NOTICE OF PUBLIC HEARING June 12, 2018,

21
CITY OF CAMPBELL Community Development Department 70 North First Street - Campbell, California 95008-1423 - TEL 408.866.2140 - FAX 408.871-5140 - TDD 408.866-2790 June 1, 2018 NOTICE OF PUBLIC HEARING Notice is hereby given that the Planning Commission of the City of Campbell has set the time of 7:30 p.m., or shortly thereafter, on Tuesday, June 12, 2018, in the City Hall Council Chambers, 70 North First Street, Campbell, California, for a Public Hearing to consider the application of David Elliott for a Conditional Use Permit with Site and Architectural Review (PLN2018-123) to allow the conversion of an existing motor vehicle repair and maintenance facility to a convenience market with late night activities and beer and wine sales for off-site consumption; and the addition of a hydrogen fueling facility within an existing (Chevron) service station on property located at 337 E. Hamilton Avenue. Staff is recommending that this project be deemed Categorically Exempt under CEQA. Interested persons may appear and be heard at this hearing. Please be advised that if you challenge the nature of the above project in court, you may be limited to raising only those issues you or someone else raised at the Public Hearing described in this Notice, or in written correspondence delivered to the City of Campbell Planning Commission at, or prior to, the Public Hearing. Questions may be addressed to the Community Development Department at (408) 866-2140. Plans and architectural drawings may be viewed at the Planning Division office during normal business hours (8:00 a.m. – 5:00 p.m.) and on the City's 'Public Notices' web page (http://www.cityofcampbell.com/501/Public-Notices) under ‘Planning Commission’. Decisions of the Planning Commission may be appealed to the City Council. Appeals must be submitted to the City Clerk in writing within 10 calendar days of an action by the Commission. In compliance with the Americans with Disabilities Act, listening assistive devices are available for all meetings held in the Council Chambers. If you require accommodation, please contact the Community Development Department at (408) 866-2140, at least one week in advance of the meeting. PLANNING COMMISSION CITY OF CAMPBELL PAUL KERMOYAN SECRETARY PLEASE NOTE: When calling about this Notice, please refer to: 337 E. Hamilton Avenue

Transcript of NOTICE OF PUBLIC HEARING June 12, 2018,

Page 1: NOTICE OF PUBLIC HEARING June 12, 2018,

CITY OF CAMPBELL

Community Development Department

70 North First Street - Campbell, California 95008-1423 - TEL 408.866.2140 - FAX 408.871-5140 - TDD 408.866-2790

June 1, 2018

NOTICE OF PUBLIC HEARING Notice is hereby given that the Planning Commission of the City of Campbell has set the time of 7:30 p.m., or shortly thereafter, on Tuesday, June 12, 2018, in the City Hall Council Chambers, 70 North First Street, Campbell, California, for a Public Hearing to consider the application of David Elliott for a Conditional Use Permit with Site and Architectural Review (PLN2018-123) to allow the conversion of an existing motor vehicle repair and maintenance facility to a convenience market with late night activities and beer and wine sales for off-site consumption; and the addition of a hydrogen fueling facility within an existing (Chevron) service station on property located at 337 E. Hamilton Avenue. Staff is recommending that this project be deemed Categorically Exempt under CEQA. Interested persons may appear and be heard at this hearing. Please be advised that if you challenge the nature of the above project in court, you may be limited to raising only those issues you or someone else raised at the Public Hearing described in this Notice, or in written correspondence delivered to the City of Campbell Planning Commission at, or prior to, the Public Hearing. Questions may be addressed to the Community Development Department at (408) 866-2140. Plans and architectural drawings may be viewed at the Planning Division office during normal business hours (8:00 a.m. – 5:00 p.m.) and on the City's 'Public Notices' web page (http://www.cityofcampbell.com/501/Public-Notices) under ‘Planning Commission’. Decisions of the Planning Commission may be appealed to the City Council. Appeals must be submitted to the City Clerk in writing within 10 calendar days of an action by the Commission. In compliance with the Americans with Disabilities Act, listening assistive devices are available for all meetings held in the Council Chambers. If you require accommodation, please contact the Community Development Department at (408) 866-2140, at least one week in advance of the meeting.

PLANNING COMMISSION

CITY OF CAMPBELL PAUL KERMOYAN

SECRETARY PLEASE NOTE: When calling about this Notice, please refer to: 337 E. Hamilton Avenue

Page 2: NOTICE OF PUBLIC HEARING June 12, 2018,

CE

NT

RA

L A

VE

HAMILTON AVE

HA

RR

ISO

N A

VE

ME

RR

Y L

N

MO

NIC

A L

N

ROSEMARY LN

HAMILTON AVE

HA

RR

ISO

N A

VE

Project Location Map

Project Location: 337 E. Hamilton AvenueProject Name: Chevron Station

±0 625312.5Feet

Community Development DepartmentPlanning Division

Project Site

Page 3: NOTICE OF PUBLIC HEARING June 12, 2018,

North

(E)

I#

Top Of CurbTowel BarTread

OCL@

L&WT.WSCT.WP.W/OWD.W.C.

