NPE Series Application Drawings · 2016. 1. 30. · 1. Use Navien Cord P #30011612A 2. Set DIP...
Transcript of NPE Series Application Drawings · 2016. 1. 30. · 1. Use Navien Cord P #30011612A 2. Set DIP...
T
Check Valve Circulator
Pressure
Relief
Valve Expansion
Tank
AquastatFull-port
Ball Valve
Mixing
Valve
Storage
Vessel
DHW Circulator
w/Aquastat & Check Valve
These drawing are intended as a guide only and not as a replacement for professionally engineered project drawings. These concept system drawings do not imply compliance with local building codes. Actual installations may vary depending on installation location & parameters and it must be done in accordance with all local building codes. Verify with
Guide Only
NPE Series Application Drawings
CHG
NPE-240S
CHG
NPE-210S
CHG
NPE-180S
20 GoodyearIrvine, CA 92618
800-519-8794
20 GoodyearIrvine, CA 92618
800-519-8794www.Navien.com T
Check Valve Circulator
PressureReliefValve Expansion
Tank
AquastatFull-portBall Valve
Mixing Valve
StorageVessel
DHW Circulatorw/Aquastat & Check Valve
This drawing is intended only as a guide and not as a replacement for professionally engineered project drawings.This concept system drawing does not imply compliance with local building codes. Actual installation may vary depending on installation location & parameters and it must be done in accordance to all local building codes. Verify with local building officials before commencement of system installation.
Drawn By: B. Fenske NPE-S-1-BF02 August 1, 2013
One NPE-S Tankless(Includes NPE-A, Internal Circulation Mode)
NPE-S Series Tankless Water Heater
CHG
Gas
Domestic Cold Water
CondensateDomestic Hot Water
20 GoodyearIrvine, CA 92618
800-519-8794www.Navien.com T
Check Valve Circulator
PressureReliefValve Expansion
Tank
AquastatFull-portBall Valve
Mixing Valve
StorageVessel
DHW Circulatorw/Aquastat & Check Valve
This drawing is intended only as a guide and not as a replacement for professionally engineered project drawings.This concept system drawing does not imply compliance with local building codes. Actual installation may vary depending on installation location & parameters and it must be done in accordance to all local building codes. Verify with local building officials before commencement of system installation.
Drawn By: B. Fenske NPE-S-2-I-BF02 August 1, 2013
Two NPE-S Tankless (Includes NPE-A Internal Circulation Mode)
Recommended Pipe Size/Heater Count 1 Unit - ¾” 2 Units - 1" 3 Units - 1-¼” 4 to 5 Units - 1-½” 6 to 8 Units - 2" 9 to 14 Units - 2-½” 15 to 16 Units - 3"
NPE-S Series Tankless Water Heater
CHG
Gas
Domestic Cold Water
Condensate
CHG
Domestic Hot Water
CommunicationCable
20 GoodyearIrvine, CA 92618
800-519-8794www.Navien.com T
Check Valve Circulator
PressureReliefValve Expansion
Tank
AquastatFull-portBall Valve
Mixing Valve
StorageVessel
DHW Circulatorw/Aquastat & Check Valve
This drawing is intended only as a guide and not as a replacement for professionally engineered project drawings.This concept system drawing does not imply compliance with local building codes. Actual installation may vary depending on installation location & parameters and it must be done in accordance to all local building codes. Verify with local building officials before commencement of system installation.
Drawn By: B. Fenske NPE-S-2LT-I-BF02 August 1, 2013
Two NPE-S Tankless With Two Temperature Operation
Recommended Pipe Size/Heater Count 1 Unit - ¾” 2 Units - 1" 3 Units - 1-¼” 4 to 5 Units - 1-½” 6 to 8 Units - 2" 9 to 14 Units - 2-½” 15 to 16 Units - 3"
NPE-S Series Tankless Water Heater
CHG
Gas
Domestic Cold Water
Condensate
CHG
High Temp Domestic Hot Water
CommunicationCable
Low TempDomestic Hot Water
M
CH
20 GoodyearIrvine, CA 92618
800-519-8794www.Navien.com T
Check Valve Circulator
PressureReliefValve Expansion
Tank
AquastatFull-portBall Valve
Mixing Valve
StorageVessel
DHW Circulatorw/Aquastat & Check Valve
This drawing is intended only as a guide and not as a replacement for professionally engineered project drawings.This concept system drawing does not imply compliance with local building codes. Actual installation may vary depending on installation location & parameters and it must be done in accordance to all local building codes. Verify with local building officials before commencement of system installation.
