NATURAL DAYLIGHT SOLUTIONS - Glidevale · most people prefer a working environment with daylight to...

16
................................................................... NATURAL DAYLIGHT SOLUTIONS CI/SfB (37.4) Uniclass L414 July 2012 New low profile glazing .................... ....................

Transcript of NATURAL DAYLIGHT SOLUTIONS - Glidevale · most people prefer a working environment with daylight to...

Page 1: NATURAL DAYLIGHT SOLUTIONS - Glidevale · most people prefer a working environment with daylight to one without. It references ... Health and Wellbeing Section HW01 and the Energy

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

NATURAL DAYLIGHT SOLUTIONS

CI/SfB (37.4)Uniclass L414July 2012

Newlow profile

glazing

. . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . .

Page 2: NATURAL DAYLIGHT SOLUTIONS - Glidevale · most people prefer a working environment with daylight to one without. It references ... Health and Wellbeing Section HW01 and the Energy

NATURAL DAYLIGHT SOLUTIONS

. . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .NATURAL DAYLIGHTING

SustainabilityThe sun is a sustainable light source, andnatural daylight can make a significantcontribution to sustainable building design.Rooflights are an effective and efficientmeans of maximising natural daylight indark areas, often virtually eliminating theneed for supplementary electric lightingduring the day.

Glidevale natural daylight systems, used as acomplement to artificial lighting, canconsiderably reduce the annual energyconsumption of any building, therebyreducing CO2 emissions.

Proven benefits of natural lightScientific studies have shown the positivebenefits of natural daylight for health andwellbeing in a range of applications.

The CIBSE Office Lighting Guide states thatNatural Daylight is an almost universalworker requirement. When given a choice,most people prefer a working environmentwith daylight to one without. It referencesdocumented evidence confirming thatexcluding daylight leads to increasednumbers of complaints about the workingenvironment, and may adversely affectproductivity. The Daylight WorkplaceRegulations state that “The lighting in everyworkplace shall, as far as is reasonablypractical, be by natural light.”

BRE Environmental Assessment MethodThe benefits of natural daylighting arerecognised by the Building ResearchEstablishment (BRE) EnvironmentalAssessment Method (BREEAM).

BREEAM Modules cover Schools, Offices,Healthcare, Retail and Industrial buildings.These buildings are then rated on a scale ofPASS, GOOD, VERY GOOD or EXCELLENT.Glidevale natural daylight systems cancontribute to the credits available under theHealth and Wellbeing Section HW01 and theEnergy Section E01.

Glidevale market a range of naturaldaylighting products includingtubular rooflights, conventional

rooflights, combined rooflight/ventilatorsand hybrid lighting systems.

Advantages● Highly effective at delivering light into

internal and badly-lit spaces withoutwindows.

● Energy saving - reduces the need for artificial lighting and helps reduce carbonfootprint.

● Wide range of applications - houses, flats,schools, hospitals, commercial, industrialbuildings, care homes, nursing homes andstudent accommodation.

● Suitable for both new-build andrefurbishment projects.

● Meet the thermal requirements of the latest building regulations.

● Hybrid natural and artificial lighting solutions.

Page 3: NATURAL DAYLIGHT SOLUTIONS - Glidevale · most people prefer a working environment with daylight to one without. It references ... Health and Wellbeing Section HW01 and the Energy

NATURAL DAYLIGHT SOLUTIONS

. . . . . . . . . . . . . . . . . . . . . . . . . .

3

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

PRODUCT RANGE

Sunscoop™ tubular rooflightsUsed to bring natural daylight into internalrooms and spaces that have no, orinsufficient, windows. Natural daylightenters through a roof-mounted low profileglazing unit or skylight and is reflected downa mirrored tube/duct and into the roombelow through a ceiling-mounted diffuser.Particularly useful for rooms and spacesbelow another room or a pitched roof. Alsoavailable with occupant sensor and adaylight controller for integrated low energyartificial lighting.A combined light and ventilation unit(Sunscoop iPSV) is also available.

Sunscoop hybridA unique, automatic and energy savingsystem combining natural daylight andluminaire to achieve more consistentilluminance irrespective of externalconditions

Metrodome modular rooflightsAn all-aluminium rooflight and access hatchrange offering ventilation options andthermal efficiency. Designed for both newbuild and refurbishment applications.Particularly suitable for refurbishment, sincenon standard sizes can be made to suitexisting roof openings and kerbs.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Natural daylighting 2

Product range 3

Sunscoop tubular rooflight systems 4

Sunscoop iPSV light & ventilation 10

Sunscoop hybrid 11

Metrodome modular rooflights 12

Metroglazing replacement units 15

Further information 16

Page 4: NATURAL DAYLIGHT SOLUTIONS - Glidevale · most people prefer a working environment with daylight to one without. It references ... Health and Wellbeing Section HW01 and the Energy

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4

Sunscoop™ Tubular Rooflight systems areused to bring natural daylight into

internal rooms and spaces that have no, orinsufficient, windows.

