Nutanix NX Platforms Spec Sheets · NX-1065-G7 SPECIFICATION MODEL Nutanix : Per Node ([4] per...
Transcript of Nutanix NX Platforms Spec Sheets · NX-1065-G7 SPECIFICATION MODEL Nutanix : Per Node ([4] per...
NX-1065-G7 SPECIFICATION
MODEL Nutanix : Per Node ([4] per Block) NX-1065-G7 (Configure to Order)
USE CASE(S) Remote Office/Branch Office, Test and Development
SERVERCOMPUTE**
Dual Intel Cascade Lake:
Silver 4208 [8 cores / 2.1 GHz]
Silver 4210 [10 cores / 2.2 GHz]
STORAGE CAPACITY
HYBRID (SSD-HDD) [1] x SSD: [1.92 TB or 3.84 TB], [2] x HDD: [6 TB, 8 TB, 10 TB or 12 TB]
HYBRID(SSD-HDD-SED) [1] x SSD: [1.92 TB or 3.84 TB], [2] x HDD: [6 TB or 8 TB]
MEMORY 128 GB, 192 GB, 256 GB, 384 GB, 512 GB
NETWORKCONNECTIONS
SERVERBOARD [1] x Dual-port 10GBASE-T SIOM
PCIE SLOT 1
[1] x Dual-port 10 GbE SFP+ NIC (or)
[1] x Quad-port 10 GbE SFP+ NIC (or)
[1] x Dual-port 10 GBase-T NIC
GPU N/A
CERTIFICATIONS Energy Star, CSAus, FCC, CSA, ICES, CE, KCC, RCM, VCCI-A, BSMI, EAC, SABS, INMETRO,S-MARK, UKRSEPRO, BIS
DIMENSIONS(PER BLOCK)
Height: 3.46"(88 mm)
Width: 19.04"(483.58 mm)
Depth: 30.84"(783.25 mm)
Rack Units: 2U 4N
WEIGHT(PER BLOCK)
Standalone: 92.99 lbs.(42.18 kg)
Package: 130.07 lbs.(59.0 kg)
Node: 7.05 lbs.(3.2 kg)
SYSTEM COOLING 4x 80mm heavy duty fans with PWM fan speed controls
OPERATINGENVIRONMENT(PER BLOCK)
Op Temp Rng: 50° to 95°F(10° to 35°C)
Non-Op Temp Rng: -40° to 158°F(-40° to 70°C)
MODEL Nutanix : Per Node ([4] per Block) NX-1065-G7 (Configure to Order)
Op Humidity Rng (non-condensing): 20% to 95%
Non-Op Humidity Rng: 5% to 95%
POWERCONSUMPTION
Maximum: 1519W
Typical: 968W
POWER SUPPLY(DUAL SUPPLY /BLOCK)
1.2kW Output @100-240V, 9.8-7.5A, 50-60Hz;
2.2kW Output @220-240V, 10.0-9.8A, 50-60Hz;
80PLUS TITANIUM
THERMALDISSIPATION
Maximum: 5184 BTU/hr
Typical: 3302 BTU/hr
OPERATINGREQUIREMENTS(PER BLOCK)
Input Voltage: 100-240V AC auto-range, Input Frequency: 50-60Hz
** number of cores per CPU socket.
NX-3060-G7 SPECIFICATION
MODEL Nutanix : Per Node ([4] per Block) NX-3060-G7 (Configure to Order)
USE CASE(S) Private Cloud, End-User Computing/Virtual Desktop Infrastructures
SERVERCOMPUTE**
Dual Intel Cascade Lake:
Silver 4208 [8 cores / 2.1 GHz]
Gold 5220 [18 cores / 2.2 GHz]
Gold 6230 [20 cores / 2.1 GHz]
Silver 4210 [10 cores / 2.2 GHz]
Silver 4214 [12 cores / 2.2 GHz]
Silver 4216 [16 cores / 2.1 GHz]
Gold 6226 [12 cores / 2.7 GHz]
STORAGE CAPACITY
HYBRID (SSD-HDD) [2] x SSD: [1.92 TB or 3.84 TB], [4] x HDD: [2 TB]
ALL FLASH(SSD-SED) [2, 4, 6] x SSD: [1.92 TB or 3.84 TB]
HYBRID(SSD-HDD-SED) [2] x SSD: [1.92 TB or 3.84 TB], [4] x HDD: [2 TB]
ALL FLASH (SSD) [2, 4, 6] x SSD: [1.92 TB or 3.84 TB]
HYBRID (SSD-NVME) [4] x SSD: [1.92 TB or 3.84 TB]
MEMORY 128 GB, 192 GB, 256 GB, 384 GB, 512 GB, 768 GB, 1024 GB, 1536 GB
NETWORKCONNECTIONS
SERVERBOARD [1] x Dual-port 10GBASE-T SIOM
PCIE SLOT 1
[1] x Dual-port 10 GbE SFP+ NIC (or)
[1] x Quad-port 10 GbE SFP+ NIC (or)
[1] x Dual-port 10 GBase-T NIC (or)
[1] x Dual-port 25 GbE SFP28 NIC (or)
[1] x Dual-port 40 GbE QSFP28 NIC
GPU N/A