Drawn By: B. Fenske NPE-S-3-I-BF02 August 1, 2013
Three NPE-S Tankless (Includes NPE-A Internal Circulation Mode)
Recommended Pipe Size/Heater Count 1 Unit - ¾” 2 Units - 1" 3 Units - 1-¼” 4 to 5 Units - 1-½” 6 to 8 Units - 2" 9 to 14 Units - 2-½” 15 to 16 Units - 3"
NPE-S Series Tankless Water Heater
CHG
Gas
Domestic Cold Water
Condensate
CHG
Domestic Hot Water
CommunicationCable
CHG
CommunicationCable
20 GoodyearIrvine, CA 92618
800-519-8794www.Navien.com T
Check Valve Circulator
PressureReliefValve Expansion
Tank
AquastatFull-portBall Valve
Mixing Valve
StorageVessel
DHW Circulatorw/Aquastat & Check Valve
This drawing is intended only as a guide and not as a replacement for professionally engineered project drawings.This concept system drawing does not imply compliance with local building codes. Actual installation may vary depending on installation location & parameters and it must be done in accordance to all local building codes. Verify with local building officials before commencement of system installation.
Drawn By: B. Fenske NPE-S-4-I-BF02 August 1, 2013
Four NPE-S Tankless (Includes NPE-A, Internal Circulation Mode)
Recommended Pipe Size/Heater Count 1 Unit - ¾” 2 Units - 1" 3 Units - 1-¼” 4 to 5 Units - 1-½” 6 to 8 Units - 2" 9 to 14 Units - 2-½” 15 to 16 Units - 3"
NPE-S Series Tankless Water Heater
CHG
Gas
Domestic Cold Water
Condensate
CHG
Domestic Hot Water
CommunicationCable
CHG
CommunicationCable
CHG
CommunicationCable
20 GoodyearIrvine, CA 92618
800-519-8794www.Navien.com T
Check Valve Circulator
PressureReliefValve Expansion
Tank
AquastatFull-portBall Valve
Mixing Valve
StorageVessel
DHW Circulatorw/Aquastat & Check Valve
This drawing is intended only as a guide and not as a replacement for professionally engineered project drawings.This concept system drawing does not imply compliance with local building codes. Actual installation may vary depending on installation location & parameters and it must be done in accordance to all local building codes. Verify with local building officials before commencement of system installation.
Drawn By: B. Fenske NPE-S-5-I-BF02 August 1, 2013
Five NPE-S Tankless (Includes NPE-A, Internal Circulation Mode)
Recommended Pipe Size/Heater Count 1 Unit - ¾” 2 Units - 1" 3 Units - 1-¼” 4 to 5 Units - 1-½” 6 to 8 Units - 2" 9 to 14 Units - 2-½” 15 to 16 Units - 3"
NPE-S Series Tankless Water Heater
CHG
Gas
Domestic Cold Water
Condensate
CHG
Domestic Hot Water
CommunicationCable
CHG
CommunicationCable
CHG
CommunicationCable
CHG
CommunicationCable
20 GoodyearIrvine, CA 92618
800-519-8794www.Navien.com T
Check Valve Circulator
PressureReliefValve Expansion
Tank
AquastatFull-portBall Valve
Mixing Valve
StorageVessel
DHW Circulatorw/Aquastat & Check Valve
This drawing is intended only as a guide and not as a replacement for professionally engineered project drawings.This concept system drawing does not imply compliance with local building codes. Actual installation may vary depending on installation location & parameters and it must be done in accordance to all local building codes. Verify with local building officials before commencement of system installation.
