nikhil ppt.pdf

download nikhil ppt.pdf

of 45

Transcript of nikhil ppt.pdf

  • 8/10/2019 nikhil ppt.pdf

    1/45

  • 8/10/2019 nikhil ppt.pdf

    2/45

  • 8/10/2019 nikhil ppt.pdf

    3/45

    350 BEDDED GENERAL HOSPITAL AT SUSHANT GOLF CITY, LUCKNOW

    Submitted By:Prachi Gupta

    Roll No. - 817

    IIA Part-IV-Group-B (2014-15)

    ACKNOWLEDGEMENT

    I would like to express my sincere gratitude to my thesis guide Ar. K.K. Asthana, for his concern, support and

    guidance throughout my thesis. He sorted out all my problems and queries and gave valuable suggestions tobenefits my project.

    I am grateful to our thesis coordinator Ar. Manoj Kumar for his unending and unritiring support

    provided to me at all stages of my thesis. His invaluable knowledge was shared for my thesis.

    Secondly I would like to thanks all those people who have been associated with this assignment and

    have helped me in this project and made it a worthwhile experience.

    Finally, I would also like to thank my parents and friends who helped me a lot in finishing this projectwithin the limited time. And also a big thanks to the various people who have shared their opinions and experiences

    through which I received the required information beneficiary for my project.

    Thank you!

    PRACHI GUPTA

  • 8/10/2019 nikhil ppt.pdf

    4/45

    350 BEDDED GENERAL HOSPITAL AT SUSHANT GOLF CITY, LUCKNOW

    Submitted By:Prachi Gupta

    Roll No. - 817

    IIA Part-IV-Group-B (2014-15)

    INTRODUCTION

    The hospital is an integral part of a social & medical organization, the

    function of which is to provide for the population complete health care, both

    curative and preventive, and whose outpatient services reach out to the

    family and its home environment, the hospital is a center for the training of

    health workers and biosocial research.

    WHO definition of Hospital

    Hospital is a premise medical facilities of general or specialized nature for

    treatment of indoor and outdoor patients. A hospital is a place which delivers

    health services to the people and where the patients are cared for nurse and

    treated. It is an integral part of social and medical organization, the function

    of which is to provide for the population complete health care, both curative

    and preventive. The modern concept goes beyond the conventional idea of ahospital as place for treatment of the sick. It visualize as hospital is one of

    comprehensive system of preventive and curative medicine and as an

    institution devoted not only to patients treatment but also to a ambulatory and

    domiciliary care.

    A hospital building is something difficult that is difficult to change when it has

    been constructed. The methods of looking after the patients, nursing and

    treatment however continually and rapidly due to the development of medical

    science hence its challenge job for an architect to design such a building.

    IndiasPublic Health System has been developed over the years as a 3-tier

    system, namely primary, secondary and tertiary level of health care. Health

    System is the fundamental basis for implementing various health policies,

    delivery of healthcare and management of health services for defined

    geographic area. Hospital is an essential component of the health system

    and functions as a secondary level of health care which provides curative,

    preventive and promotive healthcare services to the people.

    TYPES OF HOSPITALS

    1. TEACHING / RESEARCH HOSPITALS

    2. GENERAL HOSPITALS3. TERTIARY CARE SPECIALTY HOSPITALS

    FEATURES

    1. Orientation

    2. Planning of traffic & Circulation (Patients, Staffs, visitors, Service

    deliveries, Garbage & Waste removal)

    3. Easy traffic movement & promote efficiency of operation.

  • 8/10/2019 nikhil ppt.pdf

    5/45

  • 8/10/2019 nikhil ppt.pdf

    6/45

    350 BEDDED GENERAL HOSPITAL AT SUSHANT GOLF CITY, LUCKNOW

    Submitted By:Prachi Gupta

    Roll No. - 817

    IIA Part-IV-Group-B (2014-15)

    SITE LOCATION

    Showing Lucknow in India

    Location of Sushant Golf city on Lucknow City Map

    Layout of Sushant Golf CityProposed site of Hospital

    HOSPITAL BLOCK

  • 8/10/2019 nikhil ppt.pdf

    7/45

    350 BEDDED GENERAL HOSPITAL AT SUSHANT GOLF CITY, LUCKNOW

    Submitted By:Prachi Gupta

    Roll No. - 817

    IIA Part-IV-Group-B (2014-15)

    30.0MT.WIDEROAD

    9.0 MT. WIDE ROAD

    COMMERCIAL

    350 BEDDED

    HOSPITAL BLOCK

    63.14 m

    244.82m

    206.81m

    225.41 m

    SITE AREA

    Hazaratganj 5 Kms.

    Amausi Airport 13 Kms.

    SGPGI 13 Kms.

    Charbagh Railway Station 9 Kms.

    Vidhan Sabha 6 Kms.

    DISTANCES FROM IMPORTANT LANDMARKS

    Total area of site

    50909.37

    Sq. mt.

    12.58 Acres

    5.09

    Hectares

    Permissible ground Coverage

    30 %

    15272.81

    Sq. mt.

    Permissible FAR 2.5

    127,273

    Sq. mt.

    BYE LAWS

    Site is allotted for health care facilities by Ansal Infrastructure pvt. Ltd.

    SOCIO ECONOMIC ISSUES

    The site is of private builder, Ansal

    infrastructure pvt. Ltd. The hospital will

    serve as general hospital facilities to

    sushant golf city and near by adjacent

    population.

  • 8/10/2019 nikhil ppt.pdf

    8/45

  • 8/10/2019 nikhil ppt.pdf

    9/45

    350 BEDDED GENERAL HOSPITAL AT SUSHANT GOLF CITY, LUCKNOW

    Submitted By:Prachi Gupta

    Roll No. - 817

    IIA Part-IV-Group-B (2014-15)

    SITE CONSIDERATION

    APPROACH: Site is approached by 45.0 mt. wide

    service road from front side adjacent to Amar

    shaheed path road. Amar Shaheed Path is an

    elevated road, and connects traffic from Kanpur to

    Rae Bareli, Sultanpur and Faizabad, or vice versa.

    The road starts at Faizabad Road passes through

    Sultanpur Road (near Gomti nagar extension), Rae

    Bareli Road and ends at Kanpur road, spanning astretch of approximately 23 km.

    45 mt. wd service road

    9.0mt. wd road

    24.0mt. wd road30.0mt.Wdroad

    Commercialland

    Amar shaheed path road

    N

    S

    W

    E

    TOPOGRAPHY: Site has little undulation with somemounds, can be considered as flat land.The site is Approx. 6 mt. below the highway.

    EXISTING VEGETATION: There is no significantvegetation except some buses and shrubs.

    SOIL CONDITION: The soil character istics foundhere are deep, moderately well drained to well

    drained with loamy surface texture,

    SURROUNDING: Green park in north west side. Muzhaffar nagar ghuswal village at south east side.

    Commercial land on north east side.

    30 mt wide road in west direction.

    Existing site view

    WATER SUPPLY:

    DRAINAGE:

    The rainfall water will be disposed-off in two

    ways, one is through Internal drainage system,

    which will carry rooftop water to recharge pit

    and second External Drainage system, in

    which the overflow from recharge pit will be

    carried by drainage line proposed by ansal cityand ultimately terminating to the existing

    natural pond.

    The potable water supply of desired quality and

    purity shall be ensured by tapping under ground

    water.

    Therefore, the sources of water identified for

    water supply system in the project are:

    1. Ground water as under ground tank.

    2. Recycling of treated effluent form STP for

    gardening.

    POWER SUPPLY:

    11 KV H.T. line is available from Ahemamau,

    substation.

    TELEPHONE:

    Telephone line underlying by the telephone

    department.

  • 8/10/2019 nikhil ppt.pdf

    10/45

    350 BEDDED GENERAL HOSPITAL AT SUSHANT GOLF CITY, LUCKNOW

    Submitted By:Prachi Gupta

    Roll No. - 817

    IIA Part-IV-Group-B (2014-15)

    CLIMATE AND RAINFALL

    Climate of Lucknow can be summarized as warm

    sub tropical climate with cool and dry winters from

    December to February and Hot and Dry summers

    from April to June.