CERTIFICATIONS Energy Star, CSAus, FCC, CSA, ICES, CE, KCC, RCM, VCCI-A, BSMI, EAC, SABS, INMETRO,S-MARK, UKRSEPRO, BIS
MODEL Nutanix : Per Node ([4] per Block) NX-3060-G7 (Configure to Order)
DIMENSIONS(PER BLOCK)
Height: 3.50"(89 mm)
Width: 17.76"(451 mm)
Depth: 30.63"(778 mm)
Rack Units: 2U 4N
WEIGHT(PER BLOCK)
Standalone: 78.00 lbs.(35.38 kg)
Package: 104.94 lbs.(47.6 kg)
Node: 7.05 lbs.(3.2 kg)
SYSTEM COOLING 4x 80mm heavy duty fans with PWM fan speed controls
OPERATINGENVIRONMENT(PER BLOCK)
Op Temp Rng: 50° to 95°F(10° to 35°C)
Non-Op Temp Rng: -40° to 158°F(-40° to 70°C)
Op Humidity Rng (non-condensing): 20% to 95%
Non-Op Humidity Rng: 5% to 95%
POWERCONSUMPTION
Maximum: 2118W
Typical: 1800W
POWER SUPPLY(DUAL SUPPLY /BLOCK)
1.2kW Output @100-240V, 9.8-7.5A, 50-60Hz;
2.2kW Output @220-240V, 10.0-9.8A, 50-60Hz;
80PLUS TITANIUM
THERMALDISSIPATION
Maximum: 7098 BTU/hr
Typical: 5800 BTU/hr
OPERATINGREQUIREMENTS(PER BLOCK)
Input Voltage: 100-240V AC auto-range, Input Frequency: 50-60Hz
** number of cores per CPU socket.
NX-8035-G7 SPECIFICATION
MODEL Nutanix : Per Node ([2] per Block) NX-8035-G7 (Configure to Order)
USE CASE(S) Database and Business Critical Apps
SERVERCOMPUTE**
Dual Intel Cascade Lake:
Silver 4208 [8 cores / 2.1 GHz]
Gold 6234 [8 cores / 3.3 GHz]
Gold 5220 [18 cores / 2.2 GHz]
Gold 6242 [16 cores / 2.8 GHz]
Gold 6252 [24 cores / 2.1 GHz]
Gold 6240 [18 cores / 2.6 GHz]
Silver 4214 [12 cores / 2.2 GHz]
Silver 4216 [16 cores / 2.1 GHz]
Gold 6248 [20 cores / 2.5 GHz]
STORAGE CAPACITY
HYBRID (SSD-HDD) [2] x SSD: [1.92 TB or 3.84 TB], [4] x HDD: [6 TB, 8 TB, 10 TB or 12 TB]
ALL FLASH(SSD-SED) [2, 4, 6] x SSD: [1.92 TB or 3.84 TB]
HYBRID(SSD-HDD-SED) [2] x SSD: [1.92 TB or 3.84 TB], [4] x HDD: [6 TB or 8 TB]
ALL FLASH (SSD) [2, 4, 6] x SSD: [1.92 TB or 3.84 TB]
HYBRID (SSD-NVME) [4] x SSD: [1.92 TB or 3.84 TB]
MEMORY 128 GB, 192 GB, 256 GB, 384 GB, 512 GB, 768 GB, 1024 GB, 1536 GB
NETWORKCONNECTIONS
SERVERBOARD [1] x Dual-port 10GBASE-T SIOM
PCIE SLOT 1
[1] x Dual-port 10 GbE SFP+ NIC (or)
[1] x Quad-port 10 GbE SFP+ NIC (or)
[1] x Dual-port 10 GBase-T NIC (or)
[1] x Dual-port 25 GbE SFP+ NIC (or)
[1] x Dual-port 40 GbE SFP+ NIC
GPU N/A
MODEL Nutanix : Per Node ([2] per Block) NX-8035-G7 (Configure to Order)
CERTIFICATIONS Energy Star, CSAus, FCC, CSA, ICES, CE, KCC, RCM, VCCI-A, BSMI, EAC, SABS, INMETRO,S-MARK, UKRSEPRO, BIS
DIMENSIONS(PER BLOCK)
Height: 3.50"(89 mm)
Width: 19.06"(484 mm)
Depth: 31.54"(801 mm)
Rack Units: 2U 2N
WEIGHT(PER BLOCK)
Standalone: 70.55 lbs.(32.0 kg)
Package: 100.71 lbs.(45.68 kg)
SYSTEM COOLING 4x 80mm heavy duty fans with PWM fan speed controls
OPERATINGENVIRONMENT(PER BLOCK)
Op Temp Rng: 50° to 95°F(10° to 35°C)
Non-Op Temp Rng: -40° to 158°F(-40° to 70°C)
Op Humidity Rng (non-condensing): 20% to 95%
Non-Op Humidity Rng: 5% to 95%
POWERCONSUMPTION
Maximum: 1331W
Typical: 861W
POWER SUPPLY(DUAL SUPPLY /BLOCK)
1.2kW Output @100-240V, 9.8-7.5A, 50-60Hz;
2.2kW Output @220-240V, 10.0-9.8A, 50-60Hz;
80PLUS TITANIUM
THERMALDISSIPATION
Maximum: 4548 BTU/hr
Typical: 2928 BTU/hr
OPERATINGREQUIREMENTS(PER BLOCK)
