NetIQ ® AppManager ® for Nortel BCMx Management Guide February 2011

Transcript of NetIQ AppManager Nortel BCMx · Introducing AppManager for Nortel BCMx 1 Features and Benefits ......

Page 1: NetIQ AppManager Nortel BCMx · Introducing AppManager for Nortel BCMx 1 Features and Benefits ... • Nortel BCM alarms

NetIQ® AppManager® for Nortel™ BCMx

Management Guide

February 2011

Page 2: NetIQ AppManager Nortel BCMx · Introducing AppManager for Nortel BCMx 1 Features and Benefits ... • Nortel BCM alarms

Legal Notice

NetIQ AppManager is covered by United States Patent No(s): 05829001, 05986653, 05999178, 06078324, 06397359, 06408335.

THIS DOCUMENT AND THE SOFTWARE DESCRIBED IN THIS DOCUMENT ARE FURNISHED UNDER AND ARE SUBJECT TO THE TERMS OF A LICENSE AGREEMENT OR A NON-DISCLOSURE AGREEMENT. EXCEPT AS EXPRESSLY SET FORTH IN SUCH LICENSE AGREEMENT OR NON-DISCLOSURE AGREEMENT, NETIQ CORPORATION PROVIDES THIS DOCUMENT AND THE SOFTWARE DESCRIBED IN THIS DOCUMENT "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SOME STATES DO NOT ALLOW DISCLAIMERS OF EXPRESS OR IMPLIED WARRANTIES IN CERTAIN TRANSACTIONS; THEREFORE, THIS STATEMENT MAY NOT APPLY TO YOU.

This document and the software described in this document may not be lent, sold, or given away without the prior written permission of NetIQ Corporation, except as otherwise permitted by law. Except as expressly set forth in such license agreement or non-disclosure agreement, no part of this document or the software described in this document may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, or otherwise, without the prior written consent of NetIQ Corporation. Some companies, names, and data in this document are used for illustration purposes and may not represent real companies, individuals, or data.

This document could include technical inaccuracies or typographical errors. Changes are periodically made to the information herein. These changes may be incorporated in new editions of this document. NetIQ Corporation may make improvements in or changes to the software described in this document at any time.

© 2011 NetIQ Corporation. All rights reserved.

U.S. Government Restricted Rights: If the software and documentation are being acquired by or on behalf of the U.S. Government or by a U.S. Government prime contractor or subcontractor (at any tier), in accordance with 48 C.F.R. 227.7202-4 (for Department of Defense (DOD) acquisitions) and 48 C.F.R. 2.101 and 12.212 (for non-DOD acquisitions), the government’s rights in the software and documentation, including its rights to use, modify, reproduce, release, perform, display or disclose the software or documentation, will be subject in all respects to the commercial license rights and restrictions provided in the license agreement.

Check Point, FireWall-1, VPN-1, Provider-1, and SiteManager-1 are trademarks or registered trademarks of Check Point Software Technologies Ltd.

ActiveAudit, ActiveView, Aegis, AppManager, Change Administrator, Change Guardian, Compliance Suite, the cube logo design, Directory and Resource Administrator, Directory Security Administrator, Domain Migration Administrator, Exchange Administrator, File Security Administrator, Group Policy Administrator, Group Policy Guardian, Group Policy Suite, IntelliPolicy, Knowledge Scripts, NetConnect, NetIQ, the NetIQ logo, PSAudit, PSDetect, PSPasswordManager, PSSecure, Secure Configuration Manager, Security Administration Suite, Security Manager, Server Consolidator, VigilEnt, and Vivinet are trademarks or registered trademarks of NetIQ Corporation or its subsidiaries in the USA. All other company and product names mentioned are used only for identification purposes and may be trademarks or registered trademarks of their respective companies.

For purposes of clarity, any module, adapter or other similar material ("Module") is licensed under the terms and conditions of the End User License Agreement for the applicable version of the NetIQ product or software to which it relates or interoperates with, and by accessing, copying or using a Module you agree to be bound by such terms. If you do not agree to the terms of the End User License Agreement you are not authorized to use, access or copy a Module and you must destroy all copies of the Module and contact NetIQ for further instructions.

Page 3: NetIQ AppManager Nortel BCMx · Introducing AppManager for Nortel BCMx 1 Features and Benefits ... • Nortel BCM alarms

Contents

About this Book and the Library.................................................................................................................vAbout NetIQ Corporation ........................................................................................................................vii

Chapter 1Introducing AppManager for Nortel BCMx 1Features and Benefits..................................................................................................................................................1Counting AppManager Licenses ................................................................................................................................2Proxy Architecture ......................................................................................................................................................2Scalability Considerations ..........................................................................................................................................3

Chapter 2Installing AppManager for Nortel BCMx 5System Requirements..................................................................................................................................................5Installing the Module .................................................................................................................................................6Verifying Your Installed Module ................................................................................................................................7Upgrading Knowledge Script Jobs ..............................................................................................................................7Configuring the BCM User Name and Password ......................................................................................................8Scheduling BCM Maintenance ..................................................................................................................................9Troubleshooting Missing Data Points ........................................................................................................................9

Chapter 3NortelBCMx Knowledge Scripts 11Alarms .......................................................................................................................................................................12CallByCallLimits.......................................................................................................................................................15ChassisUsage.............................................................................................................................................................18HealthCheck .............................................................................................................................................................26HuntGroupUsage .....................................................................................................................................................30InterfaceHealth .........................................................................................................................................................32LinkUtilization..........................................................................................................................................................33LogicalDiskSpace ......................................................................................................................................................36PSTNFallback ...........................................................................................................................................................38QoSLog .....................................................................................................................................................................40SystemUpTime .........................................................................................................................................................44SystemUsage..............................................................................................................................................................45UPSHealth ................................................................................................................................................................47Recommended Knowledge Script Group ................................................................................................................50Discovery_NortelBCMx............................................................................................................................................51

Contents iii

Page 4: NetIQ AppManager Nortel BCMx · Introducing AppManager for Nortel BCMx 1 Features and Benefits ... • Nortel BCM alarms

iv Management Guide

Page 5: NetIQ AppManager Nortel BCMx · Introducing AppManager for Nortel BCMx 1 Features and Benefits ... • Nortel BCM alarms

About this Book and the Library

The NetIQ AppManager product (AppManager) is a comprehensive solution for managing, diagnosing, and analyzing performance, availability, and health for a broad spectrum of operating environments, applications, services, and server hardware.

AppManager provides system administrators with a central, easy-to-use console to view critical server and application resources across the enterprise. With AppManager, administrative staff can monitor computer and application resources, check for potential problems, initiate responsive actions, automate routine tasks, and gather performance data for real-time and historical reporting and analysis.

Intended AudienceThis guide provides information for individuals responsible for installing an AppManager module and monitoring specific applications with AppManager.

Other Information in the LibraryThe library provides the following information resources:

Installation Guide for AppManager

Provides complete information about AppManager pre-installation requirements and step-by-step installation procedures for all AppManager components.

User Guide for AppManager Control Center

Provides complete information about managing groups of computers, including running jobs, responding to events, creating reports, and working with Control Center. A separate guide is available for the AppManager Operator Console.

Administrator Guide for AppManager

Provides information about maintaining an AppManager management site, managing security, using scripts to handle AppManager tasks, and leveraging advanced configuration options.

Upgrade and Migration Guide for AppManager

Provides complete information about how to upgrade from a previous version of AppManager.

Management guides

Provide information about installing and monitoring specific applications with AppManager.

Help

Provides context-sensitive information and step-by-step guidance for common tasks, as well as definitions for each field on each window.

The AppManager library is available in Adobe Acrobat (PDF) format from the NetIQ Web site: www.netiq.com/support/am/extended/documentation/default.asp?version=AMDocumentation.

About this Book and the Library v

Page 6: NetIQ AppManager Nortel BCMx · Introducing AppManager for Nortel BCMx 1 Features and Benefits ... • Nortel BCM alarms

ConventionsThe library uses consistent conventions to help you identify items throughout the documentation. The following table summarizes these conventions.

Convention Use

Bold • Window and menu items

• Technical terms, when introduced

Italics • Book and CD-ROM titles

• Variable names and values

• Emphasized words

Fixed Font • File and folder names

• Commands and code examples

• Text you must type

• Text (output) displayed in the command-line interface

Brackets, such as [value] • Optional parameters of a command

Braces, such as {value} • Required parameters of a command

Logical OR, such as value1|value2

• Exclusive parameters. Choose one parameter.

vi Management Guide

Page 7: NetIQ AppManager Nortel BCMx · Introducing AppManager for Nortel BCMx 1 Features and Benefits ... • Nortel BCM alarms

About NetIQ Corporation

NetIQ, an Attachmate business, is a global leader in systems and security management. With more than 12,000 customers in over 60 countries, NetIQ solutions maximize technology investments and enable IT process improvements to achieve measureable cost savings. The company’s portfolio includes award-winning management products for IT Process Automation, Systems Management, Security Management, Configuration Audit and Control, Enterprise Administration, and Unified Communications Management. For more information, please visit www.netiq.com.

Contacting Sales SupportFor questions about products, pricing, and capabilities, please contact your local partner. If you cannot contact your partner, please contact our Sales Support team.

Contacting Technical SupportFor specific product issues, please contact our Technical Support team.

Contacting Documentation SupportOur goal is to provide documentation that meets your needs. If you have suggestions for improvements, please email [email protected]. We value your input and look forward to hearing from you.

Contacting the Online User CommunityQmunity, the NetIQ online community, is a collaborative network connecting you to your peers and NetIQ experts. By providing more immediate information, useful links to helpful resources, and access to NetIQ experts, Qmunity helps ensure you are mastering the knowledge you need to realize the full potential of IT investments upon which you rely. For more information, please visit http://community.netiq.com.

Worldwide: www.netiq.com/about_netiq/officelocations.asp

United States and Canada: 888-323-6768

Email: [email protected]

Web Site: www.netiq.com

Worldwide: www.netiq.com/Support/contactinfo.asp

North and South America: 1-713-418-5555

Europe, Middle East, and Africa: +353 (0) 91-782 677

Email: [email protected]

Web Site: www.netiq.com/support

About NetIQ Corporation vii

Page 8: NetIQ AppManager Nortel BCMx · Introducing AppManager for Nortel BCMx 1 Features and Benefits ... • Nortel BCM alarms

viii Management Guide

Page 9: NetIQ AppManager Nortel BCMx · Introducing AppManager for Nortel BCMx 1 Features and Benefits ... • Nortel BCM alarms

Chapter 1

Introducing AppManager for Nortel BCMx

This chapter introduces AppManager for Nortel Business Communications Manager (Nortel BCMx), providing a brief overview of the module’s architecture and describing how you can use AppManager to better monitor vital BCM resources.

Please note that in this document, the term BCMx refers to the AppManager module, and the term BCM refers to all supported versions of BCM. If a discussion relates only to a specific supported version, the appropriate version number is used to reference the BCM model or software in question.

Features and Benefits

AppManager is designed to help you gain easy access to BCM data, and to help you analyze and manage that data. The AppManager for Nortel BCMx solution minimizes the cost of maintaining BCM services and functions, aids in capacity planning, and can prevent downtime.

With AppManager for Nortel BCMx, administrators gain access to a new set of tools they can leverage to gather a wide range of diagnostic and management data, which can help prevent outages and keep things running smoothly.

AppManager for Nortel BCMx includes Knowledge Scripts for creating jobs that monitor the health, availability, and performance of key BCM features. These scripts allow you to monitor and manage crucial services at a depth unparalleled by any other solution. Each Knowledge Script can be configured to raise an event, collect data for reporting, and perform automated problem management when an event occurs.

The following are just a few of the features and benefits of monitoring Nortel BCM with AppManager:

• BCMs and associated components are discovered with a single discovery job

• Knowledge Scripts collect data for all monitored BCMs and associated components:

• System health, including CPU, memory, disk space, and temperature

• BCM availability

• BCM link utilization for LAN links

• BCM QoS log entries for MOS estimates for several codecs: G.711a, G.711u, G.723.1 (5.3 and 6.3 kbps), G.729, and G.729A

• Hunt group usage, including abandoned calls

• Nortel BCM alarms

• Limited support for SRG (Survivable Remote Gateway) mode and local mode with the Alarms, CallByCallLimits, ChassisUsage, HealthCheck, HuntGroupUsage, InterfaceHealth, LinkUtilization, PSTNFallback, SystemUpTime, and SystemUsage Knowledge Scripts

Chapter 1 • Introducing AppManager for Nortel BCMx 1

Page 10: NetIQ AppManager Nortel BCMx · Introducing AppManager for Nortel BCMx 1 Features and Benefits ... • Nortel BCM alarms

Counting AppManager Licenses

AppManager for Nortel BCMx consumes one AppManager license per phone registered to a BCM.

Proxy Architecture

With AppManager proxy architecture support for Nortel BCM, the AppManager agent does not need to be installed on every device that you want to monitor.

Within the proxy architecture, the AppManager for Nortel BCMx managed object (qNortelBCMx.dll) is installed on the managed client (agent) computer. When you run a Knowledge Script job, the BCMx managed object runs on the managed client and sends messages to and from BCM devices (using CIM/XML) for which you have designated the managed client computer as the proxy.

