey made other thaninclination (Form W-12)?
Recompletion or reclass?Type(s) of electric or other log(s) run:
Multiple completion?
Is Cementing Affidavit (Form W-15) attached?Rotation time within surface casing (hours):
Plug back depth MD (ft.):
Total depth MD (ft.):
reservoir (ft.):Distance to nearest well in lease &
drilling operation ended:Date plug back, deepening, recompletion, or
Date of first production after rig released:
Elevation (ft.):
05/22/2016
JAGGED PEAK ENERGY LLC 4295741125 17TH STREET SUITE 2400 DENVER, CO 80202-0000
42-495-33723 1H
UTL 4344-21
48515 Section: 48, Block: 20, Survey: UL, Abstract: U40
31.66411
WINKLER08
PHANTOM (WOLFCAMP)
71052900
-103.25185
8.4 SW
WINK,
Initial Potential
New Well
81493804/28/2016
05/20/2016 07/06/2016
08/07/2016
1
640.70
11654 21862
Yes
Gamma Ray (MWD)
0.0
2758 GL
40.0Yes
No No
Electric Log Other Description:
Well Type: Producing Completion or Recompletion Date: 08/07/2016
Location of well, relative to nearest lease boundaries Noof lease on which this well is located: 330.0 Feet from the Line andNorth
598.0 Feet from the East Line of the
Lease.UTL 4344-21
Off Lease :
Field & Reservoir Gas ID or Oil Lease No. Well No. Prior Service TypeFORMER FIELD (WITH RESERVOIR) & GAS ID OR OIL LEASE NO.
PACKET: N/A4Page 1 of
Operator is correcting spud date to 4/13/16
W2: N/A
GAU Groundwater Protection Determination
SWR 13 Exception
FOR NEW DRILL OR RE-ENTRY, SURFACE CASING DEPTH DETERMINED BY:Depth (ft.): Date:
Depth (ft.):
650.0 04/13/2016
INITIAL POTENTIAL TEST DATA FOR NEW COMPLETION OR RECOMPLETIONDate of test:Number of hours tested:Was swab used during this test?
Oil (BBLS):Gas - Oil Ratio:
Gas (MCF):Oil (BBLS):
Flowing Tubing Pressure:
Gas (MCF):
Oil produced prior to test:Choke size:Production method:
Oil Gravity - API - 60.:Water (BBLS):
PRODUCTION DURING TEST PERIOD:
CALCULATED 24-HOUR RATE
Water (BBLS):
Casing Pressure:
09/06/2016 Flowing
24 32No 21739.34
1505.08
3681
1534
2839.00
1505.1
40.6
3681
15342325.00
1019
CASING RECORD
Row
CasingSize(in.)
Type ofCasing
HoleSize(in.)
SettingDepth
(ft.)
Multi -Stage ToolDepth (ft.)
Multi -Stage ShoeDepth (ft.)
CementClass
CementAmount(sacks)
SlurryVolume(cu. ft.)
Top ofCement
(ft.)
TOCDetermined
By1 Surface 13 3/8 17 1/2 761 C 610 1132.3 Circulated to Surface0
2 Intermediate 9 5/8 12 1/4 7745 C & H 1435 3860.3 Calculation0
3 Intermediate 7 8 3/4 12082 C & H 680 2119.0 Calculation0
LINER RECORD
RowLiner
Size (in.)CementClass
CementAmount(sacks)
SlurryVolume(cu. ft.)
Top ofCement
(ft.)TOC
Determined ByHole
Size (in.)Liner
Top (ft.)Liner
Bottom (ft.)1 4 1/2 6 9805 21862 HSLD 87 780 1185.6 Circulated to Surface0
TUBING RECORD
Row Size (in.) Depth Size (ft.) Packer Depth (ft.)/Type
1 3 7/8 10000 /10000
PRODUCING/INJECTION/DISPOSAL INTERVAL
Row Open hole? From (ft.) To (ft.)1 No 21770.0L1 11774
ACID, FRACTURE, CEMENT SQUEEZE, CAST IRON BRIDGE PLUG, RETAINER, ETC.
Row Type of Operation Amount and Kind of Material Used Depth Interval (ft.)
Was hydraulic fracturing treatment performed?
Is well equipped with a downhole actuation
Production casing test pressure (PSIG) prior to
Has the hydraulic fracturing fluid disclosure beenreported to FracFocus disclosure registry (SWR29)?
If yes, actuation pressure (PSIG):
Actual maximum pressure (PSIG) during hydraulic
Yes
Nosleeve?
