Noise stop tape extend your outdoor lifestyle · E [email protected] Queensland T 07 3717 4700...
Transcript of Noise stop tape extend your outdoor lifestyle · E [email protected] Queensland T 07 3717 4700...
only Laserlite® has the technologyLaserlite® is the only polycarbonate corrugated sheet product in Australia featuring
Advanced Weatherguard™ technology, a special protective material that is warranted to• Extend the life of the sheet by up to 50%#• Maintain sheet colour and clarity up to 50% longer#• Provide 99.9% protection from UV rays up to 50% longer#• Resist 25% larger hailstones#With unrivalled technology and superior performance, it’s clear why Laserlite® is part of the Australian outdoor lifestyle.
Comfort Cool™ keeps you cool and comfortable.
feature Comfort Cool™ Technology, special properties in the
• Up to 50% better heat reduction than standard corrugated sheet#• reduced glare for ultimate comfort
# As compared to some other polycarbonate corrugated sheet products.
How it works How it worksUV rays, wind, hail and rain have the potential to make polycarbonate resins brittle and lose colour over time. Advanced WeatherguardTM protects the sheet and protects from harmful UV radiation.
Infra red light emitted by the sun passes through polycarbonate sheet making it warm underneath. Comfort Cool™letting visible light through with less glare.
Up to 50% better heat reduction
than standard corrugated
sheet#
* colour selection. Slight colour variation may occur between production runs. Transmitted light and colour may vary in intensity depending on weather conditions. The information contained in this brochure is to the best of our knowledge accurate, but all recommendations are made without any warranty whatsoever, since the conditions of use are beyond our control. This brochure cancels and supersedes all previous publicised information. The company reserves the right to alter and revise, without notice, the information contained herein.
www.laserlite.com.au
extend your outdoor lifestyle
Save 50% installation
time
1
3
4
2Easy to install, Laserlite® has a quality range of accessories to ensure a
When installed against a wall
Laserlite® One Shot® Time Saving Fixing System saves 50% installation time as no pre-drilling is required. They also feature a Class 4 coating for superior corrosion resistance and suitability for coastal areas.
New South Wales T 02 9677 9900 F 02 9677 9500 E [email protected]
Victoria T 03 8791 8000 F 03 8791 8088 E [email protected]
Queensland T 07 3717 4700 F 07 3717 4777 E [email protected]
South Australia T 08 8444 9666 F 08 8444 9600 E [email protected]
Western Australia T 08 9240 6655 F 08 9240 8877 E [email protected]
Tasmania T 03 6288 6000 F 03 6288 6010 E [email protected]
Prevents rain,dust and wind entering the eaves
Barge cappingPrevents wind & rain entering the gable ends
Metal ridge cappingPrevents roof leaking at apex
Prevents leaking at walls and facias
Prevents leaking at walls and facias
1 2
3 4
Noise stop tape Reduces creaking
the solution for a
• Lifetime Platinum Warranty* • Lifetime Platinum Warranty*
greca corrugated greca corrugated
platinum ice gun metal
clear opal cream bronze tint
grey tint
Laserlite® 2000 Lengths available - 1.8m, 2.4m, 3.0m, 3.6m, 4.2m 4.8m, 5.4m, 6.0m, 7.2m, 9.0m
Sheet width Corrugated 840mm Greca 810mm 5 - rib 830mm
Cover width Corrugated 755mm Greca 760mm 5 - rib 762mm
‡ # As compared to some other polycarbonate corrugated sheet products.
The classic, high performing Laserlite® range.
Performance & reliability Ultimate comfort
Laserlite® 3000Lengths available - 1.8m, 2.4m, 3.0m, 3.6m, 4.2m, 4.8m, 5.4m, 6.0m, 7.2m, 9.0m
Sheet width Corrugated 840mm Greca 810mm
Cover width Corrugated 755mm Greca 760mm
PRODUCT TECHNOLOGIES PRODUCT TECHNOLOGIES
1. SELECT PRODUCT 1. SELECT PRODUCT
2. SELECT COLOUR 2. SELECT COLOUR
3. SELECT PROFILE 3. SELECT PROFILE
4. SELECT LENGTH 4. SELECT LENGTH
Up to 50% better heat reduction
performancethan standard
corrugated sheet!#
for the ultimate outdoor lifestyle experience.
