Newtec SCADA Solution Guide

download Newtec SCADA Solution Guide

of 8

Transcript of Newtec SCADA Solution Guide

  • 7/30/2019 Newtec SCADA Solution Guide

    1/8

    SHAPING THE FUTURE OF SATELLITE COMMUNICATIONS

    APPLICATION NOTE

    SCADA

    The ability to remotely monitor, control and

    report on the results o distributed assets is key

    to achieving maximum operational efciency.

    The abundance o measuring and control points

    requires an efcient delivery system to balance

    network cost versus operational requirements.Beyond supporting traditional SCADA

    applications, the industry is looking or ways to

    receive real-time visuals rom their remote sites.

    By oering an extremely cost eective terminal

    as part o a scalable network solution, value

    can be provided or operational managers in the

    felds o earthquake monitoring acilities, oil and

    gas inrastructure, utilities, transport, energy

    distribution and environmental monitoring

    anywhere in the world. The advent o largescale renewable energy acilities like windmill

    parks in inhospitable areas can beneft rom a

    SCADA network to optimize efciency o energy

    generation and transportation.

    How to monitor and control yourbusiness operation in the mostcost eective way.

    Supervisory Control and Data Aquisisiton

  • 7/30/2019 Newtec SCADA Solution Guide

    2/8

    SHAPING THE FUTURE OF SATELLITE COMMUNICATIONS

    APPLICATION NOTE

    SCADA

    Newtecs Sat3Play provides the means to establish an

    always-on two-way IP connectivity between a Remote

    Terminal Unit (RTU) and the Internet or a private network,

    thereore remaining completely independent rom existing

    terrestrial networks.

    The basic IP connectivity is extended with Quality o Service

    (QoS) in orward and return allowing the deployment o real

    time services.

    The system consists o a gateway that can support up to

    50,000 remote terminals with a variety o service levels. Thegateway contains management unctionalities to monitor,

    confgure and control remote sites in large geographical

    areas. Individual service confgurations can be confgured

    to meet specifc requirements o a remote site.

    To make satellite an attractive alternative or SCADA the

    Sat3Play terminal implements the most bandwidth

    efcient technologies, such as DVB-S2 ACM orward

    link, 4CPM adaptive return link and embedded IP trafc

    enhancement sotware.

    How it works

    always-on two-way IP connectivitybetween a RemoteTerminal Unit (RTU)and the Internet or aprivate network.

    Sat3PlayGateway

    Control Center

    RTUData VideoInternetor

    private network

  • 7/30/2019 Newtec SCADA Solution Guide

    3/8

    SHAPING THE FUTURE OF SATELLITE COMMUNICATIONS

    APPLICATION NOTE

    SCADA

    Security

    Confdentiality o exchanged inormation is guaranteed.

    Data can be directly communicated to the RTU using a

    single satellite hop. The communication end-points are

    authenticated which increases the security o the SCADA

    network.

    Since the encryption is ully integrated in the system, it can

    be combined with trafc acceleration and compression

    resulting in real time network behaviour comparable to

    traditional delivery networks.

    High availability at minimum cost

    Newtecs simple, yet very efcient implementation oACM (Adaptive Coding and Modulation), doubles satellite

    throughput and customer satisaction by providing 100 per

    cent link availability.

    ACM technology is incorporated into the DVB-S2 standard,

    providing signifcant increases in bandwidth efciency

    or satellite applications and allowing modifcation o

    modulation parameters o a satellite signal during

    almost any orm o intererence, without interrupting the

    transmission or losing data.

    Since statistically rain ades are short and happen quiterarely over time, higher modulation parameters can be

    used most o the time. However, when SCADA requires a

    fxed transmission rate or a permanent high availability, the

    ACM technology assures that the ade only aects one o

    the services. This mechanism gives the platorm extremely

    high availability at no additional space segment cost.

    Depending on the instant need at a certain location the

    required capacity can be variant. The Sat3Play system is

    capable o dynamically allocating capacity over the dierent

    remote sites.

  • 7/30/2019 Newtec SCADA Solution Guide

    4/8

    SHAPING THE FUTURE OF SATELLITE COMMUNICATIONS

    APPLICATION NOTE

    SCADA

    Carrier grade availability 99.99 per cent

    The gateway provides redundancy on all layers (user,

    control, management) and equipment. It has redundant

    RF signal and mains supply inputs. The redundancy isconceived as two ully redundant chains. When there

    is a ailure an automatic switch over to the other chain

    is perormed. Even during service windows there is

    limited downtime since upgrades can be perormed

    on one o the chains with the other chain active in a

    previous version. A ailure in the ront-end is resolved by

    switching to the alternative RF input.

