NEMA Contactors and Starters - Grainger Industrial Supply · PDF fileVolume 5—Motor...

Click here to load reader

  • date post

    03-Apr-2018
  • Category

    Documents

  • view

    242
  • download

    4

Embed Size (px)

Transcript of NEMA Contactors and Starters - Grainger Industrial Supply · PDF fileVolume 5—Motor...

  • Volume 5Motor Control and Protection CA08100006EJanuary 2013 www.eaton.com V5-T2-1

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    NEMA Contactors and Starters

    NEMA AN16DN0ABNEMA Size 1 Starter

    NEMA Size 1 Contactor

    2.1 Freedom SeriesProduct Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V5-T2-2Features, Benefits and Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . V5-T2-2Standards and Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V5-T2-3Catalog Number Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V5-T2-3ContactorsNon-Reversing and Reversing . . . . . . . . . . . . . . . . . . . . . V5-T2-4StartersThree-Phase Non-Reversing and Reversing,

    Full Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V5-T2-10StartersSingle-Phase Non-Reversing, Full Voltage,

    Bi-Metallic Overload . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V5-T2-15Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V5-T2-21Renewal Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V5-T2-30Technical Data and Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . V5-T2-34RelaysThermal Overload . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V5-T2-38C440/XT Electronic Overload Relay . . . . . . . . . . . . . . . . . . . . . . . . . . . V5-T2-48

    2.2 A200 Series ContactorsNon-Reversing and Reversing . . . . . . . . . . . . . . . . . . . . . V5-T2-65StartersNon-Reversing and Reversing . . . . . . . . . . . . . . . . . . . . . . . V5-T2-71RelaysThermal and Fast Trip . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V5-T2-92Thermal Type B, Class 20, Manual Reset . . . . . . . . . . . . . . . . . . . . . . . V5-T2-94Thermal Type A, Class 20, Auto/Manual Reset. . . . . . . . . . . . . . . . . . . V5-T2-97Type FT Fast Trip, Class 10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V5-T2-100Heater Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V5-T2-103RelaysCurrent Sensing Protective. . . . . . . . . . . . . . . . . . . . . . . . . . . V5-T2-105

    2.3 SolenoidsAlternating CurrentProduct Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V5-T2-108Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V5-T2-108Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V5-T2-109Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V5-T2-110

    2.4 Shoe BrakesAC and DC MagneticProduct Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V5-T2-111Application Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V5-T2-111Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V5-T2-111Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V5-T2-112Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V5-T2-114

    2.5 Reference DataIEC Utilization Categories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V5-T2-116Annex A (informative) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V5-T2-117Motor Ratings Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V5-T2-119

    DrawingsOnline

  • V5-T2-2 Volume 5Motor Control and Protection CA08100006EJanuary 2013 www.eaton.com

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2.1 NEMA Contactors and StartersFreedom Series

    Freedom Series ContentsDescription Page

    Technical Data and SpecificationsStandards and Certifications . . . . . . . . . . . . . . . V5-T2-3Catalog Number Selection . . . . . . . . . . . . . . . . V5-T2-3ContactorsNon-Reversing and Reversing . . . V5-T2-4StartersThree-Phase Non-Reversing and

    Reversing, Full Voltage . . . . . . . . . . . . . . . . . . V5-T2-10StartersSingle-Phase Non-Reversing,

    Full Voltage, Bi-Metallic Overload . . . . . . . . . . V5-T2-15Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . V5-T2-21Renewal Parts . . . . . . . . . . . . . . . . . . . . . . . . . . V5-T2-30Technical Data and Specifications . . . . . . . . . . . V5-T2-34RelaysThermal Overload . . . . . . . . . . . . . . . . V5-T2-38C440/XT Electronic Overload Relay . . . . . . . . . V5-T2-48

    Product OverviewFreedom Series starters and contactors feature a compact, space-saving design, using state-of-the-art technology and the latest in high strength, impact and temperature resistant insulating materials.