The following drawing shows the relationship between Nortel BCM devices and the AppManager server and proxy agent computers.

2 Management Guide

Page 11: NetIQ AppManager Nortel BCMx · Introducing AppManager for Nortel BCMx 1 Features and Benefits ... • Nortel BCM alarms

Scalability Considerations

Only one computer should act as a proxy for any given Nortel BCM device. One computer should be the proxy for no more than 100 Nortel BCM devices. Of course, this number is only a recommendation and can vary based on the capabilities of your proxy computer.

As you scale up your Nortel BCM environment, consider the following:

• The HealthCheck Knowledge Script requires extensive use of the proxy computer’s processing capacity. Because this script is a member of the NortelBCMx Recommended Knowledge Script Group (KSG), running it may affect the performance of other recommended scripts that are running at the same time.

• The LogicalDiskSpace Knowledge Script is a member of the NortelBCMx Recommended KSG, which allows you to run all recommended scripts at one time. However, there are limits on the number of Logical Disk objects on which the LogicalDiskSpace script can run. If you run the Recommended KSG on more objects than the LogicalDiskSpace script allows, you will receive an error message indicating that the number of target objects has exceeded its limit. If you receive this error message, remove the LogicalDiskSpace script from the KSG. Then run LogicalDiskSpace alone on fewer Logical Disk objects.

Chapter 1 • Introducing AppManager for Nortel BCMx 3

Page 12: NetIQ AppManager Nortel BCMx · Introducing AppManager for Nortel BCMx 1 Features and Benefits ... • Nortel BCM alarms

4 Management Guide

Page 13: NetIQ AppManager Nortel BCMx · Introducing AppManager for Nortel BCMx 1 Features and Benefits ... • Nortel BCM alarms

Chapter 2

Installing AppManager for Nortel BCMx

This chapter provides installation instructions and describes system requirements for AppManager for Nortel BCMx.

This chapter assumes you have AppManager installed. For more information about installing AppManager or about AppManager system requirements, see the Installation Guide for AppManager, which is available on the NetIQ Web site or in the \Documentation folder of the AppManager installation kit.

System Requirements

AppManager for NortelBCMx has the following system requirements:

For the latest information about supported software versions and the availability of module updates, visit the AppManager Supported Products page at www.netiq.com/support/am/supportedproducts/default.asp. If you encounter problems using this module with a later version of your application, contact NetIQ Technical Support.

For more information about system requirements for the AppManager agent, repository, and management server, see the Installation Guide for AppManager.

Software/Hardware Version

NetIQ AppManager installed on the AppManager repository (QDB), console, and proxy agent computer

At minimum, 7.0

Support for Windows Server 2008 requires hotfix 71704, or the most recent AppManager Windows Agent hotfix. For more information, see the AppManager Suite Hotfixes Web page.

Nortel BCM software installed on the BCM hardware you want to monitor

4.0 on BCM 200, 400, or 1000

1.0, 5.0 on BCM 450

1.0, 3.0, 5.0 on BCM 50 (firmware releases 1.00.2.04.j through 3.0), including versions 50a (with an ADSL router) and 50e (with an Ethernet router)

Nortel BCM patch installed on the BCM hardware you want to monitor

BCM.R400.032-PSM installed on BCM software version 4.0. NetIQ does not guarantee the CPU and memory data returned by the SystemUsage Knowledge Script if patch BCM.R400.032-PSM is not installed.

Microsoft operating system installed on the proxy agent computer

One of the following:

• 32-bit Windows 2000

• 32- or 64-bit Windows Server 2003

• 32- or 64-bit Windows Server 2008

• Windows Server 2008 R2

Chapter 2 • Installing AppManager for Nortel BCMx 5

Page 14: NetIQ AppManager Nortel BCMx · Introducing AppManager for Nortel BCMx 1 Features and Benefits ... • Nortel BCM alarms

Installing the Module

The setup program automatically identifies and updates all relevant AppManager components on a computer. Therefore, run the setup program only once on any computer. The pre-installation check also runs automatically when you launch the setup program.

You can install the module in one of the following ways:

• Run the module setup program, AM70-NortelBCMx-7.x.x.0.msi, which you downloaded from the Web. Save the module setup files on the distribution computer, and then delete the older versions of the module setup files. For more information about the distribution computer, see the Installation Guide for AppManager.

• Use Control Center to install the module on the remote computer where an agent is installed. Ensure you check in the installation package, which is the .XML file included with the module setup program. For more information about the .XML file, see the AppManager for NortelBCMx Readme. For more information about deploying modules on agent computers, see the Control Center User Guide for AppManager.

To install the module:

1. Run the module setup program on all repository computers to install the Knowledge Scripts and reports. For repositories running in a clustered environment, run the setup program on the node that currently owns the cluster resource.

2. Install the module on each proxy agent computer. Use one of the following methods:

• Run the module setup program.

• Use Control Center Console to deploy the installation package.

3. Run the module setup program on all Operator Console and Control Center computers to install the Help.

4. Configure the user name and password for the BCM devices into AppManager Security Manager. For more information, see “Configuring the BCM User Name and Password” on page 8.

5. If you have not already discovered Nortel BCMx resources, run the Discovery_NortelBCMx Knowledge Script on the proxy agent computers where you installed the module.

After the installation has completed, you can find a record of problems encountered in the NortelBCMx_Install.log file, located in the \NetIQ\Temp\NetIQ_Debug\<ServerName> folder.

NoteNo other AppManager module should be installed on the proxy agent computer.

6 Management Guide

Page 15: NetIQ AppManager Nortel BCMx · Introducing AppManager for Nortel BCMx 1 Features and Benefits ... • Nortel BCM alarms

Verifying Your Installed Module

To verify installation on many computers, run the ReportAM_CompVersion Knowledge Script. Ensure you discover a report-enabled agent before running this script. For more information, see the Help for the script.

To verify installation on one or only a few computers, use the Operator Console.

To verify your installed module with the Operator Console:

1. In the TreeView pane, select the computer for which you want to verify your installed module.

2. From the TreeView menu, select Properties. On the System tab, the System information pane displays the version numbers for all modules installed on the computer.

3. Verify that the version number from the AppManager for Nortel BCMx Readme matches the version number shown in the System information pane.

Upgrading Knowledge Script Jobs

This release of AppManager for Nortel BCMx may contain updated Knowledge Scripts. You can push the changes for updated scripts to running Knowledge Script jobs in one of the following ways:

• Use the AMAdmin_UpgradeJobs Knowledge Script.

• Use the Properties Propagation feature.

Running AMAdmin_UpgradeJobsThe AMAdmin_UpgradeJobs Knowledge Script can push changes to running Knowledge Script jobs. Your AppManager repository (QDB) must be at version 7.0 or later. In addition, the repository computer must have hotfix 72040 installed, or the most recent AppManager Repository hotfix. To download the hotfix, see the AppManager Suite Hotfixes Web page.

Upgrading jobs to use the most recent script version allows the jobs to take advantage of the latest script logic while maintaining existing parameter values for the job.

For more information, see the Help for the AMAdmin_UpgradeJobs Knowledge Script.

Propagating Knowledge Script ChangesYou can propagate script changes to jobs that are running and to Knowledge Script Groups, including recommended Knowledge Script Groups and renamed Knowledge Scripts.

Before propagating script changes, verify that the script parameters are set to your specifications. Customized script parameters may have reverted to default parameters during the installation of the module. New parameters may need to be set appropriately for your environment or application.

You can choose to propagate only properties (specified in the Schedule and Values tabs), only the script (which is the logic of the Knowledge Script), or both. Unless you know specifically that changes affect only the script logic, you should propagate both properties and the script.

For more information about propagating Knowledge Script changes, see the “Running Monitoring Jobs” chapter of the Operator Console User Guide for AppManager.

Chapter 2 • Installing AppManager for Nortel BCMx 7

Page 16: NetIQ AppManager Nortel BCMx · Introducing AppManager for Nortel BCMx 1 Features and Benefits ... • Nortel BCM alarms

Propagating Changes to Ad Hoc Jobs

You can propagate the properties and the logic (script) of a Knowledge Script to ad hoc jobs started by that Knowledge Script. Corresponding jobs are stopped and restarted with the Knowledge Script changes.

To propagate changes to ad hoc Knowledge Script jobs:

1. In the Knowledge Script view, select the Knowledge Script for which you want to propagate changes.

2. Click Properties Propagation > Ad Hoc Jobs.

3. Select the components of the Knowledge Script that you want to propagate to associated ad hoc jobs:

Propagating Changes to Knowledge Script Groups

You can propagate the properties and logic (script) of a Knowledge Script to corresponding Knowledge Script Group members.

After you propagate script changes to Knowledge Script Group members, you can propagate the updated Knowledge Script Group members to associated running jobs. For more information, see “Propagating Changes to Ad Hoc Jobs” on page 8.

To propagate Knowledge Script changes to Knowledge Script Groups:

1. In the Knowledge Script view, select the Knowledge Script Group for which you want to propagate changes.

2. On the KS menu, select Properties propagation > Ad Hoc Jobs.

3. If you want to exclude a Knowledge Script member from properties propagation, deselect that member from the list in the Properties Propagation dialog box.

4. Select the components of the Knowledge Script that you want to propagate to associated Knowledge Script Groups:

5. Click OK. Any monitoring jobs started by a Knowledge Script Group member are restarted with the job properties of the Knowledge Script Group member.

Configuring the BCM User Name and Password

AppManager cannot communicate with Nortel BCM devices unless it has permission to do so. You can grant that permission by configuring the appropriate user name and password into AppManager Security Manager.

Select To propagate

Script The logic of the Knowledge Script.

Properties Values from the Knowledge Script Schedule and Values tabs, such as schedule, monitoring values, actions, and advanced options.

Select To propagate

Script The logic of the Knowledge Script.

Properties Values from the Knowledge Script Schedule and Values tabs, including the schedule, actions, and Advanced properties.

8 Management Guide

Page 17: NetIQ AppManager Nortel BCMx · Introducing AppManager for Nortel BCMx 1 Features and Benefits ... • Nortel BCM alarms

Configure Security Manager before you run Discovery_NortelBCMx. Without knowing the user name and password, the discovery process cannot locate your BCM devices.

If you need to create a new user for the BCM, see the “Security Policies and Accounts and Privileges” chapter of the Administration Guide for your BCM device.

On the Custom tab in Security Manager, complete the following fields:

Scheduling BCM Maintenance

Use the AMAdmin_SchedMaint Knowledge Script to specify a maintenance period for a BCM device. During the maintenance period, regularly scheduled AppManager jobs can be prevented from running. Set the maintenance periods to coincide with those times that you are performing scheduled backups of your BCM device.

You can specify the type of Knowledge Scripts you want to block by Knowledge Script category, or prevent all jobs from running on a server (because of expected downtime, for example).

For more information about setting up AMAdmin_SchedMaint, see the Help for the script.

For more information about performing backups of your BCM device, see the Administration Guide for your BCM device.

Troubleshooting Missing Data Points

AppManager for NortelBCMx sends consolidated requests to the Nortel BCM device in order to efficiently collect the data used by all NortelBCMx Knowledge Scripts (except Alarms and Discovery). AppManager sends these requests 30 seconds before a Knowledge Script begins each iteration. This 30-second data-collection offset allows enough time for AppManager to execute the query before a Knowledge Script requires the data.

If you notice that data points are missing from a job’s data stream, it may be that 30 seconds is not enough time for AppManager to execute all of the queries you need, most likely because you are running several scripts on the same schedule.

You can increase the data-collection offset time by changing a Registry setting:

HKEY_LOCAL_MACHINE\SOFTWARE\NetIQ\Appmanager\4.0\NetIQmc\DataRecorder\CollectionOffset

Field Description

Label NortelBCMx

Sub-label default

Value 1 Case-sensitive user name

Value 2 Case-sensitive password

Extended application support Encrypts the user name and password in Security Manager. Do not leave this option unselected.

Chapter 2 • Installing AppManager for Nortel BCMx 9

Page 18: NetIQ AppManager Nortel BCMx · Introducing AppManager for Nortel BCMx 1 Features and Benefits ... • Nortel BCM alarms

In the right pane of the Registry Editor, double-click NortelBCMx and change the Decimal value from 30 seconds to a larger value that will allow enough time for AppManager to execute the queries for all of the scripts you are running. Keep the value less than the shortest interval specified by any Knowledge Script. For example, if one script runs every one minute, but the others run every five minutes, do not change the Registry setting to a value equal to or greater than 60 seconds.

Notes• Changes to this Registry setting affect the data-collection offset time for every NortelBCMx

Knowledge Script, except Alarms and Discovery_NortelBCMx.

• If you change a Registry setting, you must restart the NetIQ AppManager Client Resource Monitor service (netiqmc.exe) before the new value is in effect.

10 Management Guide

Page 19: NetIQ AppManager Nortel BCMx · Introducing AppManager for Nortel BCMx 1 Features and Benefits ... • Nortel BCM alarms

Chapter 3

NortelBCMx Knowledge Scripts

AppManager for Nortel BCMx provides the following Knowledge Scripts for monitoring Nortel BCM software version 4.0 or later on hardware models 200, 400 and 1000, and Nortel BCM firmware version 1.00.2.04j or greater on hardware model 50, including versions 50a and 50e. From within the Operator Console, select a Knowledge Script on the NortelBCMx tab in the Knowledge Script pane and press F1 for complete details.