    Network Scaling

    The Sat3Play network supports services ranging

    rom data only to voice and video. For many SCADA

    applications adding video will provide extra inormation

    when abnormal events are detected. Integrating Video

    Trafc in the SCADA network will improve operation

    efciency by providing greater insight into events and

    thus diminishing the potential or damage caused by

    emergency events.

    EFFECTIVELY MANAGE

    CHANGE

    Operational: seamless

    upgrades with limited

    service down time

    Financial: gradualinvestment in gateway

    inrastructure over time

    Critical Response Time Traffic

    Time

    Video Traffic

    Non real Time

  • 7/30/2019 Newtec SCADA Solution Guide

    5/8

    SHAPING THE FUTURE OF SATELLITE COMMUNICATIONS

    APPLICATION NOTE

    SCADA

    The Sat3Play system can have the

    highest amount o terminals active

    with real-time response behaviour.

    This system eature enables users to

    deploy large amounts o terminals ona minimal gateway estate.

    The modular and scalable gateway

    allows users to start with a small

    scale installation, expanding it by

    means o a sotware license and

    gradually adding additional modules

    as the network grows or applications

    are added. The unique pay as you

    grow principle matches the inherent

    changes in size or capacity o the

    network with a exible investment

    model.

    Versatile Service Guarantees

    The Sat3Play system provides 3

    classes o services: best-eort, high-

    priority and real-time. Each o those

    trafc classes has specifc transportation and shaping

    characteristics. The real-time trafc class assures that

    delay and jitter perormance are controlled even in ading

    and congested conditions.

    In a typical SCADA scenario the high priority class

    would be used or the monitoring and control trafc.

  • 7/30/2019 Newtec SCADA Solution Guide

    6/8

    SHAPING THE FUTURE OF SATELLITE COMMUNICATIONS

    APPLICATION NOTE

    SCADA

    The real-time class would carry the video trafc that

    was triggered by an alarm or an operator request. It is

    guaranteed that this trafc would not interere with critical

    SCADA trafc. The real-time class can also be used or

    local technician service calls. The best eort class is thenused or carrying on-site internet or intranet access.

    Fast deployment

    Sat3Play can be operated as a single service provider

    platorm or a multi-service provider platorm. The latter gives

    the opportunity to start a service without investing into a ull

    system.

    The installation o the terminal can be done without any

    specifc training. This means a correct and ast installation

    can be perormed by a local technician o the remote site

    with no need or special equipment. The local technician is

    guided to perorm the correct antenna pointing by the Point

    & Play tool. The terminal comes pre-confgured so no

    on-site administration is required, resulting in ast and riskree deployment.

    Take advantage o

    the real time service

    class to view imageso a guarded zone and

    permit the verifcation

    o alse alarms.

    Fast and risk ree

    installation by on-site

    technician. No special

    equipment needed.

  • 7/30/2019 Newtec SCADA Solution Guide

    7/8

    SHAPING THE FUTURE OF SATELLITE COMMUNICATIONS

    APPLICATION NOTE

    SCADA

    Low power consumption

    The terminal only consumes 20W typical and the DC

    power supply fts alternative power sources like solar

    cells.

    The low power consumption o the terminal fnds

    its origin in the interactive LNB. It has a simple up-

    conversion architecture and uses saturated power

    amplifcation without any perormance penalty.

    For further in depth information

    Sat3Play Leaets

    Visit our website: www.newtec.eu

  • 7/30/2019 Newtec SCADA Solution Guide

    8/8

    Newtec

    South America

    Newtec

    North AmericaNewtec

    China

    Newtec

    Asia Pacific

    Newtec

    MENA

    Europe North-America South-America Asia-Pacifc China MENA

    Tel: +32 3 780 65 00 Tel: +1 203 323-0042 Tel: +55 11 2092 6220 Tel: +65 6777 22 08 Tel: +86 10-823 18 730 Tel: +971 4 390 18 78

    Fax: +32 3 780 65 49 Fax: +1 203 323-8406 Fax: +55 11 2093 3756 Fax: +65 6777 08 87 Fax: +86 10-823 18 731 Fax: +971 4 368 67 68

    Newtec Europe