NIBE™ VVM 310 FLEXIBLE INDOOR MODULE INTELLIGENT HOT WATER • Complete all-in-one indoor module for heating and hot water. • For upgrading existing heating systems (perhaps a pool/ existing boiler can be combined) or new builds with requirements for high hot water performance. Swedish National Board of Housing, Building and Planning's Building Regulations adapted controls. • NIBE's air/water heat pumps together with VVM 310 make up a complete installation for heating and hot water. • A new generation control module with a colour display and several new functions. • NIBE Uplink TM • Simple connection and control of the external heat source (wood/oil/gas). Step controlled additional heat with immersion heater. • Integrated buffer tank for the heating system. • Hot water coil made of stainless steel. • Climate controlled automatic shunt valve that takes the outdoor temperature into consideration. • Self-regulating, speed controlled, charge respectively heating medium pump of A-class design. • Load monitor as standard. NIBE VVM 310 VVM 310 is a flexible indoor module and together with the NIBE's air/water outdoor modules creates a complete system to supply the building's heating and hot water requirements. VVM 310 can re- ceive energy from several different alternatives, for example from the F2030 and F2040 outdoor air heat pumps. It is also possible to supplement with energy from the existing boiler instead of using the internal immersion heater.

Transcript of NIBE™ VVM 310 FLEXIBLE INDOOR · PDF fileNIBE™ VVM 310 FLEXIBLE INDOOR MODULE...

Page 1: NIBE™ VVM 310 FLEXIBLE INDOOR · PDF fileNIBE™ VVM 310 FLEXIBLE INDOOR MODULE INTELLIGENT HOT WATER ... Designations in component locations according to standard IEC 81346-1 and

NIBE™ VVM 310FLEXIBLE INDOOR MODULE

INTELLIGENT HOT WATER

• Completeall-in-oneindoormoduleforheatingandhotwater.

• Forupgradingexistingheatingsystems(perhapsapool/existingboilercanbecombined)ornewbuildswithrequirementsforhighhotwaterperformance.SwedishNationalBoardofHousing,BuildingandPlanning'sBuildingRegulationsadaptedcontrols.

• NIBE'sair/waterheatpumpstogetherwithVVM310makeupacompleteinstallationforheatingandhotwater.

• Anewgenerationcontrolmodulewithacolourdisplayandseveralnewfunctions.

• NIBEUplinkTM

• Simpleconnectionandcontroloftheexternalheatsource(wood/oil/gas).Stepcontrolledadditionalheatwithimmersionheater.

• Integratedbuffertankfortheheatingsystem.

• Hotwatercoilmadeofstainlesssteel.

• Climatecontrolledautomaticshuntvalvethattakestheoutdoortemperatureintoconsideration.

• Self-regulating,speedcontrolled,chargerespectivelyheatingmediumpumpofA-classdesign.

• Loadmonitorasstandard.

NIBE VVM 310VVM 310 is a flexible indoor module and together with the NIBE's air/water outdoor modules creates a complete system to supply the building's heating and hot water requirements. VVM 310 can re-ceive energy from several different alternatives, for example from the F2030 and F2040 outdoor air heat pumps. It is also possible to supplement with energy from the existing boiler instead of using the internal immersion heater.

Page 2: NIBE™ VVM 310 FLEXIBLE INDOOR · PDF fileNIBE™ VVM 310 FLEXIBLE INDOOR MODULE INTELLIGENT HOT WATER ... Designations in component locations according to standard IEC 81346-1 and

-FL2

-CM1

-EB15

-FL1

-QM40-RM1

-RN10-EB101

XL2

XL1-HQ1

-QM1

-QM41

-FL10

-QM40

-EB101

2 NIBE VVM 310

System diagram

Basic docking with hot water and a heating system

HOW THE NIBE™ VVM 310 WORKS

VVM 310 is designed for connection and communication with NIBE's air/water heat pumps. NIBE's air/water heat pumps to-gether with VVM 310 make up a complete heating installation and cover the majority of the heating and hot water demand. If the outdoor temperature drops to a level below the stop tem-perature of the heat pump all heating then occurs with VVM 310.