Knowledge Script What It Does

Alarms Monitors the Nortel BCMx proxy computer for Nortel BCM alarms.

CallByCallLimits Monitors the number of incoming and outgoing calls denied because call-by-call limits were exceeded.

ChassisUsage Monitors the physical chassis of a BCM device.

HealthCheck Monitors the operational status of BCM services.

HuntGroupUsage Monitors call statistics for one or more hunt groups.

InterfaceHealth Monitors the operational status of the interfaces on a network device.

LinkUtilization Monitors LAN links for utilization and packet errors.

LogicalDiskSpace Monitors logical disk space usage and availability.

PSTNFallback Monitors PSTN fallback attempts and failures.

QoSLog Monitors the MOS estimates for several codecs: G.711a, G.711u, G.723 5.3. kbps, G.723 6.3 kbps, G.729, and G.729A.

SystemUpTime Monitors the number of seconds that the system has been operational since its last reboot.

SystemUsage Monitors BCM CPU and memory usage.

UPSHealth Monitors any attached uninterruptible power supply.

Recommended Knowledge Script Group

Performs essential monitoring of your Nortel BCM environment.

Discovery_NortelBCMx Discovers the various components of a Nortel BCM installation for software version 4.0 and hardware models 50, 50a, 50e, 200, 400, and 1000.

Chapter 3 • NortelBCMx Knowledge Scripts 11

Page 20: NetIQ AppManager Nortel BCMx · Introducing AppManager for Nortel BCMx 1 Features and Benefits ... • Nortel BCM alarms

AlarmsUse this Knowledge Script to monitor the Nortel BCMx proxy computer for Nortel BCM alarms. Nortel BCM devices send alarms to the proxy computer using SNMP traps.

When setting parameters for this script, you are asked to provide a list of alarm identifiers (system messages) that you want to include or exclude from monitoring. Their format consists of a multi-digit alarm number, such as 18 or 10029.

Prerequisites• Install the Windows SNMP service before running this script. If you installed the service before you

installed the Nortel BCMx module that contains this script, you do not need to do anything else. If you installed the service after you installed the Nortel BCMx module, stop and restart the AppManager agent on the proxy agent computer before using this script.

• Configure Nortel BCM devices to send SNMP traps to the proxy agent. For more information, see “Identifying the SNMP Trap Receiver” on page 14.

Monitoring in SRG ModeThis script supports BCM 50 hardware running Nortel Survivable Remote Gateway (SRG) software, including instances when the SRG shifts to local mode for any reason.

Resource ObjectNortel_BCMx

Default ScheduleBy default, this script runs on an asynchronous schedule.

Setting Parameter ValuesSet the following parameters as needed.

Parameter How to Set It

Notes for the alarm categories:

• If you choose to “Include only” selected alarm identifiers in a category, AppManager will raise events only for those identifiers. AppManager will not raise events for the other identifiers included in the category.

• If you choose to “Exclude” selected alarm identifiers from a category, AppManager will raise events for all alarm identifiers included in the category except those that you specifically excluded.

• If you accept the default parameter settings, which are “Exclude” and blank (in the Alarm identifiers parameter), AppManager will raise events for all identifiers in the category, because you excluded nothing from the category.

Monitor PVQM alarms? Select Yes to monitor the Nortel BCMx proxy server for alarms in the “PVQM” category. The default is Yes.

Include or exclude alarms? Select whether you want to Include only or Exclude the alarm identifiers that you specify in the following parameter.

By default, AppManager monitors all alarms with PVQM severity in the SNMP trap.

12 Management Guide

Page 21: NetIQ AppManager Nortel BCMx · Introducing AppManager for Nortel BCMx 1 Features and Benefits ... • Nortel BCM alarms

Alarm identifiers Provide a comma-separated list of the alarm identifiers you want to include in or exclude from the “PVQM” category. By default, the list contains the 50501, 50504, 50507, and 50510 identifiers.

Monitor critical alarms? Select Yes to monitor the Nortel BCMx proxy server for alarms in the “critical” category. The default is Yes.

Include or exclude alarms? Select whether you want to Include only or Exclude the alarm identifiers you specify in the following parameter.

By default, AppManager monitors all alarms with critical severity in the SNMP trap.

Alarm identifiers Provide a comma-separated list of the alarm identifiers you want to include in or exclude from the “critical” category. The default is an empty list.

Monitor major alarms? Select Yes to monitor the Nortel BCMx proxy server for alarms in the “major” category. The default is unselected.

Include or exclude alarms? Select whether you want to Include only or Exclude the alarm identifiers you specify in the following parameter.

By default, AppManager monitors all alarms with major severity in the SNMP trap.

Alarm identifiers Provide a comma-separated list of the alarm identifiers you want to include in or exclude from the “major” category. The default is an empty list.

Monitor minor alarms? Select Yes to monitor the Nortel BCMx proxy server for alarms in the “minor” category. The default is unselected.

Include or exclude alarms? Select whether you want to Include only or Exclude the alarm identifiers you specify in the following parameter.

By default, AppManager monitors all alarms with minor severity in the SNMP trap.

Alarm identifiers Provide a comma-separated list of the alarm identifiers you want to include in or exclude from the “minor” category. The default is an empty list.

Monitor warning alarms? Select Yes to monitor the Nortel BCMx proxy server for alarms in the “warning” category. The default is unselected.

Include or exclude alarms? Select whether you want to Include only or Exclude the alarm identifiers you specify in the following parameter.

By default, AppManager monitors all alarms with warning severity in the SNMP trap.

Alarm identifiers Provide a comma-separated list of the alarm identifiers you want to include in or exclude from the “warning” category. The default is an empty list.

Monitor info alarms? Select Yes to monitor the Nortel BCMx proxy server for alarms in the “informational” category. The default is unselected.

Include or exclude alarms? Select whether you want to Include only or Exclude the alarm identifiers you specify in the following parameter.

By default, AppManager monitors all alarms with informational severity in the SNMP trap.

Alarm identifiers Provide a comma-separated list of the alarm identifiers you want to include in or exclude from the “informational” category. The default is an empty list.

Event Severities

Severity - Critical alarms Set the severity level, between 1 and 40, to indicate the importance of an event in which a critical alarm is detected. The default is 10.

Severity - Major alarms Set the severity level, between 1 and 40, to indicate the importance of an event in which a major alarm is detected. The default is 15.

Severity - Minor alarms Set the severity level, between 1 and 40, to indicate the importance of an event in which a minor alarm is detected. The default is 20.

Parameter How to Set It

Chapter 3 • NortelBCMx Knowledge Scripts 13

Page 22: NetIQ AppManager Nortel BCMx · Introducing AppManager for Nortel BCMx 1 Features and Benefits ... • Nortel BCM alarms

Identifying the SNMP Trap ReceiverManually configure Nortel BCM to send SNMP traps to AppManager. Use Element Manager to identify the AppManager proxy computer as an SNMP trap receiver.

To identify the proxy computer as a trap receiver:

1. Log in to Element Manager.

2. On the Administration tab, expand the General folder and select SNMP Trap Destinations.

3. In the right pane, click Add, and then complete the fields as described in the table below:

4. Click OK.

Severity - Warning alarms Set the severity level, between 1 and 40, to indicate the importance of an event in which a warning alarm is detected. The default is 25.

Severity - Info alarms Set the severity level, between 1 and 40, to indicate the importance of an event in which an informational alarm is detected. The default is 30.

Field Instructions

Name Provide the host name of the proxy agent computer to which you want to send SNMP traps (the computer on which the BCMx module is installed).

Host address Provide the IP address of the proxy agent computer.

Port Accept the default: port 162.

SNMP version Accept the default: v1/v2C.

Community string Provide the SNMP community string of the proxy agent computer.

User name Leave this field blank.

Parameter How to Set It

14 Management Guide

Page 23: NetIQ AppManager Nortel BCMx · Introducing AppManager for Nortel BCMx 1 Features and Benefits ... • Nortel BCM alarms

CallByCallLimitsUse this Knowledge Script to monitor incoming and outgoing calls that were denied because call-by-call limits were exceeded. PRI pools that support call-by-call services have maximum and minimum call limits for each service. You can assess the capacity of the PRI call services on your system by monitoring the number of calls that were denied because they exceeded or fell below the limits.

This script raises an event when any monitored value exceeds a threshold that you set.

Call-by-call limits are programmed in Element Manager and are defined as follows:

Monitoring in SRG ModeThis script supports BCM 50 hardware running Nortel Survivable Remote Gateway (SRG) software, including instances when the SRG shifts to local mode for any reason.

Resource ObjectNortel_BCMx_PRIPool

Default ScheduleThe default interval for this script is five minutes.

Setting Parameter ValuesSet the following parameters as needed.

Limit Definition

Incoming maximum The maximum number of calls that can enter the PRI pools for a particular service. Any calls that exceed the maximum will be denied.

Incoming minimum The minimum number of calls that can enter the PRI pools for a particular service. If the number of calls falls below the minimum, the calls will be denied and the PRI pools will be allocated to a different service.

Outgoing maximum The maximum number of calls that can exit the PRI pools for a particular service. Any calls that exceed the maximum will be denied.

Outgoing minimum The minimum number of calls that can exit the PRI pools for a particular service. If the number of calls falls below the minimum, the calls will be denied and the PRI pools will be allocated to a different service.

Parameter How To Set It

General Settings

Job Failure Notification

Event severity when job fails Set the severity level, from 1 to 40, to indicate the importance of an event raised when the CallByCallLimits job fails. The default is 5.

Monitor incoming calls denied after maximum limit exceeded

Event Notification

Chapter 3 • NortelBCMx Knowledge Scripts 15

Page 24: NetIQ AppManager Nortel BCMx · Introducing AppManager for Nortel BCMx 1 Features and Benefits ... • Nortel BCM alarms

Raise event if denied incoming calls exceed threshold?

Select Yes to raise an event if the number of denied incoming calls exceeds the threshold that you set. The default is Yes.

Threshold - Maximum denied incoming calls

Specify the highest number of incoming calls that can be denied before an event is raised. The default is 0 calls.

Event severity when denied incoming calls exceed threshold

Set the severity level, from 1 to 40, to indicate the importance of an event in which the number of denied incoming calls exceeds the threshold. The default is 10.

Data Collection

Collect data for incoming calls denied after maximum limit exceeded?

Select Yes to collect data about incoming calls that were denied after the maximum limit was exceeded. The default is unselected.

Monitor incoming calls denied after minimum limit not reached

Event Notification

Raise event if denied incoming calls exceed threshold?

Select Yes to raise an event if the number of denied incoming calls exceeds the threshold that you set. The default is Yes.

Threshold - Maximum denied incoming calls

Specify the maximum number of incoming calls that can be denied before an event is raised. The default is 0 calls.

Event severity when denied incoming calls exceed threshold

Set the severity level, from 1 to 40, to indicate the importance of an event in which the number of denied incoming calls exceeds the threshold. The default is 10.

Data Collection

Collect data for incoming calls denied after minimum limit not reached

Select Yes to collect data about incoming calls that were denied after the minimum limit was not reached. The default is unselected.

Monitor outgoing calls denied after maximum limit exceeded

Event Notification

Raise event if denied outgoing calls exceed threshold?

Select Yes to raise an event if the number of denied outgoing calls exceeds the threshold that you set. The default is Yes.

Threshold - Maximum denied outgoing calls

Specify the highest number of outgoing calls that can be denied before an event is raised. The default is 0 calls.

Event severity when denied outgoing calls exceed threshold

Set the severity level, from 1 to 40, to indicate the importance of an event in which the number of denied outgoing calls exceeds the threshold. The default is 10.

Data Collection

Collect data for outgoing calls denied after maximum limit exceeded?

Select Yes to collect data about outgoing calls that were denied after the maximum limit was exceeded. The default is unselected.

Monitor outgoing calls denied after minimum limit not reached

Event Notification

Raise event if denied outgoing calls exceed threshold?

Select Yes to raise an event if the number of denied outgoing calls exceeds the threshold that you set. The default is Yes.

Parameter How To Set It

16 Management Guide

Page 25: NetIQ AppManager Nortel BCMx · Introducing AppManager for Nortel BCMx 1 Features and Benefits ... • Nortel BCM alarms

Threshold - Maximum denied outgoing calls

Specify the highest number of outgoing calls that can be denied before an event is raised. The default is 0 calls.

Event severity when denied outgoing calls exceed threshold

Set the severity level, from 1 to 40, to indicate the importance of an event in which the number of denied outgoing calls exceeds the threshold. The default is 10.

Data Collection

Collect data for outgoing calls denied after minimum limit not reached?

Select Yes to collect data about outgoing calls that were denied after the minimum limit was not reached. The default is unselected.

