NSH-5509_User_Manual.pdf
-
Upload
diamondtahir2004 -
Category
Documents
-
view
3 -
download
1
Transcript of NSH-5509_User_Manual.pdf
-
Managed 8-port 10/100 Mbps
plus 1-port 100-FX Access Switch
NSH-5509
User Manual
(December 2007)
-
VOLKTEK NSH-5509 MANAGED 8-PORT 10/100 + 1-PORT 100-FX SWITCH
COPYRIGHT All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, whether electronic, mechanical, photo copying, recording or otherwise, without the prior written permission of the publisher. FCC WARNING This equipment has been tested and found to comply with the limits for a class A device, pursuant to part 15 of FCC rules. These limits are designed to provide reasonable protection against harmful interference in a commercial installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communication. Operation of this equipment in a residential area is likely to cause harmful interference, in which case, the user will be required to correct the interference at the users own expense.
CE This is a Class A product. In a domestic environment, this product may cause radio interference in which case the user may be required to take adequate measures. Take special care to read and understand all the content in the warning boxes:
Warning
1
-
VOLKTEK NSH-5509 MANAGED 8-PORT 10/100 + 1-PORT 100-FX SWITCH
2
TABLE OF CONTENTS
1 ABOUT THIS GUIDE..........................................................................5 1.1 Welcome............................................................................................................5 1.2 Purpose .............................................................................................................5 1.3 Terms/Usage .....................................................................................................5 1.4 Features.............................................................................................................5 1.5 Specifications ...................................................................................................6 1.6 Package Contents.............................................................................................7
2 HARDWARE DESCRIPTION .............................................................8 2.1 Product Illustration...........................................................................................8 2.2 Connectors........................................................................................................9
2.2.1 10/100Base-TX Ports .........................................................................................................9 2.2.2 100Base-FX Port ................................................................................................................9
3 INSTALLATION................................................................................10 3.1 Desktop installation........................................................................................10 3.2 Mounting on a rack.........................................................................................10 3.3 Getting Connected..........................................................................................10 3.4 Powering On the Unit .....................................................................................11 3.5 Connecting Fiber Cable..................................................................................11 3.6 Connecting Copper Cable..............................................................................11 3.7 Connecting the Console Port Cable..............................................................11 3.8 Connecting to computers or a LAN ..............................................................12 3.9 Attaching the power adapter .........................................................................12
4 LED INDICATORS ...........................................................................13
5 ENHANCED FEATURES .................................................................14 5.1 Xpress Ring.....................................................................................................14
6 CONFIGURATION............................................................................15 6.1 Overview of configuration options................................................................15 6.2 External SNMP-based network management application ...........................15
7 MANAGEMENT VIA CONSOLE PORT ...........................................16 7.1 Connecting a HyperTerminal .........................................................................16
8 MANAGEMENT VIA INTERNET BROWSER INTERFACE.............19
-
VOLKTEK NSH-5509 MANAGED 8-PORT 10/100 + 1-PORT 100-FX SWITCH
3
8.1 Overview..........................................................................................................19 8.2 System Details ................................................................................................19
8.2.1 Homepage (System Details / System Info)....................................................................20 8.2.2 Board Info .........................................................................................................................21 8.2.3 DHCP Configuration ........................................................................................................22
8.3 Configuration ..................................................................................................22 8.3.1 Port Configuration ...........................................................................................................23 8.3.2 Port Status........................................................................................................................24 8.3.3 Ethernet Loop Detection.................................................................................................24
8.4 Bridge Menu ....................................................................................................25 8.4.1 Bridge Configuration (Enable / Disable RSTP, etc.).....................................................25 8.4.2 RSTP System Configuration...........................................................................................26 8.4.3 RSTP Per-Port Configuration .........................................................................................26 8.4.4 Xpress Ring Configuration .............................................................................................27
8.5 VLAN Menu......................................................................................................28 8.5.1 VLAN Type (VLAN Configuration)..................................................................................29 8.5.2 VLAN Configuration (Port-based) ..................................................................................29 8.5.3 Tag-based VLAN Port Configuration (Port Info)...........................................................30 8.5.4 Tag-based Info (VLAN Table) .........................................................................................31 8.5.5 Management VLAN ..........................................................................................................32
8.6 Rate Control ....................................................................................................33 8.7 Port Mirroring..................................................................................................34 8.8 Trunk Configuration .......................................................................................34
8.8.1 Aggregator Setting ..........................................................................................................34 8.8.2 LACP Configuration ........................................................................................................35 8.8.3 LACP Link Status.............................................................................................................35
8.9 IGMP Menu ......................................................................................................36 8.9.1 IGMP Configuration .........................................................................................................36 8.9.2 IGMP Groups Status........................................................................................................37
8.10 MAC Menu .....................................................................................................37 8.10.1 MAC Table Status ..........................................................................................................37 8.10.2 Lock Learning MAC .......................................................................................................37 8.10.3 Static MAC Configuration .............................................................................................38 8.10.4 MAC Limit Configuration ..............................................................................................39
8.11 QoS Menu......................................................................................................39 8.11.1 Base Configuration........................................................................................................39 8.11.2 Tag Priority .....................................................................................................................40 8.11.3 IP ToS Priority ................................................................................................................41
8.12 Management Configuration .........................................................................41 8.12.1 Serial Port Configuration ..............................................................................................41
8.13 SNMP Configuration.....................................................................................42 8.13.1 SNMP Communities.......................................................................................................42 8.13.2 IP Trap Manager.............................................................................................................42
8.14 E-mail Alarm Configuration .........................................................................43 8.15 User Configuration .......................................................................................44 8.16 Cable Test......................................................................................................44 8.17 Host Denial of Service..................................................................................45 8.18 Port Abnormal Traffic Detection..................................................................45 8.19 Firmware Download (Upgrade System) ......................................................46 8.20 Configuration File (System Backup) ...........................................................47 8.21 System Restart Menu Restart Option.......................................................48 8.22 System Parameter Settings .........................................................................48
-
VOLKTEK NSH-5509 MANAGED 8-PORT 10/100 + 1-PORT 100-FX SWITCH
4
9 COMMAND LINE INTERFACE ........................................................49 9.1 Log in...............................................................................................................49 9.2 Show commands ............................................................................................49 9.3 System configurations ...................................................................................50
9.3.1 Port configurations..........................................................................................................50 9.3.2 Spanning Tree Protocol (STP) configurations..............................................................51 9.3.3 Virtual LAN configurations .............................................................................................51 9.3.4 SNMP configurations ......................................................................................................52
10 TROUBLESHOOTING .....................................................................53
11 APPENDIX A ....................................................................................54 11.1 RJ-45 Cables .................................................................................................54 11.2 Console Cable (RJ-45 to DB-9) ....................................................................54 11.3 SNMP Trap List .............................................................................................55
12 APPENDIX B ....................................................................................56 12.1 Command Mode Summary...........................................................................56 12.2 Command Summary: User Mode (read privilege)......................................56 12.3 Command Summary: Enable Mode (read/write privilege).........................56 12.4 Command Summary: Configuration Mode (read/write privilege) .............58 12.5 Command Summary: Interface Mode (read/write privilege)......................61 12.6 Command Summary: VLAN (802.1q) Mode (read/write privilege) ............63
13 CONTACT INFORMATION ..............................................................64
-
VOLKTEK NSH-5509 MANAGED 8-PORT 10/100 + 1-PORT 100-FX SWITCH
1 About This Guide
1.1 Welcome
Congratulations on choosing the NSH-5509 Managed 8-port 10/100Base-TX + 1-port 100-FX Access Switch. This device integrates 100Mbps Fast Ethernet and 10Mbps Ethernet switching technologies with versatile management capabilities in a highly flexible package. The device provides various management interfaces including Web, serial Console, Telnet, and Command Line (CLI).
1.2 Purpose
This guide discusses how to install and configure your Managed Access Switch.
1.3 Terms/Usage
In this guide, the term Switch (first letter upper case) refers to the NSH-5509 Switch, and switch (first letter lower case) refers to other switches.