W/W

VEST.VERT.UR.U.O.N.UNF.

TYP.T.W.T.V.T.P.D.T.P.THK.T.& G.TER.TEL.T.C.T.B.TRD.

SYM.SUSP.STA.STRL.STOR.STL.STD.S.SK.SST.SQ.SPEC.S.N.R.S.N.D.SIM.SHT.SHR.SH.SECT.S.D.SCHED.S.C.D.S.C.S.

R.W.L.RWD.RM.RESIL.REQ.REINF.RGTR.REFR.REF.R.D.RAD.R.

Q.T.

PTD/RP.T.D.PT.PR.PLYWD.PLAS.P.LAM.PL.PRCST.

OPP.OPNG.OFF.O.D.O.C.OBS.O.A.

N.T.S.NOM.

NO. or # N.I.C.N.

MUL.MTD.M.O.MISC.

MIR.MIN.M.H.MFR.MET.MEMB.MECH.M.C.MAX.ACOUS.

A.D.ADJ.AGRR.

APPROX.ARCH.ASB.ASPH.

BITUM.BLDG.BLK.BLKGBM.BOT.

CAB.

CEM.CER.

CLG.CLKG.CLO.CLR.COL.CONC.CONN.CONSTR.CONT.CORR.CTSK.CNTR.CTR.

DBL.DEPT.D.F.DET.DIA.DIM.DISP.

D.O.

DWR.D.S.D.S.P.Drawing

ELEC.ELEV.EMER.ENCL.E.P.E.Q.EQPT.E.W.C.EXST.EXPO.EXP.EXT.

F.A.F.B.F.D.FDN.F.E.F.E.C.F.H.C.FIN.

FLASH.FLUOR.F.O.C.F.O.F.F.O.S.FPRF.F.S.

FTG.FURR.FUT.

GALV.G.B.

GND.

GYP.

H.B.H.C.HDWD.HDWE.H.M.HORIZ.

HGT.

INSUL.INT.

JAN.

KIT.

LAB.LAM.LAV.LKR.

Small Scale

Large Scale

at Small Scale)

(Blocking, Interrupted)

(Continuous)

(Omit Indication

(Omit Indicationin Thin Material)

at Small Scale)(Omit Indication

(Profile Only)

(Profile Only)

in Thin Material)(Omit Indication

LargeSmall

SmallLarge

Cast-in-Place/Precast

Compacted Backfill

Natural/Engineered Fill

Planter Backfill

See Sheet A1.1 For Continuation

Shaded Side Shown This Sheet

Sheet Number Where Drawn

Section Number

Sheet Number Where DrawnDetail Number

PLAN NORTH

Detail Number

Sheet Number Where Drawn

DETAILS, PLANS, BUILDING SECTIONS, WALL SECTIONS,ETC. ARE REFERENCED BY NUMBERS ACCORDING TOTHEIR LOCATION ON THE SHEET AS INDICATED ABOVE.

DEFERRED PERMITS:* FIRE ALARM SYSTEMS

7. AIR CONDITION UNITS: AIR CONDITION UNITS AND VENTILATION DUCTS SHALL BE SCREENED FROM PUBLIC VIEW WITH MATERIALS COMPATIBLE TO THE MAIN BLDG. UNITS SHALL BE PERMANENTLY INSTALLED ON CONCRETE PADS OR OTHER NON-MOVABLE

MATERIALS TO APPROVED BY THE BUILDING OFFICIAL AND DIRECTOR OF COMMUNITYDEVELOPMENT

8. TEMPORARY FENCING: TEMPORARY CONSTRUCTION FENCING SHALL BE INSTALLED ALONG PERIMETER OF ALL WORK UNDER CONSTRUCTION.

9. COOL ROOFS: FLAT ROOF AREAS SHALL HAVE THEIR ROOFING MATERIALCOATED WITH LIGHT COLORED GRAVEL OR PAINTED WITH LIGHT COLORED OR REFLECTIVE MATERIAL DESIGNED FOR COOL ROOFS.

10. ELECTRONIC FILE: THE APPLICANT/DEVELOPER SHALL SUBMITT ALL BUILDING DRAWINGS AND SPECIFICATIONS FOR THIS PROJECT IN AN ELECTRONIC FORMAT TO THE SATISFACTION OF THE BUILDING OFFICIAL PRIOR TO THE ISSUANCE OF BUILDING PERMITS. ADDITIONALLY, ALL REVISIONS MADE TO THE BUILDING PLANS DURING THE PROJECT SHALL BE INCORPORATED INTO AN "AS BUILT" ELECTRONIC FILE AND SUBMITTED PRIOR TO THE ISSUANCE OF THE FINAL OCCUPANCY.

