113459743 TCVN 7336 2003 Fire Protection Automatic Sprinkler System En
Northern AB no prices-2016 - Inland Pipeinlandpipe.com/sites/inlandpipe.com/files/PDFs... · Fax:...
Transcript of Northern AB no prices-2016 - Inland Pipeinlandpipe.com/sites/inlandpipe.com/files/PDFs... · Fax:...
INLA
ND
PIPE
Working together to build our communities ®
Inland Pipe Contacts
ABOUT INLANDInland roots in the Calgary area date back to the early 1900’s. Overtime, through a number of mergers and acquisitions Inland Pipe isnow part of the Lehigh Hanson group in North America and part ofthe world-wide HeidelbergCement Group.
HeidelbergCement is the global market leader in aggregates and a prominent player in the fields of cement, concrete and otherdownstream activities, making it one of the world’s largestmanufacturers of building materials. The company employs some52,000 people at 2,500 locations in more than 40 countries.
Robert Powers, CET 780-448-1351 Manager, Northern Alberta & Ocean Pipe Sales and [email protected]
Tony Genge, CET
780-448-1351Senior Technical [email protected]
Wayne Timm, CET
780-448-1351Sales Representative & Safety [email protected]
780-448-1351Technical Sales Representative
Adam Richards
Distribution [email protected]
Brenda Smith
780-448-1351Administrative [email protected]
Main Line
Fax
Calgary Office
Winnipeg Office
Vancouver Office
Notes:
780-448-1351
780-448-1351
780-448-1354
403-279-5531
204-334-4300
604-269-6700
Prices effective January 31, 2016.
Morgan Howard, EIT
Tyson Dyck, EITTechnical Marketing & [email protected]
Saskatchewan Office 306-209-5618
Inland Pipe and our our sister company Ocean Pipe (British Columbia)combine to form the largest producer of concrete pipe andmanholes in Western Canada.Our automated Spyhill facility in Calgary, Alberta is the most advancedprecast drainage facility in North America.
780-448-1351
New Product Application ..................................................................... 2
Three Sided Boxes / Utility Trays ............................................................ 3
Plant Prequalification ........................................................................ 5
Pipe Fill Heights Estimation Table............................................................ 6
Concrete Pipe .................................................................................... 7
Flared Ends ....................................................................................... 8
Prefabrication Bends ........................................................................... 9
Curved Alignment Reference Table ......................................................... 9
Plugs/Caps/Adaptors ........................................................................... 10
Tee Risers ....................................................................................... 11
Manhole Material - Standard 1200mm Diameter ....................................12 & 13
Manhole Material - Standard 1200mm Diameter - Estimation Table .................. 14
Prebench Bases ................................................................................. 15
Catch Basin Material - 600mm Diameter ................................................... 16
Catch Basin Material - 750mm Diameter ................................................... 17
Catch Basin Material - 900mm Diameter ................................................... 18
Slab Tops.......................................................................................... 19
Manhole Material - Large Diameter ...................................................20 & 21
Box Sections ..................................................................... 22 & 23 & 24
Miscellaneous ................................................................................. 25
Terms/Freight Gudelines........................................................................ 26
Swift Life Procedures .....................................................................27 & 28
Swift Lift - Clutch & Pins ...............................................................29 & 30
Superseal Gaskets .............................................................................. 31
Standard Installations ........................................................................ 32
New Product Applications
Working together to build our communities®Working together to build our communities®
A(mm)
2955
2955
PIPE DIAMETER(mm)
1500 - 1800
1950 - 2400
TYPE
26-28
26-28
B(mm)
4186
4186
C(mm)
2540
3226
D(mm)
1421
2107
E(mm)
406
406
3660 x 3660mm Box Culvert
Inland Pipe’s 3660 x 3660mm box culvert can be used for a number of applications.Box sections can be used horizontally for culverts or storm water detention tanks and verticallyfor manholes, control structures and lift stations. See our box culvert section for more details.
Headwalls Inland Pipe can now provideHeadwall structures for large diameter pipe in Alberta.
Please contact your Inland Piperepresentative for moreinformation.
22016 Catalogue INLAND PIPE | Tel: 780 448 1351www.inlandpipe.com |
W W
BOTTOM WALL
TOP WALL
SPAN
RISE
PIPE DIAMETER
A
D
E
C
B
32016 Catalogue
Working together to build our communities®Working together to build our communities®
Three Sided Boxes / Utility Trays
Three Sided Boxes / Utility Trays Applications:Inland Pipe is now offering three sided boxes which can be used on various applications where the lid is required to be installed after the boxes. This allows utilities, power cables, or other contents to be installed and then covered with the matching lids.Sizes Available:
Design:Three sided boxes can be designed to work in most installations. All designs are completed in
Pricing:Please contact your local sales repr sentative for pricing.
REMOVABLE LID
THREE SIDED BOX CULVERT
Isometric view
Cross sectional view
INLAND PIPE | Tel: 780 448 1351 www.inlandpipe.com|
SASKATCHEWANINLAND PIPEPo. Box 306,Hwy #1E.Regina, SK S4P 3A1Tel: 306 209 5618Fax: 306 789 7499
EDMONTONSales Office & Distribution Yard12250 170 Street N.W.Edmonton, Alberta T5W 1L7Tel: 780 448 1351Fax: 780 448 1354
CALGARYSpyhill Production Plant & Sales Office7336 112 Avenue N.W.Calgary, Alberta T3R 1R8Tel: 403 279 5531Fax: 403 279 7648Toll Free: 1 800 268 0785
WINNIPEGProduction Plant & Sales Office2494 Ferrier Street, P.O. Box 4080RPO Redwood CentreWinnipeg, Manitoba R2W 5K8Tel: 204 334 4300Fax: 204 334 7957Toll Free: 1 877 WPG PIPE (974 7473)
FOUR OFFICES IN WESTERN CANADA TO SERVE YOU
52016 Cataloguewww.inlandpipe.com|
This stamp means Quality . It signifies that your precast concrete drainageproduct has met the stringent demands of the Plant Prequalification Program.
The INLAND PIPE Calgary Plant has consistently achieved and maintained its Prequalification,and is currently certified to provide precast concrete pipe, manholes and box sections under theProgram.
What does Prequalification mean?
Owners of infrastructure projects, who purchase precast concrete drainage products fromprequalified plants, receive products that have been tested for quality through the manufacturingprocess and inspected upon completion. Concrete drainage products supplied from a prequalifiedplant comply with the requirements of the latest editions of the following specifications:
• CSA A257.0 / ASTM C497 - testing procedures for precast drainage materials• CSA A257.1 / ASTM C14 - non-reinforced concrete pipe• CSA A257.2 / ASTM C76 - reinforced concrete pipe• CSA A257.3 / ASTM C443 - joints for precast drainage materials• CSA A257.4 / ASTM C478 - precast reinforced manhole sections• CSA S6-06 / ASTM C1433 - precast reinforced box culvert sections
ACHIEVING AND MAINTAINING PREQUALIFICATION:
A consulting engineer is retained to carry out an independent inspection of the applicant’s plantand product. Samples of products are tested and the engineer submits a detailed report to thethird party consultant. This report to the Chair states a compliance, or noncompliance with the prequalification requirements, together with a recommendation. The Chair issues the PrequalificationCertificate.
The Certificate states the Product to which the prequalification applies and is normally valid for12 months after the date of issue.
Each year, plants are inspected by the engineer who checks and tests to ascertain whether or notquality control and the standard of workmanship is being maintained at a satisfactory level. Everythird year, the engineer undertakes detailed inspection and testing, and submits a report compa-rable to the original inspection for prequalification.
