Now in both Single Wall and Double Wall construction…A. Provide a step-up point for Stage II...

17
________________________________ Contact us for more information! 1555 Copperhill Parkway Santa Rosa, CA 95403 Ph: (800) 688-3375 or (707) 523-2050 www.westernfg.com Now in both Single Wall and Double Wall construction… Western Fiberglass offers a complete range of comprehensive, computer designed tank sumps available in multiple diameters and shapes. Unique continuous filament wound construction produces the strongest cylindrical shapes available. Western Fiberglass tank sumps are compatible with all piping systems, approved by major tank manufacturers and by environmental and fire inspectors nationwide. FEATURES/OPTIONS: ¾ 30-Year Warranty ¾ Available With or Without a Bottom ¾ Multiple Lid Combinations ¾ Single Wall and Double Wall Configurations – Please add “DW” to beginning of all part numbers required in double wall ¾ Sumps Available in Alternate Bury

Transcript of Now in both Single Wall and Double Wall construction…A. Provide a step-up point for Stage II...

Page 1: Now in both Single Wall and Double Wall construction…A. Provide a step-up point for Stage II piping that cannot maintain full downward slope towards storage tank or tank(s). B. Prevent

________________________________ CCoonnttaacctt uuss ffoorr mmoorree iinnffoorrmmaattiioonn!!

1555 Copperhill Parkway • Santa Rosa, CA 95403 Ph: (800) 688-3375 or (707) 523-2050

www.westernfg.com

NNooww iinn bbootthh SSiinnggllee WWaallll aanndd DDoouubbllee WWaallll ccoonnssttrruuccttiioonn……

Western Fiberglass offers a complete range of comprehensive, computer designed tank sumps available in multiple diameters and shapes. Unique continuous filament wound construction produces the strongest cylindrical shapes available. Western Fiberglass tank sumps are compatible with all piping systems, approved by major tank manufacturers and by environmental and fire inspectors nationwide.

FFEEAATTUURREESS//OOPPTTIIOONNSS:: 30-Year Warranty Available With or Without a Bottom Multiple Lid Combinations Single Wall and Double Wall Configurations – Please

add “DW” to beginning of all part numbers required in double wall Sumps Available in Alternate Bury

Page 2: Now in both Single Wall and Double Wall construction…A. Provide a step-up point for Stage II piping that cannot maintain full downward slope towards storage tank or tank(s). B. Prevent

TTAANNKK SSUUMMPPSS

DDOOUUBBLLEE WWAALLLL SSPPEECCIIFFIICCAATTIIOONN

CCoonnttaacctt uuss ffoorr mmoorree iinnffoorrmmaattiioonn!!

1555 Copperhill Parkway • Santa Rosa, CA 95403 Ph: (800) 688-3375 or (707) 523-2050

www.westernfg.com

Summary The Double wall Filament wound sump riser and riser reducer shall be installed onto the underground storage tank and in accordance with the manufacturers installation instructions. The Double Wall UST sump riser and the riser reducer shall provide an open piping termination and inspection/service area that is non-permeable to hydrocarbons, compatible with all fuel blends, and will not hold a static electrical charge. The sump system shall contain environmentally hazardous fluids that might leak from piping terminations, fittings and flex-hoses contained within the sump, require no internal back-fill or bracing and be self supporting. The sump shall provide access to the interstitial space to allow for pressure testing to 5 psi and constant, real-time monitoring. The sump shall be manufactured by Western Fiberglass, Inc. System Specifications 1.01 System Suitability The Tank Sump Riser Tube and Riser Reducer Assembly shall: A. Attach to the UST manway, bung fitting or containment collar to prevent the intrusion of

ground water into the sump assembly. B. Be constructed in a double wall configuration with interstitial access provided for constant,

real-time monitoring. C. Be of sufficient size to allow all piping terminations, fittings, equipment, and flex-hoses to be

contained within the Sump Assembly. D. Provide ample area to allow servicing and inspection of all piping terminations, fittings,

equipment, and flex-hoses within the Sump Assembly. E. Contain any release of environmental contaminates from the tank fittings and equipment

contained within the Sump Assembly. F. Provide an interface to the access “street” manway system with sealed water-tight or

friction “lift-lid” Tank Sump Riser Tube Reducer Assembly. G. Be available as a U.L. Listed device if required. 1.02 Construction Specifications A. Meet or exceed United States National Bureau of Standards PS 15-69 for Custom Contact-

Molded Reinforced-Polyester Chemical-Resistant Process Equipment or U.L. Listing if applicable.

