New anechoic chamber results and comparison with field and ... · New anechoic chamber results and...
Transcript of New anechoic chamber results and comparison with field and ... · New anechoic chamber results and...
![Page 1: New anechoic chamber results and comparison with field and ... · New anechoic chamber results and comparison with field and robot techniques B. Görres, J. Campbell, M. Siemes ...](https://reader033.fdocuments.net/reader033/viewer/2022052518/5f0593c17e708231d413a6ba/html5/thumbnails/1.jpg)
1IGS Meeting Bern 2004 Görres et al.: New anechoic chamber results and comparisons ...
New anechoic chamber resultsand comparison
with field and robot techniques
B. Görres, J. Campbell, M. SiemesGeodätisches Institut der Universität Bonn
M. BeckerUniversität der Bundeswehr, München
![Page 2: New anechoic chamber results and comparison with field and ... · New anechoic chamber results and comparison with field and robot techniques B. Görres, J. Campbell, M. Siemes ...](https://reader033.fdocuments.net/reader033/viewer/2022052518/5f0593c17e708231d413a6ba/html5/thumbnails/2.jpg)
2IGS Meeting Bern 2004 Görres et al.: New anechoic chamber results and comparisons ...
German bench mark test 2002
Trimble microcenteredwith Ground PlaneTRM33429.20+GP
Leica AT withRadome
LEIAT303 LEIC
Leica AT 502
LEIAT502
Trimble Zephyr geodetic
TRM39105.00
Novatel 503 Choke Ring
with Radome
NOV503 NOKE
�Feldmann-Westendorff 2002)
Motivation: get better insight into the performance of different calibration methods
by calibration of a set of identical antennas at different institutions
GNPCVrobot –absolute
University ofHannover
not availablein spring ´02
chambertest
University ofBonn
Bernese GPSSoftware
relative fieldcalibration
University ofBonn
WaSoft/Kalibrelative fieldcalibration
University ofDresden
WaSoft/Kalibrelative fieldcalibration
State Survey...Niedersachsen
GNPCVrobot –absolute
Geo++Garbsen
usedSoftware
CalibrationMethodInstitution
![Page 3: New anechoic chamber results and comparison with field and ... · New anechoic chamber results and comparison with field and robot techniques B. Görres, J. Campbell, M. Siemes ...](https://reader033.fdocuments.net/reader033/viewer/2022052518/5f0593c17e708231d413a6ba/html5/thumbnails/3.jpg)
3IGS Meeting Bern 2004 Görres et al.: New anechoic chamber results and comparisons ...
German bench mark test 2002Results for Leica AT303
(Schmid et al. 2002)
![Page 4: New anechoic chamber results and comparison with field and ... · New anechoic chamber results and comparison with field and robot techniques B. Görres, J. Campbell, M. Siemes ...](https://reader033.fdocuments.net/reader033/viewer/2022052518/5f0593c17e708231d413a6ba/html5/thumbnails/4.jpg)
4IGS Meeting Bern 2004 Görres et al.: New anechoic chamber results and comparisons ...
0
0,20,4
0,60,8
11,2
1,41,6
(mm
)
IfE Geo++ LGN TUD GIB
RMS(Ele) L1 RMS(Ele) L2
German bench mark test 2002Results for Leica AT303
(elevation-dependent PCV)
the robot measurements (IfE and Geo++) agree on the level of 1mm
the standard field calibrations display larger variations of 2 mm (L1) and 4mm (L2)
? Confirmation of absolute results by an independent technique and identical antenna ?
![Page 5: New anechoic chamber results and comparison with field and ... · New anechoic chamber results and comparison with field and robot techniques B. Görres, J. Campbell, M. Siemes ...](https://reader033.fdocuments.net/reader033/viewer/2022052518/5f0593c17e708231d413a6ba/html5/thumbnails/5.jpg)
5IGS Meeting Bern 2004 Görres et al.: New anechoic chamber results and comparisons ...
EMV-Testzentrum der Bundeswehr in Greding
Largest anechoic chamber in Europe
• 41 x 16 x 14 m
• absorbing material suited for
frequencies > 0.5 GHz
![Page 6: New anechoic chamber results and comparison with field and ... · New anechoic chamber results and comparison with field and robot techniques B. Görres, J. Campbell, M. Siemes ...](https://reader033.fdocuments.net/reader033/viewer/2022052518/5f0593c17e708231d413a6ba/html5/thumbnails/6.jpg)
6IGS Meeting Bern 2004 Görres et al.: New anechoic chamber results and comparisons ...
