Title Cold Model Test of A Four Vane RFQ for Multi-Purpose Use Linac Author(s) Ikeda, Kazumi; Kan, Taro; Yoshizawa, Kunio; Hirota, Jitsuya; Iwashita, Yoshihisa; Okamoto, Hiromi; Noda, Akira; Inoue, Makoto Citation Bulletin of the Institute for Chemical Research, Kyoto University (1992), 70(1): 99-108 Issue Date 1992-03-30 URL http://hdl.handle.net/2433/77428 Right Type Departmental Bulletin Paper Textversion publisher Kyoto University

Transcript of New Title Cold Model Test of A Four Vane RFQ for Multi-Purpose … · 2012. 7. 12. · Kazumi...

Page 1: New Title Cold Model Test of A Four Vane RFQ for Multi-Purpose … · 2012. 7. 12. · Kazumi IKEDA*, Taro KAN*, Kunio YOSHIZAWA*, Jitsuya HIROTA*, Yoshihisa IWASHITA**, Hiromi OKAMoTO**,

Title Cold Model Test of A Four Vane RFQ for Multi-Purpose UseLinac

Author(s)Ikeda, Kazumi; Kan, Taro; Yoshizawa, Kunio; Hirota, Jitsuya;Iwashita, Yoshihisa; Okamoto, Hiromi; Noda, Akira; Inoue,Makoto

Citation Bulletin of the Institute for Chemical Research, KyotoUniversity (1992), 70(1): 99-108

Issue Date 1992-03-30

URL http://hdl.handle.net/2433/77428

Right

Type Departmental Bulletin Paper

Textversion publisher

Kyoto University

Page 2: New Title Cold Model Test of A Four Vane RFQ for Multi-Purpose … · 2012. 7. 12. · Kazumi IKEDA*, Taro KAN*, Kunio YOSHIZAWA*, Jitsuya HIROTA*, Yoshihisa IWASHITA**, Hiromi OKAMoTO**,

Bull. Inst. Chem. Res., Kyoto Univ., Vol. 70, No. 1, 1992

Cold Model Test of A Four Vane RFQ

for Multi-Purpose Use Linac

Kazumi IKEDA*, Taro KAN*, Kunio YOSHIZAWA*, Jitsuya HIROTA*, Yoshihisa IWASHITA**, Hiromi OKAMoTO**, Akira NoDA** and Makoto INOUE**

Received February 7, 1992

RF characteristics of a four vane RFQ linac have been studied using a 400MHz cold model cavity with unmodulated vanes. The equivalent inner diameter and length of the cavity are 154.5 and 1220.0mm,

respectively and the dimensional errors of the gaps between the neighbouring vanes are within 0.03mm. The field distributions were measured using the Bead Perturbation Method and a field stabilization by

magnetic coupling between the quadrants was examined. It is possible to obtain the good field distributions by using the field stabilization scheme, whose azimuthal symmetry and longitudinal

uniformity are within ±1.3% respectively.

KEY WORDS : Proton Linac/ Four Vane RFQ/ Resonant Loop Ring/ Field Stabilization/ Cold Model Test

1. INTRODUCTION

A design study of a 10MeV proton linac for multi—purpose use has been carried on since April, 1990, in cooperation of the Institute for Chemical Research of Kyoto Univ., Mitsubishi

Heavy Industries, Ltd and Mitsubishi Atomic Power Industries, Inc.. It is intended in this study to investigate an optimum combination of accelerators such as RFQ and DTL to

accelerate proton beams from 50KeV to 10MeV. The average beam current is aimed to be 1 mA and the operating frequency is selected to be around 400MHz because of the requirement

for the neutron yield and the transportability of the Linac. As a part of this study, RF characteristics of a four vane RFQ linac have been studied

using a cold model cavity. The four vane cavity is operated in a TE210 mode and field distributions with azimuthal symmetry and longitudinal uniformity are required. If TElln

modes lie close to the TE210 mode, the mixing of these modes distorts the field distribution. Dimensional errors of the cavity also distort the field distribution. Furthermore, another ob-

jective of the cold model test is an experimental determination of the shape of the vane at the end, otherwise a three dimensional calculation is needed for the determination.

* %L~~1, q fnkg, : Mitsubishi Atomic Power Industries, Inc. ** f l* E, *E , 4± { : Facility of Nuclear Science Research, Institute for

Chemical Research, Kyoto University.