    Rainy season generally continues from mid June to

    mid September, when Lucknow gets an average

    rainfall of 1010 mm (40 inches) mostly from the South

    West monsoon winds.Summers are generally quite hot with temperatures

    rising from 40 to 45 degrees Celsius range, the

    average high temperature being 31 degree Celcius.

    In winters, the maximum temperature is around 21

    degree Celsius and the minimum ranges from 3 to 4

    degree Celsius. Fog is commonly observed from late

    December to late January.

    WIND DIRECTION

    ANNUAL RAINFALL

    Winds

    Hot and dusty during summer

    Dry and cold winds from in winter north east

    Winds in monsoon from south east

    Relative humidity:Dry period 20-55%

    Wet period 55-95%

    CLIMATIC INFERENCES:

    Building should be designed to provide comfort, any

    building surface such as window, walls and roof that is

    exposed to sun can admit solar radiation, to avoid the

    inwards flow of heat. either direct or indirect, The

    surface on which the sun rays fall must be protected,

    besides preventing direct radiation of sun as efficient control

    system should take into consideration the following:

    Maximum of solar heat entering room in winter.

    Protection against and wind and rain

    Provision of adequate ventilation at all times.

    Control of insects ,dirt ,dust.

    Adequate exterior vision.

    ORIENTATION:

    The prevailing flow towards the south

    east direction through major part of the

    year.

    The building should be oriented in such a

    way that a maximum no. of opening should

    get the natural north light so, max. number

    of opening should be north side.

    FORM AND PLANNING:

    Courtyard types buildings are very

    suitable .it is the most pleasant space for

    most of the year.

    Because it allows wind and traps the sun.Deduction of surface exposed to solar

    radiation.

    Shading of external walls through

    provision of louvers, fins and recessedwindow.

  • 8/10/2019 nikhil ppt.pdf

    11/45

    350 BEDDED GENERAL HOSPITAL AT SUSHANT GOLF CITY, LUCKNOW

    Submitted By:Prachi Gupta

    Roll No. - 817

    IIA Part-IV-Group-B (2014-15)

    ORIENTATION ACCORDING

    TO SUN

    ORIENTATION ACCORDING

    TO WIND

    MOST SUITABLE

    ORIENTATION

    SUN MOVEMENT DIAGRAM

  • 8/10/2019 nikhil ppt.pdf

    12/45

    350 BEDDED GENERAL HOSPITAL AT SUSHANT GOLF CITY, LUCKNOW

    Submitted By:Prachi Gupta

    Roll No. - 817

    IIA Part-IV-Group-B (2014-15)

    LITERATURE STUDY & STANDARDS

    OPD

    -Emergency/

    casualty

    -Consultancyservices

    -Diagnostic

    facilities

    -Physiotherapy

    -Pharmacy

    IPD

    -Surgical suites-

    ICU/ CCU/ HDU

    -Cath lab-Day care

    -Pathology

    -Wards

    SERVICES

    -CSSD

    -Laundry & Linen

    -Stores-Diet Kitchen

    -Bio-medical

    HOSPITAL PLANNING HAVE 3 MAIN AREAS:

    ENTRANCE AREA :There can be 4 access points to the site, in order to

    segregate the traffic.

    1.Emergency: for patient in ambulances and other

    vehicles for emergency department.

    2.Service: for delivering supplies and collecting

    waste.

    3.Service: for removal of dead.4.Main : for all others.

    ENTRANCE

    EMERGENCY MAIN FOR ALL

    SERVICE

    DELIVERYSERVICE

    FOR DEAD

    ENTRANCE DIAGRAM

    O.P.D. (OUT PATIENT DEPARTMENT):

    OUT PATIENT ENTRANCERECPTION/ ENQUIRY

    WAITING AREA

    REGISTRATION/

    MEDICAL RECORD

    WAITING AREA

    CONSULTATION/EXAMINATION

    MINOR TREATMENT AND

    PROCEDUREADMITTING OFFICE

    HOSPITAL INPATIENT X-RAY LAB OTHER NVESTIGATION AND

    THERAPEUTIC FACILITIES

    DISPENSING PHARMACY INJECTION DRESSING

    OUT PATIENT

    O.P.D. LAYOUT CHART

    It should also be easily accessible to the laboratories,

    radiology, pharmacy and physical therapy department

    since outpatients use practically all of the diagnostic and

    therapeutic departments during every visit.

  • 8/10/2019 nikhil ppt.pdf

    13/45

    350 BEDDED GENERAL HOSPITAL AT SUSHANT GOLF CITY, LUCKNOW

    Submitted By:Prachi Gupta

    Roll No. - 817

    IIA Part-IV-Group-B (2014-15)

    EMERGENCY SERVICES :

    LOCATION:Should be located on the ground floor.

    Easy access for patient and ambulances.It should preferably have a distinct entry independent

    of OPD main entry so that a very minimum time is lost

    in giving immediate treatment to causalities arriving in

    the hospital.

    Should be marked with proper lighting and signs, andshould be easily visible.

    Since it becomes the main entrance for the hospital

    at night, it must relate to public and vehicular

    transportation.

    Close proximity to the radiology unit is essential to

    facilitate the movement of accident cases and save

    every precious minute.

    DESIGN OF EMERGENCY:Entrance to emergency should be sheltered to protect

    ambulance patients from the weather while unloading.Adequate reserved parking for ambulance and cars of

    patients and medical staff.

    Ambulance entrance should be large enough to admit

    one or more negotiating with stretchers.

    AUTOPSY ROOM AND MORTUARY:

    Facilities and space required in autopsy room is

    autopsy table work counter, storage room, cold

    storage and doctors office.The location of mortuary should avoid public

    movement.

    Functional Relationship Diagram

    Emergency Unit

    DIAGNOSTIC FACILITIES:

    DIAGNOSTIC AREA

    IMAGING SERVICE LABORATORY

    RADIOLOGY

    ULTRA SOUND

    C.T SCAN

    RECEPTION

    RECORD

    CLINICAL LAB

    FLOW CHART OF DIAGNISTIC

    The lab should be situated in the ground

    floorSo that it can serve emergency ,outpatient

    and the in patient department.It should be close to surgery, I.C.U.

    X RAY ROOM

    ULTRASOUND CT SCAN M.R.I

  • 8/10/2019 nikhil ppt.pdf

    14/45

    350 BEDDED GENERAL HOSPITAL AT SUSHANT GOLF CITY, LUCKNOW

    Submitted By:Prachi Gupta

    Roll No. - 817

    IIA Part-IV-Group-B (2014-15)

    PHISIOTHERAPY:

    The department is more frequently visited by out-

    patients but should be located at a place which may

    be at convenient access to both outdoor and indoor

    patients with privacy. It should also have a physical

    and electro-therapy rooms, gymnasium, office, store

    and toilets separate for male and female.

    ELECTROTHERAPY

    PHYSICAL MEDICINE AND REHABILITATION

    PHARMACY:

    Pharmacy should have component of medical store

    facility for indoor patients and separate pharmacy

    with accessibility for OPD patients.

    I.P.D. : OPERATION THEATRE

    One ot for every 50 general inpatient beds One ot for every 25 surgical beds.

    In the surgical department, treatment is given to the

    patients whose conditions have been diagnosed but

    cannot be cured solely with medication.

    There may be four well defined zones of varying

    degree of cleanliness/asepsis namely, Protective

    Zone, Clean Zone, Aspectic or Sterile Zone andDisposal or Dirty Zone. Normally there are three types

    of traffic flow, namely, patients, staff and supplies.

    FLOW CHART OF SURGICAL DEPARTMENT Other hospital areas

    PATIENT WARDS

    Post Operative

    recovery

    I.C.U.

    Operating rooms TSSU

    Anaesthesia roomSrub up

    Pre operative beds

    Doctors

    change

    room

    Nursess

    change

    room

    Instrumentstore

    CSSD

    PatientsDoctors Nurses

    OPERATION THEATRE

    CSSD

    PREPARATION ROOM

    INSTRUMENT STORE I.C.U

  • 8/10/2019 nikhil ppt.pdf

    15/45

    350 BEDDED GENERAL HOSPITAL AT SUSHANT GOLF CITY, LUCKNOW

    Submitted By:Prachi Gupta

    Roll No. - 817

    IIA Part-IV-Group-B (2014-15)

    I.C.U & H.D.U:

    It should be the ultimate medicare the hospital can

    provide with highly specialized staff and equipment.