GDI-bus
received GPS signal
trans
mitt
edsi
gnal
L1/L2
network analyser
test antenna
s � 18 m
Antenna measurement setup (pilot phase)
in the Greding chambertransmitting
antenna
control of themotion of
antenna mount
![Page 7: New anechoic chamber results and comparison with field and ... · New anechoic chamber results and comparison with field and robot techniques B. Görres, J. Campbell, M. Siemes ...](https://reader033.fdocuments.net/reader033/viewer/2022052518/5f0593c17e708231d413a6ba/html5/thumbnails/7.jpg)
7IGS Meeting Bern 2004 Görres et al.: New anechoic chamber results and comparisons ...
dr(�,�) = a · ro + �·d�(�,�)
with PCO: a(�) = (ax, ay, az)
Antenna Calibration Model
Two - Step Processing
1. Estimation of mean phase center offset (PCO) a with respect to the ARP: � d�(�,�) ² = Min!
2. PCV directly (no fit required!)
ARP
E
a
PCV =d� * � /360°
az
axr0
x
z
�
IdealePhasenfront
reale Phasenfront
![Page 8: New anechoic chamber results and comparison with field and ... · New anechoic chamber results and comparison with field and robot techniques B. Görres, J. Campbell, M. Siemes ...](https://reader033.fdocuments.net/reader033/viewer/2022052518/5f0593c17e708231d413a6ba/html5/thumbnails/8.jpg)
8IGS Meeting Bern 2004 Görres et al.: New anechoic chamber results and comparisons ...
geometric situation within the Chamber setup (pilot phase)
to get information about the scatter:
3a. Definition of a model function for the PCVe.g.: harmonic function dr(�) = � (akcos � + bksin �) , k = 0,...3, or 5
3b. Reprocessing of step 1 and re-estimation of normalized RMS
=> ay , az
=> ax , az
Estimation of PCO and PVC
![Page 9: New anechoic chamber results and comparison with field and ... · New anechoic chamber results and comparison with field and robot techniques B. Görres, J. Campbell, M. Siemes ...](https://reader033.fdocuments.net/reader033/viewer/2022052518/5f0593c17e708231d413a6ba/html5/thumbnails/9.jpg)
9IGS Meeting Bern 2004 Görres et al.: New anechoic chamber results and comparisons ...
Antenna Type IGS-Code
Trimblecompact
Trimble Zephyrgeodetic
stealth groundplane(anti-reflex)
LEIAT504 Dorne Margolin Antennawith chokerings(designed after D/M T)
LEIAT303_LEIC micropuls antennawith chokerings(identical to AT503)
TRM22020.00+GP with groundplane
TRM41249.00
Trimble geodetic TRM14532.00
Leica AT 303
Leica AT 504
Tested Antenna Types
![Page 10: New anechoic chamber results and comparison with field and ... · New anechoic chamber results and comparison with field and robot techniques B. Görres, J. Campbell, M. Siemes ...](https://reader033.fdocuments.net/reader033/viewer/2022052518/5f0593c17e708231d413a6ba/html5/thumbnails/10.jpg)
10IGS Meeting Bern 2004 Görres et al.: New anechoic chamber results and comparisons ...
-10
-8
-6
-4
-2
0
2
4
6
8
-90 -75 -60 -45 -30 -15 0 15 30 45 60 75 90
Zenit [Grad]
Phas
e [m
m]
Leica AT303 Leica AT504 Tr Geod Tr Zephyr Tr Compact
Phase pattern L1 (Elevation - Dependence)
measureded PCV values, no fitting function !
![Page 11: New anechoic chamber results and comparison with field and ... · New anechoic chamber results and comparison with field and robot techniques B. Görres, J. Campbell, M. Siemes ...](https://reader033.fdocuments.net/reader033/viewer/2022052518/5f0593c17e708231d413a6ba/html5/thumbnails/11.jpg)
11IGS Meeting Bern 2004 Görres et al.: New anechoic chamber results and comparisons ...