Together with F2030, buildings with a heating requirement of 15 kW in climates with DUT hotter than -25°C can be satis-fied. With lesser heating requirements, use system F2040. NIBE's VPDIM dimensioning program is recommended for correct di-mensioning of the building's heating output requirements and climate. Hot water capacity is dependent on selected outdoor

module and whether addition is permitted. For example for sys-tem F2030-VVM310 tap volume 240 litres (40 °C) at 12 l/min applies when the tank is charged at only F2030.

When combined with an outdoor pool used in the summer sea-son, system F2030-VVM 310 does not usually need to be dimen-sioned up with regard to the size of the outdoor section. This is because the building's heating requirement is less in the summer time and F2030's output and efficiency increases with warmer outdoor temperatures. A system with VVM 310 and NIBE's air/water heat pumps gives full flexibility. Even if pool heating or other external heat sources were not included at installation, VVM 310 is prepared when that is required.

Page 3: NIBE™ VVM 310 FLEXIBLE INDOOR · PDF fileNIBE™ VVM 310 FLEXIBLE INDOOR MODULE INTELLIGENT HOT WATER ... Designations in component locations according to standard IEC 81346-1 and

NIBE VVM 310 3

R

0

+ 20-2

1

R

0

H M flo w4 9 (5 0 ) °CH o t w a te r 5 1 °C

+20

-2

1 R0

HM flo

w49 (

50) °C

Hot w

ater5

1 °C

R0

500

GOOD TO KNOW ABOUT NIBE™ VVM 310

LEK

LEK

LEK

Transport and storageVVM 310 must be transported and stored upright and dry.When being moved into a building, the VVM 310 may, however be carefullylaid on its back.

Quick and simple installation• No extra buffer tank for the heating system is required, be-

cause VVM 310 has full control of the heat pump and the heating system.

• New control with colour display and USB port.

• Installation help with step by step guide through the start-up process.

• Automatic setting of flow across heat pump and heating sys-tem.

• Factory installed components for best operational reliability and safe installation.

AssemblyPosition VVM 310 on a firm base that can bear its weight, prefer-ably on a concrete floor or foundation. Use the product's adjust-able feet to obtain a horizontal and stable set-up. The area where VVM 310 is located must be equipped with floor drainage.

Installation areaLeave a space of 500 mm in front of the product. All service on VVM 310 can be carried out from the front.

NOTE! Leave 10 - 25 mm free space between the indoor module and the wall behind for routing of cables and pipes.

Supplied components

The kit of supplied items is placed on top of the product.

Outdoor sensor Current sensorRoom sensor

Page 4: NIBE™ VVM 310 FLEXIBLE INDOOR · PDF fileNIBE™ VVM 310 FLEXIBLE INDOOR MODULE INTELLIGENT HOT WATER ... Designations in component locations according to standard IEC 81346-1 and

4 NIBE VVM 310

XL18 XL19

XL1 XL8

XL4XL2 XL9XL30 XL3

Pipe dimensions

GOOD TO KNOW ABOUT NIBE™ VVM 310

MaintenanceA minimum level of maintenance is required. Only safety valves require checking. All essential components can be accessed from the front. This facilitates service and maintenance.

InstallationVVM 310 is easy to install. All pipe connections are easily accessi-ble. This is especially useful for the replacement market.

EquipmentVVM 310 is equipped with a drain and reversing valve. In ad-dition, VVM 310 is equipped with climate controlled automat-ic bypasses with outdoor and supply temperature sensors, shunt valve, charge and circulation pump.

Expansion vesselDimensioned as 5 % of the maximum system volume (that is 250 litres plus maximum circulating volume in the heating cir-cuit). Equip the product with safety valve and expansion vessel, as these are not supplied with the product at delivery.

DesignVVM 310 is equipped with an intelligent control. This makes for easy operation at the same time as always enabling the indoor module to run as efficiently as possible. The control also manages the automatic bypass and circulation pumps. Current tempera-tures and set values can be shown on the display. The insulation is polyurethane, which provides excellent heat insulation. The outer casing is of white powder-coated steel plate.

Connection

XL1 Heating medium, supply G20 int.

XL2 Heating medium, return G20 int.

XL3 Cold water G20 int.

XL4 Hot water G20 int.

XL8 Connection, docking in heating medium G20 int.

XL9 Connection, docking out heating medium G20 int.