B. Be constructed of materials that are not harmful to the environment. C. Be non-permeable to the hydrocarbons and not weakened by exposure to these materials. D. Be suitable for petroleum products and blends including methanol and ethyl alcohol

mixtures. E. Have a thirty (30) year warranty against corrosion. 1.03 Release Monitoring System shall: A. Allow full visual and physical access/inspection of all piping reductions, fittings, hoses,

and equipment. B. Provide a monitor point for electronic monitoring and evacuation of fluids form both within

the sump body and for the interstitial space of the double wall. 1.04 Piping Penetrations

A. Provide locations for the installations of fluid tight double wall pipe and conduit penetration seals to be installed according to manufacturer’s instructions.

Page 3: Now in both Single Wall and Double Wall construction…A. Provide a step-up point for Stage II piping that cannot maintain full downward slope towards storage tank or tank(s). B. Prevent
Page 4: Now in both Single Wall and Double Wall construction…A. Provide a step-up point for Stage II piping that cannot maintain full downward slope towards storage tank or tank(s). B. Prevent
Page 5: Now in both Single Wall and Double Wall construction…A. Provide a step-up point for Stage II piping that cannot maintain full downward slope towards storage tank or tank(s). B. Prevent

________________________________ CCoonnttaacctt uuss ffoorr mmoorree iinnffoorrmmaattiioonn!!

1555 Copperhill Parkway • Santa Rosa, CA 95403 Ph: (800) 688-3375 or (707) 523-2050

www.westernfg.com

SSTTAAGGEE IIII VVAAPPOORR RREECCOOVVEERRYY SSUUMMPPSS

IInn bbootthh SSiinnggllee WWaallll aanndd DDoouubbllee WWaallll ccoonnssttrruuccttiioonn……

Stage II Vapor Pots from Western Fiberglass solve the problems associated with long piping runs for vapor recovery and vent lines. Vapor pots are used when sufficient piping fall or slope is not possible due to the length of a pipe run or because of site grade.

FFEEAATTUURREESS//OOPPTTIIOONNSS::

30-Year Warranty Standard 1”, 2” or 3” FRP NPT Threaded Couplings- Factory Installed Available in Standard Sizes or Custom Designs

Page 6: Now in both Single Wall and Double Wall construction…A. Provide a step-up point for Stage II piping that cannot maintain full downward slope towards storage tank or tank(s). B. Prevent

SSTTAAGGEE IIII VVAAPPOORR RREECCOOVVEERRYY SSUUMMPP ((VVAAPPOORR PPOOTT)) SSIINNGGLLEE WWAALLLL AANNDD DDOOUUBBLLEE WWAALLLL SSPPEECCIIFFIICCAATTIIOONN

CCoonnttaacctt uuss ffoorr mmoorree iinnffoorrmmaattiioonn!!

1555 Copperhill Parkway • Santa Rosa, CA 95403 Ph: (800) 688-3375 or (707) 523-2050

www.westernfg.com

Summary The Stage II Vapor Recovery sump shall provide a step up manifold system with collection tank for stage II vapor recovery piping that does not maintain positive slope towards the storage tank/s. The Stage II Vapor step up shall be constructed in single or double wall configuration and prevent the release of environmentally hazardous fluids. The Stage II Vapor Recovery Pot shall be manufactured by Western Fiberglass, Inc. System Specifications 1.01 System Suitability The Stage II Vapor Pot shall: A. Provide a step-up point for Stage II piping that cannot maintain full downward slope towards

storage tank or tank(s). B. Prevent blockage of Stage II vapor return line. C. Provide a means to remove trapped condensation from pot. D. Contain any Stage II vapor or condensation from release into the environment. 1.02 Construction Specifications: A. Meet or exceed United States National Bureau of Standards PS-15-69 for Custom Contact-

Molded Reinforced-Polyester Chemical Resistant Process Equipment. B. Be constructed of materials that are not harmful to the environment. C. Be suitable for petroleum products and blends. D. Be non-permeable to hydro-carbons and not weakened by exposure to these materials. E. Be testable. F. Have a thirty (30) year warranty against corrosion. 1.03 Release Monitoring shall: A. Allow full visual and physical inspection of draw-off piping and equipment. B. Provide, in double-wall units, a monitor point for electronic or visual monitoring of inner-wall

areas.