-10
-8
-6
-4
-2
0
2
4
6
8
-90 -75 -60 -45 -30 -15 0 15 30 45 60 75 90
Zenit [Grad]
Phas
e [m
m]
Leica AT303 Leica AT504 Tr geod Tr Zephyr Tr compact
Phase pattern L2 (Elevation - Dependence)
Asymmetry
![Page 12: New anechoic chamber results and comparison with field and ... · New anechoic chamber results and comparison with field and robot techniques B. Görres, J. Campbell, M. Siemes ...](https://reader033.fdocuments.net/reader033/viewer/2022052518/5f0593c17e708231d413a6ba/html5/thumbnails/12.jpg)
12IGS Meeting Bern 2004 Görres et al.: New anechoic chamber results and comparisons ...
-3
-2
-1
0
1
2
3
0 30 60 90 120 150 180 210 240 270 300 330 360
Azimut [Grad]
Phas
e[m
m]
Leica AT303 Leica AT504 Tr Geod Tr Zephyr
L1
Phase pattern (Azimuth - Dependence)Elevation 12.5°
-3
-2
-1
0
1
2
3
0 30 60 90 120 150 180 210 240 270 300 330 360
Azimut [Grad]
Phas
e[m
m]
Leica AT303 Leica AT504 Tr Geod Tr Zephyr
L2
![Page 13: New anechoic chamber results and comparison with field and ... · New anechoic chamber results and comparison with field and robot techniques B. Görres, J. Campbell, M. Siemes ...](https://reader033.fdocuments.net/reader033/viewer/2022052518/5f0593c17e708231d413a6ba/html5/thumbnails/13.jpg)
13IGS Meeting Bern 2004 Görres et al.: New anechoic chamber results and comparisons ...
0
0,05
0,1
0,15
0,2
0,25
0,3
0,35
Leica AT504 Leica AT303 TRM Comp +GP TRM Geodetic TRM Zephyr
sig0(Azi) L1 sig0(Azi)L2
notavailable
�mm)
Normalized RMS of PCV (mm)gives information about the scatter
after implementation of a harmonic function
0
0,05
0,1
0,15
0,2
0,25
0,3
0,35
Leica AT504 Leica AT303 TRM Comp+GP
TRMGeodetic
TRM Zephyr
sig0(Ele) L1 sig0(Ele) L2
�mm)
of azimuth-dependent PCVof elevation-dependent PCV
�mm)
![Page 14: New anechoic chamber results and comparison with field and ... · New anechoic chamber results and comparison with field and robot techniques B. Görres, J. Campbell, M. Siemes ...](https://reader033.fdocuments.net/reader033/viewer/2022052518/5f0593c17e708231d413a6ba/html5/thumbnails/14.jpg)
14IGS Meeting Bern 2004 Görres et al.: New anechoic chamber results and comparisons ...
-6,0
-4,0
-2,0
0,0
2,0
4,0
6,0
8,0
10,0
12,0
0 15 30 45 60 75 90 105 120 135 150 165 180
Elevation [Grad]
PCV
[mm
]
Greding Geo++
Comparison ofPhase pattern L1 (Elevation - Dependence)
Chamber (Greding) - absolut field calibration with robot (GEO++, Hannover)
Leica AT 303 (identical antenna)
![Page 15: New anechoic chamber results and comparison with field and ... · New anechoic chamber results and comparison with field and robot techniques B. Görres, J. Campbell, M. Siemes ...](https://reader033.fdocuments.net/reader033/viewer/2022052518/5f0593c17e708231d413a6ba/html5/thumbnails/15.jpg)
15IGS Meeting Bern 2004 Görres et al.: New anechoic chamber results and comparisons ...
-6,0
-4,0
-2,0
0,0
2,0
4,0
6,0
8,0
10,0
12,0
0 15 30 45 60 75 90 105 120 135 150 165 180
Elevation [Grad]
PCV
[mm
]
Greding Geo++
Comparison ofPhase pattern L2 (Elevation - Dependence)
Chamber (Greding) - absolut field calibration with robot (GEO++, Hannover)
Leica AT 303 (identical antenna)
![Page 16: New anechoic chamber results and comparison with field and ... · New anechoic chamber results and comparison with field and robot techniques B. Görres, J. Campbell, M. Siemes ...](https://reader033.fdocuments.net/reader033/viewer/2022052518/5f0593c17e708231d413a6ba/html5/thumbnails/16.jpg)
16IGS Meeting Bern 2004 Görres et al.: New anechoic chamber results and comparisons ...