XL18 Connection, docking in high temp Ø 22 mm

XL19 Connection, docking out high temp Ø 22 mm

XL30 Connection, expansion vessel G20 int.

Page 5: NIBE™ VVM 310 FLEXIBLE INDOOR · PDF fileNIBE™ VVM 310 FLEXIBLE INDOOR MODULE INTELLIGENT HOT WATER ... Designations in component locations according to standard IEC 81346-1 and

NIBE VVM 310 5

GOOD TO KNOW ABOUT NIBE™ VVM 310

Dimensions

201780

560

600355

245

615

95

185

215

30-50

80135

190

80135

190300

Page 6: NIBE™ VVM 310 FLEXIBLE INDOOR · PDF fileNIBE™ VVM 310 FLEXIBLE INDOOR MODULE INTELLIGENT HOT WATER ... Designations in component locations according to standard IEC 81346-1 and

AA2

AA3-X4

Wilo

Wilo

VVM 310

UB1

UB2

XL4XL30XL2BT3

XL3 XL9

XL18 XL19

XL1 XL8

PF3

BT2

PF1

AA3

AA7

K1

QN10

GP1

QM20

BT63

BT7

EB1

BF1

PF1PF3

FD1

BT30

AA1

AA1-X3

AA1-SF1

AA1-X7

FA1

AA1-X1

QN11

AA4

SF1

AA4-XJ3

AA4-XJ4

UB1

UB2

BT6

BT54

GP12QM1QN35BP5

W130

6 NIBE VVM 310

Indoor module design

GOOD TO KNOW ABOUT NIBE™ VVM 310

Frontsida

701775

560

30-50

600

7575 757560 60

610

25

701775

560

30-50

600

7575 757560 60

610

25

PF3

Page 7: NIBE™ VVM 310 FLEXIBLE INDOOR · PDF fileNIBE™ VVM 310 FLEXIBLE INDOOR MODULE INTELLIGENT HOT WATER ... Designations in component locations according to standard IEC 81346-1 and

NIBE VVM 310 7

List of components

GOOD TO KNOW ABOUT NIBE™ VVM 310

Pipe connections

XL1 Connection, heating medium supply G20 int.

XL2 Connection, heating medium return line G20 int.

XL3 Connection, cold water G20 int.

XL4 Connection, hot water G20 int.

XL8 Connection, docking in heating medium G20 int.

XL9 Connection, docking out heating medium G20 int.

XL18 Connection, docking in high temp Ø22 mm

XL19 Connection, docking out high temp Ø22 mm

XL30 Connection, expansion vessel G20 int.

HVAC components

GP1 Circulation pump

GP12 Charge pump

QM1 Drain valve, heating medium

QN11 Mixing valve, addition

QM20 Venting, climate system

QN10 Reversing valve, climate system/water heating, supply line

QN35 Reversing valve, climate system/water heating, return line

Sensors etc.

BP5 Manometer, heating system

BT2 T emperature sensor, heating medium supply*

BT3 Temperature sensor, heating medium return*

BT6 Temperature sensor, hot water, charging

BT7 Temperature sensor, hot water, top

BT30 Thermostat, standby mode

BT54 Temperature sensor, external docking

BT63 Temperature sensor, heating medium supply after immersion heater

Electrical components

AA1 Immersion heater card

AA1-SF1 Dipswitch

AA1-X3 Terminal block, immersion heater

AA1-X7 Terminal block, immersion heater

AA2 Base card

AA3 Input circuit board

AA3-X4 Terminal block, current sensors

AA4 Display unit

AA4-XJ3 USB port

AA4-XJ4 Service socket

AA7 Extra relay circuit board

BF1* Energy meter**

EB1 Immersion heater

FA1 Miniature circuit-breaker

FD1 Temperature limiter

K1 Auxiliary relay, emergency mode.