Yes
fracturing: 10749hydraulic fracturing treatment: 11800
4Page 2 of
1 Fracture 30498966 # 100 MESH, 2396008 # 40/70 OTTAWA, 2193637 #40/70 SANDWEDGE, 70800 GAL 15% HCL, 30933 FDP-S1204-
15, 16568 GAL BE-9, 33522 OIL ENX FDP 1233, 3550 #SANDWEDGE ABC, 12792 MICROSCOUT FDP 1215, 8571
OPTIKLEEN WF, 3690 FDP-S1231-16
2177011774
FORMATION RECORD
Formations Depth TVD (ft.) Depth MD (ft.)Is formation
isolated?Encountered Remarks
RUSTLER - POSSIBLE FLOW;POSSIBLE USABLE QUALITY W
725.0 Yes725.0 CASEDYes
COLBY-QUEEN 2900.0 Yes2900.0 CASEDYes
YATES 2280.0 Yes3200.0 CASEDYes
QUEEN-SEVEN RIVERS 2700.0 Yes2700.0 CASEDYes
SAN ANDRES - HIGH FLOWS, H2S,CORROSIVE
3600.0 Yes3600.0 CASEDYes
HOLT 4500.0 Yes4500.0 CASEDYes
DELAWARE 5000.0 Yes5000.0 CASEDYes
GLORIETA 5600.0 Yes5600.0 CASEDYes
CLEARFORK 6200.0 Yes6200.0 CASEDYes
WICHITA ALBANY 6600.0 Yes6600.0 CASEDYes
BRUSHY CANYON 7300.0 Yes7300.0 CASEDYes
CHERRY CANYON 7800.0 Yes7800.0 CASEDYes
CANYON 8400.0 Yes8400.0 CASEDYes
BONE SPRINGS 9000.0 Yes9000.0 CASEDYes
MONTOYA 10300.0 Yes10300.0 CASEDYes
WADDELL 11000.0 Yes11000.0 CASEDYes
WOLFCAMP 11450.0 No11513.0 PRODUCING ZONEYes
ATOKA No NOT DRILLED TO THISDEPTH
No
STRAWN No NOT DRILLED TO THISDEPTH
No
PENNSYLVANIAN No NOT DRILLED TO THISDEPTH
No
MISSISSIPPIAN No NOT DRILLED TO THISDEPTH
No
DEVONIAN No NOT DRILLED TO THISDEPTH
No
SILURIAN No NOT DRILLED TO THISDEPTH
No
FUSSELMAN No NOT DRILLED TO THISDEPTH
No
ELLENBURGER No NOT DRILLED TO THISDEPTH
No
Do the producing interval of this well produce H2S with a concentration in excess of 100 ppm (SWR 36)?
Is the completion being downhole commingled (SWR 10)?
No
No
REMARKS
4Page 3 of
RRC REMARKS
[RRC Staff 2016-12-30 11:38:20.719] EDL=9996 feet, max acres=704, PHANTOM (WOLFCAMP) oil or gas well
PUBLIC COMMENTS:
CASING RECORD :
TUBING RECORD:
PRODUCING/INJECTION/DISPOSAL INTERVAL :
ACID, FRACTURE, CEMENT SQUEEZE, CAST IRON BRIDGE PLUG, RETAINER, ETC. :
POTENTIAL TEST DATA:
OPERATOR'S CERTIFICATIONPrinted Name:Telephone No.: Date Certified:
Title:Lauren Walsh Regulatory Specialist
(720) 215-3634 05/23/2017
4Page 4 of
RAILROAD COMMISSION OF TEXASOil and Gas Division
FORM L-1 ELECTRIC LOGSTATUS REPORT
Instructions
When to File Form L-1: Where to File Form L-1:� with the appropriate Commission district office� with Forms G-1, W-2, and GT-1 for new and deepened gas, oil, and
geothermal wells
� with Form W-3 for plugged dry holes� when sending in a log which was held under a request for confidentiality and the period for confidentiality has not yet expired.
Filling out Form L-1:� Section I and the signature section must be filled out for all wells� complete only the appropriate part of Section II
Type of log required:When is Form L-1 NOT required:
� with Forms W-2, G-1, and GT-1 filed for injection wells, disposal wells, water supply wells, service wells, re-test wells, re- classifications, and plugbacks of oil, gas or geothermal wells� with Form W-3 for plugging of other than a dry hole
� any wireline survey run for the purpose of obtaining lithology, porosity, or resistivity information� no more than one such log is required but it must be of the subject well� if such log is NOT run on the subject well, do NOT substitute any other type of log; just select Section II, Part A below
This facsimile L-1 was generated electronically from data submitted to the RRC.
SECTION I. IDENTIFICATIONOperatorName:
District No.
CompletionDate:
Drilling PermitNo.
FieldName
LeaseName
County
Lease/IDNo.
WellNo.