-3,0
-2,0
-1,0
0,0
1,0
2,0
3,0
0 30 60 90 120 150 180 210 240 270 300 330 360
Azimut [Grad]
PCV
[mm
]
Greding L1 Geo++ L1
Leica AT 303 L1
Comparison of Phase pattern(Azimuth - Dependence, Elevation 12.5°)
Chamber (Greding) - absolut field calibration with robot(GEO++, Hannover)
Leica AT 303 (identical antenna)
-3,0
-2,0
-1,0
0,0
1,0
2,0
3,0
0 30 60 90 120 150 180 210 240 270 300 330 360
Azimut [Grad]
PCV
[mm
]
Greding L2 Geo++ L2
Leica AT 303 L2
![Page 17: New anechoic chamber results and comparison with field and ... · New anechoic chamber results and comparison with field and robot techniques B. Görres, J. Campbell, M. Siemes ...](https://reader033.fdocuments.net/reader033/viewer/2022052518/5f0593c17e708231d413a6ba/html5/thumbnails/17.jpg)
17IGS Meeting Bern 2004 Görres et al.: New anechoic chamber results and comparisons ...
Comparison of the Offsets between Chamber(Greding) and robot (GEO++)
=> �antcal2 = �PCO/PCV
2 + �D2
critical moment:
together with definition of ARP
Leica AT504 L1
-6,00
-4,00
-2,00
0,00
2,00
4,00
6,00
8,00
10,00
12,00
14,00
0 15 30 45 60 75 90 105 120 135 150 165 180
Elevation [Grad]
PCV
[mm
]
Greding L1 Geo++ L1
Leica AT504 L1
-8,00
-6,00
-4,00
-2,00
0,00
2,00
4,00
6,00
8,00
10,00
12,00
14,00
0 15 30 45 60 75 90 105 120 135 150 165 180Elevation [Grad]
PC
V [m
m]
Greding L1 Geo++ L1
-6
-4
-2
0
2
4
6
Leica AT504 Leica AT303 TRM Comp+GP
TRM Geodetic TRM Zephyr
(mm
)
D(az) L1 D(az) L2
Residual-Offsets
from best-fit between both patterns
![Page 18: New anechoic chamber results and comparison with field and ... · New anechoic chamber results and comparison with field and robot techniques B. Görres, J. Campbell, M. Siemes ...](https://reader033.fdocuments.net/reader033/viewer/2022052518/5f0593c17e708231d413a6ba/html5/thumbnails/18.jpg)
18IGS Meeting Bern 2004 Görres et al.: New anechoic chamber results and comparisons ...
0
0,2
0,4
0,6
0,8
1
1,2
(mm
)
Leica AT504 Leica AT303 TRM Comp+GP
TRMGeodetic
TRM Zephyr
sig0(Ele-comp) L1 sig0(Ele-comp)L2
Scatter between two different PCV patterns
after best-fit
Comparison of PCV
between Chamber (Greding) and robot (GEO++)
0
0,2
0,4
0,6
0,8
1
1,2
(mm
)
LeicaAT504
LeicaAT303
TRM Comp+GP
TRMGeodetic
TRMZephyr
sig0(Az-comp)L1 sig0(Az-comp)L2
not available
elevation-dependent azimuth-dependent
![Page 19: New anechoic chamber results and comparison with field and ... · New anechoic chamber results and comparison with field and robot techniques B. Görres, J. Campbell, M. Siemes ...](https://reader033.fdocuments.net/reader033/viewer/2022052518/5f0593c17e708231d413a6ba/html5/thumbnails/19.jpg)
19IGS Meeting Bern 2004 Görres et al.: New anechoic chamber results and comparisons ...
High potential for (receiver) antenna calibration in the anechoic chamber• Absolute calibrations from chamber measurements and robot agree on the
1 mm - level (identical antenna)• Significant variations in quality between antennas of different design• Anechoic chamber and robot permit homogenous distribution
of observations and quality of the PCV resultswith regard to the antenna hemisphere
• Direct representation of the measured PCV values(no fitting function needed)=> possibility to study the characteristics of the patterns in detail
Future: Develop operational procedure for chamber measurements by improved control of the motion of antenna mount => measure the whole hemisphere in an automatic mode
Conclusion