SF1 Switch

W130 Network cable for NIBE Uplink™

Other information

PF1 Type plate

PF3 Serial number plate

UB1 Cable grommet

UB2 Cable grommet

* Not visible in the image**Only available as accessory EMK 310.Designations in component locations according to standard IEC 81346-1 and 81346-2

Page 8: NIBE™ VVM 310 FLEXIBLE INDOOR · PDF fileNIBE™ VVM 310 FLEXIBLE INDOOR MODULE INTELLIGENT HOT WATER ... Designations in component locations according to standard IEC 81346-1 and

8 NIBE VVM 310

INSTALLATION

EP30 Solar kit

AA5 Accessory card

BT53 Temperature sensor, solar panel

CM5 Expansion vessel

EP8 Solar panel

GP30 Pump station SPS 10, SPS20

GP30 Pump station SPS 10, SPS 20

FL4 Safety valve, solar

GP4 Pump, solar

QM43 Shut-off valve

QM44 Shut-off valve

QM45 Shut-off valve

RM3 Non-return valve

RM4 Non-return valve

Other information

CM1 Expansion vessel closed, heating medium

EB1 Immersion heater

FL1 Safety valve, hot water

FL2 Safety valve, heating medium

QM40 Shut-off valve

RM1 Non-return valve

Explanation

CL11 Pool kit

AA5 Accessory card

BT51 Temperature sensor, pool

EP5 Exchanger, pool

GP9 Pool, pump

HQ4 Particle filter

QN19 Reversing valve, pool

EB15 VVM 310

XL1 Connection, heating medium, supply 1

XL2 Connection, heating medium, return 1

XL3 Connection, cold water

XL4 Connection, hot water

XL8 Connection, docking, in heating medium

XL9 Connection, docking, out heating medium

XL13 Connection, solar system, supply

XL14 Connection, solar system, return

XL 39 Connection, accessory, out

EB101 Heat pump

FL10 Safety valve

HQ1 Particle filter

RN10 Trim valve

QM1 Draining valve

QM40 Shut-off valve

QM41 Shut-off valve

EM1 Wood burning stove with back boiler

AA5 Accessory card

BT52 Temperature sensor, boiler

EM1 Wood burning stove with back boiler

GP15 Charge pump, external heat source

EP21 Climate system 2

AA5 Accessory card

BT2 Temperature sensor, heating medium, supply

BT3 Temperature sensor, heating medium, return

GP20 Circulation pump, heating medium, lower shunt

QN11 Mixing valve, addition

Page 9: NIBE™ VVM 310 FLEXIBLE INDOOR · PDF fileNIBE™ VVM 310 FLEXIBLE INDOOR MODULE INTELLIGENT HOT WATER ... Designations in component locations according to standard IEC 81346-1 and

-FL2

-CM1

-EB15

-XL8 -XL9

NIBE VVM 310 9

-FL2

-CM1

-EB15

-XL8

-XL9

-RN10-EB101

XL2

XL1-HQ1

-QM1

-QM41

-FL10

-QM40

-EB101

Connection as electric boiler

Connect the pipe for docking in from the heat pump (XL8) to the pipe out to the heat pump (XL9).

Installation alternative

Compatible NIBE air/water heat pumpsCompatible NIBE air/water heat pumps must be equipped with a control card with display that has the software version given in the following list as a minimum. The control card version is displayed in the heat pump's display upon start-up.

Connecting to heat pumpAll outdoor pipes must be thermally insulated with at least 20 mm thick pipe insulation. VVM 310 is not equipped with shut off valves; these must be installed outside the indoor module to facil-itate any future servicing. The charge circuit is supplied with trim valve for basic setting of the charge flow.

Product Software version

F2025/F2300 55

F2030/F2040 all versions

VVM 310 can be connected to extra water heater. See the last page for the list of the accessories that can be used with VVM 310.

Page 10: NIBE™ VVM 310 FLEXIBLE INDOOR · PDF fileNIBE™ VVM 310 FLEXIBLE INDOOR MODULE INTELLIGENT HOT WATER ... Designations in component locations according to standard IEC 81346-1 and

-FL2

-CM1

-EB15

-XL18

-XL19

-BT52-EM1-AA25

-EM1

-GP15

-FL2

-CM1

-EB15

-XL1

-XL2

-GP20

-BT3

-BT2

-QN25

-EP21-AA25

-FL2

-CM1

-EB15

-XL1

-XL2

-FL2

-XL4

-XL3

-CM1

-EB15

-FL1

-QM40-RM1

INSTALLATION

10 NIBE VVM 310

Connecting cold and hot water The mixing valve must be installed if the factory setting is changed so that the temperature can exceed 60 °C. If the fac-tory setting is changed, national regulations must be observed. The setting is made in menu 5.1.1.

