Cable Socks - Pulling & Supporting Subsea & Offshore Cables & Umbilicals
Offshore Cable
-
Upload
kingdiamond -
Category
Documents
-
view
232 -
download
0
Transcript of Offshore Cable
-
8/10/2019 Offshore Cable
1/96
OFFSHORE
CABLES
-
8/10/2019 Offshore Cable
2/96
-
8/10/2019 Offshore Cable
3/96
FOREWORD
ONE OF THE WORLDS BIGGEST COMPANIES IN THE SECTOR.
General Cable Corporation is one of the worlds leading cable manufacturing companies. In its work it has
contributed decisively to progress and improvements in peoples quality of life.
Through innovation and technology General Cable is present in the development and evolution of society. Withmore than 13,000 associates operating in 26 countries and 57 manufacturing facilities, General Cable is a global
leader in the supply of products and services to the global oil, gas and petrochemical industry.
The company has a hundred-year tradition and its own values based on customer satisfaction, integrity in all
it does, teamwork, delivery speed, creativity and innovation, and ongoing improvement, in which people are its
main source of value.
This is General Cable, a company with a commitment to the future, to innovation, and to sustainability. It is a
company prepared to meet its commitment to society and the environment.
-
8/10/2019 Offshore Cable
4/96
-
8/10/2019 Offshore Cable
5/96
INDEX
06
19
08
24
Symbols
Technical information
Introduction
Selection guide
General Cable reserves the right to alter or modify specifications and materials in the light of later technical development.
27
72
Cables for offshore installations
Installation guide
OFFSHORE CABLES
-
8/10/2019 Offshore Cable
6/96
SYMBOLS
FLAME RETARDANT SINGLE WIRE - IEC 60332-1-2
FLAME RETARDANT BUNCHED WIRES - IEC 60332-3-22, cat. A
FIRE RESISTANT - IEC 60331
LOW SMOKE EMISSION - IEC 61034-2
HALOGEN FREE - IEC 60754-1
LOW ACIDITY AND CORROSIVITY OF EVOLVED GASES - IEC 60754-2
INCREASED FLEXIBILITY
MECHANICAL RESISTANCE
HEAVY DUTY6
-
8/10/2019 Offshore Cable
7/96
MINERAL OIL RESISTANCE
HYDROCARBON RESISTANCE
ELECTRO-MAGNETIC INTERFERENCE PROTECTION
MUD OIL RESISTANCE
WORK AT VERY LOW TEMPERATURE -40 C
WEATHERING TEST RESISTANT
REDUCED BENDING RADIUS
WATERTIGHT
7
-
8/10/2019 Offshore Cable
8/96
INTRODUCTION
8
OFFSHORE CABLES
TECHNICAL SPECIFITATION
In this catalogue General Cable presents its series of shipboard energy, control and instrumentation cables for
fixed installations on vessels and oil rigs.
The safety of people and equipment is a priority consideration in the design and construction of Exzhellent-606
and Genfire-606 cables. They are made from zero-halogen compounds with a low-acidity and -corrosivity of
gases evolved and a low opacity of fumes evolved during combustion, in accordance with the corresponding IEC
standards. They therefore allow for quick, safe evacuation in the event of fire.
The cables are designed to comply with the strictest non-fire propagation standards and prevent the generation
of secondary seats of fire even in circumstances of high cable concentration in unfavourable conditions.
There are also fire-resistant designs that feature not only the above properties, but are also able to continue
providing service even when directly affected by fire. Their use in safety services enables the services to continue
working even in situations of fire.
Reinforced cables feature standard tinned copper braiding that provides good mechanical protection and may
also be used in specific applications such as shielding.
Exzhellent-606 and Genfire-606 cables may be used in extreme climates, principally because of their resistance
to very low temperatures.
This catalogue also includes specific designs for energy cables used in circuits with variable frequency drives
(VFD).
The cables described in this catalogue have been designed in accordance with the following standards and
specifications.
8
NEK TS 606
Cables for off-shore installation - Halogen-free and/or mud resistant - Technical specification.
IEC 60092-350
Electrical installations in ships.
IEC 60092-352
Choice and installation of electrical cables.
-
8/10/2019 Offshore Cable
9/96
99
IEC 60092-353
Single and multicore non-radial field power cables with extruded solid insulation for rated voltages 1 kV and
3 kV.
IEC 60092-354
Single and three-core power cables with extruded solid insulation for rated voltafes 6 kV up to 30 kV.
IEC 60092-376
Cables for control and instrumentation circuits 150/250 V.
IEC 60092-351
Insulation materials for shipboard and offshore units, power, control, instrumantarion, telecommunication and
data cables.
IEC 60092-359
Sheathing materials for shipboard power and telecommunication cables.
IEC 60228
Conductors of insulated cables.
IEC 60332-3-22 cat. A
Tests on bunched electric cables under fire conditions, fire retardant.
IEC 60331-21Circuit integrity - Procedures and requirements for cables up to and including 0,6/1 kV.
IEC 60331-1
Circuit integrity - Test method for a temperature of at least 830 C for cables rated up to 0,6/1 kV and with an
overall diameter exceeding 20 mm.
IEC 60331-2
Circuit integrity - Test method for a temperature of at least 830 C for cables rated up to 0,6/1 kV and with an
overall diameter not exceeding 20 mm.
IEC 60754-1
Determination of the amount of halogen acid gas .
-
8/10/2019 Offshore Cable
10/96
10
Cables shown in this cataloge are covered with Type Approvals from main classification societies:
ABS BUREAU VERITAS GERMANISCHER LLOYD
DET NORSKE VERITASLLOYDS REGISTER
10
IEC 60754-2
Determination of degree of acidity of gases.
IEC 61034-2
Measurement of smoke density.
-
8/10/2019 Offshore Cable
11/96
1111
APLICATIONS
Depending on their use, the cables are distributed into the following groups:
LOW VOLTAGE POWER CABLES (NEK TS 606)
Power cables suitable for operation at up to and including 0.6/1 kV.
Constructions up to and including 4 core. Coloured core identification.
Non armoured and armoured with tinned copper wire braid.
Available designs with mud resistance and/or fire resistance (circuit integrity).
Available designs for variable frequency drives (VFD).
MEDIUM VOLTAGE CABLES (NEK TS 606)
Cables for distribution of energy in voltages of 3,6/6 to 12/20 kV.
Armoured with tinned copper wire braid.
Available designs with mud resistance.
CONTROL CABLES (NEK TS 606)
Available from 2 to 37 cores. Identification by numbering.
Armoured with tinned copper wire braid.
Available designs with mud resistance and/or fire resistance (circuit integrity).
INTRUMENTATION CABLES (NEK TS 606)
Multiunit (pairs or triple core).
Cores identified by colours and numbered tape in each unit.
Two pair cable without individual screen has a star/quad composition. Individual and/or collective screening of units using Cu / Poliester tape and drain wire.
Cable screening using tinned copper wire braid.
CONSTRUCTION
On the basis of the above-mentioned IEC standards, and reviewing the formation of the cables, we have:
Conductor
Tinned annealed copper in accordance with IEC 60092-350:
Class 2: Rigid conductors with 7 wire formation (in small sections) or concentric layers in big cross sections.
Class 5: Flexible conductors bunched or multibunched configurations.
In general those class 2 are used, but the use of class 5 is growing, due to their handeability and therefore their
greater ease of installation.
-
8/10/2019 Offshore Cable
12/96
1212
Tin plated conductor is used to offer greater protection of conections against oxidation in heavy marine
environments.
See the following tables for standarized sections and compositions to be used:
CROSS SECTIONAL AREA
Cable type IEC Standard(kV)Voltage
(mm2)
Area ofconductor
Power Low Voltage1 kV3 kV
1,5 : 300 mm2
10 : 300 mm2
6 kV10 kV15 kV20 kV
10 : 630 mm2
16 : 630 mm2
25 : 630 mm2
35 : 630 mm2
250 V 0,50 : 2,50 60092-376
60092-354
60092-353
Instrumentation
Power MediumVoltage
COMPOSITION NUMBER OF CORES
Cable type IEC StandardNumber of
cores
Power L.V. N (Not specified)
1,2*4,7,10,14,19,24,30,37 pairs
2,4,7,12,19,27,37cores
60092-376
60092-376
60092-354
60092-353
Control cables
Instrumentation
Power M.V. 1 or 3 cores
(*) Two pair cable is a star-quad composition, cores diametrally oposed are used to conform the pairs.
-
8/10/2019 Offshore Cable
13/96
1313
Insulation materials
NEK TS 606specifies insulation materials making reference to standard IEC 60092-351. The ones used in the
current catalog are:
EPR (Ethylene propylene). A thermosetting elastomer, it has an almost nil distortion due to the action of heat. It
gives the cable greater flexibility. Especially suitable if the sheath has to be a crosslinked compound.
HEPR (Hard grade etylene propylene).Improved EPR compound bringing beter performance both in mechanical
o electrical properties. This brings to a thickness insulations similars to the XLPE ones.
INSULATION MATERIALS
T ype of insulating compound Short-circuitAbbreviateddesignation NormalOperation
Maximum rated conductor Temperature C
Elastomeric or thermoset
EPR
HEPR
90 250
90 250
Ethylene-propylene rubber or similar(EPM o EPDM) Halogen free
High modulus of hard grade halogen freeethylene propylene rubber
Sheating materials
The sheath of the cables protects the set of cores from the mechanical or environmental aggressions they can
suffer. Mechanical aggressions are mainly abrasions from the dragging of the cables and tears at angles of the
tubes and occur during the installation, while the environment aggressions (heat, presence of oils or aggressive
agents) will affect the cable throughout its working life.
Halogen free termosetting compound SHF 2.
It has the advantages of being a heat-stable compound which does not release toxic gases or opaques smoke
in case of fire (see annex 2), and it has good resistance to oils, fuel and solvents. Good resistance to mechanical
demands.
-
8/10/2019 Offshore Cable
14/96
1414
Type of sheathing compound Abbreviated designation
Elastomeric or thermoset
SHF 2
SHF Mud
Ethylene-propylene rubber or similar(EPM o EPDM) Halogen free
High modulus of hard grade halogen freeethylene propylene rubber
ArmouringThe armour gives the cable mechanical protection. The copper in tinplated version being used in this case.
The use of tinned copper in the armour performs a dual function as it behaves as armour but also as a screen.
