Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans...

83
Nexans Cabling Solutions, Jan 2004

Transcript of Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans...

Page 1: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 1

Page 2: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 2

Facts about Nexans

Technics

Cabling evolution

Parameters

Cat 6 versus Cat 5

Standardization – What is Deembedding?

Nexans Solutions Class D/E/F, Essential

Installation Issues/Installation practice

FO theory/FO practice

Tendencies in Structured Cabling / FTTW

Agenda

Page 3: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 3

Why Universal Cabling ?

Cabling Evolution

Page 4: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 4

Telephone

Informatics

Unstructured

Structured

Universal Cabling System

Pre-engineered Cabling System

Cabling Evolution

Page 5: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 5

Telephony

PABX

Basic Star Structure: still applicable today

Voice Grade Cable: not installed any more

Cabling Evolution

Page 6: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 6

Data networking (80 - 90) LAN introduction New cable media

HOST

Cabling Evolution

10BASE5

Token Ring

FDDI

SAS

DAS

Page 7: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 7

Unstructured

Each system had a different kind of transmission medium (UTP, STP, coax, twinax, ...)

The Solution installed is not compatible with other Solutions

Costly moves and changes

No overview

Spaghetti cabling

Cabling Evolution

Page 8: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 8

Universal Cabling

Two media: copper twisted pair and optical fiber

Voice, data, video, control signals

Patching Facilities

Universal (Generic): application independent

Cabling Evolution

Page 9: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 9

I want to communicate

with you

No problem, I am conform

with the OSI model

Influence of applications on system performance requirements

Page 10: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 10

TCP/IP = OSI-like Model

Layer 1: physical layer

Layer 3: Network Layer

Layer 2: Data Link Layer

Layer 4: Transport Layer

IP Header

Data Layer 3: Network Layer

Ethernet Header

Data Layer 2: Data Link Layer

Layer 4: Transport Layer

Layer 5-7: Higher OSI Layers

Layer 5-7: Higher OSI Layers

TCP header

Ethernet Header

Data

IP Header

Data

TCP header

Page 11: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 11

Network Layer

IP Head

er

Data Layer 3: Network Layer

TCP header

Layer 4: Transport Layer

Layer 5-7: Higher OSI Layers

IP Head

er

DataLayer 3: Network Layer

TCP header

Layer 4: Transport Layer

Layer 5-7: Higher OSI Layers

The Network Layer 3 addresses the interconnection of networks by routing packets from one network to another.

To route packets across different networks we need a router

Page 12: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 12

IP address (32 bits)

4 Bytes

IP address

129 . 60 . 10 . 70

Network Layer

Primary function of IP : to provide an reliable, best effort, connectionless datagram delivery.

Page 13: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 13

Data Link Layer

IP Header

Data Layer 3: Network Layer

Ethernet Header

Data Layer 2: Data Link Layer

TCP heade

r

Layer 4: Transport Layer

Layer 5-7: Higher OSI Layers

IP Header DataLayer 3: Network Layer

DataLayer 2: Data Link Layer

TCP header

Layer 4: Transport Layer

Layer 5-7: Higher OSI Layers

Ethernet Header

This layer contains the MAC address (Medium access control) - Bridging or switching

The data link layer must contain Length of the frames

a means of addressing

access control to the medium

error detection (and correction)

Page 14: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 14

3 Bytes 3 Bytes

MAC address

0 0 AA 00 32 2A 6B

Supplier identification

MAC address (48 bits)

Influence of applications on system performance requirements

Page 15: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 15

Layer 1

Layer 1: physical layer, the Cabling System

IP Header Data Layer 3: Network

Layer

Ethernet Header

Data Layer 2: Data Link Layer

Layer 4: Transport Layer

Layer 5-7: Higher OSI Layers

TCP header

Layer 3: Network Layer

Layer 2: Data Link Layer

Layer 4: Transport Layer

Layer 5-7: Higher OSI Layers

Ethernet Header

Data

IP Header Data

TCP header

Page 16: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 16

OSI Model

Layer 1: physical layer

This Layer addresses the physical characteristics of the network Types of cables used

Types of connectors used

Required Performance levels of the links and channels

Max. length of the cables

Defines the representation of bits (zero’s and ones) on the cable

frequency, voltage, encoding techniques

The higher layers give a meaning to these bit values

Layer 1: physical layer, the Cabling system

Page 17: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 17

Ethernet 10 Mbps 10 MHz Manchester Encoding Technique

The Network Interface Cards (NIC) translate the bits into voltage levels (Frequencies). The encoding technique compresses the bit stream so that high bit rate application can be transported over lower bandwidth links.

