OF - mwmo.orgdate drw ckd app revision.. hoyer heights reconstruction.\ f in a lp la n \1 2 0 6 7 _...

12
DATE PRI NTED 1 / 16 / 2020 5 : 59 : 43 PM F I LE NAME DATE LIC. NO. DATE: DATE: DATE: DRW: CHK: APP: OF NO. DATE DRW APP CKD REVISION HOYER HEIGHTS RECONSTRUCTION ... \ F i n a l Pl a n \ 12067_ l n01 . dgn LP 600D4569 LP 600D2317 SCJ 47256 SEAN C. JERGENS OF THE STATE OF MINNESOTA. PROFESSIONAL LANDSCAPE ARCHITECT UNDER THE LAWS SUPERVISION AND THAT I AM A DULY LICENSED REPORT WAS PREPARED BY ME OR UNDER MY DIRECT I HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION, OR 12/18/19 1/14/2020 SCJ RB 1/14/2020 1/14/2020 MH 10 11 12 13 MH MH MH MH MH 14 15 16 17 90 100 101 XX 12 LEGEND QUANTITY PLANT SPECIES TO REMAIN EXISTING TREE SEE STORM SEWER PLANS TREE TRENCH CURB CUT, TYP. DECIDUOUS TREE SEE SHEETS - PERENNIAL PLANTINGS 112 114 CONSTR. PLANS SOD - SEE LANDSCAPE GENERAL NOTES: 8. 7. 6. 5. 4. 3. 2. 1. REFER TO PROJECT SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. PLANTING. FIELD. LANDSCAPE ARCHITECT SHALL APPROVE LOCATIONS BEFORE PLAN AND ADJUST IF NECESSARY TO AVOID UTILITY CONFLICTS IN THE CONTRACTOR TO STAKE ALL TREES AND PERENNIAL PLANTING BEDS PER ARCHITECT FOR DIRECTION PRIOR TO PROCEEDING. REPORT ALL LAYOUT DISCREPANCIES IMMEDIATELY TO THE LANDSCAPE COMMENCING. UNDERGROUND UTILITIES ACCORDING TO STATE LAW PRIOR TO ANY WORK CONTRACTOR SHALL COORDINATE LOCATION AND MARKING OF ALL SEE PLANT SCHEDULE ON SHEET . AND LANDSCAPE INSTALLATION. RESTORE ALL TURF AREAS THAT ARE DISTURBED DURING CONSTRUCTION ETC. THAT ARE TO REMAIN. PROTECT ALL EXISTING STRUCTURES, UTILITIES, TREES, SITE AMENITIES, AND START OF CONSTRUCTION. THE CONTRACTOR SHALL VERIFY EXISTING CONDITIONS PRIOR TO BIDDING 117 106 134 ALIGN 36 1/2 AVE NE ALIGN 36 1/2 AVE NE ALIGN TAYLOR ST NE ALIGN FILLMORE ST NE 37 T H AVE NE P OL K S TN E S EEB EL O W M A T C HL I N E- S T A13 + 10 . 0 SEE ABOVE M AT CH L I NE - ST A 13 + 10 . 0 0 HORIZONTAL SCALE IN FEET 20 40 SCALE 40 0 HORIZONTAL SCALE IN FEET 20 40 SCALE 40 LANDSCAPING PLANS BEGIN PROJECT TO 36 1/2 AVE NE STA 16+50 LEGEND NUMBER ITEM DESCRIPTION UNIT TOTAL ESTIMATED 112 112 SEE STORM SEWER PLANS CURB CUT, TYP. S EES H EET M A T C HL I N E- S T A8 9 + 6 0 . 0 108 108 S EES H EET M A T C HL I N E- S T A92 + 0 . 0 107 SEE SHEET M AT CH L I NE ST A 16 + 50 . 0 108 S EES H EET M A T C HL I N E- S T A100 + 45 . 0 PLAN A ON SHEET SEE TREE TRENCH ENLARGEMENT PLAN C ON SHEET SEE TREE TRENCH ENLARGEMENT (NO LANDSCAPE QUANTITIES THIS SHEET)

Transcript of OF - mwmo.orgdate drw ckd app revision.. hoyer heights reconstruction.\ f in a lp la n \1 2 0 6 7 _...

Page 1: OF - mwmo.orgdate drw ckd app revision.. hoyer heights reconstruction.\ f in a lp la n \1 2 0 6 7 _ ln 0 1.d g n lp 600d2317 lp 600d4569 scj 47256 sean c. jergens of the state of minnesota.

DA

TE P

RIN

TE

D =

1/1

6/2

020

5:5

9:4

3 P

MFIL

E N

AM

E =

DATELIC. NO.

DATE:

DATE:

DATE:

DRW:

CHK:

APP:

OF

NO. DATE DRW APPCKD REVISION

HOYER HEIGHTS RECONSTRUCTION...\FinalPla

n\1

2067_ln

01.d

gn

LP 600D4569LP 600D2317

SCJ

47256

SEAN C. JERGENS

OF THE STATE OF MINNESOTA.PROFESSIONAL LANDSCAPE ARCHITECT UNDER THE LAWS SUPERVISION AND THAT I AM A DULY LICENSEDREPORT WAS PREPARED BY ME OR UNDER MY DIRECTI HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION, OR

12/18/19

1/14/2020

SCJ

RB 1/14/2020

1/14/2020

MH

10 11

12

13

MH

MH

MH

MH MH

1415 16 17

90

100

101

XX

12

LEGEND

QUANTITY

PLANT SPECIES TO REMAIN

EXISTING TREE

SEE STORM SEWER PLANS

TREE TRENCH CURB CUT, TYP.

DECIDUOUS TREESEE SHEETS -

PERENNIAL PLANTINGS

112 114

CONSTR. PLANS

SOD - SEE

LANDSCAPE GENERAL NOTES:

8.

7.

6.

5.

4.

3.

2.

1.

REFER TO PROJECT SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.

PLANTING.

FIELD. LANDSCAPE ARCHITECT SHALL APPROVE LOCATIONS BEFORE

PLAN AND ADJUST IF NECESSARY TO AVOID UTILITY CONFLICTS IN THE

CONTRACTOR TO STAKE ALL TREES AND PERENNIAL PLANTING BEDS PER

ARCHITECT FOR DIRECTION PRIOR TO PROCEEDING.

REPORT ALL LAYOUT DISCREPANCIES IMMEDIATELY TO THE LANDSCAPE

COMMENCING.

UNDERGROUND UTILITIES ACCORDING TO STATE LAW PRIOR TO ANY WORK

CONTRACTOR SHALL COORDINATE LOCATION AND MARKING OF ALL

SEE PLANT SCHEDULE ON SHEET .

AND LANDSCAPE INSTALLATION.

RESTORE ALL TURF AREAS THAT ARE DISTURBED DURING CONSTRUCTION

ETC. THAT ARE TO REMAIN.

PROTECT ALL EXISTING STRUCTURES, UTILITIES, TREES, SITE AMENITIES,

AND START OF CONSTRUCTION.

THE CONTRACTOR SHALL VERIFY EXISTING CONDITIONS PRIOR TO BIDDING

117

106

134

ALIGN 36 1/2 AVE NE

ALIGN 36 1/2 AVE NE

ALIGN TAYLOR ST NE

ALIGN FILLMORE ST NE

37T

H A

VE N

E

POLK ST N

E

SEE BELOW

MATCH LINE - STA 13+10.0

SE

E A

BO

VE

MA

TC

H LIN

E - S

TA 1

3+10.0

0

HORIZONTAL SCALE IN FEET

20 40

SCALE 40

0

HORIZONTAL SCALE IN FEET

20 40

SCALE 40

LANDSCAPING PLANS

BEGIN PROJECT TO 36 1/2 AVE NE STA 16+50

LEGENDNUMBER

ITEMDESCRIPTION UNIT

TOTAL

ESTIMATED

112

112

SEE STORM SEWER PLANS

CURB CUT, TYP.

SEE SHEETMATCH LINE - STA 89+60.0

108

108

SEE SHEETMATCH LINE - STA 92+0.0

107

SE

E S

HE

ET

MA

TC

H LIN

E S

TA 1

6+50.0

108

SEE SHEETMATCH LINE - STA 100+45.0 PLAN A ON SHEET

SEE TREE TRENCH ENLARGEMENT

PLAN C ON SHEET

SEE TREE TRENCH ENLARGEMENT

(NO LANDSCAPE QUANTITIES THIS SHEET)

Page 2: OF - mwmo.orgdate drw ckd app revision.. hoyer heights reconstruction.\ f in a lp la n \1 2 0 6 7 _ ln 0 1.d g n lp 600d2317 lp 600d4569 scj 47256 sean c. jergens of the state of minnesota.

DA

TE P

RIN

TE

D =

1/1

6/2

020

5:5

9:4

5 P

MFIL

E N

AM

E =

DATELIC. NO.