Type Materials
BRAID Tinned annealed copper
Screening
In low tensin cables, the screens are the elements which provide the cable protection against electromagnetic
fields. This is an element especially suitable for cables for instrumentation, control and transmission of signals
thanks to its sensitivity to radiation which can distort the signal transmitted by the cable. To protect the cablefrom radiation it is necessary to screen the group of conductors (protection from external disturbance) or each
one of the pairs or triples (electromagnetic fields from other elements of the same cable).
According to the standard, screens can be either braid or laminated polyester tape.
In all designs of 2, 3 and 4 cores, the screen cross-section has been defined according to the criteria set in
standard IEC 60092-352 Table 2, so it can be used as an earthing conductor.
In armoured type cables, the use of tinned copper wire braid armour, when properly earthed, allows to use it as
a collective screen.Type Materials
BRAID
TAPE
Tinned annealed copper
Cu / Polyester
Halogen-free mud-resistant crosslinked compound SHF Mud.
The same characteristics as per material type SHF 2 adding mud resistance according to NEK TS 606.
-
8/10/2019 Offshore Cable
15/96
1515
Electromagnetic compatibility (EMC)
When General Cable products are installed in accordance with IEC 60533, they fulfil the requirements for
Electro-Magnetic Compatibility.
To establish how cables perform in the event of fire, a series of standards have been developed to define fire
conditions and measure the cables performance in a similar situation to that of the installation. It should
nonetheless be remembered that these tests establish fixed, reproducible conditions used to appraise the
performance of the cables in this situation. Current IEC standards envisage the following events:
Flame retardant (IEC 60332-1-2)
A 1 kW flame in contact with the cable sheath for a time established in
the standard should not spread. The cable will not therefore prompt a fire
caused by a minor incident or by an external heat source with which it
comes into accidental contact.
Flame retardant (IEC 60332-3-22)
A fire unconnected with the cable may affect a wiring system and
become more serious if the system is oriented vertically, thus
allowing the circulation of air and the creation of a chimney effect. If
the decomposition temperature of the organic materials is reached,
exothermic combustion of the cables occurs and the fire spreads. The
insulation compounds used in Exzhellent-606 y Genfire-606 cable
sheaths are designed to hinder exothermic reaction. To simulate thissituation, the test involves the application of powered air and a 20-kW
gas burner to a bundle of cables arranged to simulate a vertical wiring
system. In these conditions, a fire in the cables prolonged for 40 must
go out in the time established in the standard and must not exceed a
length of 2.5 metres. The prescribed standard applicable in the ship
industry is IEC 60332, part. 3-22, cat A. Category A prescribes the
maximum volume of inflammable material (seven litres per metre).
Fire resistance (IEC 60331)
IEC 60331 defines the test conditions applied to a cable that must remain
in service in safety circuits even when directly affected by a fire and when
its organic parts are decomposing.
IEC 60332-1
FIRE PERFORMANCE OF CABLES
-
8/10/2019 Offshore Cable
16/96
1616
In the test, the cable is subject to the action of a burner at a minimum
flame temperature of 750 C (standard IEC 60331-21) or of 830 C (for
cables with an overall diameter of over 20 mm in IEC 60331-1 and forcables with an overall diameter not exceeding 20 mm in IEC 60331-2) for
a period of 90 minutes, during and at the end of which the cable must
remain in service.
Halogen-free and low smoke emission cables
Cables subject to fire, depending on the materials of which they are
made, may give off gases that are toxic for peoples health or corrosive
and therefore hinder the proper operation and preservation of the
electronic and IT components in the vicinity. Opaque smoke that prevents
a view of the escape routes from the affected sites may also be given off.
To minimise these effects, General Cable has developed the Exzhellent
series cables that eliminate harmful emissions of halogenated and toxic
gases (IEC 60754-1 and 60754-2), substantially reduce opaque smokes
and thus facilitate the evacuation of people (IEC 61034-2).
IEC 60332-3-22 Cat. A
IEC 60332-3IEC 60331
-
8/10/2019 Offshore Cable
17/96
1717
IEC 60754-1 IEC 61034
Sheathing material Standards Units
Index oxigen limit ASTM-D-2863 35 36 36
280 290 290
180 >60 200
4,3
ASTM-D-2863
IEC 60754-1
IEC 60754-2
IEC 61034-2
%
%
%
pH
CTemperature index
Halogen content
Corrosivity index
Smoke density (Dm)
Thermoplastic Thermosetting Crosslinked
Halogen Free Halogen Free Halogen FreeMud Resistant
SHEATHING MATERIALS
ANNEX 1
-
8/10/2019 Offshore Cable
18/96
18
SMOKE EMISSION CHARACTERISTICS
ANNEX 2
0 2
Tiempo (minutos) / Time (minutes)
%T
ransmitancia/%t
ransmittance
4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40
10
20
30
40
50
60
70
80
90
100
ST2 (PVC)
SE1 (CP)
SHF 1
SHF 2
Unaged Tensile Strenght IEC 60092-359 9,0 9,0 9,0
120 120 120
-25C -40C -40C
7 d. @ 100C 7 d. @ 120C 7 d. @ 120C
n.a.IRM 902
24h @ 100C
IRM 902 24h @ 100CIRM 903 7 d. @ 100C
Calcium Bromide Brine56 d. @ 70C
Carbo Sea 56 d. @ 70C
IEC 60092-359
IEC 60092-359
NEK TS 606
IEC 60811
N/mm2
%Unaged Elongation atBreak
Ageing in air over
Oil Resistance / MUD
Minimum Low Temp.Operation
MATERIAL MECHANICAL CHARACTERISTICS
-
8/10/2019 Offshore Cable
19/96
19
TECHNICAL INFORMATION
CABLE DESIGNATION
Cable designation is based in the letter code described in the tables below:
Halogen free design
Materials InsulationInner covering / Inner
SheathAdditional
characteristics
Fire resistant tape +insulation B
O
U
VFD
X
R
F
Ethylene PropyleneRubber (EPR)
Inner covering
No armour
Tinned Copper wirebraid
Thermoset compoundSHF 2 or SHF Mud
Unit screening (i) Individual(c) Collective
Variable frequencydrives
Armour /Shield Outer Sheath
The cable designation also includes the number and size of cores (NxS), substituing the symbol x by the
symbol G when an earth core is required. In two, three or four core cables armoured power, the NxS/E
terminology is used to illustrate the cables in wich the copper wire braid armour can be employed as the earth
conductor. In this case, the cross sectional area of the braid (E) is equal or greater than 50% of the phase conductors.
CURRENT CARRYING CAPACITIES
General Cable recommends the utilisation of current ratings according to standard IEC 61892-4 based on
conductor temperature of 90 C and ambient temperature of 45 C. As an alternative, it is possible to use the
current ratings included in the regulations of third-party bodies.
De-rating factors for differing methods of installation, and ambient temperatures are specified in IEC 61892-4.
-
8/10/2019 Offshore Cable
20/96
20
CABLE OVERALL DIAMETER TOLERANCE
Nominal overalldiameter
(mm) Low voltage power & control
+1,0-0,5 +2,0-1,0< 20
+2,0
+2,5
+3,0
+3,5
+4,0
+5,0
+5,5
-0,5
-0,75
-0,75
-0,75
-1,0
-1,0
-1,0
+2,5
+3,0
+4,0
+4,5
+5,0
+6,0
+6,5
-1,0
-1,5
-1,5
-1,5
-1,5
-1,5
-1,5
20 - 29,9
30 - 39,9
40 - 49,9
50 - 59,9
60 - 69,9
70 - 79,9
> 79,9
High voltage power
Tolerance
(mm)
20
Number of pairs or triples
5 +1,5-1,5
6 - 10
> 104
5 - 8
> 8
+1,5
+2,5+1,5
+2,0
+2,5
-2,0
-2,5-1,5
-1,5
-2,5
Instrumentation
Tolerance(mm)
ParesPairs
TrosTriples
R: minimum bending radius; a lower radius does not guarantee cable integrity as it may have suffered potential
damage that shortens its useful life.
MINIMUM BENDING RADIUS (IEC 60092-352)
R
Cable
-
8/10/2019 Offshore Cable
21/96
21
MINIMUM BENDING RADIUS (IEC 61892-4)Up to and including 1,8/3 kV
Insulation Covering (D)
Nominal overalldiameter Minimum internal
radius of bend
Thermoplastic orthermosetting
Circular copperconductors
Unarmoured or unbraided
Metal braid screenedor armoured Any
< 25 mm 4 D a
6 D> 25 mm
6 D
Composite polyester/metal tapescreened units or collective tape
screeningAny 8 D
a) 6D for circuit integrity
Higher than 1,8/3 kV
Any 12 DSingle core Any
Any 9 D3 core cable Any
CORE IDENTIFICATIONPower cables up to 1,8/3 kV
Number of cores EarthNeutralPhase
2
3
4
4+E
3+E
2+E
-
8/10/2019 Offshore Cable
22/96
Instrumentation cables of 150/250 V
Grey sheathIntrinsically safe circuits: Blue sheathTwo pair cables collectively screened are laid up with diametrically opposite cores.
n equals number of each pair or triple
n nPair
n nnTriple
1
2
2
1Two pairs collective
screen
Multi-conductor control cables of 250 V or 0,6/1 kV
n 1 2 3 4 n
n equals the correlative conductor number
Power cables of 3,6/6 kV and aboveNumber of cores
3
22
-
8/10/2019 Offshore Cable
23/96
23
TECHNICAL DATA FOR OFFSHORE INSTRUMENTATION CABLES
Data @ 1000 Hz
Standard Fire resistant
0,75 0,751,5 1,5 Units
Conductor cross sectional area(mm2)
/km14,127,6 14,127,6Cond. Resistance(DC) 20C
/km14,127,6 14,127,6Cond. Resistance(AC) 20C
mH/km0,6120,635 0,6580,721Inductance
/km14,127,6 14,127,6Impedance
253333 265366Characteristicimpedance
dB/km0,570,75 0,550,68Signal attenuation
nF/km6360 5852Mutual capacitanceaprox.