Input Voltage: 100-240V AC auto-range, Input Frequency: 50-60Hz
** number of cores per CPU socket.
NX-8155-G7 SPECIFICATION
MODEL Nutanix : Per Node ([1] per Block) NX-8155-G7 (Configure to Order)
USE CASE(S) Database and Business Critical Apps
SERVERCOMPUTE**
Dual Intel Cascade Lake:
Gold 6244 [8 cores / 3.6 GHz]
Gold 6254 [18 cores / 3.1 GHz]
Gold 5220 [18 cores / 2.2 GHz]
Gold 6242 [16 cores / 2.8 GHz]
Platinum 8280 [28 cores / 2.7 GHz]
Platinum 8268 [24 cores / 2.9 GHz]
Gold 6248 [20 cores / 2.5 GHz]
STORAGE CAPACITY
HYBRID (SSD-HDD) [2, 4] x SSD: [1.92 TB or 3.84 TB], [8, 10] x HDD: [6 TB or 8 TB]
ALL FLASH(SSD-SED) [4, 6, 8, 10, 12] x SSD: [1.92 TB or 3.84 TB]
HYBRID(SSD-HDD-SED) [2, 4] x SSD: [1.92 TB or 3.84 TB], [8, 10] x HDD: [6 TB or 8 TB]
ALL FLASH (SSD) [4, 6, 8, 10, 12] x SSD: [1.92 TB or 3.84 TB]
HYBRID (SSD-NVME) [4, 6, 8] x SSD: [1.92 TB or 3.84 TB]
MEMORY 128 GB, 192 GB, 256 GB, 384 GB, 512 GB, 768 GB, 1024 GB, 1536 GB
NETWORKCONNECTIONS
SERVERBOARD[2] x 10 GBase-T ports (Port 1 is IPMI failover) (or)
[1] x 10/100/1000 GBASE-T (IPMI port)
PCIE SLOT 1, 2, 3
[1] x Dual-port 10 GbE SFP+ NIC (or)
[1] x Quad-port 10 GbE SFP+ NIC (or)
[1] x Dual-port 10 GBASE-T NIC (or)
[1] x Dual-port 25 GbE SFP+ NIC (or)
[1] x Dual-port 40 GbE SFP+ NIC
GPU N/A
MODEL Nutanix : Per Node ([1] per Block) NX-8155-G7 (Configure to Order)
CERTIFICATIONS Energy Star, CSAus, FCC, CSA, ICES, CE, KCC, RCM, VCCI-A, BSMI, EAC, SABS, INMETRO,S-MARK, UKRSEPRO, BIS
DIMENSIONS(PER BLOCK)
Height: 3.50"(89 mm)
Width: 17.20"(437 mm)
Depth: 28.46"(723 mm)
Rack Units: 2U 1N
WEIGHT(PER BLOCK)
Standalone: 72.09 lbs.(32.7 kg)
Package: 66.45 lbs.(30.14 kg)
SYSTEM COOLING 4x 80mm heavy duty fans with PWM fan speed controls
OPERATINGENVIRONMENT(PER BLOCK)
Op Temp Rng: 50° to 95°F(10° to 35°C)
Non-Op Temp Rng: -40° to 158°F(-40° to 70°C)
Op Humidity Rng (non-condensing): 20% to 95%
Non-Op Humidity Rng: 5% to 95%
POWERCONSUMPTION
Maximum: 1070W
Typical: 700W
POWER SUPPLY(DUAL SUPPLY /BLOCK)
1.6kW Output @100-240V, 13.0-8.0A, 50-60Hz;
80PLUS TITANIUM
THERMALDISSIPATION
Maximum: 3650 BTU/hr
Typical: 2388 BTU/hr
OPERATINGREQUIREMENTS(PER BLOCK)
Input Voltage: 100-240V AC auto-range, Input Frequency: 50-60Hz
** number of cores per CPU socket.
NX-1065-G6 SPECIFICATION
MODEL Nutanix : Per Node ([4] per Block) NX-1065-G6 (Configure to Order)
USE CASE(S) Remote Office/Branch Office, Test and Development
SERVERCOMPUTE**
Dual Intel Skylake:
Silver 4108 [8 cores / 1.8 GHz]
Silver 4114 [10 cores / 2.2 GHz]
STORAGE CAPACITY
HYBRID (SSD-HDD) [1] x SSD: [960 GB or 1.92 TB], [2] x HDD: [2 TB, 4 TB, 6 TB, 8 TB or 12 TB]
HYBRID(SSD-HDD-SED) [1] x SSD: [960 GB or 1.92 TB], [4] x HDD: [2 TB, 4 TB, 6 TB, 8 TB or 12 TB]
MEMORY 128 GB, 192 GB, 256 GB, 384 GB, 512 GB
NETWORKCONNECTIONS
SERVERBOARD [1] x Dual-port 10GBASE-T SIOM
PCIE SLOT 1
[1] x Dual-port 10 GbE SFP+ NIC (or)
[1] x Quad-port 10 GbE SFP+ NIC (or)
[1] x Dual-port 10 GBase-T NIC (or)
[1] x Dual-port 25 GbE SFP28 NIC
GPU N/A
CERTIFICATIONS Energy Star, CSAus, FCC, CSA, ICES, CE, KCC, RCM, VCCI-A, BSMI, EAC, SABS, INMETRO,S-MARK, UKRSEPRO, BIS
DIMENSIONS(PER BLOCK)
Height: 3.50"(89 mm)
Width: 17.76"(451 mm)
Depth: 30.63"(778 mm)
Rack Units: 2U 4N
WEIGHT(PER BLOCK)
Standalone: 78.00 lbs.(35.38 kg)
Package: 104.94 lbs.(47.6 kg)
Node: 7.05 lbs.(3.2 kg)
SYSTEM COOLING 4x 80mm heavy duty fans with PWM fan speed controls
OPERATING Op Temp Rng: 50° to 95°F(10° to 35°C)
MODEL Nutanix : Per Node ([4] per Block) NX-1065-G6 (Configure to Order)
ENVIRONMENT(PER BLOCK)
Non-Op Temp Rng: -40° to 158°F(-40° to 70°C)
Op Humidity Rng (non-condensing): 20% to 95%
Non-Op Humidity Rng: 5% to 95%
POWERCONSUMPTION
Maximum: 1519W
Typical: 968W
POWER SUPPLY(DUAL SUPPLY /BLOCK)
1.2kW Output @100-240V, 9.8-7.5A, 50-60Hz;
2.2kW Output @220-240V, 10.0-9.8A, 50-60Hz;
80PLUS TITANIUM
THERMALDISSIPATION
Maximum: 5184 BTU/hr
Typical: 3302 BTU/hr
OPERATINGREQUIREMENTS(PER BLOCK)