DATE:

DATE:

DATE:

DRW:

CHK:

APP:

OF

NO. DATE DRW APPCKD REVISION

HOYER HEIGHTS RECONSTRUCTION...\FinalPla

n\1

2067_ln

02.d

gn

LP 600D4569LP 600D2317

SCJ

47256

SEAN C. JERGENS

OF THE STATE OF MINNESOTA.PROFESSIONAL LANDSCAPE ARCHITECT UNDER THE LAWS SUPERVISION AND THAT I AM A DULY LICENSEDREPORT WAS PREPARED BY ME OR UNDER MY DIRECTI HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION, OR

12/18/19

1/14/2020

SCJ

RB 1/14/2020

1/14/2020

MH

MH

20

21 22

70

71

MH

MH

MH

MH

MH

MH

17 18 19

80

XX

12

LEGEND

QUANTITY

PLANT SPECIES TO REMAIN

EXISTING TREE

SEE STORM SEWER PLANS

TREE TRENCH CURB CUT, TYP.

DECIDUOUS TREESEE SHEETS -

PERENNIAL PLANTINGS

112 114

CONSTR. PLANS

SOD - SEE

LANDSCAPE GENERAL NOTES:

8.

7.

6.

5.

4.

3.

2.

1.

REFER TO PROJECT SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.

PLANTING.

FIELD. LANDSCAPE ARCHITECT SHALL APPROVE LOCATIONS BEFORE

PLAN AND ADJUST IF NECESSARY TO AVOID UTILITY CONFLICTS IN THE

CONTRACTOR TO STAKE ALL TREES AND PERENNIAL PLANTING BEDS PER

ARCHITECT FOR DIRECTION PRIOR TO PROCEEDING.

REPORT ALL LAYOUT DISCREPANCIES IMMEDIATELY TO THE LANDSCAPE

COMMENCING.

UNDERGROUND UTILITIES ACCORDING TO STATE LAW PRIOR TO ANY WORK

CONTRACTOR SHALL COORDINATE LOCATION AND MARKING OF ALL

SEE PLANT SCHEDULE ON SHEET .

AND LANDSCAPE INSTALLATION.

RESTORE ALL TURF AREAS THAT ARE DISTURBED DURING CONSTRUCTION

ETC. THAT ARE TO REMAIN.

PROTECT ALL EXISTING STRUCTURES, UTILITIES, TREES, SITE AMENITIES,

AND START OF CONSTRUCTION.

THE CONTRACTOR SHALL VERIFY EXISTING CONDITIONS PRIOR TO BIDDING

117

107

134

ALIGN 36 1/2 AVE NE

ALIGN 36 1/2 AVE NE

ALIGN PIERCE ST NE

SE

E A

BO

VE

MA

TC

H LIN

E S

TA 1

9+68.0

SE

E B

EL

OW

MA

TC

H LIN

E S

TA 1

9+68.0

0

HORIZONTAL SCALE IN FEET

20 40

SCALE 40

0

HORIZONTAL SCALE IN FEET

20 40

SCALE 40

SE

E S

HE

ET 106

MA

TC

H LIN

E S

TA 1

6+50.0

LANDSCAPING PLANS

36 1/2 AVE NE STA 16+50 TO STA 22+19

LEGENDNUMBER

ITEMDESCRIPTION UNIT

TOTAL

ESTIMATED

(NO LANDSCAPE QUANTITIES THIS SHEET)

SEE SHEETMATCH LIN

E - STA 80+47.0

109

SEE SHEETMATCH LINE - STA 70+38.0

109

SE

E S

HE

ET

MA

TC

H LIN

E - S

TA 2

2+19.0

110

Page 3: OF - mwmo.orgdate drw ckd app revision.. hoyer heights reconstruction.\ f in a lp la n \1 2 0 6 7 _ ln 0 1.d g n lp 600d2317 lp 600d4569 scj 47256 sean c. jergens of the state of minnesota.

DA

TE P

RIN

TE

D =

1/1

6/2

020

5:5

9:4

7 P

MFIL

E N

AM

E =

DATELIC. NO.

DATE:

DATE:

DATE:

DRW:

CHK:

APP:

OF

NO. DATE DRW APPCKD REVISION

HOYER HEIGHTS RECONSTRUCTION...\FinalPla

n\1

2067_ln

03.d

gn

LP 600D4569LP 600D2317

SCJ

47256

SEAN C. JERGENS

OF THE STATE OF MINNESOTA.PROFESSIONAL LANDSCAPE ARCHITECT UNDER THE LAWS SUPERVISION AND THAT I AM A DULY LICENSEDREPORT WAS PREPARED BY ME OR UNDER MY DIRECTI HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION, OR

12/18/19

1/14/2020

SCJ

RB 1/14/2020

1/14/2020

101 102

MHMH M

H

16

89 90 91 92

XX

12

LEGEND

QUANTITY

PLANT SPECIES TO REMAIN

EXISTING TREE

SEE STORM SEWER PLANS

TREE TRENCH CURB CUT, TYP.

DECIDUOUS TREESEE SHEETS -

PERENNIAL PLANTINGS

112 114

CONSTR. PLANS

SOD - SEE

LANDSCAPE GENERAL NOTES:

8.

7.

6.

5.

4.

3.

2.

1.

REFER TO PROJECT SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.

PLANTING.

FIELD. LANDSCAPE ARCHITECT SHALL APPROVE LOCATIONS BEFORE

PLAN AND ADJUST IF NECESSARY TO AVOID UTILITY CONFLICTS IN THE

CONTRACTOR TO STAKE ALL TREES AND PERENNIAL PLANTING BEDS PER

ARCHITECT FOR DIRECTION PRIOR TO PROCEEDING.

REPORT ALL LAYOUT DISCREPANCIES IMMEDIATELY TO THE LANDSCAPE

COMMENCING.

UNDERGROUND UTILITIES ACCORDING TO STATE LAW PRIOR TO ANY WORK

CONTRACTOR SHALL COORDINATE LOCATION AND MARKING OF ALL

SEE PLANT SCHEDULE ON SHEET .

AND LANDSCAPE INSTALLATION.

RESTORE ALL TURF AREAS THAT ARE DISTURBED DURING CONSTRUCTION

ETC. THAT ARE TO REMAIN.

PROTECT ALL EXISTING STRUCTURES, UTILITIES, TREES, SITE AMENITIES,

AND START OF CONSTRUCTION.

THE CONTRACTOR SHALL VERIFY EXISTING CONDITIONS PRIOR TO BIDDING

117

108

134

ALIGN 36 1/2 AVE NE

ALIGN FILLMORE ST NE

ALIGN TAYLOR ST NE

37T

H A

VE N

E

37T

H A

VE N

E

0

HORIZONTAL SCALE IN FEET

20 40

SCALE 40

0

HORIZONTAL SCALE IN FEET

20

SCALE 40

LANDSCAPING PLANS

TAYLOR ST NE & FILLMORE STREET NE; SOUTH END TO STA 89+60.0, STA 90+83.0 NORTH END

LEGENDNUMBER

ITEMDESCRIPTION UNIT

TOTAL

ESTIMATED

112

112

SEE STORM SEWER PLANS

CURB CUT, TYP.

SE

E S

HE

ET

MA

TC

H LIN

E - S

TA 1

00+45.0

106

SWO

4

34'-0"

34'-0"

15'-0" 34'-0"15'-0" 16'-6"

17'-6"18'-6"

23'-0"

ELM

1

LPT

3

BTU

2PLAN B ON SHEET

SEE TREE TRENCH ENLARGEMENT

PLAN C ON SHEET

SEE TREE TRENCH ENLARGEMENT

112PLAN D ON SHEET

SEE TREE TRENCH ENLARGEMENT

112

112

EDGER, TYP.

LANDSCAPE

11'-3"

EDGER, TYP.

LANDSCAPE

112PLAN A ON SHEET

SEE TREE TRENCH ENLARGEMENT

10'

LANDSCAPE EDGER, TYP.

N/A 2571.524

32

TREE 10DECIDUOUS TREE 2.5" CAL B&B

PLAN C ON SHEET

SEE TREE TRENCH ENLARGEMENT

PLAN A ON SHEET

SEE TREE TRENCH ENLARGEMENT

2540.524N/A LANDSCAPE EDGER LIN FT

Page 4: OF - mwmo.orgdate drw ckd app revision.. hoyer heights reconstruction.\ f in a lp la n \1 2 0 6 7 _ ln 0 1.d g n lp 600d2317 lp 600d4569 scj 47256 sean c. jergens of the state of minnesota.

DA

TE P

RIN

TE

D =

1/1

6/2

020

5:5

9:4

9 P

MFIL

E N

AM

E =

DATELIC. NO.

DATE:

DATE:

DATE:

DRW:

CHK:

APP:

OF

NO. DATE DRW APPCKD REVISION

HOYER HEIGHTS RECONSTRUCTION...\FinalPla

n\1

2067_ln

04.d

gn

LP 600D4569LP 600D2317

SCJ

47256

SEAN C. JERGENS

OF THE STATE OF MINNESOTA.PROFESSIONAL LANDSCAPE ARCHITECT UNDER THE LAWS SUPERVISION AND THAT I AM A DULY LICENSEDREPORT WAS PREPARED BY ME OR UNDER MY DIRECTI HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION, OR

12/18/19

1/14/2020

SCJ

RB 1/14/2020

1/14/2020

MH

MH

81 82 83

71 72 73

XX

12

LEGEND

QUANTITY

PLANT SPECIES TO REMAIN

EXISTING TREE

SEE STORM SEWER PLANS

TREE TRENCH CURB CUT, TYP.