Electricalproperties
Characteristicproperties
100000100001000100
0.1
2
3
4
5
6
7
8
9
2
3
4
5
6
7
8
910.0
1.0
Attenuation(dB/km)
Frequency (Hz)
-
8/10/2019 Offshore Cable
24/96
24
SELECTION GUIDE
CABLE SELECTION
Rated voltage Type Armoured Mud resistant Serie Page
0,6/1 kV
3,6/6 kV
6/10 kV
8,7/15 kV
12/20 kV
3,6/6 kV
6/10 kV8,7/15 kV
12/20 kV
250 V
P1 RFOU
P1/P8 RFOU
P18 RU
P2 RFOU
P3 RFOU
P4 RFOU
P19 RFOU
P2/P9 RFOU
P3/P10 RFOUP4/P11 RFOU
P19/P21 RFOU
S1 RFOU(i)
S2 RFOU(c)
S11 RU(i)
S12 RU(c)
S1/S5 RFOU(i)
S2/S6 RFOU(c)
x
x
x
x
x
x
x
xx
x
x
x
x
x
x
x
xx
x
x
x
x
7475 2469
7476 2470
7479
7480
7481
7482
7483
7484
74857486
7487
4271 4281
4272 4282
4267
4268
4273 4283
4274 4284
28
30
32
34
34
34
34
36
3636
36
38
40
42
44
46
48
POWERL.V.
POWERM.V.
INSTRUMENTA-TION
-
8/10/2019 Offshore Cable
25/96
CIRCUIT INTEGRITY CABLES (IEC 60331) FIRE RESISTANT
Rated voltage Type Armoured Mud resistant Serie Page
0,6/1 kV
250 V
P5 BFOU
P5/P12 BFOU
P17 BU
S3 BFOU(i)
S4 BFOU(c)
S13 BU (i)
S14 BU (c)
S3/S7 BFOU(i)
S4/S8 BFOU(c)
x
x
x
x
x
x
x
x
x
x
x
7473 2473
7474 2474
7478
4275 4285
4276 4286
4269
4270
4277 4287
4278 4288
50
52
54
56
58
60
62
64
66
POWERL.V.
INSTRUMENTA-TION
25
CABLES FOR VARIABLE FREQUENCY DRIVES (VFD)
Rated voltage Type Armoured Mud resistant Serie Page
0,6/1 kV
3,6/6 kV6/10 kV
8,7/15 kV
12/20 kV
18/30 kV
RFOU-VFD
RFOU-VFD
x
xx
x
x
x
x
xx
x
x
x
7490
79417942
7943
7944
7945
68
70
POWERL.V.
POWERM.V.
-
8/10/2019 Offshore Cable
26/96
-
8/10/2019 Offshore Cable
27/96
CABLES FOR
OFFSHOREINSTALLATIONS
-
8/10/2019 Offshore Cable
28/96
EXZHELLENT 606Type P1 RFOU
MAIN USES AND FEATURES Armoured cables for installation in offshore applications with special
performances on flame spread and low emission of smoke and fumes.
Oil resistant.Max. rated conductor temperature in normal operation: 90C.
Minimum working temperature -40 C.
CONSTRUCTION
Tinned copper, stranded class 2.
1. CONDUCTOR
Halogen free compound.
3. INNER COVERING
Tinned copper wire braid.
4. BRAID ARMOUR
Thermoset compound type SHF 2.
IEC 60092-359.
5. OUTER SHEATH
Ethylene Propylene Rubber.
IEC 60092-351.
Core identification: see pages 21 and 22.
2. INSULATION
1
2
3
4
5
28
Rated voltage: 0,6 / 1 kV
Armoured
POWER
IEC 60092-351
IEC 60092-353
IEC 60092-359
NEK TS 606
IEC 60754-1
IEC 60754-2
IEC 61034-2
IEC 60332-1-2
IEC 60332-3-22
STANDARDS
-
8/10/2019 Offshore Cable
29/96
(mm2) (kg/km) (mH/km)Nominal cross Weight Inductance
(mm) (mm) (V/A. km)
Diameter underarmour
Overalldiameter
Voltage drop(COS=0.8)
7475206
7475207
7475208
7475306
7475307
7475308
7475309
7475310
7475311
7475312
7475313
7475314
7475315
7475316
7475317
7475318
7475406
7475407
24690562469057
2469076
2469077
2469126
2469127
2469196
2469197
2x1,5
2x2,5
2x4
3x1,5/1,5
3x2,5/2,5
3x4/4
3x6/6
3x10/10
3x16/16
3x25/16
3x35/17,5
3x50/25
3x70/35
3x95/47,5
3x120/60
3x150/75
4x1,5/1,5
4x2,5/2,5
5x1,55x2,5
7x1,5
7x2,5
12x1,5
12x2,5
19x1,5
19x2,5
9,0
10,0
11,0
9,5
10,5
11,5
13,5
15,5
17,5
20,5
23,0
26,5
30,0
34,5
41,0
45,5
10,5
11,5
11,513,0
12,5
14,0
17,0
18,5
20,0
22,0
12,5
13,5
15,0
13,0
14,5
15,5
17,5
19,5
22,0
25,5
28,0
32,0
36,5
41,0
47,5
52,5
14,5
15,5
16,017,0
17,0
18,0
21,5
23,0
24,5
27,0
240
290
385
275
365
440
560
745
1015
1405
1790
2435
3290
4470
5975
7320
350
430
420515
485
595
730
915
990
1260
21,7
13,5
8,41
21,7
13,5
8,41
5,60
3,35
2,14
1,39
1,02
0,779
0,560
0,427
0,353
0,302
21,7
13,5
21,713,5
21,7
13,5
21,7
13,7
21,7
13,5
0,376
0,350
0,328
0,376
0,350
0,328
0,317
0,296
0,281
0,278
0,268
0,264
0,250
0,248
0,231
0,231
0,376
0,350
0,3760,350
0,376
0,350
0,376
0,350
0,376
0,350
Code
29
-
8/10/2019 Offshore Cable
30/96
EXZHELLENT 606
MAIN USES AND FEATURES
CONSTRUCTION
1
2
3
4
5
Type P1/P8 RFOU
30
Armoured cables for installation in offshore applications with special
performances on flame spread and low emission of smoke and fumes.
Halogen free, oil and mud resistant.Max. rated conductor temperature in normal operation: 90 C.
Minimum working temperature -20 C.
Tinned copper, stranded class 2.
1. CONDUCTOR
Halogen free compound.
3. INNER COVERING
Tinned copper wire braid.
4. BRAID ARMOUR
Thermoset compound mud resistant type SHF Mud.
NEK TS 606.
5. OUTER SHEATH
Ethylene Propylene Rubber.
IEC 60092-351.
Core identification: see pages 21 and 22.
2. INSULATION
Rated voltage: 0,6 / 1 kV
MUD RESISTANT
Armoured
POWER
IEC 60092-351
IEC 60092-353
IEC 60092-359
NEK TS 606
IEC 60754-1
IEC 60754-2
IEC 61034-2
IEC 60332-1-2
IEC 60332-3-22
STANDARDS
-
8/10/2019 Offshore Cable
31/96
(mm2) (kg/km) (mH/km)Nominal cross Weight Inductance
(mm) (mm) (V/A. km)
Diameter underarmour
Overalldiameter
Voltage drop(COS=0.8)
Code
0,384
0,357
0,335
0,384
0,357
0,335
0,324
0,302
0,287
0,284
0,274
0,269
0,255
0,253
0,247
0,244
0,384
0,357
0,3760,350
0,376
0,350
0,376
0,350
0,376
0,350
25,0
15,6
9,71
21,7
13,5
8,41
5,60
3,35
2,14
1,39
1,02
0,779
0,560
0,427
0,353
0,302
21,7
13,5
21,713,5
21,7
13,5
21,7
13,5
21,7
13,5
245
295
385
280
370
445
565
750
1020
1410
1790
2430
3305
4480
5975
7345
350
425
420515
485
595
730
915
990
1260
12,5
13,5
15,0
13,0
14,5
15,5
17,5
19,5
22,0
25,5
28,0
32,0
36,0
41,5
47,5
52,5
14,5
15,5
16,017,0
17,0
18,0
21,5
23,0
24,5
27,0
9,0
10,0
11,0
9,5
10,5
11,5
13,5
15,5
17,5
20,5
23,0
26,5
30,0
35,0
41,0
45,5
10,5
11,5
11,513,0
12,5
14,0
17,0
18,5
20,0
22,0
2x1,5
2x2,5
2x4
3x1,5/1,5
3x2,5/2,5
3x4/4
3x6/6
3x10/10
3x16/16
3x25/16
3x35/17,5
3x50/25
3x70/35
3x95/47,5
3x120/60
3x150/75
4x1,5/1,5
4x2,5/2,5
5x1,55x2,5
7x1,5
7x2,5
12x1,5
12x2,5
19x1,5
19x2,5
7476206
7476207
7476208
7476306
7476307
7476308
7476309
7476310
7476311
7476312
7476313
7476314
7476315
7476316
7476317
7476318
7476406
7476407
24700562470057
2470076
2470077
2470126
2470127
2470196
2470197
31
-
8/10/2019 Offshore Cable
32/96
EXZHELLENT 606
1
2
3
Type P18 RU
32
MAIN USES AND FEATURES
CONSTRUCTION
Unarmoured cables for installation in offshore applications with special
performances on flame spread and low emission of smoke and fumes.
Oil resistant.Max. rated conductor temperature in normal operation: 90 C.
Minimum working temperature -40 C.
Tinned copper, stranded class 2.
1. CONDUCTOR
Ethylene Propylene Rubber.
IEC 60092-351.
Core identification: see pages 21 and 22.
2. INSULATION
Rated voltage: 0,6 / 1 kV
Non armoured
POWER
Thermoset compound mud resistant type SHF 2.
