NOTICE: SAVE THESE INSTRUCTIONS WARNING...008 Serial No. N o de série: Report #/ Raport...
Transcript of NOTICE: SAVE THESE INSTRUCTIONS WARNING...008 Serial No. N o de série: Report #/ Raport...
3-90-08422JR11_03/14
save these instructions.
installation & operating Manual
saFetY noticePlease read this entire Manual beFore You install and use Your new rooM heater. Failure to Follow instructions MaY result in ProPertY daMage, bodilY injurY, or even death.For use in the u.s. and canada. suitable For installation in Mobile hoMes.iF this harMan stove is not ProPerlY installed, a house Fire MaY result. For Your saFetY, Follow installation directions. contact local building or Fire oFFicials about restrictions and installation insPection reQuireMents in Your area.contact Your local authoritY (such as MuniciPal building dePartMent, Fire dePartMent, Fire Prevention bureau, etc.) to deterMine the need For a PerMit.cette guide d'utilisation est disPonible en Francais. chez votre concessionnaire de harMan hoMe heating.
Model(s):P38+ Freestanding Pellet Stove
NOTICE: SAVE THESE INSTRUCTIONS
hot glass will cause burns.• Donottouchglassuntilitiscooled• NEVERallowchildrentotouchglass• Keepchildrenaway• CAREFULLYSUPERVISEchildreninsameroomas
stove.• Alertchildrenandadultstohazardsofhightemperatures. high temperatures may ignite clothing or other
flammable materials.• Keepclothing,furniture,draperiesandotherflammable
materialsaway.
hot surFaces!
Glassandothersurfacesarehotduringoperationandcooldown.
WARNING!
To obtain a French translation of thismanual, pleasecontactyourdealerorvisitwww.harmanstoves.com
Pourobtenirunetraductionfrançaisedecemanuel,s’ilvous plaît contacter votre revendeur ou visitezwww.harmanstoves.com
note
Contact your local dealerwith questions on installation,operationorservice.
P38+Use&CareVideo
3-90-08422JR11_03/14 2P38+PelletStove
"PRE
VENT
HOU
SE F
IRES
"Ins
tall a
nd U
se O
nly in
Acc
orda
nce W
ith M
anufa
cture
r's In
stalla
tion a
nd O
pera
tion I
nstru
ction
s.Co
ntact
Loca
l Buil
ding o
r Fire
Offic
ials A
bout
Restr
iction
s and
Insta
llatio
n Ins
pecti
on in
Your
Are
a.
WAR
NING
: THE
STR
UCTU
RAL I
NTEG
RITY
OF
THE
MANU
FACT
URED
HOM
E FL
OOR,
WAL
L,AN
D CE
ILING
/ROO
F MU
ST B
E MA
INTA
INED
. DO
NOT
INST
ALL I
N SL
EEPI
NG R
OOM.
An ou
tside
comb
ustio
n air i
nlet m
ust b
e pro
vided
. Refe
r to M
anufa
cture
r’s in
struc
tions
and l
ocal
code
s reg
ardin
g the
requ
ireme
nts fo
r pas
sing t
he ex
haus
t ven
ting s
ystem
thro
ugh a
comb
ustib
lewa
ll or c
eiling
.
Inspe
ct an
d Clea
n Exh
aust
Venti
ng S
ystem
Fre
quen
tly.
Use a
3" or
4" di
amete
r typ
e "L"
or "P
L" ve
nting
syste
m.
Do N
ot Co
nnec
t This
Unit
to a
Chim
ney F
lue S
ervin
g Ano
ther A
pplia
nce.
FOR
USE
WIT
H W
OOD
PELL
ET F
UEL O
R UP
TO
50%
COR
N / P
ELLE
T MI
XTUR
E ON
LY.
The U
se of
Othe
r Fue
ls Ma
y Cre
ate an
Uns
afe C
ondit
ion.
Input
Ratin
g Max
: 5.5
lb. fu
el/hr.
U.S.
Elec
trical
Ratin
g: 11
5 VAC
, 60 H
z, St
art 4
.2 AM
PS, R
un 2.
8 AMP
SRo
ute P
ower
Cor
d Awa
y Fro
m Un
it.
DANG
ER: R
isk of
Elec
trical
Shoc
k. Di
scon
nect
Powe
r Befo
re S
ervic
ing U
nit.
For F
urthe
r Ins
tructi
on, R
efer T
o Own
er's
Manu
al.
Repla
ce gl
ass o
nly w
ith 5m
m ce
rami
c ava
ilable
from
your
deale
r.
Keep
View
ing an
d Ash
Rem
oval
Door
s Tigh
tly C
losed
Dur
ing O
pera
tion.
DO N
OT R
EMOV
E TH
IS LA
BEL /
NE
PAS
ENLE
VER
CETT
E ÉT
IQUE
TTE
MINI
MUM
CLEA
RANC
ES T
O CO
MBUS
TIBL
ES/
DIST
ANCE
S DE
SEC
URIT
E PA
R RA
PPOR
T AUX
MATE
RIAU
X CO
MBUS
TIBL
ES:
Back
Wall
/ Entr
e Mur
Arri
ère
2”/ 5
1mm
2”/ 5
1mm
Side
Wall
/ Entr
e Par
oi La
tér
16”/
406m
m 10
”/ 25
4mm
CORN
ER IN
STAL
LATI
ON / E
N AN
GLE
Wall
s to A
pplia
nce
9”/22
8mm
9”/22
8mm
Entre
Mur
s et a
ppar
eilFlu
e Con
necto
r/Rac
cord
à la
chem
inée
3” /
76mm
FLOO
R PR
OTEC
TION
/ Pro
tectio
n Du P
lanch
er
U
SA
Cana
daSi
des*
/Côté
s (A
) 6
” 20
0mm
Back
**/Ar
rière
(B)
6”
200m
mFr
ont*/
Avan
t (C
) 6
” 45
0mm
**Mea
sure
d fro
m pe
desta
l bas
e in t
he U
S ON
LY**M
esur
é à pa
rtir de
la ba
se du
socle
aux É
tats-U
nis un
iquem
ent
*Mea
sure
d fro
m Gl
ass O
penin
g*M
esur
er à
partir
de la
surfa
ce de
la po
rte en
verre
Floor
Pro
tectio
n Mus
t Be a
Non
-Com
busti
ble M
ateria
l.Mu
st Al
so b
e Pl
ace
Unde
r Any
Hor
izonta
l Flue
Con
necto
r, Ex
tendin
g 2” o
r 51m
m Be
yond
the P
ipe M
easu
reme
nt.Po
ur pr
otége
r le pl
anch
er, il
faut s
ous l
e pêo
le un
maté
riau.
Qui
doit a
ussi
être
placé
sous
les p
artie
s hor
izonta
les d
u tuy
au d
e ra
ccor
d à la
chem
inée
et s’é
tendr
e à 51
mm o
2 po.
au-d
elà de
la
mesu
re du
tuya
u.
Made
in U
.S.A
. of U
S an
d imp
orted
parts
. / Fa
briqu
éau
x État
s-Unis
-d’A
mériq
ue pa
r des
pièc
es d’
origi
neam
érica
ine et
pièc
es im
porté
es.
"PRE
VENT
ION
DES
INCE
NDIE
S"Re
spec
ter sc
rupu
leuse
ment
les in
struc
tions
du co
nstru
cteur
pour
l'ins
tallat
ion et
les c
onsig
nes
de fo
nctio
nnem
ent. R
espe
cter le
s règ
les de
sécu
ritè en
vigu
eur d
ans v
otre r
égion
.AV
ERTI
SSEM
ENT
POUR
MOB
ILE H
OMES
: Ne p
as in
stalle
r dan
s une
cham
bre.
ll est
impe
ratif
de pr
évoir
une p
rise d
'alr e
xtérie
ur. L'
intég
rité st
ructu
rale
du pl
anch
er, du
plafo
nd et
des m
urs d
oit ét
restr
ictem
ent p
rése
rvée.
Se re
porte
r aux
instr
uctio
ns du
fabr
icant
et au
x rég
lemen
tation
s spé
cifiqu
esloc
ales c
once
rnan
t les p
réca
ution
s req
uises
lors
de la
trav
ersé
e d'un
mur
ou d'
un pl
afond
.Co
ntróle
r et n
ettoy
er fr
éque
mmen
t tout
le sy
steme
d'ev
acua
tion d
es fu
mées
confo
rmém
ent a
uxre
comm
anda
tions
du co
nstru
cteur.
Utili
ser d
es tu
yaux
<<S
pécia
l gra
nulés
>> de
Ø76
mm
ou10
2 mm.
Ne p
as ra
ccor
der c
e poé
le à u
n con
duit d
e che
miné
e déjà
utilis
é pou
r un a
utre a
ppar
eil.
FONC
TION
NE E
XCLU
SIVE
MENT
AVEC
DES
GRA
NULE
S DE
BOI
S.Ap
pare
il de c
hauff
age à
gran
ulé ty
pe. C
onso
mmati
on m
axim
um: 2
.5 kg
/h.US
coup
ure:
115 V
AC, 6
0 Hz,
4.2 am
ps D
émar
rer, E
xécu
ter 2.
8 AMP
Sfon
ction
neme
nt no
rmal
1.1A.
Tenir
le co
rdon
d'ali
menta
tion à
l'éca
rt du
poèle
.DA
NGER
: Risq
ue d'
électr
ocuti
on. D
ébra
nche
r l'ap
pare
il ava
nt tou
te int
erve
ntion
.Ne
remp
lacer
la vi
tre qu
'avec
une v
itre cé
rami
que 5
mm de
mém
e qua
lité di
spon
ible
aupr
ès de
votre
reve
ndeu
r.Po
ur un
e info
rmati
on pl
us co
mplét
e, se
repo
rter à
la no
tice d
'utilis
ation
. Ten
ir la p
orte
herm
étiqu
emen
t clos
e dur
ant fo
nctio
nnem
ent.
Ne fa
ites p
as ob
stacle
l’esp
ace s
ous l
e réc
hauff
eur. T
oujou
rs fou
rnir u
n app
rovis
ionne
ment
suffis
ant e
n air f
rais
jusqu
’au lie
u d’in
stalla
tion A
pplia
nce
P.N. 3
-90-
0430
0
WIT
HOUT
SIDE
SHI
ELDS
WIT
HSI
DE S
HIEL
DSSa
ns É
crans
Latér
aux
Avec
Écra
nsLa
térau
x
US E
NVIR
ONME
NTAL
PRO
TECT
ION
AGEN
CYTh
is mo
del is
exem
pt fro
m EP
A ce
rtifica
tion u
nder
40 C
FR 60
.531
by de
finitio
n [W
ood H
eater
(A) "
Air-t
o-Fu
el Ra
tio"]
Agen
ce A
méric
aine p
our la
Pro
tectio
n de l
’Env
ironn
emen
tCe
mod
éle es
t disp
ensé
par E
PA ce
rtifica
tion d
’apré
s 40 C
FR 60
.531
par d
èfinit
ion [A
ppar
eil á
bois
(A) <
< Ra
tio ai
r/com
busti
ble>>
]
Date
of Ma
nufac
ture /
Date
de fa
brica
tion:
Fabr
iqué p
ar: H
earth
and H
ome T
echn
ologie
s 352
Mou
ntain
Hous
e Roa
d, Ha
lifax P
A 17
032
2013
20
14
2015
JA
N
FEB
M
AR
A
PR
MAY
JU
N
JUL
AU
G
SEP
OC
T N
OV
DEC
Har
man
PP
38+/
P43
Pel
let S
tove
Bla
ck B
ackg
roun
d w
ith b
are
met
al fo
r prin
t-adh
esiv
e ba
cked
, met
al p
late
.
