Natural Light in DesignNatural Light in Design · 173 Design Practitioners (over 80% using LEED)...

13
Natural Light in Design Natural Light in Design Using simulation tools to explore realistic daylight- responsive solutions Using simulation tools to explore realistic daylight- responsive solutions Christoph Reinhart, Ph.D. Christoph Reinhart, Ph.D. Static Daylighting Metrics Static Daylighting Metrics Daylight Factor Visual Comfort Daylight Autonomy Avoidance of Direct Sunlight

Transcript of Natural Light in DesignNatural Light in Design · 173 Design Practitioners (over 80% using LEED)...

Page 1: Natural Light in DesignNatural Light in Design · 173 Design Practitioners (over 80% using LEED) choose 0 Architectural Building energy consumption Load management Lighting Cost energy

Natural Light in DesignNatural Light in DesignUsing simulation tools to explore realistic daylight-responsive solutionsUsing simulation tools to explore realistic daylight-responsive solutions

Christoph Reinhart, Ph.D.Christoph Reinhart, Ph.D.Static Daylighting MetricsStatic Daylighting Metrics

Daylight Factor Visual Comfort

Daylight Autonomy Avoidance of Direct Sunlight

Page 2: Natural Light in DesignNatural Light in Design · 173 Design Practitioners (over 80% using LEED) choose 0 Architectural Building energy consumption Load management Lighting Cost energy

Overview – Static Daylighting Metrics

Page 3: Natural Light in DesignNatural Light in Design · 173 Design Practitioners (over 80% using LEED) choose 0 Architectural Building energy consumption Load management Lighting Cost energy

Objectives for this module

• Discuss daylighting design intentions

• Introduce some daylight performance metrics

Page 4: Natural Light in DesignNatural Light in Design · 173 Design Practitioners (over 80% using LEED) choose 0 Architectural Building energy consumption Load management Lighting Cost energy

What is good daylighting?

Page 5: Natural Light in DesignNatural Light in Design · 173 Design Practitioners (over 80% using LEED) choose 0 Architectural Building energy consumption Load management Lighting Cost energy

Context I

LEED and Green Globe provide daylight credits for:

daylight factor

view to the outside

specification of shading devices (Green Globe only)

Compliance is verified via spreadsheet method.

Page 6: Natural Light in DesignNatural Light in Design · 173 Design Practitioners (over 80% using LEED) choose 0 Architectural Building energy consumption Load management Lighting Cost energy

Context II- What is Daylighting?173 Design Practitioners (over 80% using LEED) choose

0Architectural Building energy

consumptionLoad

managementCostLighting

energy savings

10

20

30

40

Which of the Following Definitions for Daylighting is the Most Relevant to you?

50

Engineers & Energy ConsultantsDesigners (Lighting Designers, Architects, Interior Designers)

Figure by MIT OCW.

Page 7: Natural Light in DesignNatural Light in Design · 173 Design Practitioners (over 80% using LEED) choose 0 Architectural Building energy consumption Load management Lighting Cost energy

Context III- What is Daylighting?Architectural definition: the interplay of natural light and building form to provide a visually stimulating, healthful, and productive interior environmentLighting Energy Savings definition: the replacement of indoor electric illumination needs by daylight, resulting in reduced annual energy consumption for lightingBuilding Energy Consumption definition: the use of fenestration systems and responsive electric lighting controls to reduce overall building energyrequirements (heating, cooling, lighting) Load Management definition: dynamic control of fenestration and lighting to manage and control building peak electric demand and load shape

Cost definition: the use of daylighting strategies to minimize operating costs and maximize output, sales, or productivity

**

*

Do daylight factor & view LEED to good daylighting?

Page 8: Natural Light in DesignNatural Light in Design · 173 Design Practitioners (over 80% using LEED) choose 0 Architectural Building energy consumption Load management Lighting Cost energy

Daylight Factor DefinitionDF = (E point/E outside horizontal) * 100%

The DF is only defined under overcast skies!

E outside horizontal

E point

Figure by MIT OCW.

Page 9: Natural Light in DesignNatural Light in Design · 173 Design Practitioners (over 80% using LEED) choose 0 Architectural Building energy consumption Load management Lighting Cost energy

Historical Background: “Right of Light”

Waldram 1945Waldram 1945

UK Prescription Act (1832): If one has benefited from daylight access across some else's property for over 20 years, an absolute and indefeasible ‘rights to light’ is granted to the building.

Page 10: Natural Light in DesignNatural Light in Design · 173 Design Practitioners (over 80% using LEED) choose 0 Architectural Building energy consumption Load management Lighting Cost energy

Daylight Factor Use in Design

Pro:intuitive quantityovercast sky as a worst case scenariovenetian blinds (even if closed) still admit sufficient DL

7%

3,5%

0%

Page 11: Natural Light in DesignNatural Light in Design · 173 Design Practitioners (over 80% using LEED) choose 0 Architectural Building energy consumption Load management Lighting Cost energy

Daylight Factor – design implications Iwindow head height ⟨reference

glazing type ⟨ narrow floor plan ⟨

Page 12: Natural Light in DesignNatural Light in Design · 173 Design Practitioners (over 80% using LEED) choose 0 Architectural Building energy consumption Load management Lighting Cost energy

Daylight Factor – design implications IIThe daylight factor optimized building is fully glazed.

Note, there are LEED certified buildings that are fully glazed!

Page 13: Natural Light in DesignNatural Light in Design · 173 Design Practitioners (over 80% using LEED) choose 0 Architectural Building energy consumption Load management Lighting Cost energy

Avoidance of Direct Sunlightoptimized for static shading devicelouvers, lightshelves etc. ⟨

Resulting building design form good from an energy standpoint.