(99)

Page 3: New Title Cold Model Test of A Four Vane RFQ for Multi-Purpose … · 2012. 7. 12. · Kazumi IKEDA*, Taro KAN*, Kunio YOSHIZAWA*, Jitsuya HIROTA*, Yoshihisa IWASHITA**, Hiromi OKAMoTO**,

K. IKEDA, T. KAN, K. YOSHIZAWA, J. HIROTA, Y. IWASHITA, H. OKAMOTO, A. NODA and M. INOUE

2. STRUCTURE OF MODEL CAVITY

The equivalent inner diameter and length of the model cavity are 154.5 and 1220.0mm, respectively. The cavity-wall and vane are made of aluminum alloy (5052). The structure of the cavity is shown in Fig. 1. The vane tip is fabricated to have a curvature of 3.00±0.03mm. The cavity-wall and vanes had been so precisely assembled to make dimensional errors within 0.03mm in the gaps between the neighbouring vanes. The RF contactor used between the cavity-wall and vanes is the EMI shield spiral made of beryllium-copper alloy. The cavity-wall has 32 holes of 8mm in diameter and 4 holes of 20mm in diameter for the RF measure-ments. Opposed to the each vane end, eight end tuners are mounted on the end plates. The tuner is a copper rod of 12mm diameter and the tuner-to-vane gap is adjustable from 10.0 to 0mm with a micrometer head. There is a cutback at the each end of the each vane. The cutback space is adjustable by adding a cutback-block whose material and thickness are the same as those of the vane. Addition of the cutback-block causes a reduction of the inductance in the end region and increases the resonant frequency of the cavity.

A basic problem in the four vane RFQ is the balancing of the four quadrants. In general, the flatness in the field distributions is related to the separation of the TE210 mode from other modes. There are three methods to increase the mode separation and relax the tuning sen- sitivity. Thefirst method is the use of Vane Coupling Rings (VCR)I~, which directly connect opposing vanes with a low inductance. The second one makes magnetic coupling between the

quadrants with Resonant Loop Rings (RLR) 2' 3). And the third one is the use of 71- mode Stabilizing Loops (PISL) 4). Among these methods, the second scheme is preferable because the vanes are mechanically unstressed. The RLR mounted on the end plate of the model cavity is shown in Photo. 1. The RLRs mounted on both end plates are 90° turned each other corresponding to two dipole modes.

The Q value up to 3800 had been obtained by improvements of the contact between the

cavity-wall and vanes. The Q value calculated with SUPERFISH is 9250 for the infinitely

zo 0 QQ I II0 114

----- -o-

l-.; Ve.,r_j- I®-%

s 0I 0 O 23620 10

Q

Fig. 1. Structure of model cavity 1 End plate 3 RLR5 Cavity—wall 7 Cap bolt

2 End tuner 4 RF contactor - 6 Vane8 Cutback—block

(100)

Page 4: New Title Cold Model Test of A Four Vane RFQ for Multi-Purpose … · 2012. 7. 12. · Kazumi IKEDA*, Taro KAN*, Kunio YOSHIZAWA*, Jitsuya HIROTA*, Yoshihisa IWASHITA**, Hiromi OKAMoTO**,

Cold Model Test of a Four Vane RFQ

t.

tk

r -'

I 1'ac

jtr 1111° ~'^ ,F" R

° F

Photo. 1. RLR mounted on the end plate.

long cavity made of copper. Considering the difference of the electric conductivities between

copper and aluminum—alloy, the calculated value is corrected to 5470. The main reasons of

the difference between the corrected and measured values are considered to be the imperfect

contact between the cavity—wall and vanes, end effect, surface oxidation and holes.

3. RESONANT FREQUENCIES

Resonant frequencies for various modes were measured on the model cavity without the

RLRs and field tunings. The modes were identified by the polarity of the phase of the

magnetic field detected with a pick—up loop. The dispersion curves of these modes are shown

in Fig. 2. The measured resonant frequencies are 402.25MHz for the TE210 mode, and 396.86

and 397.78 MHz for the TE110 modes. The mode separation is pretty good in this short

model cavity since the nearest TE110 mode lies about 4.5MHz apart from the TE210 mode.

