Neutron & Gamma Detectors ASSURE YOUR SAFETY · 2- Neutron flux for RPS, fuel loading, reactivity...

6
High Temperature for the toughest of requirements Sub-miniature Detectors for the closest range of measurement High Dynamic Range for the widest of flux variations ASSURE YOUR SAFETY Neutron & Gamma Detectors

Transcript of Neutron & Gamma Detectors ASSURE YOUR SAFETY · 2- Neutron flux for RPS, fuel loading, reactivity...

Page 1: Neutron & Gamma Detectors ASSURE YOUR SAFETY · 2- Neutron flux for RPS, fuel loading, reactivity meters, ex-core fission chamber and 10B proportional counter 3- Boron concentration

High Temperature for the toughest of requirements

Sub-miniature Detectors for the closest range of measurement

High Dynamic Range for the widest of flux variations

ASSUREYOURSAFETY

Neutron & Gamma Detectors

Page 2: Neutron & Gamma Detectors ASSURE YOUR SAFETY · 2- Neutron flux for RPS, fuel loading, reactivity meters, ex-core fission chamber and 10B proportional counter 3- Boron concentration

As a 1E, Safety critical, component supplier, Photonis defines your safety as its overriding priority.

The Nuclear Instrumentation staff answers to a Quality Management program that uses both training and independent inspections.

This QM program guarantees that you always get safety class components for your systems.

The Nuclear Instrumentation team is organized according to ISO9001. Product and supporting documentation are delivered according to your nuclear manufacturing standards such as IAEA50-C-G / KTA1401, RCCE (EDF rules), ASME, HAF604.

Assure your safety

Products & applications inside reactor buildings

Solutions for the complete neutron flux range

10B

coun

ters

fuel

load

ing,

so

urce

and

star

t-up

rang

e

inte

rmed

iate

and

pow

er ra

nge

Wid

e dy

nam

ic

fissi

on c

ham

bers

Mic

ro fi

ssio

n ch

ambe

rs

10-2 FP

1.5 Full Power

10-6 FP

10-12 FP

3

1 2

5 4

6

Photonis Neutron & Gamma Detectors

1- Neutron flux mapping, in-core fission chamber2- Neutron flux for RPS, fuel loading, reactivity meters, ex-core fission chamber and 10B proportional counter3- Boron concentration meters/cladding integrity, fission chamber and 10B proportional counter4- Signal transmission, mineral insulated cable extension and feedthrough5- Signal transmission, HN and extreme environment connectors6- Gamma flux monitoring for RMS, gamma chamber

Page 3: Neutron & Gamma Detectors ASSURE YOUR SAFETY · 2- Neutron flux for RPS, fuel loading, reactivity meters, ex-core fission chamber and 10B proportional counter 3- Boron concentration

Customer support activities Certifications & QA programs adapted to the customer environment

Technical support, applying detector expertise

Export control, as an Authorised Economic Operator, Photonis acts in accordance with EU and International regulations

Fissile material management & product storage

Customised products Customisation, development & innovation Adapt versions of industrialised products to customer specific requirements. Develop new detectors with our experienced R&D team.

Long term collaboration with the CEA (theoretical approach, modelling, qualification tests in research reactors).

Full control of the complete manufacturing process on site.

Support from all of the Photonis Group activities, experience and knowledge.

Tests and qualifications Photonis products have passed qualification tests that guarantee reliable operation in many harsh environments. However, new detectors or environments may require additional testing.

Photonis is committed to implement this qualification work.

Page 4: Neutron & Gamma Detectors ASSURE YOUR SAFETY · 2- Neutron flux for RPS, fuel loading, reactivity meters, ex-core fission chamber and 10B proportional counter 3- Boron concentration

Photonis Neutron & Gamma Detectors

Boron lined proportional counters

Gamma ionisation chambers

Extensions and feedthrough

Out-of-core fission chambers

In-core use fission chambers

* Operating characteristics depend on electronics ** Up to 600°C operational

* Operating characteristics depend on electronics ** Up to 600°C operational *** Guard-ring structure

* Operating characteristics depend on electronics

Type Ø (mm) Length (mm) Neutron sensitivity (cps/nv)

*Thermal Neutron flux range (nv)