    The number of patients requiring intensive care may

    be about 5 to 10 percent of total medical and surgical

    patients in a hospital. The unit shall not have less than

    4 beds nor more than 12 beds.

    LOCATION

    This unit should be located close to operation theatredepartment and other essential departments, such as,

    X-ray and pathology so that the staff and ancillaries

    could be shared.

    FACILITIESNurses StationClean Utility Area

    Equipment Room

    DAY CARE UNIT:

    The unit is for patients who need a surgical operationor clinical procedure but do not need to stay in

    hospital overnight, or who require an endoscopic

    procedure either as an inpatient or a day patient.

    PATIENT

    DAY CARE UNIT FLOW CHART

  • 8/10/2019 nikhil ppt.pdf

    16/45

    350 BEDDED GENERAL HOSPITAL AT SUSHANT GOLF CITY, LUCKNOW

    Submitted By:Prachi Gupta

    Roll No. - 817

    IIA Part-IV-Group-B (2014-15)

    FLOW CHART OF LABORATORY

    PATHOLOGY & BLOO BANK:

    Every hospital must have a blood bank under the

    drug and domestic rule 1974.

    2 labs and blood collection room should be provided

    and they all must be air conditioned.

    BLOOD BANK

    MICROBIOLOGY LAB

    BACTERIOLOGY

    VIROLOGY LAB

    MEDIA PREPARATION &

    STORAGE

    SEROLOGY LAB

    TOXICOLOGY

    FORENSIC MEDICINE LAB

  • 8/10/2019 nikhil ppt.pdf

    17/45

    350 BEDDED GENERAL HOSPITAL AT SUSHANT GOLF CITY, LUCKNOW

    Submitted By:Prachi Gupta

    Roll No. - 817

    IIA Part-IV-Group-B (2014-15)

    WARD BLOCK:

    The basic aim in planning a ward unit should be to

    minimize the work of the nursing staff and provide

    basic amenities to the patients within the unit. The

    distances to be traveled by a nurse from bed areas to

    treatment room, pantry etc. should be kept to the

    minimum. Ward unit will include nursing station,

    doctors duty room, pantry, isolation room, treatment

    room, nursing store along with wards and toilets asper the norms.

    Operation Theatre a. 1 OT for every 50

    general in patient beds.

    b. 1 OT for every 25

    surgical beds.ICU beds = 5 to 10 % of total beds

    Floor space for each ICU

    bed = 25 to 30 sqm (this

    includes support

    services)Floor space for paediatric

    ICU beds = 10 to 12 sqm per bed

    Floor space for high

    dependency Unit(HDU) = 20 to 24 sq m per bed

    Floor space hospital

    beds (general) =15 to 18 sqm per bed

    Beds space = 7 sq m per bedMinimum distance between

    centres of two beds = 2.5m (minimum)

    Clearance at foot end of

    each bed = 1.2 m (minimum)

    Minimum area for aperture

    (Window / ventilators opening

    in Fresh air) = 20 % of the floor

    area (if on same wall)

    = 15 % of the floor area

    (if on opposite walls)

    GENERAL WARD

    SERVICES:

    CENTRAL STERILIZATION AND SUPPLY DEPARTMENT

    (C.S.S.D):The sterilisation process may be carried out entirely or partially on-

    site, the latter relying on an external supply source to regularly

    restock the hospital sterile goods store/s. The scale of operation can

    be small or large, dependent upon the requirements of the serviced

    departments, for example, an Operating Unit requires the services of

    a Theatre Sterile Supply Unit (TSSU) or a full Central Sterile SupplyUnit (CSSU), whereas an Acute Inpatient Unit requires only a basic

    sterile supply service.

    Location:

    The cssd should be close to the casuality, operation theatre.In

    multistoried buildings cssd may be planned in the lower floor right

    under the operation theatre where vertical movement will be the

    quickest possible movement of the material.

    LAYOUT OF CSSD

  • 8/10/2019 nikhil ppt.pdf

    18/45

    350 BEDDED GENERAL HOSPITAL AT SUSHANT GOLF CITY, LUCKNOW

    Submitted By:Prachi Gupta

    Roll No. - 817

    IIA Part-IV-Group-B (2014-15)

    LAUNDRY:

    It should be connected to the power plant as it is the

    largest user of power, steam and water.

    It should be near the service elevator.

    FOOD SERVICE DEPARTMENT:

    A ground floor location is preferable. As it is

    convenient to deliver supplies.

    The storage area should be close to the unloadingdeck.The cafeteria and dinning area should be close to the

    food preparation and production area and within reach

    to the hospital reach.

    MEDICAL RECORDS:

    It should be close to the administration block.It should be conveniently close to the corridor leading

    to doctors lounge so that the staff can be

    conveniently stop by and complete their records.

    MEDICAL GASES:

    As oxygen is essential for life, events leading to

    hypoxic situation for the patient have to be treated

    immediately and carefully. Oxygen is given for

    treatment and prevention of a variety of a variety of

    cardiac, pulmonary and other diseases.

    Oxygen :

    This gas is used in general anesthesia in hospital all

    over the world. Due to analgesic effects,nitous oxideis also used in amixture with oxygen for analgesia in

    painful interventions in hospital environment(obstetric

    wards, dental surgery

    Nitrous oxide :

    Compressed air is required in hospital to operate

    surgical instruments such as pneumatic drills,saws,ot

    tables,etc.In orthopedics, dental and ent departments.

    Air is also used to run ventilators in OT and intensive

    care units and may be used as a carrier gas in

    amesthesis

    Medical Air:

    Carbon dioxide is used for varoius medical purpose

    such as insfflation gas for minimal invasive

    surgery(laparoscopy,endoscopy,arthroscopy)to

    enlarge and stabilize body cavities for better visibility

    of the surgical field.Carbon dioxide inliquid phase

    temperature as low as -76degree and may therefore,

    be used for cryotherapy or for local analgesia by

    external application into the skin surface.

    Carbon Dioxide:

    Besides the gases mentiones,it also provide a

    cantralized vaccum suction system at all outlet points

    which can be used lieu of portable suction machine

    and anesthetic gas scavengiring system for the

    excess anesthetic gases in ots.

    Vaccum Suction:

    EMERGENCY EXIT

    TOILET

    EMPTY

    CYCLINDER

    C

    O

    R

    R

    ID

    O

    R

    ENTRY

    ENTRY

    LAYOUT FOR MEDICAL GAS PLANT

    A GAS SYSTEM VACUUM SUCTION

    N0 MANFOLDCOMPRESSOR

    FOR MEDICAL

    AIR

    LIQUID O TANK

    O MANFOLD

    OFFICE

  • 8/10/2019 nikhil ppt.pdf

    19/45

    350 BEDDED GENERAL HOSPITAL AT SUSHANT GOLF CITY, LUCKNOW

    Submitted By:Prachi Gupta

    Roll No. - 817

    IIA Part-IV-Group-B (2014-15)

    AREA TEMPERATURE(DEGREE)

    OPERATING THEATRE 21-25

    DELIVERY ROOM 21-25

    RECOVERY ROOM 24

    NURSERY 24-26

    INTENSIVE CARE 24-26

    HVAC SYSTEM:

    There is a need for conditioning air in particular areas

    of the hospital to achieve certain level of temperature,

    humidity, filtration and circulation.

    The areas that require air-conditioning:

    Operating rooms, labour-delivery suites, icus,

    nurseries, morgues,

    Autopsy rooms.

    One major difference is that hospital air conditioning ismore attained to patient and patient treatment rather

    than comfort.

    WATER SUPPLY AND SANITARY SYSTEM:Water requirement of hospital :

    The minimum requirement of water supply for an

    hospital shall be in accordance with the national

    building code(NBC).