Because of the fact that the transmission speed is depending on the encoding technique, we do not use the term Mbps to compare cables to each other, but we use MHz which is the parameter expressing the bandwidth of the cable.

The physical Layer 1 is thus completely determined by the upper laying layers

OSI Model: From bits to frequencies

Layer 1: physical layer

Page 18: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 18

Ethernet: The physical layer

IEEE802.3 10BASE-T

Twisted pair RJ45 100 m Manchester encoding 3V Class C link/channel performance required

Influence of applications on system performance requirements

Page 19: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 19

Gigabit Ethernet: The physical layer

IEEE802.z 1000BASE-T

Twisted pair RJ45 100 m PAM 5 encoding 3V Class D’99 link/channel performance required Class D’01 preferred

Influence of applications on system performance requirements

Page 20: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 20

Class C / Cat 3

Category 4

Category 5 / Class D

Class E / Category 6

Class F / Category 7

16 MHz 20 MHz 100 MHz 200 MHz 600 MHz

Class D / Category 5 (+amendment)

(Category 4)

Standardisation : Universal Cabling

Page 21: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 21

Facts about Nexans

Technics

Cabling evolution

Parameters

Cat 6 versus Cat 5

Standardization – What is Deembedding?

Nexans Solutions Class D/E/F, Essential

Installation Issues/Installation practice

FO theory/FO practice

Tendencies in Structured Cabling / FTTW

Agenda

Page 22: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 22

Megabits or MegaHertz ? ? ?

Attenuation

Near-End Crosstalk

Attenuation to Crosstalk Ratio

PowerSum Next, PowerSum ACR

ELFEXT, PowerSum ELFEXT

Delay Skew

Return Loss

Coupling Attenuation

Electromagnetic Interference

Technical Knowledge

Page 23: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 23

2000 rpm = ? km/h

2000 rpm = ? km/h

Which one is faster ?

Megabits or MegaHertz ?

Page 24: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 24

CODING IS AN APPLICATION DEPENDENT NECESSITY !!!APPLICATION Mbps Bandwidth Encoding Technique

Ethernet 10 Mbps 10 MHz (Manchester)

Token Ring 4 & 16 Mbps 16 MHz (Manchester)

Fast Ethernet 100 Mbps 62,5 MHz (NRZI + 4B5B)

TP-PMD 31,25 MHz (MLT-3 + 4B5B)

ATM 155 Mbps 78 MHz (NRZ)

1000BASE-T 1000 Mbps 125 MHz (PAM-5)

100 Mbps x conversion factor = ??? MHz

OSI Model: From bits to frequencies: Encoding Techniques

1000BASE –TXX 1000 Mbps 250 MHz (PAM-5)

ATM 1000 1000Mbps 250 Mhz

Page 25: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

‘80

Ethernet10 Mb/s

‘85

TokenRing

16 Mb/s

‘93

FDDI100 Mb/s

‘94

FastEthernet100Mb/s

‘95

ATM155 Mb/s

‘98

Gigabit

Ethernet

1000 Mb/s

Capability ofCabling

Infrastructure

Requestof

Bandwidth

AN EFFICIENT CABLING SYSTEM

HAS TO ANTICIPATE

Cabling Evolution

Page 26: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 26

Digital Signal Encoding

0 1 0 0 1 1 0 1 0 0

NRZ-I

Man

Page 27: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 27

Influence of Noise

Signal/Noise Ratio (SNR) is more important with higher levels of coding

Page 28: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 28

We use km/h to express the speed of a car Use MegaHertz to express transmission speed !!!

Megabits or MegaHertz ?

Page 29: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 29

Megabits or MegaHertz ? ? ?

Attenuation

Near-End Crosstalk

Attenuation to Crosstalk Ratio

PowerSum Next, PowerSum ACR

ELFEXT, PowerSum ELFEXT

Delay Skew

Return Loss

Coupling Attenuation

Electromagnetic Interference

Technical Knowledge

Page 30: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 30

Attenuation (Insertion loss)

I am talking to you ! Can you hear me ?