The values calculated with SUPERFISH are 409.84MHz for the TE210 and 398.66MHz for

the TE110 mode, respectively. The measured frequencies for the dipole modes are higher than

those for the quadrupole modes except for the lowest mode. This situation is considered to be

caused by the different effects from the shape of the end region including the cutback.

The increases in the resonant frequencies for the TE210 and TE110 modes were measured

reducing the cutback spaces on both sides by using the cutback—blocks. The measured in-

creases in the resonant frequency for the TE210 mode are 0.90, 2.06 and 3.34MHz when the

cutback spaces are reduced by 12.6, 25.1 and 37.7%, respectively. The measured increases in

(101 )

Page 5: New Title Cold Model Test of A Four Vane RFQ for Multi-Purpose … · 2012. 7. 12. · Kazumi IKEDA*, Taro KAN*, Kunio YOSHIZAWA*, Jitsuya HIROTA*, Yoshihisa IWASHITA**, Hiromi OKAMoTO**,

K. IKEDA, T. KAN, K. YOSHIZAWA, J. HIROTA, Y. IWASHITA, H. OKAMOTO, A. NODA and M. IN0uE

500------------------------- —0— TE2

I11-1.(Q) ,~--•-- TE l l n (D)

N 480. I'

460/1 ------------------------------------------

/

C/ /

N4 4 O/-------------

/ G /

L14

u 420 ----------------------------------------

~0ro' 4-00 ° —

v

380---------------------------------------- 01 2

Mode Number

Fig. 2. Dispersion curves without RLRs and field tunings.

Z

o--------------------~—

L1.0

o

ro -2 .0

N N a

0 —3.0 ----------------------------------------------------------------, O

ro -4 _O------------------------------------------------------

U O 2_0 4.0 6.0 8.0 10.0

End Tuner Gaps (mm)

Fig. 3. Effect of end tuners on the resonant frequency for the TE210 mode.

the resonant frequencies for the TE110 modes are about 10% less than these values, respec-

tively. It can be said that the measured frequency for the TE210 mode agrees rather well with

the calculated value if the effect of the cutback on the resonant frequency is taken into ac-

count which can not be treated by SUPERFISH. In Fig. 3, measured decreases in the

( 102 )

Page 6: New Title Cold Model Test of A Four Vane RFQ for Multi-Purpose … · 2012. 7. 12. · Kazumi IKEDA*, Taro KAN*, Kunio YOSHIZAWA*, Jitsuya HIROTA*, Yoshihisa IWASHITA**, Hiromi OKAMoTO**,

Cold Model Test of a Four Vane RFQ

resonant frequency for the TE210 mode are shown when all the end tuner gaps on both sides

are decreased stepwise to 1.0 from 10.0mm.

An evaluation of the effects of the RLR scheme on the mode separation and the field

stabilization is one of the main objectives of this cold model test. The shifts of the resonant

frequencies for the TE110 and TE111 modes were measured on the cavity with the cutback

spaces reduced by 25.1%, changing the distance between the RLR ring and end plate. The

results are shown in Fig. 4. As expected, the resonant frequencies for the quadrupole modes

are not affected by RLRs. Prior to these measurements, the resonant frequency of the RLR

mounted on the end plate which was removed from the cavity—wall was related to the distance

between the ring and end plate. The results are shown in Fig. 5.

The separation between the TE210 mode and TE110 modes increases to the value more

than 10MHz when the distance between the ring and end plate is nearly 2.5mm as seen in Fig.

4, although the identification of the TE110 modes is rather difficult in the transition stage. The separation between the TE211 mode and TE111 modes also increases when the distance is

nearly 3.5mm. Therefore, it can be concluded that the RLR scheme is effective on the mode

separation even in case of our cavity whose ratio of the length to the free space wavelength of

the operating frequency is about 1.6.

450•

x _ x

-------- TE211

QI TE 1 1 1

(+ _----------------------TE2 1 O 400~-~~8'' 2-------- e TE1 10

ro ,a

0

350.------------------------------------------------------ O 2.0 4_O - 6_0 8_0

Distance between Ring and End Plate(mm)

Fig. 4. Shift of resonant frequencies for the TE110 and TE111 modes by RLRs. '-

(103)

Page 7: New Title Cold Model Test of A Four Vane RFQ for Multi-Purpose … · 2012. 7. 12. · Kazumi IKEDA*, Taro KAN*, Kunio YOSHIZAWA*, Jitsuya HIROTA*, Yoshihisa IWASHITA**, Hiromi OKAMoTO**,

K. IKEDA, T. KAN, K. YOSHIZAWA, J. HIROTA, Y. IWASHITA, H. OKAMOTO, A. NODA and M. INOUE

. n. 450 • N RLR.

xSide A

A/' a A Side B

0 -4/

0 a~~a Awo 400-A

t C/c

0

a

A

350 1 2_0 4-0 6-0 8-0

Distance between Ring and End Plate(mm)

Fig. 5. Resonant frequency of the RLR vs the distance between the ring and end plate.