1.4 Features
Eight (8) 10/100Base-TX, one (1) 100Base-FX, and one (1) Console port (RJ-45) SNMP management application software (HP Open View and IBM/Tivoli NetView
capable) lnet Http/Web browser user interface, CLI interface via console and te
Xpress Ring (redundant ring) with less than 50ms recovery time per Ethernet ports
2km for multi-mode and up to 120km for long-haul single-
nant Unit and Multiple Dwelling Unit for example
Port-based MAC limitation to restrict the number of MAC addresses learned on each port improves network security
Auto-negotiation NWay on cop Remote & local management Extends fiber distances to
mode fiber WDM Single fiber optics Status LEDs for quick and easy network activity monitoring
Firmware upgradeable Console Port (RJ-45) for out-of-band device management. Configure the device
through a Terminal Emulator /TELNET Program RJ-45 Ethernet Ports support auto MDI/MDI-X
Fiber Port: connect various fiber optic cables (multi-mode, single-mode, long-haul single-mode, and WDM) to the fiber port VLAN port isolation function to isolate downlink ports of a VLAN group, making theSwitch suitable as a remote access switch for cases where the operator needs to service an MTU/MDU (Multiple Tean apartment building)
5
-
VOLKTEK NSH-5509 MANAGED 8-PORT 10/100 + 1-PORT 100-FX SWITCH
FCC Class A & CE approved 1.5 Specification
Standards: rnet) ast Ethernet)
ontrol runking
IEEE 802.1q VLAN es
onnectors: 8 x RJ-45 (10/100Mbps)
gement via Console Port (RJ-45) ent via RJ-45 and fiber ports
ypes: Fiber: Multi-mode (62.5/125 micron)
Max. Distanc s opper
meters (multi-mode) 1 (single mode)
10Mbps ps
s
IEEE 802.3 (10BASE-T EtheIEEE 802.3u (100BASE-TX FIEEE 802.3x Flow CIEEE 802.3ad Port TIEEE 802.1d STP IEEE 802.1w RSTP
IEEE 802.1p Priority Queu
C 1 x 100Base-FX (SC/ST) 1 x RJ-45 (Console Port) Management: Out-of-band mana In-band managem Cable T UTP: (Cat 5/5e.) Single-mode (9/125 micron)
e : C : 100 meters (Category 5/5e.) Fiber: 2,000 Up to 20,000 meters
Data Rates: Ethernet Fast Ethernet 100Mb Physical Characteristics Power: Power Input: 100~240V AC
-48VDC
Environment:
80%, non-condensing
ensing
+12VDC
Operating: Temperature: 0C to 50C Relative Humidity: 10% to
Non-Operating / Storage:
Temperature: -20C to 80C Relative Humidity: 5% to 90%, non-cond
6
-
VOLKTEK NSH-5509 MANAGED 8-PORT 10/100 + 1-PORT 100-FX SWITCH
Emissions: FCC Part 15 of Class A & CE approved
Dimensio Dimensionsns: 128 x 268 x 44 mm (D x W x H)
The a
J45 to DB9)
pads
One AC power cord (optional adapter) User Manual CD
Safety: EN 60950
Weight: 1200g
1.6 Package Contents
p ckage should include the following:
One Managed Access Switch One console port cable (R Protective caps for unused ports Four self-adhesive
7
-
VOLKTEK NSH-5509 MANAGED 8-PORT 10/100 + 1-PORT 100-FX SWITCH
2 are Description
The Switch was specially developed with a host of features that makes it particularly suited for SOHO applications that demand the utmost in reliability. The Switch was developed with Xpress Ring features. Xpress Ring offers recovery time of less than 50ms in case of network-link failure. This makes the Switch particularly suited for applications that require super-fast recovery times and maintenance of service, ensures "always-on" connectivity, eliminating costly network downtime. Being SNMP-ready, the Switch enables network managers to remotely monitor the entire networks status quickly and easily via a network port, or a console port (out-of-band) connection. The Switch is designed with 'plug-n-play' features for hassle-free integration into today's managed mixed-cabling network configurations, minimizing your troubleshooting time. Featuring Auto MDI/MDI-X detection for direct connectionnetwork managers no longer need to worry about the castraight through) when establishing connections between The Switch has auto-negotiation capabilities that allow it tleading NWay switches.
2.1 Product Illustration
Front view of Switch:
Unit LEDs Fiber port
Rear view of Switch:
Reset Button G
8 to a workstationble configuration RJ-45 ports.
o support conne
Copper Ports
Prounding Screw Hardw, switch or hub, (cross-over or
ction with
Console Port
ower Socket
-
VOLKTEK NSH-5509 MANAGED 8-PORT 10/100 + 1-PORT 100-FX SWITCH
2.2 Connectors
The Switch utilizes ports with copper and fiber port connectors functioning under Ethernet/Fast Ethernet standards.
2.2.1 10/100Base-TX Ports
The 10/100BASE-TX ports support network speeds of either 10Mbps or 100Mbps, and can operate in half- and full-duplex transfer modes. These ports also offer automatic MDI/MDI-X crossover detection that delivers true plug-n-play capability just plug the network cables into the ports and the ports will adjust according to the end-node devices. The following cabling is recommended for the RJ-45 connectors: (1)10Mbps Cat 3 or better; (2)100Mbps Cat 5 or better.
2.2.2 100Base-FX Port
The 100Base-FX port adds a fiber Fast Ethernet link to your network device. Compliant with IEEE 802.3u, this port can transmit data at 100Mbps in full-duplex mode across distances of up to 2km (with multi-mode) and up to 120km (with single-mode fiber-optic cable). The fiber ports have a choice of 2 fiber connector types: ST and SC.
9
-
VOLKTEK NSH-5509 MANAGED 8-PORT 10/100 + 1-PORT 100-FX SWITCH
3 Installation
The location chosen for installing the Switch may greatly affect its performance. When selecting a site, we recommend considering the following rules:
Install the Switch in an appropriate place. See Technical Specifications for the acceptable temperature and humidity ranges.
Install the Switch in a location that is not affected by strong electromagnetic field generators (such as motors), vibration, dust, and direct sunlight.
Leave at least 10cm of space at the front and rear of the unit for ventilation. Affix the provided rubber pads to the bottom of the Switch to protect the case
from scratching.
3.1 Desktop installation
Follow the instructions listed below to install the Switch in a desktop location.
1. Locate the Switch in a clean, flat and safe position that has convenient access to AC power.
2. Separate the four (4) self-adhesive rubber pads and attach them to the underside of the Switch.
3. Apply AC power to the Switch. (The green PWR LED on the front panel should light up).
4. Connect cables from the network partner devices to the ports on the front panel. (The green LNK LED on the front panel associated with the port should light).
This Switch can also be mounted on a vertical surface. Simply use the underside of the unit as a template to measure and mark out the position of the holes on to the surface where the unit is to be installed. Then use the two screws provided to mount the Switch firmly in place.
Warning: Because invisible laser radiation may be emitted from the aperture of the port when no cable is connected, avoid exposure to laser radiation and do not stare into open apertures.
3.2 Mounting on a rack
Attach brackets to each side of the switch and place the brackets in the racks slots. Insert and tighten two screws to securely attach the bracket to the rack on each side.
3.3 Getting Connected
The Switch is capable of connecting up to 9 network devices employing a combination of twisted-pair and fiber cabling paths at Ethernet or Fast Ethernet speeds.
10
-
VOLKTEK NSH-5509 MANAGED 8-PORT 10/100 + 1-PORT 100-FX SWITCH
3.4 Powering On the Unit
The Switch uses an AC 100~240V or DC power supply of 9~32V DC. The power and redundant power connection is provided via a terminal block located at the top of the Switch. The Switchs power supply automatically self-adjusts to the local power source and may be powered on without having any or all LAN segment cables connected. Check the front-panel LEDs as the device is powered on to verify that the Power
LED is lit. If not, check that the power cable is correctly and securely plugged in.
3.5 Connecting Fiber Cable
When connecting a fiber cable to the 100BASE-FX port on the Switch, be sure the correct type of connector (ST or SC) is used. Follow the steps below to properly connect fiber cabling:
1. Remove and keep the fiber ports (ST/SC) rubber covers. When not connected to a fiber cable, the rubber cover should be replaced to protect the fiber optics.
2. Check that the fiber terminators are clean. You can clean the cable plugs by
wiping them gently with a clean tissue or cotton ball moistened with a little ethanol. Dirty fiber terminators on fiber optic cables will impair the quality of the light transmitted through the cable and lead to degraded performance on the port.
3. Connect one end of the cable to the ST/SC port on the Switch and the other
end to the fiber port of the other device.
Note: When inserting the cable, be sure the tab on the plug clicks into position to ensure that it is properly seated.
Check the corresponding port LED on the Switch to be sure that the connection is valid. (Refer to the LED chart).
3.6 Connecting Copper Cable
The 10/100Base-T RJ-45 Ethernet ports fully support auto-sensing and auto-negotiation.
1. Insert one end of a Category 3/4/5/5e (see recommendation above) type twisted-pair cable into an available RJ-45 port on the Switch and the other end into the port of the network node.
2. Check the corresponding port LED on the Switch to ensure that the connection is
valid. (Refer to LED chart)
3.7 Connecting the Console Port Cable
The console port (DB-9) provides the out-of-band management facility.