Input Voltage: 100-240V AC auto-range, Input Frequency: 50-60Hz
** number of cores per CPU socket.
NX-1175S-G6 SPECIFICATION
MODEL Nutanix : Per Node ([1] per Block) NX-1175S-G6 (Configure to Order)
USE CASE(S) Remote Office/Branch Office
SERVERCOMPUTE**
Single Intel Skylake:
Silver 4108 [8 cores / 1.8 GHz]
Gold 6140 [18 cores / 2.3 GHz]
Silver 4116 [12 cores / 2.1 GHz]
STORAGE CAPACITY
HYBRID (SSD-HDD) [2] x SSD: [480 GB, 960 GB, 1.92 TB or 3.84 TB], [2] x HDD: [2 TB, 4 TB, 6 TB, 8 TB or 12 TB]
HYBRID(SSD-HDD-SED) [2] x SSD: [960 GB or 1.92 TB], [2] x HDD: [4 TB, 6 TB, 8 TB or 12 TB]
ALL FLASH (SSD) [2, 4] x SSD: [960 GB or 1.92 TB]
MEMORY 64 GB, 96 GB, 128 GB, 192 GB, 256 GB, 384 GB
NETWORKCONNECTIONS
PCIE SLOT 1
[1] x Dual-port 10 GbE SFP+ NIC (or)
[1] x Quad-port 10 GbE SFP+ NIC (or)
[1] x Dual-port 10 GBase-T NIC (or)
[1] x Dual-port 1GbE RJ45 NIC
GPU N/A
CERTIFICATIONS Energy Star, CSAus, FCC, CSA, ICES, CE, KCC, RCM, VCCI-A, BSMI, EAC, SABS, INMETRO,S-MARK, UKRSEPRO, BIS
DIMENSIONS(PER BLOCK)
Height: 1.69"(43 mm)
Width: 19.06"(484 mm)
Depth: 29.61"(752 mm)
Rack Units: 1U 1N
WEIGHT(PER BLOCK)
Standalone: 31.11 lbs.(14.11 kg)
Package: 46.30 lbs.(21.0 kg)
SYSTEM COOLING 5x 40mm heavy duty fans with PWM fan speed controls
OPERATING Op Temp Rng: 50° to 95°F(10° to 35°C)
MODEL Nutanix : Per Node ([1] per Block) NX-1175S-G6 (Configure to Order)
ENVIRONMENT(PER BLOCK)
Non-Op Temp Rng: -40° to 158°F(-40° to 70°C)
Op Humidity Rng (non-condensing): 20% to 95%
Non-Op Humidity Rng: 5% to 95%
POWERCONSUMPTION
Maximum: 334W
Typical: 217W
POWER SUPPLY(DUAL SUPPLY /BLOCK)
500W Output @100-240V, 6.1-2.6A, 50-60Hz;
80PLUS TITANIUM
THERMALDISSIPATION
Maximum: 1140 BTU/hr
Typical: 741 BTU/hr
OPERATINGREQUIREMENTS(PER BLOCK)