DECIDUOUS TREESEE SHEETS -

PERENNIAL PLANTINGS

112 114

CONSTR. PLANS

SOD - SEE

LANDSCAPE GENERAL NOTES:

8.

7.

6.

5.

4.

3.

2.

1.

REFER TO PROJECT SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.

PLANTING.

FIELD. LANDSCAPE ARCHITECT SHALL APPROVE LOCATIONS BEFORE

PLAN AND ADJUST IF NECESSARY TO AVOID UTILITY CONFLICTS IN THE

CONTRACTOR TO STAKE ALL TREES AND PERENNIAL PLANTING BEDS PER

ARCHITECT FOR DIRECTION PRIOR TO PROCEEDING.

REPORT ALL LAYOUT DISCREPANCIES IMMEDIATELY TO THE LANDSCAPE

COMMENCING.

UNDERGROUND UTILITIES ACCORDING TO STATE LAW PRIOR TO ANY WORK

CONTRACTOR SHALL COORDINATE LOCATION AND MARKING OF ALL

SEE PLANT SCHEDULE ON SHEET .

AND LANDSCAPE INSTALLATION.

RESTORE ALL TURF AREAS THAT ARE DISTURBED DURING CONSTRUCTION

ETC. THAT ARE TO REMAIN.

PROTECT ALL EXISTING STRUCTURES, UTILITIES, TREES, SITE AMENITIES,

AND START OF CONSTRUCTION.

THE CONTRACTOR SHALL VERIFY EXISTING CONDITIONS PRIOR TO BIDDING

117

109

134

37T

H A

VE N

E37T

H A

VE N

E

0

HORIZONTAL SCALE IN FEET

20 40

SCALE 40

0

HORIZONTAL SCALE IN FEET

20 40

SCALE 40

LANDSCAPING PLANS

PIERCE ST NE & PIERCE PL NE

LEGENDNUMBER

ITEMDESCRIPTION UNIT

TOTAL

ESTIMATED

SE

E S

HE

ET

MA

TC

H LIN

E - S

TA 8

0+47.0

107

107

SE

E S

HE

ET

MA

TC

H LIN

E - S

TA 7

0+38.0

(NO LANDSCAPE QUANTITIES THIS SHEET)

ALIGN PIERCE ST NE

ALIGN PIERCE PL NE

Page 5: OF - mwmo.orgdate drw ckd app revision.. hoyer heights reconstruction.\ f in a lp la n \1 2 0 6 7 _ ln 0 1.d g n lp 600d2317 lp 600d4569 scj 47256 sean c. jergens of the state of minnesota.

DA

TE P

RIN

TE

D =

1/1

6/2

020

5:5

9:5

0 P

MFIL

E N

AM

E =

DATELIC. NO.

DATE:

DATE:

DATE:

DRW:

CHK:

APP:

OF

NO. DATE DRW APPCKD REVISION

HOYER HEIGHTS RECONSTRUCTION...\FinalPla

n\1

2067_ln

05.d

gn

LP 600D4569LP 600D2317

SCJ

47256

SEAN C. JERGENS

OF THE STATE OF MINNESOTA.PROFESSIONAL LANDSCAPE ARCHITECT UNDER THE LAWS SUPERVISION AND THAT I AM A DULY LICENSEDREPORT WAS PREPARED BY ME OR UNDER MY DIRECTI HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION, OR

12/18/19

1/14/2020

SCJ

RB 1/14/2020

1/14/2020

MHMH

DI

DI

59 60 61

62 63

XX

12

LEGEND

QUANTITY

PLANT SPECIES TO REMAIN

EXISTING TREE

SEE STORM SEWER PLANS

TREE TRENCH CURB CUT, TYP.

DECIDUOUS TREESEE SHEETS -

PERENNIAL PLANTINGS

112 114

CONSTR. PLANS

SOD - SEE

LANDSCAPE GENERAL NOTES:

8.

7.

6.

5.

4.

3.

2.

1.

REFER TO PROJECT SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.

PLANTING.

FIELD. LANDSCAPE ARCHITECT SHALL APPROVE LOCATIONS BEFORE

PLAN AND ADJUST IF NECESSARY TO AVOID UTILITY CONFLICTS IN THE

CONTRACTOR TO STAKE ALL TREES AND PERENNIAL PLANTING BEDS PER

ARCHITECT FOR DIRECTION PRIOR TO PROCEEDING.

REPORT ALL LAYOUT DISCREPANCIES IMMEDIATELY TO THE LANDSCAPE

COMMENCING.

UNDERGROUND UTILITIES ACCORDING TO STATE LAW PRIOR TO ANY WORK

CONTRACTOR SHALL COORDINATE LOCATION AND MARKING OF ALL

SEE PLANT SCHEDULE ON SHEET .

AND LANDSCAPE INSTALLATION.

RESTORE ALL TURF AREAS THAT ARE DISTURBED DURING CONSTRUCTION

ETC. THAT ARE TO REMAIN.

PROTECT ALL EXISTING STRUCTURES, UTILITIES, TREES, SITE AMENITIES,

AND START OF CONSTRUCTION.

THE CONTRACTOR SHALL VERIFY EXISTING CONDITIONS PRIOR TO BIDDING

117

110

134

ALIGN BUCHANAN ST NE

ALIGN BUCHANAN ST NE

ALIGN 36 1/2 AVE NE

37T

H A

VE N

E

SE

E A

BO

VE

MA

TC

H LIN

E S

TA 6

1+47.0

SE

E B

EL

OW

MA

TC

H LIN

E S

TA 6

1+47.0

0

HORIZONTAL SCALE IN FEET

20 40

SCALE 40

0

HORIZONTAL SCALE IN FEET

20 40

SCALE 40

BUCHANAN ST NE

LEGENDNUMBER

ITEMDESCRIPTION UNIT

TOTAL

ESTIMATED

8

32'-0"

38'-0"

13'

34'-0"

8'-4"

SEE STORM SEWER PLANS

CURB CUT, TYP.

SEE STORM SEWER PLANS

CURB CUT, TYP.

LANDSCAPE PLANS

ELM

2

SWO

2

RSM

1

RSM

2

107SEE SHEETMATCH LINE STA 22+19.0

18'-3"

PLAN E ON SHEET

SEE TREE TRENCH ENLARGEMENT

PLAN F ON SHEET

SEE TREE TRENCH ENLARGEMENT

PLAN E ON SHEET

SEE TREE TRENCH ENLARGEMENT

EDGER, TYP.

LANDSCAPE

113

2540.603 LANDSCAPE EDGER LIN FTN/A

N/A 2571.524 5DECIDUOUS TREE TREE

888

113

113

Page 6: OF - mwmo.orgdate drw ckd app revision.. hoyer heights reconstruction.\ f in a lp la n \1 2 0 6 7 _ ln 0 1.d g n lp 600d2317 lp 600d4569 scj 47256 sean c. jergens of the state of minnesota.

DA

TE P

RIN

TE

D =

1/1

6/2

020

5:5

9:5

2 P

MFIL

E N

AM

E =

DATELIC. NO.

DATE:

DATE:

DATE:

DRW:

CHK:

APP:

OF

NO. DATE DRW APPCKD REVISION

HOYER HEIGHTS RECONSTRUCTION...\FinalPla

n\1

2067_ln

06.d

gn

LP 600D4569LP 600D2317

SCJ

47256

SEAN C. JERGENS

OF THE STATE OF MINNESOTA.PROFESSIONAL LANDSCAPE ARCHITECT UNDER THE LAWS SUPERVISION AND THAT I AM A DULY LICENSEDREPORT WAS PREPARED BY ME OR UNDER MY DIRECTI HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION, OR

12/18/19

1/14/2020

SCJ

RB 1/14/2020

1/14/2020

DI

DIMH

50 51 52

53 54 55

XX

12

LEGEND

QUANTITY

PLANT SPECIES TO REMAIN

EXISTING TREE

SEE STORM SEWER PLANS

TREE TRENCH CURB CUT, TYP.

DECIDUOUS TREESEE SHEETS -

PERENNIAL PLANTINGS

112 114

CONSTR. PLANS

SOD - SEE

LANDSCAPE GENERAL NOTES:

8.

7.

6.

5.

4.

3.

2.

1.

REFER TO PROJECT SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.

PLANTING.

FIELD. LANDSCAPE ARCHITECT SHALL APPROVE LOCATIONS BEFORE

PLAN AND ADJUST IF NECESSARY TO AVOID UTILITY CONFLICTS IN THE

CONTRACTOR TO STAKE ALL TREES AND PERENNIAL PLANTING BEDS PER

ARCHITECT FOR DIRECTION PRIOR TO PROCEEDING.

REPORT ALL LAYOUT DISCREPANCIES IMMEDIATELY TO THE LANDSCAPE

COMMENCING.

UNDERGROUND UTILITIES ACCORDING TO STATE LAW PRIOR TO ANY WORK

CONTRACTOR SHALL COORDINATE LOCATION AND MARKING OF ALL

SEE PLANT SCHEDULE ON SHEET .

AND LANDSCAPE INSTALLATION.

RESTORE ALL TURF AREAS THAT ARE DISTURBED DURING CONSTRUCTION

ETC. THAT ARE TO REMAIN.