Parameter How To Set It

Chapter 3 • NortelBCMx Knowledge Scripts 17

Page 26: NetIQ AppManager Nortel BCMx · Introducing AppManager for Nortel BCMx 1 Features and Benefits ... • Nortel BCM alarms

ChassisUsageUse this Knowledge Script to monitor the physical chassis of a BCM device, including temperature sensors, voltage sensors, and fan speeds. This script raises events for status changes in BCM 200/400 components (running BCM software version 4.0) and for monitored values that exceed or fall below the threshold that you set. In addition, this script generates data streams for the following metrics:

• Remote temperature for BCM 50

• Local temperature

• CPU temperature for BCM 200/400

• Fan 1 and fan 2 speeds for BCM 50

• Power supply voltage levels:

• v5

• v+12

• v-12 for BCM 200/400

• vcc for BCM 50

• vccp for BCM 50

• v3.3 (Standby, One, and Two) for BCM 200/400

Monitoring in SRG ModeThis script supports BCM 50 hardware running Nortel Survivable Remote Gateway (SRG) software, including instances when the SRG shifts to local mode for any reason.

Resource ObjectNortel_BCMx

Default ScheduleThe default interval for this script is five minutes.

Notes• BCM model 1000 does not support the monitoring of voltage, fan speed, or temperature. This script

raises an event if you attempt to monitor any of these chassis components on BCM 1000.

• In this script, the monitoring of fan speeds, temperatures, and voltages is disabled by default. BCM itself will raise an alarm if any of these values is abnormal, and then send the alarm as an SNMP trap to the Alarms script. If you enable the monitoring of fan speeds, temperatures, or voltages, be aware that you may receive duplicate or conflicting alarm and events. For instance, AppManager may raise an event indicating a high temperature based on a threshold that you set, but the BCM does not raise an alarm because the temperature has not yet reached the abnormal level as determined by Nortel.

18 Management Guide

Page 27: NetIQ AppManager Nortel BCMx · Introducing AppManager for Nortel BCMx 1 Features and Benefits ... • Nortel BCM alarms

Setting Parameter ValuesSet the following parameters as needed.

Description How To Set It

General Settings

Job Failure Notification

Event severity when job fails Set the severity level, from 1 to 40, to indicate the importance of an event raised when the ChassisUsage job fails. The default is 5.

The ChassisUsage script monitors status changes only for BCM 200/400 models running BCM software version 4.0. The event message indicates the type of change, such as “The status for local temperature has changed to Above Tolerance” or “The status of fan 1 has changed to Stopped.”

Raise event if local temperature status changes?

Select Yes to raise an event if the status of the local temperature changes. The default is unselected.

Event severity when local temperature status changes

Set the severity level, from 1 to 40, to indicate the importance of an event in which the status of the local temperature has changed. The default is 30.

Raise event if CPU temperature status changes?

Select Yes to raise an event if the status of the CPU temperature changes. The default is unselected.

Event severity when CPU temperature status changes

Set the severity level, from 1 to 40, to indicate the importance of an event in which the status of the CPU temperature has changed. The default is 30.

Raise event if fan 1 status changes?

Select Yes to raise an event if the status of fan 1 changes. The default is unselected.

Event severity when fan 1 status changes

Set the severity level, from 1 to 40, to indicate the importance of an event in which the status of fan 1 has changed. The default is 30.

Raise event if CPU fan status changes?

Select Yes to raise an event if the status of the CPU fan changes. The default is unselected.

Event severity when CPU fan status changes

Set the severity level, from 1 to 40, to indicate the importance of an event in which the status of the CPU fan has changed. The default is 30.

Raise event if v5 voltage status changes?

Select Yes to raise an event if the status of the v5 power supply voltage changes. The default is unselected.

Event severity when v5 voltage status changes

Set the severity level, from 1 to 40, to indicate the importance of an event in which the status of the v5 power supply voltage has changed. The default is 30.

Raise event if v+12 voltage status changes?

Select Yes to raise an event if the status of the v+12 power supply voltage changes. The default is unselected.

Event severity when v+12 voltage status changes

Set the severity level, from 1 to 40, to indicate the importance of an event in which the status of the v+12 power supply voltage has changed. The default is 30.

Raise event if v-12 voltage status changes?

Select Yes to raise an event if the status of the v-12 power supply voltage changes. The default is unselected.

Event severity when v-12 voltage status changes

Set the severity level, from 1 to 40, to indicate the importance of an event in which the status of the v-12 power supply voltage has changed. The default is 30.

Raise event if v3.3 Standby voltage status changes?

Select Yes to raise an event if the status of the v3.3 Standby power supply voltage changes. The default is unselected.

Event severity when v3.3 Standby voltage status changes

Set the severity level, from 1 to 40, to indicate the importance of an event in which the status of the v3.3 Standby power supply voltage has changed. The default is 30.

Chapter 3 • NortelBCMx Knowledge Scripts 19

Page 28: NetIQ AppManager Nortel BCMx · Introducing AppManager for Nortel BCMx 1 Features and Benefits ... • Nortel BCM alarms

Raise event if v3.3 One voltage status changes?

Select Yes to raise an event if the status of the v3.3 One power supply voltage changes. The default is unselected.

Event severity when v3.3 One voltage status changes

Set the severity level, from 1 to 40, to indicate the importance of an event in which the status of the v3.3 One power supply voltage has changed. The default is 30.

Raise event if v3.3 Two voltage status changes?

Select Yes to raise an event if the status of the v3.3 Two power supply voltage changes. The default is unselected.

Event severity when v3.3 Two voltage status changes

Set the severity level, from 1 to 40, to indicate the importance of an event in which the status of the v3.3 Two power supply voltage has changed. The default is 30.

Monitor local temperature

Event Notification

Raise event if local temperature exceeds threshold?

Select Yes to raise an event if the local temperature exceeds the threshold that you set. The default is unselected.

Threshold - Maximum local temperature

Specify the highest local temperature that can occur before an event is raised. The default is 55º Celsius.

Event severity when local temperature exceeds threshold

Set the severity level, from 1 to 40, to indicate the importance of an event in which the local temperature exceeds the threshold. The default is 10.

Data Collection

Collect data for local temperature?

Select Yes to collect data about local temperature for reports and graphs. The default is unselected.

Monitor remote temperature (BCM 50 only)

Event Notification

Raise event if remote temperature exceeds threshold?

Select Yes to raise an event if the remote temperature on a BCM 50 exceeds the threshold that you set. The default is unselected.

Threshold - Maximum remote temperature

Specify the highest remote temperature that can occur on a BCM 50 before an event is raised. The default is 55º Celsius.

Event severity when remote temperature exceeds threshold

Set the severity level, from 1 to 40, to indicate the importance of an event in which the remote temperature on a BCM 50 exceeds the threshold. The default is 10.

Data Collection

Collect data for remote temperature?

Select Yes to collect data about remote temperature for reports and graphs. The default is unselected.

Monitor CPU temperature (BCM 200/400 only)

Event Notification

Raise event if CPU temperature exceeds threshold?

Select Yes to raise an event if the CPU temperature on a BCM 200 or 400 exceeds the threshold that you set. The default is unselected.

Threshold - Maximum CPU temperature

Specify the highest CPU temperature that can occur on a BCM 200 or 400 before an event is raised. The default is 55º Celsius.

Event severity when CPU temperature exceeds threshold

Set the severity level, from 1 to 40, to indicate the importance of an event in which the CPU temperature on a BCM 200 or 400 exceeds the threshold. The default is 10.

Data Collection

Description How To Set It

20 Management Guide

Page 29: NetIQ AppManager Nortel BCMx · Introducing AppManager for Nortel BCMx 1 Features and Benefits ... • Nortel BCM alarms

Collect data for CPU temperature?

Select Yes to collect data about CPU temperature for reports and graphs. The default is unselected.

Monitor fan 1 speed (BCM 50 only)

Event Notification

Raise event if fan 1 speed exceeds threshold?

Select Yes to raise an event if the speed of fan 1 on a BCM 50 exceeds the threshold that you set. The default is unselected.

Threshold - Maximum fan 1 speed

Specify the highest fan speed that can occur before an event is raised. The default is 10000 RPMs.

Event severity when fan 1 speed exceeds threshold

Set the severity level, from 1 to 40, to indicate the importance of an event in which the fan speed exceeds the threshold. The default is 10.

Data Collection

Collect data for fan 1 speed? Select Yes to collect data about fan speed for reports and graphs. The default is unselected.

Monitor fan 2 speed (BCM 50 only)

Event Notification

Raise event if fan 2 speed exceeds threshold?

Select Yes to raise an event if the speed of fan 2 on a BCM 50 exceeds the threshold that you set. The default is unselected.

Threshold - Maximum fan 2 speed

Specify the highest fan speed that can occur before an event is raised. The default is 10000 RPMs.

Event severity when fan 2 speed exceeds threshold

Set the severity level, from 1 to 40, to indicate the importance of an event in which the fan speed exceeds the threshold. The default is 10.

Data Collection

Collect data for fan 2 speed? Select Yes to collect data about fan speed for reports and graphs. The default is unselected.

Monitor v5 voltage level

Event Notification

Raise event if v5 voltage level exceeds or falls below threshold?

Select Yes to raise an event if the v5 power supply voltage level exceeds or falls below the thresholds that you set. The default is unselected.

Note You cannot enable an upper or lower threshold unless you check this option.

Upper threshold Select Enable to use an upper threshold value. The default is unselected.

Threshold - Maximum v5 voltage level

Specify the highest voltage level that can occur before an event is raised. The default is 5.25 volts.

Event severity when v5 voltage level exceeds threshold

Set the severity level, from 1 to 40, to indicate the importance of an event in which the voltage level exceeds the threshold. The default is 10.

Lower threshold Select Enable to use a lower threshold value. The default is unselected.

Threshold - Minimum v5 voltage level

Specify the lowest voltage level that can occur before an event is raised. The default is 4.75 volts.

Event severity when v5 voltage level falls below threshold

Set the severity level, from 1 to 40, to indicate the importance of an event in which the voltage level falls below the threshold. The default is 10.

Data Collection

Collect data for v5 voltage level?

Select Yes to collect data about voltage level for reports and graphs. The default is unselected.

Description How To Set It

Chapter 3 • NortelBCMx Knowledge Scripts 21

Page 30: NetIQ AppManager Nortel BCMx · Introducing AppManager for Nortel BCMx 1 Features and Benefits ... • Nortel BCM alarms

Monitor v+12 voltage level

Event Notification

Raise event if v+12 voltage level exceeds or falls below threshold?

Select Yes to raise an event if the v+12 power supply voltage level exceeds or falls below the thresholds that you set. The default is unselected.

Note You cannot enable an upper or lower threshold unless you check this option.

Upper threshold Select Enable to use an upper threshold value. The default is unselected.

Threshold - Maximum v+12 voltage level

Specify the highest voltage level that can occur before an event is raised. The default is 12.6 volts.

Event severity when v+12 voltage level exceeds threshold

Set the severity level, from 1 to 40, to indicate the importance of an event in which the voltage level exceeds the threshold. The default is 10.

Lower threshold Select Enable to use a lower threshold value. The default is unselected.

Threshold - Minimum v+12 voltage level

Specify the lowest voltage level that can occur before an event is raised. The default is 11.4 volts.

Event severity when v+12 voltage level falls below threshold

Set the severity level, from 1 to 40, to indicate the importance of an event in which the voltage level falls below the threshold. The default is 10.

Data Collection

Collect data for v+12 voltage level?

Select Yes to collect data about voltage level for reports and graphs. The default is unselected.

Monitor v-12 voltage level (BCM 200/400 only)

Event Notification

Raise event if v-12 voltage level exceeds or falls below threshold?

Select Yes to raise an event if the v-12 power supply voltage level exceeds or falls below the thresholds that you set. The default is unselected.

Note You cannot enable an upper or lower threshold unless you check this option.

Upper threshold Select Enable to use an upper threshold value. The default is unselected.

Threshold - Maximum v-12 voltage level

Specify the highest voltage level that can occur before an event is raised. The default is -12.6 volts.

Event severity when v-12 voltage level exceeds threshold

Set the severity level, from 1 to 40, to indicate the importance of an event in which the voltage level exceeds the threshold. The default is 10.

Lower threshold Select Enable to use a lower threshold value. The default is unselected.

Threshold - Minimum v-12 voltage level

Specify the lowest voltage level that can occur before an event is raised. The default is -11.4 volts.

Event severity when v-12 voltage level falls below threshold

Set the severity level, from 1 to 40, to indicate the importance of an event in which the voltage level falls below the threshold. The default is 10.

Data Collection

Collect data for v-12 voltage level?

Select Yes to collect data about voltage level for reports and graphs. The default is unselected.

Monitor vcc voltage level (BCM 50 only)

Event Notification

Description How To Set It

22 Management Guide

Page 31: NetIQ AppManager Nortel BCMx · Introducing AppManager for Nortel BCMx 1 Features and Benefits ... • Nortel BCM alarms

Raise event if vcc voltage level exceeds or falls below threshold?

Select Yes to raise an event if the vcc power supply voltage level exceeds or falls below the thresholds that you set. The default is unselected.

vcc refers to voltage from a power supply connected to the collector terminal of a bipolar transistor.

Note You cannot enable an upper or lower threshold unless you check this option.

Upper threshold Select Enable to use an upper threshold value. The default is unselected.

Threshold - Maximum vcc voltage level

Specify the highest voltage level that can occur before an event is raised. The default is 3.4 volts.