IEC 60092-359
3. OUTER SHEATH
IEC 60092-351
IEC 60092-353
IEC 60092-359
NEK TS 606
IEC 60754-1
IEC 60754-2
IEC 61034-2
IEC 60332-1-2
IEC 60332-3-22
STANDARDS
-
8/10/2019 Offshore Cable
33/96
(mm2) (kg/km) (mH/km)Nominal cross Weight Inductance
(mm) (mm) (V/A. km)
Diameter underarmour
Overalldiameter
Voltage drop(COS=0.8)
7479206
7479207
7479208
7479306
7479307
7479308
7479309
7479310
7479311
7479312
7479313
7479314
7479315
7479316
7479317
7479318
7479406
7479407
74794087479409
7479410
7479411
7479412
7479413
7479414
2x1,5
2x2,5
2x4
3x1,5/1,5
3x2,5/2,5
3x4/4
3x6/6
3x10/10
3x16/16
3x25/16
3x35/17,5
3x50/25
3x70/35
3x95/47,5
3x120/60
3x150/75
4x1,5/1,5
4x2,5/2,5
4x4/44x6/6
4x10/10
4x16/16
4x25/16
4x35/17,5
4x50/25
10,4
11,2
12,3
11,1
12,1
13,1
14,4
16,4
18,6
22
24,5
30,5
34,3
39,2
43
47,2
12,3
13,3
14,616,1
18,3
20,7
24,5
27,3
34,3
170
205
260
195
250
315
395
565
785
1165
1525
2240
3015
4055
4980
5995
240
295
390495
710
990
1480
1940
2875
45
45
50
45
50
55
60
70
75
90
100
185
210
235
260
285
50
55
6065
75
85
100
165
210
21,7
13,5
8,42
21,7
13,5
8,42
5,61
3,35
2,15
1,39
1,03
0,781
0,563
0,429
0,355
0,304
21,69
13,48
8,425,61
3,35
2,15
1,39
1,03
0,781
0,419
0,389
0,364
0,419
0,389
0,364
0,34
0,316
0,299
0,294
0,283
0,277
0,263
0,26
0,253
0,25
0,419
0,389
0,3640,34
0,316
0,299
0,294
0,283
0,277
Code
33
-
8/10/2019 Offshore Cable
34/96
EXZHELLENT 606
Semiconducting material and tinned copper wire braid.
Core identification: see pages 21 and 22.
4. INSULATION SCREENING
Halogen free compound.
Tinned copper wire braid.
Thermoset compound type SHF 2.
IEC 60092-359.
5. INNER COVERING
6. BRAID ARMOUR
7. OUTER SHEATH
Type RFOU
1
2
3
4
7
5
6
34
MAIN USES AND FEATURES
CONSTRUCTION
Medium voltage power cables for installation in offshore applications with
special performances on flame spread and low emission of smoke and
fumes.Oil resistant.
Max. rated conductor temperature in normal operation: 90 C.
Minimum working temperature -40 C.
Tinned copper, stranded class 2.
1. CONDUCTOR
Semiconducting material.
2. CONDUCTOR SCREENING
Ethylene Propylene Rubber (EPR).
IEC 60092-351.
3. INSULATION
Rated voltage: 3,6 / 6 kV - 6 / 10 kV
- 8,7 / 15 kV - 12 / 20 kV
Armoured
POWER
IEC 60092-351
IEC 60092-354
IEC 60092-359
NEK TS 606
IEC 60754-1
IEC 60754-2
IEC 61034-2
IEC 60332-1-2
IEC 60332-3-22
STANDARDS
-
8/10/2019 Offshore Cable
35/96
Code (mm2) (kg/km)Nominal cross Weight
(mm) (mm)
Diameter underarmour
Overalldiameter
ohm/km
Inductivereactance
(F/km)Capacitance
0,283
0,322
0,359
0,3990,432
0,526
0,288
0,327
0,359
0,399
0,132
0,125
0,118
0,1140,110
0,102
0,115
0,109
0,102
0,098
45
45
50
4550
55
60
70
75
90
25,0
26,5
28,0
30,031,5
36,5
48,5
52,0
55,0
60,0
20,0
21,5
23,5
25,026,5
31,0
41,5
45,0
48,0
52,0
1x50
1x70
1x95
1x1201x150
1x240
3x50/25
3x70/35
3x95/47,5
3x120/60
7480114
7480115
7480116
74801177480118
7480120
7480314
7480315
7480316
7480317
Type P3 RFOU
0,257
0,288
0,324
0,359
0,3890,472
0,257
0,288
0,324
0,359
0,135
0,126
0,121
0,115
0,1110,104
0,117
0,109
0,104
0,100
1265
1525
1855
2165
24853565
4395
5300
6805
7750
26,0
27,5
29,5
31,0
32,537,0
49,5
53,0
61,0
62,0
21,0
27,5
24,0
26,0
27,531,5
42,5
46,0
53,0
54,0
1x50
1x70
1x95
1x120
1x1501x240
3x50/25
3x70/35
3x95/47,5
3x120/60
7481114
7481115
7481116
7481117
74811187481120
7481314
7481315
7481316
7481317
Rated voltage: 6/10 kV
Type P4 RFOU
0,208
0,233
0,260
0,287
0,309
0,373
0,212
0,233
0,260
0,287
0,140
0,132
0,126
0,121
0,117
0,109
0,124
0,116
0,110
0,105
1430
1695
2035
2380
2730
3870
5490
6345
7700
8865
28,0
30,0
31,5
34,0
35,5
40,0
59,5
62,5
67,0
70,0
23,0
24,5
26,5
28,5
30,0
34,0
52,0
54,0
58,5
61,5
1x50
1x70
1x95
1x120
1x150
1x240
3x50/25
3x70/35
3x95/47,5
3x120/60
7482114
7482115
7482116
7482117
7482118
7482120
7482314
7482315
7482316
7482317
Rated voltage: 8,7/15 kV
Type P19 RFOU
0,181
0,201
0,223
0,246
0,264
0,3160,181
0,201
0,223
0,246
0,145
0,136
0,131
0,125
0,121
0,1130,130
0,120
0,116
0,111
1580
1865
2240
2560
2995
42405820
6775
8140
9405
30,5
32,0
34,5
36,0
38,5
43,560,5
64,0
68,5
72,5
25,5
26,5
29,0
30,5
32,0
36,552,5
56,0
60,0
63,5
1x50
1x70
1x95
1x120
1x150
1x2403x50/25
3x70/35
3x95/47,5
3x120/60
7483114
7483115
7483116
7483117
7483118
74831207483314
7483315
7483316
7483317
Rated voltage: 12/20 kV
35
Type P2 RFOU Rated voltage: 3,6/6 kV
-
8/10/2019 Offshore Cable
36/96
EXZHELLENT 606Type RFOU
1
2
3
4
7
5
6
36
Semiconducting material and tinned copper wire braid.
Core identification: see pages 21 and 22.
4. INSULATION SCREENING
Halogen free compound.
Tinned copper wire braid.
Thermoset compound mud resistant type SHF Mud.
NEK TS 606.
5. INNER COVERING
6. BRAID ARMOUR
7. OUTER SHEATH
MAIN USES AND FEATURES
CONSTRUCTION
Medium voltage power armoured cables for installation in offshore
applications with special performances on flame spread and low emission
of smoke and fumes.Halogen free, oil and mud resistant.
Max. rated conductor temperature in normal operation: 90 C.
Minimum working temperature -20 C.
Tinned copper, stranded class 2.
1. CONDUCTOR
Semiconducting material.
2. CONDUCTOR SCREENING
Ethylene Propylene Rubber (EPR).
IEC 60092-351.
3. INSULATION
Rated voltage: 3,6 / 6 kV - 6 / 10 kV
- 8,7 / 15 kV - 12 / 20 kV
MUD RESISTANT
Armoured
POWER
IEC 60092-351
IEC 60092-354
IEC 60092-359
NEK TS 606
IEC 60754-1
IEC 60754-2
IEC 61034-2
IEC 60332-1-2
IEC 60332-3-22
STANDARDS
-
8/10/2019 Offshore Cable
37/96
Type P2/P9 RFOU
Code (mm2) (kg/km)Nominal cross Weight
(mm) (mm)
Diameter underarmour
Overalldiameter
ohm/km
Inductivereactance
(F/km)Capacitance
0,283
0,322
0,359
0,3990,432
0,526
0,288
0,327
0,359
0,399
0,132
0,125
0,118
0,1140,110
0,102
0,115
0,109
0,102
0,098
1210
1475
1775
20902405
3495
4240
5170
6260
7495
25,0
26,5
28,0
30,031,5
36,5
48,5
52,0
55,0
60,0
20,0
21,5
23,5
25,026,5
31,0
41,5
45,0
48,0
52,0
1x50
1x70
1x95
1x1201x150
1x240
3x50/25
3x70/35
3x95/47,5
3x120/60
7484114
7484115
7484116
74841177484118
7484120
7484314
7484315
7484316
7484317
Rated voltage: 3,6/6 kV
Type P3/P10 RFOU
0,257
0,288
0,324
0,359
0,3890,472
0,257
0,288
0,324
0,359
0,135
0,126
0,121
0,115
0,1110,104
0,117
0,109
0,104
0,100
1265
1525
1855
2165
24853565
4395
5300
6805
7750
26,0
27,5
29,5
31,0
32,537,0
49,5
53,0
61,0
62,0
21,0
27,5
24,0
26,0
27,531,5
42,5
46,0
53,0
54,0
1x50
1x70
1x95
1x120
1x1501x240
3x50/25
3x70/35
3x95/47,5
3x120/60
7485114
7485115
7485116
7485117
74851187485120
7485314
7485315
7485316
7485317
Rated voltage: 6/10 kV
Type P4/P11 RFOU
0,208
0,233
0,260
0,287
0,309
0,373
0,212
0,233
0,260
0,287
0,140
0,132
0,126
0,121
0,117
0,109
0,124
0,116
0,110
0,105
1430
1695
2035
2380
2730
3870
5490
6345
7700
8865
28,0
30,0
31,5
34,0
35,5
40,0
59,5
62,5
67,0
70,0
23,0
24,5
26,5
28,5
30,0
34,0
52,0
54,0
58,5
61,5
1x50
1x70
1x95
1x120
1x150
1x240
3x50/25
3x70/35
3x95/47,5
3x120/60
7486114
7486115
7486116
7486117
7486118
7486120
7486314
7486315
7486316
7486317
Rated voltage: 8,7/15 kV
Type P19/P21 RFOU
0,181
0,201
0,223
0,246
0,264
0,3160,181
0,201
0,223
0,246
0,145
0,136
0,131
0,125
0,121
0,1130,130
0,120
0,116
0,111
1580
1865
2240
2560
2995
42405820
6775
8140
9405
30,5
32,0
34,5
36,0
38,5
43,560,5
64,0
68,5
72,5
25,5
26,5
29,0
30,5
32,0
36,552,5
56,0
60,0
63,5
1x50
1x70
1x95
1x120
1x150
1x2403x50/25
3x70/35
3x95/47,5
3x120/60
7487114
7487115
7487116
7487117
7487118
74871207487314
7487315
7487316
7487317
Rated voltage: 12/20 kV
37
-
8/10/2019 Offshore Cable
38/96
EXZHELLENT 606
Halogen free compound.
4. INNER COVERING
Tinned copper wire braid.
