Nuaire Thermal DuctingNuaire Thermal Ducting Description of Product . This is an assessment of the...
Embed Size (px)
Transcript of Nuaire Thermal DuctingNuaire Thermal Ducting Description of Product . This is an assessment of the...

Photo/isometric drawing
provided by manufacturer
Nuaire Thermal Ducting
Description of Product
This is an assessment of the Nuaire insulated
ducting system for a mechanical ventilation
system with heat recovery. Nuaire’s new range
of thermal duct is specifically designed to
comply with 2010 Building Regulations to
significantly improve thermal conductivity and
thermal resistance of ventilation ducting used
in domestic properties and with its unique
quick fix clip system can significantly reduce
the amount of time required to install a
compliant insulated ductwork system.
Key Factors Assessed
Safety in case of Fire
Health, Hygiene and Environmental
Safety in Use
Energy Economy and heat retention
Validity
This certificate was first issued on 25th April 2014 and is valid until 25th April 2018.
Issue Dated 22nd May 2015
Certificate No: EWW415

Ducting should be insulated where it passes through unheated areas and voids (e.g. loft spaces) with equivalent of at least
25mm of a material having a thermal conductivity of ≤0.04W/(m.K) to reduce the possibility of condensation forming. Where a
duct extends above roof level the section above the roof should be insulated or a condensate trap should be fitted just below
roof level.
The Ducting only has been assessed and will be used in conjunction with an appropriate mechanical ventilation system.
The ducting is satisfactory both in pressure loss and thermal conductance and should only be used in accordance with the
limitations identified below.
Approved document Part B Vol I 2006 Fire safety: section 2.6 and sequence
BS 9991:2011 Fire safety in the design, management and use of residential buildings: clause 32.2
Approved document Part F 2010 Ventilation: section 43.4-4.36, and table 5.2d
The length of pipework is to be designed on an individual basis for each property type for both NTD 204 and NTD 125 systems
Intumescent grills to be fitted at each penetration in fire floors
Not for use if penetrating fire walls
This duct is only suitable for use in a fully designed mechanical ventilation systems
Use rigid duct for the majority of your installation
Should not be installed where it can be crushed
A non-hardening acrylic sealant and aluminium duct tape should be used to connect ductwork.
Nuaire’s CONTRAP should be used with the ductwork to prevent backflow of moisture going to the fan unit.

LABC consider that, Nuaire Thermal Ducting, will meet the functional requirements of the Building
Regulations (listed below) if the criteria detailed in this certificate are met;
The Building Regulations 2010 (as amended) England & Wales
Regulation 7 Materials and workmanship
Note: The products are acceptable.
AD B Fire Safety
Note: Subject to limitations detailed below in Conditions section.
AD F Ventilation
Note: Subject to limitations detailed below in Conditions section.
AD L1B Conservation of fuel and power
Note: The thermal insulation performance of this system should be considered in the
context of the contribution made to the overall performance of the roof structure.
The Building Regulations 2010 (as amended) England
AD L1A Conservation of fuel and power
Note: The thermal insulation performance of this system should be considered in the
context of the contribution made to the overall performance of the roof structure.
The Building Regulations 2010 (as amended) Wales
AD L1A Conservation of fuel and power
Note: The thermal insulation performance of this system should be considered in the
context of the contribution made to the overall performance of the roof structure.
The Building (Scotland) Regulations 2004 (as amended)
If you would like to discuss a specific use of the product in Scotland it will require an additional
assessment under the Scottish Building Regulations and accordingly you should contact the
LABSS STAS Administrator at www.labss.org

LABC Warranty
This product confirms to the Functional Requirements of the LABC Warranty Technical Manual.
Heating and ventilation contractors association DW/143 ductwork leakage testing
Heating and ventilation contractors association DW/154 specifications for plastic ductwork
BS EN 12667:2001 Thermal performance
BS EN 13501-1:2002 Fire classifications for construction products and building elements
Domestic ventilation compliance guide
BRE test report 293579
BRE test report 293578
Nuaire Ductmaster brochure Environmental product declaration
Neopor brochure raw materials
Neopor Innovation in insulation
Nuaire thermal ducting
Certificate of conformity
Thermal report 1
Thermal report 2
NHBC Standards 2014 Chapter 3.2 `Mechanical ventilation with heat recovery'
LABC Warranty Technical Manual Chapter 9.4 Heating & mechanical services

Nuaire Ltd
Western Industrial Estate
Caerphilly
CF83 1NA
Tel: 029 2085 800
Email: [email protected]
Web: www.nuaire.co.uk

RD Certificate Number: EWW415 Nuaire Thermal Ducting
Description
This is an assessment of the Nuaire insulated ducting system for a mechanical
ventilation system with heat recovery. Nuaire’s new range of thermal duct is
specifically designed to comply with 2010 Building Regulations to significantly
improve thermal conductivity and thermal resistance of ventilation ducting used
in domestic properties and with its unique quick fix clip system can significantly
reduce the amount of time required to install a compliant insulated ductwork
system.
Scope of Registration
Due to space limitations, the Registered Detail certificate should be consulted
for the full scope of this registration.
Validity
This system has been checked for compliance in accordance with English and Welsh Building Regulations.
LABC Warranty also accepts its use when installed and used in accordance with and in relation to LABC Warranty’s current
Technical Standards.
Registration was first issued on 25/04/14 and is valid until 25/04/18 providing there are no amendments to applicable
regulations.
Issue dated 22/05/2015
Further Information
For more detailed information including access to the full certificate and supporting documents please use this link
http://www.labc.co.uk/our-services/registered-details/eww415-nuaire-thermal-duct
Nuaire Ltd
Western Industrial Estate
Caerphilly
CF83 1NA
Tel: 029 2085 800
Email: [email protected]