Figure 2: Modular Energy Generator Functional Layout Objec&ve: Technical Approach: Accomplishments: Next Steps: Poten&al Impact: Y8.AP.B Implementation of a Modular Electric Generator in the Dominican Republic Landon Mackey, Greg Norris, Eric Green, Di Zhu, Taha Arif, Dr. Ewan Pritchard To design a Modular Electric Generator (“MEG”) comprised of proven US manufactured products for customer specific application that will be piloted in Punta Cana, Dominican Republic under the CEPM utility. Figure 1: MEG Pilot Location Punta Cana Site Load Demand, Solar and Wind Renewable Resource Analysis Detailed Cost and Impact Analysis, and Power System Simulation Control Development and Real-Time HIL (Hardware in Loop) Testing Control Implementation and testing of Battery Management & Chargers Component Sizing selection finalized for all critical components Financial Feasibility assessment completed for lifecycle of product MEG System Prototype Construction and full scale Performance Testing Factory Acceptance Testing (FAT) and Pilot Commissioning on Site System Level Controls Integration and External Messaging Protocols Low Voltage Continuity of Operation System Integration and Testing Improve electric grid stability and power reliability for unstable electric power systems in wide variety of energy applications around the World Provides reduction of cost, time, and difficulty of renewable energy integration through modular system design and onboard management Increase penetration of renewable energy anywhere in the world Commercially marketable, that is capable of being easily and rapidly shipped and implemented worldwide, with variable inputs and loads Electric Utility Grid AC Loads Natural Gas DC Generator Renewables Battery Energy Storage DC Loads Power Conversion Modules Hybrid Load and Grid Tie Inverter 240V AC Grid Input Figure 3: Traditional Microgrid compared to the MEG Solution Figure 5: MEG Profile on Summer Sunny (Left) and Summer Cloudy (Right) day Figure 4: Modular Energy Generators ready to Ship World-wide Internal Energy Management Interface and Connectability Battery Energy Storage – 42.9 kWh of Advanced Chemistry Battery Capacity Power Input Rectification and Battery Chargers – Modular 3 kW multi-input Units Internal Combustion Generation – 10 kW Natural Gas, rectified output DC Generation Hybrid Load and Grid Tie Inverter – 6.5 kW total AC Output to Load and Grid Battery Management and Control System – Pos-En and FREEDM Systems Center developed advanced Control Algorithm Cooling – Electronic Device, Atmospheric, and Internal Combustion Engine cooling systems integrated in MEG without external support Capacities of rectifiers, inverters, batteries, and more are scalable to customer needs Renewable Fed and Renewable Prioritizing – Receives energy from Renewable energy resources to charge energy storage, supply load, and back-feed electric grid Grid Fed – During periods without sufficient renewable energy generation – energy is pulled from the existing electric utility grid Accepts AC and DC inputs from a wide variety of resources including Wind, Solar, Hydro, and synchronous generation Natural Gas Fed – Using existing Natural Gas distribution in the Dominican Republic to supply emergency generation capability AC and DC output – Directly supplies the needs of the load without inefficient, load side converters, improving system efficiency

Transcript of Objecve - FREEDM · Objecve: Technical Approach: ... Different types of existing TFM designs. 2. 3....

Figure 2: Modular Energy Generator Functional Layout

Objec&ve:

TechnicalApproach:

Accomplishments:

NextSteps:

Poten&alImpact:

Y8.AP.B Implementation of a Modular

Electric Generator in the Dominican Republic LandonMackey,GregNorris,EricGreen,DiZhu,TahaArif,Dr.EwanPritchard

To design a Modular Electric Generator (“MEG”) comprised of proven US manufactured products for customer specific application that will be piloted in Punta Cana, Dominican Republic under the CEPM utility.