Quality control personnel within the precast concrete manufacturing facilities receive regulartraining, provided by the manufacturer, to ensure the quality control processes are performedcorrectly by the staff, and the information gathered is analyzed and maintained in accordancewith the program.
Plant Prequalification Program
6 2016 Catalogue
31
www.inlandpipe.com |
Working together to build our communities®
INLAND PIPE | Tel: 780 448 1351 7Concrete Pipe
250
300
375
450
525
600
675
750
900
1050
1200
1350
1500
1650
1800
1950
2100
2400
2700
3000
10”
12”
15”
18”
21”
24”
27”
30”
36”
42”
48”
54”
60”
66”
72”
78”
84”
96”
108”
120”
1.25
2.50
2.50
2.50
2.50
2.50
2.50
2.50
2.50
2.50
2.50
2.50
2.50
2.50
2.50
2.50
2.50
2.50
2.50
2.50
2.50
112
197
263
336
417
506
603
708
942
1207
1503
1832
2192
2583
3006
3461
3948
5015
6210
7010
254
305
381
457
533
324
445
533
622
711
800
428
508
606
702
803
37
70
76
83
89
(mm)
NOMINALINSIDE DIA.
LGTH.
(in.) (m) (kg/m) A B C D
WGT.
51
73
114
164
223
292
370
456
656
894
1167
1478
1824
2206
2627
3082
3577
4668
5909
7297
(L/m)
VOL. ASTMC-14CL-3
EST. CITYCARTAGE
($/m)ASTM C76, CL-5
CSA 257.2 140-D
PRICES per METRE
REINFORCED PIPEDIMENSIONS (mm)
A B C D
EST. CITYCARTAGE
($/m)CL-250-D
CL-365-D
CL-4100-D
CL-5140-D
REINFORCED PIPE (CSA 257.2, ASTM C76)
(mm)
NOMINALINSIDE DIA.
(in.)
LGTH.
(m) (kg/m)
WGT.
(L/m)
VOL. ASTMC-14CL-3
E63
90
90
95
95
EDIMENSIONS (mm)
-
-
-
-
-
• 300mm to 2100mm single offset joint design with self lubricating (Superseal) gasket• 2400mm to 3000mm single offset joint design with manually lubricated gasket• Radius Pipe available; add 15% to list prices• Direct Design pipe (ASTM C1417, ASCE 15-98) available; call for details and pricing
• Pipe sizes over 900mm are not typically stocked; please call for availability• The City Cartage is intended as an estimating guide only • Straight Wall and Jacking Pipe available, call for pricing
HIGH SULFATE RESISTANT CEMENT - ASTM C76
2016 Catalogue
www.inlandpipe.com|
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
610
686
762
914
1067
1219
1372
1524
1676
1829
1981
2134
2438
2743
3048
800
889
978
1156
1334
1511
1689
1867
2045
2223
2400
2578
2934
3289
3607
905
1006
1038
1229
1461
1514
1692
1870
2048
2226
2400
2578
2934
3289
3607
95
102
108
121
133
146
159
171
184
197
210
222
229
273
279
98
98
98
98
108
108
108
121
127
127
127
127
127
149
152
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
NOMINALDIAMETER
(mm)
LENGTH(mm)
WEIGHT(kg/ea.)
PRICE($/ea.)
EST. CITYCARTAGE
($/ea.)w/ NO GATE
($/ea.)w/ GATE($/ea.)
300
375
450
525
600
675
750
900
1050
1200
*1350
*1500
1854
1854
1854
1867
1867
1873
1873
2438
2489
2489
2545
2450
570
780
1010
1465
1465
1800
1800
3390
4660
4490
3665
3980
GALVANIZED ROUND GRATES
* Products are resale items• Available as either Bell or Spigot• Flared ends larger than 1500mm diameter are available; call for estimate• 525mm is a modified 600mm; 675mm is a modified 750mm• End slope varies; call for details
Working together to build our communities®
INLAND PIPE | Tel: 780 448 1351
Flar
ed
Ends
ACTUAL INSIDEDIAMETER
(mm)
C(mm)
W(mm)
L(mm)
305
381
457
533
610
762
914
1067
1219
*1372
*1524
A(mm)
B(mm)
102
152
229
241
241
305
381
533
610
685
760
610
686
686
1105
1105
1372
1600
1600
1829
1650
1525
1245
1168
1168
762
762
502
838
889
660
895
820
610
762
914
1219
1219
1524
1829
1981
2134
2545
2740
1854
1854
1854
1867
1867
1873
2438
2489
2489
2545
2450
8 2016 Catalogue www.inlandpipe.com |
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Working together to build our communities®
9Prefabricated
Bends
EST. CITYCARTAGE
($/ea.)DESCRIPTION
Nominal Diameter (mm)
CL-450D - 100D
PRICE ($/ea.)
CL-5101D - 140DPRICE ($/ea.)
WEIGHT(kg/ea.)
30037545052560067575090010501200135015001650180019502100
400550725975105512701600216029003400381047405620656574509000
• Available in angles up to 90° in 5° increments• Bends larger than 2100mm diameter are available; call for estimate
HIGH SULFATE RESISTANT CEMENT - ASTM C76
SIZE(mm)
30037545052560067575090010501200135015001650180019502100240027003000
ACTUAL ID(mm)
30538145753361068676291410671219137215241676182919812134243827483048
WALLTYPE
CCCCCCCCCCCCCCCCCCB
WALLDEPTH(mm)
7076838995102108121133146159172184197210222248274279
PIPE OD(mm)
445534622711801889978115513341511169018672044222324002579293332953607
DROP (m)
MINIMUM RADIUS ACHIEVABLE (TIGHTEST CURVE)
58.269.781.392.9104.7116.3127.9151.0174.4197.6220.9244.1267.3290.6313.8337.1383.5430.8471.5
PULL (m)
85.5102.6119.6136.7154.0171.0188.1222.2256.5290.6324.9359.0393.1427.5461.6495.9564.1633.7693.6
COMBO (m)
34.741.648.555.462.469.476.390.1104.0117.9131.8145.6159.5173.4187.2201.1228.8257.0281.3
PIPE LENGTH (mm) STANDARD 2500mm RADIUS PIPE (mm) MAX DROP 0.75" DEFLECTED STRAIGHT PIPE (mm) MAX PULL 13mm
INLAND PIPE | Tel: 780 448 1351 2016 Cataloguewww.inlandpipe.com|
----------------
----------------
----------------
250
300
375
450
525
600
675
750
900
1050
1200
1350
1500
1650
1800
1950
2100
240027003000
30
30
45
70
90
150
175
200
250
500
700
900
1400
1600
1800
2200
3500
397352706500
DESCRIPTIONNOMINAL DIAMETER (mm)
WEIGHT(kg/ea.)
PRICE($/ea.)
EST. CITY CARTAGE($/ea.)
• Plugs for Bell application• Caps for Spigot application
HIGH SULFATE RESISTANT CEMENT
10 2016 Catalogue www.inlandpipe.com |
--------------------
--------------------
Working together to build our communities®
INLAND PIPE | Tel: 780 448 1351 11Tee Risers
DESCRIPTIONNominal Diameter (mm) x Length (m)
CL-450D - 100D
PRICE ($/ea.)
CL-5101D - 140DPRICE ($/ea.)
WEIGHT(kg/ea.)
HEIGHT(mm)
EST. CITYCARTAGE
($/ea.)