4. FIELD DISTRIBUTIONS

Magnetic and electric field distributions were measured using the Bead Perturbation

Method. An aluminum cylindrical bead of 4.5mm diameter and 9.0mm length is inserted through holes of the end plates into a quadrant at 50mm off axis to measure the magnetic field

distribution. And an aluminum bead of 3.0mm diameter and 3.0mm length is inserted along

the axis to measure the electric field distribution. The drive mechanism of the beads mounted

on the end plate is shown in Photo. 2. A nylon string of 0.235mm diameter tensioned by a

spring is used to carry the bead. The magnetic field distributions in the four quadrants can be

measured sequentially without opening up the end plates because the string is set in each

quadrant. The field distributions shown in Fig. 6a are those measured in the four quadrants of the

cavity without the RLRs and field tunings. The fields are strong in the Quadrant-1 and 4,

and weak in the Quadrant-2 and 3 revealing dimensional errors of the gaps between the

neighbouring vanes. The longitudinal field distributions are bowed indicating improper

dimensions of the cutback spaces. The field distributions compensated by using the cutback-

blocks and end tuners are shown in Fig. 6b. The azimuthal field symmetry is within ±2.3% and the longitudinal field distributions are uniform within ±3.1%. It is impossible to improve

the azimuthal field symmetry by using only the cutback-blocks.

( 104 )

Page 8: New Title Cold Model Test of A Four Vane RFQ for Multi-Purpose … · 2012. 7. 12. · Kazumi IKEDA*, Taro KAN*, Kunio YOSHIZAWA*, Jitsuya HIROTA*, Yoshihisa IWASHITA**, Hiromi OKAMoTO**,

Cold Model Test of a Four Vane RFQ

AV

s_4

Photo. 2. Drive mechanism of beads for field measurements.

In order to examine the effect of the RLRs on the field stabilization, the field distribu-

tions were measured on the cavity with the cutback spaces reduced by 25.1%, changing the

distance between the RLR ring and end plate. It was observed that the field distributions were

largely disturbed when the distance was about 2.5mm. The RLR should be tuned to some fre-

quency which is lower than the resonant frequency for the TE210 mode and higher than the resonant frequencies for the TE110 modes.

The field distributions shown in Fig. 7a are those generated when the distance between the

ring and end plate is 2.2mm on the side A and 1.9mm on the side B of the cavity. The

balancing of the four quadrants is almost similar to that in Fig. 6a. However, these field

distributions can be improved very easily by using the end tuners. The field distributions

shown in Fig. 7b are those obtained after the field tunings. The distance between the ring and

end plate is 2.2mm on the side A and 2.0mm on the side B. The azimuthal symmetry and

longitudinal uniformity of the field distributions are within ±1.3% respectively. It should be

noted that the field distributions are much improved comparing with those in Fig. 6b. The

uniformity of the electric field distribution along the axis is also comfirmed. Therefore, it can

be concluded that the RLR scheme is effective to improve the field distributions in case of our

cavity.

(105)

Page 9: New Title Cold Model Test of A Four Vane RFQ for Multi-Purpose … · 2012. 7. 12. · Kazumi IKEDA*, Taro KAN*, Kunio YOSHIZAWA*, Jitsuya HIROTA*, Yoshihisa IWASHITA**, Hiromi OKAMoTO**,

K. IKEDA, T. KAN, K. YOSHIZAWA, J. HIROTA, Y. IWASHITA, H. OKAMOTO, A. NODA and M. INOUE

End Tuner Gap (mm) 1 2

4 •1-2 2-3 3-4 4-1 1' 8_ O.