1 Use null modem cable to connect the console port on the Switch and the other end into the COM port of the computer.
11
-
VOLKTEK NSH-5509 MANAGED 8-PORT 10/100 + 1-PORT 100-FX SWITCH
2 Insert the RJ-45 side of the (8-pin RJ-45 to DB-9) cable into the RJ-45
console port on the Switch and the other end into the COM port of the computer.
3 Configure the Hyper Terminal settings as mentioned in chapter 7.
For console port (8 pin RJ-45) pin assignment, please see Appendix A.
3.8 Connecting to computers or a LAN
You can use Ethernet cables to connect computers directly to the Switch ports. You can also connect hubs/switches to the switch ports by Ethernet cables. You can use either crossover or straight-through Ethernet cables to connect computers, hubs, or switches.
3.9 Attaching the power adapter
Connect the AC power cord to the POWER receptacle on the back of the Switch and plug the other end of the power cord into a wall outlet or a power strip. Check the front LED indicators with the description in the next chapter. If the LEDs light up as described, the Switchs hardware is working properly.
12
-
VOLKTEK NSH-5509 MANAGED 8-PORT 10/100 + 1-PORT 100-FX SWITCH
4 LED Indicators
This Switch is equipped with Unit LEDs to enable you to determine the status of the Switch, as well as Port LEDs to display what is happening in all your connections. They are as follows:
Unit LEDs
LED Condition Status On (Green) Switch uses primary power PWR
Off Primary power off or failure
Flashing (Green)
Indicating POST function upon start-up POST
On POST function successfully performed
On (Green) Port operating at 100Mbps 100 (1st to 8th Copper Ports and 9th Fiber Port)
Off Port operating at below 100Mbps
On (Green) Illuminated when the port is connected with compliant device
Flashing (Green)
Data traffic passing through port
LNK/ACT (1st to 8th Copper Ports and 9th Fiber Port)
Off No valid link established on port
NOTE 1: The fiber module does not support half-duplex mode.
13
-
VOLKTEK NSH-5509 MANAGED 8-PORT 10/100 + 1-PORT 100-FX SWITCH
5 Enhanced Features
5.1 Xpress Ring
Xpress Ring is a VOLKTEK proprietary ring protocol that enables networks to recover from link failure within 50ms. To enable Xpress Ring, it needs some network configuration: the user must assign two ring ports for each Switch in the ring. The user must also assign the Arbiter Switch which will decide if it is necessary to activate the backup path. For Xpress Ring, any switch can be the arbiter just remember that the Arbiter Switch must be part of the ring. Apart from rerouting the transmission within 50ms, the Arbiter Switch will also issue an alarm when a link failure occurs. The user will then be informed of the failure and will be able to fix the problem and reconfigure if required. Xpress Ring is the fastest ring recovery technology and is ideal for networks where the ring topology is not changed very often. For configuration of Xpress Rings, please refer to the appropriate chapter in this manual.
14
-
VOLKTEK NSH-5509 MANAGED 8-PORT 10/100 + 1-PORT 100-FX SWITCH
6 Configuration
6.1 Overview of configuration options
For advanced management capabilities, the onboard management agent provides CLI interface configuration programs. These programs can be accessed by a direct or modem connection to the console port on the front panel (out-of-band), or by a Telnet connection over the network (in-band).
The management agent is based on SNMP (Simple Network Management Protocol). This SNMP agent permits the switch to be managed from any PC in the network by using in-band management software.
The management agent also includes an embedded HTTP Web agent. This Web agent can be accessed using a standard Web browser from any computer attached to the network.
The switch gives you the flexibility to access and manage it by using any or all of the methods described. The administration console and web browser interfaces are embedded in the Switch software and can be used immediately after setup.
6.2 External SNMP-based network management application
Advantages
Communicates with Switch functions at the MIB level Based on open standards The two methods for configuring the Switch management agent are explained in the following chapters.
The first method Command Line Interface (CLI) via the Console Port to initially set IP parameters.
The second is the use of an Internet Browser Interface to configure the Switch.
15
-
VOLKTEK NSH-5509 MANAGED 8-PORT 10/100 + 1-PORT 100-FX SWITCH
7 Management via Console Port
Out-of-Band Connection Prior to accessing the switchs onboard agent via a network connection, you must first configure it with a valid IP address, subnet mask, and default gateway using an out-of-band connection or the BOOTP protocol.
After configuring the switchs IP parameters, you can access the onboard configuration program from anywhere within the attached network or via the internet. The onboard configuration program can be accessed using Telnet from any computer attached to the network. It can also be managed from any computer using a Web browser (Internet Explorer 4.0 or above, or Netscape Navigator 4.0 or above).
Access the Switch via a terminal emulator (such as Hyper Terminal) attached to the console port. The console port is set at the factory with the following default COM port properties. Configure your own terminal to match the following:
Baud rate: 38,400
Data size: 8bits
Parity: None
Stop bits: 1
Flow Control: None Note: Ensure that the terminal or PC you are using to make this connection is configured to match the above settings. Otherwise the connection will not work.
A console port cable is provided with the Switch to connect the PCs COM port with the switchs serial console (RJ-45) port. Please see Appendix A for cable pin assignment details.
7.1 Connecting a HyperTerminal
Prior to following the instructions listed below for HyperTerminal, verify that a console cable (RJ45 to DB9) connection between the Switch and work station exists. Then follow the steps below:
1. Launch the terminal emulation program on the remote workstation and power on
the Switch. Be sure to select the correct COM port.
16
-
VOLKTEK NSH-5509 MANAGED 8-PORT 10/100 + 1-PORT 100-FX SWITCH
2. Enter the correct parameters according to the defaults given above.
1. The following screen will appear on your monitor. VOLKTEK Corporation System version: 1.00.00 (built at Dec 3 2007 10:10:58) Username:
2. The default log-in name is admin with no preset password.
The system provides CLI user interface via console or telnet. After you log into the system, the default privilege level is read only, displayed with the > prompt.
Username: admin Password: NSH-5509>
3. Type enable and press Enter to turn on read/write privileged command
mode. NSH-5509> enable NSH-5509#
After log-in, type the following command to change the devices IP address, Network Mask and Gateway Address:
NSH-5509# config terminal NSH-5509(config)# ip xxx.xxx.xxx.xxx NSH-5509(config)# netmask xxx.xxx.xxx.xxx NSH-5509(config)# gateway xxx.xxx.xxx.xxx
17
-
VOLKTEK NSH-5509 MANAGED 8-PORT 10/100 + 1-PORT 100-FX SWITCH
The xxxs represent values between 0 and 255 and the user should enter their own IP address in this form. The configuration program will not accept anything outside this format. Remember to separate each part of the address with a period (dot). For example:
NSH-5509# config terminal NSH-5509(config)# ip 192.168.99.222 NSH-5509(config)# netmask 255.255.255.0 NSH-5509(config)# gateway 192.168.99.1
4. These system parameters are invalid until you save configuration with write
memory command. After you enter write memory command, the system will auto restart immediately.
NSH-5509(config)# exit NSH-5509# write memory It takes a few moments to write memory... NSH-5509# write memory $$$ Restart system....!!!
After the system restarts completely, you can type in show ip command to verify system settings. NSH-5509# show ip [eth0] Network Configuration: MAC Address : 00:0B:04:09:03:07 DHCP Client: Disabled IP Address: 192.168.99.222 Netmask : 255.255.255.0 Gateway : 192.168.99.1
When the address has been changed, please make a note of the new address, and keep it in a safe place. With HyperTerminal, the command lines are the same as that for telnet. Note: IP addresses are unique. If an address isnt available, please contact the appropriate authorities to apply for one.
18
-
VOLKTEK NSH-5509 MANAGED 8-PORT 10/100 + 1-PORT 100-FX SWITCH
8 Management via Internet Browser Interface
8.1 Overview
This section gives a step-by-step guide to configuring the Switchs management functions. A series of screen shots and instructions illustrate the main menu structure and how it works. Firstly, open a web browser and key in the Switchs IP address then press Enter. A Web Manager page like this will pop up on your screen:
Log in
The default username is: admin There is no preset password for this device, so click on OK to proceed.
8.2 System Details
When your Web browser connects with the Switchs Web agent, the home page is displayed as shown below. The home page displays the Main Menu on the left side of the screen and System Information as the main page. The Main Menu links are used to navigate to other menus and display configuration parameters and statistics.
19
-
VOLKTEK NSH-5509 MANAGED 8-PORT 10/100 + 1-PORT 100-FX SWITCH
8.2.1 Homepage (System Details / System Info)
Click on each parameter field to modify the specific settings, click Undo to restore previously saved configurations or click Apply to implement newly entered information. If you change the settings of IP Address, Subnet Mask, and Gateway on System information page, and click Apply to implement settings. The system will notify you to save these settings with a pop-on dialog box.
To save this configuration to flash memory, click Saving Settings on the bottom of Main Menu, it will link to saving page, then click the Save" button.