Drawn By: B. Fenske NPE-S-6P-I-BF02 August 1, 2013
Six Plus NPE-S Tankless (Includes NPE-A, Internal Circulation Mode)
Recommended Pipe Size/Heater Count 1 Unit - ¾” 2 Units - 1" 3 Units - 1-¼” 4 to 5 Units - 1-½” 6 to 8 Units - 2" 9 to 14 Units - 2-½” 15 to 16 Units - 3"
NPE-S Series Tankless Water Heater
CHG
GasDomestic Cold Water
Condensate
CHG
Domestic Hot Water
CommunicationCable
CHG
CommunicationCable
CHG
CommunicationCable
CHG
CommunicationCable
CommunicationCable
CHG
Unit 1 Unit 2 Unit 3 Unit 4 Unit 5 Unit 6 - 16. . . . .
20 GoodyearIrvine, CA 92618
800-519-8794www.Navien.com T
Check Valve Circulator
PressureReliefValve Expansion
Tank
AquastatFull-portBall Valve
Mixing Valve
StorageVessel
DHW Circulatorw/Aquastat & Check Valve
This drawing is intended only as a guide and not as a replacement for professionally engineered project drawings.This concept system drawing does not imply compliance with local building codes. Actual installation may vary depending on installation location & parameters and it must be done in accordance to all local building codes. Verify with local building officials before commencement of system installation.
Drawn By: B. Fenske NPE-A-10-E-BF02 August 1, 2013
Ten NPE-S Tankless (Includes NPE-A, Internal Circulation Mode)
Alternative Mounting Shown
Recommended Pipe Size/Heater Count 1 Unit - ¾” 2 Units - 1" 3 Units - 1-¼” 4 to 5 Units - 1-½” 6 to 8 Units - 2" 9 to 14 Units - 2-½” 15 to 16 Units - 3"
NPE-S Series Tankless Water Heater
Gas
Domestic Cold Water
Condensate
Domestic Hot Water
20 GoodyearIrvine, CA 92618
800-519-8794www.Navien.com T
Check Valve Circulator
PressureReliefValve Expansion
Tank
AquastatFull-portBall Valve
Mixing Valve
StorageVessel
DHW Circulatorw/Aquastat & Check Valve
This drawing is intended only as a guide and not as a replacement for professionally engineered project drawings.This concept system drawing does not imply compliance with local building codes. Actual installation may vary depending on installation location & parameters and it must be done in accordance to all local building codes. Verify with local building officials before commencement of system installation.
Drawn By: B. Fenske NPE-S-1-PW-EC-BF02 August 1, 2013
One NPE-S Tankless Using External Pump for Recirculation
with Part #30011612A External Pump Wire
NPE-S Series Tankless Water Heater
Notes:1. Use Navien Cord P #30011612A2. Set DIP Switches on Integrated Controller
#1 – OFF, #2 – OFF, #3 – ON3. Select External Circulator Performance
to be 2 GPM Minimum, 4 GPM Maximum basedon 11 Psi drop @ 4 GPM at tankless
* Refer to NPE Installation Manual for further details
CHG
Gas
Domestic Cold Water
CondensateDomestic Hot Water
20 GoodyearIrvine, CA 92618
800-519-8794www.Navien.com T
Check Valve Circulator
PressureReliefValve Expansion
Tank
AquastatFull-portBall Valve
Mixing Valve
StorageVessel
DHW Circulatorw/Aquastat & Check Valve
This drawing is intended only as a guide and not as a replacement for professionally engineered project drawings.This concept system drawing does not imply compliance with local building codes. Actual installation may vary depending on installation location & parameters and it must be done in accordance to all local building codes. Verify with local building officials before commencement of system installation.
One NPE-S with Storage to meet Flow/Temp Rise Requirements
Drawn By: B. Fenske August 1, 2013NPE-S-1-ST-BF02
NPE-S Series Tankless Water Heater
Domestic Cold Water
Insulated Storage
Tank
T
¾” Min
Domestic Hot Water to Fixtures
Optional DHW
Recirculation
3 or 4TapTank
(A) Tankless Circulator (Bronze or S.S) Selected Shall be 4 GPM Max @ 23' Total Head (10 PSI) + pipe, valves, fittings & tank.
(A)
GasCondensate
CHG
20 GoodyearIrvine, CA 92618
800-519-8794www.Navien.com T
Check Valve Circulator
PressureReliefValve Expansion
Tank
AquastatFull-portBall Valve
Mixing Valve
StorageVessel
DHW Circulatorw/Aquastat & Check Valve
This drawing is intended only as a guide and not as a replacement for professionally engineered project drawings.This concept system drawing does not imply compliance with local building codes. Actual installation may vary depending on installation location & parameters and it must be done in accordance to all local building codes. Verify with local building officials before commencement of system installation.
