OFF GRID SOLAR INVERTER€¦ · OFF GRID SOLAR INVERTER KEY FEATURES High frequency pure sine wave...
Transcript of OFF GRID SOLAR INVERTER€¦ · OFF GRID SOLAR INVERTER KEY FEATURES High frequency pure sine wave...
OFF GRID SOLAR INVERTER
KEY FEATURES
● High frequency pure sinewave design
● Multi-functional inverter-charger with programmablemenus
● Inverter + 60A AC Charger +50A Solar Charger
● Total system charging : 50A +60A = 110A !!
● Adjustable Bulk/Float Voltand charging current
● Wide AC input range
● Lightweight, easy to install
● 2X surge capacity max 5s
● FREE monitoring software
● LCD Display + LED indicators
● Support main battery typese.g. Lead Acid, LiFePO4*
● Built-in genset starter drycontact**
● USB communication interface
PIP-HS series 812 1624 2424 3248 4048 1212 (1224)
ELECTRICAL SPECIFICATIONS
Continuous Output 800W 1600W 2400W 3200W 4000W 1200W
Surge Rating 5 seconds max, 2X
Input Power Factor 0.8
Input Voltage Range 90~280VAC (Appliance mode), 170~280VAC (UPS mode)
Input Max Voltage 300VAC
Input/Output Frequency 50Hz / 60Hz
Output Voltage 230VAC±5%
Output Waveform Pure Sine Wave
Output Regulation < 3% RMS for battery voltage range
Output Short Circuit Circuit Breaker
Peak Efficiency >95% (line mode) / 91% (inverter mode)
Nominal DC Voltage 12V 24V 48V 12V (24V)
Transfer Time <10ms (UPS mode), <20ms (Appliance mode) **
Charging Mode 3-stage
MAX DC Input 15V 15V 30V 60V
Bulk Volt (Flooded, AGM) 14.6, 14.1V 29.2, 28.2V 58.4, 56.4V 14.6, 14.1V (29.2, 28.2V)
Float Volt 13.5V 27.0V 54.0V 13.5V (27V)
AC Recharging Current 10/20amp 20/30amp 60 amp 60 amp
No Load Consumption <15W <25W <50W <25W
Power Saving Consumption <5W <10W <15W <10W
SOLAR CHARGER
Type, Max Charging Current PWM, max 50 Amp
System DC Voltage 12V 24V 48V 12V (24V)
Max PV Input Voc 30V 60V 90V 40V (75V)
Standby Power 1W 2W 1W (2W)
ENVIRONMENTAL / MECHANICAL SPECIFICATIONS
Certification CE
Operating/Storage Temp. 0°C ~ 55°C / -15°C~ 60°C
Operating Humidity 20~90%RH Non-Condensing
Dimension 316*240*95mm 355*272*100mm 468*295*120mm 355*272*100mm
Net Weight 5.0Kg 6.5Kg 7.0Kg 10Kg 10Kg 6.8Kg
Only 48V models are PARALLEL–READY. Optional Parallel Kit isrequired for all units in parallel
and sold separately.
AC CHARGER
PURE SINE WAVE
HIGH FREQUENCY
LCD DISPLAY
MONITORING
STACKABLE*
PB ACID /LIFEPO4
* Only on 48v models
Note: Product specifications are subject to change without prior notice. MPP Solar is a registered trademark of MPP Solar Inc.
*For LiFePo4 suitability, please check with your battery supplier on charging and BMS requirement.
** Inverter-Generators are recommended for better compatibility
**Product specifications are subject to change without prior notice. MPP Solar is a registered trademark of MPP Solar Inc.
Optional Accessories
This accessory is applicable only to
select 48VDC models of HS and MS series
inverters. It is a required component to
be installed in every unit of a parallel
system. A parallel kit includes:
● 1 X PARALLEL BOARD
● 1 X PARALLEL COMM CABLE
● 1 X CURRENT SHARING CABLE
This device is an extension of the HS/MS inverter’s
LCD module and allows user to implement control
on settings and monitoring from a distance away.
This remote module can coexist with the built-in
LCD device and is compatible with most
12v/24v/48v models in the HS/MS inverter series*.
Maximum operating distance: 15m via RJ45
network cable
*This accessory is not fully compatible with 1212HS and 1212MS. Some parameters may not show
**For more details on pricing, availability and installation guide, please contact us directly.
*IMPORTANT: please do not wire 12v or 24v HS/MS inverters in parallel, as this will result instant
damage of all units!
MPP Solar Inc. reserves the right to change product specification without notice. MPP Solar is a registered trademark.