Event severity when vcc voltage level exceeds threshold

Set the severity level, from 1 to 40, to indicate the importance of an event in which the voltage level exceeds the threshold. The default is 10.

Lower threshold Select Enable to use a lower threshold value. The default is unselected.

Threshold - Minimum vcc voltage level

Specify the lowest voltage level that can occur before an event is raised. The default is 3.2 volts.

Event severity when vcc voltage level falls below threshold

Set the severity level, from 1 to 40, to indicate the importance of an event in which the voltage level falls below the threshold. The default is 10.

Data Collection

Collect data for vcc voltage level?

Select Yes to collect data about voltage level for reports and graphs. The default is unselected.

Monitor vccp voltage level (BCM 50 only)

Event Notification

Raise event if vccp voltage level exceeds or falls below threshold?

Select Yes to raise an event if the vccp power supply voltage level exceeds or falls below the thresholds that you set. The default is unselected.

Note You cannot enable an upper or lower threshold unless you check this option.

Upper threshold Select Enable to use an upper threshold value. The default is unselected.

Threshold - Maximum vccp voltage level

Specify the highest voltage level that can occur before an event is raised. The default is 1.442 volts.

Event severity when vccp voltage level exceeds threshold

Set the severity level, from 1 to 40, to indicate the importance of an event in which the voltage level exceeds the threshold. The default is 10.

Lower threshold Select Enable to use a lower threshold value. The default is unselected.

Threshold - Minimum vccp voltage level

Specify the lowest voltage level that can occur before an event is raised. The default is 1.358 volts.

Event severity when vccp voltage level falls below threshold

Set the severity level, from 1 to 40, to indicate the importance of an event in which the voltage level falls below the threshold. The default is 10.

Data Collection

Collect data for vccp voltage level?

Select Yes to collect data about voltage level for reports and graphs. The default is unselected.

Monitor v3.3 Standby voltage level (BCM 200/400 only)

Event Notification

Raise event if v3.3 Standby voltage level exceeds or falls below threshold?

Select Yes to raise an event if the v3.3 Standby power supply voltage level exceeds or falls below the thresholds that you set. The default is Yes.

Note You cannot enable an upper or lower threshold unless you check this option.

Description How To Set It

Chapter 3 • NortelBCMx Knowledge Scripts 23

Page 32: NetIQ AppManager Nortel BCMx · Introducing AppManager for Nortel BCMx 1 Features and Benefits ... • Nortel BCM alarms

Upper threshold Select Enable to use an upper threshold value. The default is unselected.

Threshold - Maximum v3.3 Standby voltage level

Specify the highest voltage level that can occur before an event is raised. The default is 3.4 volts.

Event severity when v3.3 Standby voltage level exceeds threshold

Set the severity level, from 1 to 40, to indicate the importance of an event in which the voltage level exceeds the threshold. The default is 10.

Lower threshold Select Enable to use a lower threshold value. The default is unselected.

Threshold - Minimum v3.3 Standby voltage level

Specify the lowest voltage level that can occur before an event is raised. The default is 3.2 volts.

Event severity when v3.3 Standby voltage level falls below threshold

Set the severity level, from 1 to 40, to indicate the importance of an event in which the voltage level falls below the threshold. The default is 10.

Data Collection

Collect data for v3.3 Standby voltage level?

Select Yes to collect data about voltage level for reports and graphs. The default is unselected.

Monitor v3.3 One voltage level (BCM 200/400 only)

Event Notification

Raise event if v3.3 One voltage level exceeds or falls below threshold?

Select Yes to raise an event if the v3.3 One power supply voltage level exceeds or falls below the thresholds that you set. The default is Yes.

Note You cannot enable an upper or lower threshold unless you check this option.

Upper threshold Select Enable to use an upper threshold value. The default is Unchecked.

Threshold - Maximum v3.3 One voltage level

Specify the highest voltage level that can occur before an event is raised. The default is 3.4 volts.

Event severity when v3.3 One voltage level exceeds threshold

Set the severity level, from 1 to 40, to indicate the importance of an event in which the voltage level exceeds the threshold. The default is 10.

Lower threshold Select Enable to use a lower threshold value. The default is unselected.

Threshold - Minimum v3.3 One voltage level

Specify the lowest voltage level that can occur before an event is raised. The default is 3.2 volts.

Event severity when v3.3 One voltage level falls below threshold

Set the severity level, from 1 to 40, to indicate the importance of an event in which the voltage level falls below the threshold. The default is 10.

Data Collection

Collect data for v3.3 One voltage level?

Select Yes to collect data about voltage level for reports and graphs. The default is unselected.

Monitor v3.3 Two voltage level (BCM 200/400 only)

Event Notification

Raise event if v3.3 Two voltage level exceeds or falls below threshold?

Select Yes to raise an event if the v3.3 Two power supply voltage level exceeds or falls below the thresholds that you set. The default is Yes.

Note You cannot enable an upper or lower threshold unless you check this option.

Upper threshold Select Enable to use an upper threshold value. The default is Unchecked.

Threshold - Maximum v3.3 Two voltage level

Specify the highest voltage level that can occur before an event is raised. The default is 3.4 volts.

Description How To Set It

24 Management Guide

Page 33: NetIQ AppManager Nortel BCMx · Introducing AppManager for Nortel BCMx 1 Features and Benefits ... • Nortel BCM alarms

Event severity when v3.3 Two voltage level exceeds threshold

Set the severity level, from 1 to 40, to indicate the importance of an event in which the voltage level exceeds the threshold. The default is 10.

Lower threshold Select Enable to use a lower threshold value. The default is Unchecked.

Threshold - Minimum v3.3 Two voltage level

Specify the lowest voltage level that can occur before an event is raised. The default is 3.2 volts.

Event severity when v3.3 Two voltage level falls below threshold

Set the severity level, from 1 to 40, to indicate the importance of an event in which the voltage level falls below the threshold. The default is 10.

Data Collection

Collect data for v3.3 Two voltage level?

Select Yes to collect data about voltage level for reports and graphs. The default is unselected.

Description How To Set It

Chapter 3 • NortelBCMx Knowledge Scripts 25

Page 34: NetIQ AppManager Nortel BCMx · Introducing AppManager for Nortel BCMx 1 Features and Benefits ... • Nortel BCM alarms

HealthCheckUse this Knowledge Script to monitor the operational status of Nortel BCM services. A data point of 100 is recorded if the service is running; a data point of 0 is recorded if the service is not running. Possible non-running states include start pending, stopped, stop pending, continue pending, paused, and pause pending.

This script raises an event when a monitored value exceeds a threshold that you set.

It is important to monitor the up-and-down status of vital Nortel BCM services. If any service consumes excessive CPU resources, other services may be adversely affected. Run this script to notify you when a critical service goes down or when the overall percentage of important services drops below the specified threshold. The BCM Reset utility should restart any down service in a timely manner.

Monitored ServicesThe HealthCheck script monitors the operational status of several BCM services. In addition, the script can be configured to monitor the availability percentage of key services. The following table identifies the services that you can monitor with HealthCheck.

Service Name Description Key?

BackupRestoreProviderAgent CIMOM Provider

BCM_DataInterfacesProviderAgent CIMOM Provider

BCM_DCMProviderAgent CIMOM Provider

BCM_DNSProviderAgent CIMOM Provider

BCM_Doorphone CIMOM Provider

BCM_HostProviderAgent CIMOM Provider

BCM_IPMusicProviderAgent CIMOM Provider

BCM_ISDNProviderAgent CIMOM Provider

BCM_LicenseProviderAgent CIMOM Provider

BCM_LogProviderAgent CIMOM Provider

BCM_MIB2ProviderAgent CIMOM Provider

BCM_ModemDialUpProviderAgent CIMOM Provider

BCM_NetLinkMgrProviderAgent CIMOM Provider

BCM_NetworkInterfacesProviderAgent CIMOM Provider

BCM_PPPoEProviderAgent CIMOM Provider

BCM_PSM_ProviderAgent CIMOM Provider

BCM_RASProviderAgent CIMOM Provider

BCM_RoutingProviderAgent CIMOM Provider

BCM_SecurityProviderAgent CIMOM Provider

BCM_SNMPProviderAgent CIMOM Provider

BCM_SRGProviderAgent CIMOM Provider

BCM_TimeServiceProviderAgent CIMOM Provider

BCM_TimeZoneSettingProviderAgent CIMOM Provider

BCM_WANProviderAgent CIMOM Provider

26 Management Guide

Page 35: NetIQ AppManager Nortel BCMx · Introducing AppManager for Nortel BCMx 1 Features and Benefits ... • Nortel BCM alarms

BCM_WebCacheProviderAgent CIMOM Provider

BcmAmp IP Music

BCMCoreUploadProviderAgent CIMOM Provider

BCMInventoryProviderAgent CIMOM Provider

BCMPerfMonProviderAgent CIMOM Provider

BCMSystemProviderAgent CIMOM Provider

BCMUPSProviderAgent CIMOM Provider

BCMWebProviderAgent CIMOM Provider

btraceserver Plug-in for Authentication and Routing Management for BT

CallPilotProviderAgent CIMOM Provider

CCRSAppServer Call Center Reporting Service Yes

CDRProviderAgent CIMOM Provider

CDRService Call Detail Recording service

cfsserver Component Feature service Yes

core_file_monitor Core File Monitor

coreauthservice CoreTel Authentication Service

CoreTel Main Telephony Process Yes

CoreTelProviderAgent CIMOM Provider

crond CRON Scheduler Daemon

Cte Computer Telephony Engine

ctiserver Computer Telephony Integration Yes

DataDebugToolsProviderAgent CIMOM Provider

dhcpd DHCP Server Daemon Yes

DHCPProviderAgent CIMOM Provider

DiaLogger System Logging Mechanism

DSCProviderAgent CIMOM Provider

EchoServer Echo Server

feps Functional Endpoint Proxy Server Yes

gated Router SNMP Subagent

HGMetricsReporter Hunt Group Metrics

HotDesking used with IP sets

httpd http Daemon

ipppd.ippp0-15 Router/WAN Services Yes

IPSecProviderAgent CIMOM Provider

IpTelProviderAgent CIMOM Provider

IVRProviderAgent CIMOM Provider

LanCteProviderAgent CIMOM Provider

Service Name Description Key?

Chapter 3 • NortelBCMx Knowledge Scripts 27

Page 36: NetIQ AppManager Nortel BCMx · Introducing AppManager for Nortel BCMx 1 Features and Benefits ... • Nortel BCM alarms

Monitoring in SRG ModeThis script supports BCM 50 hardware running Nortel Survivable Remote Gateway (SRG) software, including instances when the SRG shifts to local mode for any reason.

Resource ObjectNortel_BCMx

LANProviderAgent CIMOM Provider

lms Line Monitor Server

LogManagement Log File Management Service

mgs Media Gateway Server Yes

mmdp IVR Service Yes

modemcc Modem Call Control Yes

monit Monitoring Daemon

mps IP Telephony - Media Path Yes

MscService Media Services Card Service Yes

Msm Media Services Manager Yes

MsmProviderAgent CIMOM Provider

NetworkStatisticsProviderAgent CIMOM Provider

NnuScheduler System Scheduler

owcimomd Open WBEM CIMOM Server Daemon Yes

Pdrd Persistence Data Repository service Yes

psm Process Status Monitor service Yes

qmond QoS Monitor

RAIDProviderAgent CIMOM Provider

securityservice Authentication and Authorization

snmpd SNMP Server Daemon

SoftwareUpdateProviderAgent CIMOM Provider

srg Survivable Remote Gateway Service Yes

srp IVR Service Yes

ssba System Set Based Admin service Yes

sshd Secure Shell Daemon

SyslogListener Syslog Receiver

tmwservice Time service

ToneSrvr Tone Server

utps UniSTIM Terminal Proxy Server Yes

voicemail Voice Mail Process Yes

Wan WAN Service Yes

Service Name Description Key?

28 Management Guide

Page 37: NetIQ AppManager Nortel BCMx · Introducing AppManager for Nortel BCMx 1 Features and Benefits ... • Nortel BCM alarms

Default ScheduleThe default interval for this script is 12 minutes.

Setting Parameter ValuesSet the following parameters as needed.

Description How To Set It

General Settings

Job Failure Notification

Event severity when job fails Set the severity level, from 1 to 40, to indicate the importance of an event raised when the HealthCheck job fails. The default is 5.

Raise event if services are not available?

Select Yes to raise an event if any monitored service is not available. The default is Yes.

Event severity when services are not available

Set the severity level, from 1 to 40, to indicate the importance of an event in which a monitored service is not available. The default is 10.

Monitor Key Service Availability

Event Notification

Raise event if key service availability falls below threshold?

Select Yes to raise an event if the percentage of key service availability falls below the threshold that you set. The default is Yes.

Threshold - Minimum key service availability

Specify the lowest percentage of key service availability that can occur before an event is raised. The default is 100%.

Event severity when key service availability falls below threshold

Set the severity level, from 1 to 40, to indicate the importance of an event in which the percentage of key service availability falls below the threshold. The default is 10.

Data Collection

Collect data for key service availability?

Select Yes to collect data about key service availability for reports and graphs. The default is unselected.