CPNB48 25.4 560 10 10-1 - 2 x 105

CPNB44 48 761 8 10-1 - 2 x 105

CPNB64 76.5 702.5 25 5 x 10-2 - 5 x 104

CPNB84 82 702.5 50 5 x 10-2 - 2.5 x 104

Type Ø (mm) Length (mm) *Thermal Neutron flux range (nv)Pulse mode Current mode

CFUM11 25.4 227 10 - 107 107- 1011

CFUL08 48 384.5 1 - 106 104 - 1010

CFUC19** 48 421 2 - 2 x 106 2 x 104 - 2 x 1010

CFUP08*** 76.5 457 1 x 106 104 - 1010

CFUG08 80 419 0.2 - 2 x 105 105 - 7 x 1010

Type Ø (mm) Length (mm) *Thermal Neutron flux range (nv)Pulse mode Current mode

CFUZ53 1.5 50 - 2 x 1011- 1014

CFUR43 3 48.5 - 1011 - 1.5 x 1014

CFUR64 3 46 107 - 3 x 1011 1012 - 1014

CFUF43 4.7 86 - 1012 - 1014

CFUE24 7 150 102 - 107 108 - 1012

CFUE32** 7 150 103 - 108 109 - 1013

Type Mode MI cable Ø (mm) Ceramic insulator connectorEXT-BNC current 3 male / female BNC

EXT-HN current or pulse 4 or 6 male / female HN

EXT-R pulse 6 male / female reinforced HNTRAV pulse 6 feedthrough

Type Ø (mm) Length (mm) Gamma sensitivity(A/Gy.h-1 60Co)

CRGE10 7 85.5 4.5 x 10-11

CRGA11 18 234 1.5 x 10-10

CRGB10/Ne 48 137 6 - 10-10

CRGB10/Xe 48 137 7.2 - x 10-8

CRGJ15 56 195 5 x 108

Page 5: Neutron & Gamma Detectors ASSURE YOUR SAFETY · 2- Neutron flux for RPS, fuel loading, reactivity meters, ex-core fission chamber and 10B proportional counter 3- Boron concentration

• PWR – neutron flux mapping – in-core fission chambers CFUF – Belgium, China, France, South Africa, South Korea, Slovenia.• PWR – source range neutron flux monitoring – boron lined proportional counters CPNB – Belgium, China, France, South Africa, South Korea.• PWR – wide range neutron flux monitoring – ex-core fission chambers CFUG – Switzerland.• PWR – safety critical signal transmission in reactor building – mineral insulated cable extension – EXT-HN – France.• BWR – start-up and intermediate range – in-core movable fission chamber CFUE – Finland, Sweden.• VVER – source range neutron flux monitoring – boron lined proportional counters CPNB – Armenia, Czech Republic, Hungary, Russia, Slovakia.• VVER – wide range neutron flux monitoring – ex-core fission chambers CFUL – Hungary, Slovakia, Ukraine.

Other references• Fuel reprocessing plant – AREVA – numerous gamma ionization chambers, boron lined proportional counters and fission counters – France, Japan.• *ADS – wide range neutron flux monitoring – CFUL, CFUF – Belgium, Ukraine.• *FBR – wide range neutron flux monitoring – high temperature 600°C fission chambers CFUC – France.• TOKAMAK – TORE SUPRA – CFU, CPNB – France.

Applications and products : major NPP references worldwide

Photonis and future GenerationsPhotonis detector solutions are also present in safety-critical systems on many research reactors in France and Worldwide. Thanks to this strong link with research (CEA) and extensive operational experience on Generation II reactors, Photonis has developed instrumentation that fits for the challenges of Generation III (EPR) and IV (Astrid, HTR) reactors.

*ADS: Accelerated Driven Source*FBR: Fast Breeder Reactor

Page 6: Neutron & Gamma Detectors ASSURE YOUR SAFETY · 2- Neutron flux for RPS, fuel loading, reactivity meters, ex-core fission chamber and 10B proportional counter 3- Boron concentration

Photonis France SAS

Avenue Roger Roncier19100 Brive La GaillardeFrance

T +33 (0)555 86 38 26F +33 (0)555 86 37 79E [email protected] www.photonis.com

www.photonis.com

The information furnished is believed to be accurate and reliable, but is not guaranteed and is subject to change without notice. No liability is assumed by Photonis for its use. Performance data represents typical characteristics as individual product performance may vary. Customers should verify that they have the most current Photonis product information before placing orders. No claims or warranties are made as to the application of Photonis products. Pictures may not be considered as contractually binding. This document may not be reproduced, in whole or in part, without the prior written consent of Photonis.

NU

CL

EA

R-M

ay2

017