30
NEEDLE DETECTION PROCEDURES AND SHARP TOOL CONTROL Factory name: MANGO VID#: 11277

Transcript of Needle broken procedure sample

Page 1: Needle broken procedure sample

NEEDLE DETECTION PROCEDURES

AND SHARP TOOL CONTROL

Factory name: MANGOVID#: 11277

Page 2: Needle broken procedure sample

NEEDLE DETECTION PROCEDURE

PART :I

Page 3: Needle broken procedure sample

1.0 mm diameter test card supplied with unit

Needle Detector Calibration Card (NDCC) are used to calibrate the machine

Page 4: Needle broken procedure sample

Sensitivity level must be adjusted over 50

Page 5: Needle broken procedure sample

Needle detector operators list and procedures in native language

Page 6: Needle broken procedure sample

A Nine-Points Calibration box andNeedle Detector Calibration Card

Page 7: Needle broken procedure sample

Nine-Points Calibration Recordsand Needle Calibration Logs

Page 8: Needle broken procedure sample

Garments pass through the detector before packing (using two needle detectors)

Page 9: Needle broken procedure sample

Factory uses two needle detector to scan front and back garment

Page 10: Needle broken procedure sample

When the alarm sounds the garment must be put to one side in a clearly marked area, and a designated operator must check the

garment for contamination

Page 11: Needle broken procedure sample

All of contaminated garments must be put into the Contaminated box before hand

held detection

Page 12: Needle broken procedure sample

Use hand held detector to locate contamination on the garment

Page 13: Needle broken procedure sample

Passed garments must be kept in a identified area inside metal free zone, and proceed to packing after pass next calibration for needle detector

Page 14: Needle broken procedure sample

CCTV

Page 15: Needle broken procedure sample

Broken needle procedure in English

Page 16: Needle broken procedure sample

Broken needle procedure in native language

Page 17: Needle broken procedure sample

Any broken and blunt needle must be logged in the garment defected records for

contamination

Page 18: Needle broken procedure sample

Missing broken needle/metal/sharp tool policy (4 steps)

Use small/big magnet device to check whole working area, on surface, inside machine and on the ground in place with radius around 1 meter.

Step 1

Page 19: Needle broken procedure sample

Use handheld detector to check whole doing operation of the panel and the bundle

Step 2

Page 20: Needle broken procedure sample

Pass panel/ bundle through metal detector. Share information to Finishing manager of the issue.

Step 3

Page 21: Needle broken procedure sample

In case, broken needle is unable to be found, needle controller make report, inform to General director/AQM/Pro Manager/Finishing manager. Record of contamination. Keep the piece in RED BOX. Finally, give new needle to sewer with correct size and type of needle.

Step 4

Page 22: Needle broken procedure sample

SHARP TOOL CONTROL

PART :II

Page 23: Needle broken procedure sample

FABRIC WAREHOUSE/QC

Page 24: Needle broken procedure sample

CUTTING

Page 25: Needle broken procedure sample

CUTTING

CUTTING EQUIPMENT CONTROL LOG

Page 26: Needle broken procedure sample

SEWING

Page 27: Needle broken procedure sample

SEWING

TIED SCISSORS IN SEWING SEWING SCISSORS

Page 28: Needle broken procedure sample

MACHANIC AREA

NEDDLE CONTROLL BOOK

Page 29: Needle broken procedure sample

FINISHING AREA

TAG GUN

TAG GUN CONTROL AREA

TAG GUN CONTROL LOG

Page 30: Needle broken procedure sample

FINISHING AREA

TAPE DISPENSER WITH WORKERS’NAME