6. the project will be subject to all fire code requirements in effect at the time of building permit plan check submittal.

6. ENGINEER OBSERVATION: THE ENGINEER OF RECORD SHALL BE RETAINED TO PROVIDE OBSERVATION SERVICES FOR ALL COMPONENTS OF THE LATERAL AND VERTICAL DESIGN OF THE BUILDING, INCLUDING NAILING, HOLD-DOWNS, STRAPS, SHEAR, ROOF DIAPHRAGM AND STRUCTURAL FRAME OF THE BUILDING. A WRITTEN REPORT SHALL BE SUBMITTED TO THE CITY INSPECTOR PRIOR TO SCHEDULING THE FINAL FRAME INSPECTION.

PROJECT:SERVICE STATION337 EAST HAMILTON AVE.CAMPBELL, CA. 95008OWNER: MIKE KHAZIRI

SCOPE OF WORK:THE EXISTING 1,653 S.F. SERVICE BAYS STATION IS REMODELED TO CONVERT INTO A CONVENIENCE STORE.NEW HYDROGEN STATION ENCLOSURE AND A NEW PUMP ADDED. EXISTING UTILITIES ARE UPGRADED.NEW A.D.A COMPLIANT RESTROOM IS ADDED.

SHT. # SHEET TITLE

TITLE

A0.1COVER SHEET, GENERAL NOTES, SYMBOLS andABBREVIATIONS

C1 BOUNDARY AND TOPOGRAPHIC SURVEYC2 CIRCULATION PLAN

ARCHITECTURALA1.1 EXISTING SITE PLANA1.2 NEW SITE PLANA1.3 ACCESSIBLE PARKING & DETAILSA1.4 TRASH ENCLOSURE PLAN & DETAILSA2.0 EXISTING & DEMOLITION FLOOR PLANSA2.1 PROPOSED FLOOR PLANA2.2 EQUIPMENT FLOOR PLANA3.0 COLOR EXTERIOR ELEVATIONSA3.1 EXISTING EXTERIOR ELEVATIONSA3.2 NEW EXTERIOR ELEVATIONSA3.3 HYDROGEN ENCLOSURE EXTERIOR ELEVATIONSA3.4 CANOPY PLAN AND ELEVATIONSA3.5 ROOF PLANA4.1 ACCESSIBLE RESTROOMS AND DETAILSA6.1 REFLECTED CEILING PLANL1 PLANTING PLANL2 IRRIGATION PLAN

1. SUMMARY OF THE WORK: The Work shall consist of all labor, materials,equipment, tools, transportation, services, and operations necessary to furnish andinstall the work under separate subcontracts, including all auxiliary and incidentalwork and materials necessary to complete compatible and operable installations asshown on the Drawings and Outline Specifications. The Subcontractor shallcooperate with the Owner's superintendent in all aspects, including agency

2. COORDINATION: Before submitting the proposal for the Work, thecontractor shall visit the site and become familiar with all the work with otherrelated drawings and specifications, and plan his work to provide the best possibleassembly of combined work of all trades. No additional cost will be considered forwork, which has to be relocated due to conflicts with other trades.

3. DRAWINGS: The Drawings are schematic, dimensions given on the planstake precedence over scaled dimensions, and all dimensions shall be verified in thefield. The exact location of apparatus equipment shall be ascertained from theOwner's superintendent in the field. The Owner reserves to make minor changes inthe location of any equipment up to the time of installation without additional

4. ERRORS AND OMISSIONS: The subcontractor shall not take advantage ofany unintentional error or omission in the Drawings or Outline Specifications. Hewill be expected to furnish all necessary items of materials, labor etc., which arenecessary to make a complete job to the true intent and meaning of theseSpecifications. Should there be any discrepancies on the Drawings or theseSpecifications the Subcontractor shall call the attention of the Superintendent thesame, and shall receive the complete instructions in writing before proceeding withthat portion of the work. Failure to do so shall place the entire responsibility ofcorrecting the work or added expense if a question is raised after the Bid Award orcontract on the Subcontractor.

5. LAWS, PERMITS, FEES AND NOTICES: The Subcontractor shall give noticesand comply with laws, ordinances, rules, regulations and orders of public authoritiesbearing on the performance of work. The Owner shall secure and pay for all fees,licenses and inspections necessary for proper execution and completion of thesubcontractor's work.

1. EXIT ILLUMINATION: Exit paths shall be illuminated anytime the building isoccupied with a light having an intensity of not less than one foot candle at floorlevel. Power shall normally be by the premises wiring with battery backup. Exitillumination is indicated on the Reflected Ceiling and Lighting Plan, sheet A6.1.

2. EXIT SIGNS: Exit signs shall be internally or externally illuminated andprovided with battery backup. Exit signs shall be posted above each required exitdoorway and wherever otherwise required to clearly indicate the direction of egress.