Page 7: Now in both Single Wall and Double Wall construction…A. Provide a step-up point for Stage II piping that cannot maintain full downward slope towards storage tank or tank(s). B. Prevent
Page 8: Now in both Single Wall and Double Wall construction…A. Provide a step-up point for Stage II piping that cannot maintain full downward slope towards storage tank or tank(s). B. Prevent
Page 9: Now in both Single Wall and Double Wall construction…A. Provide a step-up point for Stage II piping that cannot maintain full downward slope towards storage tank or tank(s). B. Prevent

________________________________ CCoonnttaacctt uuss ffoorr mmoorree iinnffoorrmmaattiioonn!!

1555 Copperhill Parkway • Santa Rosa, CA 95403 Ph: (800) 688-3375 or (707) 523-2050

www.westernfg.com

NNooww iinn bbootthh SSiinnggllee WWaallll aanndd DDoouubbllee WWaallll ccoonnssttrruuccttiioonn……

Available in multiple shapes and sizes, Western Fiberglass Transition Sumps are used for a variety of applications. Computer designed and constructed exclusively of fuel compatible materials, these rugged, practical sumps provide simple solutions in the field. Ideal as below ground piping system manifold sumps or with when installed as a transition sump for above ground tanks to below ground piping systems.

FFEEAATTUURREESS//OOPPTTIIOONNSS:: 30-Year Warranty Available in Standard Sizes or Custom Designs Multiple Lid Combinations Single Wall and Double Wall Configurations- Please add

“DW” to beginning of all part numbers required in double wall

Page 10: Now in both Single Wall and Double Wall construction…A. Provide a step-up point for Stage II piping that cannot maintain full downward slope towards storage tank or tank(s). B. Prevent

TTRRAANNSSIITTIIOONN SSUUMMPPSS

DDOOUUBBLLEE WWAALLLL SSPPEECCIIFFIICCAATTIIOONN

CCoonnttaacctt uuss ffoorr mmoorree iinnffoorrmmaattiioonn!!

1555 Copperhill Parkway • Santa Rosa, CA 95403 Ph: (800) 688-3375 or (707) 523-2050

www.westernfg.com

Summary The Double Wall Transition Sump shall provide a contained environment for piping and fittings from above ground product sources to underground systems, and as an above or below ground junction and termination box for both electrical and fluid piping and fittings. The Double Wall Transition Sump shall contain environmentally hazardous fluids that might leak from piping terminations, fittings and flex-hoses contained within the transition sump box, have full ultra-violet protection and be suitable for use in all climates and conditions. The Double Wall Transition Sump shall be manufactured by Western Fiberglass, Inc. System Specifications The Double Wall Transition Sump shall: 1.01 System Suitability: A. Be installed either above or below ground or partially buried to suit applications required. B. Be of sufficient size to allow all piping terminations, fittings, equipment, and flex-hoses to be

contained within the Transition Box. C. Allow ample area to provide for servicing and inspection of all piping terminations, fittings,

equipment and flex-hoses within the Transition Box Assembly. D. Contain any release of environmental contaminates from piping and fittings enclosed within

the Transition Box. E. Be available as a U.L. Listed device if required. 1.02 Construction Specifications: A. Meet or exceed United States National Bureau of Standards PS-15-69 for Custom Molded

Reinforced-Polyester Chemical-Resistant Process Equipment or U.L. Listing if applicable. B. Be constructed of materials that are not harmful to the environment. C. Be non-permeable by hydro-carbons and not weakened by exposure to these materials. D. Be unaffected by ultra-violet light exposure and not weakened by such exposure. E. Be suitable for petroleum products and blends. F Have a thirty (30) year warranty (Excluding Gaskets). 1.03 Release Monitoring shall: A. Allow full visual and physical access/inspection of all piping fittings and equipment.