API
No. 42-SECTION II. LOG STATUS (Complete either A or B)
08 08/07/2016
WINKLER
814938PHANTOM (WOLFCAMP)
JAGGED PEAK ENERGY LLC
UTL 4344-21 48515 1H
495-33723
A. BASIC ELECTRIC LOG NOT RUN
B. BASIC ELECTRIC LOG RUN. (Select one)
1. Confidentiality is requested and a copy of the header for each log that has been run on the well is attached.
2. Confidentiality already granted on basic electric log covering this interval (applicable to deepened wells only).
3. Basic electric log covering this interval already on file with Commission (applicable to deepened wells only).
4. Log attached to (select one):
(a) Form L-1 (this form). If the company/lease name on log is different from that shown in Section I, please enter name on log here:
Check here if attached log is being submitted after being held confidential.
(b) Form P-7, Application for Discovery Allowable and New Field Designation.
(c) Form W-4, Application for Multiple Completion:
Well No(s).
Signature Title
Name (print) Phone Date
-FOR RAILROAD COMMISSION USE ONLY-
X
X
X
05/31/2017
Lease or ID No(s).
Regulatory Specialist
(720) 215-3634
Lauren Walsh
JAGGED PEAK ENERGY LLC
Tracking No.: 165482
CERTIFICATE OF COMPLIANCEAND TRANSPORTATION AUTHORITY
P-4RAILROAD COMMISSION OF TEXAS
Oil and Gas Division
PO Box 12967Austin TX 78711-2967www.rrc.texas.gov
1. Field name exactly as shown on proration schedule 2. Lease name as shown on proration schedule
3. Current operator name exactly as shown on P-5 Organization Report 4. Operator P-5 no. 5. Oil Lse/Gas ID no 6. County 7. RRC district
8. Operator address including city, state, and zip code 9. Well no(s) (see instruction E)
PHANTOM (WOLFCAMP) UTL 4344-21
JAGGED PEAK ENERGY LLC 429574 48515 WINKLER 08
1H
10. Classification 11. Effective Date1125 17TH STREET SUITE 2400DENVER, CO 80202
Oil Gas Other (see instruction A)
12. Purpose of Filing. (Complete section a or b below.) (See instructions B and G)a. Change of: operator oil or condensate gatherer gas gatherer gas purchaser gas purchaser system code
field name fromlease name from
OR
b. New RRC Number for: oil lease gas well
other well (specify)Due to: new completion or recompletion
consolidation, unitization, or subdivision (oil lease only)
reclass oil to gas reclass gas to oil
08/07/2016
X
This facsimile P-4 was generated electronically from data submitted to the RRC. A certification of the automated data is available in the RRC's Austin office.
X
X
Tracking No.: 165482
13. Authorized GAS WELL GAS or CASINGHEAD GAS Gatherer(s) and/or Purchaser(s). (See instruction G).
Gat
here
r
Purc
hase
r
Full-
wel
lst
ream
Percent of Take
Name of GAS WELL GAS or CASINGHEAD GAS Gatherer(s) or Purchaser(s) As Indicated in Columns to the Left(Attach an additional sheet in same format if more space is needed)
Purchaser�s RRC AssignedSystem Code
0001OUTRIGGER MIDLAND OPERATING, LLC(628548)X X 100.0
14. Authorized OIL or CONDENSATE Gatherer(s). (See instruction G).
Percent of Take
Name of OIL or CONDENSATE Gatherer(s) - List Highest Volume Gatherer First (Attach an additional sheet in same format if more space is needed)
ORYX SO. DELAWARE OGT LLC(627117) 100.0
RRC USE ONLY: Reviewer�s initials: Approval date:RRC Staff 06/01/2017
15. PREVIOUS OPERATOR CERTIFICATION FOR CHANGE OF OPERATOR P-4 FILING. Being the PREVIOUS OPERATOR, I certify that operatingresponsibility for the well(s) designated in this filing, located on the subject lease has been transferred in its entirety to the above named Current Operator. I understand, as Previous Operator, that designation of the above named operator as Current Operator is not effective until this certificate is approved by the Commission.
Name of Previous Operator Signature
Name (print)Authorized Employeeof previous operator
Authorized agent of previousoperator (see instruction G)
Title Date Phone with area code
16. CURRENT OPERATOR CERTIFICATION. By signing this certificate as the Current Operator, I certify that all statements on this form are true and correct and Iacknowledge responsibility for the regulatory compliance of the subject lease including plugging of well(s) pursuant to Rule 14. I further acknowledge that I assume responsibility for the physical operation, control, and proper plugging of each well designated in this filing. I also acknowledge that I will remain designated as the CurrentOperator until a new certificate designating a new Current Operator is approved by the Commission.
Name (print) Signature
Title
Authorized Employeeof current operator
Authorized agent of currentoperator (see instruction G)
E-mail Address (optional) Date Phone with area code
JAGGED PEAK ENERGY LLC
(720) 215-3628
Connie Mitchell
12/29/[email protected]
X