NEMESIS · can be seamlessly integrated with multiple antenna platforms and frequncy band variants...

2
KNOW 2 SOLUTIONS KNOW 2 SOLUTIONS | 3956 MERLIN DRIVE, KISSIMMEE, FLORIDA 34741 | 407.750.9749 CAGE CODE 6QEK4 | DUNS 078405039 | [email protected] | WWW.KNOW2SOLUTIONS.COM NEMESIS NETWORKED ETHERNET MODULATED ENCRYPTION SECURE INFORMATION SYSTEM Key Features » Certified to MIL-STD Environmental, and EMI for air, land and sea » 4CPM/MF-TDMA, HRC/Mx- DMA, and HRC/S2 SCPC return topologies supported » 5, 10, 15, 20, 25 and 35% Roll-Offs supported » High performance concurrent unicast service rates up to 100/25 Mbps » Transmit multicast up to 85 Mbps » Receive multicast support (IGMPv2 / static configuration) up to 200Mbps » VL-SNR support for extended availability and PSD restricted applications » DNS Cache/Relay, TCP Acceleration and Compression, and HTTP pre-fetching » Multi-level Quality of Service with seven Quality of Service Classes » Automatic Uplink Power Control and ACM » Protocol-independent Layer 2 Tunneling » TRANSEC security and Hardware Accelerated AES 256-bit encryption » Pre-placed Public Key (PPPK) Two-Factor Authentication » Dynamic Updates to End- Point Security Policies » Advanced QoS and traffic prioritization options » Rugged D38999 connectors » Auto-switching 110-240VAC, 47-440Hz & 18-36VDC FIPS 140-2 Compliant Newtec, iDirect, Comtech or Teledyne Paradise Datacom Satellite Network Compatible Electrical & EMI/EMC Test » MIL-STD-461G & RTCA/DO-160G » Magnetic Effect, Section 15 » Power Input, Section 16 » Voltage Spikes, Section 17 » Induced Signal Susceptibility, Section 19 » RF Conducted Susceptibility, I/O Cables & Power Leads, Section 20 » RF Conducted Susceptibility, Antenna/RF Port, CS104 » Conducted Susceptibility, Bulk Cable Injection, Impulse Excitation, CS115 » Conducted Susceptibility, Damped Sinusoidal Transients, CS116 » RF Radiated Susceptibility, Section 20 » RF Conducted Emissions, I/O Cables & Power Leads, Section 21 » RF Conducted Emissions, Antenna/RF Port, CE106 » RF Radiated Emissions, Section 21 » Lightning, Section 22 » Aircraft Electrical Power Characteristics per MIL-STD-704 Environmental Test » MIL-STD-810G & RTCA/DO-160G » Low Pressure (Altitude) » High and Low Temperature » Temperature Variation » Solar Radiation » Dust & Waterproofness (IP66) » Humidity » Blowing Sand and Dust » Vibration » Shock » Combined Environment (Temperature/Altitude/Humidity) Platform, Frequency Band, and Application Agnostic Connectivity NEMESIS satellite communications (SATCOM) router can be seamlessly integrated with multiple antenna platforms and frequncy band variants (X, C, Ku, Ka). Whether on land, air, or sea, NEMESIS SATCOM router provides highly efficient, dependable, secure, high throughput two-way transmission of video, voice, and data. Designed for Mobility Leveraging the Open AMIP protocol and network platform embedded mobility manager feature, NEMESIS SATCOM router is able to interface with ultra-small and phased-array antennas on aircraft as well as three axis stabilized antennas on marine and COTM land based platforms. These features allow for seamless automatic antenna pointing and beam switching functionality. Flexible and Optimized Service Performance NEMESIS supports a wide array of Modulation and Coding (MODCOD) schemes utilizing industry proven DVB-S2 standards in conjunction with S2 extensions and Flexible Adaptive Coding and Modulation (FlexACM) on the forward carrier. On the return path, NEMESIS supports MF-TDMA, SCPC (HRC/S2), and MxTDMA return access technologies empowering users with the flexibility to target the Advanced filtering technology and improved roll-off options (as low as 5%) provide immediate cost savings due to optimum satellite spectrum efficiency. Additionally, incorporated IP traffic enhancement software for TCP acceleration, pre- fetching, and compression. Enhanced Security NEMESIS provides worry-free communications over any trusted or untrusted network. Network traffic is secured via flat layer-2 encrypted (AES 128, 192, 256) tunnels using unique RSA keys and Diffie- Hellman key exchange authentication. NEMESIS method of mandatory, mutual authentication eliminates the possibility of an attacker entering network sessions via identity spoofing or a man-in-the-middle attack.

Transcript of NEMESIS · can be seamlessly integrated with multiple antenna platforms and frequncy band variants...