•el4xSide A 10.0 10.0 10.0 10 0 3Sid e B 10.0 10.0 10.0 10.0

Cutback; 30-0 x 39-8 mm >„.0 uX\ojX' x

!J7_O'

A- o=~~— x~-2F~ do•

6.0-~~~^/°^~

Side ASide B (a)

End Tuner Gap (mm) 2 a e1-2 2-3 3-4 4-1 .,{ 8 - 0-X p 3Side A 10.0 10.0 10.0 2.0

Side B 10.0 10.0 10.0 2.0

Cutback; reduced by 25_1 ro

la 7 -0-

A~ —x X-- x—

6-0-

Side A Side B (b)

Fig. 6. Field distributions in the cavity without RLRs. (a) Before field tunings (f0=402.18 MHz)

(b) After field tunings (f0=403.99 MHz)

5. CONCLUSIONS

The RFQ cold model cavity with unmodulated vanes of 1200mm length had been so

precisely fabricated and assembled as to make dimensional errors within 0.03mm in the gaps between the neighbouring vanes. Using this model cavity, RF characteristics of the four vane

RFQ linac have been studied : The resonant frequency measured for the TE210 mode agrees

rather well with the value calculated by SUPERFISH. The azimuthal symmetry and

longitudinal uniformity of the field distributions obtained after field tunings were within ±

2.3% and ±3.1%, respectively. The RLR scheme is effective to separate the nearest TE110 mode from the TE210 mode and improve the field distributions even in case of our cavity

( 106 )

Page 10: New Title Cold Model Test of A Four Vane RFQ for Multi-Purpose … · 2012. 7. 12. · Kazumi IKEDA*, Taro KAN*, Kunio YOSHIZAWA*, Jitsuya HIROTA*, Yoshihisa IWASHITA**, Hiromi OKAMoTO**,

Cold Model Test of a Four Vane RFQ

End Tuner Gap (mm) ^J10I.2 1-2 2-3 3-4 .4-1

'4 8.0.S;de A 10.0 10.0 10.0 10 0

]4X IA3Side B 10.0 10.0 10.0 10.0 Cutback; reduced by 25_1 Li

c.X~X 4 •7.0-

AX0/o / 00 ~X

•6 _ o - d

Side ASide B (a)

End Tuner Gap (mm) t

o •21-2 2-3 3-4 4-I •d 8 _ 0-

4X p3Side A 10.0 10.0 10.0 1.8 r7 _ Side B 10.0 10.0 10.0 1.8

Cutback; reduced by 25.1 II

1J 7-0-

:(46_0

Side ASide B (b)

Fig. 7. Field distributions in the cavity with RLRs (a) Before field tunings (f0=404.39 MHz) (b) After field tunings (f0=404.05 MHz)

whose ratio of the length to the free space wavelength of the operating frequency is about 1.6.

If the RLRs are used, it is possible to achieve the good field distributions whose azimuthal

symmetry and longitudinal uniformity are within ±1.3% respectively.

ACKNOWLEDGEMENTS

The authors would like to express their thanks to Dr. H. Takekoshi, former Professor of

the Institute, for his support and encouragement at the initial stage of the study. They also

wish to thank Mr. K. Maruoka of Mitsubishi Heavy Industries, Ltd. and Mr. Y. Hasegawa of

Mitsubishi Atomic Power Industries, Inc. for the cooperations in this work.

( 107 )

Page 11: New Title Cold Model Test of A Four Vane RFQ for Multi-Purpose … · 2012. 7. 12. · Kazumi IKEDA*, Taro KAN*, Kunio YOSHIZAWA*, Jitsuya HIROTA*, Yoshihisa IWASHITA**, Hiromi OKAMoTO**,

K. IKEDA, T. KAN, K. YOSHIZAWA, J. HIROTA, Y. IWASHITA, H. OKAMOTO, A. NODA and M. INOUE

REFERENCES

1) D. Howard and H. Lancaster : "Vane Coupling Rings : A Simple Technique for Stabilizing A Four—Vane Radiofrequency Quadrupole Structure", IEEE Trans. Nucl. Sci., Vol. NS-30, No. 2, p. 1446 (1983).

2) A. Schempp et al.: "RFQ—Injector for HERA", IEEE Trans. Nucl. Sci., Vol. NS-32, No. 5, p. 3252 (1985).

3) A. Schempp et al. : "The HERA RFQ", PAC 87 Vol. 1, p. 361 (1987). 4) A. Ueno : "RFQ Linac", JHP-14, KEK Int. 90-16 (1990) (in Japanese).

(108)