Figure 1: MEG Pilot Location

PuntaCana

•  Site Load Demand, Solar and Wind Renewable Resource Analysis •  Detailed Cost and Impact Analysis, and Power System Simulation •  Control Development and Real-Time HIL (Hardware in Loop) Testing •  Control Implementation and testing of Battery Management & Chargers •  Component Sizing selection finalized for all critical components •  Financial Feasibility assessment completed for lifecycle of product

•  MEG System Prototype Construction and full scale Performance Testing •  Factory Acceptance Testing (FAT) and Pilot Commissioning on Site •  System Level Controls Integration and External Messaging Protocols •  Low Voltage Continuity of Operation System Integration and Testing

•  Improve electric grid stability and power reliability for unstable electric power systems in wide variety of energy applications around the World

•  Provides reduction of cost, time, and difficulty of renewable energy integration through modular system design and onboard management •  Increase penetration of renewable energy anywhere in the world •  Commercially marketable, that is capable of being easily and rapidly

shipped and implemented worldwide, with variable inputs and loads

Electric Utility Grid

AC Loads

Natural Gas DC Generator

Renewables

Battery Energy Storage

DC Loads

Power Conversion

Modules

Hybrid Load and Grid Tie Inverter

240V AC Grid Input

Figure 3: Traditional Microgrid compared to the MEG Solution

Figure 5: MEG Profile on Summer Sunny (Left) and Summer Cloudy (Right) day

Figure 4: Modular Energy Generators ready to Ship World-wide

Internal Energy Management Interface and Connectability •  Battery Energy Storage – 42.9 kWh of

Advanced Chemistry Battery Capacity •  Power Input Rectification and Battery

Chargers – Modular 3 kW multi-input Units •  Internal Combustion Generation – 10 kW

Natural Gas, rectified output DC Generation •  Hybrid Load and Grid Tie Inverter – 6.5 kW

total AC Output to Load and Grid •  Battery Management and Control System –

Pos-En and FREEDM Systems Center developed advanced Control Algorithm

•  Cooling – Electronic Device, Atmospheric, and Internal Combustion Engine cooling systems integrated in MEG without external support

•  Capacities of rectifiers, inverters, batteries, and more are scalable to customer needs

• Renewable Fed and Renewable Prioritizing – Receives energy from Renewable energy resources to charge energy storage, supply load, and back-feed electric grid

• Grid Fed – During periods without sufficient renewable energy generation – energy is pulled from the existing electric utility grid

• Accepts AC and DC inputs from a wide variety of resources including Wind, Solar, Hydro, and synchronous generation

• Natural Gas Fed – Using existing Natural Gas distribution in the Dominican Republic to supply emergency generation capability

• AC and DC output – Directly supplies the needs of the load without inefficient, load side converters, improving system efficiency

Y8.AP.C Diagnostics and Prognostics for the Electric Grid Using Temporal Causal Models

Rishabh Jain, Srdjan Lukic, NC State University, NCAjay Chhokra, Abhishek Dubey, Gabor Karsai, Vanderbilt University, TN

Technical Approach:

Accomplishments:

• Diagnose relay misoperations/component failures duringfaults using the temporal event data from the protectionrelays, and prognose possible cascaded failures.

• Develop a real-time reference too to assist on-field decisionmaking for day-to-day operations, and training.

• Integrate the Reasoners using thehierarchical architecture.

• Refine prognostic techniques, designalgorithms, and evaluate performance.

• Develop TCD component models ofcommon smart grid transmission system.

• Demonstrate the functionality of thereasoner in Real time.

Temporal Causal Diagrams (TCD)Composed of1) ‘Timed Failure Propagation Graphs’ to capture the

faults in network and effects across the system2) ‘Timed Discrete Event Models’ of the system

components which arrest the propagation of fault ina network.

Hierarchical Reasoning

Next Steps:

Simulation and Diagnosis Results

E1 • Fault in Line TL5_4

E2 • Distance Relays trip and isolate the line L5_4

E3• Power redistribution• Overload in line TL3_4

E4• Distance Relay for line TL3_4 trips due to

load encroachment

E5• Power redistribution• Lines L2_4 and L6_11 experience overload.