1050 x 2.5
1200 x 2.5
1350 x 2.5
1500 x 2.5
1650 x 2.5
1800 x 2.5
1950 x 2.5
2100 x 2.5
2400 x 2.5
2700 x 2.5
3000 x 2.5
4325
4500
5000
5310
6100
7100
8200
9500
11850
14800
18050
1633
1786
2098
2258
2418
2583
2743
2908
3338
3638
4088
HIGH SULFATE RESISTANT CEMENT - ASTM C76
• 1200 Tee Risers with Adaptors may be used in straight thru applications for 675mm to 900mm pipe.• See page 10 for Adaptor pricing.
2016 Cataloguewww.inlandpipe.com|
635mm
1219mm1219mm
635mm
HEIGHT
1200mmMANHOLEMATERIAL
1050mmTO
3000mm
REDUCER INCREASER
DIRECTIONOF FLOW
SIDE VIEW TYPICAL TEE RISER SECTION
-----------
-----------
-----------
Working together to build our communities®
INLAND PIPE | Tel: 780 448 135112
Man
hole
Mat
eria
l
1200mm Base (Round)
1200mm x 2.0m M.H. Barrel
1200mm x 1.20m M.H. Barrel
1200mm x 0.80m M.H. Barrel
1200mm x 0.41m M.H. Barrel
1200mm x 0.30m M.H. Barrel
1200mm x 0.91m Conical Top
1200mm Slab Top w/ 635mm Hole M.J.
1200mm Slab Top w/ 914mm Hole M.J.
T-Top
E-Top
DK-7 Top
1200mm Bell-Bell or Spigot-Spigot Adaptor Barrel
710
2730
1585
1050
525
396
1370
753
553
350
300
200
525
EST. CITYCARTAGE
($/ea.)
PRICE($/ea.)
WEIGHT(kg/ea.)
1200mm NOMINAL DIAMETER(RUBBER GASKET JOINT)
HIGH SULFATE RESISTANT CEMENT - ASTM C478
• Superseal self lubricated rubber gaskets are provided with above barrels. Bituminous joint sealant also available see page 25• Refer to page 19 for Slab Top reference drawings• Approximate volume capacity is 1167 L/m
EST. CITYCARTAGE
($/ea.)
WEIGHT(kg/ea.)
PRICE($/ea.)
GRADE RINGS
635mm INSIDE DIAMETER
50mm Grade Ring (24 Rings/Pallet)
75mm Grade Ring (16 Rings/Pallet)
100mm Grade Ring (12 Rings/Pallet)
150mm Grade Ring (8 Rings/Pallet)
914mm INSIDE DIAMETER
75mm Grade Ring (16 Rings/Pallet)
100mm Grade Ring (8 Rings/Pallet)
50
65
70
110
140
180
Edmonton Pipe Yard on 149 StreetPhoto taken in May, 1958
2016 Catalogue www.inlandpipe.com |
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
2016 Catalogue 13www.inlandpipe.com |
SWIFT LIFTLIFTING PIN
635mm
CONICAL TOP(HEIGHT = 910mm)
BARRELSAVAILABLEIN SIZES:2000mm1200mm800mm410mm300mm
200mm
200mm
108mm
108mm
635
914
127mm
1219mm
410 400194 616
200
SINGLE OFFSETJOINT WITH SELF
LUBRICATINGGASKET
ALUMINUMLADDER RUNG
FLAT BASE (ROUND)(ALTERNATIVE TO PREBENCH BASES)
SLAB TOP WITH635mm HOLE
SLAB TOP WITH914mm HOLE
SPIGOT - SPIGOT ADAPTOR BELL - BELL ADAPTOR
LADDER RUNGS@ 400mm O.C.
BENCHING @ 10°
GRADE RINGS
FRAME & COVER
PREBENCH BASE(SEE PREBENCH SECTION)
TYPICAL 1200mm MANHOLE CONFIGURATION
1.50
1.60
1.70
1.80
1.90
2.00
2.10
2.20
2.30
2.40
2.50
2.60
2.70
2.80
2.90
3.00
3.10
3.20
3.30
3.40
3.50
3.60
3.70
3.80
3.90
4.00
4.10
4.20
4.30
4.40
4.50
4.60
4.70
4.80
4.90
5.00
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
1
1
1
2
1
2
2
3
1
1
1
1
1
1
1
1
1
1
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
2
1
1
1
1
1
2
2
1
1
1
1
2
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
DEPTH(m)
HEIGHT OF MANHOLE BARRELS (m)
2.00 1.20 100mm 75mm
FRAME&
COVER
EST.TOTAL
COST ($)
EST.TOTAL
WGT. (kg)0.80 0.41
CONICALTOP
0.91m
SLABTOP
200mm 150mm
GRADE RINGS
The table is based on the following parameters:• Depth is the difference from rim elevation to lowest pipe invert elevation• Prebench base with an effective height 0.80m• Standard prebench base for 300mm diameter pipe applied to the estimated total cost• Slab top with a 635mm opening applied to the estimated total cost• Standard frame and cover height of 150mm
0.30
1
2
2
1
1
1
2
1
1
1
1
2
1
2
1
2
1
2
1
PREBENCHBASE
Working together to build our communities®
INLAND PIPE | Tel: 780 448 135114
Man
hole
Mat
eria
l2016 Catalogue www.inlandpipe.com |
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
3,423
3,679
3,808
3,878
4,075
4,145
4,274
4,040
4,296
4,366
4,455
4,692
4,821
4,886
4,980
5,050
5,346
5,416
5,540
5,610
5,812
5,951
6,075
6,145
6,347
6,471
6,600
6,670
6,867
7,096
7,220
7,290
7,492
7,616
7,710
7,790
Working together to build our communities®
INLAND PIPE | Tel: 780 448 1351 15
STANDARDPRICE ($/ea.)
SPECIALPRICE ($/ea.)
EST. CITYCARTAGE
($/ea.)
150
200
250
300
375
450
525
*600
**MONOBASE
705
775
775
860
860
970
970
1065
1065
1930
2100
2100
2280
2280
2510
2510
2460
2285 n/a
HEIGHT FROM INVERTCONCRETE PIPE
(mm)
WEIGHTCONCRETE PIPE
(kg/ea.)
HIGH SULFATE RESISTANT CEMENT - ASTM C478
• Standard Base: Pipe openings at 90 degrees or multiples thereof• Special Base: Pipe openings not at 90 degrees or multiples thereof, or not standard slope• Drawings required for manufacture* Available only for straight through configurations** The monobase is without any opening
LARGEST NOMINALPIPE DIAMETER
(mm)
PrebenchBases
2016 Cataloguewww.inlandpipe.com|
EFFECTIVEHEIGHT
1219mm
SECTION VIEW
LE
NN
AH
C W
OLF
TOP VIEW
108mm
n/a
---------
-------
---------
Working together to build our communities®
INLAND PIPE | Tel: 780 448 135116Ca
tch
Basi
nM
ater
ial 6
00m
m2016 Catalogue www.inlandpipe.com |
500mmSUMP
SEE ABOVE FORHOLE OPTIONS
635mmGRADE RINGS
105mm
500mm
610mm
1830mm
150mm K-7 TOP
635mm635mm
533mm150mm
TYPICAL 600mmCATCH BASIN WITH
635 EXTENSION RINGS
TYPICAL 600mmCATCH BASINWITH K7 TOP
525 TOP
1134
EST. CITYCARTAGE
($/ea.)
PRICE($/ea.)
WEIGHT(kg/ea.)
600mm NOMINAL DIAMETER(MORTAR JOINT)
50
65
70
110
• Refer to page 19 for Slab Top reference drawings• Rub-R-Nek (Kent Seal) is extra and NOT included in the above pricing; refer to page 25 for details.