Attenuation

Page 31: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 31

The amount of signal loss in the transmission link (expressed in dB)

dB LossdB Loss

SignalSource

SignalReceiver

Attenuation

Attenuation

Page 32: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 32

Megabits or MegaHertz ? ? ?

Attenuation

Near-End Crosstalk

Attenuation to Crosstalk Ratio

PowerSum Next, PowerSum ACR

ELFEXT, PowerSum ELFEXT

Delay Skew

Return Loss

Coupling Attenuation

Electromagnetic Interference

Technical Knowledge

Page 33: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 33

Near End Crosstalk (NEXT)

Eric Bob

Chris Dave

Near End Crosstalk

= NEXT is a measure of signal coupling from one pair to another pair.

Page 34: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 34

Megabits or MegaHertz ? ? ?

Attenuation

Near-End Crosstalk

Attenuation to Crosstalk Ratio

PowerSum Next, PowerSum ACR

ELFEXT, PowerSum ELFEXT

Delay Skew

Return Loss

Coupling Attenuation

Electromagnetic Interference

Technical Knowledge

Page 35: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 35

ACR (dB) = NEXT (worst case) - attenuation(worst case)

Attenuation to crosstalk ratio (ACR)

60 dB

50 dB

40 dB

30 dB

20 dB

10 dB

10 10020 8030 40 50 60 70 90 Frequency(MHz)

ACR

Minimal LANmark5/ Cat.5e350 link performance

ISO/IEC IS 11801 specification

ISO/IECNexans Cabling Solutio

ns

70 dB

8.7 dB

16 dB

Attenuation to Crosstalk Ratio

Page 36: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 36

Rule : For high speed

applications ACR of a link

should be better than 13 dB

at 100 MHz

Fast Ethernet100 Mbps

Gigabit Ethernet1000 Mbps

ATM155 Mbps

Attenuation to Crosstalk Ratio

Page 37: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 37

Megabits or MegaHertz ? ? ?

Attenuation

Near-End Crosstalk

Attenuation to Crosstalk Ratio

PowerSum Next, PowerSum ACR

ELFEXT, PowerSum ELFEXT

Delay Skew

Return Loss

Coupling Attenuation

Electromagnetic Interference

Technical Knowledge

Page 38: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 38

Focus on phenomena that will occur :

during a simultaneous parallel transmission of data

in both directions

on all four pairs in the cable

Simplex bi-directional transmission

Full duplex bi-directional transmission on 4 pairs

Technical Knowledge

Page 39: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 39

Simplex bi-directional transmission (over 2 pairs) e.g. Ethernet, Token Ring

attenuation NEXT ACR

Full duplex bi-directional transmission (over 4 pairs) e.g. Gigabit Ethernet:

PowerSum specs (PSNEXT, PSACR) ELFEXT, PSELFEXT Delay skew Return loss Coupling attenuation

Technical Knowledge

Page 40: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 40

1000 Mbps Full Duplex over 4 pairs ? 250 Mbps on each pair in both directions

1000 Mbps simultaneously in both directions

Technical Knowledge

Page 41: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 41

Near End Crosstalk (NEXT)

= NEXT is a measure of signal coupling from one pair to another pair.

Near End Crosstalk

Page 42: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 42

= NEXT coupling from 3 adjacent pairs transmitting simultaneously

PowerSum NEXT

Alan

Eric

Geoff

Bob

Andres

Franco

Chris DavePowerSum

NEXT

PowerSum NEXT

Page 43: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.
Page 44: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 44

Powersum NEXT

RX

TX-

+

Need 4 of these

PowerSum NEXT

In Gigabit Ethernet : PowerSum NEXT will be cancelled out !

Page 45: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 45

PowerSum ACR

Attenuation to Crosstalk Ratio

ACR = NEXT - attenuation

PowerSum ACR

PSACR = PSNEXT - attenuation

ACR/PSACR is the signal to noise ratio considering NEXT/PSNEXT as the only noise sources.