Input Voltage: 100-240V AC auto-range, Input Frequency: 50-60Hz
** number of cores per CPU socket.
NX-3060-G6 SPECIFICATION
MODEL Nutanix : Per Node ([4] per Block) NX-3060-G6 (Configure to Order)
USE CASE(S) Private Cloud, End-User Computing/Virtual Desktop Infrastructures
SERVERCOMPUTE**
Dual Intel Skylake:
Silver 4108 [8 cores / 1.8 GHz]
Gold 6126 [12 cores / 2.6 GHz]
Gold 5120 [14 cores / 2.2 GHz]
Gold 6130 [16 cores / 2.1 GHz]
Silver 4114 [10 cores / 2.2 GHz]
Silver 4116 [12 cores / 2.1 GHz]
Gold 6138 [20 cores / 2.0 GHz]
STORAGE CAPACITY
HYBRID (SSD-HDD) [2] x SSD: [960 GB or 1.92 TB], [4] x HDD: [2 TB]
ALL FLASH(SSD-SED) [2, 4, 6] x SSD: [960 GB or 1.92 TB]
HYBRID(SSD-HDD-SED) [2] x SSD: [960 GB or 1.92 TB], [4] x HDD: [2 TB]
ALL FLASH (SSD) [2, 4, 6] x SSD: [960 GB, 1.92 TB or 3.84 TB]
HYBRID (SSD-NVME) [4] x SSD: [960 GB, 1.92 TB or 3.84 TB]
MEMORY 192 GB, 256 GB, 384 GB, 512 GB, 768 GB
NETWORKCONNECTIONS
SERVERBOARD [1] x Dual-port 10GBASE-T SIOM
PCIE SLOT 1
[1] x Dual-port 10 GbE SFP+ NIC (or)
[1] x Quad-port 10 GbE SFP+ NIC (or)
[1] x Dual-port 10 GBase-T NIC (or)
[1] x Dual-port 25 GbE SFP28 NIC
GPU N/A
CERTIFICATIONS Energy Star, CSAus, FCC, CSA, ICES, CE, KCC, RCM, VCCI-A, BSMI, EAC, SABS, INMETRO,S-MARK, UKRSEPRO, BIS
MODEL Nutanix : Per Node ([4] per Block) NX-3060-G6 (Configure to Order)
DIMENSIONS(PER BLOCK)
Height: 3.50"(89 mm)
Width: 17.76"(451 mm)
Depth: 30.63"(778 mm)
Rack Units: 2U 4N
WEIGHT(PER BLOCK)
Standalone: 78.00 lbs.(35.38 kg)
Package: 104.94 lbs.(47.6 kg)
Node: 7.05 lbs.(3.2 kg)
SYSTEM COOLING 4x 80mm heavy duty fans with PWM fan speed controls
OPERATINGENVIRONMENT(PER BLOCK)
Op Temp Rng: 50° to 95°F(10° to 35°C)
Non-Op Temp Rng: -40° to 158°F(-40° to 70°C)
Op Humidity Rng (non-condensing): 20% to 95%
Non-Op Humidity Rng: 5% to 95%
POWERCONSUMPTION
Maximum: 2080W
Typical: 1700W
POWER SUPPLY(DUAL SUPPLY /BLOCK)
1.2kW Output @100-240V, 9.8-7.5A, 50-60Hz;
2.2kW Output @220-240V, 10.0-9.8A, 50-60Hz;
80PLUS TITANIUM
THERMALDISSIPATION
Maximum: 7098 BTU/hr
Typical: 5800 BTU/hr
OPERATINGREQUIREMENTS(PER BLOCK)
Input Voltage: 100-240V AC auto-range, Input Frequency: 50-60Hz
** number of cores per CPU socket.
NX-3155G-G6 SPECIFICATION
MODEL Nutanix : Per Node ([1] per Block) NX-3155G-G6 (Configure to Order)
USE CASE(S) End-User Computing/Virtual Desktop Infrastructures
SERVERCOMPUTE**
Dual Intel Skylake:
Gold 6148 [20 cores / 2.4 GHz]
Platinum 8176 [28 cores / 2.1 GHz]
Gold 6134 [8 cores / 3.2 GHz]
Gold 5120 [14 cores / 2.2 GHz]
Gold 6130 [16 cores / 2.1 GHz]
Gold 6152 [22 cores / 2.1 GHz]
Silver 4116 [12 cores / 2.1 GHz]
STORAGE CAPACITY
HYBRID (SSD-HDD) [2] x SSD: [960 GB, 1.92 TB or 3.84 TB], [4] x HDD: [6 TB, 8 TB or 12 TB]
ALL FLASH(SSD-SED) [2, 4, 6] x SSD: [960 GB or 1.92 TB]
HYBRID(SSD-HDD-SED) [2] x SSD: [960 GB or 1.92 TB], [4] x HDD: [6 TB, 8 TB or 12 TB]
ALL FLASH (SSD) [2, 4, 6] x SSD: [960 GB, 1.92 TB or 3.84 TB]
MEMORY 192 GB, 256 GB, 384 GB, 512 GB, 768 GB, 1024 GB, 1536 GB
NETWORKCONNECTIONS
SERVERBOARD [1] x 10 GbE BASE-T RJ45
PCIE SLOT 1
[1] x Dual-port 10 GbE SFP+ NIC (or)
[1] x Quad-port 10 GbE SFP+ NIC (or)
[1] x Dual-port 10 GBase-T NIC (or)
[1] x Dual-port 25 GbE SFP28 NIC (or)
[1] x Dual-port 40 GbE QSFP28 NIC
GPU†
[0, 1, 2] x NVIDIA Tesla M10
[0, 1, 2] x NVIDIA Tesla P40
[0, 1, 2] x NVIDIA Tesla V100
CERTIFICATIONS Energy Star, CSAus, FCC, CSA, ICES, CE, KCC, RCM, VCCI-A, BSMI, EAC, SABS, INMETRO,
MODEL Nutanix : Per Node ([1] per Block) NX-3155G-G6 (Configure to Order)
S-MARK, UKRSEPRO, BIS
DIMENSIONS(PER BLOCK)
Height: 3.50"(89 mm)
Width: 17.20"(437 mm)
Depth: 28.50"(724 mm)
Rack Units: 2U 1N
WEIGHT(PER BLOCK)
Standalone: 36.16 lbs.(16.4 kg)
Package: 72.09 lbs.(32.7 kg)
SYSTEM COOLING 4x 80mm heavy duty fans with PWM fan speed controls
OPERATINGENVIRONMENT(PER BLOCK)
Op Temp Rng: 50° to 86°F(10° to 30°C)
Non-Op Temp Rng: -40° to 158°F(-40° to 70°C)
Op Humidity Rng (non-condensing): 20% to 95%
Non-Op Humidity Rng: 5% to 95%
POWERCONSUMPTION
Maximum: 1400W
Typical: 980W
POWER SUPPLY(DUAL SUPPLY /BLOCK)
1.6kW Output @100-240V, 13.0-8.0A, 50-60Hz;
80PLUS TITANIUM
THERMALDISSIPATION
Maximum: 4777 BTU/hr
Typical: 3344 BTU/hr
OPERATINGREQUIREMENTS(PER BLOCK)