**Note: If you change the settings of IP Address, Subnet Mask, and Gateway on the System information page, or DHCP setting on DHCP configuration page, you must save these parameters in order for them to come into effect after you click
20
-
VOLKTEK NSH-5509 MANAGED 8-PORT 10/100 + 1-PORT 100-FX SWITCH
the Apply button. The system will auto restart after you click Save button on the Save Settings page. Other parameters on any page will come into effect immediately after you click Apply button, but will not be saved to flash memory until you go to the Save Settings page and click the Save button. In this case, the system will not restart. The system information is described below: Parameter Description Description Object ID Up Time System Name
Provides description of the Switch ID or Serial number Provides information on up time, or the time that the system has been operating Modifies the name of the Switch
Contact Location DHCP Client IP Address Subnet Mask Gateway
Enter a contact name Enter the location of Switch Disabled or clients name Default: 192.168.0.254 Default: 255.255.255.0 Default: 192.168.0.1
Note: The above are factory defaults used as an example only. A new address is important. Choose numbers between 0 and 254 in each sub-address field. Make a note of them and keep the details in a safe place. In writing this manual we used IP address 192.168.0.201 and Subnet Mask (255.255.0.0).
8.2.2 Board Info
This page displays version information about systems hardware and firmware.
Parameter Description Hardware Version Firmware Version Port Number
Provides information on the hardware version Provides information on the firmware version Provides information on the number of ports available
21
-
VOLKTEK NSH-5509 MANAGED 8-PORT 10/100 + 1-PORT 100-FX SWITCH
8.2.3 DHCP Configuration
Disable or enable the DHCP Client role of the Switch. Once the DHCP Client is enabled, the IP address of the Switch is obtained from DHCP Server and you need to check the new IP address via the Serial Console.
If you change the setting of DHCP Client, and click Apply, the system will notify you to save the setting with a pop-up dialog box.
8.3 Configuration
Port Configuration This section allows you to view and change the parameter settings for the individual ports on the Switch. See screen shot and table below for adjustable parameters.
22
-
VOLKTEK NSH-5509 MANAGED 8-PORT 10/100 + 1-PORT 100-FX SWITCH
8.3.1 Port Configuration
Click on each parameter field to modify the desired setting, then click Undo to restore previously saved configurations or click Apply to implement newly entered information. See description below: Parameter Description Port Name Type Admin Speed: Status Speed: Setting Duplex: Status Duplex: Setting
Port type and number Assign a name to each port to keep record of your connections Type of connector for each port (auto-detects fiber or RJ-45) Enable or disable admin configurations Provides information on speed at which ports are currently operating Set speed for RJ-45 ports. (The speed for fiber ports is fixed) Provides information on Duplex Status Select half / full duplex modes
Link Auto Flow Control
Provides information on link status Enable / Disable Auto-negotiation on copper ports Enable / Disable flow control for each port
Note: Disable the Auto (Auto-negotiation) function to configure Speed and Duplex. Click on Undo to restore previously saved configurations or click on Apply to implement newly entered information.
23
-
VOLKTEK NSH-5509 MANAGED 8-PORT 10/100 + 1-PORT 100-FX SWITCH
8.3.2 Port Status
This window offers at-a-glance status reporting for Switch operations. Click on the Port Configuration button to return to the Port Configuration window if you need to change any settings.
8.3.3 Ethernet Loop Detection
Ethernet Loop Detection is used to detect Ethernet Loop conditions on active ports. Ethernet Loops cause broadcast storms and crash the whole network. Set Protection to enable or disable the Ethernet Loop Detection function of the Switch, and enable or disable it on the specific port. For MAC Address, users can use the default one as the destination MAC address for Ethernet Loop Detection. The default MAC Address is a multicast address. Some network switch does not forward packets with unrecognized multicast MAC address and discard those test packets sent out by the Switch for Ethernet Loop Detection. In this situation, the function cannot be correctly executed. Users can set another unicast MAC Address to cope with this condition. If the port is blocked by Switch for detected loop, it needs to be enabled manually after removing the Ethernet Loop.
24
-
VOLKTEK NSH-5509 MANAGED 8-PORT 10/100 + 1-PORT 100-FX SWITCH
8.4 Bridge Menu
The Bridge menu is used for configuring the Spanning Tree Algorithm and Xpress Ring settings, as well as the traffic class priority threshold and the address aging time. Xpress Ring offers a very fast link-failure recovery time of 50ms, user must select the role of the Switch (arbiter or forward) and which two ports will be part of the Xpress Ring network. The Spanning Tree Algorithm is used for detecting and disabling network loops, and to provide backup links between switches, bridges or routers. This allows the switch to communicate and interact with other bridging devices (i.e. STA-compliant devices) in a network to ensure that only one route exists between any two stations, and it provides redundant or backup links that automatically take over when a primary link goes down.
8.4.1 Bridge Configuration (Enable / Disable RSTP, etc.)
Select the appropriate mode (protocol) for your network implementation, then click Apply to implement newly entered information, or click Undo to restore previously saved configurations. Parameter Description Disable RSTP (802.1W) Xpress Ring Port 1~9
Dont enable RSTP or Xpress Ring Enable Rapid Spanning Tree Protocol Enable Xpress Ring function, redundant link with fastest recovery time: less than 50ms Enable (V): This port participates in the STP/RSTP algorithm execution of the Switch when RSTP (802.1W) is enabled. Disable (_): This port doesn't participate in the STP/RSTP algorithm execution of the Switch when RSTP (802.1W) is enabled.
25
-
VOLKTEK NSH-5509 MANAGED 8-PORT 10/100 + 1-PORT 100-FX SWITCH
8.4.2 RSTP System Configuration
This screen allows the user to enter the RSTP parameters for the Switch. Please note: users must select RSTP (802.1W) under Bridge Configuration to perform this configuration. Otherwise, this option will not be accessible.
Enter the appropriate values, then click on Apply to implement newly entered information or click on Undo to restore previously saved configurations. Parameter Description RSTP Force Version Bridge Priority Hello Time Max. age Forward Delay
Force the spanning tree algorithm to run on RTP or RSTP protocol version Set the bridge priority. The limit is given between 0 (the highest priority) and 65535 (the lowest priority). Bridge priority is used in selecting the root device, root port, and designated port. The device with the highest priority becomes the STA root device. However, if all devices have the same priority, the device with the lowest MAC address will then become the root device. Set the interval between hello bridge protocol data units (BPDUs) sent by root switch configuration messages. The limit given is from 1 10 seconds. Set the interval between messages that the spanning tree receives from the root switch. If a switch does not receive a bridge protocol data unit (BPDU) message from the root switch within this interval, it will reconfigure the spanning-tree topology. The limit given is from 6 40 seconds. Set Forward Delay. The limit given is from 4~30 seconds. The forwarding time specifies how long each of the listening and learning states last before the port begins forwarding.
8.4.3 RSTP Per-Port Configuration
STP/RSTP allows the Switch to assign a priority status to each of its ports, with respect to other networking nodes in the network. In other words, STP/RSTP determines the best link for data to flow, given the priority level of each node on the network. Ensure that this function is activated to avoid collisions and when setting up backup links.
26
-
VOLKTEK NSH-5509 MANAGED 8-PORT 10/100 + 1-PORT 100-FX SWITCH
Click on each parameter field to modify the desired setting, then click on Undo to restore previously saved configurations or click on Apply to retain newly entered information. See description below: Parameter Description Port Type Priority Cost Edge P2P
Set the priority of each port. The limit given is from 1 255. The lowest number means highest priority. The default priority is set to 128 the midpoint of this limit Set the cost assigned to each port. This will determine the route of information flow. The higher the cost the less suitable the port is to be a node for the STP. On: the port is connected to an end node, e.g., a network card installed in a PC Off: the port is connected to a bridged node On: the link type of the port is Point-to-Point, connecting to one BridgeOff: the link type of the port is Shared Medium, connecting to multiple Bridges Auto: the link type is automatically determined
8.4.4 Xpress Ring Configuration
If Xpress Ring was enabled, you must set the Switchs role in the Xpress Ring network and the ports that will be part of the Xpress Ring. Every switch participated the Xpress Ring environment should be exactly defined.
27
-
VOLKTEK NSH-5509 MANAGED 8-PORT 10/100 + 1-PORT 100-FX SWITCH
Xpress Ring Role Arbiter the Switch which receives status reports submitted from other Switches of the ring and determines ring recovery behavior. Forward the Switch which is not the Arbiter of the ring and will forward the received status reports on the other side of ring ports. Select Ring Port-1: the first port composes the Xpress Ring of this switch. Select Ring Port-2: the second port composes the Xpress Ring of this switch. Port status: display the port status. Forwarding means packets transmitting and receiving were at normal status on this port, Blocking means this port was disabled or link was down.