E6• Inadequate Zone 2 settings for relays

attached to L2_4 forces a misoperation.

E7 • Blackout

Case Study – IEEE 14 Bus System

Motivation:• Utilize the protection device flags to assess the

system condition at any given time, and hypothizethe fault propagation

• Minimize human error and lack of coordination tomake grid operations more resilient.

• Coordinate between different sections of gridwithout exchanging system data

TFPG Graphs for a simple 2-source system

Use of external simulators to refine systemlevel hypothesis

• Modeling use cases for a cascadescenario for IEEE 14 Bus system, andfaults followed by relay mis-operation.

• Development of accurate Reasoners andappropriate observers to test against theabove use cases

• Successful demo presenting 1) The faultscenarios and Cascade failures withcorresponding relay operations asobserved from the system using the RealTime Digital Simulator, 2) Observing thesame scenarios from Reasoner’sperspective:

System level Reasoner was able toidentify relay misoperation, andprognose next possible failures.

Award CNS:1329803

System Hierarchy

a) Distance Relay

b) BreakerBehavior Models

Objective:

Existing Designs and Drawbacks

Design 1: Simple Structure, but idle magnets, higher leakages from idle magnets, higherend winding length.Design 2: No idle magnets, lower end winding but 3D flux path in both stator and rotor-needs soft magnetic composite (SMC) material for production (Brittle and higher reluctance).Design 3: No idle magnet, lower ending winding but 3D flux path in rotor needs SMCmaterial, stator lamination needs bending making the stacking procedure complicated.

1

Figure 1: Different types of existing TFM designs.

2 3

Proposed Design

Flux path- shown in right.2D flux path in stator makinguse of lamination possible.Features• Inner stator design- better

space utilization.• For ring winding, copper

volume and winding lengthis directly proportional toeffective radius of the ring.Inner stator gives significantadvantage in this area.

• Lower copper volume results in lower copper loss enablinghigher current density operation compared to conventionalmotor. [𝑃𝑃𝐶𝐶𝐶𝐶𝐶𝐶𝐶𝐶𝐶𝐶𝐶𝐶 = 𝐽𝐽2𝜌𝜌𝐶𝐶𝐶𝐶𝐶𝐶𝐶𝐶𝐶𝐶𝐶𝐶𝑉𝑉𝐶𝐶𝐶𝐶𝐶𝐶𝐶𝐶𝐶𝐶𝐶𝐶]

• Stator poles made of lamination steel would have samethickness throughout radial direction making lower air gap poleface area for inner stator design. This drawback is mitigated byintroducing the novel idea of overlapping stator poles.

• A term called ‘Over Span Factor’ (OSF) is introduced thatcontrols the overlapping between adjacent stator poles. LargerOSF reduces end winding length, increases pole face area andsignificantly improves torque production.

Y8.AP.D: Transverse Flux Permanent Magnet Motor for Low Speed High Torque Applications

Adeeb Ahmed, Iqbal Husain

Objective:

Technical Approach:

Accomplishments:

Next Steps:

Potential Impact:

• Designing a high torque density motor using Transverse flux topology.• Ring type winding for lower winding length and higher fill factor resulting in lower copper loss.• Focus on conventional motor manufacturing approach for practicality.

Transverse Flux Machine (TFM) Introduction• Electric machines with transverse flux path (Flux path not confined in a 2D plane).• Pros• Complex flux path enables using ring type winding resulting in shorter end winding length.• Ring winding also allows high number of pole pairs.• Torque is theoretically directly proportional to number of poles- enabling a high torque

density design.• Cons• Typically suffers high leakage flux, reducing the torque generation unless otherwise

produced in ideal case.• Higher leakage also accounts for lower power factor.• Manufacturing difficulty due to complex structure.

Vertical gap to stop leakage Coil 1

Coil 2

Figure 2: 2D flux path

(a) (b) (c) (d)Figure 3: (a) Top view with low OSF (b) 3D view for low OSF

(c) Top view with high OSF (d) 3D view for high OSF.