Connecting the climate system

When connecting to a system with thermostats on all radiators/underfloor heating coils, a relief valve must be fitted, or a thermo-stat must be removed to ensure sufficient flow.

Two or more climate systems

When more than one climate system is to be heated, the follow-ing connection can be used. For this connection accessory ECS 40/ECS 41 is required.

Connection of external heat source

For connection to gas/ electric/ oil boiler the DEH 310 accessory is required.

Page 11: NIBE™ VVM 310 FLEXIBLE INDOOR · PDF fileNIBE™ VVM 310 FLEXIBLE INDOOR MODULE INTELLIGENT HOT WATER ... Designations in component locations according to standard IEC 81346-1 and

-FL2

-CM1

-EB15

-RN10-EB101

XL2

XL1-HQ1

-QM1

-QM41

-FL10

-QM40

-EB101

-GP9 -BT51 -HQ4

-EP5

-AA25

-CL11

-CL11-QN19

-CL11-GP12

T PT

-FL2-CM1

-XL18

-XL19

-EB15-EP30

-BT53

-EP8

-EB101

-FL10

-AA5-GP30

-RM4

-GP4 -EP5

-RM3

-GP4

-CM5

-FL4

-OM44

-OM43-OM45

XL1

XL2

-RN10 -QM40

-HQ1 -QM41

-QM1

-FL2

-CM1

-EB15

-XL8

-XL9

-RN10-EB101

XL2

XL1-HQ1

-QM1

-QM41

-FL10

-QM40

-EB101

BF1

-FL2

-CM1

-EB15

-XL8

-XL9

-RN10-EB101

XL2

XL1-HQ1

-QM1

-QM41

-FL10

-QM40

-EB101

EB1

-FL2-CM1

-EB15

-FL1

-QM40-RM1

-GP9

XL3

XL4

NIBE VVM 310 11

INSTALLATION

SunThe SCA 35 accessory is required for connection to solar instal-lation.

PoolCharging of the pool is controlled by the pool sensor. In the case of low pool temperatures, the reversing valve reverses direction and opens towards the pool exchanger. Accessory POOL 310 is required for this connection.

Connecting ELK

For connection of external electrical addition, in one step, in event of a stoppage because of cold outdoor air.

Connecting EMK 310 Connection of energy measurement kit EMK 310 (BF1) to VVM 310.

Connecting hot water circulationTo reduce the risk of bacterial growth in systems with hot water circulation, the temperature of the circulating water should not fall below 50°C. There should not be any non-circulatory hot wa-ter pipes. Adjust the hot water system so that the temperature does not fall below 50 °C at the ends of the system.

Page 12: NIBE™ VVM 310 FLEXIBLE INDOOR · PDF fileNIBE™ VVM 310 FLEXIBLE INDOOR MODULE INTELLIGENT HOT WATER ... Designations in component locations according to standard IEC 81346-1 and

LE

K

INSTALLATION

12 NIBE VVM 310

USB service outlet

VVM 310 is equipped with a USB socket in the display unit. This USB socket can be used to connect a USB memory stick to up-date the software, save logged information and handle the set-tings in VVM 310.

SMS 40

VVM 310 can be controlled and monitored externally with ac-cessory SMS 40. SMS 40 consists of a communications module, a GSM modem with an antenna and a separate power supply unit with jack for plugging into a wall socket. The antenna can be placed outside the enclosure. SMS 40 enables operation to be controlled and monitored, via a GSM module, using a mo-bile phone via SMS messages. For the GSM function to work, the communications module must be equipped with a valid GSM subscription. This may, for example, be a pay as you go card or a special telematics subscription. For further presentation, visit www.nibe.eu

NIBE UplinkTM

Using the Internet and NIBE UplinkTM you can get a quick over-view and the present status of the installation the heating in your home. You get a good overall view where you can follow and control the heating and hot water comfort. If your system is af-fected by an operational disturbance, you receive an alert via e-mail that allows you to react quickly. NIBE UplinkTM also gives you the opportunity to easily control the comfort in the home, no matter where you are.