Input Voltage: 100-240V AC auto-range, Input Frequency: 50-60Hz
** number of cores per CPU socket.
† number of cores per CPU socket. Gold 6144, Gold 6154, Platinum 8180 cannot be used in-conjunction with GPUs.
NX-3170-G6 SPECIFICATION
MODEL Nutanix : Per Node ([1] per Block) NX-3170-G6 (Configure to Order)
USE CASE(S) Private Cloud, End-User Computing/Virtual Desktop Infrastructures
SERVERCOMPUTE**
Dual Intel Skylake:
Gold 6148 [20 cores / 2.4 GHz]
Platinum 8176 [28 cores / 2.1 GHz]
Gold 5120 [14 cores / 2.2 GHz]
Gold 6144 [8 cores / 3.5 GHz]
Gold 6154 [18 cores / 3.0 GHz]
Gold 6152 [22 cores / 2.1 GHz]
Platinum 8180 [28 cores / 2.5 GHz]
Gold 6128 [6 cores / 3.4 GHz]
STORAGE CAPACITY
HYBRID (SSD-HDD) [2] x SSD: [960 GB, 1.92 TB or 3.84 TB], [6] x HDD: [2 TB]
ALL FLASH(SSD-SED) [2, 4, 6] x SSD: [960 GB or 1.92 TB]
HYBRID(SSD-HDD-SED) [2] x SSD: [960 GB or 1.92 TB], [6] x HDD: [2 TB]
ALL FLASH (SSD) [2, 4, 6, 8] x SSD: [960 GB, 1.92 TB or 3.84 TB]
HYBRID (SSD-NVME) [8] x SSD: [960 GB, 1.92 TB or 3.84 TB]
MEMORY 192 GB, 256 GB, 384 GB, 512 GB, 768 GB, 1024 GB, 1536 GB
NETWORKCONNECTIONS
SERVERBOARD [1] x 10G BASE-T RJ45
PCIE SLOT 1
[1] x Dual-port 10 GbE SFP+ NIC (or)
[1] x Quad-port 10 GbE SFP+ NIC (or)
[1] x Dual-port 10 GBase-T NIC (or)
[1] x Dual-port 25 GbE SFP28 NIC (or)
[1] x Dual-port 40 GbE QSFP28 NIC
GPU†[0, 1] x NVIDIA Tesla M10
[0, 1] x NVIDIA Tesla P40
MODEL Nutanix : Per Node ([1] per Block) NX-3170-G6 (Configure to Order)
CERTIFICATIONS Energy Star, CSAus, FCC, CSA, ICES, CE, KCC, RCM, VCCI-A, BSMI, EAC, SABS, INMETRO,S-MARK, UKRSEPRO, BIS
DIMENSIONS(PER BLOCK)
Height: 1.69"(43 mm)
Width: 17.20"(437 mm)
Depth: 28.50"(724 mm)
Rack Units: 1U 1N
WEIGHT(PER BLOCK)
Standalone: 26.01 lbs.(11.8 kg)
Package: 39.00 lbs.(17.69 kg)
SYSTEM COOLING 8x 40mm heavy duty fans with PWM fan speed controls
OPERATINGENVIRONMENT(PER BLOCK)
Op Temp Rng: 50° to 86°F(10° to 30°C)
Non-Op Temp Rng: -40° to 158°F(-40° to 70°C)
Op Humidity Rng (non-condensing): 20% to 95%
Non-Op Humidity Rng: 5% to 95%
POWERCONSUMPTION
Maximum: 1053W
Typical: 700W
POWER SUPPLY(DUAL SUPPLY /BLOCK)
1.2kW Output @100-240V, 9.8-7.5A, 50-60Hz;
80PLUS TITANIUM
THERMALDISSIPATION
Maximum: 3650 BTU/hr
Typical: 2388 BTU/hr
OPERATINGREQUIREMENTS(PER BLOCK)
Input Voltage: 100-240V AC auto-range, Input Frequency: 50-60Hz
** number of cores per CPU socket.
† number of cores per CPU socket. Gold 6144, Gold 6154, Platinum 8180 cannot be used in-conjunction with GPUs.