8.5 VLAN Menu
A VLAN is a network of computers behaving as though they are connected to the same segment, even though their physical location may be on a different segment of a LAN altogether. VLANs are configured through software rather than hardware, which make them extremely flexible. Some of the advantages of VLANs are: When a computer is physically moved to another location, it can stay on the same
VLAN without any hardware reconfiguration because VLANs are not limited by hardware constraints.
VLANs can be configured to define a network into various logical configurations. For
example, VLANs can define a network by application. In this scenario, a company might create one VLAN for multimedia users and another for e-mail users.
VLANs can also define a network by department. For example, a company might
have one VLAN for its Engineering Department, another for its Marketing Department, and another for its Sales Department.
VLANs can also be set up according to the organizations internal structure. For
example, the company president might have his/her own VLAN, the executive staff
28
-
VOLKTEK NSH-5509 MANAGED 8-PORT 10/100 + 1-PORT 100-FX SWITCH
might have a different VLAN, and the remaining employees might have yet a different VLAN.
As these examples show, VLANs offer incomparable flexibility. The following section describes how VLANs can be deployed using the Switch.
8.5.1 VLAN Type (VLAN Configuration)
The VLAN Type menu let users select the VLAN type of the Switch. Parameter Description
Disabled The VLAN function is disabled.
Port-Based Tag-Based
The VLAN function is enabled for Port-based VLANs. The VLAN function is enabled for IEEE802.1Q VLANs
8.5.2 VLAN Configuration (Port-based)
The Port-based menu is for configuration of Port-Based VLAN. It is enabled only when the VLAN Type is set as Port-Based.
29
-
VOLKTEK NSH-5509 MANAGED 8-PORT 10/100 + 1-PORT 100-FX SWITCH
For each port the user must click on the checkboxes of the ports to decide which port is allowed to switch frames from the configured port. Click on Apply to implement newly entered information or click on Undo to restore previously saved configurations. Enable / Disable Switch Management: Enable: The user can manage the Switch as Web/Telnet Client or SNMP Manager via this port. Disable: The Switch is not manageable from Web/Telnet Client or SNMP Manager via this port.
8.5.3 Tag-based VLAN Port Configuration (Port Info)
The menu Tag-Based is for configuration of Tag-Based VLAN. It is enabled only when the VLAN Type is set as Tag-Based. The sub-menu lets users configure the way in which each port treats the incoming frames that are marked for Tag-based VLANs. Parameter Description VID Priority Ingress Filter 1 (Non-Member) and Filter 2 (Untagged)
Set the VLAN ID. The limit is 1 to 4095. The VLAN ID is assigned to all untagged frames received on this port. Set VLAN Priority. The limit given is between 0 7. 0 is the lowest priority and 7 is the highest priority. z Non-Member (1): Forward and Untagged (2): Forward
Forward the VLAN-tagged frames that are not members of any VLAN in which the port is participating, and forward all untagged frames.
z Non-Member (1): Drop and Untagged (2): Forward Drop the VLAN-tagged frames which are not members of any VLAN
of which the port is participating, and forward all untagged frames. z Non-Member (1): Drop and Untagged (2): Drop
Drop the VLAN-tagged frames which are not members of any VLAN of which the port is participating, and drop all untagged frames.
30
-
VOLKTEK NSH-5509 MANAGED 8-PORT 10/100 + 1-PORT 100-FX SWITCH
Isolation Double Tag
Enable The port is isolated. Isolated ports belonging to the same VLAN do not communicate with each other this is generally set for security reasons. The isolated ports communicate only with the trunk ports, which should NOT be set as isolated. Disable The port is not isolated and can communicate with all ports of the VLANs. Enable: The egress frames are double-tagged. Disable: The egress frames are not double-tagged.
8.5.4 Tag-based Info (VLAN Table)
The sub-menu Tag-based Info let users add, modify, or delete entries in the Tag-based VLAN Table, the configurations of 802.1Q VLANs and the participating ports. Up to 64 VLANs can be configured on the Switch. On the left is the Tag-based VLAN Table, where existing VLANs can be modified or deleted. In the combo box at the top is the VLAN ID (VID) numbers (1, 2, etc.) of the previously configured VLANs. Users can click on a VID number to display the port information of that VLAN. The following table describes the port parameters in regard to 802.1Q VLANs:
31
-
VOLKTEK NSH-5509 MANAGED 8-PORT 10/100 + 1-PORT 100-FX SWITCH
Parameter Description Member Untagging Tagging Non-member
The Port is a member of the specified VLAN and the frames of this VLAN can be switched through this port, but the tagging information in the frame header is not modified by the Switch. The port is an untagging port (as defined in 802.1Q) that is participating in the VLAN. In such an untagged port the Switch will strip off the 802.1Q tag from the incoming and outgoing frames if they are tagged in such a way. This is used for sending frames to non-802.1Q-compliant devices. The port is a tagging port (as defined in 802.1Q) and is participating in the VLAN. The Switch will put the VLAN information of the port including VID and Priority into the header of the untagged frames coming in or transmitted from the port. The tagged VLAN information in the frames can later be used by other 802.1Q-compliant devices for forwarding decisions. The port is not participating in the VLAN as identified by the selected VID (VLAN ID).
Click the Modify button to modify configurations of the selected VLAN according to the settings on the table. Click the Delete button to delete the VLAN entries of the selected VID. On the right is the Add VLAN Configuration work area where you can add VLAN configuration entries onto the Tagging VLAN Table. Enter a valid configurable 802.1Q VID ranging from 1 ~ 4094 into the field on the first row. Next, specify for each port the parameters described in the table above this will decide if the specific port will participate in that specific VID and how it will participate. Click the Apply button to add the new VLAN to the Tag-based VLAN Table.
8.5.5 Management VLAN
The Management VLAN is the VLAN ID that in-band management stations belong to. The Port VLAN ID of the port that receives the management messages must be the same as the Management VLAN ID. The Web or Telnet session will be disconnected after the Management VLAN is changed.
32
-
VOLKTEK NSH-5509 MANAGED 8-PORT 10/100 + 1-PORT 100-FX SWITCH
8.6 Rate Control
Use this screen to set the Jumbo packet limit and the Rate Control for each port of the Switch.
Click on each parameter field to modify the desired setting, then click Apply to implement newly entered information or click Undo to restore previously saved configurations. Note: The maximum limited rate is 64Mbps. Parameter Description Port Ingress Limit Mode
Select to block the specified traffic from the port. All Frames: Restrict all kinds of packets (Default) exceeding the rate set in the Ingress/Egress Rate fields Multicast/Broadcast & Flooded unicast: Restrict these packets when exceeding the set value Multicast/Broadcast only: Restrict these packets when exceeding the assigned value Broadcast only: Restrict broadcast only packets when exceeding the assigned limit
Ingress / Egress Rate Set the threshold of traffic of limited packets for each port in the Switch
33
-
VOLKTEK NSH-5509 MANAGED 8-PORT 10/100 + 1-PORT 100-FX SWITCH
8.7 Port Mirroring
Set the port mirroring option to monitor data being transmitted through a specific port.
Click on each parameter field to modify the desired setting, then click Apply to implement newly entered information or click Undo to restore previously saved configurations. Parameter Description
Mirroring Mode
Select appropriate mode Disable: Mirror mode is disabled Ingress & Egress: Monitor both incoming and outgoing traffic Egress: Monitor only outgoing traffic
Monitoring Port Select the port which will do the monitoring
Monitored Port Select the port that needs to be monitored
8.8 Trunk Configuration
8.8.1 Aggregator Setting
34
-
VOLKTEK NSH-5509 MANAGED 8-PORT 10/100 + 1-PORT 100-FX SWITCH
Port Trunking defines a network link aggregation and trunking method which specifies how to create a single high-speed logical link that combines several low-speed physical links. Use the Trunk Configuration page shown above to create trunk groups. The Switch supports a maximum of four trunk groups for 100Mbps ports. Each trunk group in groups 1~4 may be comprised of up to four ports, selected from any combination of 100Mbps ports. Note: Before you configure trunk group, check the setting of bridge function. If bridge function has been enabled, the system will display an error message when you click Apply.
Error: Cannot save while Bridge Function is enabled. If the trunk group formed with another switch using protocol-based LACP, click to enable LACP.
8.8.2 LACP Configuration
Port State Activity will determine whether the port will actively initiate the LACP negotiation. Enable Active if the port is active for LACP negotiation. System priority is combined with the Switchs MAC address to form the Link Aggregation Group (LAG) ID. This ID is used to indicate a specific LAG during LACP negotiations with other systems.
8.8.3 LACP Link Status
35
-
VOLKTEK NSH-5509 MANAGED 8-PORT 10/100 + 1-PORT 100-FX SWITCH
This window displays the LACP Link Status, including System Priority, MAC address, Port ID, Port Key, and Port Priority of Actor and Partner roles of the formed LACP groups.