PROTECT ALL EXISTING STRUCTURES, UTILITIES, TREES, SITE AMENITIES,

AND START OF CONSTRUCTION.

THE CONTRACTOR SHALL VERIFY EXISTING CONDITIONS PRIOR TO BIDDING

117

134

ALIGN LINCOLN ST NE

ALIGN LINCOLN ST NE

37T

H A

VE N

E

111

SE

E B

EL

OW

MA

TC

H LIN

E S

TA 5

2+56.0

SE

E A

BO

VE

MA

TC

H LIN

E S

TA 5

2+56.0

0

HORIZONTAL SCALE IN FEET

20 40

SCALE 40

0

HORIZONTAL SCALE IN FEET

20 40

SCALE 40

LANDSCAPING PLANS

HB

1

HB

3

8'-6"

16'-6"

SEE STORM SEWER PLANS

CURB CUT, TYP.

114PLAN H ON SHEET

SEE TREE TRENCH ENLARGEMENT

PLAN G ON SHEET

SEE TREE TRENCH ENLARGEMENT

11424'-0" 22'-0"

BUCHANAN ST NE

LEGENDNUMBER

ITEMDESCRIPTION UNIT

TOTAL

ESTIMATED

122540.603 LANDSCAPE EDGER LIN FTN/A

N/A 2571.524 4DECIDUOUS TREE TREE

888

Page 7: OF - mwmo.orgdate drw ckd app revision.. hoyer heights reconstruction.\ f in a lp la n \1 2 0 6 7 _ ln 0 1.d g n lp 600d2317 lp 600d4569 scj 47256 sean c. jergens of the state of minnesota.

DA

TE P

RIN

TE

D =

1/1

6/2

020

5:5

9:5

4 P

MFIL

E N

AM

E =

DATELIC. NO.

DATE:

DATE:

DATE:

DRW:

CHK:

APP:

OF

NO. DATE DRW APPCKD REVISION

HOYER HEIGHTS RECONSTRUCTION...\FinalPla

n\1

2067_ln

07.d

gn

LP 600D4569LP 600D2317

SCJ

47256

SEAN C. JERGENS

OF THE STATE OF MINNESOTA.PROFESSIONAL LANDSCAPE ARCHITECT UNDER THE LAWS SUPERVISION AND THAT I AM A DULY LICENSEDREPORT WAS PREPARED BY ME OR UNDER MY DIRECTI HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION, OR

12/18/19

1/14/2020

SCJ

RB 1/14/2020

1/14/2020

MH MH

16

89 90 91

MH MH

16

89 90 91

92

92 LANDSCAPE GENERAL NOTES:

8.

7.

6.

5.

4.

3.

2.

1.

REFER TO PROJECT SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.

PLANTING.

FIELD. LANDSCAPE ARCHITECT SHALL APPROVE LOCATIONS BEFORE

PLAN AND ADJUST IF NECESSARY TO AVOID UTILITY CONFLICTS IN THE

CONTRACTOR TO STAKE ALL TREES AND PERENNIAL PLANTING BEDS PER

ARCHITECT FOR DIRECTION PRIOR TO PROCEEDING.

REPORT ALL LAYOUT DISCREPANCIES IMMEDIATELY TO THE LANDSCAPE

COMMENCING.

UNDERGROUND UTILITIES ACCORDING TO STATE LAW PRIOR TO ANY WORK

CONTRACTOR SHALL COORDINATE LOCATION AND MARKING OF ALL

SEE PLANT SCHEDULE ON SHEET .

AND LANDSCAPE INSTALLATION.

RESTORE ALL TURF AREAS THAT ARE DISTURBED DURING CONSTRUCTION

ETC. THAT ARE TO REMAIN.

PROTECT ALL EXISTING STRUCTURES, UTILITIES, TREES, SITE AMENITIES,

AND START OF CONSTRUCTION.

THE CONTRACTOR SHALL VERIFY EXISTING CONDITIONS PRIOR TO BIDDING

117

134

0

HORIZONTAL SCALE IN FEET

112

10 20

SCALE 20

ALIGN 36 1/2 AVE NE

ALIGN FILLMORE ST NE

ALIGN FILLMORE ST NE

ALIGN FILLMORE ST NE

LANDSCAPE PLANS

TREE TRENCH ENLARGEMENT PLAN A

TREE TRENCH ENLARGEMENT PLAN CTREE TRENCH ENLARGEMENT PLAN B

TREE TRENCH ENLARGEMENT PLAN D

IRI

13

HLB

9

BAB

9

PDS

19

BAB

5

PDS

4

BES

5

MON

9

HLB

8

BFM

3

PCF

4

BAB

5

PDS

28

KBS

5

BFM

11

MON

8

HLB

15

JPW

5

KBS

8

BES

5

PDS

6

PCF

5

MON

6

PDS

10

PDS

14

BAB

8

BFM

5

JPW

8

PDS

12

MON

9

PCF

3MON

3

HLB

10

IRI

12

ING

6

KBS

6

BES

6

PDS

9

HLB

6

BES

3

BAB

8

PDS

6

PCF

12

BES

5

MON

8

JPW

6

PDS

8

BAB

6

BFM

5

PDS

30

PCF

6

IRI

8

HLB

10

KBS

6

BES

5

BFM

5

BAB

14

BES

5

PDS

21

BES

5

PCF

6

IRI

8

BES

7

BAB

5

HLB

15

BFM

7

PDS

13

BES

9

IRI

12PCF

7

PDS

27

JPW

8

PDS

10

BES

6

MON

3

PDS

4

PCF

5

BES

5

KBS

6

JPW

9

PDS

12

BES

7

ING

12

PCF

6

KBS

6

BAB

9

BFM

5

BES

6

HLB

10

HLB

18

IRI

7

MON

5

PDS

19

KBS

10

PCF

4

BES

6

BFM

3

HLB

6

PDS

6

BFM

3

BES

6

PCF

21

KBS

6

BES

4

MON

8

PDS

21

BES

6

PCF

9

BES

5HLB

5

PDS

29

IRI

12

ARRANGEMENT AT 12" ON CENTER

(212) 4" CONT PERENNIALS - RANDOM

BLS

32

CAN

32

COR

32

FXS

42

LLB

21

PAR

32

PPC

21ARRANGEMENT AT 12" ON CENTER

(120) 4" CONT PERENNIALS - RANDOM

BLS

18

CAN

18

COR

18

FXS

24

LLB

12

PAR

18

PPC

12

BLS

12

CAN

12

COR

12

FXS

16

LLB

7

PAR

12

PPC

7

ARRANGEMENT AT 12" ON CENTER

(78) 4" CONT PERENNIALS - RANDOM

ARRANGEMENT AT 12" ON CENTER

(120) 4" CONT PERENNIALS - RANDOM

BLS

18

CAN

18

COR

18

FXS

24

LLB

12

PAR

18

PPC

12

ARRANGEMENT AT 12" ON CENTER

(234) 4" CONT PERENNIALS - RANDOM

BLS

35

CAN

35

COR

35

FXS

48

LLB

23

PAR

35

PPC

23

BLS

12

CAN

12

COR

12

FXS

16

LLB

8

PAR

12

PPC

8

ARRANGEMENT AT 12" ON CENTER

(80) 4" CONT PERENNIALS - RANDOM

ARRANGEMENT AT 12" ON CENTER

(175) 4" CONT PERENNIALS - RANDOM

BLS

26

CAN

26

COR

26

FXS

35

LLB

18

PAR

26

PPC

18

ARRANGEMENT AT 12" ON CENTER

(78) 4" CONT PERENNIALS - RANDOM

BLS

12

CAN

12

COR

12

FXS

16

LLB

7

PAR

12

PPC

7

LEGENDNUMBER

ITEMDESCRIPTION UNIT

TOTAL

ESTIMATED

FILLMORE STREET NE

PERENNIAL 4" CONT2571.527N/A

N/A 2571.527 PLANT

PLANT

PERENNIAL NO 1 CONT

PDS

9

PDS

14

KBS

6

IRI

4

KBS

6

BAB

8

IRI

10

ALIGN FILLMORE ST NE

1097

1017

XX

12

LEGEND

QUANTITY

PLANT SPECIES TO REMAIN

EXISTING TREE

SEE STORM SEWER PLANS

TREE TRENCH CURB CUT, TYP.

106 111

CONSTR. PLANS

SOD - SEE

SEE SHEETS -

DECIDUOUS TREE

PROPOSED

4" CONT. PERENNIALS

#1 CONT. PERENNIALS

Page 8: OF - mwmo.orgdate drw ckd app revision.. hoyer heights reconstruction.\ f in a lp la n \1 2 0 6 7 _ ln 0 1.d g n lp 600d2317 lp 600d4569 scj 47256 sean c. jergens of the state of minnesota.

DA

TE P

RIN

TE

D =

1/1

6/2

020

5:5

9:5

5 P

MFIL

E N

AM

E =

DATELIC. NO.