Chapter 3 • NortelBCMx Knowledge Scripts 29

Page 38: NetIQ AppManager Nortel BCMx · Introducing AppManager for Nortel BCMx 1 Features and Benefits ... • Nortel BCM alarms

HuntGroupUsageUse this Knowledge Script to monitor call statistics for one or more hunt groups: busy percentage, abandoned percentage, average time in queue, and overflow percentage. This script raises an event if any monitored value exceeds the threshold that you set. In addition, this script generates data streams for percentage of abandoned calls, percentage of busy calls, overflow percentage, average time in queue, total calls, and total answers.

Monitoring in SRG ModeThis script supports BCM 50 hardware running Nortel Survivable Remote Gateway (SRG) software, including instances when the SRG shifts to local mode for any reason.

Resource ObjectNortel_BCMx_HuntGroup

Default ScheduleThe default interval for this script is five minutes.

Setting Parameter ValuesSet the following parameters as needed.

Description How To Set It

General Settings

Job Failure Notification

Event severity when job fails Set the severity level, from 1 to 40, to indicate the importance of an event raised when the HuntGroupUsage job fails. The default is 5.

Monitor Abandoned Percentage

Event Notification

Raise event if abandoned percentage exceeds threshold?

Select Yes to raise an event if the percentage of abandoned calls exceeds the threshold that you set. The default is Yes.

Threshold - Maximum abandoned percentage

Specify the highest percentage of abandoned calls that can occur before an event is raised. The default is 5%.

Event severity when abandoned percentage exceeds threshold

Set the severity level, from 1 to 40, to indicate the importance of an event in which the percentage of abandoned calls exceeds the threshold. The default is 10.

Data Collection

Collect data for abandoned percentage?

Select Yes to collect data about the percentage of abandoned calls for reports and graphs. The default is unselected.

Monitor Busy Percentage

Event Notification

30 Management Guide

Page 39: NetIQ AppManager Nortel BCMx · Introducing AppManager for Nortel BCMx 1 Features and Benefits ... • Nortel BCM alarms

Raise event if busy percentage exceeds threshold?

Select Yes to raise an event if the percentage of busy calls exceeds the threshold that you set. The default is Yes.

Threshold - Maximum busy percentage

Specify the highest percentage of busy calls that can occur before an event is raised. The default is 5%.

Event severity when busy percentage exceeds threshold

Set the severity level, from 1 to 40, to indicate the importance of an event in which the percentage of busy calls exceeds the threshold. The default is 10.

Data Collection

Collect data for busy percentage?

Select Yes to collect data about the percentage of busy calls for reports and graphs. The default is unselected.

Monitor Overflow Percentage

Event Notification

Raise event if overflow percentage exceeds threshold?

Select Yes to raise an event if the percentage of overflow calls exceeds the threshold that you set. The default is Yes.

Threshold - Maximum overflow percentage

Specify the highest percentage of overflow calls that can occur before an event is raised. The default is 25%.

Event severity when overflow percentage exceeds threshold

Set the severity level, from 1 to 40, to indicate the importance of an event in which the percentage of overflow calls exceeds the threshold. The default is 10.

Data Collection

Collect data for overflow percentage?

Select Yes to collect data about the percentage of overflow calls for reports and graphs. The default is unselected.

Monitor Average Time in Queue

Event Notification

Raise event if average time in queue exceeds threshold?

Select Yes to raise an event if the average time calls spend in queue exceeds the threshold that you set. The default is Yes.

Threshold - Maximum average time in queue

Specify the longest average time that calls can spend in queue before an event is raised. The default is 45 seconds.

Event severity when average time in queue exceeds threshold

Set the severity level, from 1 to 40, to indicate the importance of an event in which the average time calls spend in queue exceeds the threshold. The default is 10.

Data Collection

Collect data for average time in queue?

Select Yes to collect data about average queue time for reports and graphs. The default is unselected.

Monitor Total Calls

Data Collection

Collect data for total calls? Select Yes to collect data about the total number of calls for reports and graphs. The default is unselected.

Monitor Total Answers

Data Collection

Collect data for total answers?

Select Yes to collect data about the total number of answered calls for reports and graphs. The default is unselected.

Description How To Set It

Chapter 3 • NortelBCMx Knowledge Scripts 31

Page 40: NetIQ AppManager Nortel BCMx · Introducing AppManager for Nortel BCMx 1 Features and Benefits ... • Nortel BCM alarms

InterfaceHealthUse this Knowledge Script to monitor the operational status of interfaces for a BCM. This script raises an event when interface status changes. In addition, this script generates a data stream for interface availability.

Monitoring in SRG ModeThis script supports BCM 50 hardware running Nortel Survivable Remote Gateway (SRG) software, including instances when the SRG shifts to local mode for any reason.

Resource ObjectNortel_BCMx_LANLink

Default ScheduleThe default interval for this script is five minutes.

Setting Parameter ValuesSet the following parameters as needed.

Description How To Set It

General Settings

Job Failure Notification

Event severity when job fails Set the severity level, from 1 to 40, to indicate the importance of an event raised when the InterfaceHealth job fails. The default is 5.

Raise event if interface goes down?

Select Yes to raise an event if interface status changes to “down.” The default is Yes.

Event severity when interface is down

Set the severity level, from 1 to 40, to indicate the importance of an event in which interface status changes to “down.” The default is 5.

Raise event if interface comes up?

Select Yes to raise an event if an interface’s status changes to “up.” The default is Yes.

Event severity when interface is up

Set the severity level, from 1 to 40, to indicate the importance of an event in which interface status changes to “up.” The default is 30.

Monitor Interface Availability

Data Collection

Collect data for interface availability?

Select Yes to collect data about interface availability for reports and graphs. If enabled, data collection returns a value of 100 if the interface is available or a value of 0 if the interface is not available. The default is unselected.

32 Management Guide

Page 41: NetIQ AppManager Nortel BCMx · Introducing AppManager for Nortel BCMx 1 Features and Benefits ... • Nortel BCM alarms

LinkUtilizationUse this Knowledge Script to monitor LAN links on a BCM. This script monitors bandwidth utilization (including inbound and outbound utilization), bytes sent and received (bytes per second since the last polling period), and percentage of packet errors.

This script raises an event when a monitored value exceeds the threshold that you set. In addition, this script generates data streams for bandwidth utilization, packet errors, outbound bandwidth utilization, inbound bandwidth utilization, sent bytes, and received bytes.

Monitoring in SRG ModeThis script supports BCM 50 hardware running Nortel Survivable Remote Gateway (SRG) software, including instances when the SRG shifts to local mode for any reason.

For both modes, this script can monitor packet errors, sent bytes, and received bytes. It cannot monitor bandwidth utilization for either mode.

Resource ObjectNortel_BCMx_LANLink

Default ScheduleThe default interval for this script is five minutes.

Setting Parameter ValuesSet the following parameters as needed.

Description How To Set It

General Settings

Job Failure Notification

Event severity when job fails Set the severity level, from 1 to 40, to indicate the importance of an event raised when the LinkUtilization job fails. The default is 5.

Monitor Bandwidth Utilization

Event Notification

Raise event if bandwidth utilization exceeds threshold?

Select Yes to raise an event if bandwidth (inbound and outbound) utilization exceeds the threshold that you set. The default is Yes.

Threshold - Maximum bandwidth utilization

Specify the highest percentage of bandwidth utilization that can occur before an event is raised. The default is 50%.

Event severity when bandwidth utilization exceeds threshold

Set the severity level, from 1 to 40, to indicate the importance of an event in which bandwidth utilization exceeds the threshold. The default is 10.

Data Collection

Collect data for bandwidth utilization?

Select Yes to collect data about inbound and outbound bandwidth utilization for reports and graphs. The default is unselected.

Monitor Packet Errors

Chapter 3 • NortelBCMx Knowledge Scripts 33

Page 42: NetIQ AppManager Nortel BCMx · Introducing AppManager for Nortel BCMx 1 Features and Benefits ... • Nortel BCM alarms

Event Notification

Raise event if packet errors exceed threshold?

Select Yes to raise an event if the percentage of packet errors exceeds the threshold that you set. The default is Yes.

Hint When a packet is dropped during a VoIP transmission, a conversation can lose an entire syllable or word. Obviously, data loss can severely impair call quality. Set this parameter to Yes to receive immediate notification of packet loss that exceeds the threshold that you set.

Threshold - Maximum packet errors

Specify the highest percentage of packet errors that can occur before an event is raised. The default is 8%.

Event severity when packet errors exceed threshold

Set the severity level, from 1 to 40, to indicate the importance of an event in which the percentage of packet errors exceeds the threshold. The default is 10.

Data Collection

Collect data for packet errors?

Select Yes to collect data about the percentage of packet errors for reports and graphs. The default is unselected.

Monitor Outbound Bandwidth Utilization

Event Notification

Raise event if outbound bandwidth utilization exceeds threshold?

Select Yes to raise an event if outbound bandwidth utilization exceeds the threshold that you set. The default is Yes.

Threshold - Maximum outbound bandwidth utilization

Specify the highest percentage of outbound bandwidth utilization that can occur before an event is raised. The default is 50%.

Event severity when outbound bandwidth utilization exceeds threshold

Set the severity level, from 1 to 40, to indicate the importance of an event in which outbound bandwidth utilization exceeds the threshold. The default is 10.

Data Collection

Collect data for outbound bandwidth utilization?

Select Yes to collect data about the percentage of outbound bandwidth utilization for reports and graphs. The default is unselected.

Monitor Inbound Bandwidth Utilization

Event Notification

Raise event if inbound bandwidth utilization exceeds threshold?

Select Yes to raise an event if inbound bandwidth utilization exceeds the threshold that you set. The default is Yes.

Threshold - Maximum inbound bandwidth utilization

Specify the highest percentage of inbound bandwidth utilization that can occur before an event is raised. The default is 50%.

Event severity when inbound bandwidth utilization exceeds threshold

Set the severity level, from 1 to 40, to indicate the importance of an event in which inbound bandwidth utilization exceeds the threshold. The default is 10.

Data Collection

Collect data for inbound bandwidth utilization?

Select Yes to collect data about the percentage of inbound bandwidth utilization for reports and graphs. The default is unselected.

Monitor Bytes Sent

Data Collection

Collect data for bytes sent? Select Yes to collect data about the number of bytes sent per second for reports and graphs. The default is unselected.

Description How To Set It

34 Management Guide

Page 43: NetIQ AppManager Nortel BCMx · Introducing AppManager for Nortel BCMx 1 Features and Benefits ... • Nortel BCM alarms

Monitor Bytes Received

Data Collection

Collect data for bytes received?

Select Yes to collect data about the number of bytes received per second for reports and graphs. The default is unselected.

Description How To Set It

Chapter 3 • NortelBCMx Knowledge Scripts 35

Page 44: NetIQ AppManager Nortel BCMx · Introducing AppManager for Nortel BCMx 1 Features and Benefits ... • Nortel BCM alarms

LogicalDiskSpaceUse this Knowledge Script to monitor logical disk space usage and availability. This script raises an event when any monitored value exceeds a threshold that you set. In addition, this script generates data streams for used disk space and available disk space.

Resource ObjectNortel_BCMx_LogicalDisk

The LogicalDiskSpace Knowledge Script is a member of the NortelBCMx Recommended Knowledge Script Group (KSG), which allows you to run all recommended scripts at one time. However, there are limits on the number of Logical Disk objects on which the LogicalDiskSpace script can run. If you run the KSG on more objects than the LogicalDiskSpace script allows, you will receive an error message indicating that the number of target objects has exceeded its limit. If you receive this error message, remove the LogicalDiskSpace script from the KSG and run LogicalDiskSpace alone on fewer Logical Disk resources.

Default ScheduleThe default interval for this script is five minutes.

Setting Parameter ValuesSet the following parameters as needed.

Description How To Set It

General Settings

Job Failure Notification

Event severity when job fails Set the severity level, from 1 to 40, to indicate the importance of an event raised when the LogicalDiskSpace job fails. The default is 5.

Monitor Used Disk Space

Event Notification

Raise event if used disk space exceeds threshold?

Select Yes to raise an event if the amount of used disk space exceeds the threshold that you set. The default is Yes.

Threshold - Maximum used disk space

Specify the highest percentage of disk space that can be used before an event is raised. The default is 80%.

Event severity when used disk space exceeds threshold

Set the severity level, from 1 to 40, to indicate the importance of an event in which used disk space exceeds the threshold. The default is 10.

Data Collection

Collect data for used disk space?

Select Yes to collect data about used disk space for reports and graphs. The default is unselected.

Monitor Available Disk Space

Event Notification

Raise event if available disk space falls below threshold?

Select Yes to raise an event if available disk space falls below the threshold that you set. The default is Yes.

36 Management Guide

Page 45: NetIQ AppManager Nortel BCMx · Introducing AppManager for Nortel BCMx 1 Features and Benefits ... • Nortel BCM alarms

Threshold - Minimum available disk space

Specify the lowest amount of disk space that can be available before an event is raised. The default is 10 MB.

Event severity when available disk space falls below threshold

Set the severity level, from 1 to 40, to indicate the importance of an event in which available disk space falls below the threshold. The default is 10.

Data Collection

Collect data for available disk space

Select Yes to collect data about available disk space for reports and graphs. The default is unselected.