SITE AREA CALCULATIONS:EXISTING SITE 20,014 S.F TOTAL LANDSCAPE AREA 2,043 S.F.

PARKING : 7

BUILDING CODE : 2016 CALIFORNIA BUILDING CODE (CBC)

ELECTRICAL CODE: 2016 CALIFORNIA ELECTRICAL CODE (CEC)

MECHANICAL CODE: 2016 CALIFORNIA MECHANICAL CODE (CMC)

PLUMBING CODE: 2016 CALIFORNIA PLUMBING CODE (CPC)

ENERGY CODE: 2016 CALIFORNIA BUILDING ENERGY EFFICIENCY STANDARDS

GREEN CODE: 2016 CALIFORNIA GREEN BUILDING STANDARDS CODE

ACCESSIBILITY CODE: 2016 CALIFORNIA BUILDING CODE

BUILDING AREA CALCULATIONS.

AREA OCCUPANCY SF/ S.F. TYPE OCC. LOADMERCHANDISE 1,134 M 1/30 38BACKROOM 144 M 1/200 1SERVICE 150 M 1/200 1MISC. R, R, 225 M 0 0

TOTAL 1,653 M 40

TYPE OF CONST.: V-BNUMBER OF STORIES: 1BUILDING HEIGHT: 19'-6"EXITS: 1 REQUIRED, 1 PROVIDEDSPRINKLERS: NO

HAMILTON

MARKET PLACE

3 Address identification: New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. Where required by the fire code official, address numbers shall be provided in additional approved locations to facilitate emergency response. Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall be a minimum of 4 inches (101.6 mm) high with a minimum stroke width of 0.5 inch (12.7 mm). Where access is by means of a private road and the building cannot be viewed from the public way, a monument, pole or other sign or means shall be used to identify the structure. Address numbers shall be maintained. CFC Sec. 505.1

4. Water Supply Requirements: Potable water supplies shall be protected from contamination caused by fire protection water supplies. It is the responsibility of the applicant and any contractors and subcontractors to contact the water purveyor supplying the site of such project, and to comply with the requirements of that purveyor. Such requirements shall be incorporated into the design of any water-based fire protection systems, and/or fire suppression water supply systems or storage containers that may be physically connected in any manner to an appliance capable of causing contamination of the potable water supply of the purveyor of record. Final approval of the system(s) under consideration will not be granted by this office until compliance with the requirements of the water purveyor of record are documented by that purveyor as having been met by the applicant(s).

5. Construction Site Fire Safety: All construction sites must comply with applicable provisions of the CFC Chapter 33 and our Standard Detail and Specification SI-7. Provide appropriate notations on subsequent plan submittals, as appropriate to the project. CFC Chp. 33

LOT COVERAGE:EXISTING BLDG. 1,653s.f.EXISTING CANOPY 964s.f.NEW CANOPY 383s.f.NEW HYDROGEN ENCLOSURE 368s.f.NEW TRASH ENCLOSURE 149s.f.NEW PROPANE ENCLOSURE 72s.f.

TOTAL AREA 3,589s.f.

3,589s.f. / 20,014s.f. = 17% LOT COVERAGE.

1,982s.f. / 20,014s.f. = 9% LANDSCAPE COVERAGE.

FIRE NOTES:

14,443s.f. / 20,014s.f. = 74% PAVING COVERAGE.

20,014 / 20,014s.f. = 100%

Page 4: NOTICE OF PUBLIC HEARING June 12, 2018,

INTERNATIONAL, INC.

ACKLAND

Page 5: NOTICE OF PUBLIC HEARING June 12, 2018,

HAMILTON

MARKET PLACE

Page 6: NOTICE OF PUBLIC HEARING June 12, 2018,

HAMILTON

MARKET PLACE

Page 7: NOTICE OF PUBLIC HEARING June 12, 2018,

1

6 7

5

1

A1.3

10'-0"

10'-0"

11

32'-0"

13

9'-0"

5'-0" 10'-0"

9'-0"

18'-0"

9'-3"

145'-0"

10'-0"

5'-0"

18'-0

"

10'-0"

MIN

.

5'-0"

32'-0"

55'-0"

30'-0"

13

5'-0"

32'-0"

13

9

2

3

4

16

17

10'-0"

2'-0"

2'-0"

19-

17'-11

2"

37'-2"

30'-2"

19'-1"

11'-5"

1 PATH OF TRAVEL

2 Walkways and sidewalks along accessible routes of travel (1) arecontinuously accessible, (2) have Maximum 1/2" changes in elevation, or provide curb ramps complying with CBC 1127B.5; (3) are min.48" in width, and (4) where necessary to change elevation at a slope exceeding 5% (i.e., 1:20) shall have pedestrian ramps complying withCBC 1133B.5. CBC 1133B.7

3 The contractor using the city sidewalk to workon an adjacent private building must do so in amanner that is safe for pedestrians using thesidewalk. the work area must be coned or tapedoff while still leaving at least 4 feet of sidewalkfor pedestrians use. if less than 4 feet ofsidewalk is available for pedestrians, thecontractor must obtain an encroachment permitfrom public works to close the sidewalk.