    Hospital (including laundry )per bed.Number of bed not exceeding 100 = 340

    litre per head per day

    A) Number OF BEDS EXCEEDING 100 = 450

    LITRE PER HEAD PER DAY

    B) Nurses/MEDICAL STAFF QUARTERS = 135

    LITRE PER HEAD PER DAYC) Minimum HOT WATER REQUIREMENT = 45

    LITRE PER HEAD PER DAY

    S.NO. FITMENTS I.P.D (M/F) O.P.D .MALE O.P.D FEM. ADMIN (M) ADMIN (F)

    1. W.C 1 FOR 6 BED 1 PER 100 2PER 100 1 PER 25 1 PER 15

    2. WASH BASIN 1/24PERSON &

    1/24 BED

    1 PER 100 1 PER 100 1 PER 24 1 PER 25

    3. BATH WITH

    SHOWER

    1 PER EVERY 6

    BED

    ------ ------ 1 PER FLOOR 1 PER FLOOR

    4. BED PAN 1PER 6BED

    WARD

    ------- ------- ------ -------

    5. CLEANER SINK 1 PER EACH

    WARD

    1 PER FLOOR 1 PER FLOOR 1 PER FLOOR 1 PER FLOOR

    6. KITCHEN SINK 1 PER EACH

    WARD

    ------ ------ ------ -----

    7. URINALS 1PER 20 PERSON 1 PER 50

    PERSON

    ------- 1/20PERSON+2.

    5%

    1/20PERSON+2.

    5%

    Norms for fitments:

    ELECTRICAL SERVICES:

    Electricity service should be available 24 hour a day. There should be power back up

    system as per requirement.

  • 8/10/2019 nikhil ppt.pdf

    20/45

    350 BEDDED GENERAL HOSPITAL AT SUSHANT GOLF CITY, LUCKNOW

    Submitted By:Prachi Gupta

    Roll No. - 817

    IIA Part-IV-Group-B (2014-15)

    BIOMEDICAL WASTE:

    Biomedical waste, (bmw), consists of solids, liquids,

    sharps, and laboratory waste that are potentially

    infectious or dangerous and are considered biowaste..

    It must be properly managed to protect the general

    public, specifically healthcare and sanitation workers

    who are regularly exposed to biomedical waste as an

    occupational hazard.

    COLOUR CODING AND TYPE OF CONTAINER FOR DISPOSAL OF BIO-MEDICAL WASTES

    This bag is used for collecting dry waste material

    which is not infectious. Materials like paper, plastics,

    cardboard boxes, and other dry waste generated in

    hospital office or in the wards are disposed in this bag.

    This is not biomedical waste.

    Black Bag :

    This bag is used for the disposal of plastics collected

    from ots, icus and wards.

    Red Bag :

    This bag is used for highly infectious items like

    pathological waste, human anatomical waste such as

    body parts, amputated parts/organs, tumors,

    placentas, aborted or dead fetuses ,blood soaked

    cotton bandages, animal tissues, organs, carcasses

    etc.

    Yellow Bag :

    This bag is used for collecting the segregated metal

    sharps such as needles, blades, saws, scalpels and

    glass pieces.These bags must be puncture proof.A metal box or a plastic canister should be used

    for collecting the metal sharpsIt is strongly recommend that even metal sharps

    and broken glass articles should be segregated.Broken glass sharps should be collected in blue/

    white bags.

    Lead containers:

    These containers are used for collecting radioactive

    wastes

    This waste is to be disposed as per the guidelines

    provided by bhabha atomic research centre (barc),

    mumbai.

    Radioactive wastes, especially cobalt needles usedfor brachy treatment must be returned to barc.

    Cytotoxic waste can be stored in sturdy cardboard

    boxes and later can be incinerated.

    Blue or white opaque Bag :

  • 8/10/2019 nikhil ppt.pdf

    21/45

  • 8/10/2019 nikhil ppt.pdf

    22/45

    350 BEDDED GENERAL HOSPITAL AT SUSHANT GOLF CITY, LUCKNOW

    Submitted By:Prachi Gupta

    Roll No. - 817

    IIA Part-IV-Group-B (2014-15)

    Case Study 1: Sahara Apollo Hospital,Lucknow

    The 550 bedded hospital spread on an area of 27 acres, is planned to

    offer services in more than 52 specialities, super specialties anddiagnostic modalities under one roof complete diagnostic solution.

    Distance from railway station is 9km.,Distance from Hazratganj is

    7.2km.

    Location :Haniman Chauraha ,Gomti Nagar, Lucknow.

    Client :Sahara india Parivar

    Architect :Architect Hafeez Contract. Archimedes cons. Pvt. Ltd.Site area : 27 acres

    Built up area : 74000 Sqmtr

    Cost of project : 400 Crores+

    No. Of beds : 550

    Completion : 2008

    Site is located in gomti nagar, a newly developed area in lucknow.

    On the west there are institutes.

    On the east is the residential belt.On the north is a stretch of commercial land.

    On the south runs a railway line and further back is the residential

    stretch.

    Sahara hospital lucknow :

    About hospital :

    Approach to hospital :

    Project brief :

    Site surrounding :

    Railway line

    24 mtr wide main road

    Sahara hospital is situated in gomti nagar ,Lucknow,U.P.

  • 8/10/2019 nikhil ppt.pdf

    23/45

    350 BEDDED GENERAL HOSPITAL AT SUSHANT GOLF CITY, LUCKNOW

    Submitted By:Prachi Gupta

    Roll No. - 817

    IIA Part-IV-Group-B (2014-15)

    The main acess is from 24 mtr wide road on two side. Of

    which otherside of the road is Gomti Nagar commercial

    Plots with no. Of small malls at other vicinity is filled with

    residential area.There are two entry from south i.e. one for emergency

    and other for OPD and doctors.One entry is from east side for exit for OPD and doctor.

    One entry is from north east for service entry .

    This hospital is indias first 7 star rating multi speciality

    tertiary care hospital of an estimated capacity 550 beds

    located in lucknow .It is estimated to care for almost 3 lakh

    people with its OPD and 50000 patents through IPD

    anually.

    To understand the designing of a specialty hospital and to

    analyse and understand the issues and technicalities

    associated to it and its merits.

    The L-shaped 4 storeyed building high, block houses the

    diagnostic zone in one arm and OPD in other.

    The 16 storey high tower is the patients tower rising

    from the center and is fronted by a double height lobby,

    which function as the entrance foyer for all the zones.

    Two organically shaped double heighted atrium emerge

    from the main foyer.The interior are highlighted by the sunny

    vistas,closeness to nature and soothing materials.

    Acess to block :

    Validity of the study:

    Objective of the study :

    About block organization :

    N

    Entry for

    emergency

    Entry for opd

    Entry for service

    Exit for opd

  • 8/10/2019 nikhil ppt.pdf

    24/45

    350 BEDDED GENERAL HOSPITAL AT SUSHANT GOLF CITY, LUCKNOW

    Submitted By:Prachi Gupta

    Roll No. - 817

    IIA Part-IV-Group-B (2014-15)

    Parking :

    Basement parking is provide for 350 cars.

    Basement parking is underneath the large and open green

    space and is accessed by means of 2 ramps on either ends.

    Parking is categorized as follows :

    1.Ambulatory 5 in nos. At the emergency exit

    2.Staff/vip behind the linear block on the surface.

    3.Visitor at basement

    Circulation :

    Entry is provided from the middle of the parking site.

    Public is restricted to a certain extent in the building so as to

    prevent them from interfering in the privacy of staff, nurse and

    doctors.Horizontal circulation is done through corridors.

    Vertical circulation by means of lifts and staircase.

    Design consideration :

    The l shaped storeyed high block houses the diagnostic zone

    in one arm and OPD in another.

    The 16 storeyed high tower is the patientstower rises from

    the center and is fronted by a double height lobby, which

    functions as the entrance foyer for all the zones.

    Two organically shaped double height atrium emerge from

    this main foyer.

    The interiors are highlighted by the sunny vistas, closeness to

    nature and soothen materials.

    The service block is separate and linked by a bridge.

    More green area is left for better environment i.e about 75 %

    area is green area.