5. BRAID ARMOUR
Thermoset compound type SHF 2.
IEC 60092-359.
6. OUTER SHEATH
Ethylene Propylene Rubber (EPR).
IEC 60092-351.
Core identification: see pages 21 and 22.
2. INSULATION
1
2
3
4
5
6INSTRUMENTATION
Type S1 RFOU (i)
38
MAIN USES AND FEATURES
CONSTRUCTION
Armoured, individually screened pairs/triples cables for installation in
offshore with special performances on flame spread and low emission of
smoke and fumes.Oil resistant.
Minimum working temperature -40 C.
Tinned copper, stranded class 2.
1. CONDUCTOR
Copper polyester tape with drain wire.
3. INDIVIDUAL SCREEN
Rated voltage: 150 / 250 V
Armoured & individually screened
IEC 60092-351
IEC 60092-359
IEC 60092-376
NEK TS 606
IEC 60754-1
IEC 60754-2
IEC 61034-2
IEC 60332-1-2
IEC 60332-3-22
STANDARDS
-
8/10/2019 Offshore Cable
39/96
(mm2) (kg/km)Nominal cross Weight
(mm) (mm)
Diameter underarmour
Overalldiameter
4271015
4271016
4271025
4271026
4271045
4271046
4271085
4271086
4271125
4271126
4271165
4271166
4271245
4271246
4281015
4281016
4281025
4281026
42810454281046
4281085
4281086
4281125
4281126
4281165
4281166
1x2x1
1x2x1,5
2x2x1
2x2x1,5
4x2x1
4x2x1,5
8x2x1
8x2x1,5
12x2x1
12x2x1,5
16x2x1
16x2x1,5
24x2x1
24x2x1,5
1x3x1
1x3x1,5
2x3x1
2x3x1,5
4x3x14x3x1,5
8x3x1
8x3x1,5
12x3x1
12x3x1,5
16x3x1
16x3x1,5
8,5
8,5
13,5
14,0
16,0
16,5
21,0
22,0
26,0
27,0
29,5
30,5
37,0
38,5
8,5
9,0
15,0
15,5
18,018,5
24,0
24,5
29,5
30,5
33,0
34,5
11,5
12,0
18,0
18,0
20,0
21,0
26,0
27,0
31,0
32,5
35,0
36,5
43,5
45,5
12,0
12,5
19,5
20,0
22,023,0
29,0
29,5
35,0
36,5
39,0
41,0
225
245
515
540
605
680
975
1095
1335
1550
1725
1930
2525
2915
250
265
610
675
755855
1220
1385
1740
1995
2270
2580
Code
Electrical parameters and characteristic properties, see page 23.
39
-
8/10/2019 Offshore Cable
40/96
EXZHELLENT 606
1
2
3
4
5
6
Type S2 RFOU (c)
40
Halogen free compound.
4. INNER COVERING
Tinned copper wire braid.
5. BRAID ARMOUR
Thermoset compound type SHF 2.
IEC 60092-359.
6. OUTER SHEATH
Ethylene Propylene Rubber (EPR).
IEC 60092-351.
Core identification: see pages 21 and 22.
2. INSULATION
INSTRUMENTATION
MAIN USES AND FEATURES
CONSTRUCTION
Armoured, colletively screened pairs/triples cables for installation in
offshore applications with special performances on flame spread and low
emission of smoke and fumes.Oil resistant.
Minimum working temperature -40 C.
Tinned copper, stranded class 2.
1. CONDUCTOR
Copper polyester tape with drain wire.
3. INDIVIDUAL SCREEN
Rated voltage: 150 / 250 V
Armoured & collectively screened
IEC 60092-351
IEC 60092-359
IEC 60092-376
NEK TS 606
IEC 60754-1
IEC 60754-2
IEC 61034-2
IEC 60332-1-2
IEC 60332-3-22
STANDARDS
-
8/10/2019 Offshore Cable
41/96
(mm2) (kg/km)Nominal cross Weight
(mm) (mm)
Diameter underarmour
Overalldiameter
4272025
4272026
4272045
4272046
4272085
4272086
4272125
4272126
4272165
4272166
4272245
4272246
4282025
4282026
4282045
4282046
4282085
4282086
42821254282126
4282165
4282166
2x2x1
2x2x1,5
4x2x1
4x2x1,5
8x2x1
8x2x1,5
12x2x1
12x2x1,5
16x2x1
16x2x1,5
24x2x1
24x2x1,5
2x3x1
2x3x1,5
4x3x1
4x3x1,5
8x3x1
8x3x1,5
12x3x112x3x1,5
16x3x1
16x3x1,5
9,5
10,0
13,5
14,0
16,5
19,5
20,5
21,5
22,0
26,0
28,5
34,0
10,5
13,5
12,5
14,5
15,5
20,5
19,020,0
20,0
24,0
13,0
13,5
17,5
18,0
21,5
24,5
25,5
26,5
27,0
31,0
34,5
40,5
14,5
17,5
16,5
19,0
20,0
25,5
24,525,0
25,5
29,0
285
305
475
525
720
880
975
1140
1195
1465
1710
2230
360
470
530
640
855
1105
12001395
1460
1780
Code
Two pair cables collectively screened are laid up with diametrically opposite cores.
Electrical parametres and characteritic properties, see page 23.
41
-
8/10/2019 Offshore Cable
42/96
IEC 60092-351
IEC 60092-353
IEC 60092-359
NEK TS 606
IEC 60754-1
IEC 60754-2
IEC 61034-2
IEC 60332-1-2
IEC 60332-3-22
STANDARDS INSTRUMENTATION
Thermoset compound type SHF 2.
IEC 60092-359.
4. BRAID ARMOUR
1
2
3
4
EXZHELLENT 606Type S11 RU (i)
42
Ethylene Propylene Rubber (EPR).
IEC 60092-351.
Core identification: see pages 21 and 22.
2. INSULATION
MAIN USES AND FEATURES
CONSTRUCTION
Unarmoured, individually screened pairs/triples cables for installation in
offshore applications with special performances on flame spread and low
emission of smoke and fumes.Oil resistant.
Minimum working temperature -40 C.
Tinned copper, stranded class 2.
1. CONDUCTOR
Copper polyester tape with drain wire.
3. INDIVIDUAL SCREEN
Rated voltage: 150 / 250 V
MUD RESISTANT
Armoured
-
8/10/2019 Offshore Cable
43/96
(mm2) (kg/km)Nominal cross Weight
(mm)
Overalldiameter
4267014
4267016
4267017
4267024
4267026
4267027
4267034
4267036
4267037
4267074
4267076
4267077
4267124
4267126
4267127
4267194
4267196
4267197
42672444267246
4267247
4267274
4267276
4267277
1x2x0,75
1x2x1,5
1x2x2,5
2x2x0,75
2x2x1,5
2x2x2,5
3x2x0,75
3x2x1,5
3x2x2,5
7x2x0,75
7x2x1,5
7x2x2,5
12x2x0,75
12x2x1,5
12x2x2,5
19x2x0,75
19x2x1,5
19x2x2,5
24x2x0,7524x2x1,5
24x2x2,5
27x2x0,75
27x2x1,5
27x2x2,5
7,0
8,0
9,0
11,5
13,5
15,0
12,0
14,5
16,0
16,5
19,5
22,0
22,0
26,5
29,5
26,0
31,5
35,5
31,037,5
42,0
31,5
38,5
43,0
90
125
160
185
230
295
200
295
390
410
610
815
705
1030
1380
1075
1570
2105
13152020
2720
1440
2220
2995
Code
Electrical parameters and characteristic properties, see page 23.
43
-
8/10/2019 Offshore Cable
44/96
Thermoset compound type SHF 2.
IEC 60092-359.
4. OUTER SHEATH
1
2
3
4
EXZHELLENT 606Type S12 RU (c)
44
IEC 60092-351
IEC 60092-359
IEC 60092-376
NEK TS 606
IEC 60754-1
IEC 60754-2
IEC 61034-2
IEC 60332-1-2
IEC 60332-3-22
STANDARDS INSTRUMENTATION
Ethylene Propylene Rubber (EPR).
IEC 60092-351.
Core identification: see pages 21 and 22.
2. INSULATION
MAIN USES AND FEATURES
CONSTRUCTION
Unarmoured, colletively screened pairs/triples cables for installation in
offshore applications with special performances on flame spread and low
emission of smoke and fumes.Oil resistant.
Minimum working temperature -40 C.
Tinned copper, stranded class 2.
1. CONDUCTOR
Copper polyester tape with drain wire.
3. COLLECTIVE SCREEN
Rated voltage: 150 / 250 V
Collectively screened
-
8/10/2019 Offshore Cable
45/96
(mm2) (kg/km)Nominal cross Weight
(mm)
Overalldiameter
4268024
4268026
4268027
4268034
4268036
4268037
4268074
4268076
4268077
4268124
4268126
4268127
4268194
4268196
4268197
4268244
4268246
4268247
42682744268276
4268277
2x2x0,75
2x2x1,5
2x2x2,5
2x2x0,75
3x2x1,5
3x2x2,5
7x2x0,75
7x2x1,75
12x2x0,75
12x2x1,5
12x2x2,5
12x2x2,25
19x2x0,75
19x2x1,5
19x2x2,5
24x2x0,75
24x2x1,5
24x2x2,5
27x2x0,7527x2x1,5
27x2x2,5
11,5
14,0
15,5
12,5
15,0
17,0
16,5
20,0
22,5
22,0
27,0
30,5
26,5
32,0
36,5
31,0
38,0
43,0
32,039,0
44,0
155
220
285
185
280
370
345
540
720
575
895
1225
835
1320
1820
1070
1705
2365
11801860
2590
Code
Two pair cables collectively screened are laid up with diametrically opposite cores.
Electrical parametres and characteritic properties, see page 23.
45
-
8/10/2019 Offshore Cable
46/96
EXZHELLENT 606
1
2
3
4
5
6
Type S1/S5 RFOU (i)
46
Halogen free compound.
4. INNER COVERING
Tinned copper wire braid.
5. BRAID ARMOUR
Thermoset compound mud resistant type SHF Mud.
NEK TS 606.
6. OUTER SHEATH
Ethylene Propylene Rubber (EPR).
IEC 60092-351.
Core identification: see pages 21 and 22.