BARC
ODE
LABE
L00
8Se
rial N
o.No de
série
:
Repo
rt #/
Rapo
rt #1
35-S
-21-
6.2 (P
P38+
)Re
port
#/ Ra
port
#135
-S-2
3-4,
135-
S-23
b-6.2
(P43
)Te
sted t
o / Te
sté à:
ASTM
E15
09-0
4, UL
C/OR
D-C1
482-
M199
0, UL
C-S6
27-0
0
Room
Hea
ter P
ellet
Fuel
Burn
ing Ty
pe. A
lso fo
r use
in M
obile
Hom
es.
Appa
reil d
e cha
uffag
e à gr
anulé
s de b
ois U
tilisa
ble da
ns de
s mob
ile ho
mes.
This
pelle
t bur
ning a
pplia
nce h
as be
en te
sted a
nd lis
ted fo
r use
in M
anufa
cture
d Ho
mes i
n acc
orda
nce w
ith O
AR 81
4-23
-900
thro
ugh 8
14-2
3-90
9
MO
DE
L / M
OD
ÈLE
:
"PP
38+
/
P43
"
2"(5
1mm
)
10" (
254m
m) w
ith s
ide
shie
lds
16" (
406m
m) w
/out
sid
e sh
ield
s
AA
C
B
USA
CA
NA
DA
Flo
or p
ro
tec
tor
PRO
TEC
TiO
N D
E SO
LFL
OO
R P
RO
TEC
TiO
N
9"(2
28m
m)
9"(228mm)3" min
76m
m m
in3"
min
76mm min
Rev
D
10-3
/4"
4-3/8"
The
labe
l sho
wn
here
is fo
r ref
erre
nce
only
. For
spe
cific
info
rmat
ion
on c
lear
ance
s an
d te
stin
g, c
onsu
lt th
e ac
tual
labe
l on
the
rear
of t
he P
38 fu
el h
oppe
r.
3 PP38+ Pellet Stove 3-90-08422JR11_03/14
SafetyInformation 4
Installation 6
Venting 7
ESPControl 14
Operation 15
DraftTestProcedure 18
Maintenance 19
Troubleshooting 24
Specifications 25
Options 26
Corn/PelletMixture 27
FuelSpecificationDetails 28
WiringDiagram 29
Warranty 30
ServiceParts 32
table of contents
introduction
SafetyListing:Omni-TestLaboratories,Inc.Report#135-S-21-6.2Testedto:ASTME1509-04,ULC/ORD-C1482-M1990,ULC-S627-00
Thisapplianceisalsoapprovedforinstallationintoashop.
Divisionof
Hearth&HomeTechnologies352MountainHouseRoad
Halifax,PA17032
Thislabelislocatedonthebackoftheunit.PleasecopytheSerialNumberforfuturereference.
Serial#:
"PREVENT HOUSE FIRES"Install and Use Only in Accordance With Manufacturer's Installation and Operation Instructions.Contact Local Building or Fire Officials About Restrictions and Installation Inspection in Your Area.
WARNING : THE STRUCTURAL INTEGRITY OF THE MANUFACTURED HOME FLOOR, WALL,AND CEILING/ROOF MUST BE MAINTAINED. DO NOT INSTALL IN SLEEPING ROOM.
An outside combustion air inlet must be provided. Refer to Manufacturer’s instructions and localcodes regarding the requirements for passing the exhaust venting system through a combustiblewall or ceiling.
Inspect and Clean Exhaust Venting System Frequently.Use a 3" or 4" diameter type "L" or "PL" venting system.
Do Not Connect This Unit to a Chimney Flue Serving Another Appliance.FOR USE WITH WOOD PELLET FUEL OR UP TO 50% CORN / PELLET MIXTURE ONLY.The Use of Other Fuels May Create an Unsafe Condition.
Input Rating Max: 5.5 lb. fuel/hr.
U.S. Electrical Rating: 115 VAC, 60 Hz, Start 4.2 AMPS, Run 2.8 AMPSRoute Power Cord Away From Unit.
DANGER: Risk of Electrical Shock. Disconnect Power Before Servicing Unit.
For Further Instruction, Refer To Owner's Manual.
Replace glass only with 5mm ceramic available from your dealer.
Keep Viewing and Ash Removal Doors Tightly Closed During Operation.
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ÉTIQUETTE
MINIMUM CLEARANCES TO COMBUSTIBLES/DISTANCES DE SECURITE PAR RAPPORT AUXMATERIAUX COMBUSTIBLES:
Back Wall / Entre Mur Arrière 2”/ 51mm 2”/ 51mmSide Wall / Entre Paroi Latér 16”/ 406mm 10”/ 254mmCORNER INSTALLATION / EN ANGLEWalls to Appliance 9”/228mm 9”/228mmEntre Murs et appareilFlue Connector/Raccord à la cheminée 3” /76mm
FLOOR PROTECTION / Protection Du Plancher USA CanadaSides*/Côtés (A) 6” 200mmBack**/Arrière (B) 6” 200mmFront*/Avant (C) 6” 450mm**Measured from pedestal base in the US ONLY**Mesuré à partir de la base du socle aux États-Unis uniquement*Measured from Glass Opening*Mesurer à partir de la surface de la porte en verre
Floor Protection Must Be a Non-Combustible Material.Must Also be Place Under Any Horizontal Flue Connector, Extending 2” or 51mm Beyond the Pipe Measurement.Pour protéger le plancher, il faut sous le pêole un matériau. Qui doit aussi être placé sous les parties horizontales du tuyau de raccord à la cheminée et s’étendre à 51mm o 2 po. au-delà de la mesure du tuyau.
Made in U.S.A. of US and imported parts. / Fabriquéaux États-Unis-d’Amérique par des pièces d’origineaméricaine et pièces importées.
"PREVENTION DES INCENDIES"Respecter scrupuleusement les instructions du constructeur pour l'installation et les consignesde fonctionnement. Respecter les règles de sécuritè en vigueur dans votre région.AVERTISSEMENT POUR MOBILE HOMES: Ne pas installer dans une chambre. ll est imperatifde prévoir une prise d'alr extérieur. L'intégrité structurale du plancher, du plafond et des murs doit étrestrictement préservée. Se reporter aux instructions du fabricant et aux réglementations spécifiqueslocales concernant les précautions requises lors de la traversée d'un mur ou d'un plafond.Contróler et nettoyer fréquemment tout le systeme d'evacuation des fumées conformément auxrecommandations du constructeur. Utiliser des tuyaux <<Spécial granulés>> de Ø76 mm ou102 mm. Ne pas raccorder ce poéle à un conduit de cheminée déjà utilisé pour un autre appareil.FONCTIONNE EXCLUSIVEMENT AVEC DES GRANULES DE BOIS.Appareil de chauffage à granulé type. Consommation maximum: 2.5 kg/h.US coupure: 115 VAC, 60 Hz, 4.2 amps Démarrer, Exécuter 2.8 AMPSfonctionnement normal 1.1A. Tenir le cordon d'alimentation à l'écart du poèle.DANGER: Risque d'électrocution. Débrancher l'appareil avant toute intervention.Ne remplacer la vitre qu'avec une vitre céramique 5mm de méme qualité disponibleauprès de votre revendeur.Pour une information plus compléte, se reporter à la notice d'utilisation. Tenir la portehermétiquement close durant fonctionnement.Ne faites pas obstacle l’espace sous le réchauffeur. Toujours fournir un approvisionnement suffisant en air frais jusqu’au lieu d’installation Appliance
P.N. 3-90-04300
WITHOUTSIDE SHIELDS
WITHSIDE SHIELDS
Sans ÉcransLatéraux
Avec ÉcransLatéraux
US ENVIRONMENTAL PROTECTION AGENCYThis model is exempt from EPA certification under 40 CFR 60.531
by definition [Wood Heater (A) "Air-to-Fuel Ratio"]Agence Américaine pour la Protection de l’Environnement
Ce modéle est dispensé par EPA certification d’aprés 40 CFR 60.531par dèfinition [Appareil á bois (A) << Ratio air/combustible>>]
Date of Manufacture / Date de fabrication:
Fabriqué par: Hearth and Home Technologies 352 Mountain House Road, Halifax PA 17032
2013 2014 2015 JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC
Harman PP38+/P43 Pellet StoveBlack Background with bare metal for print-adhesive backed, metal plate.
BARCODE LABEL008Serial No.No de série:
Report #/ Raport #135-S-21-6.2 (PP38+)Report #/ Raport #135-S-23-4, 135-S-23b-6.2 (P43)Tested to / Testé à:ASTM E1509-04, ULC/ORD-C1482-M1990, ULC-S627-00
Room Heater Pellet Fuel Burning Type. Also for use in Mobile Homes.Appareil de chauffage à granulés de bois Utilisable dans des mobile homes.
This pellet burning appliance has been tested and listed for use in Manufactured Homes in accordance with OAR 814-23-900 through 814-23-909
MODEL / MODÈLE: "PP38+ / P43"
2"(51mm)
10" (254mm) with side shields16" (406mm) w/out side shields
AAC
B
USA CANADA
Floor protector
PROTECTiON DE SOLFLOOR PROTECTiON
9"(228mm)
9"(228mm
)3" m
in
76mm min3" min
76mm
min
Rev D
10-3/4"
4-3/
8"
= contains updated information
WARNING!do not use cheMicals or Fluids to start the Fire. do not burn garbage or FlaMMable Fluids such as gasoline, naPtha, or oil.
WARNING!do not connect to anY air distribution duct or sYsteM.
4PP38+ Pellet Stove3-90-08422JR11_03/14
do not install a Flue daMPer in the eXhaust venting sYsteM oF this unit.
do not connect this unit to a chiMneY Flue serving another aPPliance.
Mobile hoMe installation should be done in accordance with the ManuFactured hoMe and saFetY standard (hud), cFr 3280, Part 24.
important notes
installation and rePair oF this harMan stove should be done bY a QualiFied service Person. we recoMMend that the stove be insPected beFore use and at least annuallY bY a QualiFied service Person. Periodic cleaning is reQuired throughout the heating season and at the end oF each winter For the stove to work eFFicientlY. reFer to the Maintenance section oF this Manual.
sPecial note: due to FlY ash builduP, it is stronglY recoMMended that You have Your stove ProFessionallY cleaned and serviced annuallY. this includes all Parts oF the stove, and the entire venting sYsteM.
CAUTION!do not connect to anY air distribution duct or sYsteM.
CAUTION!a chiMneY connector shall not Pass through an attic or rooF sPace, closet or other concealed sPace, a Floor, or a ceiling.
CAUTION!keeP coMbustible Materials (such as grass, leaves, etc.) at least 3 Feet awaY FroM the Flue outlet on the outside oF the building.
CAUTION!the structural integritY oF the Mobile hoMe Floor, wall, and ceiling/rooF Must be Maintained.
CAUTION!Mobile/ManuFactured hoMe standards do not allow installation in rooMs designated For sleePing.
CAUTION!do not use MakeshiFt coMPonents or other coMProMises when installing this aPPliance.
CAUTION!alwaYs be sure there is no unburned Fuel in the ash Pan Prior to lighting a Fire. this will cause sMoke and soot and other unwanted results.