With Comfort CoolTM Technology
Light 93% 49% 43% 38% 19%Transmission % Heat 0% 52% 62% 33% 47%Reduction % ‡
Light 18% 47% 16%Transmission % Heat 69% 63% 66%Reduction %‡
5 - rib
clear opal cream bronze tint grey tint platinum ice gun metal
clear opal creambronze tint
grey tint
platinum ice gun metal
MORE LIGHT LESS LIGHT
COOLERWARMER
Light level
Comfort level
Light level
Comfort level
MORE LIGHT LESS LIGHT
COOLERWARMER
‡
Eave In�ll StripsPrevent rain, dust and wind entering eaves
Noise Stop TapeReduce creaking
Safety Recommendations- Always exercise extreme care when walking on a roof.- Never walk on or apply your load directly to sheeting. - In particular consider all safety requirements when working at heights above 2m.- For safety reasons we recommend the use of safety mesh for installations above 3m.- Use appropriate personal protective equipment (PPE) such as safety footwear, glasses and gloves.- All safety practices must comply with the applicable local building and/or work cover code(s).- We do not recommend the collection of drinking water from any roof without Check with your local water authority for further advice.
CAUTION: To maximise the life cycle of your Laserlite® ® recommends avoiding exposure of polycarbonate sheeting to excess heat from patio heaters. Maintain a distance of 1 metre minimum between the sheets and the heater with adequate ventilation at all times and temperature to below 90°C beneath the sheeting. If the temperature rises above 90°C, remove the heater immediately.
Carefully read all installation instructions before you start.• For installation in cyclonic regions, contact your nearest Laserlite o�ce for special instructions.
Safety Recommendations
Installation InstructionsPurlin end span spacing
(refer Table X)
Purlin mid span spacing (refer Table X)
Barge Capping
Laserlite screwsand weatherseals(refer Table Y for spacing)
Apron FlashingPurlins
Rafters
Fascia
Foam In�ll
Laserlite Polycarbonate RoofPurlin
Back Channel Flashing
Gutter
Purlin end span spacing (refer Table X)
Purlin mid span spacing (refer Table X)
Barge Capping
Laserlite screwsand weatherseals(refer Table Y for spacing)
Apron FlashingPurlins
Rafters
Fascia
Foam In�ll
Laserlite Polycarbonate RoofPurlin
Back Channel Flashing
Gutter
Table X – Maximum Purlin Spacings
Pro�le End Span Mid Span
Roma 800mm 1000mm
Greca 900mm 1200mm
Trimdek 900mm 1200mm
Table Y – Fixing Spacings
Pro�le End Purlins Mid Purlins
Roma Every 2nd crest Every 3rd crest
Greca Every 2nd crest Every 3rd crest
Trimdek Every crest Every crest
18mm
thickness = 0.8m m
thickness = 0.8m m
thickness = 0.8m m
760mm
76mm
18mm
840mm
760mm
76mm
815mm
25mm
25mm
25mm
60mm
20mm
13mm
29mm
762mm
191mm830mm
170˚
25mm
cover width
sheet width
cover width
sheet width
cover width
sheet width
Greca
Trimdek
Product PerformanceShading Co-e�cient Ratio (SC)
Light T ransmission (L T)
Clea
r 1.
01
Bron
ze T
int
0.68
Grey
Tin
t 0.
55
Opa
l 0.
53
Oce
an B
lue
0.
50
Gum
leaf
0.
43
Arct
ic Ic
e
0.39
Ston
e 0.
36
Gun
Met
al
0.35
Ivor
y 0.
35
Satin
Sag
e 0.
34
Met
allic
Bro
nze
0.34
Satin
Cre
am
0.33
Stee
l 0.
32
Oliv
e M
ica
0.
31
Plat
inum
0.
31
Clas
sic C
ream
0.