PerformancePeak Torque (Nm) 47.7Corner Speed (RPM) 280Max Speed (RPM) 600Minimum Ripple (%) 3.06Volume Torque Density (Nm/L) 26.8Torque per mass (Total) (Nm/kg) 5.93Torque per mass (Active) (Nm/kg) 8.93

Structural Design

Figure 5: Partial view of the stator with supporting structure

}Phase 1

}Phase 2

}Phase 3

Design ParametersOuter Diameter (mm) 135Total Axial Length (mm) 124Air gap length (mm) 1Number of Turns 15DC Bus Voltage (Volt) 60 RMS Phase Current (A) 45RMS Current Density (A/mm2) 10.4Magnet Type N42HMagnet Mass (kg) 0.605Lamination Mass (kg) 2.96Copper Mass (kg) 1Active Mass (kg) 5.35Total Mass (Including supportingstructure (kg)

8

• Complete stress analysis will be done to asses structural capability of the motor• A prototype will be built using 29 gauge (0.35 mm) M19 Steel• Suitable control algorithm will be determined to further improve the torque ripple performance• Finally, all EM performance will be compared with FEA result by testing the motor in dynamometer

• High torque density performance with no forced cooling requirement makes themotor suitable for small vehicle traction operation.

• A scaled version can be used for direct drive wind turbine application.• With necessary optimization, the design can be modified for high speed operation as

well. Outer rotor design with inner surface magnets reduces the risk for rotor failure.

Electromagnetic Performance

4

4

4

4

4

6

66 6

6

8

88

8

8

10 10 10

10

10

12

12 12

12

12

14

1414

1414

1616

16

16

1818

18

18

2020

20

2022

2222

22

6

6

6

6

6

2424

24

2426

2626

2628

2828

2830

3030

3032

3232

32

3434

34

3436 3636

3638 3838

38

8

8

8

40 4040

4042 4242 4244 4444 4446 46 46 4648

48 48 485050 50 50

10

10

1012

12

4

4

4

6

6

14

Direct Axis Current (A)

Qua

drat

ure

Axi

s C

urre

nt

-60 -50 -40 -30 -20 -10 00

10

20

30

40

50

60

5

10

15

20

25

30

35

40

45

50

50

50

505050

5050

50 52

52

525252

5252

52 54

54

545454

5454

54 56

56

565656

5656

56 58

58

585858

5858

58 60

60

606060

6060

60 62

62

626262

6262

62 64

64

646464

6464

64 66

66

666666

6666

66 68

68

686868

68

68

68 70

70

707070

70

70

70 72

72

727272

72

72

72 74

74

747474

74

74

74 76

76

767676

76

76

76 78

78

787878

78

78

78 80

80

808080

80

80

80 82

82

828282

82

82

8284

84

848484

84

84

84

86

86

8686

86

868686

8888

88

8888

8888

9090

90

9090

90

92

92

92

92

88

Speed (RPM)

Torq

ue (N

m)

Efficiency

0 100 200 300 400 500 600

5

10

15

20

25

30

35

40

45

• Finite Element Analysis was performed using Maxwell 15.0.7.• Primary objective function in the design was set as torque maximization.• Necessary tuning in magnet pole arc coefficient and stator shape was performed to limit

the torque ripple to a reasonable value.• Maximum torque per ampere (MTPA) with flux weakening control approach was

simulated for computing the efficiency plot.• Stator shape was modified to reduce stator leakage flux and increase power factor• Demagnetization test was performed considering 120˚C magnet temperature and full

rated current along d-axis. No demagnetization occurs for magnet grade N42H or higher.• Thermal FEA was performed and coil temperature was found below 180˚C in worst

condition.

(a) (b) (c) Figure 4: (a) Efficiency at 80˚C coil temperature (b) Percentage torque ripple (c) MMF inside

magnet with large demagnetization current.