DATE:

DATE:

DATE:

DRW:

CHK:

APP:

OF

NO. DATE DRW APPCKD REVISION

HOYER HEIGHTS RECONSTRUCTION...\FinalPla

n\1

2067_ln

08.d

gn

LP 600D4569LP 600D2317

SCJ

47256

SEAN C. JERGENS

OF THE STATE OF MINNESOTA.PROFESSIONAL LANDSCAPE ARCHITECT UNDER THE LAWS SUPERVISION AND THAT I AM A DULY LICENSEDREPORT WAS PREPARED BY ME OR UNDER MY DIRECTI HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION, OR

12/18/19

1/14/2020

SCJ

RB 1/14/2020

1/14/2020

MH

61 62

MH

60XX

12

LEGEND

QUANTITY

PLANT SPECIES TO REMAIN

EXISTING TREE

SEE STORM SEWER PLANS

TREE TRENCH CURB CUT, TYP.

LANDSCAPE GENERAL NOTES:

106 111

CONSTR. PLANS

SOD - SEE

SEE SHEETS -

DECIDUOUS TREE

PROPOSED

4" CONT. PERENNIALS

#1 CONT. PERENNIALS

8.

7.

6.

5.

4.

3.

2.

1.

REFER TO PROJECT SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.

PLANTING.

FIELD. LANDSCAPE ARCHITECT SHALL APPROVE LOCATIONS BEFORE

PLAN AND ADJUST IF NECESSARY TO AVOID UTILITY CONFLICTS IN THE

CONTRACTOR TO STAKE ALL TREES AND PERENNIAL PLANTING BEDS PER

ARCHITECT FOR DIRECTION PRIOR TO PROCEEDING.

REPORT ALL LAYOUT DISCREPANCIES IMMEDIATELY TO THE LANDSCAPE

COMMENCING.

UNDERGROUND UTILITIES ACCORDING TO STATE LAW PRIOR TO ANY WORK

CONTRACTOR SHALL COORDINATE LOCATION AND MARKING OF ALL

SEE PLANT SCHEDULE ON SHEET .

AND LANDSCAPE INSTALLATION.

RESTORE ALL TURF AREAS THAT ARE DISTURBED DURING CONSTRUCTION

ETC. THAT ARE TO REMAIN.

PROTECT ALL EXISTING STRUCTURES, UTILITIES, TREES, SITE AMENITIES,

AND START OF CONSTRUCTION.

THE CONTRACTOR SHALL VERIFY EXISTING CONDITIONS PRIOR TO BIDDING

117

134

0

HORIZONTAL SCALE IN FEET

113

10 20

SCALE 20

LANDSCAPE PLANS

36 1/2 A

VE N

E

ALIGN BUCHANAN ST NE

ALIGN BUCHANAN ST NE

SB BUCHANAN ST NE

NB BUCHANAN ST NE

TREE TRENCH ENLARGEMENT PLAN E

TREE TRENCH ENLARGEMENT PLAN F

HLB

6 PDS

29

MON

5

KBS

8

BES

7

MON

4

PDS

18

BAB

5

BFM

3

PCF

9

HLB

6

BES

5

JPW

7

MON

4

IRI

8

ING

8

IRI

8

BES

9KBS

5

PDS

7

IRI

9

HLB

6

MON

5

BAB

5

BAB

6

HLB

8

BES

4

PCF

8

KBS

7

PDS

13

HLB

6

BFM

3

BFM

5

PDS

24

MON

5

BAB

5

BES

6

HLB

9

PCF

14PCF

10

BES

6

BFM

5

BAB

7

HLB

3

IRI

8

ING

8

MON

8

IRI

8HLB

3

BAB

6

KBS

5

PDS

35

PDS

13

FXS

7

BFM

3

BES

8

JPW

5

CAN

8

PDS

8

BES

8

JPW

7BFM

3

HLB

3

PDS

14

BES

5

PCF

7

IRI

10

BAB

7

MON

5

PDS

13

BAB

7

HLB

7

BAB

7

BES

4

PCF

3

PDS

9

KBS

3

BES

3

ARRANGEMENT AT 12" ON CENTER

(87) 4" CONT PERENNIALS - RANDOM

BLS

13

CAN

13

COR

13

FXS

17

LLB

9

PAR

13

PPC

9

BLS

20

CAN

20

COR

20

FXS

26

LLB

13

PAR

20

PPC

13

ARRANGEMENT AT 12" ON CENTER

(132) 4" CONT PERENNIALS - RANDOM

BLS

17

CAN

17

COR

17

FXS

22

LLB

10

PAR

17

PPC

10

ARRANGEMENT AT 12" ON CENTER

(110) 4" CONT PERENNIALS - RANDOM

BLS

21

CAN

21

COR

21

FXS

28

LLB

14

PAR

21

PPC

14

ARRANGEMENT AT 12" ON CENTER

(140) 4" CONT PERENNIALS - RANDOMARRANGEMENT AT 12" ON CENTER

(132) 4" CONT PERENNIALS - RANDOM

BLS

20

CAN

20

COR

20

FXS

26

LLB

13

PAR

20

PPC

13

LEGENDNUMBER

ITEMDESCRIPTION UNIT

TOTAL

ESTIMATED

PERENNIAL 4" CONT2571.527N/A

N/A 2571.527 PLANT

PLANT

PERENNIAL NO 1 CONT

BUCHANAN STREET NE

PCF

7

IRI

9

PDS

14

BAB

7

IRI

4

IRI

4

BFM

3

616

631

Page 9: OF - mwmo.orgdate drw ckd app revision.. hoyer heights reconstruction.\ f in a lp la n \1 2 0 6 7 _ ln 0 1.d g n lp 600d2317 lp 600d4569 scj 47256 sean c. jergens of the state of minnesota.

DA

TE P

RIN

TE

D =

1/1

6/2

020

5:5

9:5

7 P

MFIL

E N

AM

E =

DATELIC. NO.

DATE:

DATE:

DATE:

DRW:

CHK:

APP:

OF

NO. DATE DRW APPCKD REVISION

HOYER HEIGHTS RECONSTRUCTION...\FinalPla

n\1

2067_ln

09.d

gn

LP 600D4569LP 600D2317

SCJ

47256

SEAN C. JERGENS

OF THE STATE OF MINNESOTA.PROFESSIONAL LANDSCAPE ARCHITECT UNDER THE LAWS SUPERVISION AND THAT I AM A DULY LICENSEDREPORT WAS PREPARED BY ME OR UNDER MY DIRECTI HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION, OR

12/18/19

1/14/2020

SCJ

RB 1/14/2020

1/14/2020

54 55

51 52

XX

12

LEGEND

QUANTITY

PLANT SPECIES TO REMAIN

EXISTING TREE

SEE STORM SEWER PLANS

TREE TRENCH CURB CUT, TYP.

LANDSCAPE GENERAL NOTES:

106 111

CONSTR. PLANS

SOD - SEE

SEE SHEETS -

DECIDUOUS TREE

PROPOSED

4" CONT. PERENNIALS

#1 CONT. PERENNIALS

8.

7.

6.

5.

4.

3.

2.

1.

REFER TO PROJECT SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.

PLANTING.

FIELD. LANDSCAPE ARCHITECT SHALL APPROVE LOCATIONS BEFORE

PLAN AND ADJUST IF NECESSARY TO AVOID UTILITY CONFLICTS IN THE

CONTRACTOR TO STAKE ALL TREES AND PERENNIAL PLANTING BEDS PER

ARCHITECT FOR DIRECTION PRIOR TO PROCEEDING.

REPORT ALL LAYOUT DISCREPANCIES IMMEDIATELY TO THE LANDSCAPE

COMMENCING.

UNDERGROUND UTILITIES ACCORDING TO STATE LAW PRIOR TO ANY WORK

CONTRACTOR SHALL COORDINATE LOCATION AND MARKING OF ALL

SEE PLANT SCHEDULE ON SHEET .

AND LANDSCAPE INSTALLATION.

RESTORE ALL TURF AREAS THAT ARE DISTURBED DURING CONSTRUCTION

ETC. THAT ARE TO REMAIN.

PROTECT ALL EXISTING STRUCTURES, UTILITIES, TREES, SITE AMENITIES,

AND START OF CONSTRUCTION.