30
Clea
r 93
%
Opa
l 56
%
Satin
Cre
am
51%
Arct
ic Ic
e
44%
Bron
ze T
int
35%
Ivor
y 35
%
Clas
sic C
ream
33
%
Ston
e 29
%
Satin
Sag
e 28
%
Grey
Tin
t 19
%
Gum
leaf
19
%
Oce
an B
lue
18
%
Plat
inum
17
%
Oliv
e M
ica
15
%
Met
allic
Bro
nze
15%
Stee
l 15
%
Gun
Met
al
13%
XPT 2000 Apollo
More Light Less Light
Warmest Coolest
Weight Roma Greca Trimdek
Kg per Lineal Metre 0.92 0.93 0.92
Kg per m2 1.10 1.13 1.11
Available Sizes Standard lengths in metres: 1.8, 2.4, 3.0, 3.6, 4.2, 4.8, 5.4, 6.0, 7.2 Lengths up to 10 metres can be ordered (conditions apply)
Roma
Shading Co-e�cient (SC): A ratio of the warming e�ect of the sun’s rays through a sheet divided by the sun’s warming e�ect through 3mm �oat glass (300-2500nm). The lower the �gure the cooler it is under the sheet.
Table Z – Side Laps
Roma – 1 1/2 corrugations
Greca – 1 corrugation
Trimdek – 1 corrugation
Prevailing Wind Direction
Product RangePro�les
Light Transmission (LT): % of visible light transmission (400-700nm) that passes through the sheet. The lower the �gure the less light passes through the sheet.
Ensure that your roof pitch is at least 5 º, i.e. 88mm rise per lineal metre. This will ensure adequate water run o�.
Allow for ventilation, particularly at the highest point, to minimise heat build-up and provide air circulation. Good ventilation will also minimise condensation in cold weather. For roo�ng, purlin/batten spacings should be no more than those shown in Table X – Maximum Purlin Spacings. For curved structures, the maximum purlin spacing should be 750mm and a minimum radius of 6000mm for Roma and Greca pro�le and 14000mm for Trimdek pro�le. For walls, nogging spacings should be no more than 1200mm. Use Laserlite Noise Stop Tape on all battens, purlins or noggings to minimise the noises associated with expansion and contraction. Ensure the UV surface protected side faces the sun. This is the side of the label and the inkjet marking. When installed as a wall or fence it is recommended that the UV protected side is facing the most sun. The life of the sheet may be shortened and discolouration may occur due to the unprotected side being exposed to UV radiation. The sheet can be easily cut with a pair of shears, a �ne-toothed handsaw or a circular saw with a cut-o� blade suitable for plastic. In normal conditions, use the �xing spacings shown in Table Y – Fixing Spacings. As a guide, you will need approximately 7 �xings per lineal metre. This depends on your purlin spacings and wind conditions. In high wind areas �x Roma and Greca on every second corrugation on each purlin/batten. It is suggested that barge capping be used. Fix the sheet through the crests for roo�ng with Laserlite One-Shot Fixings and through the valleys for walls with Laserlite Fixings for Cladding or Laserlite Standard Fixings. For roof laying, start with the lower sheets �rst, keeping side laps away from prevailing wind. Allow an overhang of 50mm. Temperature changes will cause expansion and contraction, so make allowances for thermal movement. Resistance to movement can cause buckling. To ensure maximum performance of the sheet, and to avoid buckling, it is necessary to oversize the holes and centre the �xings. It is recommended that Laserlite One-Shot Fixings are used. They come complete with their own hole saw that cuts an expansion hole as you drill. The screw is centred every time and the cutter holds the plug of material removed. If using Laserlite Fixings for Cladding or Laserlite Standard Fixings, pre-drill your �xing holes. Use a 10mm drill for sheets up to 4.2m long and a 12mm drill for sheets longer than 4.2m. Fix the sheet through the centre of the pre-drilled holes, perpendicular to the purlins/battens. A (5/16”) Drill hex driver bit should be used. Only tighten the �xings enough to prevent rattling. Over-tightening may cause distortion and undue stress with possible failure resulting. Use only Laserlite branded �xings as these are designed to be compatible with Laserlite Polycarbonate Roo�ng. Any failure of the sheet due to �xings other than Laserlite branded will void the Laserlite warranty. Side laps will di�er by pro�le. Install as shown in Table Z. End overlaps should be 150mm for steep pitch or 200mm for shallow pitch.