B. Provide a monitor point for an electronic probe and/or evacuation of fluids.

Page 11: Now in both Single Wall and Double Wall construction…A. Provide a step-up point for Stage II piping that cannot maintain full downward slope towards storage tank or tank(s). B. Prevent
Page 12: Now in both Single Wall and Double Wall construction…A. Provide a step-up point for Stage II piping that cannot maintain full downward slope towards storage tank or tank(s). B. Prevent

TRANSITION SUMPSanta Rosa, Calif.

800 688-3375

Western Fiberglass Inc.

Fax 800 700-1188www.westernfg.com

FLAT SIDED WITH OPTIONAL REDUCER

STANDARD CONFIGURATION:

08-23-05 DL

TYPE AWATER TIGHT

TYPE BWATER RESISTANT

TYPE AWATER TIGHT

(OPTIONAL FLAT LID)

TYPE BWATER RESISTANT

OPTIONAL REDUCER CONFIGURATION:

TYPE TC FRICTION FIT LID

TYPE TC FRICTION FIT LID

ABCD

DIMENSION TABLE

E

ABCD

DIMENSION TABLE

E

Page 13: Now in both Single Wall and Double Wall construction…A. Provide a step-up point for Stage II piping that cannot maintain full downward slope towards storage tank or tank(s). B. Prevent

________________________________ CCoonnttaacctt uuss ffoorr mmoorree iinnffoorrmmaattiioonn!!

1555 Copperhill Parkway • Santa Rosa, CA 95403 Ph: (800) 688-3375 or (707) 523-2050

www.westernfg.com

NNooww iinn bbootthh SSiinnggllee WWaallll aanndd DDoouubbllee WWaallll ccoonnssttrruuccttiioonn……

Western Fiberglass offers both standard size octagon sumps as well as custom diameters now available in both single wall and double wall construction. Our flat-sided octagon design allows for a flat entry surface and more convenient access during installation. To ensure durability, octagon sumps are constructed of fiberglass reinforced plastic (FRP) and will maintain their form throughout the installation process. Western Fiberglass octagon sumps are compatible with all piping systems, approved by major tank manufacturers and by environmental and fire inspectors nationwide.

FFEEAATTUURREESS//OOPPTTIIOONNSS::

30-Year Warranty Available With or Without a Bottom Multiple Lid Combinations Standard or Custom Designs Single Wall and Double Wall Configurations – Please

add “DW” to beginning of all part numbers required in double wall

Page 14: Now in both Single Wall and Double Wall construction…A. Provide a step-up point for Stage II piping that cannot maintain full downward slope towards storage tank or tank(s). B. Prevent

OOCCTTAAGGOONN SSUUMMPPSS

DDOOUUBBLLEE WWAALLLL SSPPEECCIIFFIICCAATTIIOONN

CCoonnttaacctt uuss ffoorr mmoorree iinnffoorrmmaattiioonn!!

1555 Copperhill Parkway • Santa Rosa, CA 95403 Ph: (800) 688-3375 or (707) 523-2050

www.westernfg.com

Summary The Double Wall Flat Sided Sump Assembly is to be installed in conjunction with the UST (Underground Storage Tank) in accordance with the manufacturer’s installation instructions. The Double Wall Flat Sided Sump Riser and Riser Reducer shall contain environmentally hazardous fluids that might leak from any piping terminations, fittings, flex-hoses, pumps or fitting penetrations. The Double Wall Flat Sided Sump Riser Reducer Assembly shall provide a flat entry surface and an interface with the manway access cover system. The Double Wall Flat Sided Sump Riser Reducer Assembly shall be manufactured by Western Fiberglass, Inc. System Specifications 1.01 System Suitability The Double Wall Flat Sided Sump Riser Reducer Assembly shall: A. Attach to the UST manway, bung fitting or containment collar as to prevent the intrusion of

ground water into the Sump Assembly. B. Be of sufficient size to allow all piping terminations, fittings, equipment, and flex-hoses to be

contained within the Sump Assembly. C. Contain any release of environmental contaminates from the tank fittings and equipment

contained within the Sump Assembly. D. Be available as a U.L. Listed device if required. 1.02 Construction Specifications: A. Meet or exceed United States National Bureau of Standards PS 15-69 for Custom-Molded

Reinforced-Polyester Chemical-Resistant Process Equipment or U.L. Listing if applicable. B. Be constructed of materials that are not harmful to the environment. C. Be non-permeable to hydro-carbons and not weakened by exposure to these materials. D. Be suitable for petroleum products and blends including MTBE, methanol and ethyl alcohol

mixtures. E. Have a thirty (30) year warranty against corrosion. 1.03 Release Monitoring shall: A. Allow full visual and physical access/inspection of all piping reductions, fittings, hoses, and

equipment. B. Provide a monitor point for electric monitoring and evacuation of fluids. 1.04 Piping Penetrations shall: A. Provide flat surfaced locations for the installation of fluid tight pipe and conduit penetration

seals to be installed according to manufacturer’s instructions.