8.9 IGMP Menu
Using the IGMP Menu The IGMP menu is used for configuring IGMP snooping. IGMP means "Internet Group Management Protocol". It is a protocol through which hosts can register with their local router for multicast services. If there is more than one multicast router on a given sub-network, one of the routers is elected and assumes the responsibility of keeping track of group membership.
8.9.1 IGMP Configuration
This menu allows the user to Enable/Disable IGMP Snooping and IGMP Query. Port 1~9 IGMP Static: Enable (V): Multicast packets will be forwarded to IGMP Static ports without the learning process and timeout of multicast group membership. It is generally applied to those ports of uplinks or A / V equipment which will not be flexibly reconfigured. Note: In order to keep the switch traffic efficient, the last byte of the IP address should not be the same as in the IGMP group. E.g. if the Switchs IP address is 192.168.0.10 and the IGMP router / switchs IP address is 192.168.21.10, this will make the switch less efficient.
36
-
VOLKTEK NSH-5509 MANAGED 8-PORT 10/100 + 1-PORT 100-FX SWITCH
8.9.2 IGMP Groups Status
This window will display the IGMP group status of the port members if IGMP traffic is present.
8.10 MAC Menu
The MAC menu will enable the following configurations:
8.10.1 MAC Table Status
The user can view the MAC Table by selecting this function. On this page the mark P means the MAC is learned from a downlink port and the mark T means the MAC is learned from a trunk port.
8.10.2 Lock Learning MAC
The user can stop specific port(s) from learning MAC addresses. Select the port(s) that need to be locked so that they cannot learn MAC addresses.
37
-
VOLKTEK NSH-5509 MANAGED 8-PORT 10/100 + 1-PORT 100-FX SWITCH
8.10.3 Static MAC Configuration
Here the user can select a static MAC configuration for certain port(s) of the Switch.
Add the valid MAC address in the MAC field, then select the priority and port number. Press Apply to implement the input. If you want to deny a host to access network via this switch, type in the MAC address and select none at port number field. The Static MAC addresses and their settings will be displayed in the table below the input bar. Press Delete to void the configuration.
38
-
VOLKTEK NSH-5509 MANAGED 8-PORT 10/100 + 1-PORT 100-FX SWITCH
8.10.4 MAC Limit Configuration
The MAC Limit Configuration menu lets the user limit the number of incoming MAC addresses per port. If the user wants to disable this function, select Disable from the combo box Mac Limit Function on the upper left. The Limit Quantity range is 1~20 per port. The MAC addresses learned are recorded on a per-port basis. Only the frames with such recorded MAC addresses will be forwarded. This learning process will be conducted every three minutes. So, if users change the NIC of the PC or IP appliance, the new MAC address will be learned in three minutes by the Switch, within the set quantity limitations. The MAC Limit Function can be disabled or enabled per port, under the parameter labeled Action in the table. Generally this function is only enabled for downlink ports.
8.11 QoS Menu
QoS (Quality of Service) refers to the mechanisms in the Switchs network software that make the actual determinations of which packets have priority. The Switch supports advanced QoS features like scheduling, classification and policing.
8.11.1 Base Configuration
This window offers user to perform the basic configuration for Quality of Service. Schedule Mode: weighted fair queuing or all high before low
39
-
VOLKTEK NSH-5509 MANAGED 8-PORT 10/100 + 1-PORT 100-FX SWITCH
Weighted Fair Queuing (WFQ) is a packet-scheduling technique allowing guaranteed bandwidth services. The purpose of WFQ is to let several sessions share the same link. Once you adjusted the basic settings, use the Apply button to implement these changes.
8.11.2 Tag Priority
The user can define up to eight different priority values for the Tagged VLAN frames. Select the priority queue number for the Switch to map the MAC frames into different priority queues: i.e. High, Preferred, Normal or Low. Click Apply to implement the settings.
40
-
VOLKTEK NSH-5509 MANAGED 8-PORT 10/100 + 1-PORT 100-FX SWITCH
8.11.3 IP ToS Priority
The IP ToS (Type of Service) Priority menu provides different priorities. The user can select the most suitable combination.
8.12 Management Configuration
8.12.1 Serial Port Configuration
Here the user can see the serial port configuration that can be utilized while accessing the switch via Console port.
Click on each parameter field to modify the desired setting, then click Apply to implement newly entered information or click Undo to restore previously saved configurations. Parameter Description Management Mode, Baud Rate, Data Bits, Stop bits, Parity Time Out
Default COM port properties Set the time (seconds) for auto-logout in case there is no activity for that time period
41
-
VOLKTEK NSH-5509 MANAGED 8-PORT 10/100 + 1-PORT 100-FX SWITCH
8.13 SNMP Configuration
8.13.1 SNMP Communities
Click on each parameter field to modify the desired setting, then click Apply to implement newly entered information or click Undo to restore previously saved configurations. Parameter Description GET SET
Read only community name, the default is public. Read/Write community name, the default is private.
Note: You can use an external SNMP-based application to configure and manage the switch. This management method requires the SNMP agent on the switch and the SNMP Network Management Station to use the same community string. This management method, in fact, uses two community strings: the GET community string and the SET community string. If the SNMP network management station only knows the SET community string, it can read and write to the MIBs (Management Information Bases of the devices), but, if it only knows the GET community string, it can only read the MIBs.
8.13.2 IP Trap Manager
The following tables describe how to specify the management stations that will receive authentication failure messages or other trap messages from the switch. Up to 5 trap managers may be assigned.
42
-
VOLKTEK NSH-5509 MANAGED 8-PORT 10/100 + 1-PORT 100-FX SWITCH
Click on each parameter field to modify the desired setting, then click on Apply to implement newly entered information or click on Undo to restore previously saved configurations. Parameter Description IP Address Community Name Status
Enter the IP address of special host that will be received traps. Enter community name. Disable or enable trap distribution.
8.14 E-mail Alarm Configuration
The Switch can send alarm notifications via e-mail to assigned e-mail addresses in case of any abnormal events. Up to 5 e-mail addresses can be assigned.
Click on each parameter field to modify the desired setting, then click on Apply to implement newly entered information or click on Undo to restore previously saved configurations. Parameter Description E-mail Alarm Mail Server IP From To Alarm Type
Enable / Disable e-mail alarm notification (Default = Disable) Enter the IP address of the mail server Valid e-mail address assigned to the Switch E-mail address(es) to which e-mail will be sent (maximum of 5) Enable / Disable the type of event that should trigger an e-mail alarm
43
-
VOLKTEK NSH-5509 MANAGED 8-PORT 10/100 + 1-PORT 100-FX SWITCH
8.15 User Configuration
If this is the first time logging in to the configuration program, then the default user name is admin with no password. The user level access allows configuration to all parameters and statistics. You should define a new administrator password, record it and put it in a safe place. Select User Configuration from the Management Setup Menu and enter a user name and/or password for the administrator. Note that passwords can consist of up to 12 and the username up to 20 alphanumeric characters and they are not case sensitive.
Five users can be configured by the Switch. Click on each parameter field to modify the desired setting, then click on Apply to implement newly entered information or click on Undo to restore previously saved configurations. Parameter Description User Name Password User Level
Modify the default Username Modify the User Password Read/Write: Users with the user level Read/Write have administrator privileges and can view and change the configurations of the Switch. Read Only: Users with the user level Read Only can only view some configurations of the Switch.
8.16 Cable Test
Cable Test is used to diagnose the physical copper links connected each port, by separate pairs in a cable. Before the Cable Test is activated, a confirmation message Cable Test will disable normal network functions for one minute. Do you want to continue? will pop up for users confirmation. If the link is well-connected, the Status column will show normal. If the link is disconnected, the Status column will show open, and the Cable Length column will display the estimated distance from the port to the location where the circuit is open.
44
-
VOLKTEK NSH-5509 MANAGED 8-PORT 10/100 + 1-PORT 100-FX SWITCH
8.17 Host Denial of Service
This page enables the user to DENY ACCESS to the Switchs remote management interfaces to ALL IP addresses EXCEPT the maximum of five addresses that can be entered on this page. Note: If Save is activated while the Protection field is enabled and all of the IP Address fields are left blank or are not enabled, the Switchs remote management interfaces will become deactivated until such an act is reversed by accessing the Switch at this page or via the console port. Start by selecting Enable in the Protection field. Then access the first IP Address field and type in the desired IP address and then Enable the field. Remember to select Enable here again and remember to Apply after the desired IP addresses have been entered. A total of five IP addresses can be selected.