THE CONTRACTOR SHALL VERIFY EXISTING CONDITIONS PRIOR TO BIDDING

117

134

0

HORIZONTAL SCALE IN FEET

114

10 20

SCALE 20

LANDSCAPE PLANS

ALIGN LINCOLN ST NE

SB LINCOLN ST NE

ALIGN LINCOLN ST NE

NB LINCOLN ST NE

TREE TRENCH ENLARGEMENT PLAN G

TREE TRENCH ENLARGEMENT PLAN H

BES

3

IRI

7

HLB

3

PCF

3

HLB

13BAB

3

IRI

8

HLB

3

BFM

3

BES

9

BAB

9

KBS

7

PDS

11

BES

4

HLB

9

BFM

5

JPW

5

KBS

6

IRI

22

KBS

3

BES

10

BES

6

BAB

8

BES

4

HLB

3

KBS

8

PCF

10

PDS

13

BES

7

CAN

6

BFM

3

HLB

5

BFM

3

BAB

3

CAN

6

MON

3

PDS

15

HLB

3

BES

3

PCF

8

PDS

9

IRI

8

BES

7

BFM

3

CAN

6

PDS

3

PCF

6

MON

7

PCF

18

BES

7

KBS

6

MON

13

IRI

20

BES

9

BFM

5

JPW

7

CAN

10

KBS

5

HLB

5

BFM

3

BAB

13

PDS

17

PDS

18

BES

3

IRI

8

PCF

3

KBS

6

HLB

9

BAB

9

PDS

19

JPW

5

PCF

19PCF

15

ARRANGEMENT AT 12" ON CENTER

(265) 4" CONT PERENNIALS - RANDOM

BLS

40

CAN

40

COR

40

FXS

53

LLB

26

PAR

40

PPC

26

BLS

29

CAN

29

COR

29

FXS

40

LLB

20

PAR

29

PPC

20

ARRANGEMENT AT 12" ON CENTER

(196) 4" CONT PERENNIALS - RANDOM

ARRANGEMENT AT 12" ON CENTER

(132) 4" CONT PERENNIALS - RANDOM

BLS

20

CAN

20

COR

20

FXS

26

LLB

13

PAR

20

PPC

13

LEGENDNUMBER

ITEMDESCRIPTION UNIT

TOTAL

ESTIMATED

LINCOLN STREET NE

PERENNIAL 4" CONT2571.527N/A

N/A 2571.527 PLANT

PLANT

PERENNIAL NO 1 CONTPDS

17

PDS

30

MON

5

BES

5

PDS

43

CAN

6KBS

10

627

657

Page 10: OF - mwmo.orgdate drw ckd app revision.. hoyer heights reconstruction.\ f in a lp la n \1 2 0 6 7 _ ln 0 1.d g n lp 600d2317 lp 600d4569 scj 47256 sean c. jergens of the state of minnesota.

DA

TE P

RIN

TE

D =

1/1

6/2

020

5:5

9:5

8 P

MFIL

E N

AM

E =

DATELIC. NO.

DATE:

DATE:

DATE:

DRW:

CHK:

APP:

OF

NO. DATE DRW APPCKD REVISION

HOYER HEIGHTS RECONSTRUCTION...\FinalPla

n\1

2067_ln

10.d

gn

LP 600D4569LP 600D2317

SCJ

47256

SEAN C. JERGENS

OF THE STATE OF MINNESOTA.PROFESSIONAL LANDSCAPE ARCHITECT UNDER THE LAWS SUPERVISION AND THAT I AM A DULY LICENSEDREPORT WAS PREPARED BY ME OR UNDER MY DIRECTI HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION, OR

12/18/19

1/14/2020

SCJ

RB 1/14/2020

1/14/2020

134

LANDSCAPING DETAILS

ACCEPTABLE PLANT STOCK GROWING RANGE LIMITSSOURCE: USDA PLANT HARDINESS ZONE MAP

o

o o

o

CANADA

ND

SD

NE

KS MO

IL IN

OH

MI

MT

WY

CO

PA

NY

MINNESOTA ZONE WHERE THE PROJECT SITE IS LOCATED, AS FOLLOWS:

FOR ALL PLANT STOCK, DOCUMENT ACCEPTABILITY FOR HARDINESS IN THE

YEARS WITHIN THE ACCEPTABLE LIMITS SHOWN.

A.PLANT STOCK CONTINUOUSLY GROWN FOR AT LEAST THE LAST TWO

OR

ORIGINATING FROM THE ACCEPTABLE LIMITS SHOWN.

LIMITS, HAVING SEED SOURCE OR ROOT AND GRAFT STOCK

B.PLANT STOCK, GROWN OUTSIDE THE ACCEPTABLE GROWING RANGE

(MnDOT 3861.2C)

o o -26.1 TO -28.9 F5a

LAKE

LA

KE

LA

KE

LAKE

LAKE

SUPERIOR

MIC

HIG

AN

HU

RO

N

ERIE

ONTANO

5a

5b

4

3

4

2

5a

ZONES LEGEND

UNACCEPTABLE ZONES

2

1

1 0

LA

KE

WIN

NIP

EG BAY

HUDSON

6

6

5b5b

5b and 6

0, 1, 2,

PLANT INSTALLATION PERIOD

PROJECT LOCATION

FALL DECIDUOUS PLANTING DATES.

SPRING NO LATER THAN JUNE 1ST OR FOLLOW THE

1.BARE ROOT PERENNIALS MUST BE INSTALLED IN THE

ENGINEER.

SEASONAL CONDITIONS, AS DETERMINED BY THE

2.ACTUAL DATES MAY CHANGE DEPENDING UPON

CRABAPPLE, PLUM/CHERRY, OAKS, AND SUMAC.

HONEYLOCUST, BIRCH, MOUNTAIN ASH, MAPLE, WILLOW,

DOGWOOD, POPLAR, HACKBERRY, LINDEN, IRONWOOD,

FORM OF THE FOLLOWING SPECIES: HAWTHORN,

3.FALL PLANTING IS NOT ALLOWED FOR BARE ROOT

OF THE PLANT ESTABLISHMENT PERIOD.

DURING THE MONTH OF MAY DURING THE FIRST YEAR

4.ALL REPLACEMENT PLANTS MUST BE INSTALLED

PLANTING DATES BY ZONE

KEYSPRING FALL

DECIDUOUS CONIFEROUS PERENNIALS SEEDLINGS DECIDUOUS CONIFEROUS

APRIL 21 APRIL 21 MAY 1 APRIL 21 OCT. 1 AUG. 25

TO TO TO TO TO TO

JUNE 1 JUNE 1 JUNE 15 JUNE 1 NOV. 1 SEPT. 15

APRIL 7 APRIL 7 MAY 1 APRIL 7 OCT. 10 AUG. 25

TO TO TO TO TO TO

JUNE 1 MAY 17 JUNE 15 MAY 17 NOV. 15 SEPT. 15

3

4

(MnDOT 2571.3F2)

CUT

PRUNING

CORRECT

CLOSE

TOO

LONG

TOO

SLANTED

TOO

PRUNING

BRANCHES PRUNED TO LIVE BUD

BRANCHES PRUNED AT TRUNK(SHIGO METHOD)

A A

(MnDOT 2571.3K2a9 and 2571.3E1)

SAW:

STEPS TO PRUNING WITH PRUNING

BRANCH AT POINT A.

1.CUT PART WAY THROUGH THE

BRANCH FROM POINT B TO A.

2.CUT COMPLETELY THROUGH

POINT C TO D.

3.AT BRANCH COLLAR CUT FROM

AFTER ONE SEASON OF GROWTH.

DISCONTINUOUS CALLUS FORMATION

(TOO CLOSE) WILL RESULT IN

INCORRECT CUT FROM POINT C TO X

GROWTH.

FORMATION AFTER ONE SEASON OF

DOUGHNUT SHAPED CALLUS

WILL RESULT IN CONTINUOUS

THE STUB FROM POINT B TO A)

(LEAVING BRANCH COLLAR BUT NOT

CORRECT CUT FROM POINT C TO D

PRUNING NOTES:

OR PRUNING SAW.

SHARP SCISSOR-TYPE PRUNER

1.PRUNE USING CLEAN AND

EARLY SPRING.

LATE DORMANT SEASON OR

2.THE BEST TIME TO PRUNE IS

MAY, JUNE OR JULY.

3.AVOID PRUNING OAKS IN APRIL,

LATEX PAINT OR SHELLAC.

SURFACE OR WOUND WITH

JULY, IMMEDIATELY PAINT CUT

TREES IN APRIL, MAY, JUNE OR

IF WOUNDS OCCUR TO OAK

4.IF PRUNING IS NECESSARY OR

GENERAL NOTES

SEE SPECIAL PROVISIONS FOR SPECIFIC PROJECT REQUIREMENTS.

GENERAL REQUIREMENTS.

CONTRACT ADMINISTRATION MANUAL FOR MnDOT LANDSCAPE PROJECTS" FOR

REFER TO MnDOT SPECIFICATIONS 2571, 3861, AND THE "2019 INSPECTION AND

COMPLETE PREPARATORY WORK BEFORE STARTING INITIAL PLANTING OPERATIONS.

ACCEPT ALL PLANT STOCK IN ACCORDANCE WITH MnDOT 3861 PRIOR TO PLANTING.

OPERATIONS IN ACCORDANCE WITH (MnDOT 2571.3D2 STEP 4)

THE CONTRACTOR WILL DEMONSTRATE COMPETENCY FOR SOIL CULTIVATION

OPERATIONS IN ACCORDANCE WITH MnDOT 2571.3F1

THE CONTRACTOR WILL DEMONSTRATE COMPETENCY FOR ALL PLANT INSTALLATION

PROTECTION

RODENT

FERTILIZER SEE SPECIAL PROVISIONS

COMPOST MnDOT 3890 GRADE 2 UNLESS OTHERWISE SPECIFIED.

MATERIAL

MULCH MnDOT 3882 TYPE 6 UNLESS OTHERWISE SPECIFIED.

BEDS

PLANTING

MASS

PREVENTION)

CRACK

(FROST

PAINTING

TREENO PAINTING OF TREE STEMS SHALL BE REQUIRED.

DIMENSIONS

PLANTING PLANSTATED DIMENSIONS SUPERCEDE SCALING FROM PLAN.

2571.3G)

(MnDOT

GUIDELINES

WATERING PLANT TYPE WATER PER APPLICATION

AVERAGE GALLONS OF

TREES

MACHINE TRANSPLANTED50-100

TREES

BALLED AND BURLAPPED20

TREES

BARE ROOT AND CONTAINER15

SHRUBS

BALLED AND BURLAPPED10

SHRUBS

BARE ROOT AND CONTAINER7

WOODY SEEDLINGS 4

PERENNIALS AND VINES 3

REQUIREMENTS.