5 PP38+ Pellet Stove 3-90-08422JR11_03/14
assembly and installationunpackingTheP38 isbolted(1/4x1"hexheadbolts) to theskid topreventmovementduringshipping.Tofreethestovefromtheskidyoumustremovethehold-downboltsintherearofthepedestalbase.removing rear cover panelsTherearcoverpanelsaresecuredtothestovewiththreebolts each.Twoof the bolts need only be loosened, notremoved,toremovethepanels.Itisrecommendedthattherearcoversareinstalledaftertheunitisinplaceandtheventpipeisinstalled,topreventcontactwithhotormovingparts.FirebrickInstallthesinglefirebrickhorizontallyontheanglebracketabovetheburnpot.Flame guideInstallthecastironflameguideontopoftheburnpot.Makesurethattheflameguideisfullyseatedontheverticalsidesoftheburnpotandthatthebackoftheguiderestsagainstthebodyofthestove.INSTALLEXHAUSTVENTATCLEARANCESSPECIFIEDBYTHEMANUFACTURER.Mostpelletventpiperequiresaminimumof3"ofclearancetocombustiblematerialsalthoughsomecanbeinstalledat1"clearance.Followtheseinstructionsalongwithalllocalcodesregardinginstallationofthisappliance.Do not usemakeshift compromiseswhen installing thisappliance,seriousconsequencesmayresult.Withanyhearthappliance,installationofsmokedetectorsisrecommendedoneverylevelofthehome.Possible causes of smoke detector activation:Paintcuringprocess-Openawindowneartheapplianceforthefirstfewhoursofburning.Exhaustbeingdrawnbackinsidethedwelling-Outsideairconnectiontotheapplianceisnecessary.Ventleakage-Allinteriorseamsandjointsshouldbesealedwithsiliconewhereappliacable.Followventmanufacturersinstructionsforpropersealing.
room sensor installationTheroomsensor(part#3-20-00906)isasmalltemperaturesensor on theendof a 60"wire.This sensor is installedmuch likea standardwall thermostat.Use standard18-2thermostatwiretoextendthedistancetothedesiredlocation(50'maximum).Theroomsensorshouldbeinstalledinthelocationwhereyouwanttocontrolthetemperature.NOTE:Distancesofmorethan25feet fromtheunitor inanother roomarenot recommended.The roomsensor isessentialfortheP38'sexcellentefficiency.NOTE: it is recommended that the room sensor be installed,evenifonlyinstalledontherearoftheunitasareturnairsensor.
Rear Cover Panels
Shipping Bolts Note: These same holes are used for securing the stove in mobile home installation.
Fig. 1
Route Room Sensor cable through here.
The Room Sensor cable attaches to two bare terminals on the rear of the circuit board. These connect ions are not polarity specific.
6PP38+ Pellet Stove3-90-08422JR11_03/14
installing Placethestoveonanoncombustibletypefloororfloorprotectorthatextendsaminimumof6inches(152mm)tothefrontoftheloaddooropening,6inches(152mm)tothesidesofthedooropening,and6 inches to the rear.Floorprotectionmustalsoextend2inches(51mm)beyondeachsideofanyhorizontalfluepipe.Theminimumfloorprotectormaterial is20gaugesheetmetal.Other floor protectormaterials are ceramic tile, stone,brick,etc.note for canadian installation only: PerULC-S627-00,If installed on a combustible floor, the need to provide anoncombustiblefloor protector covering theareabeneath thespace heater andextendingatleast17.72"(450mm)onthefiringsideandatleast7.87"(200mm)ontheothersides.In Canada, you may follow smaller U.S. floor protection requirements onlY if the user agrees to completely shut-down the appliance, and allow it to cool to where all fire is extinguished and the combustion blower and its indicator light shuts off, prior to opening the firebox door or ash door.PlacethestoveawayfromcombustiblewallsatleastasfarasshowninFigures3and4.Pleasenotethedifferenceinsidewallclearancewithandwithoutsideshields.Notethattheclearancesshownareminimumforsafetybutdonotleavemuchroomforaccesswhencleaningorservicing.Pleasetakethisintoaccountwhenplacingthestove.Connect the power cord to a 120 V.A.C. 60Hz groundedreceptacle. (Asurgeprotector is recommended toprotect thecircuitboard.)Alsobesurethatthepolarityoftheoutletthatthestoveispluggedintoiscorrect.Prior to installing the flue pipe, connect a draftmeter. (Thedraftmetermusthaveaminimumrangeof0-.5")Recordthefirstreading.Connectfluepipetostoveandbesurealldoorsandwindowsinthehomeareclosed.Recordtheseconddraftreading_______.Ifthesecondreadingismorethan.05"lowerthanthefirstreading,checkforpossiblerestrictionsortheneedforoutsideair(seepage10).Formoreinformationonthedrafttestprocedure,refertoPage19.Mobile home installationWheninstallingthisunitinamobilehome,severalrequirementsmustbefollowed:1.Theunitmustbeboltedtothefloor.Thiscanbedonewith1/4"
lagscrewsthroughthe2holesinthebaseplate.2.Theunitmustalsobeconnectedtooutsideair.Seepage9.3.Floorprotectionandclearancesmustbefollowedasshown.4.Unitmustbegroundedtothemetalframeofthemobilehome.caution: this appliance must be vented to the outside.Duetohightemperatures,thestoveshouldbeplacedoutoftrafficandawayfromfurnitureanddraperies.Childrenandadults shouldbealerted to thehazardsof highsurfacetemperaturesandshouldstayawaytoavoidburnstoskinand/orclothing.Youngchildrenshouldbecarefullysupervisedwhentheyareinthesameroomasthestove.Clothingandotherflammablematerialsshouldnotbeplacedonornearthisunit.
installation
l
j
Floor Protection requirements US Canada
Sides
Rear
6" 200mm
6" 200mm
k Front 6" 450mm
MinimumSizefloorprotection (USA) is321/2"wideBy33"deep(825mmX838mm).* Floor protection dimensions for the front and sidesare measured from the appliance door opening inThe United States. In Canada, the side dimension ismeasuredfromthewidestpartoftheappliance.
note:Measurement"L"ismeasuredfromthepedestalbaseintheUSONLY
note:Measurement"K"ismeasuredfromtheglassintheUSONLYwarning
the structural integritY oF the ManuFactured hoMe Floor, wall, and ceiling/rooF Must be Maintained.
do not install in sleePing rooM.
Fig. 3
9"(228mm)With or w/Out Side Shields
9"(228mm)
9"(228mm
) Alternate floor protector dimension may be used as long as they satisfy the measurement requirements shown below.M i n u m u m s i z e f l o o r protection for a corner installation hearth pad is 36" x 36". Clearance shown as 9" with optional side shields installed.
Fig. 4
2"(51mm)
36"(914mm)
10" (254mm) with side shields
16" (406mm) without side shields
10" (254mm)16" (406mm)
jusa
k
l
jcanada
Floor protector
7 PP38+ Pellet Stove 3-90-08422JR11_03/14
venting
requirements for terminating the ventingwarning:Ventingterminalsmustnotberecessedintoawallorsiding.note:Onlyapprovedpelletventpipe,wallpass-throughs,and fire stops should be used when venting throughcombustiblematerials.note:Always take into consideration the effects of theprevailingwinddirectionor otherwind currents thatmaycauseflyashand/orsmokewhenplacingtheterminationofthevent.in addition, the following must be observed:A.Theclearanceabovegrademustbeaminimumof12".B.Theclearancetoawindowordoorthatmaybeopened
must be aminimumof 48" to the side, 48" below thewindow/door, and 12" above thewindow/door. (with outside air installed, 9” to the side or below)
C.A 12" clearance to a permanently closedwindow isrecommendedtopreventcondensationonthewindow.
D.Theverticalclearancetoaventilatedsoffitlocatedabovetheterminalwithinahorizontaldistanceof2feet(60cm)fromthecenter-lineoftheterminalmustbeaminimumof18".
E.Theclearancetoanunventilatedsoffitmustbeaminimumof12".
F. Theclearancetoanoutsidecorneris11"fromcenterofpipe.
G.Theclearancetoaninsidecorneris12".H.Aventmustnotbeinstalledwithin3feet(90cm)above
agasmeter/regulatorassemblywhenmeasuredfromthehorizontalcenter-lineoftheregulator.
I. Theclearancetoserviceregulatorventoutletmustbeaminimumof6feet.
J. Theclearancetoanon-mechanicalairsupplyinlettothebuildingorthecombustionairinlettoanyotherappliancemustbeaminimumof48”.
K.Theclearancetoamechanicalairsupplyinletmustbeaminimumof10feet. (with outside air installed, 6 feet )
L. The clearance above a paved sidewalk or a paveddrivewaylocatedonpublicpropertymustbeaminimumof7feet.
M.Theclearanceunderaveranda,porch,deckorbalconymustbeaminimumof12inches. (b. also applies)
note: The clearance to vegetation and other exteriorcombustiblessuchasmulch is36”asmeasuredfromthecenteroftheoutletorcap.This36”radiuscontinuestogradeoraminimumof7feetbelowtheoutlet.CertainCanadian and/or Local codesor regulationsmayrequiredifferentclearances.Aventshallnotterminatedirectlyaboveaside-walkorpaveddrivewaywhichislocatedbetweentwosinglefamilydwellingsandservesbothdwellings.Onlypermitted ifveranda,porch,deck,orbalcony is fullyopenonaminimumof2sidesbeneaththefloor.see nFPa 211 for more installation clearance reductions when using outside air.note: where passage through a wall, or partition of combustible construction is desired, the installation shall conform to can/csa-b365. (if in canada)
V =Vent Terminal A =Air Supply Inlet =Area where termination is not permitted
Door
Sidewalk
FixedClosed
Openable
Openable FixedClosed
Inside CornerDetail
Porch orOpenable
Deck or Fixed
8PP38+ Pellet Stove3-90-08422JR11_03/14
venting
ventingA combustion blower is used to extract the combustiongasesfromthefirebox.ThiscausesanegativepressureinthefireboxandapositivepressureintheventingsystemasshowninFig.7.Thelongertheventpipeandmoreelbowsusedinthesystem,thegreatertheflowresistance.Becauseofthesefactswerecommendusingasfewelbowsaspossibleand15feetor lessofventpipe.Themaximumhorizontalrunshouldnotexceed48".Ifmorethan15feetofpipeisneeded,theinteriordiametershouldbeincreasedfrom3"to4"becausealargerpipecauseslessflowresistance.be sure to use approved pellet vent pipe wall and ceiling pass-through fittings to go through combustible walls and ceilings. all joints for connector pipe must be fastened with a minimum of three screws and a termination cap must be installed. Follow pellet vent manufacturer instructions for properly securing each pellet vent joint. the pellet starting collar must be secured to the unit's flue collar.a chiMneY connector MaY not Pass through an attic or rooF sPace, closet or siMilar concealed sPace, Floor , or ceiling. reFerence local building codes For details.
iMPortant noticeApproved3"or4"PelletVentPipeSuchAs,Type"PL",MustBeUsed.
Fig. 7
vent PipePelletventingpipe(knownasPLvent)isconstructedoftwolayerswithairspacebetweenthelayers.Thisairspaceactsasaninsulatorandreducestheoutsidesurfacetemperaturetoallowaclearancetocombustiblesof1inch.Thesectionsofpipelocktogethertoformanairtightsealinmostcases.However,insomecasesaperfectsealisnotachieved.Forthisreasonandthefactthattheunitoperateswithapositiveventpressurewe specify that the joints also be sealed with high temp (rtv) silicone. Aluminumtapecanalsobeusedforanyjointthatis1ft.ormorefromtheoutletofthestove.note: simpson duravent Pelletvent Pro harman adapter Part #3PvP-adhb and Pelletvent Pro harman adapter increaser Part #3PvP-X4adhb are highly recommended to be installed on the starter collar to insure a proper pipe connection to the unit.install vent at clearances sPeciFied bY the vent ManuFacturerdo not install a Flue daMPer in the eXhaust venting sYsteM oF this unit.do not connect this unit to a chiMneY Flue serving another aPPliance
avoiding smoke and odorsnegative Pressure, shut-down, and Power Failure:To reduce the probability of back-drafting or burn-back in the pellet burning appliance during power failure or shut-down conditions, the stove must be able to draft naturallywithoutexhaustbloweroperation.Negativepressureinthehousewillresistthisnaturaldraftifnotaccountedforinthepelletapplianceinstallation.Heatrisesinthehouseandleaksoutatupperlevels.Thisairmustbereplacedwithcoldairfromoutdoors,whichflowsinto lower levels of the house.Vents and chimneys intobasementsandlowerlevelsofthehousecanbecometheconduitforairsupply,andreverseundertheseconditions.outside air:hearth & home technologies strongly recommends attaching outside air in all installations, especially lower level and main floor locations.
do not use MakeshiFt coMProMises when installing this aPPliance. daMage and/or injurY MaY result.