Two NPE-S with Storage to meet Flow/Temp Rise Requirements
Drawn By: B. Fenske August 1, 2013NPE-S-2-ST-BF02
(A) Tankless Circulator (Bronze or S.S) Selected Shall be 8 GPM Max (4 Per Tankless) @ 23' Total Head (10 PSI) + pipe, valves, fittings & tank.(B) Install Circuit Setters to Maintain Flow into Units @ 4 GPM Maximum
Recommended Pipe Size/Heater Count 1 Unit - ¾” 2 Units - 1" 3 Units - 1-¼” 4 to 5 Units - 1-½” 6 to 8 Units - 2" 9 to 14 Units - 2-½” 15 to 16 Units - 3"
NPE-S Series Tankless Water Heater
(A)Domestic Cold Water
Insulated Storage
Tank
T
Domestic Hot Water to Fixtures
Optional DHW
Recirculation
3 or 4TapTank
CHG
Gas
Condensate
CHG
CommunicationCable
(B) (B)
20 GoodyearIrvine, CA 92618
800-519-8794www.Navien.com T
Check Valve Circulator
PressureReliefValve Expansion
Tank
AquastatFull-portBall Valve
Mixing Valve
StorageVessel
DHW Circulatorw/Aquastat & Check Valve
This drawing is intended only as a guide and not as a replacement for professionally engineered project drawings.This concept system drawing does not imply compliance with local building codes. Actual installation may vary depending on installation location & parameters and it must be done in accordance to all local building codes. Verify with local building officials before commencement of system installation.
Three NPE-S with Storage to meet Flow/Temp Rise Requirements
Drawn By: B. Fenske August 1, 2013NPE-S-3-ST-BF02
(A) Tankless Circulator (Bronze or S.S) Selected Shall be 12 GPM Max (4 Per Tankless) @ 23' Total Head (10 PSI) + pipe, valves, fittings & tank.(B) Install Circuit Setters to Maintain Flow into Units @ 4 GPM Maximum
Recommended Pipe Size/Heater Count 1 Unit - ¾” 2 Units - 1" 3 Units - 1-¼” 4 to 5 Units - 1-½” 6 to 8 Units - 2" 9 to 14 Units - 2-½” 15 to 16 Units - 3"
NPE-S Series Tankless Water Heater
(A)Domestic Cold Water
Insulated Storage
Tank
T
Domestic Hot Water to Fixtures
Optional DHW
Recirculation
3 or 4TapTank
CHG
Gas
Condensate
CHG
CommunicationCable
CHG
CommunicationCable
(B) (B) (B)
20 GoodyearIrvine, CA 92618
800-519-8794www.Navien.com T
Check Valve Circulator
PressureReliefValve Expansion
Tank
AquastatFull-portBall Valve
Mixing Valve
StorageVessel
DHW Circulatorw/Aquastat & Check Valve
This drawing is intended only as a guide and not as a replacement for professionally engineered project drawings.This concept system drawing does not imply compliance with local building codes. Actual installation may vary depending on installation location & parameters and it must be done in accordance to all local building codes. Verify with local building officials before commencement of system installation.
Four NPE-S with Storage to meet Flow/Temp Rise Requirements
Drawn By: B. Fenske August 1, 2013NPE-S-4-ST-BF02
(A) Tankless Circulator (Bronze or S.S) Selected Shall be 16 GPM Max (4 Per Tankless) @ 23' Total Head (10 PSI) + pipe, valves, fittings & tank.(B) Install Circuit Setters to Maintain Flow into Units @ 4 GPM Maximum
Recommended Pipe Size/Heater Count 1 Unit - ¾” 2 Units - 1" 3 Units - 1-¼” 4 to 5 Units - 1-½” 6 to 8 Units - 2" 9 to 14 Units - 2-½” 15 to 16 Units - 3"
NPE-S Series Tankless Water Heater
(A)
Domestic Cold Water
Insulated Storage
Tank
T
Domestic Hot Water to Fixtures
Optional DHW
Recirculation
3 or 4TapTank
CHG
Gas
Condensate
CHG
CommunicationCable
CHG
CommunicationCable
CHG
CommunicationCable
(B) (B) (B) (B)
20 GoodyearIrvine, CA 92618
800-519-8794www.Navien.com T
Check Valve Circulator
PressureReliefValve Expansion
Tank
AquastatFull-portBall Valve
Mixing Valve
StorageVessel
DHW Circulatorw/Aquastat & Check Valve
This drawing is intended only as a guide and not as a replacement for professionally engineered project drawings.This concept system drawing does not imply compliance with local building codes. Actual installation may vary depending on installation location & parameters and it must be done in accordance to all local building codes. Verify with local building officials before commencement of system installation.