    Features, Benefits and FunctionsFreedom NEMA Adjustable bimetallic

    ambient compensated overload relays with interchangeable heater packsavailable in three basic sizes, covering applications up to 900 hpreducing the number of different contactor/overload relay combinations that have to be stocked. Fixed heater overloads are optional

    Electronic overload relay (C440) available as a stand-alone unit and assembled with Freedom Contactor

    A full line of snap-on accessories top and side mounted auxiliary contacts, solid-state and pneumatic timers, and so on

    Straight-through wiringline lugs at top, load lugs at bottom

    Horizontal or vertical mounting on upright panel for application freedom

    Screw type power terminals have captive, backed-out self-lifting pressure plates with screwsreduced wiring time

    Accessible terminals for easy wiring. Optional fingerproof shields available to prevent electrical shock

    Top located coil terminals convenient and readily accessible. 45 mm contactor magnet coils have three terminals, permitting either top or diagonal wiringeasy to replace European or U.S. style starters or contactors without changing wiring layout

    Designed to meet or exceed NEMA, UL, CSA, VDE, BS and other international standards and listings

    American engineeringbuilt by Eaton, using the latest in statistical process control methods to produce high quality, reliable products

    Sized based on standard NEMA classifications

    Easy coil change and inspectable/replaceable contacts

    Available in open and NEMA Type 1, 3R, 4/4X and 12 enclosures

  • Volume 5Motor Control and Protection CA08100006EJanuary 2013 www.eaton.com V5-T2-3

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2.1NEMA Contactors and StartersFreedom Series

    Standards and Certifications Standard: designed to

    meet or exceed UL, NEMA, IEC, CSA, VDE and BS

    UL listed: UL File #E1491, Guide #NLDXOpen and NEMA 1, 4, 12 Enclosed

    CSA Certified: CSA File #LR353, Class #321104 Open and NEMA 1 Enclosed

    ISO 9000 CertificationWhen you turn to Eatons products, you turn to quality. The International Standards Organization (ISO) has established a series of standards acknowledged by 91 industrialized nations to bring harmony to the international quest for quality. The ISO certification process covers 20 quality system elements in design, production and installation that must conform to achieve registration. This commitment to quality will result in increased product reliability and total customer satisfaction.

    Short Circuit ProtectionFuses and Inverse-Time Circuit Breakers may be selected per Article 430, Part D of the National Electrical Code to protect motor branch circuits from fault conditions. If higher ratings or settings are required to start the motor, do not exceed the maximum as listed in Exception No. 2, Article 430-52.

    Catalog Number Selection

    Freedom Series

    Notes1 For contactor only orders, add B to end of catalog number if NEMA Size 002, 6.2 NEMA Sizes 00 and 0 only.3 NEMA Sizes 00 and 0 only. Sizes 18 are 24/60 only.4 NEMA Size 5 requires the use of CTs with 1-5A OL relay.

    A N 1 9 A N 0 A 5E 005

    Device TypeA = StarterC = Contactor

    Contactor Frame Size 1

    NEMA Size

    Continuous Amperes

    A=B=D=G=K=N=S=T=U=V=

    00012345678

    9182745901352705408101215

    Device Assembly Configuration

    70 = Multi-speed1 = Non-reversing5 = Reversing

    StandardE = IECN = NEMA

    C440 FLA Range(FVNR and FVR only)

    NEMA Size 00 1P6 = 0.331.65A005 = 15A020 = 420ANEMA Size 01P6 = 0.331.65A005 = 15A020 = 420ANEMA Size 11P6 = 0.331.65A005 = 15A020 = 420A045 = 945ANEMA Size 2005 = 15A020 = 420A045 = 945ANEMA Size 3100 = 20100A NEMA Size 4140 = 28140A NEMA Size 5 4

    300 = 60300A

    AC Coil SuffixSuffix Coil Volts and HertzA BCDEHJ K L N T U V W Y

    = 120/60 or 110/50= 240/60 or 220/50= 480/60 or 440/50= 600/60 or 550/50= 208/60= 277/60= 208 240/60 2= 240/50= 380 415/50= 550/50= 24/60, 24/50 3= 24/50= 32/50= 48/60= 48/50

    C440 OLR Designation(FVNR and FVR only)

    5E = Standard feature set SEL Reset, SEL Class (10A, 10, 20, 30)

    5G = Ground fault feature set SEL Reset, SEL Class