CAUTION!
O+ = Positive static pressure= Negative static pressureO-
+
+
9 PP38+ Pellet Stove 3-90-08422JR11_03/14
Pernationalbuildingcodes,considerationmustbegiventocombustionairsupplytoallcombustionappliances.Failuretosupplyadequatecombustionairforallappliancedemands,mayleadtoback-draftingofthoseandotherappliances.Whentheapplianceisside-wallvented:Theairintakeisbestlocatedonthesameexteriorwallastheexhaustventoutletandlocatedloweronthewallthantheexhaustventoutlet.When theappliance is roofvented:Theair intake isbestlocatedontheexteriorwallorientedtowardstheprevailingwinddirectionduringtheheatingseason.Theoutsideairconnectionwillsupplythedemandsofthepellet appliance, but considerationmust be given to thetotalhousedemand.Housedemandmayconsumesomeairneededforthestove,especiallyduringapowerfailure.Itmaybenecessarytoaddadditionalventilationtothespaceinwhichthepelletapplianceislocated.ConsultwithyourlocalHVACprofessionaltodeterminetheventilationdemandsforyourhouse.Toinstalloutsideairuse3"non-combustibleflexpipe.Thereisabreak-awayholeontherearpanelofthestovewhichmustberemovedbeforeconnectingtheflexpipe.Thepipeshouldberunoutsideandterminatetothesideorbelowtheventpipeoutletsotheflueoutletismorethan12"fromtheinletcover.Themaximumlengthrunofthispipeis15feet.Inletcover,partnumber1-10-09542shouldbeusedtokeepbirds,rodents,etc.outofthepipe.Youmay choose to use the optional Direct VentWallPassthroughKit(part#1-00-677177)whichincorporatestheventingpassthroughandoutsideairinletintoonecomponent.
venting
Outside air flex pipe goes here.
Inlet Cover part# 1-10-09542
Direct Vent Wall Passthrough Kit (part #1-00-677177)
Vent Configurations:Toreduceprobabilityofreversedraftingduringshut-downconditions,Hearth&HomeTechnologiesstronglyrecommends:• Installingthepelletventwithaminimumverticalrunoffivefeet,preferablyterminatingabovetheroofline.• Installingtheoutsideairintakeatleastfourfeetbelowtheventtermination.Topreventsootdamagetoexteriorwallsofthehouseandtopreventre-entryofsootorashintothehouse:• Maintainspecifiedclearancestowindows,doors,andairinlets,includingairconditioners.• Ventsshouldnotbeplacedbelowventilatedsoffits.Runtheventabovetheroof.• Avoidventingintoalcovelocations.• Ventsshouldnotterminateunderoverhangs,decksorontocoveredporches.• Maintainminimumclearanceof12inchesfromtheventterminationtotheexteriorwall.Ifyouseedepositsdeveloping
onthewall,youmayneedtoextendthisdistancetoaccommodateyourinstallationconditions.hearth & home technologies assumes no responsibility for, nor does the warranty extend to, smoke damage caused by reverse drafting of pellet appliances under shut-down or power failure conditions.
10PP38+ Pellet Stove3-90-08422JR11_03/14
#2 Preferred method Thismethod also provides excellent venting for normaloperationbutrequiresthestovetobeinstalledfartherfromthewall.Theverticalportionoftheventshouldbethreetofivefeethighandatleastthreeinchesfromacombustiblewall.Thisverticalsectionwillprovidenaturaldraftintheeventofapowerfailure.If the stove is installed below grade be sure the venttermination is at least 12" above grade. The outlet must also be 1 foot from the house/building. Note: Do not place joints within wall pass-throughs.
#1 Preferred method Thismethodprovidesexcellentventingfornormaloperationandallowsthestovetobeinstalledclosesttothewall.Twoinches from thewall is safe; however, four inchesallowsbetteraccesstoremovetherearpanel.Theverticalportionoftheventshouldbethreetofivefeethigh.Thisverticalsectionwillhelpprovidenaturaldraftintheeventofapowerfailure.note: do not place joints within wall pass-throughs.
venting
Fig. 8
Fig. 9
CAUTION!keep combustible materials (such as grass, leaves, etc.) at least 3 feet away from the flue outlet on the outside of the building.
3 Ft.to
Combustibles
3 Ft.to Combustibles
3 Ft.to
combustibles
3 Ft.to combustibles
11 PP38+ Pellet Stove 3-90-08422JR11_03/14
#4 installing into an existing chimney Thismethodprovidesexcellentventingfornormaloperation.Thismethodalsoprovidesnatural draft in theevent of apowerfailure.Ifthechimneyconditionisquestionable*youmaywanttoinstallalinerasinmethod#7.InsomeplacesintheUSandCanadaitisrequiredthattheventpipeextendallthewaytothetopofthechimney.*The chimney should be inspected and cleaned beforeinstallingyourstove.Ifyoudiscoverthatthechimneydoesnothaveaclaytilelinerorhascracksorflakingofthetileliner youwill need to install a stainless steel linerwithinthechimney.Inmostcasestheinsidediameterofthislinershouldbe4".Eitherflexibleorrigidlinermaybeusedforthispurpose.RefertoMethod6&7.Besuretodesigntheventingsothatitcanbeeasilycleaned.
#5 Installing into an existing fireplace chimney Thismethodprovidesexcellentventingfornormaloperation.Thismethodalsoprovidesnatural draft in theevent of apowerfailure.Ifthechimneyconditionisquestionable*youmaywanttoinstallalinerasinmethod#6.InsomeplacesintheUSandCanadaitisrequiredthattheventpipeextendallthewaytothetopofthechimney.*The chimney should be inspected and cleaned beforeinstallingyourstove.Ifyoudiscoverthatthechimneydoesnothaveaclaytilelinerorhascracksorflakingofthetileliner youwill need to install a stainless steel linerwithinthechimney.Inmostcasestheinsidediameterofthislinershouldbe4".Eitherflexibleorrigidlinermaybeusedforthispurpose.RefertoMethod6&7.The chimney should be sealed at the damper using asteel plate.Kaowool,mineralwool or an equivalent non-combustibleinsulationisrecommendedtobeinstalledontopofthesealingplatetoreducethepossibilityofcondensation.The connector pipe should extend through the smokechambertothebaseorintothefirstfluetile.Besuretodesigntheventingsothatitcanbeeasilycleaned.
Fig. 10
Fig. 11
venting
12PP38+ Pellet Stove3-90-08422JR11_03/14
#6 Installing into an existing fireplace chimney Thismethodprovidesexcellentventingfornormaloperation.Thismethodalsoprovidesnatural draft in theevent of apowerfailure.InsomeplacesintheUSandCanadaitisrequiredthattheventpipeextendallthewaytothetopofthechimney.Thepipeorlinerinsidethechimneyshouldbe4"diameter.Inthismethodacapshouldalsobeinstalledonthechimneytokeepoutrain.Besuretouseapprovedpelletventpipefittings.Sealpipe jointswithsiliconeoraluminum tape inadditiontothesealingsystemusedbythemanufacturer.Pipesizeshouldbeincreasedto4"usingthismethod.
#7 installing into an existing chimney Thismethodprovidesexcellentventingfornormaloperation.Thismethodalsoprovidesnatural draft in theevent of apowerfailure.InsomeplacesintheUSandCanadaitisrequiredthattheventpipeextendallthewaytothetopofthechimney.Thepipeorlinerinsidethechimneyshouldbe4"diameter.Inthismethodacapshouldalsobeinstalledonthechimneytokeepoutrain.
venting
Fig. 12
Fig. 13
13 PP38+ Pellet Stove 3-90-08422JR11_03/14
12"min. wall to outlet
36"
min. clearance to any
combustible material
12"
min
. abo
ve g
roun
d le
vel
PL vent manufacturer's �restop spacer and support
1" MIN.
No insulation or othercombustible materialsare allowed within 3"of the PL vent pipe.
�ashing
storm collar
1" MIN.
1" MIN.
12" M
IN
1” MIN.
#8 installing through the ceilingThrough the ceiling vent, followPL ventmanufacturersrecommendationswhenusingwallandceilingpassthrough. note: do not place joints within wall pass-throughs.
Fig. 14
venting
Fig. 15
Fig. 16
Minimum flue vent configurationIt is recommended that outsideair be installed with this ventingconfiguration.
Area within dotted circle represents the minimumclearance to combustiblematerials suchasshrubbery,mulchortallgrasses.
14PP38+ Pellet Stove3-90-08422JR11_03/14
esP control
status light error Messages3-blinks: IndicatesthattheESPhasgoneoutofrangetoomanytimes.Couldbeanindicatorofbuildupofash,etc.inthefluepipeorheatexchange.PerformaManualReset.4-blinks: Indicates that the room sensor circuit is notcomplete. May mean a poor connection or short in thesensorwire.(Willonlyoccurin"RoomTemp"mode.)
Feed adjusterSets the maximum feed rate
TestRuns all motors at full speed for one minute to check operat ion. Afterwards, the control will simulate a minimum burn and the combustion blower will remain on low for draft test convenience.
Distribution Blower s p e e d a d j u s t m e n t range. L = lowH = highVariable speed anywhere b e t w e e n L a n d H ; although as the stove temp. goes up, so does the low end of the scale.
Temperature Dial;Allows you to adjust the room temperature in Room Temp Mode using the outer scale marked in degrees Fahrenheit. It also allows you to adjust the stove temperature while in Stove Temp Mode using the inner scale marked from 1 to 7.
Mode Selector Allows you to choose between Room Temp Mode, Stove Temp Mode, or OFF. Also allows you to vary the distribution blower speed by turning the knob to the high or low side of each mode.
Power LightIndicates power to the control.
Indicates power to the feed motor.
Indicates power to the combustion blower
Status LightWill be lit in either stove or room temp mode when pointer is not within off position band except after normal shut down. Blinks to indicate errors listed below.
Indicates power to the distribution blower.
Dealer Diagnostic PortFor dealer maintenance only. Requires special DDM monitor supplied to Harman Dealers exclusively.
6-blinks: Indicates the control hasmeasured incompletecombustionocurring formore than25minutes.Thiserrormay be set if the feed system runs out of fuel. Turn thecontrolto"OFF"andbacktothedesiredmodetoresumeoperation.Ifthelackoffuelwasnotthecause,refertothetroubleshootingsection.Manual reset: Turn the mode selector to "OFF", anddisconnectpowerforasecond.Restorepowerandreturntooriginalsetting.
15 PP38+ Pellet Stove 3-90-08422JR11_03/14
operation
TheP38+featurestwooperatingmodes;stove temperature Modeandroom temperature Mode.InStoveTemperatureMode,youselectaburnrateandthestovewillremainatthesameburnrateregardlessoftheroomtemperature.IntheRoomTemperatureMode,withtheoptionalroomsensorattached,thestoveconstantlymonitorsthetemperatureintheroomandadjuststhesizeofthefireandtheheatoutputofthestovesothattheroomiskeptataconstanttemperature.room temperature Mode Mostconsumersuse thestove in theRoomTemperatureModebecause it is theeasiestandmostefficientmethodofkeepingtheroomatagiventemperature. In theRoomTemperatureMode, theRoomSensingProbe constantlymonitorsroomtemperature.Astheweatherchangesoutsideandyourhomeneedsvaryingamountsofheat tobeatadesired temperature, thestovewillautomatically increasefiresizeandheatoutputsothataconstanteventemperatureismaintained. If theweatherwarms up and no heat isrequired,thestovewillgraduallyslowdownandholdattheminimumburnrate.Whenthehousecoolsdown,thestovewillautomaticallybringtheroomtemperaturetotheprecisetemperatureyoudesire.IntheRoomTemperatureMode,thedistributionblowerspeedcanbeincreasedordecreasedbyadjustingtheRoomTemp/Off/StoveTempdialbetweenLandH.Asoutputofthestoveincreases,thespeedoftheblowerwillincreaseautomaticallytoinsurethatmoreheatistransferredintotheroom.
room temperature Mode: This setting, see above,will produce a room temperature of 70 degreeswith thedistributionbloweratmediumspeed.