Two NPE-S with Two Storage Tanks to meet Flow/Temp Rise Requirements
Drawn By: B. Fenske August 1, 2013NPE-S-2-2ST-BF02
(A) Tankless Circulator (Bronze or S.S) Selected Shall be 8 GPM Max (4 Per Tankless) @ 23' Total Head (10 PSI) + pipe, valves, fittings & tank.(B) Install Circuit Setters to Maintain Flow into Units @ 4 GPM Maximum
Recommended Pipe Size/Heater Count 1 Unit - ¾” 2 Units - 1" 3 Units - 1-¼” 4 to 5 Units - 1-½” 6 to 8 Units - 2" 9 to 14 Units - 2-½” 15 to 16 Units - 3"
NPE-S Series Tankless Water Heater
(A)Domestic Cold Water
Domestic Hot Water to Fixtures
CHG
Gas
Condensate
CHG
CommunicationCable
InsulatedStorage
Tank
InsulatedStorage
Tank
T T
Optional DHW Recirculation
(B) (B)
20 GoodyearIrvine, CA 92618
800-519-8794www.Navien.com T
Check Valve Circulator
PressureReliefValve Expansion
Tank
AquastatFull-portBall Valve
Mixing Valve
StorageVessel
DHW Circulatorw/Aquastat & Check Valve
This drawing is intended only as a guide and not as a replacement for professionally engineered project drawings.This concept system drawing does not imply compliance with local building codes. Actual installation may vary depending on installation location & parameters and it must be done in accordance to all local building codes. Verify with local building officials before commencement of system installation.
Three NPE-S with Two Storage Tanks to meet Flow/Temp Rise Requirements
Drawn By: B. Fenske August 1, 2013NPE-S-3-2ST-BF02
(A) Tankless Circulator (Bronze or S.S) Selected Shall be 12 GPM Max (4 Per Tankless) @ 23' Total Head (10 PSI) + pipe, valves, fittings & tank.(B) Install Circuit Setters to Maintain Flow into Units @ 4 GPM Maximum
Recommended Pipe Size/Heater Count 1 Unit - ¾” 2 Units - 1" 3 Units - 1-¼” 4 to 5 Units - 1-½” 6 to 8 Units - 2" 9 to 14 Units - 2-½” 15 to 16 Units - 3"
NPE-S Series Tankless Water Heater
(A)Domestic Cold Water
Domestic Hot Water to Fixtures
CHG
Gas
Condensate
CHG
CommunicationCable
InsulatedStorage
Tank
InsulatedStorage
Tank
T T
Optional DHW Recirculation
CHG
CommunicationCable
(B) (B) (B)
20 GoodyearIrvine, CA 92618
800-519-8794www.Navien.com T
Check Valve Circulator
PressureReliefValve Expansion
Tank
AquastatFull-portBall Valve
Mixing Valve
StorageVessel
DHW Circulatorw/Aquastat & Check Valve
This drawing is intended only as a guide and not as a replacement for professionally engineered project drawings.This concept system drawing does not imply compliance with local building codes. Actual installation may vary depending on installation location & parameters and it must be done in accordance to all local building codes. Verify with local building officials before commencement of system installation.