HIGH SULFATE RESISTANT CEMENT
150
150
HOLE OPTIONS PIPE
1134
1134
1134
1134
-
-
-
-
-
-
-
-
-
-
-
600mm x 1.83m C.B.Barrel c/w Base and Hole 375mm Partial knockout Any
600mm x 1.83m C.B.Barrel c/w Base and Hole 300mm Rough Cut Hole 200mm Ultra-Rib
600mm x 1.83m C.B.Barrel c/w Base and Hole 375mm Rough Cut Hole 250mm Ultra-Rib
600mm x 1.83m C.B.Barrel c/w Base and Hole 300mm (12") core c/w boot 200mm SDR
600mm x 1.83m C.B.Barrel c/w Base and Hole 400mm (16") core c/w boot 250mm SDR
K7 Top
525 Top
635mm I.D. x 50mm Grade Ring
635mm I.D. x 75mm Grade Ring
635mm I.D. x 100mm Grade Ring
635mm I.D. x 150mm Grade Ring
-
-
-
-
-
-
-
-
-
-
-
Working together to build our communities®
INLAND PIPE | Tel: 780 448 1351 17
EST. CITYCARTAGE
($/ea.)
PRICE($/ea.)
WEIGHT(kg/ea.)
750mm NOMINAL DIAMETER(MORTAR JOINT)
Catch BasinM
aterial 750mm
• Refer to page 19 for Slab Top reference drawings• Rub-R-Nek (Kent Seal) is extra and NOT included in the above pricing; refer to page 25 for details.
HIGH SULFATE RESISTANT CEMENT
2016 Cataloguewww.inlandpipe.com|
750mm x 1.85m C.B. Barrel c/w Base & Hole
750mm x 1.22m C.B. Barrel c/w Base & Hole
750mm x 1.22m C.B. Barrel
750mm x 0.61m C.B. Barrel c/w Base
750mm x 0.61m C.B. Barrel
750mm Slab Top
K7 Top
1225
845
725
565
366
175
150
-
-
-
-
-
-
-
-
-
-
-
-
-
-
635mm150mm
762mm
89mm
500mmSUMP
750mm x1.85mw/ BASE & RCH SIZEUP TO 375mm DIA.
150mm K7 TOP
635mm80mm
635mm GRADERINGS
750mm SLAB TOP
750mm x 1.22mw/ BASE & HOLE
OR0.61m BARRELw/ BASE ONLY
BARRELSAVAILABLE IN SIZES:
1.22m0.61m
TYPICAL 750mmCATCH BASIN WITH
635mm EXTENSION RINGS
TYPICAL 750mmCATCH BASIN WITH
K7 TOP
100mm
Working together to build our communities®
INLAND PIPE | Tel: 780 448 135118
• Refer to page 19 for Slab Top reference drawings• Rub-R-Nek (Kent Seal) is extra and NOT included in the above pricing; refer to page 25 for details.
Catc
h Ba
sin
Mat
eria
l 900
mm
2016 Catalogue www.inlandpipe.com |
*Also available with steps
914mm
TYPICAL 900mmCATCH BASIN WITH EITHERT-TOP, E-TOP, OR DK-7 TOP
914mm SLABTOP w/900mm OPENING
914mm GRADE RINGS
500mmSUMP
T-TOP (SHOWN),E-TOP, or DK-7 TOP
2055mm
102mm
SEE ABOVE FORHOLE OPTIONS
150mm
150mm
635mm
635mm GRADE RINGS
900mm SLAB TOPw/ 635mm OPENING
900mm x 0.46mBARREL
(w/ OPTIONAL RUNGS)
900mm x 1.22mBARREL
(w/ OPTIONAL RUNGS)
TYPICAL 900mmCATCH BASIN
WITH SEPARATE BASE
500mmSUMP
EST. CITYCARTAGE
($/ea.)
PRICE($/ea.)
WEIGHT(kg/ea.)
900mm NOMINAL DIAMETER(MORTAR JOINT)
HIGH SULFATE RESISTANT CEMENT
900mm Base
900mm x 1.85m C.B. Barrel c/w Base & Hole
900mm x 1.22m C.B. Barrel c/w Base & Hole
900mm x 1.22m C.B. Barrel
900mm x 0.46m C.B. Barrel
900mm Slab Top w/ 635mm Hole
900mm Slab Top w/ 914mm Hole
T-Top
E-Top
DK-7 Top
GRADE RINGS (914mm I.D.)
75mm Grade Ring
100mm Grade Ring
450
1870
1233
1005
357
300
120
350
300
200
140
180
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
192016 Cataloguewww.inlandpipe.com|
750mm TO 1200mm SLAB TOP w/ 635mm HOLE
9
26B
200635
1200mm SLAB TOPw/ 635mm OPENING
Ø1473
Ø635
Ø1219
1200mm SLAB TOPw/ 914mm OPENING
200914
Ø1473
Ø1219
Ø914
260635
900mm SLAB TOPw/ 635mm OPENING
Ø1118Ø914
Ø635
260914
900mm SLAB TOPw/ 914mm OPENING
Ø1118
Ø914
E-TOP
Ø1118Ø914
600400
DK-7 TOP
Ø1118Ø914
895
495
600
150
495
T-TOP
Ø1118Ø914
225
600
400
776
200
150
750mm SLAB TOPw/ 635mm OPENING
Ø940
Ø762
Ø635
635
150150
K7 TOP
500430
Ø889
150
500
525 TOP
150
Ø889
Ø533
914mm GRADE RINGS 635mm GRADE RINGS
100
75914
Ø1118
Ø914
150
100
75
50
Ø889
Ø635
635
• Add 10% to standard slab top price for a slab top adaptor • Large diameter manhole material is NOT stock material; call for availability
1500mm x 2.5m M.H. Barrel1500mm x 2.0m M.H. Barrel1500mm x 1.8m M.H. Barrel1500mm x 1.5m M.H. Barrel1500mm x 1.2m M.H. Barrel1500mm x 0.6m M.H. Barrel
1500mm Slab Top1500mm Base
1800mm x 2.5m M.H. Barrel1800mm x 2.0m M.H. Barrel1800mm x 1.8m M.H. Barrel1800mm x 1.5m M.H. Barrel1800mm x 1.2m M.H. Barrel1800mm x 0.6m M.H. Barrel
1800mm Slab Top1800mm Base
2100mm x 2.5m M.H. Barrel2100mm x 2.0m M.H. Barrel2100mm x 1.8m M.H. Barrel2100mm x 1.5m M.H. Barrel2100mm x 1.2m M.H. Barrel2100mm x 0.6m M.H. Barrel
2100mm Slab Top2100mm Base
2400mm x 2.5m M.H. Barrel2400mm x 2.0m M.H. Barrel2400mm x 1.8m M.H. Barrel2400mm x 1.5m M.H. Barrel2400mm x 1.2m M.H. Barrel2400mm x 0.6m M.H. Barrel
2400mm Slab Top2400mm Base
2700mm x 2.5m M.H. Barrel2700mm x 2.0m M.H. Barrel2700mm x 1.8m M.H. Barrel2700mm x 1.5m M.H. Barrel2700mm x 1.2m M.H. Barrel2700mm x 0.6m M.H. Barrel
2700mm Slab Top2700mm Base
3000mm x 2.5m M.H. Barrel3000mm x 2.0m M.H. Barrel3000mm x 1.8m M.H. Barrel3000mm x 1.5m M.H. Barrel3000mm x 1.2m M.H. Barrel3000mm x 0.6m M.H. Barrel
3000mm Slab Top3000mm Base
54804384394632882630131515251685
75156012541145093607180422702405
98707896710659224738236931553225
1253810030902775236018300941654185
15525124201117893157452372653005270
175251402012618105158412420665756480
DESCRIPTION OF ITEMS(NOMINAL DIAMETER)
WEIGHT(kg/ea.)