    Sales

    GREEN AREA

  • 8/10/2019 nikhil ppt.pdf

    25/45

    350 BEDDED GENERAL HOSPITAL AT SUSHANT GOLF CITY, LUCKNOW

    Submitted By:Prachi Gupta

    Roll No. - 817

    IIA Part-IV-Group-B (2014-15)

    GREEN AREA

    EMERGENCY/

    TRAUMA

    ATRIUM

    ATRIUM

    ENTRANCE

    LOBBY

    DIAGNOSTIC

    RECEPTION

    O.P.D

    SERVICE

    APARTMENT

    IPD TOWER

    SERVICE

    BLOCK

    WAY TO BASEMENT PARKING

    EMERGENCY

    ENTRY

    OPD

    ENTRY

    OPD

    EXITSERVICE

    ENTRY

    Site zoning :About function:

    Entrance to the site is from north east as

    well as from south east.The site is almost of a 1:2 proportion;

    diagonally and the portion that makes up the

    foreground caters to the adequate landscape

    elements with underground parking beneath it.

    The main hospital structure is located in thesecond notional portion of the site i.e. on the

    back ground stretching towards the south

    west.

    The service block is located in the south

    west corner of the site.Provision for morgue has also been provided

    next to service block on the extreme south

    west corner.

    Provision has been made for patient relative

    accommodation on the northwest region of the

    site.A connecting bridge connecting the service

    and the tower block is also present.

    About planning :

    Ground floor :

    Diagonostic :Two entries ,one main and one from the wing perpendicular to O.P.D.

    Multi entries to all the daignostic areas.

    Linear block consists of three zones in ground floor that are :

    1.Emergency O.T , triage rooms ,plaster rooms ,physiotherapy ,dialysis

    and consulting rooms.

    2.Diagnostic radiology ,ct scan

    3.Pathology labs , administration.

    All the above areas have separate entriesconnected via an atrium and are inter connected

    by 2.4 m doubly loaded corridor.

    All the wings are connected with 2.4 mtr

    corridor.

    IPD

  • 8/10/2019 nikhil ppt.pdf

    26/45

    350 BEDDED GENERAL HOSPITAL AT SUSHANT GOLF CITY, LUCKNOW

    Submitted By:Prachi Gupta

    Roll No. - 817

    IIA Part-IV-Group-B (2014-15)

    All the above areas have separate entries connected via

    an atrium and are inter connected by 2.4 m doubly loaded

    corridor.

    All the wings are connected with 2.4 mtr corridor.

    The placing of block in l shaped reducing the 30 %

    circulation area.

    At every 30 mtr distance in corridor there are fire exit .

    Proper waiting area provided in all the facilities.

    Lift is provided at the center as well as at the corner.

    CIRCULATION AREA, LIFT LOBBY, RECEPTION,

    EXAMINATION ROOM

    G.FR. PLAN (O.P.D )

    1

    1

    2 3 4 5 6 7 8 9 10

    11 12 13 1314 14

    GROUND FLOOR PLAN

    (DIAGNOSTIC BLOCK)

    2.4 M WIDE CORRIDOR

    LIFT LOBBY

    PATIENT LIFT LOBBY

    LIFTLOBBY

    RECEPTIONWAITING

    ORTHOPAEDICROOM5

    NEORO SURGERYCONST.3

    NEURO PHYSICIAN3

    RECEPTIONBACK SIDE

    OPD

    IPD

    ENTRANCE

    LOBBY

    N

    EMERGENCY ENTRY

    MAIN ENTRY

    DIAGNOSTIC

    OPD

    IPD

    ENTRANCE

    LOBBY

    EMERGENCY ENTRY

    MAIN ENTRY

    GROUND FLOOR PLAN

    EMERGENCY:

    Emergency is 12 beded in which 6 are for criticalpatient,

    6 are for observation, two are triage.

    One O.T is there with plaster room and procedure

    room.

    It has one nurse station and pharmacy store.

    It has one counseling room.It has one linen room attached with equipment room.

    Front block of 4 tier structure houses O.P.D block.

    Simple in both planning and service than I.P.D anddiagnostic block.Main entry is from the parking area.

    Directly connected to the atrium and having its own

    reception.

    Distribution in all four floors are similar in design.

    O.P.D :

    Area of doctor consultance room is

    2950x3700mm

    Area of exam. Room is 2950 x 2400 mm.

    Area of O.P.D:

    N

    O.P.D (specialty

    facilities per floor):

    GROUND FLOOR

    INTERNAL MEDICINE

    ORTHOCARDIO

    BRONCHIOLOGY

    PULMONARY

    PLASTIC SURGERY

    NEURO

    PLASTER ROOM

    FIRST FLOOR

    OPTHAMOLOGY

    OBSTETRICS

    ENDOCRINEOLOGY

    PAEDIATRIC

    OPTICAL SHOP

    SECOND FLOORGATRO

    AYUVEDIC

    DERMATOLOGY

    UROLOGY

    NEPHROLOGY

    E.N.T

    PHYCHIATRIC

    THIRD FLOOR

    AROMA THERAPY

    PANCH KARMA

    OPD

    First floor :

  • 8/10/2019 nikhil ppt.pdf

    27/45

    350 BEDDED GENERAL HOSPITAL AT SUSHANT GOLF CITY, LUCKNOW

    Submitted By:Prachi Gupta

    Roll No. - 817

    IIA Part-IV-Group-B (2014-15)

    First floor :

    Facilities provided in first floor:

    Operation Theatre

    Pre operative room

    Surgical I.C.UStaff area

    C.S.S.D

    Day Care Unit

    H.D.U

    Operation Theatre Zone :Placed at the end of first floor with diagnostic

    facilities just below it and I.C.Usadjacent to it.

    Separate entry for patient, doctors and I.C.U..

    Isolated from rest of the hospital hence

    minimum traffic flow.

    10 O.T present with shared support facilities.Its own sterile area between clinical and ward

    zone.

    Intensive Care Unit :120 bed C.U is placed adjacent to O.T

    complex on first floor placed in doubly corridor.

    Comprises of 11 bedded M.I.C.U ,12 beded

    surgical I.C.U ,12 bedded neuro I.C.U, 4 beded

    transplant I.C.U and coronary I.C.U.I .C.U are attached to the cath lab.

    Centrally located nurse station with central

    monitoring system.

    High Dependency unit:Direct related to nurse station.

    8 beded high dependency ward with attachedtoilet is provided.

    Artificially lighted and ventilated.

    OT

    OT

    OT

    PRE OPERATIVE S.I.C.U C.C.U

    CATH LAB

    STAFF

    AREASTAFF

    AREA

    CSSD TRANS.

    I.C.U

    I.C.UWAITING

    WAITING

    DAY

    CARE

    HDU

    FIRST FLOOR PLAN (O.T ZONE)

    GENERAL

    WARD

    GENERAL

    WARD

    GENERAL

    WARDGENERAL

    WARD

    GENERAL

    WARD

    GENERAL

    WARD

    ISOLA

    TION DELUXE DELUXEDELUXE DELUXE

    PRIVATE

    WARD

    PRIVATE

    WARD

    SEMI

    PRIVATE

    WARD

    SEMI

    PRIVATE

    WARD

    SEMI

    PRIVATE

    WARD

    SEMI

    PRIVATE

    WARD

    5THFLOOR PLAN ( 2 LVL) 6THFLOOR PLAN ( 3 AND 4LVL)

    30I.C.U

    Area of general ward : 9000x7350mm

    Private room : 3500x 3650mm

    Semi private room : 4550 x 3675mm

    Deluxe room : 3675 x 3650 mm

    Semi delux room; 3675x 3500

    GENERAL WARDS

    SEMI PRIVATE

    WARDS

    PRIVATE WARDS

    SEMI DELUXE

    DELUXE

    150

    70

    30

    15

    5

    30I.C.U

    P.D and General Wards :

    15 storeyed tower houses the I.P.D and

    general ward ,placed on the junction of

    the blocks.Compact square is adopted

    Patient and visitor entry is from the

    same corridor of width 2.4m.

    Nurse station ,service lifts are placed in

    the same corridor.Beds are placed along the periphery to

    have maximum ventilation and light.

    Piped oxygen and suction is provided in

    each ward.

    Spacious rooms are separated from the

    other rooms.

    Two nursing station are provided .Six

    bedded general wards placed in tower of

    two floors.

    Units are inter connected with the toilet

    at the end.

    For privacy curtains are used.

    Semi private wards:Room with two beds and attached toilet.

    Balcony and curtain for privacy.Equipped with all facilities and sixth floor.

    Private Wards:Consists of a patient room with attached toilet and pantry.

    Bed is totally remote control.Deluxe room:Single deluxe ,deluxe and semi deluxe suit are located in

    the center with all the services in central core.