CAUTION!do not use cheMicals or Fluids to start the Fire. For eXaMPle: never use gasoline, gasoline-tYPe lantern Fuel, kerosene, charcoal lighter Fluid, or siMilar liQuids to start or "Freshen uP" a Fire in this heater. keeP all such liQuids well awaY FroM the heater while it is in use.
CAUTION!do not connect to anY air distribution duct or sYsteM. do not burn garbage or FlaMMable Fluids such as gasoline, naPtha, or engine oil.
hot while in oPeration. keeP children, clothing, and Furniture awaY. contact MaY cause skin burns.
keeP FireboX and ash reMoval doors closed during oPeration. Maintain seals in good condition.
room temperature Mode
16PP38+ Pellet Stove3-90-08422JR11_03/14
operation
The setting above will produce continuous maximum heat output with the distribution blower at full speed.
stove temperature Mode
The setting above will produce continuous medium heat output with the distribution blower at low speed.
stove temperature ModeIntheStoveTemperatureMode,thestovecanbeadjustedtothedesiredsettingusingthesametemperaturecontroldialasisusedintheRoomTemperatureMode.Theheatoutputandfuelconsumptionwillremainconstantregardlessofroomtemperature.Thesettingsfrom1to7ontheinnerringofthetemperaturedialprovideforrelativeheatoutputsettingswith1beinglowand7beingthemaximum.Neverpulltheplugtoshutdownthestove.Thiswillstopthecombustionblowerandsmokewillescapethroughwindowanddoorgaskets.Feed adjuster knobFormostpremiumgradepelletfuelstheFeedAdjusterKnobshouldbesetat4.Ifhigherashfuelsareusedthesettingshould be increased to 5 or 6.Also higher settings arerequiredifyouwouldliketogetthemaximumheatoutputfromthestove.Atthemaximumburnrate(withthetemperaturedialon7/90°andthefeedadjusterat6)thereshouldbe1"ormoreofashonthefrontoftheburnpot.Ifthereislessthan1"ofash,turnthefeedadjusterknobdowntoalowersetting.shut down ProcedureThe bestway to shut down the stove is to simply let itrunoutofpellets.Thestovewillshutdownautomatically.Alternatively,youcanturntheModeSelectorto“off”.Thiswillcausethefiretograduallydiedownandgoout.Thefirewillnotgooutimmediatelyandmaytakemorethananhourtofullyshutdown,dependingontheburnrate.Ifthestoveislefttorunoutoffuel,youmaygeta6blinkstatuslight.Ifthishappens,simplyresetthecontrolboardbyturningthemodeselectortoOFFandbackON.
CAUTION!hot while in oPeration. keeP children, clothing, and Furniture awaY. contact MaY cause skin burns.
17 PP38+ Pellet Stove 3-90-08422JR11_03/14
starting First FireMakesuretheunitispluggedintoa100VAC,50Hzelectricalsource.Thepowerlightshouldbetheonlylightlit.
operation
1. Fines are small pieces of broken pellets (sawdust). Fines do not flow easily and often build up on the hopper funnel bottom angles. You can push these fines into the feeder opening and then fill the hopper with pellets. As the system works, they will be burned. Or you can clean them out before filling the hopper.
2. The "TEST" cycle will operate the feeder motor for exactly one minute. Turning to "TEST" again and again may load too much fuel into the burn pot causing excessive smoke on start-up.
3. The firebox low pressure switch will not allow the auger motor to operate if the view door or the ash pan door are open.
4. Adjust Feed Rate. If this is your first fire or you are trying different pellets, set the feed adjuster to #4, Fig. 17. This is a conservative number and will probably need to be increased. After you know a feed rate setting that works well, use that setting. Remember, if your feed rate is too high you may waste fuel.
5. This is usually a weekly maintenance procedure. Cleaning the burn pot with the scraper with a small amount of new fuel in the bottom is not a problem. First, scrape the ashes off the front of the burn pot into the ash pan. Then, scrape the top surface of the burn pot downward into the base of the burn pot. When the stove is ignited these scrapings will be pushed out by the feeder and burned.
6. The ash pan can hold the ashes from approximately 1 ton of premium fuel. This means the ashes will only need to be emptied a few times a year.
7. Allow the unit to burn for about 30 minutes and check ash on front of burn pot. Fig. 18. If the ash line is larger than 1", turn the feed adjuster from #4 to #5. Allow another 30 minutes of burn time and check again. If , at #6 setting, a 1" or less ash bed is not obtainable, it is not a problem. The 1" ash bed is only a maximum burn rate and at most normal settings the ash bed will be larger.
Fig. 17
notice: be sure there is no unburned fuel or other combustibles in the ash pan prior to lighting.
1. turn Feed adjuster to desired feed rate.No.4isgoodformostpellets.
2. turn the Mode selector to “oFF” and then to the desired mode.Thiswill resetcontrolandstart thecombustionmotor.
3. turn the teMPerature dial to the desired setting.4. clean burn pot with scraper if necessary.5. Fill burn pot with pellets, only level with front edge.
(DoNotOverFill).6. add starting gel on top of the pellets.Stirgelintopellets
forfastlighting.7. light starting gel with a match, and close the door.
Operationwill beginwhen the fire reaches the propertemperature.
8. Fill hopper with pellets and remove ashes as required.keeP the aPPliance doors and hoPPer lid closed during oPeration.
Fig. 18
STARTER GEL
See Hint #71"
18PP38+ Pellet Stove3-90-08422JR11_03/14
Asimple draft test should beperformedbefore andaftercompletingthefluepipeinstallation.Tocompareandtorecordtheresultsforfuturereference:1.Plugtheunitintoa100VAC,50Hzoutlet.2.Closethehopper lid, frontviewdoor,andtheashpan.
Neitherpelletsorafirearerequiredforthistest.3.Withthemodeselectorinthe"OFF"position,turnthefeed
adjusterto"TEST".4.Record thehighdraft______inW.C. (Normal is -.50 to
-.60)ThecontrolwillbeontheHighDraftforaminute.5.After1minute,thecombustionmotorwillgodowntolow
draft and thedistributionblowerwill goonhigh.Allowapproximately 15 seconds to pass for the combustionmotortoslowbeforecheckingthelowdraft.
6.Ifthelowdraftisbetween-.25and-.35,recordthereading_____inW.C.
If thereading is lower,checkforresistance in theventingconfiguration.Toomanyelbows,orexcessivehorizontalrunswilladdresistance.Also,besurethedoorsandhopperlidareproperlysecured.As longas thedraft reading dropswhen the combustionblowergoestolowspeed,higherreadingsarenotanissue.Longverticalrunscanactuallyincreasethereadingsduetotheadditionofnaturaldraft.Ifthedraftreadingdoesnotdrop,thereislikelyrestrictionontheairintake.Besuretheintakeflapperisopeningandcheckforresistanceintheoutsideairconduitifinstalled.
draft test Procedure
Fig. 23
Draft Meter bolt hole locationOn a PP38 the draft test hole is under the left rear corner of the firebox.
19 PP38+ Pellet Stove 3-90-08422JR11_03/14
MaintenanceMinimizing creosote:Wheneverwoodisburnedslowly,thepotentialexistsforcreosotetoformintheventing.Thechimneyorventingsystemshouldbeinspectedperiodicallythroughouttheheatingseasontodetermineifacreosotebuilduphasoccurred.Ifasignificantlayerofcreosotehasaccumulated(3mmormore),itshouldberemovedtoreducetheriskofachimneyfire.Aprofessionalchimneysweepisrecommended,sincetheywouldnormallyhavethecorrectequipmenttoensurepropercreosoteremoval.
If you experience a fire in the venting system,turnthestoveto"OFF"toallowtheunittoshutdown.Callthefiredepartment,andbesureeveryoneisoutoftheresidence.Beforere-usingtheappliance,haveit,andtheventingsystemthoroughlyinspectedandreplaceanydamagedcomponents.
The glass in your Harman stove is a special 5mmceramicglass.• Donotabusetheglassbystrikingorslammingthe
door.• Neverburntheapplianceifthedoorglassiscracked
orbroken.• ReplaceonlywithHarmansuppliedglass.DoNOT
UseSubstitutes.Soot and/or fly-ash may accumulate on the viewingglass,andwillocassionallyneed tobecleaned.Cleantheglasswithasoftclothandmildglasscleaner.Donotcleantheglasswhenhot,andavoidtheuseofabrasivecleaners.
GlassreplacementCarefully remove all remaining glass and gasketmaterialspriortoreplacingtheglass.
Lay thedoor facedownonaflatsurface.Remove theglass retainers and screws.Apply the gasketmaterialto the face of the new glass. Lay the glass into thedoor,makingsurethattheglassiscontainedwithinthechannelsandraisedareasofthedooritself.Laytheglassretainersintopositionandinstallthescrews.Tighteneachscrewevenlytoavoidmakinganystresspoints.
RetainersandscrewsGlass
Adhesivegasket
DoorFrame
insPect aPPliance and coMPonents For daMage. daMaged Parts MaY iMPair saFe oPeration.• do not install daMaged
coMPonents.• do not install incoMPlete
coMPonents.• do not install substitute
coMPonents.rePort daMaged Parts to dealer.
Fire risk.hearth & hoMe technologies disclaiMs anY resPonsibilitY For, and the warrantY will be voided bY, the Following actions:
• installation and use oF anY daMaged aPPliance.
• ModiFication oF the aPPliance.• installation other than as instructed bY
hearth & hoMe technologies.• installation oF Parts or coMPonents not
suPPlied or aPProved bY hearth & hoMe technologies.
• oPerating aPPliance without FullY asseMbling all coMPonents.
or anY such action that MaY cause a Fire hazard.
WARNING! WARNING!
20PP38+ Pellet Stove3-90-08422JR11_03/14
Maintenancescraping the burn pot:Whenever adding fuel to the hopper, take the time andscrapethegratesurfaceoftheburnpot,usingthescrapertoolprovided.Thiscanbedonewhileafireisburning.Wearingheatresistantgloves,openthefireboxdoor.Scrapeanyaccumulatedashesfrominfrontofthefire,intotheashpan.Now,scrapeunderthefire,inadownwarddirection,toloosenanycarbondeposits.Donotscrapethefireoutofthepot.Whateveryouloosenwillbepushedoutwiththeflowofnewfuelintothepot.removing ashes:Afterapproximately1tonofpelletshasbeenburned,itwillbenecessarytoemptytheashpan.disposal of ashes- ashes should be placed in a steel container with a tight fitting lid. The closed container of ashes should be moved outdoors immediately and placed on a noncombustible floor or on the ground, well away from all combustible materials, pending final disposal. if the ashes are disposed of by burial in soil or otherwise locally dispersed, they should be retained in the closed container until all cinders have been thoroughly cooled. other waste shall not be placed in this container.cleaning:Itisrecommendedthatthestoveiscoldandshutdownwhenremovingtheashpan.1.Lift the latchhandle toopen theashdoorand remove
theashpan.Useashpanhandletocarryanddisposeofashes.
2.Slidetheashpanbackintothestoveandlatchthedoorbypushingdownonthelatchhandlewhenclosed.
cleaning:Thestoveshouldbeshut-downandthoroughlycleanedaftereach tonofpelletsconsumed.Thecleaner thestove, themoreefficientitwillbe.note: Fuelwith higher ash and/ormoisture contentwillrequiremorefrequentcleanings.1.Shut down the stove anddisconnect power cord to
insurethatallmotorsarestopped.2.Cleanheatexchangerwithscraperasshowninfig27.3.Brushorscrapetheinsideofthestovetoremoveflyash.4.Scrapeburnpotwithflatendofscraperprovidedwiththe
stove.Inspecttheholesontheburnpotsurface.SeeFig.33.