Page 1: NEMESIS · can be seamlessly integrated with multiple antenna platforms and frequncy band variants (X, C, Ku, Ka). Whether on land, air, or sea, NEMESIS SATCOM router provides highly

KNOW 2 SOLUTIONS

KNOW 2 SOLUTIONS | 3956 MERLIN DRIVE, KISSIMMEE, FLORIDA 34741 | 407.750.9749

CAGE CODE 6QEK4 | DUNS 078405039 | [email protected] | WWW.KNOW2SOLUTIONS.COM

NEMESISNETWORKED ETHERNET MODULATED ENCRYPTION SECURE INFORMATION SYSTEM

Key Features » Certified to MIL-STD Environmental,

and EMI for air, land and sea

» 4CPM/MF-TDMA, HRC/Mx-DMA, and HRC/S2 SCPC return topologies supported

» 5, 10, 15, 20, 25 and 35% Roll-Offs supported

» High performance concurrent unicast service rates up to 100/25 Mbps

» Transmit multicast up to 85 Mbps

» Receive multicast support (IGMPv2 / static configuration) up to 200Mbps

» VL-SNR support for extended availability and PSD restricted applications

» DNS Cache/Relay, TCP Acceleration and Compression, and HTTP pre-fetching

» Multi-level Quality of Service with seven Quality of Service Classes

» Automatic Uplink Power Control and ACM

» Protocol-independent Layer 2 Tunneling

» TRANSEC security and Hardware Accelerated AES 256-bit encryption

» Pre-placed Public Key (PPPK) Two-Factor Authentication

» Dynamic Updates to End-Point Security Policies

» Advanced QoS and traffic prioritization options

» Rugged D38999 connectors

» Auto-switching 110-240VAC, 47-440Hz & 18-36VDC

FIPS 140-2 Compliant

Newtec, iDirect, Comtech or Teledyne Paradise Datacom Satellite Network Compatible

Electrical & EMI/EMC Test » MIL-STD-461G & RTCA/DO-160G

» Magnetic Effect, Section 15

» Power Input, Section 16

» Voltage Spikes, Section 17

» Induced Signal Susceptibility, Section 19

» RF Conducted Susceptibility, I/O Cables & Power Leads, Section 20

» RF Conducted Susceptibility, Antenna/RF Port, CS104

» Conducted Susceptibility, Bulk Cable Injection, Impulse Excitation, CS115

» Conducted Susceptibility, Damped Sinusoidal Transients, CS116

» RF Radiated Susceptibility, Section 20

» RF Conducted Emissions, I/O Cables & Power Leads, Section 21

» RF Conducted Emissions, Antenna/RF Port, CE106

» RF Radiated Emissions, Section 21

» Lightning, Section 22

» Aircraft Electrical Power Characteristics per MIL-STD-704

Environmental Test » MIL-STD-810G & RTCA/DO-160G

» Low Pressure (Altitude)

» High and Low Temperature

» Temperature Variation

» Solar Radiation

» Dust & Waterproofness (IP66)

» Humidity

» Blowing Sand and Dust

» Vibration

» Shock

» Combined Environment (Temperature/Altitude/Humidity)

Platform, Frequency Band, and Application Agnostic ConnectivityNEMESIS satellite communications (SATCOM) router can be seamlessly integrated with multiple antenna platforms and frequncy band variants (X, C, Ku, Ka). Whether on land, air, or sea, NEMESIS SATCOM router provides highly efficient, dependable, secure, high throughput two-way transmission of video, voice, and data.

Designed for MobilityLeveraging the Open AMIP protocol and network platform embedded mobility manager feature, NEMESIS SATCOM router is able to interface with ultra-small and phased-array antennas on aircraft as well as three axis stabilized antennas on marine and COTM land based platforms. These features allow for seamless automatic antenna pointing and beam switching functionality.

Flexible and Optimized Service PerformanceNEMESIS supports a wide array of Modulation and Coding (MODCOD) schemes utilizing industry proven DVB-S2 standards in conjunction with S2 extensions and Flexible Adaptive Coding and Modulation (FlexACM) on the forward carrier. On the return path, NEMESIS supports MF-TDMA, SCPC (HRC/S2), and MxTDMA return access technologies empowering users with the flexibility to target the Advanced filtering technology and improved roll-off options (as low as 5%) provide immediate cost savings due to optimum satellite spectrum efficiency. Additionally, incorporated IP traffic enhancement software for TCP acceleration, pre-fetching, and compression.

Enhanced SecurityNEMESIS provides worry-free communications over any trusted or untrusted network. Network traffic is secured via flat layer-2 encrypted (AES 128, 192, 256) tunnels using unique RSA keys and Diffie-Hellman key exchange authentication. NEMESIS method of mandatory, mutual authentication eliminates the possibility of an attacker entering network sessions via identity spoofing or a man-in-the-middle attack.