456036483283273621891094
--
656852554729394131531576
--
894271536438536542922146
--
1167193378403700256022801
--
147731181910637886470913546
--
1824114593131341094587564378
--
VOLUME(L/barrel)
PRICE($/ea.)
EST. CITY CARTAGE($/ea. or v.m.)
Larg
e Di
a.M
anho
les
1500mm DIAMETER MATERIAL
1800mm DIAMETER MATERIAL
2100mm DIAMETER MATERIAL
2400mm DIAMETER MATERIAL
2700mm DIAMETER MATERIAL
3000mm DIAMETER MATERIAL
Working together to build our communities®
INLAND PIPE | Tel: 780 448 135120 2016 Catalogue INLAND PIPE | Tel: 780 448 1351
HIGH SULFATE RESISTANT CEMENT - ASTM C478
www.inlandpipe.com |
--------
--------
--------
--------
--------
--------
--------
--------
--------
--------
--------
--------
Working together to build our communities®
INLAND PIPE | Tel: 780 448 1351 21
BITUMINOUS JOINT SEALANT (KENT SEAL) REQUIRED per JOINT
NOMINAL DIAMETEROF MANHOLE
SEALANT COILSIZE
COILSper JOINT
APPROX. COSTper JOINT
1500mm
1800mm
2100mm
2400mm
2700mm
3000mm
1.5" THICK X 10.5' LONG
1.5" THICK X 10.5' LONG
1.5" THICK X 10.5' LONG
1.5" THICK X 10.5' LONG
1.5" THICK X 10.5' LONG
1.5" THICK X 10.5' LONG
2
3
3
3
4
4
-
-
-
-
-
-
LDMH DIMENSIONAL DETAILDIAMETER
(mm)WALL
THICKNESS“T” (mm)
SLAB TOPTHICKNESS“S1” (mm)
SLAB TOPEFF. HGT.
“S2” (mm)
BASETHICKNESS“B” (mm)
171
197
222
248
273
279
280
280
280
280
280
280
SPIGOTLENGTH
“C” (mm)121
127
127
127
149
152
Large Dia.M
anholes2016 Cataloguewww.inlandpipe.com|
635mm 635mm
1524mm TO 3028mm
1524mm TO 3048mmL.D.M.H.MATERIAL
1200mmMANHOLEMATERIAL
S2
CB
1219mm
BARRELSAVAILABLEIN SIZES:2500mm2000mm1800mm1500mm1200mm600mm
BC
S2
S1
S1
T
T
VARIES
SLAB TOP
SWIFT LIFT PIN
LADDER RUNGS@ 400mm O.C.
BASE
LADDER RUNGS@ 400mm O.C.
ADAPTOR
SWIFTLIFT PIN
TYPICAL LARGE DIAMETER MANHOLECOMBINED WITH 1200mm M.H. MATERIAL
TYPICAL LARGE DIAMETER MANHOLE
1524
1829
2134
2438
2743
3048
305
305
305
305
305
305
426
432
432
432
454
457
Working together to build our communities®
INLAND PIPE | Tel: 780 448 135122
• Additional box sizes available; call for details• Prices shown are intended only as an estimating guide; detailed quotations are available upon request• Pricing assumes reinforcement design to CHBDC CSA-S6-06 with CL-800 loading. For other loading conditions, call for estimate.• Add 10% to standard slab top price for a slab top adaptor• Box material is NOT stock material; call for availability• Vertical box application to maximum depth of 10m• Rough cut, cored holes and rake out sections extra; call for pricing• Bend and beveled end sections produced with 2.5m box length (all sizes except 3600 x 3600, which uses a 1.8m box length)
Box
Sect
ions
2016 Catalogue
• Box sections manufactured to ASTM C1433 Standard, using sulfate-resistant cement.
DESCRIPTION OF ITEMS(SPAN x RISE x LENGTH)
VOLUME(L/box)
PRICES per ITEM
ASTM C1433COVER RANGE1.0m - 3.5m
(HORIZONTAL INSTALL)
ASTM C1443COVER RANGE3.5m - 7.0m
(HORIZONTAL INSTALL)
ASTM C1443COVER RANGE
7.0m - 9.0m (HORZ. INST.)0.0m - 1.0m(VERT. OR HORZ. INSTALL)
EST. CITYCARTAGE
($/ea. or v.m.)
WEIGHT(kg/ea.)
www.inlandpipe.com |
1829mm x 914mm (6'x3')2.5m BOX LENGTH2.0m BOX LENGTH1.8m BOX LENGTH1.5m BOX LENGTH1.2m BOX LENGTH0.6m BOX LENGTHBASE / SLAB TOP 2.5m BEND2.5m BEVELED END1829mm x 1219mm (6'x4')2.5m BOX LENGTH2.0m BOX LENGTH1.8m BOX LENGTH1.5m BOX LENGTH1.2m BOX LENGTH0.6m BOX LENGTHBASE / SLAB TOP 2.5m BEND2.5m BEVELED END2439mm x 1219mm (8' x 4')2.5m Box Length2.0m Box Length1.8m Box Length1.5m Box Length1.2m Box Length0.6m Box Length BASE / SLAB TOP BENDBEVEL END2439mm x 1524mm (8'x5')2.5m BOX LENGTH2.0m BOX LENGTH1.8m BOX LENGTH1.5m BOX LENGTH1.2m BOX LENGTH0.6m BOX LENGTHBASE / SLAB TOP 2.5m BEND2.5m BEVELED END
699455955036419633571679
---
1059484757628635650852543
---
146661173310559879970403520
---
1826914615131531096187694385
---
1025382027382615249212461
3012 / 3586102535126
1171593728435702956232812
4203 / 4859117155858
13368106949625802164163208
5636 / 6214133686684
1910015240137161143091444572
7262 / 8085191009550
---------
---------
---------
---------
---------
---------
---------
---------
---------
---------
---------
---------
---------
---------
---------
---------
Box Sections
Working together to build our communities®
INLAND PIPE | Tel: 780 448 1351 232016 Catalogue
DESCRIPTION OF ITEMS(SPAN x RISE x LENGTH)
VOLUME(L/box)
PRICES per ITEM
• Additional box sizes available; call for details• Prices shown are intended only as an estimating guide; detailed quotations are available upon request• Pricing assumes reinforcement design to CHBDC CSA-S6-06 with CL-800 loading. For other loading conditions, call for estimate.• Add 10% to standard slab top price for a slab top adaptor• Box material is NOT stock material; call for availability• Vertical box application to maximum depth of 10m• Rough cut, cored holes and rake out sections extra; call for pricing• Bend and beveled end sections produced with 2.5m box length (all sizes except 3600 x 3600, which uses a 1.8m box length)
ASTM C1433COVER RANGE1.0m - 3.5m
(HORIZONTAL INSTALL)
ASTM C1443COVER RANGE3.5m - 7.0m
(HORIZONTAL INSTALL)
ASTM C1443COVER RANGE
7.0m - 9.0m (HORZ. INST.)0.0m - 1.0m(VERT. OR HORZ. INSTALL)
EST. CITYCARTAGE
($/ea. or v.m.)
WEIGHT(kg/ea.)