8.18 Port Abnormal Traffic Detection
45
-
VOLKTEK NSH-5509 MANAGED 8-PORT 10/100 + 1-PORT 100-FX SWITCH
Here the user can alter per-port configuration to detect abnormal traffic (like broadcast traffic) and temporarily or permanently block ports that detect such traffic.
Use this page to configure all selected ports reaction to abnormal traffic.
If, for instance, the Threshold is 5000 p/s and the Detection Duration is 60 seconds, it means that all enabled ports will be blocked if a transmission load of more than 5000 p/s is experienced on these ports for an uninterrupted period of 60 seconds.
If the Block Duration is set at 600 seconds, these ports will be unblocked again after 600 seconds, but if Block Port Permanently is enabled, the Block Duration (600 seconds) will not apply and the port will be blocked forever or until the manager unblocks it by accessing the Port Settings page.
Change the above variables according to your requirements.
Enable all ports that will partake in Abnormal Traffic Detection according to the above-mentioned parameters. Click Apply to let changes take effect.
8.19 Firmware Download (Upgrade System)
Use the HTTP Download menu to load software updates into the permanent flash ROM in the switch. The download file should be in a binary format, otherwise, the agent will not accept it. The success of the download operation depends on the quality of the network connection. After downloading the new software, the agent will automatically restart itself. See the following figure and table:
46
-
VOLKTEK NSH-5509 MANAGED 8-PORT 10/100 + 1-PORT 100-FX SWITCH
Click on Browse to select the firmware file. Once the selection is made, click Start Upgrade to upgrade the systems. The Switch will restart once the new firmware is uploaded.
Parameter Description File Name Start Upgrade
Use the Browse function to find and select the firmware to be uploaded Click here to upgrade firmware
8.20 Configuration File (System Backup)
The Switch enables the user to get a back-up of the configuration file. This will help the user to install many VOLKTEK switches with the same configurations.
Backup settings: Click the Backup Setting button and a download window for Config.bin will appear. Save the file in a safe location for later retrieval. Restore settings: Click on Browse button to select the downloaded/backed-up configuration file, and then press the Restore Setting button. The Switch will restart and apply the settings as in the configuration file. Parameter Description System Backup Restore Settings
Use this menu to make a backup of the Switchs configurations. To begin, click on the backup setting button. Then follow the prompts to save the Switchs configurations to a designated location. Use this menu to retrieve saved files. Click the browse function to select the correct file. Then click Restore Settings.
47
-
VOLKTEK NSH-5509 MANAGED 8-PORT 10/100 + 1-PORT 100-FX SWITCH
8.21 System Restart Menu Restart Option
Click one of these buttons to reset/restart the system without turning OFF the power. Parameter Description System Restore Factory Default Settings System Reset
Clicking on the Restore button will set the switch back to factory defaults. All saved configurations will be lost. Click on the Reset button to reboot the switch. After rebooting, it is necessary to log in again.
8.22 System Parameter Settings
Click Save button to save system configuration.
48
-
VOLKTEK NSH-5509 MANAGED 8-PORT 10/100 + 1-PORT 100-FX SWITCH
9 Command Line Interface
This section provides some basic instructions for using Command Line Interface to configure the Switch. The system provides CLI user interface via console or telnet. There are five different prompts of command modes: User, Enable, Config, Config-vlan and Config-interface. Mode How to Login/Access Prompt
User Default login level for a valid user account. Hostname>
Enable Type enable in user mode Hostname#
Config Type configure terminal in enable mode Hostname(config)#
Config-vlan Type vlan in config mode Hostname(config-vlan)#
Config-interface Type Interface port-channel < port-list > in config mode Hostname(config-interface)#
For detail command lists, please reference to appendix B.
9.1 Log in
When you connect the system via CLI, the system will prompt you to enter a valid user name and password. The default log-in name is admin with no preset password. The user mode is the default login level for a valid user account. After you log in, type in ? or help followed by Enter key to display a full list of usable commands with explanations of their functions. NSH-5009> help Commands available:
enable exit help history logout ping show ip show system-information
Turn on privileged commands Exit from current mode Show available commands Show a list of previously run commands Disconnect Ping a specified host with IP address Show network configuration Show system configuration
The table above lists and explains all the available commands. Users can refer to the table when configuring the Switch management agent. Type in enable followed by Enter key to access the Enable mode. To access enable mode, you need a read/write privilege level user account.
9.2 Show commands
Where appropriate, a status report can be shown by typing show followed by the parameter name. Type show and press Enter to display a full list of configuration commands:
49
-
VOLKTEK NSH-5509 MANAGED 8-PORT 10/100 + 1-PORT 100-FX SWITCH
NSH-5009# show abnormal cable hdos email-alarm frame igmp interface ip locked-mac logins loop mac mac-limit mirror qos rate_control rmon rstp snmp static-mac system-information trunk version vlan xpress
Show abnormal traffic detection configuration Show cable test results Show Host Denial-of-Service configuration Show email configuration Show switch frame Show switch IGMP Show port configuration Show network configuration Show Lock prevent unknown MAC configuration Show login account information Show loop detection configuration Show switch MAC Show MAC limit configuration Show mirror configuration Show QoS configuration Show rate control configuration Show RMON information Show RSTP configuration Show SNMP configuration Show static unicast MAC configuration Show system configuration Show trunk configuration Show system version Show VLAN configuration Show Xpress Ring configuration
9.3 System configurations
Type configure terminal in enable mode to access the configuration mode. NSH-5009# configure terminal NSH-5009(config)# You can type in ? or help followed by Enter key to display a full list of help commands with explanations of their functions. For detail command lists, please reference to appendix B.
9.3.1 Port configurations
Change the configuration mode to configure parameters of switch ports with the following command: NSH-5009(config)# interface port-channel For example, use this command to access port 1.
NSH-5009(config)# interface port-channel 1 NSH-5009(config-interface)#
50
-
VOLKTEK NSH-5509 MANAGED 8-PORT 10/100 + 1-PORT 100-FX SWITCH
Then, you can type in ? or help followed by Enter key to display a full list of help commands with explanations of their functions.
9.3.2 Spanning Tree Protocol (STP) configurations
STP allows the Switch to assign a priority status on the Switch with respect to other networking nodes in the network. Ensure that this function is activated when setting up backup links and to avoid loop. Type a question mark ? after spanning-tree command to display a full list of help commands with explanations. NSH-5009(config)# spanning-tree enable Enable RSTP on the switch force-version Set RSTP force version forward-delay Set RSTP forward delay hello-time Set RSTP hello time max-age Set RSTP max age priority Set RSTP switch priority
9.3.3 Virtual LAN configurations
Before you configure VLAN parameters, you should setup the VLAN type to Tag-Based. For example, use the following commands to setup tag-based VLANs: NSH-5009(config)# vlan-type 802.1q NSH-5009(config)# vlan 1 NSH-5009(config-vlan)# Type a question mark ? or help followed by Enter to display a full list of help commands with explanations. NSH-5009(config-vlan)# help Commands available: exit Exit from current mode help Show available commands history Show a list of previously run commands logout Disconnect ping Ping a specified host with IP address manage This VLAN Group ID is a management VLAN member Specify the port(s) you don't want to
modify all outgoing frames transmitted with this VLAN Group ID
non-member Specify the port(s) don't a member for this VLAN Group ID
tagging Specify the port(s) you want to tag all outgoing frames transmitted with this VLAN Group ID
untagging Specify the port(s) you don't want to tag
51
-
VOLKTEK NSH-5509 MANAGED 8-PORT 10/100 + 1-PORT 100-FX SWITCH
all outgoing frames transmitted with this VLAN Group ID
9.3.4 SNMP configurations
Changing or setting SNMP parameters to accommodate the network management systems as needed. Type a question mark ? after snmp command to display a full list of help commands with explanations. NSH-5009(config)# snmp contact Set system contact name getcommunity Set GET community location Set system location name Set system name setcommunity Set SET community trapcommunity Set TRAP community trapenable Set TRAP enable trapip Set TRAP IP address
52
-
VOLKTEK NSH-5509 MANAGED 8-PORT 10/100 + 1-PORT 100-FX SWITCH
10 Troubleshooting
The network administrator can observe and monitor most areas of the Switch status using the LED indicators on the front panel to quickly identify problems. This section contains a few of the more common problems that may arise and possible solutions. Symptom: Power indicator does not light up after power on. Cause: Defective power outlet or power cord. Solution: Verify if the power outlet is functioning normally by plugging in another
properly operating device. Connect the power cord to another device to test. If these two tests fail to resolve the problem, replace the power supply unit.
Symptom: Link indicator does not light up after making a connection. Cause: Network cable or fiber/copper port is defective. Solution: Ensure that the attached device and Switch are powered on. Verify that
the fiber and/or copper cable has been properly connected to both devices. Make sure that the cabling distance does not exceed specified limits. Inspect cable for defects and replace if necessary.