Description How To Set It

Chapter 3 • NortelBCMx Knowledge Scripts 37

Page 46: NetIQ AppManager Nortel BCMx · Introducing AppManager for Nortel BCMx 1 Features and Benefits ... • Nortel BCM alarms

PSTNFallbackUse this Knowledge Script to monitor the number of PSTN (Public Switched Telephone Network) fallback attempts and failures that have occurred since the last polling period. Attempts are calls that were not able to route through the preferred trunk. Failures are calls that were not able to route through the fallback trunk.

This script raises an event when any monitored value exceeds a threshold that you set. In addition, this script generates data streams for PSTN fallback attempts and failures.

Monitoring in SRG ModeThis script supports BCM 50 hardware running Nortel Survivable Remote Gateway (SRG) software, including instances when the SRG shifts to local mode for any reason.

Resource ObjectNortel_BCMx_TelephonyFolder

Default ScheduleThe default interval for this script is five minutes.

Setting Parameter ValuesSet the following parameters as needed.

Description How To Set It

General Settings

Job Failure Notification

Event severity when job fails Set the severity level, from 1 to 40, to indicate the importance of an event raised when the PSTNFallback job fails. The default is 5.

Monitor PSTN Fallback Attempts

Event Notification

Raise event if PSTN fallback attempts exceed threshold?

Select Yes to raise an event if the number of fallback attempts exceeds the threshold that you set. The default is Yes.

Threshold - Maximum PSTN fallback attempts

Specify the highest number of fallback attempts that can occur before an event is raised. The default is 0 attempts.

Event severity when PSTN fallback attempts exceed threshold

Set the severity level, from 1 to 40, to indicate the importance of an event in which the number of fallback attempts exceeds the threshold. The default is 20.

Data Collection

Collect data for PSTN fallback attempts

Select Yes to collect data about the number of fallback attempts for reports and graphs. The default is unselected.

Monitor PSTN Fallback Failures

Event Notification

38 Management Guide

Page 47: NetIQ AppManager Nortel BCMx · Introducing AppManager for Nortel BCMx 1 Features and Benefits ... • Nortel BCM alarms

Raise event if PSTN fallback failures exceed threshold?

Select Yes to raise an event if the number of fallback failures exceeds the threshold that you set. The default is Yes.

Threshold - Maximum PSTN fallback failures

Specify the highest number of fallback failures that can occur before an event is raised. The default is 0 failures.

Event severity when PSTN fallback failures exceed threshold

Set the severity level, from 1 to 40, to indicate the importance of an event in which the number of fallback failures exceeds the threshold. The default is 10.

Data Collection

Collect data for available PSTN fallback failures

Select Yes to collect data about the number of fallback failures for reports and graphs. The default is unselected.

Description How To Set It

Chapter 3 • NortelBCMx Knowledge Scripts 39

Page 48: NetIQ AppManager Nortel BCMx · Introducing AppManager for Nortel BCMx 1 Features and Benefits ... • Nortel BCM alarms

QoSLogUse this Knowledge Script to monitor the MOS estimates for several codecs: G.711a, G.711u, G.723 5.3 kbps, G.723 6.3 kbps, and G.729 and G.729A (in the outgoing call direction only). This script raises an event if any MOS estimate falls below the threshold you set. In addition, this script generates data streams for MOS estimates for each monitored codec.

If you use VoIP trunks, run this script to gather information from the BCM QoS Monitor log in order to verify that QoS between target BCMs is maintaining acceptable MOS. For more information, see “Understanding the Mean Opinion Score” on page 43.

PrerequisiteEnable the QoS Monitor to log MOS scores. For more information, see “Enabling QoS Monitor” on page 42.

Resource ObjectNortel_BCMx_TelephonyFolder

Default ScheduleThe default interval for this script is five minutes.

Setting Parameter ValuesSet the following parameters as needed.

Description How To Set It

General Settings

Job Failure Notification

Event severity when job fails Set the severity level, from 1 to 40, to indicate the importance of an event in which the QOSLog job fails. The default is 5.

Raise event if QoS monitor is not running from device?

Select Yes to raise an event if QoS Monitor is not running. The default is Yes.

The QoS Monitor must be running in order to log the MOS scores this script monitors.

Event severity when QoS monitor is not running from device

Set the severity level, from 1 to 40, to indicate the importance of an event in which QoS Monitor is not running. The default is 5.

Monitor G.711a MOS

Event Notification

Raise event if G.711a MOS falls below threshold?

Select Yes to raise an event if the MOS for the G.711a codec falls below the threshold that you set. The default is Yes.

Threshold - Minimum G.711a MOS

Specify the lowest MOS that can occur before an event is raised. The default is 3.60.

Event severity when G.711a MOS falls below threshold

Set the severity level, from 1 to 40, to indicate the importance of an event in which the MOS falls below the threshold. The default is 5.

Data Collection

40 Management Guide

Page 49: NetIQ AppManager Nortel BCMx · Introducing AppManager for Nortel BCMx 1 Features and Benefits ... • Nortel BCM alarms

Collect data for G.711a MOS?

Select Yes to collect data about G.711a MOS for reports and graphs. The default is unselected.

Monitor G.711u MOS

Event Notification

Raise event if G.711u MOS falls below threshold?

Select Yes to raise an event if the MOS for the G.711u codec falls below the threshold that you set. The default is Yes.

Threshold - Minimum G.711u MOS

Specify the lowest MOS that can occur before an event is raised. The default is 3.60.

Event severity when G.711u MOS falls below threshold

Set the severity level, from 1 to 40, to indicate the importance of an event in which the MOS falls below the threshold. The default is 5.

Data Collection

Collect data for G.711u MOS?

Select Yes to collect data about G.711u MOS for reports and graphs. The default is unselected.

Monitor G.723 5.3 kbps MOS

Event Notification

Raise event if G.723 5.3 kbps MOS falls below threshold?

Select Yes to raise an event if the MOS for the G.723 5.3 kbps codec falls below the threshold that you set. The default is Yes.

Threshold - Minimum G.723 5.3 kbps MOS

Specify the lowest MOS that can occur before an event is raised. The default is 3.60.

Event severity when G.723 5.3 kbps MOS falls below threshold

Set the severity level, from 1 to 40, to indicate the importance of an event in which the MOS falls below the threshold. The default is 5.

Data Collection

Collect data for G.723 5.3 kbps MOS?

Select Yes to collect data about G.723 5.3 kbps MOS for reports and graphs. The default is unselected.

Monitor G.723 6.3 kbps MOS

Event Notification

Raise event if G.723 6.3 kbps MOS falls below threshold?

Select Yes to raise an event if the MOS for the G.723 6.3 kbps codec falls below the threshold that you set. The default is Yes.

Threshold - Minimum G.723 6.3 kbps MOS

Specify the lowest MOS that can occur before an event is raised. The default is 3.60.

Event severity when G.723 6.3 kbps MOS falls below threshold

Set the severity level, from 1 to 40, to indicate the importance of an event in which the MOS falls below the threshold. The default is 5.

Data Collection

Collect data for G.723 6.3 kbps MOS?

Select Yes to collect data about G.723 6.3 kbps MOS for reports and graphs. The default is unselected.

Monitor G.729 MOS

Event Notification

Raise event if G.729 MOS falls below threshold?

Select Yes to raise an event if the MOS for the G.729 codec falls below the threshold that you set. The default is Yes.

Threshold - Minimum G.729 MOS

Specify the lowest MOS that can occur before an event is raised. The default is 3.60.

Description How To Set It

Chapter 3 • NortelBCMx Knowledge Scripts 41

Page 50: NetIQ AppManager Nortel BCMx · Introducing AppManager for Nortel BCMx 1 Features and Benefits ... • Nortel BCM alarms

Enabling QoS MonitorIf you use VoIP trunks, enable QoS Monitor in BCM before running the QoSLog Knowledge Script.

To enable QoS Monitor:

1. Log in to Element Manager.

2. On the Administration tab, expand System Metrics (for BCM 50 devices) or System Status (for BCM 4.0 devices), and then select QoS Monitor.

3. From the Monitoring mode list, select Enabled in QoS-Monitor mode.

For more information about VoIP trunks, see the “VoIP trunk gateways” chapter of the Networking Configuration Guide for your BCM device. For information about enabling the QoS Monitor, see the Administration Guide for your BCM device.

Understanding CodecsIn a VoIP transmission, the codec samples the sound and determines the data rate. A codec converts analog signals to digital (outbound) and digital signals to analog (inbound) for voice transmissions, and compresses (outbound) and decompresses (inbound) the digital information.

If you use VoIP trunks, use the QoSLog Knowledge Script to monitor the Mean Opinion Score (MOS) for six codec types. For more information, see “Understanding the Mean Opinion Score” on page 43.

Event severity when G.729 MOS falls below threshold

Set the severity level, from 1 to 40, to indicate the importance of an event in which the MOS falls below the threshold. The default is 5.

Data Collection

Collect data for G.729 MOS? Select Yes to collect data about G.729 MOS for reports and graphs. The default is unselected.

Monitor G.729A MOS

Event Notification

Raise event if G.729A MOS falls below threshold?

Select Yes to raise an event if the MOS for the G.729A codec falls below the threshold that you set. The default is Yes.

Threshold - Minimum G.729A MOS

Specify the lowest MOS that can occur before an event is raised. The default is 3.60.

Event severity when G.729A MOS falls below threshold

Set the severity level, from 1 to 40, to indicate the importance of an event in which the MOS falls below the threshold. The default is 5.

Data Collection

Collect data for G.729A MOS?

Select Yes to collect data about G.729A MOS for reports and graphs. The default is unselected.

Codec Description

G.711a ITU standard for H.323-compliant codecs. Uses the A-law for companding, a popular standard in Europe.

G.711u ITU standard for H.323-compliant codecs. Uses the U-law for companding, the most frequently used method in North America.

Description How To Set It

42 Management Guide

Page 51: NetIQ AppManager Nortel BCMx · Introducing AppManager for Nortel BCMx 1 Features and Benefits ... • Nortel BCM alarms

Understanding the Mean Opinion ScoreThe Mean Opinion Score (MOS) is an overall score representing the quality of a call. The MOS is a number between 1 and 5. A MOS of 5 is excellent; a MOS of 1 is unacceptably bad. A modified version of the ITU (International Telecommunications Union) G.107 standard E-model equation is used to calculate the MOS. This algorithm is used to evaluate the quality of a transmission by factoring in the “mouth to ear” characteristics of a speech path.

The E-model is a complex calculation, the output of which is a single score called an R-value that is derived from delays and equipment impairment factors. An R-value can be mapped to an estimated MOS. R-values range from 100 (excellent) to 0 (poor). As shown below, an estimated MOS can be calculated directly from an R-value:

G.723-5.3 kbps Dual-rate speech codec for multimedia communications transmitting at 5.3 kbps. Uses the conjugate structure algebraic code excited linear predictive compression (ACELP) algorithm.

G.723-6.3 kbps Dual-rate speech codec for multimedia communications transmitting at 6.3 kbps. Uses the multipulse maximum likelihood quantization (MPMLQ) compression algorithm.

G.729 High-performing codec that offers compression with high quality.

G.729A Less-complex version of the G.729 codec. Developed for simultaneous voice and data applications for which the G.729 codec was too complex. Speech quality is virtually indistinguishable between G.729 and G.729A.

Codec Description

Chapter 3 • NortelBCMx Knowledge Scripts 43

Page 52: NetIQ AppManager Nortel BCMx · Introducing AppManager for Nortel BCMx 1 Features and Benefits ... • Nortel BCM alarms

SystemUpTimeUse this Knowledge Script to monitor the number of seconds that the BCM has been operational since its last reboot. This script raises an event if the system has rebooted. In addition, this script generates a data stream for system availability.

You want to be informed when your BCM has been rebooted. While a BCM is rebooting, calls are not going through. Knowing that the BCM has been rebooted can help prepare you for calls from disgruntled users whose calls were incomplete.

Monitoring in SRG ModeThis script supports BCM 50 hardware running Nortel Survivable Remote Gateway (SRG) software, including instances when the SRG shifts to local mode for any reason.

Resource ObjectNortel_BCMx

Default ScheduleThe default interval for this script is five minutes.

Setting Parameter ValuesSet the following parameters as needed.

Description How To Set It

General Settings

Job Failure Notification

Event severity when job fails Set the severity level, from 1 to 40, to indicate the importance of an event raised when the SystemUpTime job fails. The default is 5.

Raise event if system has rebooted?

Select Yes to raise an event if the BCM has been rebooted. The default is Yes.

Event severity when system has rebooted

Set the severity level, from 1 to 40, to indicate the importance of an event in which the BCM has been rebooted. The default is 10.

Monitor System Up Time

Data Collection

Collect data for system up time?

Select Yes to collect data about system up time (number of seconds that the BCM has been powered on or since its last reboot) for reports and graphs. The default is unselected.

44 Management Guide

Page 53: NetIQ AppManager Nortel BCMx · Introducing AppManager for Nortel BCMx 1 Features and Benefits ... • Nortel BCM alarms

SystemUsageUse this Knowledge Script to monitor the total CPU usage and memory usage for the BCM. This script raises an event when any monitored value exceeds a threshold that you set. In addition, this script generates data streams for CPU usage and memory usage.