5.Openburnpotclean-out.Cleanflyashfromburnpotandreplacecover.
Combustion Blower Cover
Blower Cover Latch
Fig 26
Scraper
Blower Cover Latch
Blower Wheel
Flue Outlet
Heat Exchanger Fins
Fig 27
21 PP38+ Pellet Stove 3-90-08422JR11_03/14
Maintenance6.Removetheashpanandproperlydisposeoftheashes.7.Removecombustionblowercoverbyturningtheblower
coverlatchvertical,seeFig.26.Slidingthecoveroutoftheslotontheleft.Thiswillexposethecombustionblowerwheelandflueoutlet,Fig.27.
8.Cleanthecombustionblowerwheelwithabrushandavacuumcleaner.Note:Donotuseahouseholdvacuumtocleanthestove.Werecommendthatyouuseashopvacuumthat isequippedwithafinedustfiltercalledaHEPAfilteroravacuumspeciallymade forashesandsoot.using a vacuum which is not equipped with a fine dust filter may clog and disperse fly ash and soot into the room.
note: the stove Must be coMPletelY out beFore You vacuuM the stove. live Pellets, iF sucked into the vacuuM will light the vacuuM on Fire and MaY ultiMatelY cause a house Fire.9.Useabrushtocleantheflue,beingcarefulnottodamage
theESP,seeFig.30.Thefluegoesstraightthroughintotheventpipe(Fig.27)therefore,theventpipecanalsobecleaned,tosomeextent,throughtheflueoutlet.
10.Reinstalltheblowercoverandclosethelatch.11. Slidetheashpanintostoveandlatchthedoor.soot and Fly ashFormation and need for removal - The products ofcombustionwillcontainsmallparticlesofflyash.Theflyashwillcollectintheexhaustventingsystemandrestricttheflowofthefluegases.Incompletecombustion,suchasoccursduringstartup,shutdown,orincorrectoperationoftheroomheaterwillleadtosomesootformationwhichwillcollectintheexhaustventingsystem.the exhaust venting system should be inspected at least once every year to determine if cleaning is necessary.Removingflyashandsootimprovesefficiencyandinsuresthattheflueventingpassagewayisclearandunobstructed.Thestoveshouldbecleanedaftereachtonofpellets(50bags)andtheventingsysteminspectedandcleanedaftereachheatingseason.
Exposedblowerwheelandflueopening,NOTE:ESPisvisible.
ESP
Fig. 30
Burn pot Clean-out plate
Latch "open "with blowercoverpartlyremoved.Burnpotclean-outisopen.
Latch"closed"withblowercover in place. Burn potclean-outisclosed.
Blowercoverremoved.
Fig. 29Fig. 28
Fig. 31
ESP
Be careful not to damage the ESP when cleaning with brush.
22PP38+ Pellet Stove3-90-08422JR11_03/14
burn Pot cleaning and Maintenance1. Scrapethetopholedsurfaceandsidesoftheburnpot.
(Fig 33) It is not necessary to completely remove allmaterialfromtheburnpot.Theexcesswillbepushedoutduringthenextuse.
2. Loosenthe(2)wingthumbscrewsonthelowerfrontangleoftheburnpot.(Fig.34)
3. Liftofftheclean-outcovertoopenthebottomclean-outchamber.
4. Cleanashbuildupfrominsidethechamberwhilecoverisoff.Usethescrapertotaponthetopfrontedgeoftheburnpot.Thiswillhelpknockpiecesofash,loosenedbythescrapingprocess,downthroughtheholes.
5. Besurethecover is inplaceonthescrewsandhand-tightenthewingscrews.
Maintenance - burn Pot
Fig. 34
dANGeR!disconnect the power to the unit before removing cover.
Fig. 33
Wing Thumb Screws
23 PP38+ Pellet Stove 3-90-08422JR11_03/14
Maintenance - cleaning the Feeder bodyPelletfinesmayaccumulateinthefeederbodyoveraperiodoftime;therefore,ayearly inspectionandcleaningofthisareamustbeperformed.Tocleanoutfines:1. Removetherearcoverpanels.2. Removewingnutand feeder coveron thesideof the
feeder.3. Useavacuumcleanertoremoveallfines.4. Reinstallfeedcover,wingnut,andrearcoverpanels.
5/16" Hex Head Screws (2 on each side)
5/16" Hex Head Screws (2 on each side)
safety FeaturesThelowdraftsensorwhichisavacuumdifferentialswitch,monitorsthenegativepressure(draft)inthefireboxthroughaportontherearofthefeeder.Poordraftwillresultinaninterruptionofpowertothefeedermotor.Poordraftcanbecausedbyblockageintheexhaust,excessivebuild-uponthecombustionblowerfanblades,afailedcombustionblower,oradoororotheropeningtothefireboxnotsealedproperly.Thecircuitboardismonitoringthepositionofthisswitch.Duringafeedcycle,ifthisswitchweretoopen,thefeedmotorlightonthecontrolwillstayilluminatedwiththepowerbeinginterruptedbytheswitch.Iftheswitchopenswhenthecycleisatrest,thepowerlightforthefeedmotorwillnotilluminate.Besurealldoors,includingthehopperlid,aresecurelyclosedwhenoperatingtheappliance.
Pellet Fines may build up in this area
Low Draft Sensor
Air Intake Flapper
24PP38+ Pellet Stove3-90-08422JR11_03/14
sMoke is visible coMing out oF vent1. Air-fuelratioistoorich.
a.Feedratetoohigh.b.Drafttoolowcausedbyagasketleak.
low heat outPut1.Feedratetoolow2.Drafttoolowbecauseofgasketleak.3.Poorqualityordamppellets4.Combinationof1and2.
trouble-shooting
helpful hintscleaning burn PotWheneveryourstoveisnotburning,taketheopportunitytoscrape theburnpot to removecarbonbuildup.Avacuumcleanerishandytoremovetheresidue.be sure the stove is cold if you use a vacuum.Carbonbuildupcanbescrapedloosewiththefireburningusingthespecialtoolprovidedwithyourstove.Scrapethefloorandsidesoftheburnpot.Thecarbonwillbepushedoutbytheincomingfuel.Alwayswearglovestodothis.removing ashesTurntheTempDialtonumber1approximately30minutesbeforeremovingashes.Thiswillresultinacoolerstoveandashpan.MaximumFeedAdjuster settingsarenot needed inmostcases.Operatinginthenormalrange(#4)isrecommendedwhenmaximumheatoutputisnotrequired.TheESPcontrolpreventsthestovefrombeingover-fired.Keepthestovefreeofdustanddirt.
stove does not Feed1. Nofuelinhopper.2. Fireboxdraftmaybetoolowforsensingswitchinfeeder
circuit to operate.check for closed doors, loose ormissinggasketondoorsorhopperlid.
3. Feedmotorwillnotrununtil theESPcontrolsensesacertaintemperature.Maybeyoudidnotputenoughfuelorstartinggelintheburnpotbeforemanuallylightingthefire.
4. Restrictioninthehopperorfeeder.Removeallfuelandexamine.Cleartheobstruction.
5. Feedmotorhasfailed.PartiallY burned Pellets1. Feedratetoohigh.2. Poorairtofuelmixture.(Checkburnpotclean-outcover
andairintake).3. Burnpotorheatexchangertubesmayneedtobecleaned.4. Combinationofalltheabove.5. #6 status blink:A6blinkcontrolboardstatusindication
iscausedbypoororincompletecombustion.ThecircuitboardhastheabilitytotrackthecombustionthroughfeedsettingsandESPtemperatures.Whenthecontrolboardhascalculatedpoororincompletecombustion,itwillshutdown theunitasasafety feature. (Pooror incompletecombustionisacontributorofcreosotewhichmaycauseachimneyfire)
a 6 blink status may be caused by several things:1. Blockedorpartiallyblockedflue.2. Blockedorpartiallyblockedinletair.
a.Backdraftdamperontheinletpipemaybestuckclosed.b.Ifoutsideairisinstalled,theinletcovermaybeblocked.
3. Theairchamberundertheburnpotmaybefilledwithfinesandsmallbitsofash.
4. Theholesintheburnpotmaybegettingfilledwithashorcarbonbuildup.
5. Combustionblowerfanbladesmayneedcleaned.6. Fuelrestrictionsasnotedabove.sMoke sMellSealtheventpipejointsandconnectiontostovewithsilicone.Theexhaustventistheonlypartofthesystemthatisunderpositivepressure.Fire has gone out- check for status light.1. Nofuelinhopper.2. Draftistoolow,blockedflue.3. Somethingisrestrictingfuelflow.4. Hopperlidnotclosedproperly.5. Feedmotororcombustionblowerhasfailed.
FuelPelletfuelsareputinto3categoriesintermsofashcontent.Premiumat1%orless,Standardat3%orlessandallothersat3%ormore.TheP38+iscapableofburningall3categoriesofpelletsduetoapatentedfeederandburnpotsystem.Itshouldbenoted,however, thathigherashcontent,andwhenmixingwith corn, will requiremore frequent ashremoval, scraping of the burn pot, andmayprovide lessBTU'sperpound.Normally,standardandhighashpelletscost less thanpremiumpellets and canbe cost effectivewhenburnedintheP38+.Themoisturecontentofpelletsmustnotexceed8%,andcorn15%.HighermoisturewillrobBTU'sandmaynotburnproperly. Fuel shouldnot be storedwithin the stove installationclearancesorwithinthespacerequiredforchargingandashremoval.SeePage7.
25 PP38+ Pellet Stove 3-90-08422JR11_03/14
Specifications
weight 212 lbs.blower 135 cfmFeed rate approximate .75lb. to 5.5 lbs per hrhopper capacity 50 lbsFuel wood PelletsFlue size 3 inchoutside air size 3 inchFuse rating 6 amp
22”
5 1/16"
13 3
/4"
10 1
/4"
33 1
/8"
28 5
/16"
26PP38+ Pellet Stove3-90-08422JR11_03/14
optionsside heat shields -Part#1-00-773863Sideheatshieldsareavailabletoreducetheclearancetocombustiblematerials.
hopper extension -Part#1-00-08536Thehopper extension allows you to putmore pellet fuelinthehopperwhichextendstheburntimeononeloadofpellets.Thehopperextensionadds60poundstotheexistinghoppercapacity,allowingyoutoload120poundsofpelletsatonetime.Theextensionsealstotheunithopperwiththreelatches.Somemodelswillrequireaknockoutberemovedfromtheunithopperpriortoinstallingtheextension.
decorative tile/grey slate optionsTheslatetilesmeasure11.938"x5.938".Thetileframe(partoftrimkit)isnecessarytoholdtheslateinplaceonthestove.Thereare4decorativeslatechoices.Seedealerforsamples.TheBrushedStainlessdeercutout,picturedbelow,isanotheroptionavailable.Thiscutoutrevealsthecolorofthestovethroughthecutoutshapes.
5.938"
11.938"
Frame Tile/Slate
direct vent wall Passthrough kitYoumay choose to use the optional Direct VentWallPassthroughKit (part #1-00-677177)which incorporatesventingpassthroughandoutsideairintoonecomponent.
On the rear of the stove hopper there is a hole to fasten the hopper extension into place.On some units, this hole will need to beopened. You will notice a small uncut area on rear of the knockout. Push downward with a screwdriver or like tool until the knockout is rotated as far back to the inside of the hopperas possible. This will allow the swell latch of thehopper extension to fully expand to the bottomside of the hole for a proper seal.
3-90-08422JR11_03/1427 PP38+ Pellet Stove
Harman® pellet burning, free-standing stoves and inserts have been tested to ASTM E1509 for burning shelled corn in a mixture with wood pellets. The listing approves up to a 50% corn and 50% pellet mixture. Different mixtures of corn will have distinctively different burn characteristics depending upon moisture content and variety. The operator should closely monitor the stove’s operation when burning a new corn/pellet mixture or a different variety of corn, and make any necessary adjustments to feed rate. Since corn is typically higher in ash and moisture content, cleaning and ash removal will be needed more frequently.