Knee point for N42H at 120 ˚C

=525 kA/m

Max H=454 kA/m

Y8.AP.E Community Energy Storage System with Smart InverterHao Tu, Dr. Srdjan Lukic

Objective:

Technical Approach:

Accomplishments:

Next Steps:

Potential Impact:

Distributed Energy Storage Device (DESD) is one of the building blocks for the FREEDMsystem. This project aims at developing a 5 kW Community Energy Storage (CES) systemwith smart inverter. A smart inverter interfacing the DESD with the grid is able to switchbetween modes, set the power command, handling fault situation etc. based on only localinformation.

Power stage:With SiC MOSFET device the designed switching

frequency is 40 kHz.The battery used is SCiB battery from Toshiba which

provide a stable and superior performance.The battery voltage is boosted to grid voltage through a

boost converter. This enables a direct connection to thegrid eliminating the need of bulky transformer.

Communication system:MODBUS protocol between DSP and Beaglebone

Black(BBB),CAN protocol between Battery Management Unit(BMU)

and BBB,MQTT protocol between BBB and SST.

The power stage design has been finished. The dimension is5.5’ x 5.5’ x 7’, excluding the DC capacitor and the outputfilter.

The inverter controller with an LCL filter is designed. A innerloop PR controller is used to regulate the capacitor currentwhile the outer loop is to regulate the output current.

All communication systems have been implemented.The battery management interface has been created in

LabView.

Finishing the boost converter design,Testing the system as a whole, Implementing the phasor measurement on the DSP,Conducting Hardware in the Loop test with OPAL-RT,Designing distributed energy management algorithm running on BBB.

This project provides a standardized and sturdy solution to the DESD control. The functions implemented in the smartinverter could also be employed by other devices like Distributed Renewable Energy Resource (DRER).

Low Cost NMP-Free Lithium Electrode Synthesis Y8.AP.F

Jim P. Zheng, Pedro Moss, Eric Egwu Kalu,Annadanesh Shellikeri, Venroy Watson, Olivier Barbier

Objective:

Technical Approach:

Accomplishments:

Next Steps:

Potential Impact:

Minimizing the cost of production of LiFePO4 batteries by eliminating the use of N-Methyl-2-pyrrolidone (NMP) in the fabrication of the electrodes

Develop A DRY-METHOD for electrodes production without using NMP

Fabricate coin cells using electrodes obtain from industrial companies (MTI, CHINA).

Compare life cycles and rate of coin cells made with the different electrodes.

Optimize the method to be applicable to other battery chemistry.

Environmental friendly because no toxic solvent was used in this methodElectrode is immediately ready for cell construction ( no need for drying)Cost effective since electrodes productions is expensive in the mixing and drying stage of

the manufacturing process, 15% of manufacturing cost come from drying and solvent recovery stage.

Conduct resistivity test on the material in order to model the equivalent circuit of the propose material Conduct long term cycle analysis and rate analysis on pouch cells.

Performance Graph 0 200 400 600 800 10000

10

20

30

40

50

60

70

80

90

100

110 IH FC 108 CV FC 120 CH FC 109

Spec

ific Ca

p (mA

/g)

CYCLE # (#)

Disc electrodes for coin cell production

Effect of Temperature on the Electrochemical Performance of N-methyl Pyrrolidone (NMP)-free

LiFePO4 (LFP) Cathodes Y8.AP.GKendall Parker, Venroy Watson, Olivier Barbier, Annadanesh Shellikeri, Eric Egwu Kalu

Objective:

Technical Approach:

Accomplishments:

Next Steps:

Potential Impact:

Pursue phase 2 of NMP-free electrode fabrication method: Exploring the effect of high and low temperatures on LFP cathodes

Assemble coin cells for electrochemical characterization

Complete Electrochemical Impedance Spectroscopy (EIS) on coin cells above & below room temperature

Perform charge/discharge analysis

Concluded literature review on Lithium Ion and LFP batteries

Learned NMP-free electrode fabrication method

Manufactured LFP electrodes for coin cell assembly

Performed electrochemical tests

Develop an electrochemical model (ECM)