    Rooms with attached toilet ,balconey and sofa cum bed

    is alloted.

    Maternity and Neonatal I.C.U :Located on the first floor of the tower.

    Consists of two labour rooms.Nurse station and other services are provided

    in the central core.Neonatal I.C.U is bedded with all latest

    technology technology and mother feeding

    room.

    No.of O.T , No.Of Beds and No. of Consultant in different specilitation :

  • 8/10/2019 nikhil ppt.pdf

    28/45

    350 BEDDED GENERAL HOSPITAL AT SUSHANT GOLF CITY, LUCKNOW

    Submitted By:Prachi Gupta

    Roll No. - 817

    IIA Part-IV-Group-B (2014-15)

    No.of O.T , No.Of Beds and No. of Consultant in different specilitation :

    Services:Water supply :

    Total water tank 7 that are :

    1.25 lakh ltr 5 tank and2 tank of 2 lakh ltr.

    Note : 2 tank of 2 lakh ltr capacity are for

    fire.

    Water treatment plant :

    2 for filtration of capacity 15000 ltr.2 for boiler of capacity 15000ltr.

    2 for raw water

    2 for cosmetic

    2 for soft water

    Hydro pneumatic system :

    3 set of two pump.

    Note : 8 pump other to above are for fire.

    BED

    O.T

    CONSULT.

    80

    2

    8

    60

    2

    6

    60

    2

    6

    50

    2

    6

    40

    2

    4

    40

    1

    1

    GENERAL MEDICINE GYNAE & OBTETRICS PEDRIATIC & NEONATAL ORTHO & LIMBS E.N.TCARDIO

    HOSPITAL

    Drainage:14 sump pumps are locatedin the

    basement.

    Electrical :Total consumption 15 kw for

    emergency.

    Ups :300 kva (2) 200 kva (2)

    Dg set : 1500kva 3 set 2000 kva 2 set

    Electicity load:

    1300 amp in winter

    1700 amp in summer

    H.V.A.C ;700 ton chiller of 3 in no.

    Note : in summer 2 no. of chiller work

    And in winter only one is in working.

    Biomedical waste flow chart :

    HDU

    OT

    OT

    OT

    PRE OPERATIVES.I.C.U C.C.U CATH LAB

    STAFF

    AREA

    CSSD TRANS.

    I.C.U

    I.C.U DAY

    CAREBIO.WASTE

    SERVICE ENTRY

    Bio gas flow chart :

    Laundary & kitchen Service:

    Laundary is on the first floor of service block .

    Laundary has 5 washing machine, 4 slucing

    machine, and 4 hydro extractor.

    Kitchen has an veg,non veg zone, patient liquid

    food zone,cafeteria preparation zone.

    It has a 45 staff dinning attached to it and 55 for

    people.

    Medical oxygen

    Nitrous oxide

    Vacum suction

    Carbondioxide

    MEDICAL GASOT

    PRE OPERATIVE S.I.C.U C.C.U CATH LAB

    CSSD TRANS.

    I.C.U

    I.C.U DAY

    CAREHDU

    LAUNDARY

    Gas station is placed at the back of the kitchen.

    20-22 commercial cyclinder is the per day

    consumption.

  • 8/10/2019 nikhil ppt.pdf

    29/45

    350 BEDDED GENERAL HOSPITAL AT SUSHANT GOLF CITY, LUCKNOW

    Submitted By:Prachi Gupta

    Roll No. - 817

    IIA Part-IV-Group-B (2014-15)

    HT PANELBOILER

    ROOM

    L.T PANEL

    HT PANEL

    STORE

    D G SET

    A.C PLANT

    OFFICE

    GAS PLANT

    BIO.WASTE

    Sercive ground floor plan

    KITCHEN

    STAFF DINING

    MEDICAL

    STORESTAFF LOCKER

    Sercive first floor plan

  • 8/10/2019 nikhil ppt.pdf

    30/45

  • 8/10/2019 nikhil ppt.pdf

    31/45

    350 BEDDED GENERAL HOSPITAL AT SUSHANT GOLF CITY, LUCKNOW

    Submitted By:Prachi Gupta

    Roll No. - 817

    IIA Part-IV-Group-B (2014-15)

    INFERENCES :

    Adequate waiting area in all departments

    Atrium houses a large number of visitors and has different accesses to different departments thereby restricted the flow of visitors to this areas only.

    The service block forms the major hub for hospital functions, without the interference of the main stream of the hospital.

    Segregation of visitor, staff and service entry.

    Separate service lift for food, linen, staff, visitors and patient help to avoid congestion.

    Flexibility for the future so that any floor could be converted from wards to rooms and vice versa.Toilets are designed according to the needs of patient.

    Emergency evacuation is not catered for since there is no provision of a ramp.

    Lack of natural light and ventilation in lower floors.No dirt disposal corridor in the O.T. complex.

    Increase in the cost because of introduction of service floors in the building.Service floors create better floors usability as area in services is segregated on floors.

    Service floors gives design flexibility as services considerations in design are reduced.

    CASE STUDY 2 R M h L hi G ti L k

  • 8/10/2019 nikhil ppt.pdf

    32/45

    350 BEDDED GENERAL HOSPITAL AT SUSHANT GOLF CITY, LUCKNOW

    Submitted By:Prachi Gupta

    Roll No. - 817

    IIA Part-IV-Group-B (2014-15)

    CASE STUDY 2 - Ram Manohar Lohia, Gomti nagar, Lucknow

    Ram Manohar Lohia HospitalLocation : Vibhuti Khand, Gomti Nagar at Lucknow

    Site Area : 25 Acre

    Ground Coverage : 20,000 sq m. (30.7%)

    Year of Completion : 2007

    Introduction

    Ram Manohar Lohia combined hospital is located in

    Vibhuti Khand, Gomti Nagar.

    Access is from 30m wide road which further joins to the

    60m wide main road.

    In front of its main entry is the Punjab National Bank

    Institute, Mandi Parishad and UPRNN head office.

    In front of its OPD entry is the rear side of WAVES

    multiplex.

    The hospital serves as a referral centre for the populationof Lucknow and populations from adjacent districts as well

    as belt of Eastern U.P.

    The diagnostic services at the institute are state of art in

    health care and the Department of Pathology and

    Microbiology have been upgraded to State Referral Centre

    for Laboratory Investigation.

    Department of Radiology has high-end facilities with a

    comprehensive 64 slice CT scan, 3 Tesla MRI, BMD,

    mammography etc.The hospital is networked by a all- inclusive web-based

    HIS system which provides electronic records from

    registration to discharge.The administrative wing comprises of the Director,

    Finance controller and Engineers in Engineering divisions

    and Joint Director Material Management.

    Main Display Board

    About Planning :

  • 8/10/2019 nikhil ppt.pdf

    33/45

    350 BEDDED GENERAL HOSPITAL AT SUSHANT GOLF CITY, LUCKNOW

    Submitted By:Prachi Gupta

    Roll No. - 817

    IIA Part-IV-Group-B (2014-15)

    About Planning :

    The basic planning of Ram Manohar Lohia Hospital is

    the concept of placement of various functions space

    along the two corridor.

    Along one corridor OPD , Diagnostic facilities,

    Pathology Services, Emergency, ICUs, OTs are

    placed whereas along second IPD blocks are placed.These two corridors are separated by open spaces

    between them .

    Ramps are projected out in these open spaces.

    There is separate entrance for individual blocks but

    interconnected through straight running corridors.All services are clubbed together and placed at rear

    end.

    Patient relatives blocks are also provided to

    accommodate the relatives of patients and also

    manage the crowd of hospital.Ample space is left for landscaping but not fully

    developed by the authority.

    Building is north-south oriented according to thecomposite climate of Lucknow.

    OPD BLOCK

    Double height waiting area in centre and

    consultant examination room at side

    Every OPD have its individual space.

    Registration counter in front of the entrance

    hence clearly visible.

    Space for making queue is provided in front of

    the counter.Separate entrance for OPD provided from side

    road.

    Skylight in the central waiting space for light andventilation.