2. INSULATION
INSTRUMENTATION
MAIN USES AND FEATURES
CONSTRUCTION
Armoured, individually screened pairs/triples cables for installation in
offshore applications with special performances on flame spread and low
emission of smoke and fumes.Halogen free, oil and mud resistant.
Minimum working temperature -20 C.
Tinned copper, stranded class 2.
1. CONDUCTOR
Copper polyester tape with drain wire.
3. INDIVIDUAL SCREEN
Rated voltage: 150 / 250 V
MUD RESISTANT
Armoured & individual screened
IEC 60092-351
IEC 60092-359
IEC 60092-376
NEK TS 606
IEC 60754-1
IEC 60754-2
IEC 61034-2
IEC 60332-1-2
IEC 60332-3-22
STANDARDS
-
8/10/2019 Offshore Cable
47/96
(mm2) (kg/km)Nominal cross Weight
(mm) (mm)
Diameter underarmour
Overalldiameter
4273015
4273016
4273025
4273026
4273045
4273046
4273085
4273086
4273125
4273126
4273165
4273166
4273245
4273246
4283015
4283016
4283025
4283026
42830454283046
4283085
4283086
4283125
4283126
4283165
4283166
1x2x1
1x2x1,5
2x2x1
2x2x1,5
4x2x1
4x2x1,5
8x2x1
8x2x1,5
12x2x1
12x2x1,5
16x2x1
16x2x1,5
24x2x1
24x2x1
1x3x1
1x3x1,5
2x3x1
2x3x1,5
4x3x14x3x1,5
8x3x1
8x3x1,5
12x3x1
12x3x1,5
16x3x1
16x3x1,5
8,5
8,5
13,5
14,0
16,0
16,5
21,0
22,0
26,0
27,5
29,5
30,5
36,5
38,0
8,5
9,0
15,0
15,5
18,018,5
24,0
24,5
29,5
30,5
33,0
34,5
11,5
12,0
18,0
18,0
20,0
21,0
26,0
27,0
31,0
32,5
35,0
36,0
43,5
45,0
12,0
12,5
19,5
20,0
22,023,0
29,0
29,5
35,0
36,5
39,0
41,0
230
250
525
560
620
690
995
1095
1365
1560
1735
1935
2585
2865
255
280
630
690
7701255
1255
1390
1785
2010
2285
2585
Code
Electrical parameters and characteristic properties, see page 23.
47
-
8/10/2019 Offshore Cable
48/96
EXZHELLENT 606
1
2
3
4
5
6
Type S2/S6 RFOU (c)
48
Halogen free compound.
4. INNER COVERING
Tinned copper wire braid.
5. BRAID ARMOUR
Thermoset compound mud resistant type SHF Mud.
NEK TS 606.
6. OUTER SHEATH
Ethylene Propylene Rubber (EPR).
IEC 60092-351.
Core identification: see pages 21 and 22.
2. INSULATION
INSTRUMENTATION
MAIN USES AND FEATURES
CONSTRUCTION
Armoured, colectively screened pairs/triples cables for installation in
offshore applications with special performances on flame spread and low
emission of smoke and fumes.Halogen free, oil and mud resistant.
Minimum working temperature -20 C.
Tinned copper, stranded class 2.
1. CONDUCTOR
Copper polyester tape with drain wire.
3. COLLECTIVE SCREEN
Rated voltage: 150 / 250 V
MUD RESISTANT
Armoured & collectively screened
IEC 60092-351
IEC 60092-359
IEC 60092-376
NEK TS 606
IEC 60754-1
IEC 60754-2
IEC 61034-2
IEC 60332-1-2
IEC 60332-3-22
STANDARDS
-
8/10/2019 Offshore Cable
49/96
(mm2) (kg/km)Nominal cross Weight
(mm) (mm)
Diameter underarmour
Overalldiameter
4274025
4274026
4274045
4274046
4274085
4274086
4274125
4274126
4274165
4274166
4274245
4284246
4284025
4284026
4284045
4284046
4284085
4284086
42841254284126
4284165
4284166
2x2x1
2x2x1,5
4x2x1
4x2x1,5
8x2x1
8x2x1,5
12x2x1
12x2x1,5
16x2x1
16x2x1,5
24x2x1
24x2x1,5
2x3x1
2x3x1,5
4x3x1
4x3x1,5
8x3x1
8x3x1,5
12x3x112x3x1,5
16x3x1
16x3x1,5
9,5
10,0
13,5
14,0
16,5
17,5
20,5
21,5
22,0
22,5
28,5
29,5
10,5
12,0
12,5
14,5
15,5
18,0
19,020,0
20,0
24,0
13,0
13,5
17,5
18,0
21,0
22,0
25,5
26,5
27,0
28,0
34,5
36,0
14,5
16,0
16,5
19,0
20,0
23,0
24,525,0
25,5
29,5
285
315
480
535
725
825
1005
1145
1205
1385
1765
2135
365
435
535
645
865
1045
12101405
1465
1825
Code
Two pair cables collectively screened are laid up with diametrically opposite cores.
Electrical parametres and characteritic properties, see page 23.
49
-
8/10/2019 Offshore Cable
50/96
1
2
3
4
6
5
Type P5 BFOUGENFIRE 606
50
Halogen free compound.
4. INNER COVERING
Tinned copper wire braid.
5. BRAID ARMOUR
Thermoset compound type SHF 2.
IEC 60092-359.
6. OUTER SHEATH
2. MICA TAPE
POWER
MAIN USES AND FEATURES
CONSTRUCTION
Armoured cables for installation in offshore applications with special
performances on flame spread and low emission of smoke and fumes.
Fire and oil resistant.Minimum working temperature
-40 C.
Tinned copper, stranded class 2.
1. CONDUCTOR
Ethylene Propylene Rubber (EPR).
IEC 60092-351.
Core identification: see pages 21 and 22.
3. INSULATION
Rated voltage: 0,6 / 1 kV
FIRE RESISTANT
Armoured
IEC 60092-351
IEC 60092-353
IEC 60092-359
NEK TS 606
IEC 60754-1
IEC 60754-2
IEC 61034-2
IEC 60331-21
IEC 60331-1 and -2
IEC 60332-1-2
IEC 60332-3-22
STANDARDS
-
8/10/2019 Offshore Cable
51/96
(mm2) (kg/km) (mH/km)Nominal cross Weight Inductance
(mm) (mm) (V/A. km)
Diameter underarmour
Overalldiameter
Voltage drop(COS=0.8)
7473206
7473207
7473208
7473306
7473307
7473308
7473309
7473310
7473311
7473312
7473313
7473314
7473315
7473316
7473317
7473318
7473406
7473407
24730562473057
2473076
2473077
2473126
2473127
2473196
2x1,5
2x2,5
2x4
3x1,5/1,5
3x2,5/2,5
3x4/4
3x6/6
3x10/10
3x16/16
3x25/16
3x35/17,5
3x50/25
3x70/35
3x95/47,5
3x120/60
3x150/75
4x1,5/1,5
4x2,5/2,5
5x1,55x2,5
7x1,5
7x2,5
12x1,5
12x2,5
19x1,5
10,0
10,5
11,5
10,5
11,5
12,5
13,5
15,5
17,5
21
23
27
30,5
35
41,5
46
11,5
12,5
1314
14
15
18,5
20,5
22
13,5
15
16
14,5
15,5
16,5
18
20
22
26
28,5
32
36
41,5
48,5
53
15,5
16,5
1718,5
18,5
19,5
23,5
25
27
275
355
415
345
400
475
580
770
1030
1450
1820
2430
3310
4485
6020
7365
390
460
470555
540
650
820
995
1110
21,7
13,5
8,42
21,7
13,5
8,42
5,6
3,35
2,15
1,39
1,03
0,78
0,56
0,43
0,35
0,3
-
-
--
-
-
-
-
-
0,41
0,38
0,35
0,41
0,38
0,35
0,33
0,31
0,29
0,29
0,28
0,27
0,26
0,26
0,25
0,25
-
-
--
-
-
-
-
-
Code
51
-
8/10/2019 Offshore Cable
52/96
1
2
3
4
6
5
Type P5/P12 BFOUGENFIRE 606
52
Halogen free compound.
4. INNER COVERING
Tinned copper wire braid.
5. BRAID ARMOUR
Thermoset compound mud resistant type SHF Mud.
NEK TS 606.
6. OUTER SHEATH
2. MICA TAPE
POWER
MAIN USES AND FEATURES
CONSTRUCTION
Armoured cables for installation in offshore applications with special
performances on flame spread and low emission of smoke and fumes.
Halogen free, fire, oil and mud resistant.Max. rated conductor temperature in normal operation: 90 C.
Minimum working temperature -20 C.
Tinned copper, stranded class 2.
1. CONDUCTOR
Ethylene Propylene Rubber (EPR).
IEC 60092-351.
Core identification: see pages 21 and 22.
3. INSULATION
Rated voltage: 0,6 / 1 kV
FIRE & MUD RESISTANT
Armoured
IEC 60092-351
IEC 60092-353
IEC 60092-359
NEK TS 606
IEC 60754-1
IEC 60754-2
IEC 61034-2
IEC 60331-21
IEC 60331-1 and -2
IEC 60332-1-2
IEC 60332-3-22
STANDARDS
-
8/10/2019 Offshore Cable
53/96
(mm2) (kg/km) (mH/km)Nominal cross Weight Inductance
(mm) (mm) (V/A. km)
Diameter underarmour
Overalldiameter
Voltage drop(COS=0.8)
7474206
7474207
7474208
7474306
7474307
7474308
7474309
7474310
7474311
7474312
7474313
7474314
7474315
7474316
7474317
7474318
7474406
7474407
24740562474057
2474076
2474077
2474126
2474127
2474196
2x1,5
2x2,5
2x4
3x1,5/1,5
3x2,5/2,5
3x4/4
3x6/6
3x10/10
3x16/16
3x25/16
3x35/17,5
3x50/25
3x70/35
3x95/47,5
3x120/60
3x150/75
4x1,5/1,5
4x2,5/2,5
5x1,55x2,5
7x1,5
7x2,5
12x1,5
12x2,5
19x1,5
10,0
10,5
11,5
10,5
11,5
12,5
13,5
15,5
17,5
21
23
27
30,5
35
41,5
46
11,5
12,5
1314
14
15
18,5
20,5
22
13,5
15
16
14,5
15,5
16,5
18
20
22
26
28,5
32
36
41,5
48,5
53
15,5
16,5
1718,5
18,5
19,5
23,5
25
27
275
355
415
345
400
475
580
770
1030
1450
1820
2430
3310
4485
6020
7365
390
460
470555
540
650
820
995
1110
21,6
13,4
8,42
21,6
13,4
8,42
5,6
3,35
2,15
1,39
1,03
0,78
0,56
0,43
0,35
0,3
-
-
--
-
-
-
-
-
0,41
0,38
0,35
0,41
0,38
0,35
0,33
0,31
0,29
0,29
0,28
0,27
0,26
0,26
0,25
0,25
-
-
--
-
-
-
-
-
Code
53
-
8/10/2019 Offshore Cable
54/96
IEC 60331-21
IEC 60331-1 and -2
IEC 60332-1-2
IEC 60332-3-22
Ethylene Propylene Rubber (EPR).