• Box sections manufactured to ASTM C1433 Standard, using sulfate-resistant cement.
2.5m Box Length2.0m Box Length1.8m Box Length1.5m Box Length1.2m Box Length0.6m Box LengthBASE / SLAB TOPBENDBEVEL END
2.5m Box Length2.0m Box Length1.8m Box Length1.5m Box Length1.2m Box Length0.6m Box LengthBASE / SLAB TOPBENDBEVEL END
2.5m Box Length2.0m Box Length1.8m Box Length1.5m Box Length1.2m Box Length0.6m Box LengthBASE / SLAB TOPBENDBEVEL END
1.8m Box Length1.2m Box LengthBASE / SLAB TOPBENDBEVEL END
2.5m Box Length2.0m Box Length1.8m Box Length1.5m Box Length1.2m Box Length0.6m Box LengthBASE / SLAB TOPBENDBEVEL END
2439mm x 1829mm (8' x 6')
2439mm x 2439mm (8' x 8')
3658mm x 3658mm (12' x 12')
3049mm x 2439mm (10' x 8')
3049mm x 1524mm (10' x 5')
www.inlandpipe.com|
10,5948,4757,6286,3565,0852,543
14,66611,73310,5598,7997,0403,520
11,2949,0358,1326,7765,4212,711
18,26914,61513,15310,9618,7694,385
23,75015,830
-
11,7159,3728,4357,0295,6232,812
4203 / 485911,7155,858
13,36810,6949,6258,0216,4163,208
5636 / 621413,3686,684
17,27513,82012,43810,3658,2924,1464,35017,7258,638
19,10015,24013,71611,4309,1444,572
7262 / 808519,1009,550
21,68614,458
12615/1405521,68710,843
---------
---------
---------
---------
-----
---------
---------
---------
---------
-----
---------
---------
---------
---------
-----
---------
---------
---------
---------
-----
Box
Sect
ions
Working together to build our communities®
24 2016 Catalogue INLAND PIPE | Tel: 780 448 1351www.inlandpipe.com |
BENDS (5 • to 50 •)
ADVANTAGES• Cost Effective
• Reduced Vertical Dimension
• Reduced Installation Time
• Low Cover Requirements
• Reduced DewateringRequirements
• Manufactured to InternationalSpecifications
SIDE VIEW FRONT VIEW
VERTICALAPPLICATIONS
(VAULTS)
BEVELED END SECTIONS
• •
APPLICATIONS• Ditch and Creek Replacements
• Storm Sewers
• Highway Culverts
• Pedestrian Underpasses
• Lift Stations
• Utility Vaults
2400mm x 1500mm 203 203 203 254 2542439mm x 1524mm 108
3600mm x 3600mm 305 305 305 400 4003658mm x 3658mm 127
3000mm x 1500mm 254 254 254 254 2543049mm x 1524mm 108
1800mm x 900mm 178 178 178 203 2031829mm x 914mm 102
1800mm x 1200mm 178 178 178 203 2031829mm x 1219mm 102
BITUMINOUS JOINT SEALANT & LUBRICANT0.5" (12.7mm) WIDE KENT SEAL / RUB-R-NEK (12 COILS/BOX)0.75" (19.1mm) WIDE KENT SEAL / RUB-R-NEK (8 COILS/BOX)1.0" (25.4mm) WIDE KENT SEAL / RUB-R-NEK (6 COILS/BOX)1.5" (38.1mm) WIDE KENT SEAL / RUB-R-NEK (4 COILS/BOX)1.0" (25.4mm) WIDE CON-SEAL CS440 OIL GAS RESISTANT (14.5’ COILS)1.5" (38.1mm) WIDE CON-SEAL CS440 OIL GAS RESISTANT (10.0’ COILS)WL-8 GASKET LUBRICANTNC TEE GASKETS - MANHOLE TO PIPE ONLY *PIPE TO PIPE AVAILABLE4.0" (100mm) DIAMETER GASKET for 5.25" (133mm) HOLE SIZE *6.0" (150mm) DIAMETER GASKET for 7.38" (188mm) HOLE SIZE *8.0" (200mm) DIAMETER GASKET for 10" (250mm) HOLE SIZE *10.0" (250mm) DIAMETER GASKET for 12" (300mm) HOLE SIZE 12.0" (300mm) DIAMETER GASKET for 14" (355mm) HOLE SIZE *15.0" (375mm) DIAMETER GASKET for 18" (450mm) HOLE SIZE MANHOLE STEPS (LADDER RUNGS)GALVANIZED; SIZE: 12” x 12” (300mm x 300mm)ALUMINUM; SIZE: 12” x 9” (300mm x 225mm)POLY-COVERED ALUMINUM; SIZE: 12” x 9” (300mm x 225mm)CEMENT & GROUTTYPE HS CEMENT - HIGH SULFATE RESISTANT (40/PALLET)FAST PATCH - 20 MINUTE SET (56/PALLET)SPEED PLUG GROUT*SAFETY PLATFORMS (ALUMINUM)1200mm MANHOLE SAFETY PLATFORM (MSU MODEL #200)1500mm MANHOLE SAFETY PLATFORM (MSU MODEL #200)1800mm MANHOLE SAFETY PLATFORM (MSU MODEL #200)2100mm MANHOLE SAFETY PLATFORM (MSU MODEL #200)2400mm MANHOLE SAFETY PLATFORM (MSU MODEL #200)3000mm MANHOLE SAFETY PLATFORM (MSU MODEL #200)*FRAMES, COVERS & TRASH RACKSF39 FRAMEF39 COVER (GRATED or VENTED)NF 90 FRAME & COVER w/ GASKETF51 FRAMEF51 GRATEF51 SIDE INLETF39 TRASH RACK - STANDARD 500mm HEIGHTF39 TRASH RACK - LARGE 785mm HEIGHT600mm FROST COVER c/w HANDLES900mm FROST COVER c/w HANDLES1200mm FROST COVER c/w HANDLESSWIFT LIFT LIFTING DEVICES4 TON SWIFT LIFT EYE (CLUTCH)8 TON SWIFT LIFT EYE (CLUTCH)4 TON REPLACEMENT PIN w/ WING NUT8 TON REPLACEMENT PIN w/ WING NUT
21.75’ COILS18.0’ COILS14.5’ COILS10.5’ COILS8 COILS/BOX5 COILS/BOX3.6 kg PAIL
1 PIECE1 PIECE1 PIECE1 PIECE1 PIECE1 PIECE
eacheacheach
40 kg BAGS25 kg BAGS25 kg PAIL
18 kg25 kg32 kg37 kg41 kg50 kg
80 kg40 kg127 kg86 kg57 kg78 kg91 kg80 kg3.0 kg4.0 kg6.0 kg
eacheacheacheach
DESCRIPTION OF ITEMSWEIGHT
orQUANTITY
PRICE($/ea.)
EST. CITYCARTAGE
($/ea.)
* Other sizes or types available upon request
CORED HOLEDIAMETER (inch)
PRICE per25mm DEPTH ($) 3000 Barrel 2700 Barrel 2400 Barrel 2100 Barrel 1800 Barrel 1500 Barrel 1200 Barrel
PRICE PER (1) CORED HOLE ONLY
• Minimum Charge for Rough Cut Holes is $204.75 ea.
PRICING UPON REQUEST
CORED HOLE PRICING
Working together to build our communities®
• Do not remove cut-outs until barrels are in final position in the field. • Swift lift clutches are not returnable for refund.