NX-5155-G6 SPECIFICATION
MODEL Nutanix : Per Node ([1] per Block) NX-5155-G6 (Configure to Order)
USE CASE(S) Analytics and Big Data, Backup and Disaster Recovery, Files and Objects
SERVERCOMPUTE**
Dual Intel Skylake:
Silver 4108 [8 cores / 1.8 GHz]
STORAGE CAPACITY
HYBRID (SSD-HDD) [2, 4] x SSD: [960 GB, 1.92 TB or 3.84 TB], [8, 10] x HDD: [4 TB, 6 TB or 8 TB]
ALL FLASH(SSD-SED) [4, 6, 8, 10, 12] x SSD: [960 GB or 1.92 TB]
HYBRID(SSD-HDD-SED) [2, 4] x SSD: [960 GB or 1.92 TB], [8, 10] x HDD: [6 TB or 8 TB]
ALL FLASH (SSD) [4, 6, 8, 10, 12] x SSD: [960 GB, 1.92 TB or 3.84 TB]
HYBRID (SSD-NVME) [4, 6, 8] x SSD: [1.92 TB or 3.84 TB]
MEMORY 128 GB, 192 GB
NETWORKCONNECTIONS
SERVERBOARD[2] x 10 GBase-T ports (Port 1 is IPMI failover) (or)
[1] x 10/100/1000 GBASE-T (IPMI port)
PCIE SLOT 1, 2, 3
[1] x Dual-port 10 GbE SFP+ NIC (or)
[1] x Quad-port 10 GbE SFP+ NIC (or)
[1] x Dual-port 10 GBASE-T NIC (or)
[1] x Dual-port 25 GbE SFP28 NIC (or)
[1] x Dual-port 40 GbE QSFP28 NIC
GPU N/A
CERTIFICATIONS Energy Star, CSAus, FCC, CSA, ICES, CE, KCC, RCM, VCCI-A, BSMI, EAC, SABS, INMETRO,S-MARK, UKRSEPRO, BIS
DIMENSIONS(PER BLOCK)
Height: 3.50"(89 mm)
Width: 17.20"(437 mm)
Depth: 28.46"(723 mm)
Rack Units: 2U 1N
MODEL Nutanix : Per Node ([1] per Block) NX-5155-G6 (Configure to Order)
WEIGHT(PER BLOCK)
Standalone: 72.09 lbs.(32.7 kg)
Package: 66.45 lbs.(30.14 kg)
SYSTEM COOLING 4x 80mm heavy duty fans with PWM fan speed controls
OPERATINGENVIRONMENT(PER BLOCK)
Op Temp Rng: 50° to 95°F(10° to 35°C)
Non-Op Temp Rng: -40° to 158°F(-40° to 70°C)
Op Humidity Rng (non-condensing): 20% to 95%
Non-Op Humidity Rng: 5% to 95%
POWERCONSUMPTION
Maximum: 806W
Typical: 550W
POWER SUPPLY(DUAL SUPPLY /BLOCK)
1.6kW Output @100-240V, 13.0-8.0A, 50-60Hz;
80PLUS TITANIUM
THERMALDISSIPATION
Maximum: 2750 BTU/hr
Typical: 1860 BTU/hr
OPERATINGREQUIREMENTS(PER BLOCK)
Input Voltage: 100-240V AC auto-range, Input Frequency: 50-60Hz
** number of cores per CPU socket.
NX-8035-G6 SPECIFICATION
MODEL Nutanix : Per Node ([2] per Block) NX-8035-G6 (Configure to Order)
USE CASE(S) Database and Business Critical Apps
SERVERCOMPUTE**
Dual Intel Skylake:
Silver 4108 [8 cores / 1.8 GHz]
Gold 6148 [20 cores / 2.4 GHz]
Gold 6134 [8 cores / 3.2 GHz]
Gold 5120 [14 cores / 2.2 GHz]
Gold 6152 [22 cores / 2.1 GHz]
Gold 6140 [18 cores / 2.3 GHz]
Silver 4114 [10 cores / 2.2 GHz]
Silver 4116 [12 cores / 2.1 GHz]
Bronze 3106 [8 cores / 1.7 GHz]
Gold 6128 [6 cores / 3.4 GHz]
STORAGE CAPACITY
HYBRID (SSD-HDD) [2] x SSD: [960 GB or 1.92 TB], [4] x HDD: [6 TB, 8 TB or 12 TB]
ALL FLASH(SSD-SED) [2, 4, 6] x SSD: [960 GB or 1.92 TB]
HYBRID(SSD-HDD-SED) [2] x SSD: [960 GB or 1.92 TB], [4] x HDD: [6 TB, 8 TB or 12 TB]
ALL FLASH (SSD) [2, 4, 6] x SSD: [960 GB, 1.92 TB or 3.84 TB]
HYBRID (SSD-NVME) [4] x SSD: [960 GB, 1.92 TB or 3.84 TB]
MEMORY 96 GB, 192 GB, 256 GB, 384 GB, 512 GB, 768 GB
NETWORKCONNECTIONS
SERVERBOARD [1] x Dual-port 10GBASE-T SIOM
PCIE SLOT 1
[1] x Dual-port 10 GbE SFP+ NIC (or)
[1] x Quad-port 10 GbE SFP+ NIC (or)
[1] x Dual-port 10 GBase-T NIC (or)
[1] x Dual-port 25 GbE SFP28 NIC
GPU N/A
MODEL Nutanix : Per Node ([2] per Block) NX-8035-G6 (Configure to Order)
CERTIFICATIONS Energy Star, CSAus, FCC, CSA, ICES, CE, KCC, RCM, VCCI-A, BSMI, EAC, SABS, INMETRO,S-MARK, UKRSEPRO, BIS
DIMENSIONS(PER BLOCK)
Height: 3.50"(89 mm)
Width: 19.06"(484 mm)
Depth: 31.54"(801 mm)
Rack Units: 2U 2N
WEIGHT(PER BLOCK)
Standalone: 70.55 lbs.(32.0 kg)
Package: 100.71 lbs.(45.68 kg)
SYSTEM COOLING 4x 80mm heavy duty fans with PWM fan speed controls
OPERATINGENVIRONMENT(PER BLOCK)
Op Temp Rng: 50° to 95°F(10° to 35°C)
Non-Op Temp Rng: -40° to 158°F(-40° to 70°C)
Op Humidity Rng (non-condensing): 20% to 95%
Non-Op Humidity Rng: 5% to 95%
POWERCONSUMPTION
Maximum: 1443W
Typical: 938W
POWER SUPPLY(DUAL SUPPLY /BLOCK)
1.2kW Output @100-240V, 9.8-7.5A, 50-60Hz;
2.2kW Output @220-240V, 10.0-9.8A, 50-60Hz;
80PLUS TITANIUM
THERMALDISSIPATION
Maximum: 4925 BTU/hr
Typical: 3202 BTU/hr
OPERATINGREQUIREMENTS(PER BLOCK)