Range of services

Via NIBE UplinkTM you have access to different levels of service. A basic level that is free and a premium level where you can select different extended service functions for a fixed annual subscrip-tion fee (the subscription fee varies depending on the selected functions).

Installation and associated equipment requirements

The following is required in order for NIBE UplinkTM to work with the installation:

• Network cable Cat.5e UTP (straight, male-male), wired net-work communication.

• Internet connection (broadband).

• The web browser that supports JavaScript. If Internet Explor-er is used, it must be version 7 or higher. See the help file in the web browser for information about how to activate JavaScript.

Electrical connectionsGeneral

All electrical equipment, except the outdoor sensors, room sen-sors and the current sensors are already connected at the factory.

• Disconnect the indoor module before insulation testing the house wiring.

• When the building is equipped with an earth-fault breaker, VVM 310 should be equipped with a separate one.

• The electrical circuit diagram for the indoor module is at the end of this Installer manual.

• Communication and sensor cables to external connections must not be laid close to high current cables.

• The minimum area of communication and sensor cables to ex-ternal connections must be 0.5 mm² up to 50m, for example EKKX, LiYY or equivalent.

• When cable routing in VVM 310 cable grommets UB1 and UB2 must be used. In UB1 and UB2 the cables are inserted through the indoor module from the back to the front.

Miniature circuit-breaker

The indoor module and a large proportion of its internal com-ponents are internally fused by a miniature circuit breaker (FA1).

Temperature limiter

The temperature limiter (FD1) cuts the current supply to the elec-trical addition if the temperature rises to between 90 and 100 °C and is manually reset.

SettingsElectrical addition - maximum output

The immersion heater can be set up to a maximum of 12 kW. Delivery setting is 8 kW. The immersion heater output is divided into 9 steps, according to the table in the Installer manual. Set-ting maximum output in the electrical addition is done in menu 5.1.12.

Standby mode

When the indoor module switch (SF1) is set to emergency mode only the most necessary functions are activated.

• The hot water capacity is reduced.

• The load monitor is not connected.

• Fixed temperature in the supply line.

Page 13: NIBE™ VVM 310 FLEXIBLE INDOOR · PDF fileNIBE™ VVM 310 FLEXIBLE INDOOR MODULE INTELLIGENT HOT WATER ... Designations in component locations according to standard IEC 81346-1 and

6

4

8

10

12

14

16

18

20

50 100 150 200 250 300 350 400 450

Tappflöde (liter/minut)

Volym varmvatten (liter)

Varmvattenkapacitet VVM310

Ekonomi

Ekonomi

Normal

Normal

Lyx

Lyx

The diagram above displays what hot water capacity VVM 310 can supply at the different selectable comfort modes.

The difference between the selectable modes is the temperature of the hot tap water. Higher temperature means hot water lasts longer.

economy: This position gives less hot water, but is more eco-nomical. This mode can be used in smaller households with a small hot water requirement.

Water capacityHot water capacity NIBE VVM 310 with NIBE F2040/F2300

Tap flow (l/min)

Economy Normal Lux

Tap volume (l) hot water

normal: Normal mode gives a larger amount of hot water and is suitable for most households.

luxury: Lux mode gives the greatest possible amount of hot wa-ter. In this mode, the immersion heater, as well as the compressor, is used to heat hot water, which may increase operating costs.

F2040 requires additional heat (internal or external) to reach Lux-ury.

In most cases, F2300 reaches all three settings (including Lux), with just a compressor.

Pump capacity diagramAvailable pressure, circulation pump for heating systems, GP1 Available pressure, charge circulation pump, GP12

Available pressure (Pa)

Water flow (l/s)Water flow (l/s)

INSTALLATION

0

10

20

30

40

50

60

0 200 400 600 800 1000 1200 1400 1600 1800 2000Flöde (liter/timme)

Tillgängligt tryck [kPa]

Tillgängligt tryck cirkulationspump, GP1

0

10

20

30

40

50

60

0 200 400 600 800 1000 1200 1400 1600 1800 2000

Tillgängligt tryck cirkulationspump, GP12

Flöde (liter/timme)

Tillgängligt tryck [kPa]

Available pressure (Pa)

NIBE VVM 310 13

Page 14: NIBE™ VVM 310 FLEXIBLE INDOOR · PDF fileNIBE™ VVM 310 FLEXIBLE INDOOR MODULE INTELLIGENT HOT WATER ... Designations in component locations according to standard IEC 81346-1 and

14 NIBE VVM 310

THE DISPLAY

Display unit

Display, A

Instructions, settings and operational information are shown on the display. The easy-to-read display and menu system facilitates navigation between the different menus and options to set the comfort or obtain the information you require.