INLAND PIPE | Tel: 780 448 1351 252016 Cataloguewww.inlandpipe.com|
-------
------
---
---
------
-----------
----
-------
------
---
---
------
-----------
----
5" to 8"10" to 14"16" to 22"
22"24"32"36"
Larger than 36"
66.9591.55105.05110.25135.20169.55218.40
-------
-------
-------
-------
-------
-------
-------
FREIGHT GUIDELINES • Estimated city cartage rates shown in this publication are intended as an estimating tool only and are based on truck load
lots larger than 27,000 kilograms. City deliveries include St. Albert, Sherwood Park, Leduc, Spruce Grove & Stony Plain.• Delivery charges for loads will be determined in accordance with the table below:
TERMS AND CONDITIONS OF SALE • Prices listed in this publication are effective as of January 31, 2016
TRI-AXLE
HYBOY
PICKER
TRAILER TYPE LOAD RANGE(kg) M.H. MATERIAL
22000 - 27500
18000 - 22000
10000
-
-
PER HOUR
-
-
PER HOUR
PIPECOST per LOAD ($)
• Prices shown include 60 minutes of unloading time. Trucks held longer than 60 minutes will be subject to additional charges.• $250.00 additional charge for every oversized load (2100mm material and above)• Loads over 12' wide may be subject to additional charges (pilot trucks, extra time)
1. PAYMENT TERMS: Invoices are due and payable on the 25th day of the monthfollowing delivery of Products. Invoices which are not paid by such date are subjectto a service charge of 2% per month (24% per year). If Buyer defaults or if Sellerconsiders Buyer’s financial responsibility impaired or unsatisfactory, Seller shall beentitled to suspend or terminate, in whole or in part, any order or agreement until alloutstanding payments are made and/or acceptable assurances or security is provid-ed by Buyer. In addition to all other rights and remedies available to Seller, Sellershall have the right to recover from Buyer all costs of collection and/or suit, includ-ing reasonable legal fees. Seller’s failure to exercise such rights and remedies orvariance from these terms and conditions shall not constitute a waiver or changehereof unless agreed to by Seller in writing. All material approved for fabricationmust be taken no later then January 31 of the following year. Materials NOT takenprior to the due date will be subject to per diem storage charges.
2. INABILITY TO PERFORM: Seller shall not be liable to Buyer if permanentlyor temporarily rendered incapable of performing its obligations hereunder becauseof strikes, lockouts, differences with workmen, accidents, insurrection, wars, delay orfailure in transportation (including road bans) or by any supplier, shortage of inven-tory, raw materials, facility, equipment, fuel or other material, acts of government,fire, acts of God, acts of any Government or any contingencies beyond Seller’s con-trol. For greater certainty, Seller shall not be required to cross picket lines estab-lished as result of a strike. During any period Seller is rendered incapable of fullyperforming because of any such contingency, Seller shall have the right to prorateamong its various customers such Products as it may be able to manufacture andship.
3. SPECIFICATIONS AND WARRANTIES: PRODUCTS SHIPPED HEREUNDERSHALL CONFORM TO THE PRESENT STANDARD SPECIFICATIONS (FOR THERESPECTIVE PRODUCTS) OF CSA and/or ASTM, AND NO OTHER WARRANTY,REPRESENTATION OR CONDITION OF ANY KIND, EXPRESS OR IMPLIED(INCLUDING NO WARRANTY OF MERCHANTABILITY OR OF FITNESS FORA PARTICULAR PURPOSE) SHALL APPLY THERETO. SELLER HAVING NOCONTROL OVER THE USE OF THE PRODUCTS WILL NOT GUARANTEEFINISHED WORK, NOR SHALL SELLER BE RESPONSIBLE FOR THE CON-DITION OF PRODUCTS AFTER DELIVERY TO BUYER. ANY CHARGESINCIDENTAL TO INSPECTION OR TESTS MADE BY OR ON BEHALF OFBUYER SHALL BE PAID BY BUYER. UNDER NO CIRCUMSTANCES SHALLSELLER BE LIABLE FOR ANY SPECIAL, INCIDENTAL, EXEMPLARY ORCONSEQUENTIAL DAMAGES.
4. TITLE, RISK OF LOSS, CHARGES: Title and risk of loss shall pass to Buyeron customer pick-up at Seller’s premises. Title and risk of loss to Products deliv-ered shall pass to Buyer upon receipt at the destination specified.
5. CLAIMS: Claims for loss or damage in transit must be reported to Seller with-in 24 hours of delivery of Product to the destination specified and must be support-ed by customer’s notation on truck delivery receipt and/or bill of lading.
6. TAXES: Prices are exclusive of all present and future taxes imposed by any fed-eral, provincial, municipal, foreign or local authority.
7. UNLOADING: Buyer will be responsible for unloading Products at the destina-tion specified. If Buyer has not unloaded the truck within one hour of the truck’sarrival at the destination specified, Buyer shall pay an additional charge of $100.00per hour until the truck has been unloaded. All shipments shall be unloaded in theirentirety at the destination specified or will be subject to an additional charge of$100.00 per hour.
8. DELIVERY CONDITIONS: Delivered prices are for delivery to the destinationspecified. The unloading point must be readily accessible and Buyer shall beresponsible to provide suitable access roads to destination specified as well asequipment to unload the Products. In the event Seller requires access over curbs,sidewalks, driveways or other property, Seller shall not be responsible for any loss,cost or damage in connection therewith and Buyer shall indemnify and save theSeller harmless from any such loss, cost or damage.
9. QUOTATIONS: Quotations shall be in effect for a period of thirty (30) days fromthe date of the quote.
10. NOTICE: Buyer shall provide a minimum of twenty-four (24) hours notice ofdelivery.
11. BUILDER’S LIEN: For the purposes of the Builder’s Lien Act Products notherein quoted but delivered or supplied to the same project shall be considered partof the same contract until last date of delivery or supply notwithstanding separatepurchase orders.
12. PRODUCT RETURN: Buyer may return any standard Product to Seller’spremises provided the Product is in good condition and Buyer pays a restocking feeof 15% of the price of the Product.
13. FREIGHT RATES: Freight rates are based on a minimum truck load of 27,000kilograms and do not apply during periods of road restrictions. Delivery charges fortruck loads of less than 27,000 kilograms shall be calculated at an hourly rate asdescribed in the Freight Guidelines outlined in the Seller’s catalogue and shallinclude loading, traveling and unloading time.
Working together to build our communities®
INLAND PIPE | Tel: 780 448 135126 www.inlandpipe.com26 2016 Catalogue INLAND PIPE | Tel: 780 448 1351|
Working together to build our communities®
Lift Chain Sling DetailA B C D
1440mm
(57”)
400mm
(16”)
1040mm
(41”)
1940mm
(76”)
HOISTING GEAR LEG DIMENSIONS
• The measurements listed above are for pipe 1.5m to 2.5m in length.
Notes:1. Swift Lift anchors are available in pipe sizes 1050mm and larger.
2. Pipe 1050mm O/ to 1650mm O/ use the 4 ton lifting eye and pipe 1800mm and larger use the 8 ton lifting eye.
3. Manholes 1200mm and 1800mm use 4 ton lifting eye and manholes 2100mm and larger use the 8 ton lifting eye.
Lifting Eye Clutch for Pipe & Manhole Material
1. To install the P-50 Universal Lifting Eye, hold the unit upside down with the T-shaped slot of the body directly over the head ofthe swift lift anchor.