    DIAGNOSTIC BLOCK

  • 8/10/2019 nikhil ppt.pdf

    34/45

    350 BEDDED GENERAL HOSPITAL AT SUSHANT GOLF CITY, LUCKNOW

    Submitted By:Prachi Gupta

    Roll No. - 817

    IIA Part-IV-Group-B (2014-15)

    Rooms are placed at the periphery so that itcan have natural light and ventilation.

    Pay ward had separate entry at the ground floor.

    The rooms are located at the periphery and the

    toilets at the one end in between the wardsNurses station, DU, CU, treatment room, nurse rest

    room, toilet, doctor room provided in the middle.Separate staircase is for services and one lift too is

    proposed for that.

    Pay ward have contain single bedded room with

    attach toilet.

    MAIN BLOCKMain entrance to the hospital is through

    central wing.

    It has administration the first, second floor

    and entrance at the ground floor through spiral

    staircase the left side of the entrance lobby.

    Entrance lobby is of double height.Left side of the central wing is the radiology at

    the ground floor and pathology at the first floor.

    This not been constructed yet.

    At the right side is the maternity deptt. On

    ground floor and ICCU, ICU at the first floor.

    DIAGNOSTIC BLOCK

    Physiotherapy deptt. is places at the ground

    floor and dialysis at the first floor.

    Ample waiting space in front of the deptt.

    The deptt. is equipped with latest

    equipments.

    Has corr idor running on its two sides, one

    leads to the ward and the other leads to the

    main entry.

    Three hospital lifts are present, no passenger

    lift, as it is only storey.

    Toilets ventilated in open court and placed

    along the long straight corridor running across

    the whole hospital.

    There are 3 IPD blocks, one contains pay

    wards and other two are general wards.

    Emergency / Casuality

  • 8/10/2019 nikhil ppt.pdf

    35/45

    350 BEDDED GENERAL HOSPITAL AT SUSHANT GOLF CITY, LUCKNOW

    Submitted By:Prachi Gupta

    Roll No. - 817

    IIA Part-IV-Group-B (2014-15)

    Emergency / Casuality

    Adjacent to ICCU, ICU unit is emergency block.

    it has separate entrance and at the rear end of

    the hospital beside service block.

    As Pathology and Radiology department is not

    constructed, temporary pathology is in emergency

    block.

    Two CTs are in emergency block at groundfloor.

    OT ComplexSeparate entrance for doctors and patient.

    Visitorsentry is prohibited in OT complex.

    There are 6 OTs with dirty corridor running

    along its periphery.

    This dirty corridor then join to the staircase

    which leads to the ground floor directly without

    creating any cumbersome within the hospital area.

    The dirty contain disposable bay which is shared

    by two OTs.it has post operative room outside the OT

    complex and pre operative inside of it.

    Nurses station is located as such , that nurses

    can look after all patients.

    Doctors and nurses enter into OT through their

    changing room.Doctors and nurses lockers are also present.

    Emergency Block

    O.T. View

    Supply of gases

    Automatic system for washing hand

    Digital machine for

    temp, , time &

    emergency callingTo open the door ,to enter in O.T.touch pad.

  • 8/10/2019 nikhil ppt.pdf

    36/45

    350 BEDDED GENERAL HOSPITAL AT SUSHANT GOLF CITY, LUCKNOW

    Submitted By:Prachi Gupta

    Roll No. - 817

    IIA Part-IV-Group-B (2014-15)

    Circulation spaces

    Horizontal circulation is prominent and main feature

    of the hospital.

    The corridor of 3 mt. width run across the various

    departments.

    Vertical circulation is through staircase, lifts and

    ramps.2 hospital and 3 passenger lifts are provided.

    Service staircase is separately provided.2 ramps of 1:10 slope is provided.

    Services

    Electric supply from power corporation limited, UP. As a stand by there is one DG set of 125kv

    capacity.

    Water stored in underground tanks by using 2 bore

    wells.

    There are 3 hand pumps to supply drinking water to

    the patient relativesand other visitors.

    All services are placed at rear end and connected tohospital through corridors.

    Structural analysis

    Column grid of 6.4m x 6.4m in all blocks.

    Floor to floor height is 3.6m at each floor.

    Beam depth is 600 mm.

    SPIRAL STAIR CASE LARGE AND WIDE CORRIDORS

    STERLIZING OF EQUIPMENTSELECTRICAL SUPPY

    PARKING

  • 8/10/2019 nikhil ppt.pdf

    37/45

    350 BEDDED GENERAL HOSPITAL AT SUSHANT GOLF CITY, LUCKNOW

    Submitted By:Prachi Gupta

    Roll No. - 817

    IIA Part-IV-Group-B (2014-15)

    Parking in front of every block entry.Separate parking for staff and patient and visitors provided.

    All parking is on surface.

    MATERIAL

    Washed grit finish in white cement and marble chip in exterior.

    The exterior finish is maintenance free.

    Floor finishes by Kota stone in the circulation spaces and mosaic

    tile in the remaining spaces.

    Wall finishes is provided by plain plaster with white wash.

    INFERENCE

    All the spaces should be connected to each other.Every deptt. should have natural light and ventilation.

    Sufficient waiting spaces should be provided in OPD block.

    Emergency entrance should be close to the main entrance and

    free from any hindrance.Emergency, OT, ICU, Diagnostic facilities should be closed to

    each other.Diagnostic facilities should also be closed to the OPD.

    SUPPLY OF OXYGEN AT EMERGENCY TIME

    TO DISINFECT THE EQUIPMENT

    CONCEPT

  • 8/10/2019 nikhil ppt.pdf

    38/45

    350 BEDDED GENERAL HOSPITAL AT SUSHANT GOLF CITY, LUCKNOW

    Submitted By:Prachi Gupta

    Roll No. - 817

    IIA Part-IV-Group-B (2014-15)

    A hospital is a building which once starts working

    difficult to make alteration. Therefore require great

    focus while designing. Architects must have good idea

    of advancements of the medical and hospital needs.

    The major focus while designing should be on the

    inter relationship of the spaces and volumes.

    Connectivity and segregation of spaces. Differentiate

    the movement of patient ,doctor, staff and visitors etc.

    Functioning of the hospital is also very importantissue to be considered from very beginning while

    designing. Services are the heart of hospital.

    SEGREGATION OF MOVEMENTS

    There are 4 entries provided in hospital

    1. Main entry also as O.P.D entry which is given

    from 30.0 mt. wide road on south west side.

    2. Emergency entry is given at north which is

    assessed by 45.0 mt. wide service road andclearly visible from Amar shaheed path.

    3. Staff and doctors entry is given from south east

    side, as there residences are also provided in

    same direction.

    4. Services entry is provided at east corner of

    hospital block.

    9.0mt. wd road

    30.0mt.Wdroad

    Commercialland

    EMERGENCY

    ENTRY

    O.P.D ENTRY

    SERVICES

    ENTRY

    STAFF &

    DOCTORS

    ENTRY

    SEPERATING NOIST & QUITE ZONE

    Noist area like service zone and quite area like O.T.

    & wards should be placed at distance.

    O.TSERVICES

    WARDS WARDS

    O.T

    SERVICES SERVICES

    EMEREGCY

    MATERNITY

    O.T.

    WARDS

    ZONING OF THE BLOCKS

    Hospital is designed as two blocks of O.P.D & I.P.D.

    O.T.

    I.C.U

    SECOND FLOOR

    WARDS

    TYPICAL FLOOR

    W

    ARDS

    O.P.D

    EMERGENCY

    O.P.D

    DIA

    GONOSTIC

    GROUND FLOOR

    KITCHEN

    O.P.D

    MATERNITY

    O.P.D

    LABORATORY

    FIRST FLOOR

    N.I.C.U

    SERVICES

    BASEMENT

    SERVICES

    PHISIOTHERAPY

  • 8/10/2019 nikhil ppt.pdf

    39/45

    350 BEDDED GENERAL HOSPITAL AT SUSHANT GOLF CITY, LUCKNOW

    Submitted By:Prachi Gupta

    Roll No. - 817

    IIA Part-IV-Group-B (2014-15)

    A hospital is a function oriented building.

    Its function decides its form.

    Form follows function.

    CREATING A BUFFER ZONE AT ENTRACE

    Buffer zone from the road will help to reduce the

    noise of traffic.Huge trees at entry side will help to reduce noise

    and pollution.