IEC 60092-351.
Core identification: see pages 21 and 22.
3. INSULATION
Thermoset compound mud resistant type SHF Mud.
NEK TS 606.
4. OUTER SHEATH
2. MICA TAPE
1
2
3
4
Type P17 BUGENFIRE 606
54
IEC 60092-351
IEC 60092-353
IEC 60092-359
NEK TS 606
IEC 60754-1
IEC 60754-2
IEC 61034-2
STANDARDS INSTRUMENTATION
MAIN USES AND FEATURES
CONSTRUCTION
Unarmoured cables for installation in offshore applications with special
performances on flame spread and low emission of smoke and fumes.
Halogen free, fire, oil and mud resistant.Max. rated conductor temperature in normal operation: 90 C.
Minimum working temperature -20 C.
Tinned copper, stranded class 2.
1. CONDUCTOR
Rated voltage: 0,6 / 1 kV
FIRE RESISTANT
Non amoured
-
8/10/2019 Offshore Cable
55/96
(mm2) (kg/km) (mH/km)Nominal cross Weight Inductance
(mm) (V/A. km)
Overalldiameter
Voltage drop(COS=0.8)
7478206
7478207
7478208
7478306
7478307
7478308
7478309
7478310
7478311
7478312
7478313
7478314
7478315
7478316
7478317
7478318
7478406
7478407
74784087478409
7478410
7478411
7478412
7478413
7478414
2x1,5
2x2,5
2x4
3x1,5/1,5
3x2,5/2,5
3x4/4
3x6/6
3x10/10
3x16/16
3x25/16
3x35/17,5
3x50/25
3x70/35
3x95/47,5
3x120/60
3x150/75
4x1,5/1,5
4x2,5/2,5
4x4/44x6/6
4x10/10
4x16/16
4x25/16
4x35/17
4x50/25
9,5
10
11
10
10,5
12
13,5
16
18
21,5
24
30
34
39
43
47,5
10,5
12
1315,5
17,5
20
24
27
33,5
125
160
205
150
190
260
345
505
715
1080
1430
2105
2865
3845
4745
5820
180
235
315435
625
890
1360
1810
2670
21,7
13,5
8,41
21,7
13,5
8,41
5,57
3,32
2,12
1,37
1,01
0,76
0,54
0,41
0,34
0,29
21,68
13,47
8,415,57
3,32
2,12
1,37
1,01
0,76
0,38
0,36
0,34
0,38
0,36
0,34
0,22
0,22
0,22
0,22
0,21
0,21
0,2
0,2
0,2
0,2
0,38
0,36
0,340,22
0,22
0,22
0,22
0,21
0,21
Code
55
-
8/10/2019 Offshore Cable
56/96
Thermoset comp
NEK TS 606.
7. OUTER SHEATH
1
2
3
4
5
6
7
Type S3 BFOU (i)
56
Copper polyester tape with drain wire.
4. INDIVIDUAL SCREEN
Halogen free compound.
5. INNER COVERING
Tinned copper wire braid.6. BRAID ARMOUR
2. MICA TAPE
INSTRUMENTATION
MAIN USES AND FEATURES
CONSTRUCTION
Armoured, individualy screened pairs/triples cables for installation in
offshore applications with special performances of non fire propagation
and low emission of smoke and fumes.Fire and oil resistant.
Minimum working temperature -40 C.
Tinned copper, stranded class 2.
1. CONDUCTOR
Ethylene Propylene Rubber (EPR).
IEC 60092-351.
Core identification: see pages 21 and 22.
3. INSULATION
Rated voltage: 150 / 250 V
FIRE RESISTANT
Armoured & individual screened
IEC 60092-351
IEC 60092-359
IEC 60092-376
NEK TS 606
IEC 60754-1
IEC 60754-2
IEC 61034-2
IEC 60331-21
IEC 60331-1 and -2
IEC 60332-1-2
IEC 60332-3-22
STANDARDS
GENFIRE 606
-
8/10/2019 Offshore Cable
57/96
(mm2) (kg/km)Nominal cross Weight
(mm) (mm)
Diameter underarmour
Overalldiameter
4275015
4275016
4275025
4275026
4275045
4275046
4275085
4275086
4275125
4275126
4275165
4275166
4275245
4275246
4285015
4285016
4285025
4285026
42850454285046
4285085
4285086
4285125
4285126
4285165
4285166
1x2x1
1x2x1,5
2x2x1
2x2x1,5
4x2x1
4x2x1,5
8x2x1
8x2x1,5
12x2x1
12x2x1,5
16x2x1
16x2x1,5
24x2x1
24x2x1,5
1x3x1
1x3x1,5
2x3x1
2x3x1,5
4x3x14x3x1,5
8x3x1
8x3x1,5
12x3x1
12x3x1,5
16x3x1
16x3x1,5
9,0
9,5
14,5
15,0
17,5
18,0
23,0
24,0
29,5
29,5
32,5
33,5
41,0
42,0
9,5
10,0
16,5
17,0
19,520,0
26,0
27,5
32,5
33,5
36,5
38,0
12,5
12,5
19,0
19,5
22,0
22,5
28,0
29,0
35,0
35,5
38,5
39,5
48,0
49,5
13,0
13,0
21,0
21,5
24,025,0
31,0
32,5
38,5
39,5
43,0
45,0
250
260
560
595
680
735
1065
1190
1565
1685
1960
2180
2845
3175
270
290
695
760
850940
1360
1560
2060
2270
2535
2895
Code
Electrical parameters and characteristic properties, see page 23.
57
-
8/10/2019 Offshore Cable
58/96
GENFIRE 606
1
2
3
4
5
7
6
Type S4 BFOU (c)
58
Thermoset compound type SHF 2.
IEC 60092-359.
7. OUTER SHEATH
Copper polyester tape with drain wire.
4. COLLECTIVE SCREEN
Halogen free compound.
5. INNER COVERING
Tinned copper wire braid.6. BRAID ARMOUR
2. MICA TAPE
INSTRUMENTATION
MAIN USES AND FEATURES
CONSTRUCTION
Armoured, collectively screened pairs/triples cables for installation in
offshore applications with special performances on flame spread and low
emission of smoke and fumes.Fire and oil resistant.
Minimum working temperature -40 C.
Tinned copper, stranded class 2.
1. CONDUCTOR
Ethylene Propylene Rubber (EPR).
IEC 60092-351.
Core identification: see pages 21 and 22.
3. INSULATION
Rated voltage: 150 / 250 V
FIRE RESISTANT
Armoured & collectively screened
IEC 60092-351
IEC 60092-359
IEC 60092-376
NEK TS 606
IEC 60754-1
IEC 60754-2
IEC 61034-2
IEC 60331-21
IEC 60331-1 and -2
IEC 60332-1-2
IEC 60332-3-22
STANDARDS
-
8/10/2019 Offshore Cable
59/96
(mm2) (kg/km)Nominal cross Weight
(mm) (mm)
Diameter underarmour
Overalldiameter
4276025
4276026
4276045
4276046
4276085
4276086
4276125
4276126
4276165
4276166
4276245
4276246
4286025
4286026
4286045
4286046
4286085
4286086
42861254286126
4286165
4286166
2x2x1
2x2x1,5
4x2x1
4x2x1,5
8x2x1
8x2x1,5
12x2x1
12x2x1,5
16x2x1
16x2x1,5
24x2x1
24x2x1,5
2x3x1
2x3x1,5
4x3x1
4x3x1,5
8x3x1
8x3x1,5
12x3x112x3x1,5
16x3x1
16x3x1,5
10,5
11,0
14,5
15,0
18,5
21,5
22,5
24,0
24,0
25,5
31,5
33,0
11,0
14,5
13,5
15,5
17,0
22,5
21,022,0
22,5
26,5
14,0
14,5
18,5
19,5
23,0
26,5
28,0
29,0
29,5
31,0
37,5
40,0
15,0
19,0
18,0
20,0
22,0
27,5
26,527,5
28,0
32,0
305
340
515
580
790
960
1090
1270
1305
1530
1925
2350
395
565
590
700
935
1190
13101545
1620
1965
Code
Two pair cables collectively screened are laid up with diametrically opposite cores.
Electrical parametres and characteritic properties, see page 23.
59
-
8/10/2019 Offshore Cable
60/96
1
2
3
4
5
GENFIRE 606Type S13 BU (i)
60
Thermoset compound type SHF 2.
IEC 60092-359.
5. OUTER SHEATH
Copper polyester tape with drain wire.
4. INDIVIDUAL SCREEN
2. MICA TAPE
INSTRUMENTATION
MAIN USES AND FEATURES
CONSTRUCTION
Unarmoured, individualy screened pairs/triples cables for installation in
offshore applications with special performances of non fire propagation
and low emission of smoke and fumes.Fire and oil resistant.
Minimum working temperature -40 C.
Tinned copper, stranded class 2.
1. CONDUCTOR
Ethylene Propylene Rubber (EPR).
IEC 60092-351.
Core identification: see pages 21 and 22.