LEVELS. THE AMOUNTS LISTED ABOVE ARE GUIDELINES, NOT

MAINTAIN SOIL MOISTURE AT ADEQUATE BUT NOT EXCESSIVE

IT IS THE CONTRACTOR'S RESPONSIBILITY TO MONITOR AND

ZONES LEGEND MIN. TEMP.

3

4

-34.4 TO -40 F

-28.9 TO -34.4 F

ACCEPTABLE ZONES

QUEBEC

ONTARIO

SASKATCHEWAN

MANITOBA

BB

CC

D

D

X

3

SEE STANDARD PLANTING DETAILS.

DEFICIENCY IMMEDIATELY. MULCH ENTIRE MASS PLANTING BED.

NOTIFY ENGINEER OF GROSS PLANT QUANTITY SURPLUS OR

THE CENTER OF THE TREE TO THE CENTER OF THE SHRUB.

AROUND EACH CONIFER TREE. RADIUS WILL BE MEASURED FROM

SHRUBS AROUND EACH DECIDUOUS TREE AND 8' CLEAR RADIUS

UNLESS SPECIFIED OTHERWISE. PROVIDE 5' RADIUS CLEAR OF

FILL IN WITH REMAINING PLANTS. USE TRIANGULAR SPACING,

IN STAGGERED ROWS ON THE PERIMETER FIRST, THEN UNIFORMLY

LESS, UNLESS OTHERWISE SPECIFIED ON SHEETS. PLANT BEDS

PREPARE MASS PLANTING BEDS FOR PLANTS PLACED AT 6' OR

LIVE BUD

BRANCH COLLAR

RIDGE

BRANCH BARK

BRANCH

DEAD

LIVE BRANCH

MN

IA

4WI

115

3

4

NO RODENT PROTECTION IS REQUIRED.

NOT TO SCALE

METAL LANDSCAPE EDGER

4" METAL EDGER

TURF GRASS AREA

PLANTING AREA

SHRUB OR PERENNIAL

PLANTING BED

Page 11: OF - mwmo.orgdate drw ckd app revision.. hoyer heights reconstruction.\ f in a lp la n \1 2 0 6 7 _ ln 0 1.d g n lp 600d2317 lp 600d4569 scj 47256 sean c. jergens of the state of minnesota.

DA

TE P

RIN

TE

D =

1/1

6/2

020

6:0

0:0

0 P

MFIL

E N

AM

E =

DATELIC. NO.

DATE:

DATE:

DATE:

DRW:

CHK:

APP:

OF

NO. DATE DRW APPCKD REVISION

HOYER HEIGHTS RECONSTRUCTION...\FinalPla

n\1

2067_ln

11.d

gn

LP 600D4569LP 600D2317

SCJ

47256

SEAN C. JERGENS

OF THE STATE OF MINNESOTA.PROFESSIONAL LANDSCAPE ARCHITECT UNDER THE LAWS SUPERVISION AND THAT I AM A DULY LICENSEDREPORT WAS PREPARED BY ME OR UNDER MY DIRECTI HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION, OR

12/18/19

1/14/2020

SCJ

RB 1/14/2020

1/14/2020

134

LANDSCAPING DETAILS

3 x

3 / 5 x HEIGHT

INSTALLATION OF PLANTS

B

A

B

A

BALLED & BURLAPPED STOCK

1.SCARIFY SIDES AND BOTTOM OF HOLE.

2.PROCEED WITH CORRECTIVE PRUNING.

WITH BURLAP AND WIRE BASKET, (IF USED), INTACT.

FLARE IS AT OR UP TO 2" ABOVE THE FINISHED GRADE

COMPACTED PLANTING SOIL. INSTALL PLANT SO THE ROOT

3.SET PLANT ON UNDISTURBED NATIVE SOIL OR THOROUGHLY

4.SLIT REMAINING TREATED BURLAP AT 6" INTERVALS.

THE ROOTBALL, THEN WATER PLANT.

5.BACKFILL TO WITHIN APPROXIMATELY 12" OF THE TOP OF

ROOTS.

REMOVE ALL TWINE. REMOVE OR CORRECT STEM GIRDLING

BURLAP AND NAILS FROM THE TOP 1/3 OF THE BALL.

HORIZONTAL RINGS WHICHEVER IS GREATER. REMOVE ALL

6.REMOVE THE TOP 1/3 OF THE BASKET OR THE TOP TWO

7.PLUMB AND BACKFILL WITH PLANTING SOIL.

AND FILL VOIDS.

8.WATER THOROUGHLY WITHIN 2 HOURS TO SETTLE PLANTS

9.BACK FILL VOIDS AND WATER A SECOND TIME.

UNLESS SOIL MOISTURE IS EXCESSIVE.

10.PLACE MULCH WITHIN 48 HOURS OF THE SECOND WATERING

1.SCARIFY SIDES AND BOTTOM OF HOLE.

2.PROCEED WITH CORRECTIVE PRUNING OF TOP AND ROOT.

REMOVE OR CORRECT STEM GIRDLING ROOTS.

TO REDIRECT AND PREVENT CIRCLING FIBROUS ROOTS.

3.REMOVE CONTAINER AND SCORE OUTSIDE OF SOIL MASS

TO 2" ABOVE THE FINISHED GRADE.

PLANT SO THE TOP OF THE ROOT FLARE IS AT OR UP

THOROUGHLY COMPACTED PLANTING SOIL. INSTALL

4.SET PLANT ON UNDISTURBED NATIVE SOIL OR

5.PLUMB AND BACKFILL WITH PLANTING SOIL.

AND FILL VOIDS.

6.WATER THOROUGHLY WITHIN 2 HOURS TO SETTLE PLANT

7.BACK FILL VOIDS AND WATER A SECOND TIME.

WATERING UNLESS SOIL MOISTURE IS EXCESSIVE.

8.PLACE MULCH WITHIN 48 HOURS OF THE SECOND

CONTAINER STOCK

FOR PLANTING SOIL

FOR MULCH DETAIL

SEE STANDARD

PLANTING DETAIL (B)

(MnDOT 2571.3F)

PLANTING HOLE DIMENSIONS

ROOT FLAIR TO BOTTOM OF SOIL BALL.

HOLE DEPTH FOR B&B AND CONTAINER PLANTS SHALL NOT EXCEED MEASUREMENT FROM

PLANT TYPEAND INCLUDING

PLANT SIZE UP TO

WIDTH

(A) MINIMUM HOLE

HOLE DEPTH

(B) APPROXIMATE

TREESORNAMENTALDECIDUOUS &

3' B.R. 46" 13"

4' B.R 46" 14"

5' B.R. 48" 14"

6' B.R. 54" 15"

7' B.R 60" 16"

8' B.R. 66" 19"

0.75" B.R. 48' 12"

1" B.R. 54" 14"

1.25" B.R. 60" 14"

1.5 B.R. 66" 15"

1.75" B.R 72" 16"

2" B.R. 84" 19"

4' B.B. 42" 11"

5' B.B. 48" 12"

6' B.B. 52" 14"

8' B.B. 66" 16"

10' B.B. 66" 16"

12' B.B. 48" 16"

1" B.B. 54" 14"

1.25" B.B. 56" 15"

1.5" B.B. 61" 15"

1.75" B.B. 66" 16"

2" B.B. 72" 16"

2.5" B.B. 84" 19"

3" B.B. 96" 20"

3.5" B.B. 114" 23"

4" B.B. 126" 25"

AND PERENNIALSSHRUBS, ROSESDECIDUOUS

12" B.R. 24" 7"

15" B.R. 28" 8"

18" B.R. 30" 8"

2' B.R. 33" 9"

3' B.R. 42" 11"

4' B.B. 48" 12"

TRENCH.

CONTINUOUS

SPACING IN A

UPON ON-CENTER

SHALL BE BASED

DEPTH AND WIDTH

PERENNIAL HOLE

5' B.R. 54" 14"

6' B.R. 60" 14"

18" B.B. 27" 7"

2' B.B. 30" 8"

3' B.B. 36" 9"

4' B.B. 42" 11"

5' B.B. 48" 12"

6' B.B. 54" 14"

MULCH PLACEMENT (MnDOT 2571.3H)

PLANTING HOLE DIMENSIONS

ROOT FLAIR TO BOTTOM OF SOIL BALL.