Input Voltage: 100-240V AC auto-range, Input Frequency: 50-60Hz
** number of cores per CPU socket.
NX-8155-G6 SPECIFICATION
MODEL Nutanix : Per Node ([1] per Block) NX-8155-G6 (Configure to Order)
USE CASE(S) Database and Business Critical Apps
SERVERCOMPUTE**
Dual Intel Skylake:
Silver 4108 [8 cores / 1.8 GHz]
Gold 6148 [20 cores / 2.4 GHz]
Gold 5120 [14 cores / 2.2 GHz]
Gold 6154 [18 cores / 3.0 GHz]
Gold 6152 [22 cores / 2.1 GHz]
Platinum 8180 [28 cores / 2.5 GHz]
Silver 4114 [10 cores / 2.2 GHz]
Gold 6128 [6 cores / 3.4 GHz]
STORAGE CAPACITY
HYBRID (SSD-HDD) [2, 4] x SSD: [960 GB, 1.92 TB or 3.84 TB], [8, 10] x HDD: [4 TB, 6 TB or 8 TB]
ALL FLASH(SSD-SED) [4, 6, 8, 10, 12] x SSD: [960 GB or 1.92 TB]
HYBRID(SSD-HDD-SED) [2, 4] x SSD: [960 GB or 1.92 TB], [8, 10] x HDD: [6 TB or 8 TB]
ALL FLASH (SSD) [4, 6, 8, 10, 12] x SSD: [960 GB, 1.92 TB, 3.84 TB or 7.68 TB]
HYBRID (SSD-NVME) [4, 6, 8] x SSD: [1.92 TB or 3.84 TB]
MEMORY 192 GB, 256 GB, 384 GB, 512 GB, 768 GB, 1024 GB, 1536 GB
NETWORKCONNECTIONS
SERVERBOARD[2] x 10 GBase-T ports (Port 1 is IPMI failover) (or)
[1] x 10/100/1000 GBASE-T (IPMI port)
PCIE SLOT 1, 2, 3
[1] x Dual-port 10 GbE SFP+ NIC (or)
[1] x Quad-port 10 GbE SFP+ NIC (or)
[1] x Dual-port 10 GBASE-T NIC (or)
[1] x Dual-port 25 GbE SFP28 NIC (or)
[1] x Dual-port 40 GbE QSFP28 NIC
GPU N/A
MODEL Nutanix : Per Node ([1] per Block) NX-8155-G6 (Configure to Order)
CERTIFICATIONS Energy Star, CSAus, FCC, CSA, ICES, CE, KCC, RCM, VCCI-A, BSMI, EAC, SABS, INMETRO,S-MARK, UKRSEPRO, BIS
DIMENSIONS(PER BLOCK)
Height: 3.50"(89 mm)
Width: 17.20"(437 mm)
Depth: 28.46"(723 mm)
Rack Units: 2U 1N
WEIGHT(PER BLOCK)
Standalone: 72.09 lbs.(32.7 kg)
Package: 66.45 lbs.(30.14 kg)
SYSTEM COOLING 4x 80mm heavy duty fans with PWM fan speed controls
OPERATINGENVIRONMENT(PER BLOCK)
Op Temp Rng: 50° to 95°F(10° to 35°C)
Non-Op Temp Rng: -40° to 158°F(-40° to 70°C)
Op Humidity Rng (non-condensing): 20% to 95%
Non-Op Humidity Rng: 5% to 95%
POWERCONSUMPTION
Maximum: 1070W
Typical: 700W
POWER SUPPLY(DUAL SUPPLY /BLOCK)
1.6kW Output @100-240V, 13.0-8.0A, 50-60Hz;
80PLUS TITANIUM
THERMALDISSIPATION
Maximum: 3650 BTU/hr
Typical: 2388 BTU/hr
OPERATINGREQUIREMENTS(PER BLOCK)
Input Voltage: 100-240V AC auto-range, Input Frequency: 50-60Hz
** number of cores per CPU socket.