Monitoring in SRG ModeThis script supports BCM 50 hardware running Nortel Survivable Remote Gateway (SRG) software, including instances when the SRG shifts to local mode for any reason.

Resource ObjectNortel_BCMx

Default ScheduleThe default interval for this script is five minutes.

Setting Parameter ValuesSet the following parameters as needed.

Description How To Set It

General Settings

Job Failure Notification

Event severity when job fails Set the severity level, from 1 to 40, to indicate the importance of an event raised when the SystemUsage job fails. The default is 5.

Monitor CPU Usage

Event Notification

Raise event if CPU usage exceeds threshold?

Select Yes to raise an event if CPU usage exceeds the threshold that you set. The default is Yes.

Threshold - Maximum CPU usage

Specify the highest CPU usage that can occur before an event is raised. The default is 80%.

Event severity when CPU usage exceeds threshold

Set the severity level, from 1 to 40, to indicate the importance of an event in which CPU usage exceeds the threshold. The default is 10.

Data Collection

Collect data for CPU usage? Select Yes to collect data about CPU usage for reports and graphs. The default is unselected.

Monitor Memory Usage

Event Notification

Raise event if memory usage exceeds threshold?

Select Yes to raise an event if memory usage exceeds the threshold that you set. The default is Yes.

Threshold - Maximum memory usage

Specify the highest memory usage that can occur before an event is raised. The default is 80%.

Event severity when memory usage exceeds threshold

Set the severity level, from 1 to 40, to indicate the importance of an event in which memory usage exceeds the threshold. The default is 10.

Chapter 3 • NortelBCMx Knowledge Scripts 45

Page 54: NetIQ AppManager Nortel BCMx · Introducing AppManager for Nortel BCMx 1 Features and Benefits ... • Nortel BCM alarms

Data Collection

Collect data for memory usage?

Select Yes to collect data about memory usage for reports and graphs. The default is unselected.

Description How To Set It

46 Management Guide

Page 55: NetIQ AppManager Nortel BCMx · Introducing AppManager for Nortel BCMx 1 Features and Benefits ... • Nortel BCM alarms

UPSHealthUse this Knowledge Script to monitor an attached uninterruptible power supply (UPS) for changes in operational status, load status, temperature status, and output and input voltage statuses, as well as temperature, load, and output and input voltage.

By warning you of changes to UPS status, this script can help you prevent outages that affect your users.

This script raises an event if a monitored status changes or if a monitored value exceeds a threshold that you set. In addition, this script generates data streams for UPS temperature, UPS load, UPS output voltage, and UPS input voltage.

Resource ObjectNortel_BCMx_UPS

Default ScheduleThe default interval for this script is five minutes.

Setting Parameter ValuesSet the following parameters as needed.

Description How To Set It

General Settings

Job Failure Notification

Event severity when job fails Set the severity level, from 1 to 40, to indicate the importance of an event raised when the UPSHealth job fails. The default is 5.

Raise event if UPS operational status changes?

Select Yes to raise an event if the UPS operational status changes. The default is unselected.

Event severity when UPS operational status changes

Set the severity level, from 1 to 40, to indicate the importance of an event in which the UPS operational status changes. The default is 30.

Raise event if UPS temperature status changes?

Select Yes to raise an event if the UPS temperature status changes. The default is unselected.

Event severity when UPS temperature status changes

Set the severity level, from 1 to 40, to indicate the importance of an event in which the UPS temperature status changes. The default is 30.

Raise event if UPS load status changes?

Select Yes to raise an event if the UPS load status changes. The default is unselected.

Event severity when UPS load status changes

Set the severity level, from 1 to 40, to indicate the importance of an event in which the UPS load status changes. The default is 30.

Raise event if UPS output voltage status changes?

Select Yes to raise an event if the UPS output voltage status changes. The default is unselected.

Event severity when UPS output voltage status changes

Set the severity level, from 1 to 40, to indicate the importance of an event in which the UPS output voltage status changes. The default is 30.

Chapter 3 • NortelBCMx Knowledge Scripts 47

Page 56: NetIQ AppManager Nortel BCMx · Introducing AppManager for Nortel BCMx 1 Features and Benefits ... • Nortel BCM alarms

Raise event if UPS input voltage status changes?

Select Yes to raise an event if the UPS input voltage status changes. The default is unselected.

Event severity when UPS input voltage status changes

Set the severity level, from 1 to 40, to indicate the importance of an event in which the UPS input voltage status changes. The default is 30.

Monitor Temperature

Event Notification

Raise event if temperature exceeds threshold?

Select Yes to raise an event if the UPS temperature exceeds the threshold that you set. The default is Yes.

Threshold - Maximum temperature

Specify the temperature that can occur before an event is raised. The default is 55º Celsius.

Event severity when temperature exceeds threshold

Set the severity level, from 1 to 40, to indicate the importance of an event in which the temperature exceeds the threshold. The default is 10.

Data Collection

Collect data for temperature?

Select Yes to collect data about temperature for reports and graphs. The default is unselected.

Monitor Load

Event Notification

Raise event if load exceeds threshold?

Select Yes to raise an event if the UPS load exceeds the threshold that you set. The default is unselected.

Threshold - Maximum load Specify the highest percentage of load that can occur before an event is raised. The default is 80%.

Event severity when load exceeds threshold

Set the severity level, from 1 to 40, to indicate the importance of an event in which load exceeds the threshold. The default is 10.

Data Collection

Collect data for load? Select Yes to collect data about load for reports and graphs. The default is unselected.

Monitor Output Voltage

Event Notification

Raise event if output voltage exceeds or falls below threshold?

Select Yes to raise an event if the output voltage level exceeds or falls below the thresholds that you set. The default is unselected.

Upper threshold Select Enable to use an upper threshold value. The default is Enable.

Threshold - Maximum output voltage

Specify the highest output voltage that can occur before an event is raised. The default is 130 volts.

Event severity when output voltage exceeds threshold

Set the severity level, from 1 to 40, to indicate the importance of an event in which output voltage exceeds the threshold. The default is 10.

Lower threshold Select Enable to use a lower threshold value. The default is Enable.

Threshold - Minimum output voltage

Specify the lowest output voltage that can occur before an event is raised. The default is 100 volts.

Event severity when output voltage falls below threshold

Set the severity level, from 1 to 40, to indicate the importance of an event in which output voltage falls below the threshold. The default is 10.

Data Collection

Description How To Set It

48 Management Guide

Page 57: NetIQ AppManager Nortel BCMx · Introducing AppManager for Nortel BCMx 1 Features and Benefits ... • Nortel BCM alarms

Collect data for output voltage?

Select Yes to collect data about output voltage for reports and graphs. The default is unselected.

Monitor Input Voltage

Event Notification

Raise event if input voltage exceeds or falls below threshold?

Select Yes to raise an event if the input voltage level exceeds or falls below the thresholds that you set. The default is unselected.

Upper threshold Select Enable to use an upper threshold value. The default is Enable.

Threshold - Maximum input voltage

Specify the highest input voltage that can occur before an event is raised. The default is 130 volts.

Event severity when input voltage exceeds threshold

Set the severity level, from 1 to 40, to indicate the importance of an event in which input voltage exceeds the threshold. The default is 10.

Lower threshold Select Enable to use a lower threshold value. The default is Enable.

Threshold - Minimum input voltage

Specify the lowest input voltage that can occur before an event is raised. The default is 100 volts.

Event severity when input voltage falls below threshold

Set the severity level, from 1 to 40, to indicate the importance of an event in which input voltage falls below the threshold. The default is 10.

Data Collection

Collect data for input voltage?

Select Yes to collect data about input voltage for reports and graphs. The default is unselected.

Description How To Set It

Chapter 3 • NortelBCMx Knowledge Scripts 49

Page 58: NetIQ AppManager Nortel BCMx · Introducing AppManager for Nortel BCMx 1 Features and Benefits ... • Nortel BCM alarms

Recommended Knowledge Script GroupThe following Knowledge Scripts in the AppManager for Nortel BCMx module are members of the NortelBCMx recommended Knowledge Script Group (KSG).

• Alarms (Configure your Nortel BCM to send SNMP traps to AppManager before using this script. For more information, see “Identifying the SNMP Trap Receiver” on page 14).

• ChassisUsage

• HealthCheck

• InterfaceHealth

• LogicalDiskSpace

• SystemUpTime

• SystemUsage

You can find the NortelBCMx KSG on the RECOMMENDED tab of the Knowledge Script pane of the Operator Console.

All the scripts in the KSG have their parameters set to recommended values. To run all of the recommended scripts at one time, click the RECOMMENDED tab, and then run the NortelBCMx group on a Nortel BCMx resource.

Run the KSG from the Master view, not the NortelBCMx view. In order to use the Discovery_NortelBCMx Knowledge Script in a monitoring policy, the view must include root objects, which are not visible in the NortelBCMx view.

The NortelBCMx KSG enables a “best practices” usage of AppManager for monitoring your Nortel BCM environment. You can use this KSG with AppManager monitoring policies. A monitoring policy, which enables you to efficiently and consistently monitor all the resources in your environment, uses a set of pre-configured Knowledge Scripts to automatically monitor resources as they appear in the TreeView. For more information, see “About Policy-Based Monitoring” in the AppManager Help.

A KSG is composed of a subset of a module’s Knowledge Scripts. The script that belongs to a KSG is a different copy of the original script you access from the NortelBCMx tab. If you modify a script that belongs to a KSG, the parameter settings of the original script in the NortelBCMx tab are not affected.

In some cases, default script parameter settings are different when the script is deployed as part of a KSG, as opposed to when it is deployed alone. The default settings of a script within a group depend on its monitoring purpose within the larger group, and on the intended monitoring scope of that group.

If you modify or remove a script associated with the NortelBCMx KSG and want to restore it to its original form, you can reinstall AppManager for Nortel BCMX on the repository computer or check in the appropriate script from the AppManager\qdb\kp\NortelBCMx directory.

50 Management Guide

Page 59: NetIQ AppManager Nortel BCMx · Introducing AppManager for Nortel BCMx 1 Features and Benefits ... • Nortel BCM alarms

Discovery_NortelBCMxUse this Knowledge Script to discover resource and configuration information for Nortel BCM software version 4.0 and hardware models 50, 50a, 50e, 200, 400, and 1000.

AppManager for Nortel BCMx provides limited support for Survivable Remote Gateway (SRG) mode and local mode with the Alarms, CallByCallLimits, ChassisUsage, HealthCheck, HuntGroupUsage, InterfaceHealth, LinkUtilization, PSTNFallback, SystemUpTime, and SystemUsage Knowledge Scripts. For more information, see the Help for those scripts.

PrerequisiteConfigure your BCM user name and password into AppManager Security Manager. The discovery process will fail if it cannot access this vital information. For more information, see “Configuring the BCM User Name and Password” on page 8.

Resource ObjectNT_MachineFolder

Default ScheduleBy default, this script runs once a week on Sunday at 3 A.M.

Setting Parameter ValuesSet the following parameters as needed.

Parameter How To Set It

General Settings

Job Failure Notification

Event severity when job fails Set the event severity level, from 1 to 40, to reflect the importance of an event in which the Discovery_NortelBCMx job fails. The default is 5.

Raise event if discovery succeeds?

This Knowledge Script always raises an event when the job fails for any reason. In addition, you can set this parameter to Yes to raise an event when the job succeeds. The default is unselected.

Event severity when discovery succeeds

Set the event severity level, from 1 to 40, to reflect the importance of an event in which discovery succeeds. The default is 25.

Raise event if discovery fails? Select Yes to raise an event if discovery fails to find Nortel BCMx resources. The default is Yes.

Event severity when discovery fails Set the event severity level, from 1 to 40, to reflect the importance of an event in which discovery fails to find Nortel BCMx resources. The default is 5.

Raise event if Nortel BCMx agent not installed?

Select Yes to raise an event if the Nortel BCMx managed object is not installed. The default is Yes.

Event severity when Nortel BCMx agent not installed

Set the event severity level, from 1 to 40, to reflect the importance of an event in which the Nortel BCMx managed object is not installed. The default is 15.

Discover Nortel BCMx Devices

Chapter 3 • NortelBCMx Knowledge Scripts 51

Page 60: NetIQ AppManager Nortel BCMx · Introducing AppManager for Nortel BCMx 1 Features and Benefits ... • Nortel BCM alarms

List of Nortel BCMx devices Use this parameter if you have only a few Nortel BCM devices to discover.

Type a list of the devices for which you want to discover resources. Use a comma to separate the names or IP addresses in the list.

For example: 10.0.1.1,10.0.4.1

List of Nortel BCMx device ranges Use this parameter if you have only a few ranges of Nortel BCM devices to discover.

Type a list of IP address ranges (up to 256 addresses) of the devices for which you want to discover resources. Only numbers, dashes, periods, and commas are allowed in the list. Use dashes to define a range.

For example: 10.0.1.1-10.0.1.50,10.0.4.51-10.0.4.100

Full path to file with list of Nortel BCMx devices

Instead of typing each Nortel BCM device separately, you can use this parameter to specify the full path to a file on the agent computer that contains a device name on each line of the file.

Parameter How To Set It