2. Lower the body of the lifting eye until the T-shaped slot engages the head of the anchor.
3. Rotate the body until the extended lip of the body touches the concrete surface.
Swift Lift
INLAND PIPE | Tel: 780 448 1351 272016 Cataloguewww.inlandpipe.com|
Working together to build our communities®
Correct Method for Homing the Pipe Together
How to Maneuver Pipe Using Swift Lift
1. The pipe is first transported to the installation site with the symmetrical sling and lowered close to the alreadyplaced pipe.
Note: a) As with lifting any concrete element, special care should be taken by the driver of the placement vehicleto ensure the impact or dynamic loads are reduced to a minimum. Because these loads can greatlyincrease the weight of the element, and this safety note should not be overlooked.
b) Load must be applied simultaneously to all Swift Lift Anchors in order to safely lift product.
1. To pull the pipe into position, the long leg of the hoisting gear is coupled to the previously placed pipe.
2. Eye 2 is disconnected from the swift lift anchor and attached to master link.
3. Eye 3 is then connected to the pipe you will be homing to.
4. Crane or backhoe operator must ensure the lifting point is over the outer lifting anchor of the previously placed pipeso that the direction of pull is slightly inclined toward placed pipe.
5. Operator must then lift up on the hoisting gear until pipe is homed together.
Swift
Lift
INLAND PIPE | Tel: 780 448 135128 2016 Catalogue www.inlandpipe.com |
This pipe does not move This pipe does not move Direction of Pipe Travel
D C
5°Eye 2
AB
Eye 3
Eye 1
Inclination 45° to 50°
As CloseAs Possible
Working together to build our communities®
INLAND PIPE | Tel: 780 448 1351 292016 Cataloguewww.inlandpipe.com|
250 - 900 PIPE (DO NOT HAVE LIFTING PINS)
1050 - 1650 PIPE
1800 - 3000 PIPE
FLARED ENDS
300 FE TO 1200 FE BELL / SPIGOTS
1350 FE TO 1500 FE BELL / SPIGOTS
BENDS1200 - 1650 BEND1800 - 2100 x 2.5M BEND
2700 x 2.5M BEND3000 BEND
2400 X 1200 BOX BEND
2400 X 1800 BOX BEND
2400 X 2400 BOX BEND
PLUGS / CAPS / ADAPTORS
1500 SPIG TO SPIG ADAPTOR
1800 X 1650 REDUCER
1200 - 1650 CAP / PLUG
1800 - 3000 CAP / PLUG
1800 X 1200 BOX CAP / PLUG
2400 X 1200 BOX CAP / PLUG
2400 X 1800 BOX CAP / PLUG
2400 X 2400 BOX CAP / PLUG
3000 X 2400 BOX ADAPTOR
1050 - 2100 INCREASE / DECREASER
TEE RISERS
1050 - 1650 T-RISER
1800 - 3000 T-RISER
1200 T RISER SADDLE
1200 MANHOLE MATERIAL
1200 BASE
1200 RISERS
1200 CONE
1200 SLABTOP
1200 PREBENCHES
CATCH BASIN MATERIAL
600 / 750 / 900 CB'S & RISERS
900 BASE
900 SLABTOP /K2 / K3 / DK7 / E-TOP / T-TOP / M-TOP
0
4T
8T
4T
4T
4T8T
8T8T
8T
8T
8T
4T
8T
4T
8T
4T
8T
8T
8T
8T
4T
4T
8T
4T
4T
4T
4T
4T
4T
4T
4T
4T
0
2 LP
2 LP
2 LP
4 LP
4 LP4 LP
4 LP4 LP
4 LP
4 LP
4 LP
2 LP
2 LP
3 LP
3 LP
6 LP
6 LP
6 LP
6 LP
4 LP
2 LP
2 LP
2 LP
2 LP
1 LP
2 LP
2 LP
2 LP
2 LP
2 LP
1 LP
2 LP
PIPE TON LIFT PINS
Working together to build our communities®
1500 - 1800 BASE
2100 BASE
2400 - 2700 BASE
3000 BASE
3600 BASE
1500 - 1800 ST 635 / 710 / 914 / 1200
1500 K3 / ETOP
2100 - 2700 ST 635 / 710 / 914 / 1200
2100 - 2400 SLABTOP W / HATCH
3000 SLABTOP (ALL)
3600 SLABTOP
1500 - 1800 RISERS
2100 - 3000 RISERS
3600 X 1.0M RISER
BOX SECTIONS
1200 X 600 / 900 BOX BEVEL
1200 X 600 - 900 BOX BASE / SLABTOP
1200 X 600 - 900 BOX MATERIAL
1800 X 1200 BOX BASE / SLABTOP
1800 X 1200 BOX MATERIAL / T-RISER
2400 X 1200 BOX MATERIAL / SLABTOP
2400 X 1200 BOX BASE
2400 X 1800 BOX SLAB / BASE / BOX MATERIAL
2400 2400 BOX MATERIAL
2400 X 2400 BOX BASE / SLAB
3000 X 2400 BOX BASE / ST / BOX MATERIAL / BELL / SPIGOT
VAULTS1220 X 1220 X 1000 VAULT RISER
1220 X 1220 X 2000 VAULT
1525 X 1525 X 1000 VAULT RISER
1525 X 1525 X 2000 VAULT
1830 X 1830 X 1000 VAULT RISER
1830 X 1830 X 2140 VAULT
1980 X 1980 X 1000 VAULT RISER
1980 X 1980 X 2200 VAULT
2400 X 2400 X 1000 VAULT RISER
2400 X 2400 X 2380 VAULT
2800 X 2800 X 1000 VAULT RISER
2800 X 2800 X 1400 VAULT RISER
2800 X 2800 X 2800 VAULT
4T
8T
8T
8T
8T
4T
4T
8T
8T
8T
8T
4T
8T
8T
4T
4T
4T
4T
8T
8T
8T
8T
8T
8T
8T
4T
4T
4T
4T
4T
4T
4T
4T
8T
8T
8T
8T
8T
1 LP
1 LP
3 LP
4 LP
4 LP
3 LP
2 LP
3 LP
4 LP
3 LP
4 LP
3 LP
3 LP
3 LP
4 LP
2 LP
4 LP
4 LP
4 LP
4 LP
2 LP
4 LP
4 LP
4 LP
4 LP
4 LP
8 LP
4 LP
8 LP
4 LP
8 LP
4 LP
8 LP
4 LP
8 LP
4 LP
4 LP
8 LP
LARGE DIAMETER MANHOLE MATERIAL TON LIFT PINS
3600 X 3600 BASE 8T 4 LP
3600 X 3600 ST 8T 4 LP3600 X 3600 BOX MATERIAL 8T 4 LP
30 2016 Catalogue www.inlandpipe.com |
2016 Catalogue 31www.inlandpipe.com|
32 2016 Catalogue INLAND PIPE | Tel: 780 448 1351www.inlandpipe.com |
Di
Do/3
Do/6 (Min.)Do Do (Min.)
H
Bedding -See Table
Haunch - See TableLower Side - See Table
Middle bedding looselyplaced uncompactedbedding except Type 4Outer bedding materials
and compaction each side,same requirements as haunch
Overfill - SW, ML, or CL
Foundation
Springline Di
Do/3
Do/6 (Min.)Do Do (Min.)
H
BeddingSee Tables 1 & 2
Haunch - See Table
Lower Side - See Table
Middle bedding looselyplaced uncompactedbedding except Type 4Outer bedding materials
and compaction each side,same requirements as haunch
Overfill Soil -SW, ML, or CL
Foundation
Springline
INLAND PIPESpyhill Facility
Po. Box 306,Hwy #1E.Regina, SK S4P 3A1Tel: 306 209 5618Fax: 306 789 7499