Symptom: Unit powers off during operation after a period of time. Cause: Loose power connections, power surges/loss or unavailability of
redundant power. Solution: Ensure that all power connections are secure and that the unit fans have
proper ventilation. If unable to correct the problem by above measures, it may be necessary to replace internal power supply unit.
53
-
VOLKTEK NSH-5509 MANAGED 8-PORT 10/100 + 1-PORT 100-FX SWITCH
11 Appendix A
11.1 RJ-45 Cables
When connecting your network devices, use a standard Category 3 eight-way cable for a 10Base-T configuration and a Category 5 cable for 100Base-TX. The pin assignments are as follows:
Pin 1 TD+ Pair 2 White/Orange Pin 2 TD- Pair 2 Orange/White Pin 3 RX+ Pair 3 White/Green Pin 4 N/A Pair 1 Blue/White Pin 5 N/A Pair 1 White/Blue Pin 6 RX- Pair 3 Green/White Pin 7 N/A Pair 4 Brown/White Pin 8 N/A Pair 4 Brown/White
Application Cable Type Application
Switch to
Switch or
Network Adapter
Straight-through Cable
Switch Hub End 1 1 2 2 3 3 6 6
Converter to
Switch
Cross-Over Cable
Switch Converter End #1 End #2 1 1 2 2 3 3 6 6
Remark: The Switch features automatic MDI/MDI-X and NWay on RJ-45 ports.
11.2 Console Cable (RJ-45 to DB-9)
When connecting your Switchs console port to your COM port, use the provided console cable. The pin assignments are as follows.
RJ-45 pin assignment
54
-
VOLKTEK NSH-5509 MANAGED 8-PORT 10/100 + 1-PORT 100-FX SWITCH
RJ-45 (8-pin) to DB9 (F) pin assignment
11.3 SNMP Trap List
1. Switch Traps Group (private) z Cold start z Warm start z Link up z Link down z System configuration change
2. MIB-II Traps
z Cold start z Warm start z Link up z Link down z Authentication failure
55
-
VOLKTEK NSH-5509 MANAGED 8-PORT 10/100 + 1-PORT 100-FX SWITCH
12 Appendix B
Command Summary
12.1 Command Mode Summary
Mode How to Login/Access Prompt
User Default login level for a read-only account. Hostname>
Enable Type enable in User mode Hostname#
Config Type configure terminal in Enable mode Hostname(config)#
Config-vlan Type vlan in Config mode Hostname(config-vlan)#
Config-interface Type interface port-channel < port-list> in Config mode Hostname(config-interface)#
12.2 Command Summary: User Mode (read privilege)
Command Description
enable Turn on privileged commands
exit Exit from current mode
help Show available commands
history Show a list of previously run commands
logout Disconnect
ping Ping a specified host with IP address
show ip Show network configuration
system-information Show system configuration
12.3 Command Summary: Enable Mode (read/write privilege)
Command Description
configure terminal Enter configuration mode
copy config tftp Download config image from switch
firmware tftp Download firmware image from switch
tftp command-text
Upgrade config by command-text file from tftp server
tftp config Upgrade config image from tftp server
56
-
VOLKTEK NSH-5509 MANAGED 8-PORT 10/100 + 1-PORT 100-FX SWITCH
tftp firmware Upgrade firmware image from tftp server
disable Turn off privileged commands
enable Turn on privileged commands
exit Exit from current mode
help Show available commands
history Show a list of previously run commands
ping Ping a specified host with IP address
logout Disconnect
reset default Reset configuration to the factory default settings
system Restart the system
show abnormal Show abnormal traffic detection configuration
cable all Show cable test results of all ports
port Show cable test results of individual port
hdos Show Host Denial-of-Service configuration
email-alarm Show email configuration
frame Show switch frame
igmp Show switch IGMP
interface Show port configuration
ip Show network configuration
locked-mac Show lock prevent unknown MAC configuration
logins Show login account information
loop Show loop detection configuration
mac Show switch MAC
mac-limit Show MAC limit configuration
mirror Show mirror configuration
qos schedule Show QoS schedule
tag-enable Show QoS tag
ip-enable Show QoS ip-priority
ip-over-tag Show QoS ip-over-tag
tag-pri Show QoS tag-pri
ip-tos-pri Show QoS ip-tos-pri
57
-
VOLKTEK NSH-5509 MANAGED 8-PORT 10/100 + 1-PORT 100-FX SWITCH
rate_control Show rate control configuration
rmon Show RMON information
rstp Show RSTP configuration
snmp Show SNMP configuration
static-mac Show static unicast MAC configuration
system-information Show system configuration
trunk Show trunk configuration
version Show system version
vlan type Show VLAN type
port-base Show port-based VLAN configuration
tag-base management-vlan
Show tag-based VLAN management-VLAN
port-info Show tag-based VLAN port-info
vlan-id Show tag-based VLAN VLAN-id
vlan-table Show tag-based VLAN VLAN-table
xpress Show Xpress Ring configuration
write memory Save configuration
12.4 Command Summary: Configuration Mode (read/write privilege)
Command Description
exit Exit from current mode
help Show available commands
history Show a list of previously run commands
logout Disconnect
ping Ping a specified host with IP address
abnormal Set abnormal traffic detection configuration
detection Enable/Disable abnormal traffic detection
duration Detection Duration in seconds
interval Set Protection interval in seconds
permanently Block port permanently?
threshold Set Threshold of traffic detection(pkts/sec)
dhcp Set this system to be a DHCP client or not
58
-
VOLKTEK NSH-5509 MANAGED 8-PORT 10/100 + 1-PORT 100-FX SWITCH
disable DHCP disable
enable DHCP enable
hdos Set Host Denial-of-Service configuration
ip Set acceptable ip for HDoS protection (index:1-5)
ip-enable Enable/Disable individual ip for HDoS protection (index:1-5)
protection Enable/Disable Host Denial-of-Service protection
email-alarm Set email alarm configuration
disable Disable email alarm
enable Enable email alarm
from Set email from [string]
server Set email server [IPstring]
to
Set email to [id] [string] [enable|disable]
type Set email alarm type
gateway Set gateway
igmp Set IGMP
query-mode Set IGMP query mode
snooping Set IGMP snooping
static Set IGMP static port
interface port-channel Enter interface configuration mode
ip Set the IP Address
lacp Set LACP
group Set LACP or static trunk group
port Set LACP port state active or passive
priority Set system priority for LACP
restart Store LACP configurations and restart
logins Modify login account
loop detection disable Disable loop Detection
enable Enable loop Detection
mac Set loop detection test frame MAC address
port Enable/Disable individual port loop detection
mac-limit Set MAC limit configuration
mirror mode Set mirror mode
59
-
VOLKTEK NSH-5509 MANAGED 8-PORT 10/100 + 1-PORT 100-FX SWITCH
monitoring-port Set mirror monitoring-port
netmask Set netmask
no gateway Set gateway to factory default
igmp snooping Disable IGMP snooping
static Disable IGMP static port
ip Set IP address to factory default
lacp Disable LACP on the switch
logins Reset login password to NULL
netmask Set netmask to factory default
spanning-tree Disable spanning tree
trunk Disable trunk group
vlan Delete static VLAN entry
xpress-ring Disable Xpress Ring
qos schedule all-high-before-low Set QoS schedule all-high-before-low
weighted-fair Set QoS schedule weighted-fair
ip-enable
Set QoS ip-enable
ip-over-tag
Set QoS ip-over-tag
ip-tos-pri
Set QoS ip-tos-pri
tag-enable Set QoS tag-enable
tag-pri
Set QoS tag-pri
rmon clear Clear RMON information
snmp contact Set system contact name
getcommunity Set GET community
location Set system location
name Set system name
setcommunity Set SET community
trapcommunity
Set TRAP community
trapenable Set TRAP enable
trapip Set TRAP IP address
spanning-tree
enable Enable RSTP on the switch
60
-
VOLKTEK NSH-5509 MANAGED 8-PORT 10/100 + 1-PORT 100-FX SWITCH
force-version Set RSTP force version
forward-delay , default:15 Set RSTP forward delay
hello-time , default:2 Set RSTP hello time
max-age , default:20 Set RSTP max age
priority , default:32768 Set RSTP switch priority
static-mac add priority port ...
Add static unicast MAC configuration
delete Delete static unicast MAC configuration
trunk member ...
Set trunk control configuration
vlan Enter tag-based VLAN configuration
vlan-type disable Disable VLAN
port-base Enable port-based VLAN
802.1q Enable 802.1q VLAN(tag-based VLAN)
xpress-ring enable Enable Xpress Ring
port-1 Set Xpress Ring port-1
port-2 Set Xpress Ring port-2
role Set Xpress Ring role
12.5 Command Summary: Interface Mode (read/write privilege)
Command Description