    9.0mt. wd road

    30.0

    mt.Wdroad

    Commercialland

    GREEN PARK

    ORIENTATION

    The chief aim of orientation of building is to provide

    physically & psychologically comfortable living inside

    the building by creating the condition which suitably

    and successfully ward of the undesirable effects of

    severe weather to considerable extent .

    The prevailing flow towards the south east directionthrough major part of the year.

    The building is oriented in such a way that a

    maximum no. of opening should get the natural north

    light max. number of opening should be north side.

    KITCHEN

    O.P.D

    EMERGENCY

    O.P.D

    DIAGONOSTIC

    GROUND FLOORNW

    SE

    MATERNITY

    O.T.

    WARDS

    LABORATORY

    N.I.C.U

    I.C.U

    WARDS

    PARKING

    Separate parking space for the doctors and

    staff.

    Separate parking for ambulance is made in

    emergency.

    Basement parking and surface parking is

    also provided for visitors.

    BLOCK CONNECTIVITY

    Diagnostic is placed as it is closer to both

    O.P.D & Emergency.

    Emergency, maternity, O.T, complex and

    wards are placed one above another in

    sequence so that to make better vertical

    connectivity through lifts.

    Services are placed in basement and

    separate lifts are provided so that a quickservices can be provided without any

    hindrance.

    PLANNING CONCEPT

  • 8/10/2019 nikhil ppt.pdf

    40/45

    350 BEDDED GENERAL HOSPITAL AT SUSHANT GOLF CITY, LUCKNOW

    Submitted By:Prachi Gupta

    Roll No. - 817

    IIA Part-IV-Group-B (2014-15)

    GROUND FLOOR

    A huge entrance hall is provided at entry with double height lobby.At entry in front there is a may I help you counter where a unknown person

    can find a suitable path. Behind the counter wall a beautiful mural is provided

    which gives pleasant look to the lobby.

    Further there is reception on left side and pharmacy counter on right side.

    O.P.D BLOCK

    OPD block is provided on both side of entrance hall.

    In OPD block each consult room room is provides as below layout pattern.

    TYPICAL CONSULT ROOM LAYOUT FOR O.P.D

    EMERGENCY BLOCK

    Proceeding further from entrance hall towards front with 7.0 mt. wide

    corridor.

    This corridor also act as main corridor which connect each block with

    one another.

    Moving further on this corridor at left side emergency block is placed.

    Emergency block is provided with separate entry on north side of siteplan.So, that a minimum time is loss.

    At entry to emergency a reception, nurses station and doctorson duty

    is placed in front so that a quick service can be provided.Further a triage followed by x ray, emergency lab, and plaster room.

    If patient is in very critical condition then can be directly taken to

    emergency O.T. which is provided in emergency block.

    DIAGNOSTIC BLOCK

    It is provided in front of emergency block.Diagnostic block is placed in such a way so that it remain in direct

    connected with emergency and OPD block.

    KITCHEN & CAFETERIA

    Kitchen at south east side of building block.

    Hospital kitchen for inpatient wards is kept separate from kitchen &

    cafeteria for staff.. A dietician is also provided in ward patient kitchen, so that a proper

    guidance can be provided.

    FIRST FLOOR

    O P D block is provided as below in ground floor

  • 8/10/2019 nikhil ppt.pdf

    41/45

    350 BEDDED GENERAL HOSPITAL AT SUSHANT GOLF CITY, LUCKNOW

    Submitted By:Prachi Gupta

    Roll No. - 817

    IIA Part-IV-Group-B (2014-15)

    LABORATORY BLOCK

    Laboratory is provided just above diagnostic block.It is provided with sample collection , blood bank, and other labs like,

    microbiology, biochemistry, hematology, immunology.

    A media preparation and washing area is also provided.

    MATERNITY WARD, NICU, PICU

    Maternity ward, NICU & PICU is provided in first floor and is internally

    connected with maternity complex.

    SECOND FLOOR

    O.T. BLOCK

    O.T. block is provided above maternity block.

    There are 4 O.T.s are provided with shared services at mid.

    Dirty corridor is connected with each O.T. block which further leads to

    dumb waiter.Planning is based on double corridor system in which sterile corridor is

    kept separate from non sterile corridor.

    WAITING AREARECEPTIONSERVICE LIFT

    PRE LABOUR ROOM

    POST LABOUR

    & NURSERY

    DELIVERY

    ROOM

    LABOUR O.T.

    DOCTORS, NURSES

    & STAFF CHANGE

    ROOMS PATIENT LIFT

    NURSES STATION

    & DOCTORS ON

    DUTY

    DIRTYCORRIDOR

    O.P.D. block is provided as below in ground floor.

    MATERNITY COMPLEX

    Above emergency block Maternity block is provided so that a emergency

    labour case can be deal with minimum time loss.

    Planning is based on double corridor system in which sterile corridor is

    kept separate from non sterile corridor.Dirty corridor is provided with O.T. and delivery room which further lead to

    dumb waiter.

    MATERNITY BLOCK LAYOUT

  • 8/10/2019 nikhil ppt.pdf

    42/45

    350 BEDDED GENERAL HOSPITAL AT SUSHANT GOLF CITY, LUCKNOW

    Submitted By:Prachi Gupta

    Roll No. - 817

    IIA Part-IV-Group-B (2014-15)

    WAITING AREARECEPTIONSERVICE LIFT

    PRE

    OPERATIVE

    O.T. BLOCK POST

    OPERATIVE

    DOCTORS,

    NURSES & STAFF

    CHANGE ROOMSCONFERENCE

    ROOM

    SERVICES

    NURSES

    STATION &

    DOCTORS ON

    DUTY

    PATIENT LIFT

    DIRTYCORRIDOR

    O.T. BLOCK LAYOUT

    I.C.U BLOCK

    I.C.U. block is provided with o.t. complex.I.C.U is connected internally through O.T. block.

    A proper seperation of visitors are made, so that a visitors can meet

    patient in time limit only.A reception and gown change area is provided between patientsrelative

    waiting area and ICU.ICU is provided with nurses station, equipment store, clean utility, dirty

    utility, treatment room, ICU lab, ICU pharmacy, and a doctor on duty with

    his rest room.

    All patient beds are provided in glass cubicle , so that a clear visibility can

    be made.Distance between each bed is kept 3.0 mt. which is more than required.

    TYPICAL FLOOR

    WARD BLOCK

    Al above floors are provided with wards.

    RAMP

  • 8/10/2019 nikhil ppt.pdf

    43/45

    350 BEDDED GENERAL HOSPITAL AT SUSHANT GOLF CITY, LUCKNOW

    Submitted By:Prachi Gupta

    Roll No. - 817

    IIA Part-IV-Group-B (2014-15)

    FLOOR HEIGHTS

    There is one ramp is provided in hospital at centre place with slope 1:15 and width of

    3.0 mt.

    LIFT

    Separate lift are provided for doctors, ward patients, visitors, services and O.P.D.

    O.P.D LIFTS

    DOCTORS LIFTS

    SERVICE LIFTS

    INPATIENT

    WARD LIFT

    VISITORS

    LIFT

    STAIRCASE

    Staircase is provided with 2.0 mt. width.All staircase are provided at periphery and open outside at ground

    floor with 2.0 mt. wd. FHC, fire proof door.

    FHC is also provided with each staircase.

    BIBLIOGRAPHY

  • 8/10/2019 nikhil ppt.pdf

    44/45

    350 BEDDED GENERAL HOSPITAL AT SUSHANT GOLF CITY, LUCKNOW

    Submitted By:Prachi Gupta

    Roll No. - 817

    IIA Part-IV-Group-B (2014-15)

    BOOK REFERED:

    1. I.P.H.S2. N.B.C

    3. NEUFERT

    4. HOSPITALS, facilities planning and

    managementG. D. KUNDERS

    5. MODERN TRENDS in planning and

    designing of hospitalsS.K GUPTA.

  • 8/10/2019 nikhil ppt.pdf

    45/45

    350 BEDDED GENERAL HOSPITAL AT SUSHANT GOLF CITY, LUCKNOW

    Submitted By:Prachi Gupta

    Roll No. - 817

    IIA Part-IV-Group-B (2014-15)

    THE END

    THANK YOU