HOLE DEPTH FOR B&B AND CONTAINER PLANTS SHALL NOT EXCEED MEASUREMENT FROM

PLANT TYPEAND INCLUDING

PLANT SIZE UP TO

WIDTH

(A) MINIMUM HOLE

HOLE DEPTH

(B) APPROXIMATE

TREESCONIFEROUS

2' B.B 36" 10"

3' B.B 42" 11"

4' B.B 51" 13"

TERMINAL BUDS

WILL CONTAIN

CONIFER BRANCHES

AT LEAST 2/3 OF ALL

5' B.B 60" 13"

6' B.B 66" 15"

7' B.B 72" 16"

8' B.B 81" 18"

9' B.B 90" 20"

10' B.B 102" 21"

12' B.B 114" 24"

SHRUBSCONIFEROUS 18" B.B. 24" 7"

3' B.B. 48" 12"

(UPRIGHT)

SHRUBSCONIFEROUS 18" SPR B.B. 30" 8"

2' SPR B.B. 36" 9"

(SPREADING)

GROWN PLANTSCONTAINER

CELLPACKS / PLUGS 6" 2.5"

2.25" CONT. 7" 3"

3.5" CONT. 10" 3"

4" CONT. 11" 4"

4.5" CONT. 13" 4"

6"/1 QT CONT. 15" 5.5"

1# CONT. 18" 6"

2# CONT. 23" 7.5"

3# CONT. 29" 8.5"

5# CONT. 30" 11"

7# CONT. 37" 11"

15# CONT. 44" 14"

10# CONT. 45" 15"

20# CONT. 60" 16"

25# CONT. 72" 17"

SEEDLINGS

6" SEEDLING 15" 14"

9" SEEDLING 18" 14"

12" SEEDLING 23" 16"

18" SEEDLING 30" 16"

2' SEEDLING 36" 18"

VINES

1 YR. MED B.R. 15" 11"

1 YR. NO. 1 B.R. 17" 14'

2 YR. MED. B.R. 33" 12"

2 YR. NO. 1 B.R. 42" 15"

TYPE OF PLANT SQ. FT. PER PLANT

CONIFEROUS TREES 2

ORNAMENTAL TREES

DECIDUOUS AND

ORNAMENTAL GRASS

PERENNIALS,

ROSE BUSHS,

DECIDUOUS SHRUBS,

CONIFEROUS AND

SPACING x SPACING

VINES SPACING x 2

2

MULCH AREA CALCULATOR

= 3.1416

6"

MA

X

DECIDUOUS TREE (3')

TRANSPLANT (RADIUS+2')

+3 X

SPADE DIAMETER+1 X

CONIFEROUS TREE

TREES OR SHRUBS

MACHINE-MOVED

TRUNK OR MAIN STEM.

SHRUBS AT THE

FROM TREES AND

NO MORE THAN 6"

LESS THAN 3" AND

1.PULL MULCH BACK NO

MINIMUM 3" DEPTH.

MAINTAINED AT A

THE MULCH DEPTH IS

ESTABLISHED PERIOD IF

THROUGHOUT THE

IS ACCEPTABLE

DETERIORATING MULCH

2.SUBSIDING OR

MAXIMUM DEPTH.

NOT EXCEED THE 6"

MINIMUM DEPTH, DO

BELOW THE 3"

3.ADD MULCH WHEN

REPLACED.

REMOVED AND

WITH SOIL MUST BE

4.MULCH CONTAMINATED

2

2

2

SPACING FROM TRUNK

HEIG

HT

(RADIUS+3')

116

IN TREE TRENCH SEE

STORM SEWER DETAILS

5' FOR DECIDUOUS TREES

8' FOR CONF. TREES

CHART ON STANDARD PLANTING DETAILS (B)

MINIMUMS FROM THE PLANTING HOLE DIMENSIONS

HOLE EXCAVATION WIDTH IN ACCORDANCE WITH

PLANT SPACING IN MASS BEDS

PLANTING DETAIL (B)

SEE STANDARD

FOR MULCH DETAILFOR PLANTING SOIL

IN TREE TRENCH SEE

STORM SEWER DETAILS

Page 12: OF - mwmo.orgdate drw ckd app revision.. hoyer heights reconstruction.\ f in a lp la n \1 2 0 6 7 _ ln 0 1.d g n lp 600d2317 lp 600d4569 scj 47256 sean c. jergens of the state of minnesota.

DA

TE P

RIN

TE

D =

1/1

6/2

020

6:0

0:0

1 P

MFIL

E N

AM

E =

DATELIC. NO.

DATE:

DATE:

DATE:

DRW:

CHK:

APP:

OF

NO. DATE DRW APPCKD REVISION

HOYER HEIGHTS RECONSTRUCTION...\FinalPla

n\1

2067_ln

12.d

gn

LP 600D4569LP 600D2317

SCJ

47256

SEAN C. JERGENS

OF THE STATE OF MINNESOTA.PROFESSIONAL LANDSCAPE ARCHITECT UNDER THE LAWS SUPERVISION AND THAT I AM A DULY LICENSEDREPORT WAS PREPARED BY ME OR UNDER MY DIRECTI HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION, OR

12/18/19

1/14/2020

SCJ

RB 1/14/2020

1/14/2020

134

LANDSCAPING DETAILS

STAKING AND GUYING

STEEL POST SIZING

CALIPER STEEL POST TYPE A B C D

4 INCHES

LESS THEN7'-0"

MIN.

3'-0"4'-0" 3'-0"

INCHES

THEN 4

GREATER 10'-0"MIN.

4'-0" 6'-0" 5'-0"

A

B

C

D

SLOPE.

REGARDLESS OF GROUND

ROOT BALL. DRIVE PLUMB

WIRES. PLACE OUTSIDE OF

OR DRILLED TO RETAIN GUY

TEEL POSTS TO BE NOTCHED1.S

BE APPROVED.

GUYING SYSTEMS WILL NOT

RUBBER HOSE AND WIRE

2.REQUESTS TO SUBSTITUTE

4.REMOVE WITHIN ONE YEAR.

10 ga WIRE.

STRAPS. ATTACH WITH

THICK AND 1.5" WIDE

POLYETHYLENE, 40 MIL.

POLYROPYLENE OR

16" LONG

SEE CHART

STEEL POST

BY THE ENGINEER.

PROBLEM, OR AS DIRECTED

WIND CONDITIONS ARE A

WHERE VANDALISM, SOIL, OR

TREES IN A PLUMB CONDITION

OR NECESSARY TO MAINTAIN

REQUIRED UNLESS SPECIFIED

3. TREE STAKING IS NOT

OR APPROVED EQUAL.

POST (MnDOT 3401)

CHANNEL STEEL SIGN

10', 2.2 LB. FLANGED

(MnDOT 2571.3I1)

OR APPROVED EQUAL.

POST (MnDOT 3403)

ROLLED STEEL FENCE

117

PLANT SCHEDULE

2 BTU Nyssa sylvatica 2.5" CAL. B&B Single, straight leaderBLACK TUPELO

3 ELMUlmus americana 'Princeton'

2.5" CAL. B&B Single, straight leaderST. CROIX ELM

4 HBCeltis occidentalis

2.5" CAL. B&B Single, straight leaderCOMMON HACKBERRY

3 LPT acerifolia × Platanus 2.5" CAL. B&B Single, straight leaderLONDON PLANE TREE

3 RSMAcer rubrum 'Franks Red'

2.5" CAL. B&B Single, straight leaderRED SUNSET MAPLE

6 SWOQuercus bicolor

2.5" CAL. B&B Single, straight leaderSWAMP WHITE OAK

PERENNIALS SPACING

#1 CONTAINER GRASSES, SEDGES, AND FORBS

188 BABBouteloua gracilis 'Blonde Ambition'

#1 CONT 24" ON CENTERBLONDE AMBITION BUFFALO GRASS

245 BESRudbeckia 'Goldsturm'

#1 CONT 24" ON CENTERGOLDSTURM BLACK EYED SUSAN

97 BFMAsclepias tuberosa

#1 CONT 24" ON CENTERBUTTERFLY MILKWEED

220 HLBSchizachyrium scoparium 'MinnBlue A'

#1 CONT 24" ON CENTERHEAVEN LITTLE BLUESTEM

34 INGSorghastrum nutans 'Indian Steel'

#1 CONT 24" ON CENTERINDIAN STEEL' INDIAN GRASS

225 IRIIris versicolor

#1 CONT 24" ON CENTERBLUE FLAG IRIS

74 JPWEupatorium maculatum 'Phantom'

#1 CONT 24" ON CENTERPHANTOM JOE PYE WEED

142 KBSLiatris spicata 'Kobold'

#1 CONT 24" ON CENTERKOBOLD BLAZINGSTAR

228 PCFEchinacea 'Pixie Meadowbrite'

#1 CONT 24" ON CENTERPIXIE MEADOWBRITE PURPLE CONEFLOWER

730 PDSSporobolus heterolepis 'Tara'

#1 CONT 24" ON CENTERTARA' PRAIRIE DROPSEED GRASS

122 MONMonarda 'Grand Parade'

#1 CONT 24" ON CENTERGRAND PARADE' MONARDA

4" CONTAINER GRASSES, SEDGES, AND FORBS SPACING

345 BLSLiatris spicata

4" CONT 12" ON CENTERBLAZINGSTAR

387 CANAnemone canadensis

4" CONT 12" ON CENTERCANADA ANEMONE

345 CORCoreopsis lanceolata

4" CONT 12" ON CENTERLANCE-LEAVED COREOPSIS

466 FXSCarex vulpinoidea

4" CONT 12" ON CENTERFOX SEDGE

226 LLBHoustonia longifolia

4" CONT 12" ON CENTERLONG LEAF BLUET

345 PARJuncus tenuis

4" CONT 12" ON CENTERPATH RUSH

226 PPCDalea purpurea

4" CONT 12" ON CENTERPURPLE PRAIRIE CLOVER

QTY SYMBOL BOTANICAL NAME SIZE ROOT REMARKS

DECIDUOUS TREES (21)