5 44" min. clear Path of Travel

4 Exit doors are to be operable from inside withoutuse of a key, special knowledge or effort, However, key-lockinghardware may be used oh the main exitwhen the main exit door has a durable sign on or adjacent to the doorstating THIS DOOR MUST REMAINUNLOCKED WHEN BUILDING IS OCCUPIED. The sign shall bein letters not less than one inch high on a contrastingbackground. When unlocked, the door must be free toswing operation of any latching device.

7

8

9

10

11

12

6

13

14

HAMILTON

MARKET PLACE

15

16

17

PATH OF TRAVEL TOACCESSIBLE

60" A.F.G

11B-502.8.2 LETTERING.THE ADDITIONAL SIGN SHALLCLEARLY STATE IN LETTERSWITH A MIN. HEIGHT OF 1 INCH.

FOR STL. POSTBASE, SEE.

13

A1.3

ENTRANCE

Page 8: NOTICE OF PUBLIC HEARING June 12, 2018,

18'-0"

12" HIGHWHITE LETTERS

VAN ACCESSIBLESIGN

AISLE BORDERPAINTED BLUE

3'-0

" O

.C.

7-

I.S.A16-

9'-0" 8'-0"

WHEELSTOP

11B-406.5.3 LANDINGS.LANDINGS SHALL BE PROVIDED AT THETOP OF CURB RAMPS AND BLENDEDTRANSITIONS. THE LANDING CLEARLENGTH SHALL BE 48"MIN..THE LANDING CLEAR WIDTH SHALL BEAT LEAST AS WIDE AS THE CURB RAMP,EXCLUDING ANY FLARED SIDES, ORTHE BLENDED TRANSITION LANDINGTO THE LANDING. THE SLOPE OF THELANDING IN ALL DIRECTIONSSHALL BE 1:48 MAX.

11B-406.3.1 SLOPE.THE RUNNING SLOPE OF THECURB RAMP SEGMENT SHALLBE IN-LINE WITH THE DIRECTIONOF SIDEWALK TRAVEL.RAMP RUNS SHALL HAVE ARUNNING SLOPE NOTSTEEPER THAN 1:12

DETECTABLEWARNINGS

9-

FLARED SIDE1:10 MAX. SLOPE

4'-0" MIN.

11B-406.5.7 CROSS SLOPE.THE CROSS SLOPE OF CURBRAMPS AND BLENDEDTRANSITIONS SHALL BE 1:48 MAX.

1:1

2 M

AX

.S

LO

PE

1:10

MAX.

SLOPE

1:10 MAX.

SLOPE

ACCESSIBLE PARKINGIDENTIFICATION SIGN

"VAN ACCESSIBLE"SIGN @ VANACCESSBILITY SPACES

2" SQ. GALV. STL. POST

FINISH GRADE

2'-6"

2"

3" MIN. COVER @ POST

CONC. ENCASEMENT12" DIAMETER

80"

MIN

. A

T C

IRC

ULA

TIO

N P

AT

H2"

OT

HE

RW

ISE

60"

A.F

.G.

14-

11b-502.6.1 FINISH AND SIZE.PARKING IDENTIFICATION SIGNSSHALL BE REFLECTORIZED WITHMIN. AREA OF 70 SQUARE INCHES.

PARKINGONLYMINIMUM

FINE $250

VANACCESSIBLE

FOR STL. POSTBASE, SEE.

13-

80" MIN. A.F.G

VAN ACCESSIBLE SIGNWHERE APPLIES

11b-502.6.3 LOCATION.A PARKING IDENTIFICATION SIGNSHALL BE VISIBLE FROM EACHPARKING SPACE. SIGNS SHALL BEPERMANENTLY POSTED EITHERIMMEDIATELY ADJACENT TO THEPARKING SPACE OR WITHIN THEPROJECTED PARKING SPACE WIDTHAT THE HEAD END OF THE PARKING SPACE.SIGNS MAY ALSO BE PERMANENTLYPOSTED ON A WALL AT THE INTERIOREND OF THE PARKING SPACE.

17"

22"

OR SPECIAL LICENSE PLATES

DISABILITIES WILL BE TOWEDISSUED FOR PERSONS WITH

TOWED VEHICLES MAY BEAWAY AT THE OWNER'S EXPENSE.

DISTINGUISHING PLACARDS SPACES NOT DISPLAYING

IN DESIGNATED ACCESSIBLEUNAUTHORIZED VEHICLES PARKED

OR BY TELEPHONINGRECLAIMED AT XXXXXXX YYYY

831-678.xxxx

80" A.F.G

11B-502.8.2 LETTERING.THE ADDITIONAL SIGN SHALLCLEARLY STATE IN LETTERSWITH A MIN. HEIGHT OF 1 INCH.