1
2
3
4
5
6
7
8
9
10
1 metre
88m
m
5˚
264m
m
5˚
3 metres
1 metre
88m
m
5˚
264m
m
5˚
3 metres
CAUTION – To maximise the life of your Laserlite roo�ng, Laserlite recommends to avoid exposing your polycarbonate sheeting to excess heat from patio heaters. Laserlite recommends a distance of 1m is kept between the sheets and the heater, adequate ventilation at all times and temperature to be below 90 ºC beneath the sheeting. If temperature underneath your sheet rises above 90 ºC, immediately remove the patio heater from underneath the polycarbonate sheeting.
• Always exercise extreme care when walking on any roof. • Never walk on or apply a load or your weight directly to sheeting. • In particular consider all safety requirements when working at heights
above 2m. • For Safety precautions we recommend the use of safety mesh for
installations above 3m. • Use appropriate personal protective equipment (PPE) such as safety
footwear, safety glasses and gloves. • All safety practices must comply with the applicable local building
and/or work cover code(s).
• Refer to Safety Recommendations. • Installations must comply with the applicable building code. • We do not recommend the collection of drinking water from any roof
without appropriate precautions and �ltration. Check with your local water authority for further advice.
StepPurlins & accessories
Step
1. Ensure that your roof pitch is at least 5°, ie. 88mm rise per lineal metre.This will ensure adequate water run off.
2. Allow for ventilation, particularly at the highest point, to minimise heat build-up and provide air circulation. Good ventilation will also minimise condensation in cold weather.
be no more than those shown in Table X - Maximum Purlin Spacings. For curved structures, the maximum purlin spacing should be 750mm and a minimum radius of
spacings shoud be no more that 1200mm. Use Laserlite® Noise Stop Tape on all battens, purlins or noggings to minimise the noises associated with expansion and contraction.
4. Lay Laserlite® Noise Stop Tape to avoid creaking.
5. Lay Laserlite® at eaves to avoid rain,dust & wind entering the eaves.
metal back channel with prior to laying sheet.
1. Ensure that the UV surface protected side faces the sun. This is the side of the label and the inkjet marking. When installed as a wall or fence it is recommended that the UV protected side is facing the most sun. The life of the sheet may be shortened and discolouration may occur due to the unprotected side being exposed to UV radiation.
Prevailing Wind Direction
5. To ensure maximum performance of the sheet, and to avoid buckling, it is necessary to
recommended that Laserlite® One Shot®are used. They come complete with their own hole saw that cuts an expansion hole as you drill. The screw is centred every time and the cutter holds the plug of material removed. If using Laserlite®
holes. Use a 10mm drill for sheets up to 4.2m long and a 12mm drill for sheets longer than 4.2m. Fix the sheet through the cerntre of the pre-drilled holes, perpendicular to the purlins/battens. A (5/16”) Drill hex driver bit should be
rattling. Over tightening may cause distortion and undue stress with possible failure resulting. Use only Laserlite® are designed to be compatible with Laserlite®
® branded will void the Laserlite® warranty.
shown in Table Z - Fixing spacings. As a guide, you will need approximately 7
purlin spacings and wind conditions. In high
second corrugation on each purlin/batten. It is suggested that barge capping be used. Fix the sheet through the valleys for walls with Laserlite® Standard Fixings.
Using One Shot® eliminates requirement for pre-drilling.
6. End overlaps should be 150mm for steep pitch or 200mm for shallow pitch.
APEX ROOF - Fit metal barge capping to the edge of sheet and metal ridge capping to the apex.
UNDER A GUTTER - Fit back channel
prior to laying sheets and metal barge capping to edge of sheet.
AGAINST A WALL/FASCIA - Fit metal barge capping to edge of sheet and metal apron
Step
Table X - Maximum Purlin Spacings Span Mid Span
Corrugated 800mm 1000mmGreca 900mm 1200mm5 Rib 900mm 1200mm
Table Z - Fixing Spacing Purlin Mid Purlins
Corrugated every 2nd crest every 3rd crestGreca every 2nd crest every 3rd crest5 Rib every crest every crest
Corrugated - 1 1/2 corrugations
Greca - 1 1/2 corrugations
5 Rib - 1 corrugations
2. The sheet can be easily cut with a pair of
saw with a cut-off blade suitable for plastic.
3. For roof laying, start with the lower
prevailing wind. Allow an overhang of 50mm. Temperature changes will cause expansion and contraction, so make allowances for thermal movement. Resistance to movement can cause buckling.
shown below:
Table Y - Side laps
for various installations
Installation Guide1
2
3