Operation in Stove Temp modeSet feed adjuster to # 3. Set temperature knob to #3, Turn mode selector knob onto “Stove Temp” mode. After the fire has lit, watch that the fuel does not feed too fast that it pushes the red glowing fuel bed off of the burn pot grate. If it does, lower the feed adjuster setting or use a lower percentage of corn in the mixture. After the stove has burned for 10 minutes and the entire fuel bed is burning, the feed adjuster and temperature knobs may be adjusted for higher heat output if desired. Maximum feed has been reached when the fire bed is about ½ to 1 inch from the end of the burn pot. Settings will vary with different types, moisture levels and mix ratios of corn. If you are having difficulty burn-ing a 50% corn / 50% wood pellet mixture, try a lower percentage of corn.
Operation in Room Temp modeSet feed adjuster to # 2 or # 3. Set temperature knob to desired amount. Turn mode selector knob onto “Room Temp” mode. After the fire has lit, watch that the fuel does not feed too fast that it pushes the red glowing fuel bed off of the burn pot grate. After the stove has burned for 10 minutes and the entire fuel bed is burning, the feed adjuster may be set to a higher output level if desired. Maximum feed has been reached when the fire bed is about ½ to 1 inch from the end of the burn pot. It is recommended that after burning at the desired settings, turn the stove off and allow it to cool, then turn it back on in “Room Temp” mode and watch the stove restart and verify correct operation. Settings will vary with different types, moisture levels and mix ratios of corn. If you are having difficulty burning a 50% corn 50% wood pellet mixture, try a lower percentage of corn.
Changes to Maintenance ScheduleWood pellets average around 6% moisture content or less. Corn will be 14 or 15% moisture. With more moisture in the fuel, more maintenance will be incurred. Burn pot scraping may need to be done once per day. The ash pan will fill more quickly and may need emptied weekly. Most importantly, remove the burn pot cleanout cover weekly to clean the air passage and the igniter element. Excessive buildup on the igniter may lead to shortened igniter life.
Venting Consideration: Check with your venting manufacturer regarding possible exclusions when a mixture of corn and pellets is burned.
Addendum for Burning Corn and Pellet Fuel Mixture
Loosen these two wing screws for access to clean the air passage and igniter.
* For P38+ model, follow Stove Temp instructions. Keep feed rate on #3 or above when using a wall thermostat.
28PP38+ Pellet Stove3-90-08422JR11_03/14
Fuel SpecificationsFuel and Fuel storagePellet fuel quality can fluctuate from manufacturer tomanufacturer,andevenfrombagtobag.Hearth&HomeTechnologiesrecommendsusingonlyfuelthatiscertifiedbythePelletFuelsInstitute(PFI).FuelMaterial• Madefromsawdustand/orotherwoodby-products• Shelledfieldcorn(whenmixedwithwoodpellets)• Sourcematerialtypicallydeterminesashcontent
HigherAshContentMaterial• Hardwoodswithhighmineralcontent• Barkandleavesassourcematerial• "Standard"gradepellets,cornandotherbiomass
LowerAshContentMaterial• Softwood;pine,fir,etc.• Materialswithlowermineralcontent• "Premium"gradepellets
Shelledfieldcorn• Mustbe15%moisturecontentorless• Mustbecleanandfreeofdebris• Mustbemixedwithwoodpellets.(Upto50%)• Stalk parts, excessive fines and cob remnants may
causefeedsystemjamsorblockage
CAUTION! Do not burn fuel that contains an additive; (such as soybean oil) • Maycausehopperfire• DamagetoproductmayresultRead the list of ingredients on the packaging. If you arebuyingfieldcorn,theonlyingredient listedshouldbefieldcorn.
WARNING! Risk of Chemical Poisoning!DoNOTburntreatedseedcorn• Chemicalpesticidesareharmfulorfatalifswallowed• Burningtreatedseedcornwillvoidtheproductwarranty
ClinkersMinerals and other non-combustible materials, like sand,willturnintoahardglass-likesubstancewhenheated.Treesfromdifferentareaswillvaryinmineralcontent.Forthis reason, some fuels will produce more clinkers thanothers.
MoistureAlways burn dry fuel. Burning fuel with high moisturecontenttakesenergytodryandtendstocooltheappliancethus,robbingheatfromyourhome.Damppelletfuelcouldturnbackintosawdustwhichdoesnotflowproperlythroughthefeedsystem.
Size• Pellets are either 1/4 inch or 5/16 inch (6-8mm) in
diameter• Lengthshouldbenomorethan1-1/2inches(38mm)• Pellet length can vary from lot to lot from the same
manufacturer
Performance• Higherashcontentrequiresmorefrequentmaintenance.• "Premium" grade pelletswill produce the highest heat
output.• Burning pellets longer than 1-1/2 inches (38mm) can
causeinconsistentfeedingand/orignition.
Werecommendthatyoubuyfuelinmulti-tonlotswheneverpossible. However, we do recommend trying differentbrands prior to purchasing multi-ton lots, to ensure yoursatisfaction.
CAUTION! Attempting to burn fuels such as charcoal has the potential of generating Carbon Monoxide which is DEADLY. Never burn fuels other than those listed on the appliance safety label.
Whenchangingfromwoodpelletstoacorn/pelletmixture,theFEEDADJUSTERwill likelyneedadjusted toa lowersetting.Whenundermaximumdemand,ensurethereisnounburnedfuelbeingpushedintotheashpan.
Storage• Woodpelletsshouldbeleft intheiroriginalsealedbag
untilreadytouse,topreventmoisture.• Shelledcornshouldbestoredinatightlysealedcontainer
topreventmoistureandtodeterpests• Donotstorefuelwithinthespecifiedclearanceareas,or
inalocationthatwillinterferewithroutinecleaningandmaintenanceprocedures.
noticeHearth&HomeTechnologiesisnotresponsibleforstove performance or extra maintenance requiredasaresultofusing fuelwithhigherashormineralcontent.
TestedandapprovedforusewithwoodpelletsandamixtureofshelledfieldcornandwoodpelletsONLY.Burningofanyotherfuelwillvoidyourwarranty.
CAUTION!
29 PP38+ Pellet Stove 3-90-08422JR11_03/14
18/3 RUBBER CORD
MA
LE/F
EMA
LE C
ON
NEC
TIO
NS
DIS
TRIB
UTI
ON
BLO
WER
FEED
ER A
UG
ER M
OTO
R
STA
ND
ARD
USE
WAT
TS -
336
@ 1
00VA
C 50
Hz
= 2.
8 A
LOW
PRE
SSU
RE S
WIT
CH
COM
BUST
ION
MO
TOR
N.O
. CO
NTA
CTS
MA
LE/F
EMA
LE C
ON
NEC
TIO
NS
1 42 3 65 987
WH
ITE
WH
ITE
WH
ITE
WH
ITE
BLU
E
EMPT
YEM
PTY
PLU
GG
EDBR
OW
N
11BL
ACK
PART
NO
. 3-9
0-77
3869
J
WHITE 11 PIN PLUG
10RE
D
GRE
EN
BON
DED
TO
STO
VE B
OD
YG
REEN
WIR
E IS
GRO
UN
D
18/3
RU
BBER
CO
RD
POW
ER C
ORD
ESP
HA
RMA
N P
38 P
ELLE
T ST
OVE
WIR
ING
DIA
GRA
M
BOA
RD
CON
TRO
L
BRO
WN
WH
ITE
RED
BLU
E
WH
ITE
WHITE
GREEN
MA
LE/F
EMA
LE C
ON
NEC
TIO
NS
ESP
BLACK
ROO
M S
ENSO
R PO
RTS
WHITE
ESP
PRO
BE
31 9 10 115 6 84
6 A
MP
GLA
SS F
USE
MAX
. WAT
TS -
336
@ 1
00/1
20VA
C 50
Hz/
60H
z =
2.8
A
wiring diagram
3-90-08422JR11_03/14
4021-645F02-18-13 Page1of2
hearth & home technologiesliMited liFetiMe warrantY
Hearth&HomeTechnologies,onbehalfofitshearthbrands(”HHT”),extendsthefollowingwarrantyforHHTgas,wood,pellet,coalandelectrichearthappliancesthatarepurchasedfromanHHTauthorizeddealer.
warrantY coverage:HHTwarrantstotheoriginalowneroftheHHTapplianceatthesiteofinstallation,andtoanytransfereetakingownershipoftheapplianceatthesiteofinstallationwithintwoyearsfollowingthedateoforiginalpurchase,thattheHHTappliancewillbefreefromdefectsinmaterialsandworkmanshipatthetimeofmanufacture.Afterinstallation,ifcoveredcompo-nentsmanufacturedbyHHTarefoundtobedefectiveinmaterialsorworkmanshipduringtheapplicablewarrantyperiod,HHTwill,atitsoption,repairorreplacethecoveredcomponents.HHT,atitsowndiscretion,mayfullydischargeallofitsobligationsundersuchwarrantiesbyreplacingtheproductitselforrefundingtheverifiedpurchasepriceoftheproductitself.Themaximumamountrecoverableunderthiswarrantyislimitedtothepurchasepriceoftheproduct.Thiswarrantyissubjecttoconditions,exclusionsandlimitationsasdescribedbelow.
warrantY Period:Warrantycoveragebeginsonthedateoforiginalpurchase.Inthecaseofnewhomeconstruction,warrantycoveragebeginsonthedateoffirstoccupancyofthedwellingorsixmonthsafterthesaleoftheproductbyanindependent,authorizedHHTdealer/distributor,whicheveroccursearlier.Thewarrantyshallcommencenolaterthan24monthsfollowingthedateofproductshipmentfromHHT,regardlessoftheinstallationoroccupancydate.Thewarrantyperiodforpartsandlaborforcoveredcomponentsisproducedinthefollowingtable.Theterm“LimitedLifetime”inthetablebelowisdefinedas:20yearsfromthebeginningdateofwarrantycoverageforgasappliances,and10yearsfromthebeginningdateofwarrantycoverageforwood,pellet,andcoalappliances.Thesetimeperiodsreflecttheminimumexpectedusefullivesofthedesignatedcomponentsundernormaloperatingconditions.
Seeconditions,exclusions,andlimitationsonnextpage.
Parts Labor Gas Wood Pellet EPAWood Coal Electric Venting
X X X X X X X
AllpartsandmaterialexceptascoveredbyConditions,
Exclusions,andLimitationslisted
X X X Igniters,electroniccomponents,andglass
X X X X X Factory-installedblowersX Moldedrefractorypanels
X Firepotsandburnpots
5years 1year X X Castingsandbaffles
7years 3years X X X Manifoldtubes,HHTchimneyandtermination
10years 1year X Burners,logsandrefractory
LimitedLifetime 3years X X X X X Fireboxandheatexchanger
X X X X X X X Allreplacementpartsbeyondwarrantyperiod
WarrantyPeriod HHTManufacturedAppliancesandVenting
1Year
ComponentsCovered
3years
2years
90Days
3-90-08422JR11_03/1431 PP38+ Pellet Stove
4021-645F02-18-13 Page2of2
warrantY conditions:• ThiswarrantyonlycoversHHTappliancesthatarepurchasedthroughanHHTauthorizeddealerordistributor.Alistof
HHTauthorizeddealersisavailableontheHHTbrandedwebsites.• ThiswarrantyisonlyvalidwhiletheHHTapplianceremainsatthesiteoforiginalinstallation.•ThiswarrantyisonlyvalidinthecountryinwhichtheHHTauthorizeddealerordistributorthatsoldtheappliance
resides.• Contactyourinstallingdealerforwarrantyservice.Iftheinstallingdealerisunabletoprovidenecessaryparts,contact
thenearestHHTauthorizeddealerorsupplier.Additionalservicefeesmayapplyifyouareseekingwarrantyservicefromadealerotherthanthedealerfromwhomyouoriginallypurchasedtheproduct.