FOR STL. POSTBASE, SEE.

13-

R 2 1/2"

3'-0"

12"

R 10"

13"

1½" 4"

14"

3'-0"

INTERNATIONAL SYMBOL OF ACCESSIBILITY.THE SYMBOL SHALL CONSIST OF A WHITEFIGURE ON A BLUE BACKGROUND. THE COLORBLUE SHALL APPROXIMATEFS 15090 IN FEDERAL STANDARD 595C.

CENTER LINEPARKING STALL

DIMENSIONSFOR REFERENCEONLY

2.3

-2.4

2.3-2.40.65"

TOP DIA.0.45-0.47

BASE DIA.0.9-0.92 0.18-0.22

ELEVATION A-A / N.T.S

PLAN

11B-705.1.1.3.1 COLOR AND CONTRAST.DETECTABLE WARNING SURFACESSHALL BE YELLOW ANDAPPROXIMATE "FS33538" OFFEDERAL STANDARD 595C.

11B-705.1.1.4 RESILIENCY.DETECTABLE WARNING SURFACESSHALL DIFFER FROM ADJOININGSURFACES IN RESILIENCY ORSOUND-ON-CANE CONTACT.

"DETECTABLE WARNINGS"11B-705.1

AA

11B-705.1.2.2 CURB RAMPS.DETECTABLE WARNING AT CURBRAMPS SHALL EXTEND 36" IN THEDIRECTION OF TRAVEL. DETECTABLEWARNINGS SHALL EXTEND THE FULLWIDTH OF THE RAMP RUN LESS 2"MAX. ON EACH END.

2'-4"

3'-8"

3'-0"

12"

2'-6"

22°

TRAFFICARROW

WHITE

1/4

"

1/4"

12", TYP.

1/4"

APPROX. 3/4" EXCEPTAPPROX. 1-1/2" ON SLOPING

PORTION OF THE RAMP

PERMANENT DECAL SIGN, MIN.4''x3'', TO BE POSTED ADJACENTTO THE LATCH SIDE OF THE SINGLEAND RIGHT SIDE OF THE DOUBLEDOOR +60" A.F.F.

1/2

" M

AX

.

11B-303.4 BEVELED.CHANGES IN LEVEL BETWEEN1/4" HIGH MIN. AND 1/2" HIGH MAX.SHALL BE BEVELED WITH ASLOPE NOT STEEPER THAN 1:2

1

2

1/4

"1/4

"

HAMILTON

MARKET PLACE

Page 9: NOTICE OF PUBLIC HEARING June 12, 2018,

8'-0"

36" MIN.

24"

MIN

.

12"

CEM.PLASTER

6'-0"

METAL ROOF

8'-2"

6'-0"

METAL ROOF

10'-8"

14'-0"

DRAIN

8'-2"

6'-0"

6" DEPH

CEM.PLASTER

6'-0"

9'-0"

8'-0"

BOLLARDS

PROPANETANK

HAMILTON

MARKET PLACE

Page 10: NOTICE OF PUBLIC HEARING June 12, 2018,

(E) 57'-6"

28'-9"

(E)

28'-9"

3'-0"10'-0"2'-0"10'-0"2'-0"10'-0"9'-238"3'-4"5'-113

16"

7'-0"

8'-2"

3'-4"

12"

12'-3"

12'-10"

D1

D2

D4

D6

D2

D4

D5 D5D5

D2

D4

EXISITING WALL

D2

DEMOLISH (E) PLUMBING FIXTURERS

D3

DEMOLISH EXISTING WALLS

D4

-

D5

DEMOLISH EXISTING DOOR AND DOOR FRAME-TYP.

D1

DEMOLISH EXISTING ROLL UP DOOR

D6 DEMOLISH EXISTING GARAGE EQUIPMENT

DEMOLITION WALL

EXISITING WALL

HAMILTON

MARKET PLACE

Page 11: NOTICE OF PUBLIC HEARING June 12, 2018,

NEW WALL

EXISTING WALL

NEW PARTIAL HEIGHT WALL

20'-6"

28'-9"

(E)

57'-6" (E)

20'-10"

7

A4.1

1

8'-6"12'-0"8'-2" 16'-10" 12'-0"

A A

2

1

MERCHANDISE

RESTROOM

BACK ROOM

SERVICE

11'-4"

3'-8"

7'-2"

7'-4" 27'-1"

3

1

7'-5"

7'-8"

#

1. POS COUNTER TO BE 28"-34" AFF, WITH A MINIMUM WIDTH OF36".

2. NEW 600A PANEL LOCATION

1

ELECTRICAL PANEL

#

2

PLUMBING FURRED WALL

3 (E) WALL

4 (N) F.R.P. 8' HIGH MINIMUM

HAMILTON

MARKET PLACE

Page 12: NOTICE OF PUBLIC HEARING June 12, 2018,

NEW DOORS

NEW STOREFRONT WINDOWS

(E) BRICK WALL

2

(E) FASCIA

(E) WINDOW

(E) ROOF

2

HYDROGEN ENCLOSURE SOUTH ELEVATION HYDROGEN ENCLOSURE EAST ELEVATION

SOUTHERN BREEZE

STONE GRAY

1

COLOR LEGEND

1/4" = 1'-0" 1/4" = 1'-0"