● NEW! energy-efficient power factor 1.0 design
● Special designed for price sensitive consumers
● Lighter in weight, 1-5KW available
● Equalization charging available
● Increased DC limit up to 33V/63V
● Increased bulk/float voltage up to 31.5V/61V
● Fuse protection against reverse battery
● High frequency pure sine wave design
● PMW & MPPT models available
● Suitable for Off-Grid or with Grid
● Programmable parameters
● Max up to 60A utility charging
● Adjustable charging voltage
● Wide AC input range
● Lightweight, easy to install
● 2X surge capacity max 5s
● FREE monitoring software
● LCD Display + LED indicators
● USB communication interface
MAIN FEATURES
HIGH DC VOLT 33V/63V EQUALIZATION CHARGING
COMPACT DESIGN FUSE PROTECTION (DC
REVERSE POLARITY)
Max 31.5V @ 24V
Max 61.0V @ 48V
PIP-HSE/MSE 1012HSE 2024HSE 3024HSE 3024MSE 3024MSXE 5048HSE 5048MSE
ELECTRICAL SPECIFICATION
Continuous Output 1000W 2000W 3000W 3000W 3000W 5000W 5000W
Surge Rating 2X
Input Power Factor 1
Input Voltage Range 90~280VAC (Appliance mode), 170~280VAC (UPS mode)
Input/Output Frequency 50Hz / 60Hz
Output Voltage 230VAC±5%
Output Waveform Pure Sine Wave
Output Short Circuit Circuit Breaker
Peak Efficiency 93%
Nominal DC Voltage 12V 24V 48V
Max DC Input 16V 31V 33V 63V
Transfer Time <10ms (UPS mode), <20ms (Appliance mode)
Charging Mode 3-stage
Max AC Charging Current 20A 20A 25A 60A 60A
Max Equalization Charge 15V 30V 31.5V 61V
No Load consumption <25W <55W
SOLAR CHARGER SPECIFIATIONS
Charging Algorithm PWM PWM PWM MPPT MPPT PWM MPPT
Max Charging Current 50A 50A 50A 40A 60A 50A 60A
Max PV Input Voc 55V 80V 80V 105V 145V 105V 145V
MPPT Range N/A N/A N/A 30 ~ 80V 30 ~ 115V N/A 60 ~ 115V
ENVIRONMENTAL / MECHANICAL SPECIFICATIONS
Certification CE
Operating/Storage Temp. 0°C ~ 55°C / -15°C~ 60°C
Operating Humidity 20~90%RH Non-Condensing
Dimension 320*225*88mm 334*285*100mm 400*300*100mm
Net Weight 5.0Kg 5.8Kg 6.5Kg 9.5Kg 9.0Kg 10Kg
MPP Solar Inc. reserves the right to change product specification without notice. MPP Solar is a registered trademark.
● NEW! 1.6KW—4KW available
● Special revised for OEM volume markets
● Lighter in weight, more integrated design
● Equalization charging available
● Increased DC limit up to 33V/63V
● Increased bulk/float voltage up to 31.5V/61V
● Fuse implementation against battery reversepolarity
● High frequency pure sine wave design
● PMW & MPPT models available
● Suitable for Off-Grid or with Grid
● Programmable parameters
● Max up to 60A utility charging
● Adjustable charging voltage
● Wide AC input range
● Lightweight, easy to install
● 2X surge capacity max 5s
● FREE monitoring software
● LCD Display + LED indicators
● USB communication interface
MAIN FEATURES
HIGH DC VOLT 33V/63V EQUALIZATION CHARGING
COMPACT DESIGN FUSE PROTECTION (DC
REVERSE POLARITY)
Max 31.5V @ 24V
Max 61.0V @ 48V
PIP-HSE/MSE 1624HSE 2424HSE 2424MSE 2424MSXE 4048HSE 4048MSE
ELECTRICAL SPECIFICATION
Continuous Output 1600W 2400W 2400W 2400W 4000W 4000W
Surge Rating 2X
Input Power Factor 0.8
Input Voltage Range 90~280VAC (Appliance mode), 170~280VAC (UPS mode)
Input/Output Frequency 50Hz / 60Hz
Output Voltage 230VAC±5%
Output Waveform Pure Sine Wave
Output Short Circuit Circuit Breaker
Peak Efficiency 93%
Nominal DC Voltage 24V 48V
Max DC Input 32V 63V
Transfer Time <10ms (UPS mode), <20ms (Appliance mode)
Charging Mode 3-stage
Max AC Charging Current 20A 25A 60A 60A
Equalization Charge Yes (max 31.5V@24V, 61V@48v)
No Load consumption <25W <55W
SOLAR CHARGER SPECIFIATIONS
Charging Algorithm PWM PWM MPPT MPPT PWM MPPT
Max Charging Current 50A 50A 40A 60A 50A 60A
Max PV Input Voc 75V 75V 100V 145V 105V 145V
MPPT Range -- -- 30 ~ 80V 30 ~ 115V -- 60 ~ 115V
ENVIRONMENTAL / MECHANICAL SPECIFICATIONS
Certification CE
Operating/Storage Temp. 0°C ~ 55°C / -15°C~ 60°C
Operating Humidity 20~90%RH Non-Condensing
Dimension 320*225*88mm 330*285*90mm 400*300*100mm
Net Weight 5.8Kg 6.5Kg 11Kg 11Kg 13Kg