Four NPE-S with Two Storage Tanks to meet Flow/Temp Rise Requirements
Drawn By: B. Fenske August 1, 2013NPE-S-4-2ST-BF02
(A) Tankless Circulator (Bronze or S.S) Selected Shall be 16 GPM Max (4 Per Tankless) @ 23' Total Head (10 PSI) + pipe, valves, fittings & tank.(B) Install Circuit Setters to Maintain Flow into Units @ 4 GPM Maximum
Recommended Pipe Size/Heater Count 1 Unit - ¾” 2 Units - 1" 3 Units - 1-¼” 4 to 5 Units - 1-½” 6 to 8 Units - 2" 9 to 14 Units - 2-½” 15 to 16 Units - 3"
NPE-S Series Tankless Water Heater
Condensate
(A)
Domestic Cold Water
Domestic Hot Water to Fixtures
CHG
Gas
CHG
CommunicationCable
InsulatedStorage
Tank
InsulatedStorage
Tank
T T
Optional DHW Recirculation
CHG
CommunicationCable
CHG
CommunicationCable
(B) (B) (B) (B)
20 GoodyearIrvine, CA 92618
800-519-8794www.Navien.com T
Check Valve Circulator
PressureReliefValve Expansion
Tank
AquastatFull-portBall Valve
Mixing Valve
StorageVessel
DHW Circulatorw/Aquastat & Check Valve
This drawing is intended only as a guide and not as a replacement for professionally engineered project drawings.This concept system drawing does not imply compliance with local building codes. Actual installation may vary depending on installation location & parameters and it must be done in accordance to all local building codes. Verify with local building officials before commencement of system installation.
Two NPE-S with Storage to meet Flow/Temp Rise Requirements
Two Temperature System
Drawn By: B. Fenske August 1, 2013NPE-S-2-STLT-BF02
(A) Tankless Circulator (Bronze or S.S) Selected Shall be 8 GPM Max (4 Per Tankless) @ 23' Total Head (10 PSI) + pipe, valves, fittings & tank.(B) Install Circuit Setters to Maintain Flow into Units @ 4 GPM Maximum
Recommended Pipe Size/Heater Count 1 Unit - ¾” 2 Units - 1" 3 Units - 1-¼” 4 to 5 Units - 1-½” 6 to 8 Units - 2" 9 to 14 Units - 2-½” 15 to 16 Units - 3"
NPE-S Series Tankless Water Heater
(A)Domestic Cold Water
Insulated Storage
Tank
T
Domestic Hot Water to Fixtures
Optional DHW
Recirculation
3 or 4TapTank
CHG
Gas
Condensate
CHG
CommunicationCable
(B) (B)
Low TempDomestic Hot Water
M
CH
20 GoodyearIrvine, CA 92618
800-519-8794www.Navien.com T
Check Valve Circulator
PressureReliefValve Expansion
Tank
AquastatFull-portBall Valve
Mixing Valve
StorageVessel
DHW Circulatorw/Aquastat & Check Valve
This drawing is intended only as a guide and not as a replacement for professionally engineered project drawings.This concept system drawing does not imply compliance with local building codes. Actual installation may vary depending on installation location & perameters and it must be done in accordance to all local building codes. Verify with local building officials before commencement of system installation.
One Navien NPE-S Dishwasher ApplicationWith Storage to meet Flow/Temp
Rise Requirements
1. Tankless circulator selected should beapproved for domestic water (S.S. or Bronze).
2. Tankless circulator selected shall be 4 GPM@ 23' H (10 PSI) + pipe, valves, fittings & tank.
3. Storage tank volume size selections:
High Temp (180°F) 6 X dishwasher GPM requirements
Low Temp (140°F) 4 X dishwasher GPM requirements
Drawn By: B. Fenske August 1, 2013NPE-S-1-DW-BF02
NPE-S Series Tankless Water Heater
Opt. Recirculation
Domestic Cold Water
Vacuum Breaker
Insulated Storage
Tank
T
¾” Min
CHG
GasCondensate
20 GoodyearIrvine, CA 92618
800-519-8794www.Navien.com T
Check Valve Circulator
PressureReliefValve Expansion
Tank
AquastatFull-portBall Valve
Mixing Valve
StorageVessel
DHW Circulatorw/Aquastat & Check Valve
This drawing is intended only as a guide and not as a replacement for professionally engineered project drawings.This concept system drawing does not imply compliance with local building codes. Actual installation may vary depending on installation location & perameters and it must be done in accordance to all local building codes. Verify with local building officials before commencement of system installation.