Page 2: NEMESIS · can be seamlessly integrated with multiple antenna platforms and frequncy band variants (X, C, Ku, Ka). Whether on land, air, or sea, NEMESIS SATCOM router provides highly

KNOW 2 SOLUTIONS | 3956 MERLIN DRIVE, KISSIMMEE, FLORIDA 34741 | 407.750.9749

CAGE CODE 6QEK4 | DUNS 078405039 | [email protected] | WWW.KNOW2SOLUTIONS.COM

Satellite ConfigurationFORWARD CARRIER (RX)

» Standard: DVB-S2 / DVB-S2X ACM » Modulation: QPSK, 8PSK,

16APSK, 32APSK, 64APSK » Roll-off: 5, 10, 15, 20, 25 and 35% » Symbol Rate: 1-500 Mbaud

(MODCOD Limitations Apply)

RETURN CARRIER (TX)4CPM / MF-TDMA

» Modulation: 4CPM and 6 MODCODs » Channel bandwidth: 128kHz to 4 MHz

HRC / Mx-DMA » Modulation: QPSK up-to

32APSK with 50 MODCODs » Roll-off: 5% » Symbol Rate: 30kBaud - 20 Mbaud

S2 / SCPC » Standard: DVB-S2 ACM (short/normal

frames) S2 Extensions (normal frames) » Modulation: QPSK, 8APSK,

16APSK, 32APSK, 64APSK » Roll-off: 5, 10, 15, 20, 25 and 35% » Symbol Rate: 1-40 Mbaud

InterfacesRF OUTPUT (TX / BUC Interface)

» Connector: BNC » Impedance: 75 Ohm (50 Ohm) » Frequency: 950-2400 MHz » TX Level: -55 to +5 dBm » Ref Signal: 10 MHz » BUC PSU: 24VDC, 3A

RF INPUT (RX / LNB Interface) » Connector: TNC » Impedance: 75 Ohm (50 Ohm) » Frequency: 950-2150 MHz » RX Level: -65 to -25 dBm » Ref Signal: 10MHz » LNB PSU: 13/18VDC, 500mA

BASEBAND » LAN Connector: D38999 connector

providing 3 unsecure direct modem interfaces and five secure TRANSEC Single Board Computer (TSBC) Interfaces via internal ethernet switch.

» LAN Speed/Duplex: 10/100 Full » Remote Interface: High Density

D-Sub connector providing remote LED status, token key (USB) interface, and System ON/OFF

» USB: One direct interface to TSBC board and one direct interface to modem board (future use)

» Reset Connector: Discrete two pin D38999 (factory reset of modem board)

Internal Components & Features » Embedded Intel® Core™ i7 Based Server » Embedded 8-port Managed Ethernet Switch

IP FEATURES » Protocols: UDP, IPv4 & IPv6,

ICMP, IGMPv2, TCP, ARP, DHCP, DNS, NTP, DiffServ Marking

SECURITY FEATURES » Data Integrity: SHA-256, HMAC SHA-1 » Encryption Algorithm: AES128, 192, 256 » Public Key Cryptography: RSA and Diffie-

Hellman, 512, 1024, 2048, 4096 RSA Keys

Mechanical/EnvironmentalPHYSICAL SPECIFICATIONS

» Size: W 18.98” x D 21.85” x H 1.747” » Weight: 18.8 lbs / 8.52 kg

POWER SPECIFICATIONS » Input Voltage: Auto-select 18-36VDC,

and 110-240VAC, 47-440Hz, 1Ø » Power Consumption: DC: 11 Amps

AC: 3 Amps

ENVIRONMENTAL SPECIFICATIONS » Operating Temp.: -40ºC to +60ºC » Altitude: Up to 40,000 ft.

Up to 60,000 ft. (Optional) » Humidity: Up to 95% RH non-

condensing operational, 100% condensing storage

Additional Features & Options » Modulated Encryption using TRANSEC » Industry standard Antenna Control

Unit (ACU) management interface (Open AMIP standard)

» Over-the-air software & configuration updates

» Over-the-air monitoring, self-test and diagnostics

» Standard 1RU Remote Panel Interface includes all status indicators, remote ON/OFF switch and USB Interface.

» Optional D38999 LAN interface to RJ-45 1RU breakout panel or breakout cable

» Customization available upon request

3959 Merlin DriveKissimmee, FL 34741(407) 750-9749

FRONT VIEW SIDE VIEW REAR VIEW

TOP VIEW

J1 - POWER INPUT(18-36VDC / 110-220VAC 47-440Hz)

MS3102R18-11P

J2 - RXTNC FEMALE

J3 - TXBNC FEMALE

J5 - MAINTENANCED38999/20WD35SA

E E

D

NOTES:

J4 - ETHENRETD38999/20WD35SN

REV. C