Status lamp, B

The status lamp indicates the status of the heat pump. It:

• lightsgreenduringnormaloperation.

• lightsyellowinemergencymode.

• lightsredintheeventofadeployedalarm.

OK button, C

The OK button is used to:

• confirmselectionsofsubmenus/options/setvalues/pageinthestartguide.

Back button, D

The back button is used to:

• gobacktothepreviousmenu.

• changeasettingthathasnotbeenconfirmed.

B

A

C

D

E

FVVM 310

Status lamp

Display

OK button

Back button

Control knob

Switch

Control knob, E

The control knob can be turned to the right or left. You can:

• scrollinmenusandbetweenoptions.

• increaseanddecreasethevalues.

• changepageinmultiplepageinstructions(forexamplehelptextandserviceinfo).

Switch, F

The switch assumes three positions:

• On( )

• Standby( )

• Emergencymode( )

A large, easy to read multicoulour display gives everyone the chance to maximize the energy saving potential of this exciting green technology!

Page 15: NIBE™ VVM 310 FLEXIBLE INDOOR · PDF fileNIBE™ VVM 310 FLEXIBLE INDOOR MODULE INTELLIGENT HOT WATER ... Designations in component locations according to standard IEC 81346-1 and

HEAT PUMP

NIBE UplinkTM

(if contact with NIBE

UplinkTM is available)

INDOOR CLIMATE HOT WATER

NIBE VVM 310 15

THE DISPLAY

Menu system When the door to the heat pump is opened, the menu system’s four main menus are shown in the display as well as certain ba-sic information.

Menu 1 – Indoor climate

Setting and scheduling the indoor climate.

Menu 2 – Hot water

Setting and scheduling hot water production.

This menu only appears if a water heater is docked to the heat pump.

Menu 3 - Info

Display of temperature and other operating information and ac-cess to the alarm log.

Menu 4 – Heat pump

Setting time, date, language, display, operating mode etc.

Menu 5 - Service

Advanced settings. These settings are not available to the user. The menu is visible by pressing the Back button for 7 seconds.

Start guideThe first time the heat pump is started a start guide is started. The start guide instructions state what needs to carried out at the first start together with a run through of the heat pump’s basic settings.

The start guide ensures that the start-up is carried out correctly and cannot be bypassed. The start guide can be started later in menu 5.7.

Indoor temperature - (if a room sensor is connected)Outdoor temp. Hot water temp.

Extra hot water (if activated)

Estimated amount of hot water

If the start guide is left on this page it closes automatically in 60 min

Page 16: NIBE™ VVM 310 FLEXIBLE INDOOR · PDF fileNIBE™ VVM 310 FLEXIBLE INDOOR MODULE INTELLIGENT HOT WATER ... Designations in component locations according to standard IEC 81346-1 and

16 NIBE VVM 310

1) Applies to outdoor air heat pump at 7/45 °C (outdoor temperature / Supply temperature)

IP 21TECHNICAL SPECIFICATIONS

3x400V

Maxim heat pump output NIBE F2025 with program version 55 or later 1) kW 10

Maxim heat pump output NIBE F2026 with program version 55 or later 1) kW 10

Maximum heat pump output NIBE F2030 1) kW 9

Maximum heat pump output NIBE F2040 1) kW 12

Maximum additional power (internal) kW 12

Electrical data

Rated voltage 400V 3NAC 50 Hz

Max operating current A 19,4

Fuse A 20

Power, HM pump W 10 - 110

Output charge pump W 10 - 110

IP class IP 21

Heating medium circuit

Energy class circ-pump low energy

Energy class charge pump low energy

Max system pressure heating medium MPa 0.3 (3 bar)

Min flow l/t 500

Max HM temp °C 70

Pipe connections

Heating medium, CU pipe G20 int.

Hot water connection G20 int.