Page 15: Now in both Single Wall and Double Wall construction…A. Provide a step-up point for Stage II piping that cannot maintain full downward slope towards storage tank or tank(s). B. Prevent
Page 16: Now in both Single Wall and Double Wall construction…A. Provide a step-up point for Stage II piping that cannot maintain full downward slope towards storage tank or tank(s). B. Prevent

OCTAGON SUMP(42" , 48" or CUSTOM DIA. AVAILABLE)

NOTES:- ALL RISERS AVAILABLE CENTERED OR OFFSET

- OPTIONAL: WALL CONSTRUCTION SINGLE OR DOUBLE

STANDARD CONFIGURATION:FRICTION FIT LID

TYPE AWATER TIGHT

TYPE BWATER RESISTANT

MULTIPORTPHILTITE OPW CNI

08-31-05 DL

ABCD

DIMENSION TABLE

TOP VIEW:MID-SECTION

Santa Rosa, Calif.800 688-3375

Western Fiberglass Inc.

Fax 800 700-1188www.westernfg.com

Page 17: Now in both Single Wall and Double Wall construction…A. Provide a step-up point for Stage II piping that cannot maintain full downward slope towards storage tank or tank(s). B. Prevent

FFIIBBEERRGGLLAASSSS LLIIMMIITTEEDD PPRROODDUUCCTT WWAARRRRAANNTTYY

CCoonnttaacctt uuss ffoorr mmoorree iinnffoorrmmaattiioonn!!

1555 Copperhill Parkway • Santa Rosa, CA 95403 Ph: (800) 688-3375 or (707) 523-2050

www.westernfg.com

This limited warranty constitutes our only responsibility and obligation to repair and or replace materials or components. We make no other express or implied warranties or any warranty of merchantability or fitness for a particular use except for the limited conditional warranty stated below. 1. CONDITIONS OF WARRANTY This warranty applies only to materials and components manufactured by Western

Fiberglass, Inc., and is subject to notification by the original customer within (30) days of the first discovery of each cause, effect or occurrence which may cause any claim under this limited warranty, further:

A. The components manufactured by Western Fiberglass, Inc. be used only for the

purpose for which they were designed, intended, and installed, further: B. That the use of said systems and components be for the normal uses, service

conditions and installation in accordance with the manufacturer’s instructions approved by Western Fiberglass, Inc.

2. LIMITED WARRANTY Subject to the conditions herein, Western Fiberglass, Inc. warrants, for the period and

conditions below, that components manufactured by Western Fiberglass, Inc.:

A. Will conform to manufacturer’s specifications at time of sale and will be free from defects in materials and workmanship for one (1) year from date of original purchase, further:

B. Will not fail due to external corrosion for a period of thirty (30) years from the date of original purchase while remaining undisturbed in the original installation configuration, further:

C. Will not fail due to internal corrosion in any application designed and used for the containment of the materials specified upon original order for the same period, as described in paragraph B., in section 2 Above.

3. LIMITATION REMEDIES Western Fiberglass, Inc. will at its option, repair or replace the defective materials and or

components found to be defective by Western Fiberglass, Inc. in accordance with these conditions. These repairs or replacements will be furnished by Western Fiberglass, Inc. at no cost other than shipment fees hereunder. Any claims not covered by Western Fiberglass, Inc., will be the sole responsibility of the customer.

Western Fiberglass, Inc. will not be liable for any direct, incidental, special or consequential damages or other loss, including, but not limited to, damage to or loss of other property or equipment, loss of contents or service, environmental damages and or cleanup costs, loss of facilities or income, and personal injuries, whether to customers, its owners, officers, agents, employees, invitee, or otherwise, resulting from natural causes including, but not limited to, flood, fire earthquake or other act of God, negligence, willful misconduct or other cause not expressly described herein, regardless of when the same might occur.