Drawn By: B. Fenske August 1, 2013
Two Navien NPE-S Dishwasher ApplicationWith Storage to meet Flow/Temp
Rise Requirements
NPE-S-2-DW-DHW-BF02
NPE-S Series Tankless Water Heater
(A) Tankless Circulator (Bronze or S.S) Selected Shall be 4 GPM Max per Tankless @ 23' Total Head (10 PSI) + pipe, valves, fittings & tank.(B) Install Circuit Setters to Maintain Flow into Units @ 4 GPM Maximum.
Storage tank volume size selections:High Temp (180°F)
6 X dishwasher GPM requirements Low Temp (140°F)
4 X dishwasher GPM requirements
Opt. Recirculation
Vacuum Breaker
Insulated Storage
Tank
T
1” Min
Domestic Water
To Fixtures
(A)
CHG
Gas
Domestic Cold Water
Condensate
CHG
CommunicationCable
(B) (B)M
CH
20 GoodyearIrvine, CA 92618
800-519-8794www.Navien.com T
Check Valve Circulator
PressureReliefValve Expansion
Tank
AquastatFull-portBall Valve
Mixing Valve
StorageVessel
DHW Circulatorw/Aquastat & Check Valve
This drawing is intended only as a guide and not as a replacement for professionally engineered project drawings.This concept system drawing does not imply compliance with local building codes. Actual installation may vary depending on installation location & perameters and it must be done in accordance to all local building codes. Verify with local building officials before commencement of system installation.
(A) Tankless Circulator (Bronze or S.S) Selected Shall be 4 GPM Max per Tankless @ 23' Total Head (10 PSI) + pipe, valves, fittings & tank.(B) Install Circuit Setters to Maintain Flow into Units @ 4 GPM Maximum.
Storage tank volume size selections:High Temp (180°F)
6 X dishwasher GPM requirements Low Temp (140°F)
4 X dishwasher GPM requirements
Drawn By: B. Fenske August 1, 2013
Two Navien NPE-S Dishwasher ApplicationWith Storage to meet Flow/Temp
Rise Requirements
NPE-S-2-DW-BF02
NPE-S Series Tankless Water Heater
Opt. Recirculation
Vacuum Breaker
Insulated Storage
Tank
T
1” Min
(A)
CHG
Gas
Domestic Cold Water
Condensate
CHG
CommunicationCable
(B) (B)
20 GoodyearIrvine, CA 92618
800-519-8794www.Navien.com T
Check Valve Circulator
PressureReliefValve Expansion
Tank
AquastatFull-portBall Valve
Mixing Valve
StorageVessel
DHW Circulatorw/Aquastat & Check Valve
This drawing is intended only as a guide and not as a replacement for professionally engineered project drawings.This concept system drawing does not imply compliance with local building codes. Actual installation may vary depending on installation location & perameters and it must be done in accordance to all local building codes. Verify with local building officials before commencement of system installation.
(A) Tankless Circulator (Bronze or S.S) Selected Shall be 4 GPM Max per Tankless @ 23' Total Head (10 PSI) + pipe, valves, fittings & tank.(B) Install Circuit Setters to Maintain Flow into Units @ 4 GPM Maximum.
Storage tank volume size selections:High Temp (180°F)
6 X dishwasher GPM requirements Low Temp (140°F)
4 X dishwasher GPM requirements
Drawn By: B. Fenske August 1, 2013
Three Navien NPE-S Dishwasher ApplicationWith Storage to meet Flow/Temp
Rise Requirements
NPE-S-3-DW-DHW-BF02
NPE-S Series Tankless Water Heater
Gas
Condensate
Opt. Recirculation
Vacuum Breaker
Insulated Storage
Tank
T
1-1/4” Min
Domestic Water
To Fixtures
(A)
CHG
Domestic Cold Water
CHG
CommunicationCable
(B) (B)
CHG
CommunicationCable
(B)M
CH
20 GoodyearIrvine, CA 92618
800-519-8794www.Navien.com T
Check Valve Circulator
PressureReliefValve Expansion
Tank
AquastatFull-portBall Valve
Mixing Valve
StorageVessel
DHW Circulatorw/Aquastat & Check Valve
This drawing is intended only as a guide and not as a replacement for professionally engineered project drawings.This concept system drawing does not imply compliance with local building codes. Actual installation may vary depending on installation location & parameters and it must be done in accordance to all local building codes. Verify with local building officials before commencement of system installation.