3. INSULATION
Rated voltage: 150 / 250 V
FIRE RESISTANT
Individually screened
IEC 60092-351
IEC 60092-359
IEC 60092-376
NEK TS 606
IEC 60754-1
IEC 60754-2
IEC 61034-2
IEC 60331-21
IEC 60331-1 and -2
IEC 60332-1-2
IEC 60332-3-22
STANDARDS
-
8/10/2019 Offshore Cable
61/96
(mm2) (kg/km)Nominal cross Weight
(mm)
Overalldiameter
4269014
4269016
4269017
4269024
4269026
4269027
4269034
4269036
4269037
4269074
4269076
4269077
4269124
4269126
4269127
4269194
4269196
4269197
42692444269246
4269247
4269274
4269276
4269277
1x2x0,75
1x2x1,5
1x2x2,5
2x2x0,75
2x2x1,5
2x2x2,5
3x2x0,75
3x2x1,5
3x2x2,5
7x2x0,75
7x2x1,5
7x2x2,5
12x2x0,75
12x2x1,5
12x2x2,5
19x2x0,75
19x2x1,5
19x2x2,5
24x2x0,7524x2x1,5
24x2x2,5
27x2x0,75
27x2x1,5
27x2x2,5
8,0
9,0
10,0
13,0
15,0
16,5
13,5
16,0
17,5
18,0
21,5
24,0
24,5
29,0
32,5
29,5
35,0
39,0
35,041,5
46,0
35,5
42,5
47,5
100
140
175
185
260
325
235
335
435
460
680
900
785
1150
1540
1170
1745
2340
15102265
3005
1655
2485
3330
Code
Two pair cables collectively screened are laid up with diametrically opposite cores.
Electrical parametres and characteritic properties, see page 23.
61
-
8/10/2019 Offshore Cable
62/96
1
2
3
4
5
GENFIRE 606Type S14 BU (c)
62
Thermoset compound type SHF 2.
IEC 60092-359.
5. OUTER SHEATH
Copper polyester tape with drain wire.
4. COLLECTIVE SCREEN
2. MICA TAPE
INSTRUMENTATION
MAIN USES AND FEATURES
CONSTRUCTION
Unarmoured, collectively screened pairs/triples cables for installation in
offshore applications with special performances on flame spread and low
emission of smoke and fumes.Fire and oil resistant.
Minimum working temperature -40 C.
Tinned copper, stranded class 2.
1. CONDUCTOR
Ethylene Propylene Rubber (EPR).
IEC 60092-351.
Core identification: see pages 21 and 22.
3. INSULATION
Rated voltage: 150 / 250 V
FIRE RESISTANT
Collectively screened
IEC 60092-351
IEC 60092-359
IEC 60092-376
NEK TS 606
IEC 60754-1
IEC 60754-2
IEC 61034-2
IEC 60331-21
IEC 60331-1 and -2
IEC 60332-1-2
IEC 60332-3-22
STANDARDS
-
8/10/2019 Offshore Cable
63/96
(mm2) (kg/km)Nominal cross Weight
(mm)
Overalldiameter
4270024
4270026
4270027
4270034
4270036
4270037
4270074
4270076
4270077
4270124
4270126
4270127
4270194
4270196
4270197
4270144
4270146
4270147
42702744270276
4270277
2x2x0,75
2x2x1,5
2x2x2,5
3x2x0,75
3x2x1,5
3x2x2,5
7x2x0,75
7x2x1,5
7x2x2,5
12x2x0,75
12x2x1,5
12x2x2,5
19x2x0,75
19x2x1,5
19x2x2,5
24x2x0,75
24x2x1,5
24x2x2,5
27x2x0,7527x2x1,5
27x2x2,5
13,0
15,5
17,0
14,0
16,5
18,0
18,5
22,0
24,5
25,0
30,0
33,5
30,0
35,5
40,0
35,5
42,5
47,0
36,043,5
48,5
200
285
370
220
320
405
405
600
805
675
1020
1360
985
1500
2040
1275
1960
2625
13852135
2895
Code
Two pair cables collectively screened are laid up with diametrically opposite cores.
Electrical parametres and characteritic properties, see page 23.
63
-
8/10/2019 Offshore Cable
64/96
GENFIRE 606
1
2
3
4
5
6
7
Type S3/S7 BFOU (i)
64
Thermoset compound mud resistant type SHF Mud.
NEK TS 606.
7. OUTER SHEATH
Copper polyester tape with drain wire.
4. INDIVIDUAL SCREEN
Halogen free compound.
5. INNER COVERING
Tinned copper wire braid.6. BRAID ARMOUR
2. MICA TAPE
INSTRUMENTATION
MAIN USES AND FEATURES
CONSTRUCTION
Armoured. individually screened pairs/triples cables for installation in
offshore applications with special performances on flame spread and low
emission of smoke and fumes.Halogen free, fire, oil and mud resistant.
Minimum working temperature -20 C.
Tinned copper, stranded class 2.
1. CONDUCTOR
Ethylene Propylene Rubber (EPR).
IEC 60092-351.
Core identification: see pages 21 and 22.
3. INSULATION
Rated voltage: 150 / 250 V
FIRE & MUD RESISTANT
Armoured & individual screened
IEC 60092-351
IEC 60092-359
IEC 60092-376
NEK TS 606
IEC 60754-1
IEC 60754-2
IEC 61034-2
IEC 60331-21
IEC 60331-1 and -2
IEC 60332-1-2
IEC 60332-3-22
STANDARDS
-
8/10/2019 Offshore Cable
65/96
(mm2) (kg/km)Nominal cross Weight
(mm) (mm)
Diameter underarmour
Overalldiameter
4277015
4277016
4277025
4277026
4277045
4277046
4277085
4277086
4277125
4277126
4277165
4277166
4277245
4277246
4287015
4287016
4287025
4287026
42870454287046
4287085
4287086
4287125
4287126
4287165
4287166
1x2x1
1x2x1,5
2x2x1
2x2x1,5
4x2x1
4x2x1,5
8x2x1
8x2x1,5
12x2x1
12x2x1,5
16x2x1
16x2x1,5
24x2x1
24x2x1,5
1x3x1
1x3x1,5
2x3x1
2x3x1,5
4x3x14x3x1,5
8x3x1
8x3x1,5
12x3x1
12x3x1,5
16x3x1
16x3x1,5
9,0
9,5
14,5
15,0
17,5
18,0
23,0
24,0
28,5
29,5
32,5
33,5
41,0
42,0
9,5
10,0
16,5
17,0
19,520,0
26,0
27,0
32,5
33,5
36,5
38,0
12,0
12,5
19,0
19,5
22,0
22,5
28,0
29,0
34,0
35,5
38,5
39,5
48,0
49,0
12,5
13,0
21,0
21,5
24,025,0
31,0
32,0
38,5
39,5
43,0
45,0
245
265
580
620
685
740
1075
1190
1530
1695
1975
2185
2865
3165
270
290
720
770
865940
1370
1525
2060
2305
2555
2900
Code
Electrical parameters and characteristic properties, see page 23.
65
-
8/10/2019 Offshore Cable
66/96
GENFIRE 606
1
2
3
4
5
6
7
Type S4/S8 BFOU (c)
66
Thermoset compound mud resistant type SHF Mud.
NEK TS 606.
7. OUTER SHEATH
Copper polyester tape with drain wire.
4. COLLECTIVE SCREEN
Halogen free compound.
5. INNER COVERING
Tinned copper wire braid.6. BRAID ARMOUR
2. MICA TAPE
INSTRUMENTATION
MAIN USES AND FEATURES
CONSTRUCTION
Armoured, collectively screened pairs/triples cables for installation in
offshore applications with special performances on flame spread and low
emission of smoke and fumes.Halogen free, fire, oil and mud resistant.
Minimum working temperature -20 C.
Tinned copper, stranded class 2.
1. CONDUCTOR
Ethylene Propylene Rubber (EPR).
IEC 60092-351.
Core identification: see pages 21 and 22.
3. INSULATION
Rated voltage: 150 / 250 V
FIRE & MUD RESISTANT
Armoured & individual screened
IEC 60092-351
IEC 60092-359
IEC 60092-376
NEK TS 606
IEC 60754-1
IEC 60754-2
IEC 61034-2
IEC 60331-21
IEC 60331-1 and -2
IEC 60332-1-2
IEC 60332-3-22
STANDARDS
-
8/10/2019 Offshore Cable
67/96
(mm2) (kg/km)Nominal cross Weight
(mm) (mm)
Diameter underarmour
Overalldiameter
4278025
4278026
4278045
4278046
4278085
4278086
4278125
4278126
4278165
4278166
4278245
4278246
4288025
4288026
4288045
4288046
4288085
4288086
42881254288126
4288165
4288166
2x2x1
2x2x1,5
4x2x1
4x2x1,5
8x2x1
8x2x1,5
12x2x1
12x2x1,5
16x2x1
16x2x1,5
24x2x1
24x2x1,5
2x3x1
2x3x1,5
4x3x1
4x3x1,5
8x3x1
8x3x1,5
12x3x112x3x1,5
16x3x1
16x3x1,5
10,5
11,0
14,5
17,0
18,5
21,5
22,5
24,0
24,0
29,0
31,5
37,5
11,0
14,5
13,5
18,0
17,0
22,5
21,022,0
22,5
30,5
14,0
14,5
18,5
21,5
23,0
26,5
28,0
29,0
29,5
34,0
37,5
44,0
15,0
19,0
18,0
22,5
22,0
27,5
26,527,5
28,0
36,0
310
340
525
615
800
970
1100
1280
1315
1625
1940
2450
395
560
595
765
940
1195
13201555
1630
2090
Code
Two pair cables collectively screened are laid up with diametrically opposite cores.
Electrical parametres and characteritic properties, see page 23.
67
-
8/10/2019 Offshore Cable
68/96
1
2
3
4
5
Ethylene propylene rubber (EPR).
IEC 60092-351.
Core identification: see pages 21 and 22.
EXZHELLENT 606Type RFOU-VFD
68
Copper/polyester tape.
Tinned copper wire braid.
(95 % coverage density)
4. SCREEN / ARMOUR
Thermoset compound type SHF Mud.
NEK TS 606.
5. OUTER SHEATH
2. INSULATION
INSTRUMENTATION
MAIN USES AND FEATURES
CONSTRUCTION
Armoured cables for variable frequency drive systems with maximum
degree of screening for both low and high frequencies. Combined shield
coverage: 100%.Flexible conductor to improve handeability in installation process.
Fire retardant. Halogen free. Oil and Mud Resistant.
Max. rated conductor temperature in normal operation: 90 C.
Minimum working temperature -20 C.
Tinned copper, stranded class 2 (Flexible).
1. CONDUCTOR
Halogen free compound.
3. INNER COVERING
Rated voltage: 0,6 / 1 kV
VARIABLE FREQUENCY DRIVE
MUD RESISTANT / Armoured
IEC 60092-351
IEC 60092-353
IEC 60092-359
NEK TS 606
IEC 60754-1
IEC 60754-2
IEC 61034-2
IEC 60332-1-2