• Checkwithyourdealerinadvanceforanycoststoyouwhenarrangingawarrantycall.Travelandshippingchargesforpartsarenotcoveredbythiswarranty.
this warranty is void if:• Theappliancehasbeenover-firedoroperatedinatmospherescontaminatedbychlorine,fluorine,orotherdamaging
chemicals.Over-firingcanbeidentifiedby,butnotlimitedto,warpedplatesortubes,rustcoloredcastiron,bubbling,crackinganddiscolorationofsteelorenamelfinishes.
• Theapplianceissubjectedtoprolongedperiodsofdampnessorcondensation.• Thereisanydamagetotheapplianceorothercomponentsduetowaterorweatherdamagewhichistheresultof,but
notlimitedto,improperchimneyorventinginstallation.
liMitations oF liabilitY:• Theowner’sexclusiveremedyandHHT’ssoleobligationunderthiswarranty,underanyotherwarranty,expressor
implied,orincontract,tortorotherwise,shallbelimitedtoreplacement,repair,orrefund,asspecifiedabove.InnoeventwillHHTbeliableforanyincidentalorconsequentialdamagescausedbydefectsintheappliance.Somestatesdonotallowexclusionsorlimitationofincidentalorconsequentialdamages,sotheselimitationsmaynotapplytoyou.Thiswarrantygivesyouspecificrights;youmayalsohaveotherrights,whichvaryfromstatetostate.EXCEPTTOTHEEXTENTPROVIDEDBYLAW,HHTMAKESNOEXPRESSWARRANTIESOTHERTHANTHEWARRANTYSPECIFIEDHEREIN.THEDURATIONOFANYIMPLIEDWARRANTYISLIMITEDTODURATIONOFTHEEXPRESSEDWARRANTYSPECIFIEDABOVE.
warrantY eXclusions:Thiswarrantydoesnotcoverthefollowing:• Changesinsurfacefinishesasaresultofnormaluse.Asaheatingappliance,somechangesincolorofinteriorand
exteriorsurfacefinishesmayoccur.Thisisnotaflawandisnotcoveredunderwarranty.• Damagetoprinted,plated,orenameledsurfacescausedbyfingerprints,accidents,misuse,scratches,melteditems,
orotherexternalsourcesandresiduesleftontheplatedsurfacesfromtheuseofabrasivecleanersorpolishes.• Repairorreplacementofpartsthataresubjecttonormalwearandtearduringthewarrantyperiod.Theseparts
include:paint,wood,pelletandcoalgaskets,firebricks,grates,flameguides,batteriesandthediscolorationofglass.• Minorexpansion,contraction,ormovementofcertainpartscausingnoise.Theseconditionsarenormalandcom-
plaintsrelatedtothisnoisearenotcoveredbythiswarranty.• Damagesresultingfrom:(1)failuretoinstall,operate,ormaintaintheapplianceinaccordancewiththeinstallation
instructions,operatinginstructions,andlistingagentidentificationlabelfurnishedwiththeappliance;(2)failuretoinstalltheapplianceinaccordancewithlocalbuildingcodes;(3)shippingorimproperhandling;(4)improperopera-tion,abuse,misuse,continuedoperationwithdamaged,corrodedorfailedcomponents,accident,orimproperly/incorrectlyperformedrepairs;(5)environmentalconditions,inadequateventilation,negativepressure,ordraftingcausedbytightlysealedconstructions,insufficientmake-upairsupply,orhandlingdevicessuchasexhaustfansorforcedairfurnacesorothersuchcauses;(6)useoffuelsotherthanthosespecifiedintheoperatinginstructions;(7)installationoruseofcomponentsnotsuppliedwiththeapplianceoranyothercomponentsnotexpresslyauthorizedandapprovedbyHHT;(8)modificationoftheappliancenotexpresslyauthorizedandapprovedbyHHTinwriting;and/or(9)interruptionsorfluctuationsofelectricalpowersupplytotheappliance.
• Non-HHTventingcomponents,hearthcomponentsorotheraccessoriesusedinconjunctionwiththeappliance.• Anypartofapre-existingfireplacesysteminwhichaninsertoradecorativegasapplianceisinstalled.• HHT’sobligationunderthiswarrantydoesnotextendtotheappliance’scapabilitytoheatthedesiredspace.Informa-
tionisprovidedtoassisttheconsumerandthedealerinselectingtheproperappliancefortheapplication.Consider-ationmustbegiventoappliancelocationandconfiguration,environmentalconditions,insulationandairtightnessofthestructure.
3-90-08422JR11_03/1432 PP38+ Pellet Stove
service Parts P38 Pellet (japan)beginning Manufacturing date: Feb 2011
ending Manufacturing date: active
Part number list on following page.
1-90-08505-1 (black),
ending Manufacturing date: june 20111-90-08505-2 (charcoal), 1-90-08505-3 (goldenfi re))
1
32
4
5
8
6 7
9 1011 12
13
16
15
14
1718
19
20
2122
23
steel Pellet stove
10/13
3-90-08422JR11_03/1433 PP38+ Pellet Stove
service Parts P38 Pellet (japan)beginning Manufacturing date: Feb 2011
ending Manufacturing date: active
IMPORTANT:THISISDATEDINFORMATION.Partsmustbeorderedfromadealerordistributor.hearth and home technologies does not sell directly to consumers.Providemodelnumberandserialnumberwhenrequestingservicepartsfromyourdealerordistributor.
iteM description coMMents Part nuMber1 HopperAssembly 1-10-09539A
HopperThroatGasket 3-44-677185HopperSwitch48” 3-20-232108
2 FeederAssembly 1-10-09535JA2.1 PelletFeederGearMotor,4RPM 3-20-501202.2 ULFeederCamBearing 3-31-30142.3 FeederAirCrossoverKit 1-00-67900
9MMSiliconeTube 5Ft 1-00-5114272.4 PelletAirIntakeAssembly 1-10-06810A2.5 GasketFeederAirIntake Pkgof6 3-44-72224-62.6 ULFeederAirIntake 1-10-722222.7 GasketUltraAirIntake Pkgof10 3-44-677160-102.8 UltraFeederWeldment 1-10-7241322.9 ULFeederPusherArm 1-10-677187W2.10 Gasket,ULFeederCover 1-00-6771222.11 SlidePlateAssembly 1-10-677121A2.12 ULFeederAugerAssembly 3-50-005652.13 BearingFlangew/Hardware 1-00-040352.14 ULFeederGearMotorBracketw/Grommet 1-00-2474062.15 ULFeederCamBlock 3-00-677154
HopperSwitchfitting Pkgof2 1-00-142818MotorBracketGrommet Pkgof12 3-31-2761-12PillowBlock Pkgof4 3-31-3614087-4
Additionalservicepartsonfollowingpage.
2.7
2.6
2.5
2.4
2.3
2.2
2.1
2.15
2.8
2.9
2.10
2.11
2.12
2.13
2.14
#2 Feeder assembly
3-90-08422JR11_03/1434 PP38+ Pellet Stove
service Parts P38 Pellet (japan)beginning Manufacturing date: Feb 2011
ending Manufacturing date: active
IMPORTANT:THISISDATEDINFORMATION.Partsmustbeorderedfromadealerordistributor.hearth and home technologies does not sell directly to consumers.Providemodelnumberandserialnumberwhenrequestingservicepartsfromyourdealerordistributor.
iteM description coMMents Part nuMber3 FlueTailPipe 3-00-2472374 AugerMotorCover 2-00-773852J5 AugerMotorShield 2-00-773815P6 DifferentialSwitch 3-20-68667 DistributionBlower 3-21-336478 CombustionMotor 3-21-09640
CombustionBlowerMountingScrews Pkgof100 1-00-534832089 RearCoverLeft 2-00-773828-1P10 RearCoverRight 2-00-773828-2P11 CombustionIntakeWeldment 1-10-08516S12 RetainerAssembly 1-10-08533S13 AshPan 1-10-7738108A14 AshDoorAssembly 1-10-7738106A15 BoltonHingeWeldment 2-00-06952B16 CastDoorFrame 4-00-06800P
CastDoorw/Glass 1-10-06800A17 GlassPanel 3-40-950133125
18 DoorHandleAssembly(Contains:PawBolt,WoodenHandle,WashersandScrews.) 1-00-453001
WoodenHandle,LoadDoor 1-00-0024719 BurnPotWeldment 1-10-08514
FlameGuide 3-00-08534CleanOutCover 2-00-06112ThumbScrew Pkgof10 3-31-782108-10
20FireBrick4-1/2x9x1-1/4" Pkgof7 1-00-900450125FireBrick,FullSkid 414Pcs 3-40-900450-414
21 HopperHeatShield 2-00-773854B22 FeederCover 2-00-77385323 CircuitBoardw/Knobs&Shafts 1-00-06142
CircuitBoardPlate 1-10-08649Knob,ContolBoard/D-Shaft 25Sets 1-00-015605
Additionalservicepartsonfollowingpage.
3-90-08422JR11_03/1435 PP38+ Pellet Stove
service Parts P38 Pellet (japan)beginning Manufacturing date: Feb 2011
ending Manufacturing date: active
IMPORTANT:THISISDATEDINFORMATION.Partsmustbeorderedfromadealerordistributor.hearth and home technologies does not sell directly to consumers.Providemodelnumberandserialnumberwhenrequestingservicepartsfromyourdealerordistributor.
iteM description coMMents Part nuMberAirwashO-Rings Pkgof10 1-00-939639ArrowBurnPotScraper Pkgof10 2-00-773850-10CastWeldonDoorHinge Qty2req 3-00-773813DiagnosticDisplayModule 3-20-05401
DDMReplacementCable 1-00-05402
Disconnect,Female Pkgof25 1-00-00959DraftMeterAssembly 1-00-00637
DraftMeterBolt&Tube 1-00-04004
FanBlade,5”DoublePaddle(CombustionBlower) 3-20-502221Fuse,6Amp Pkgof5 3-20-49447-5Gasket,1/4”RopeBlackW/PSA(Glass) 15Ft 1-00-2312Gasket,3/8”RopeWhiteLD(AshDoororLoadDoor) 30Ft 1-00-00888Gasket,BurnPot/Tailpipe Pkgof5 1-00-07381Gasket,Hopper 10Ft 1-00-00248GlassClip&Hardware 1Set 1-00-249140HopperLidW/HInge 1-10-08518Labels,Caution&Danger 10ea 1-00-200408541Label,Caution 3-90-00247Latch,Swell/HopperAndSpacer 1-00-199110
RubberSpacers Pkgof10 3-31-901311-10OutsideAirVent 1-10-09542PowerCord 3-20-39685RoomSensor 3-20-00906Screw,#10-24x3/8”AlloySteelBlackOxideButtonHeadCap Pkgof100 3-30-3011-100SiliconeTubing,1/8” 5Ft 1-00-5113574ThermisterProbe(ESPProbe) 3-20-00844WiringHarness Pre008190059 3-20-773868WiringHarness Post008190059 3-20-08727
TileFrameGold 3-43-06729-4BrushedStainless 3-43-06729-7BrightNickel 3-43-06729-8
SpringClips(RequiredforinstallationofTileFrame) Pkgof20 3-31-232547-20
LeafDoorTrimGold 3-43-06802-4BrushedStainless 3-43-06802-7BrightNickel 3-43-06802-8
ModernDoorTrim BrushedStainless 3-43-06839-7
AshlipTrimGold 3-43-08400BrushedStainless 3-43-08400-7BrightNickel 3-43-08400-8
37 PP38+ Pellet Stove 3-90-08422JR11_03/14
service & Maintenance log
date of service description of servicePerformed by
At Harman, we build each product to a standard, not a price.This powerful heating appliance boasts uncompromising attention to detail and helps preserve our planet by using environmentally responsible fuels.
(Signature of Boxer)
Your premium quality hearth product designed and assembled by the experienced and skilled members at Harman in Halifax, PA, USA.
Proudly Printed On 100% Recycled Paper