1

2

MAIN BUILDING SOUTH ELEVATION

1/4" = 1'-0"

MAIN BUILDING EAST ELEVATION

1/4" = 1'-0"

2

TRASH ENCLOSURE FRONT ELEVATION

1/4" = 1'-0"

PROPANE TANK ENCLOSURE FRONT ELEVATION

1/4" = 1'-0"

HYDROGEN DISPENSER CANOPY FRONT ELEVATION

1/4" = 1'-0"

2

21 1 1122

1

2

2

2

2

1

19'-6"

20'-4"

13'-0"

8'-2"

1

6'-0"

1

2

11

22

1

2

1

HAMILTON

MARKET PLACE

Page 13: NOTICE OF PUBLIC HEARING June 12, 2018,

19'-6"

19'-6"

19'-6"

19'-6"

13'-11"

13'-11"

13'-11"

13'-11"

HAMILTON

MARKET PLACE

Page 14: NOTICE OF PUBLIC HEARING June 12, 2018,

11

1

1 211122

2 2

2 2

22

19'-6"

19'-6"

19'-6"

19'-6"

13'-11"

13'-11"

13'-11"

13'-11"

SOUTHERN BREEZE

STONE GRAY

NEW DOORS

NEW STOREFRONT WINDOWS

(E) BRICK WALL

1

2

(E) FASCIA

(E) WINDOW

(E) ROOF

HAMILTON

MARKET PLACE

Page 15: NOTICE OF PUBLIC HEARING June 12, 2018,

2

1

SOUTH ELEVATION EAST ELEVATION

NORTH ELEVATION WEST ELEVATION

33'-4"

13'-0"

13'-0"

9'-6"

SOUTHERN BREEZE

STONE GRAY

1

2

COLOR LEGEND

13'-0"

9'-6"

1/4" = 1'-0" 1/4" = 1'-0"

1/4" = 1'-0" 1/4" = 1'-0"

2

1

2

1

2

1

2

33'-8"

33'-8"

33'-4"

HYDROGEN ENCLOSURE FLOOR PLAN

11

'-2

"

33'-0"

1/4" = 1'-0"

HAMILTON

MARKET PLACE

Page 16: NOTICE OF PUBLIC HEARING June 12, 2018,

22'-0"

19'-0" O/O CANOPY 3'-0"

8'-0" 3'-0" 3'-0" 5'-0"

22'-0"

3'-0" 19'-0" O/O CANOPY

6'-11" 2'-2" 9'-11"

20

'-0

" O

/O C

AN

OP

Y

5'-0

"1

0'-0

" C

/C C

OL

UM

NS

5'-0

"

20°

20

'-4

"

20

'-4

"

14

'-6

"5

'-1

0"

20'-0"

2'-1

1"

12

'-9

1/2

"4

'-7

9/1

6"

19

'-2

7/1

6"

4'-0"

3'-0"

45°

HAMILTON

MARKET PLACE

Page 17: NOTICE OF PUBLIC HEARING June 12, 2018,

14"

PE

R F

T. M

IN. S

LO

PE

(FLA

T R

OO

F)

D.S.

OUTLINE OFWALL BELOW

73'-4"

37'-4"

HVAC UNIT

14"

PE

R F

T. M

IN. S

LO

PE

(FLA

T R

OO

F)

HAMILTON

MARKET PLACE

Page 18: NOTICE OF PUBLIC HEARING June 12, 2018,

6'-8

"

7'-4"

18"17"-18"

RESTROOM

60" D

IA.

2

36" MIN

40

"

FLUSH ACTIVATORON WIDE SIDE

24" MIN

17

"MIN

.1

9"

MA

X.

19

"33

"

7" MIN.9" MAX,.

MIN

.

42" MIN

BA C D

NOTE:

* H0T WATER AND DRAIN PIPESUNDER LAVATORIES SHALL BEINSULATED OR OTHERWISECOVERED. THERE SHALL BE NOSHARP OR ABRASIVE SURFACESUNDER LAVATORIES.

16" min.18" max.

5'-0"

9"

EQ. EQ.

13A- SIGN SIGN

13B-

LOCKING MECHANISMCONTROLLED BY THEUSER

KICK PLATE

10"

MIN

.

1 1/4" -2"NOMINAL DIAMETER

33"-36" A.F.F.

112"

MIN.CLR.

WALL FINISH

METAL STUDBLOCKING

METAL ANGLE

34" A.F.F.

ANCHOR PLATE

112"

MIN

.C

LR

.