Cabling Solutions Europe,May 2000 - 43

ACR (dB) = NEXT Loss (worst case) - (worst case)

60 dB

50 dB

40 dB

30 dB

20 dB

10 dB

10 10020 8030 40 50 60 70 90 Frequency(MHz)

ACR

Minimal Cat.5e350 link performance

ISO/IEC IS 11801 specification

ISO/IECAlcatelCablingSolutions

70 dB

Attenuation to crosstalk ratio (ACR)

8.7 dB

16 dB

Attenuation to Crosstalk Ratio

Page 46: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 46

60 dB

50 dB

40 dB

30 dB

20 dB

10 dB

20 20040 16060 80 100 120 140 180 Frequency(MHz)

70 dB

PS ACR

Attenuation to Crosstalk Ratio

LANmark 6 channel - 2 connectors

LANmark 6 channel - 4 connectors

ISO/IEC JTC 1/SC 25/WG 3 N568 specification

11.5 dB7.4 dB0.1 dB

Page 47: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 47

Defined in the ISO and TIA standards

Worst Case configuration

Allows patching between patch panels

High flexibility for modern office environments (zone wiring)

Nexans offers 4x RJ45 connections

Nexans’ Class E channel outperformes the standards

The 4 Connector Channel Model

Page 48: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 48

4 connector channel ACR

ACR

-40

-20

0

20

40

60

80

100

120

0 100 200 300 400 500 600

Frequency [MHz]

AC

R [

dB

]

N1-2D1 N1-2D2 N1-3D1 N1-3D3 N1-4D1 N1-4D4 N2-3D2

N2-3D3 N2-4D2 N2-4D4 N3-4D3 N3-4D4 ACR Grenzkurve

Page 49: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 49

Megabits or MegaHertz ? ? ?

Attenuation

Near-End Crosstalk

Attenuation to Crosstalk Ratio

PowerSum Next, PowerSum ACR

ELFEXT, PowerSum ELFEXT

Delay Skew

Return Loss

Coupling Attenuation

Electromagnetic Interference

Technical Knowledge

Page 50: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 50

= is signal coupling from one pair to another pair,

measured at the far end

FEXT

Far End Crosstalk (FEXT)

Far End Crosstalk

Eric Dave

Geoff Andres

Page 51: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 51

= FEXT coupling from 3 adjacent pairs transmitting simultaneously

PowerSum FEXT

PowerSum FEXT

Eric Andres

Alan

Chris

Geoff

Bob

Dave

Franco

PowerSum FEXT

Page 52: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.
Page 53: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 53

PowerSum ELFEXT

PowerSum ELFEXT

Page 54: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 54

Equal Level FEXT

ELFEXT = FEXT - attenuation

PowerSum ELFEXT

PS ELFEXT = PSFEXT - attenuation

= similar to ACR/PSACR, which is the signal to noise ratio considering NEXT/PSNEXT as the only noise, while ELFEXT/PSELFEXT expresses the signal to noise ratio considering FEXT/PSFEXT only.

PowerSum ELFEXT

Page 55: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 55

Megabits or MegaHertz ? ? ?

Attenuation

Near-End Crosstalk

Attenuation to Crosstalk Ratio

PowerSum Next, PowerSum ACR

ELFEXT, PowerSum ELFEXT

Delay Skew

Return Loss

Coupling Attenuation

Electromagnetic Interference

Technical Knowledge

Page 56: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 56

Delay Skew

Delay Skew

I am to youtalking

I am talkingto you

Page 57: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 57

= is the difference in travel time on the 4 pairs (expressed in nsec)

Delay Skew

Delay Skew

Page 58: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 58

1000 MbitMessage

250 Mbps

250 Mbps

250 Mbps

250 Mbps

A B C D

B D A C

Delay Skew too high!

=

????????

=

Delay Skew

Page 59: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 59

Delay Skew : example < 50 nsec

Channel with a delay Skew of more than 50 nsec cannot

successfully support Gigabit Ethernet

Delay Skew

Page 60: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 60

Megabits or MegaHertz ? ? ?

Attenuation

Near-End Crosstalk

Attenuation to Crosstalk Ratio

PowerSum Next, PowerSum ACR

ELFEXT, PowerSum ELFEXT

Delay Skew

Return Loss

Coupling Attenuation

Electromagnetic Interference

Technical Knowledge

Page 61: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 61

Return Loss

= Return Loss (or Transmit Echo) is expressing the reflection of a signal on the same wire pair

Return loss

Page 62: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 62

Return Loss

A measure of the strength of reflected signal echoes

Caused by impedance mismatches along a cable run

Signal echo is an additional noise source

Return loss

Page 63: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 63

TX -+

RX

Return Loss

In Gigabit Ethernet : Return Loss will be cancelled out !

Return loss

Page 64: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 64

Megabits or MegaHertz ? ? ?