NPE-S-Combi-AH-BF02 August 1, 2013Drawn By: B. Fenske
Navien NPE-S Series TanklessCombi Use Application with Air Handler
NPE-S Series Tankless Water Heater
AIRFLOW
Opt. AC COILGas
Domestic Cold Water
Domestic Hot Water
ToFixtures
Circulator Requirement:Bronze or Stainless Steel
Select & Set - 4 GPM max @ 23 ft head. (Alternate pump location shown inside AHU)
Condensate
CHGM
CH
20 GoodyearIrvine, CA 92618
800-519-8794www.Navien.com T
Check Valve Circulator
PressureReliefValve Expansion
Tank
AquastatFull-portBall Valve
Mixing Valve
Air Elimination
DHW Circulatorw/Aquastat & Check Valve
This drawing is intended only as a guide and not as a replacement for professionally engineered project drawings.This concept system drawing does not imply compliance with local building codes. Actual installation may vary depending on installation location & parameters and it must be done in accordance to all local building codes. Verify with local building officials before commencement of system installation.
NPE-S-Combi-SS-BF02 August 1, 2013Drawn By: B. Fenske
Navien NPE-S Series TanklessCombi Use Application with Required
SS Heat Exchanger
NPE-S Series Tankless Water Heater
Gas
Domestic Cold Water
Domestic Hot Water
ToFixtures
(A) Circulator Requirement: Bronze or Stainless Steel
Select & Set - 4 GPM max @ 23 ft head.(B) Maximum 30 MBTU’s/Hour & 135°F
Maximum Heating System Temperature with NPE tankless set at 140°F.
Condensate
CH
Closed Loop Heating Fill
SS Heat Exchanger
(B)
FieldSuppliedCirculator
Zone PanelT
(A)
GM
CH
20 GoodyearIrvine, CA 92618
800-519-8794www.Navien.com T
Check Valve Circulator
PressureReliefValve Expansion
Tank
AquastatFull-portBall Valve
Mixing Valve
StorageVessel
DHW Circulatorw/Aquastat & Check Valve
This drawing is intended only as a guide and not as a replacement for professionally engineered project drawings.This concept system drawing does not imply compliance with local building codes. Actual installation may vary depending on installation location & parameters and it must be done in accordance to all local building codes. Verify with local building officials before commencement of system installation.
NPE-S-G-BF02 August 1, 2013Drawn By: B. Fenske
NPE-S Domestic Hot Water Standard Installation with Geothermal or
Desuperheater
Notes:1. For Storage Tank/Geothermal Operation; DIP Switch #6of 10 located on Integrated Display Panel should be set ON (UP).2. With Storage Tank/Geothermal Operation Enabled, NPETankless DHW setting may be set at or near storage tank thermostatic mixing valve temperature output.
Domestic Cold Water
NPE-S Series Tankless Water Heater
DHWSupply
To Fixtures
GasCondensate
CH
DomesticStorage
TankGeothermal Unit
orDesuperheater
G
(A)
(A) Follow GeoThermal Unit and Tank Manufacturer Recommendations and Requirements
20 GoodyearIrvine, CA 92618
800-519-8794www.Navien.com T
Check Valve Circulator
PressureReliefValve Expansion
Tank
AquastatFull-portBall Valve
Mixing Valve
StorageVessel
DHW Circulatorw/Aquastat & Check Valve
This drawing is intended only as a guide and not as a replacement for professionally engineered project drawings.This concept system drawing does not imply compliance with local building codes. Actual installation may vary depending on installation location & parameters and it must be done in accordance to all local building codes. Verify with local building officials before commencement of system installation.
NPE-S-S-BF02 August 1, 2013Drawn By: B. Fenske
NPE-S Domestic Hot Water Standard Installation with Solar Application
Notes:1. For Storage Tank/Solar Operation; DIP Switch #6 of 10located on Integrated Display Panel should be set ON (UP).2. With Storage Tank/Solar Operation Enabled, NPETankless DHW setting may be set at or near storage tank thermostatic mixing valve temperature output.
Domestic Cold Water
NPE-S Series Tankless Water Heater
GasCondensate
CHG
Solar Fill
DHWSupply
To Fixtures