Assemble LiFePO4 pouch battery cells using NMP-free method

Validating performance of LFPs in extreme conditions will extend operation limits and increase stability of batteries for commercial use

Utilizing NMP-free LFP electrodes lowers production cost and decreases safety risk

Cycle #Cycle #5 10 15 20 25 30

Disc

harg

e Spe

cific

Capa

city

(mAh

/g)

Disc

harg

e Spe

cific

Capa

city

(mAh

/g)

0

20

40

60

80

100

120

140

160

38.5𝑚𝑚𝑚𝑚𝑔𝑔

77.1𝑚𝑚𝑚𝑚𝑔𝑔

154.2𝑚𝑚𝑚𝑚𝑔𝑔 168.7

𝑚𝑚𝑚𝑚𝑔𝑔

198.0𝑚𝑚𝑚𝑚𝑔𝑔

241.0𝑚𝑚𝑚𝑚𝑔𝑔

Cycles at Room Temp (~20°C)

Cycle #Cycle #5 10 15 20 25 30

Disc

harg

e Spe

cific

Capa

city

(mAh

/g)

Disc

harg

e Spe

cific

Capa

city

(mAh

/g)

0

20

40

60

80

100

120

140

160

Cycles at 60°C38.5

𝑚𝑚𝑚𝑚𝑔𝑔

77.1𝑚𝑚𝑚𝑚𝑔𝑔

154.2𝑚𝑚𝑚𝑚𝑔𝑔 168.7

𝑚𝑚𝑚𝑚𝑔𝑔

198.0𝑚𝑚𝑚𝑚𝑔𝑔

241.0𝑚𝑚𝑚𝑚𝑔𝑔

Legend

NMP Free, In House (IH)Competitor - China (CH)Conventional Wet-Chemistry (CV)Competitor - MTI Corp (MTI)

Modeling Lithium-Ion Battery Degradation Y8.AP.H

Eugene N. Moss Jr., Ruben Nelson, Mark H. Weatherspoon

Objective:

Technical Approach:

Accomplishments:

Next Steps:

Potential Impact:

To develop a virtual model of a Lithium Manganese Oxide/Lithium Titanate Oxide (LMO/LTO) battery.

To cycle battery under adverse and ambient conditions to observe capacity fade potential drop over long term cycling.

Use the Li-ion Battery module in COMSOL to create a 1D LTO/LMO Li-ion battery model. Illustrate the battery condition as it is influenced by temperature. Cycle battery to observe simulation of physical changes on battery degradation.

Costs associated with physical battery tests may be avoided while gaining a complete understanding of physical changes and battery performance.

Determine the correct parameters for the LTO battery. Observe how porosity and electrode thickness affect battery performance.

Cost Analysis Modeling for Peak Shaving of Energy Storage Devices Y8.AP.I

R. Scott, L. Morris, M.H. Weatherspoon

Objective:

Technical Approach:

Accomplishments:

Next Steps:

Potential Impact:

•Develop Cost Analysis Modeling for DESD• Optimize Battery Sizing Strategy for Peak Shaving

• Literature Review (Cost Analysis – Peak Shaving Model)• Develop Cost Analysis of the LiFePO4 Battery • Model LiFePO4 Battery in COMSOL• Define peak load shaving • List Potential Peak Shaving Models• Summarize Pros and Cons of the Top

Commercially Available Peak Shaving Models

• Reduction on the Load Demand needed to support GEH• Reduction in Cost of the ESS

• Develop COMSOL Model for the LTO-LMO Battery• Develop Peak Shaving Model • Differentiate Between the New Peak Shaving

Model and the Commercially Available Models

-200

0

200

400

600

800

1000

1200

1400

1600

1800

1 11 21 31 41 51 61 71

Pow

er (k

W)

Time (hr) - July 29 - 31, 2015

GEH Projected Load Profile

Load Consumption (kW)Peak ShavingBattery Usage (kW)Solar Power (kW)

•Completed LiteratureReview

• Development of BasisCOMSOL Lithium- IonBattery