34"

MA

X.

27"

MIN

.

6"MAX.

9"

MIN

.

8" MIN.

17" MIN. - 25" MAX.

" M

IN.

INSULATE TRAP& HOT WATERLINES

ACCESSIBLELAVATORYFAUCET.

WALL FINISH

COVED BASE

1'-0"Ø

6"

MIN

.

6"

3"

.

6"

MIN

.

6"

3"

C D

1

A B

1'-0"

3

2

3

2

1

11B-703.6.2 FINISH AND CONTRASTPICTOGRAMS AND THEIR FIELD SHALLHAVE A NON-GLARE FINISH. PICTOGRAMSHALL CONTRAST WITH THEIR FIELDWITH EITHER A LIGHT PICTOGRAM ONA DARK FIELD OR A DARK PICTOGRAMON A LIGHT FIELD.

6"

MIN

.

8"

11B-703.4.1 HEIGHT ABOVE FINISH FLOOR.TACTILE CHARACTERS ON SINGS SHALL BE LOCATED 48" MIN. ABOVE THE FINISH FLOORMEASURED FROM THE BASELINE OF THELOWEST BRAILLE CELLS AND 60" MAX. ABOVETHE F.F., MEASURED FROM BASELINE OF THEHIGHEST LINE OF THE RAISED CHARACTERS.

48" MIN.A.F.F.

60" MAX.A.F.F.

11B-703.3.3 BRAILLE.BRAILLE SHALL CONTRACTED(GRADE 2) AND SHALL COMPLYWITH SECTION 11B-703.3 &11B-703.4

RAISED CHARACTERS SHALL BE1/32" MIN. ABOVE THEIR BACKGROUNDAND MIN. 5/8" AND MAX. 2" IN HEIGHT

DOMED DOT

6"

MIN

.

6"

10"

1"

A B

1

2

3

1

2

3

SIGNS SHALL COMPLY WITH SECTION11B-703 WHERE BOTH VISUAL AND TACTILECHARACTERS ARE REQUIRED, EITHER ONESIGN WITH BOTH VISUAL AND TACTILECHARACTERS, OR TWO SEPARATE SIGNS, ONE WITH VISUAL, AND ONE WITH TACTILECHARACTERS, SHALL BE PROVIDED.

A

B

60" A.F.F.

.059"-.063"

.025"-

.037"

.395"-

.400"

.100"

.100"

.300"

3/8

" M

IN.

3/8

" M

IN.

11B-703.3.2 POSITIONBRAILLE SHALL BE POSITIONED BELOWTHE CORRESPONDING TEXT IN AHORIZONTAL FORMAT, FLUSH LEFT ORCENTERED. IF TEXT IS MOLTI-LINED,BRAILLE SHALL BE PLACED BELOWTHE ENTIRE TEXT. BRAILLE SHALL BESEPARATED 3/8" MIN. AND 1/2" MAX.FROM ANY OTHER TACTILE CHARACTERSAND 3/8" MIN. FROM RAISED BORDERSAND DECORATIVE ELEMENTS.

48" MIN.A.F.F.

60" MAX.A.F.F.

11B-703.3.3 BRAILLE.BRAILLE SHALL CONTRACTED(GRADE 2) AND SHALL COMPLYWITH SECTION 11B-703.3 &11B-703.4

4

1

2

5 11B-703.4.2 LOCATION.WHERE A TACTILE SIGN IS PROVIDEDAT A DOOR, THE SIGN SHALL BELOCATED ALONGSIDE THE DOOR ATTHE LATCH SIDE. WHERE A TACTILESIGN IS PROVIDED AT A DOUBLE DOORS WITH ONE ACTIVE LEAF, THE SIGNSHALL BE LOCATED ON THE INACTIVELEAF. WHERE A TACTILE SIGNPROVIDED AT DOUBLE DOORS WITHTWO ACTIVE LEAFS, THE SIGN SHALLBE LOCATED TO THE RIGHT OF THERIGHT HAND DOOR. SIGNS CONTAININGTACTILE CHARACTERS SHALL BELOCATED SO THAT A CLEAR FLOOR SPACE OF 18" MIN. BY 18" MIN.,CENTERED ON THE TACTILE CHARACTERS.

5

60" A.F.F.

2

1'-0" Ø

3

HAMILTON

MARKET PLACE

Page 19: NOTICE OF PUBLIC HEARING June 12, 2018,

MERCHANDISE

RESTROOM

BACK ROOM

T

(E) ELECT.PANEL

SERVICE

#

1. -

1. -

FIXED SIDEFREE SIDE

SEISMIC CLIP

TYPICAL CEILING BRACING

HAMILTON

MARKET PLACE

Page 20: NOTICE OF PUBLIC HEARING June 12, 2018,

HAMILTON

MARKET PLACE

Page 21: NOTICE OF PUBLIC HEARING June 12, 2018,

POC

HAMILTON

MARKET PLACE