Attenuation

Near-End Crosstalk

Attenuation to Crosstalk Ratio

PowerSum Next, PowerSum ACR

ELFEXT, PowerSum ELFEXT

Delay Skew

Return Loss

Coupling Attenuation

Electromagnetic Interference

Technical Knowledge

Page 65: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 65

Powersum NEXT Powersum ELFEXT

Ambient noise Noise sources

Technical Knowledge

Delay Skew

Return Loss

Page 66: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 66

Background noise such as noise generated by power lines, telephone voltages, airco’s or engines, …

Due to its random nature, ambient noise can not be cancelled out in the NIC and it will contribute to the BER of a system

Ambient noise

Ambient Noise

Page 67: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 67

New parameter studied in European Standardisation (CENELEC)

Included in last edition of ISO 11801 and EN 50173

Nexans is one of the pioneers in the work on coupling attenuation

Measures the electromagnetic isolation between a disturbing source (ambient noise) and the cabling expresses the overall EMC performance of cabling

Coupling Attenuation

Coupling attenuation

Page 68: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 68

Sources of Electromagnetic InterferenceSources of Electromagnetic Interference EnginesEngines ElevatorsElevators GSM / Walkie TalkiesGSM / Walkie Talkies 230 V cabling230 V cabling high voltage cableshigh voltage cables Air conditionersAir conditioners TL lighting (HF)TL lighting (HF) Heating sources/ Micro waves/ radarsHeating sources/ Micro waves/ radars RefrigeratorsRefrigerators PhotocopiersPhotocopiers Pencil sharpenersPencil sharpeners Light DimmersLight Dimmers

EMI

Page 69: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 69

Protection against ambient noise determined by

Balance Screening

Now specified by parameter COUPLING ATTENUATION

Coupling Attenuation

Page 70: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 70

Influence of Noise

Signal/Noise Ratio (SNR) is more important with higher levels of coding

Page 71: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 71

uncontrollable influence from the outside

Electromagnetic Interference (EMI)

EMI

Page 72: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 72

Solution : Close the window, use a screen !!!

EMI

Page 73: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 73

antenna

1) How does a radio pick up signals ?

EMI

Page 74: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 74

radiation

2) Why is a mobile phone not allowed in hospitals, airplanes and in gasoline stations ?

EMI

Page 75: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 75

Faradaycage

3) Why is the housing of a desktop in metal ?

EMI

Page 76: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 76

IMMUNITY OF TWISTED PAIR AT LOW FREQUENCIES

EMI

Page 77: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 77

IMMUNITY OF INSTALLED TWISTED PAIR AT LOW FREQUENCIES

Bending

EMI

Page 78: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 78

EMI

IMMUNITY OF INSTALLED TWISTED PAIR AT HIGH FREQUENCIES

Page 79: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 79

Bending

EMI

IMMUNITY OF INSTALLED TWISTED PAIR AT HIGH FREQUENCIES

Page 80: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 80

10 dB x better EMC performance !

EMIEMI

EMIEMI

40 m

2 x 25 m

Nexans’ dual foil cables

Single foil FTP cables

EMI

Page 81: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 81

OVERALL SHIELD MADE OF TWO FOILS !

HIGHER EMC PERFORMANCES !

better Coupling Attenuation, better shield effectiveness

GAIN ON INSTALLATION !No risk to cut the foil off when strippingOnly one foil to connectMore flexible foils easier to manipulateQuick and reliable installation

EFFECTIVE SOLUTION !Easy connection of one overall foil provides EMC performances comparable to S-FTP.

FTP

Dual Foil

40 µm

2x 25 µm

Page 82: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 82

EFFICIENCY OF THE FOIL

Current flowin the foil

“Skin effect”

Thicknessof the foil

Internallyinducedcurrents

Externallyinducedcurrents

EMI

Page 83: Nexans Cabling Solutions, Jan 2004 1 Nexans Cabling Solutions, Jan 2004 2 Facts about Nexans Technics  Cabling evolution  Parameters Cat 6 versus Cat.

Nexans Cabling Solutions, Jan 2004 83

Nexans is the inventor and first developer of FTP, combining advantages of UTP and STP

Nexans Cabling Solutions is the world leader in screened cabling solutions

Full range of screened cables and connectivity, offering a full EMC cabling system

Grounding and Earthing considered during design

SCREENED CABLING TECHNOLOGY

EMI