Cold water connection G20 int.

Heat pump connections G20 int.

Connection for expansion vessel G20 int.

Other information

Indoor module

Volume coil litre 17

Volume, total indoor module litre 270

Volume buffer vessel litre 50

Cut-off pressure, coil MPa 1.0 (10 bar)

Max permitted pressure in indoor module MPa 0.3 (3 bar)

Capacity hot water heating According to EN 255-3

Tap volume 40°C at Eco comfort litre See diagram page 13.

Tap volume 40°C at Normal comfort litre See diagram page 13.

Tap volume 40°C at Luxury comfort litre See diagram page 13.

Dimensions and weight

Width mm 600

Depth mm 615

Height (without base) mm 1800

Height (with base) mm 1830 – 1850

Required ceiling height mm 1910

Weight (excl. packaging and without water) kg 140

Page 17: NIBE™ VVM 310 FLEXIBLE INDOOR · PDF fileNIBE™ VVM 310 FLEXIBLE INDOOR MODULE INTELLIGENT HOT WATER ... Designations in component locations according to standard IEC 81346-1 and

LEK

LEK

LEK

LEK

LEK

LEK

LEK

LEK

LEK

LE

K

LEK

LEK

LEK

LEK

LEK

LEK

LEK

LEK

LEK

LEK

NIBE VVM 310 17

ACCESSORIES

Active cooling ACS 310

Part no. 067 248

Energy measurement kit EMK 310

This accessory is used to measure the amount of en-ergy VVM 310 produces and supplies for hot water and

heating in the building.

Part no. 067 246

External electrical addi-tion ELK

This accessory requires ac-cessory DEH 310

(step controlled addition-al heat).

ELK 15

Part no. 069 022

Extra shunt group ECS 40/ECS 41

This accessory is used when VVM 310 is installed in

houses with two or more different climate systems that require different sup-

ply temperatures.

ECS 40 (max 80 m2)

Part no. 067 287 ECS 41 (min 80 m2)

Part no. 067 288

Base extension EF 45

Part no. 067 152

Auxiliary relay HR 10

Part no 089 423

Control unit for external heat source

DEH 310 (oil/electric-ity/gas)

Part no. 067 249

Pool heating POOL 310

POOL 310 is an accessory that enables pool heating

with VVM 310. Part no. 067 247

Communication module SMS 40

SMS 40 enables VVM 310 to be controlled and moni-tored via SMS messages. The mobile application ”NIBE Mobile App” can

be used with a mobile tel-ephone with the Android

operating system.

Part no. 067 073

Communication module MODBUS 40

MODBUS 40 enables VVM 310 to be controlled and

monitored using a DUC in buildings. Communication takes place using a MOD-

BUS-RTU.

Part no. 067 144

Room unit RMU 40

RMU 40 means that con-trol and monitoring of the indoor module can be car-ried out in a different part of the accommodation to

where VVM 310 is located.

Part no. 067 064

Top cabinet

2050mm

Part no. 089 756

2150 mm

Part no. 089 757

2200-2450 mm

Part no. 089 758

Heat pump F2040

8 kW Part no. 064 109

12 kW Part no. 064 092

16 kW Part no. 064 108

Heat pump F2030

7 kW Part no. 064 099

9 kW Part no. 064 070

SCA 35 (solar)

Possible connection and control of solar heating.

Part no. 067 245

For complete solar pack-age, see www.nibe.eu

Page 18: NIBE™ VVM 310 FLEXIBLE INDOOR · PDF fileNIBE™ VVM 310 FLEXIBLE INDOOR MODULE INTELLIGENT HOT WATER ... Designations in component locations according to standard IEC 81346-1 and

18 NIBE VVM 310

This brochure is a publication from NIBE. All product illustrations, facts and specifications are based on current information at the time of the publication’s approval. NIBE makes reservations for any factual or printing errors in this brochure. Photos: www.benfoto.se. ©NIBE 2014.

NIBE is ISO-certified: SS-EN ISO 9001:2000SS-EN ISO 14001:2004

6395

84 T

echn

ical

PBD

GB

NIB

E V

VM

310

143

3-1

NIBE Energy Systems ABBox 14285 21 MarkarydSWEDENTel. +46 433 - 73 000www.nibe.eu