NOT ALL CATHETERS ARE CREATED EQUAL.€¦ · not all catheters . are created equal. trust...

2
NOT ALL CATHETERS ARE CREATED EQUAL. TRUST POWERWAND WWW.ACCESSSCIENTIFIC.COM [email protected] (858) 259-8333 SHOWN TO INHIBIT BACTERIAL ATTACHMENT (IN VITRO) 1 SHOWN TO REDUCE THROMBUS FORMATION (IN VIVO) 2 OVER 35,000 CATHETER DAYS WITH ZERO BSIs FAST AND EASY INSERTION ONE STICK HOSPITALIZATION UNPARALLELED POWER INJECTION PERFORMANCE (8ML/SEC, 325 PSI) KINK RESISTANCE HIGH FLOW (130-180 ML/MIN) BLOOD DRAWABILITY

Transcript of NOT ALL CATHETERS ARE CREATED EQUAL.€¦ · not all catheters . are created equal. trust...

Page 1: NOT ALL CATHETERS ARE CREATED EQUAL.€¦ · not all catheters . are created equal. trust powerwand. cs@accessscientific.com (858) 259-8333. shown. to inhibit bacterial attachment

NOT ALL CATHETERS ARE CREATED EQUAL.

TRUST POWERWAND

WWW.ACCESSSCIENTIFIC.COM [email protected] (858) 259-8333

SHOWN TO INHIBIT BACTERIAL ATTACHMENT (IN VITRO)1

SHOWN TO REDUCE THROMBUS FORMATION (IN VIVO)2

OVER 35,000 CATHETER DAYS WITH ZERO BSIs‡

FAST AND EASY INSERTION ONE STICK HOSPITALIZATION

UNPARALLELED POWER INJECTION PERFORMANCE (8ML/SEC, 325 PSI)

KINK RESISTANCE HIGH FLOW (130-180 ML/MIN) BLOOD DRAWABILITY

Page 2: NOT ALL CATHETERS ARE CREATED EQUAL.€¦ · not all catheters . are created equal. trust powerwand. cs@accessscientific.com (858) 259-8333. shown. to inhibit bacterial attachment

THE POWERWAND – A CATHETER WITHOUT EQUAL.

Blood Drawability:60-99%‡ blood drawability

for full length of stay

Infection Prevention:Zero BSIs over 35,000 catheter-days (and counting)‡

Catheter material: ChronoFlex C® with BioGUARD™ Technology is proven to inhibit bacterial attachment (in vitro)1

High Flow:Highest flow rates of any midline

catheter: up to 180 mL/min

Power Injection:The best power injection

performance rating on the market: 8mL/sec, 325 psi

BioGUARD™ Technology70% reduction

in bacterial attachment¹

Polyurethane*

Clean:POWERWAND is shown to inhibit bacterial attachment (in vitro)1 and is thromboresistant2

Kink Resistant:Unlike other catheters, the unique material of the POWERWAND catheter is highly kink resistant, allowing for reliability during both insertion and dwell time

POWERWAND material

Standard catheter material

POWERWAND Catheter

Trimmed Catheter

Non-Trimmable:No trimming means a reduction in DVTs‡; there are no jagged edges on the thermoformed POWERWAND catheter 1. Proven in vitro to significantly (p=0.0133) inhibit bacterial attachment and biofilm

formation† as compared with a commonly used polyurethane catheter*.2. The POWERWAND is proven in vivo to be thromboresistant with respect to both thrombuson the surface of the catheter and thrombus on the wall of the vein. Based on canine jugularvein thromboresistance study, correlations to clinical applications has not been ascertained.† Based on laboratory test results which may not be indicative of clinical results. Data on file

and refer to publication³. Preclinical in-vitro evaluations do not necessarily predict clinicalperformance with respect to catheter-related bloodstream infection.

3. Pathak R, Bierman S, d’Arnaud P. Inhibition of bacterial attachment and biofilm formation bya novel intravenous catheter material using an in vitro percutaneous catheter insertion model.

Medical Devices: Evidence and Research. 2018;11:1-6.https://doi.org/10.2147/MDER.S183409.

4. Moureau N, Sigl G, Hill M. How to Establish an Effective Midline Program: A Case Study of 2 Hospitals. JAVA 2015; 20(3):179-188.

5. Pathak R, Patel A, Enuh H, et al. The Incidence of Central Line–Associated Bacteremia After the Introduction of Midline Catheters in a Ventilator Unit Population.

Infect Dis Clin Prac 2015;23(3): 131-134.

* PowerGlide® (CR Bard, Salt Lake City, UT) - a registered trademark of C.R. Bard.

POWERWAND™ and BioGUARD™ are trademarks of Access Scientific, LLC.

ChronoFlex C® is a registered trademark of AdvanSource Biomaterials Corp.‡Data on File.

Echogenic:Echogenic properties of

POWERWAND catheter allows for ultrasound visualization once in the vein

Cost Savings:Due to its performance, the POWERWAND resulted in an estimated $448,000-$531,570 of annual savings4, 5

100 µm 100 µm

LC-0392 Rev. F