Sunscoop Tubular Rooflights consist of aroof-mounted clear polycarbonate lowprofile glazing unit or skylight connected toa tube with an internal mirrored finish with98% reflectance. Natural daylight enters theglazing unit or skylight and is reflecteddown the tube and into the room through aceiling-mounted diffuser.

Sunscoop advantages● Highly effective at delivering light into

internal and poorly lit spaces.

● System design and performance are backedby an unrivalled programme of research.

● Energy saving - reduces the need forartificial lighting and helps reduce carbonfootprint.

● Natural daylight has positive benefits overartificial lighting.

● Wide range of applications - houses, flats,schools, hospitals, commercial andindustrial buildings.

● Range of sizes for different requirements.

● Simple and reliable installation.

● Can be used on pitched and flat roofs.

● Adjustable elbows give flexibility of sitingon tubular systems.

● Complete system meets the thermalrequirements of the latest buildingregulations.

● Sunscoop daylighting performancesoftware calculations available.

● Sunscoop Hybrid systems available,combining natural and artificial lightingwith integrated intelligent controllers.

Silsoe Research Institute report

Page 5: NATURAL DAYLIGHT SOLUTIONS - Glidevale · most people prefer a working environment with daylight to one without. It references ... Health and Wellbeing Section HW01 and the Energy

NATURAL DAYLIGHT SOLUTIONS

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SUNSCOOP™ TUBULAR ROOFLIGHT SYSTEMS

Internal view of differentdiameter tubularrooflights under test

Monitoring of threetubular rooflightssimultaneously

External lux sensor withshade ring for measuringdiffused light levels

PERFORMANCE

Unique test programmeThe performance of the Sunscoop TubularRooflight system has been firmly establishedby a unique and extensive period of testing,unparalleled in the tubular rooflightindustry, carried out by Silsoe ResearchInstitute (SRI) and BPD. Measurements weretaken over four to six month periods duringthe summer/ autumn in all natural lightconditions ranging from bright clear skies toovercast conditions.

This comprehensive monitoring has for thefirst time provided accurate, realistic andreliable performance data for tubularrooflight systems including direct anddiffuse lighting conditions.

The research is subject of a published paperentitled ‘Optimisation & design of ducteddaylight systems: 2010’ which is specific toGlidevale systems only.

Typical light levelsThe light output from the Sunscoop systemdepends on the size and length of tubing,offset angles if any, the external skyconditions and light levels measured in lux.

The distribution of the light in the roomdepends on the diffuser type and the wall,ceiling and floor reflectances.

A sophisticated in house computerprogramme has since been developed toaccurately predict light levels of Sunscoopsystems, based directly on the SRI and BPDmonitoring.

System layoutSunscoop systems can pass through a roofspace or other void.

For maximum effectiveness the tubingshould be as straight as possible. However,since it is often impractical to site the ceilingdiffuser directly below the roof-mountedglazing, the tubing system allows an offsetby means of an elbow. It is adjustable up to30º from vertical.

Other elbows can be used but monitoringhas shown that these will adversely affectperformance.

SitingWhere possible the roof-mounted glazingshould be located on a south-facing slope togain the maximum amount of daylightunder both direct and diffuse conditions.

Factors which need to be considered whensiting a Sunscoop include:

- Location of the room to be lit and suitableposition of the ceiling diffuser.

- Roof space obstructions.

- Proximity of other buildings, trees etc,which may cast shadows at certain timesof the day or year.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 6: NATURAL DAYLIGHT SOLUTIONS - Glidevale · most people prefer a working environment with daylight to one without. It references ... Health and Wellbeing Section HW01 and the Energy

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .SUNSCOOP™ TUBULAR INSTALLATION

NATURAL DAYLIGHT SOLUTIONS

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

. . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . .

Site-fabricated insulated upstand

For more information on installation details pleasecontact Glidevale Technical Services.

Sunscoop on pitched roof

Roof flashing withAluFlash attached

Traditional skylight, polyesterpowder coated aluminium framewith polycarbonate glazing

98% reflective tubing

98% reflective tubing

Square to round adaptorwith integral elbow

Sunscoop on standing seam roof

Adjustable elbow to 30°

Sunscoop on flat roofLow profilepolycarbonate glazing

Insulation by others

Ceiling diffuser

98% reflective tubingwith insulation

Single skin aluminiumupstand

Insulation by others

Low profilepolycarbonate glazing

Page 7: NATURAL DAYLIGHT SOLUTIONS - Glidevale · most people prefer a working environment with daylight to one without. It references ... Health and Wellbeing Section HW01 and the Energy

NATURAL DAYLIGHT SOLUTIONS

. . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

. . . . . . . . . . . . . . . . . . . . . . . . . .

Specification clause

Natural daylight to …rooms to be provided bymeans of GlidevaleSunscoop tubular ductedsystems comprising:Roof-mounted low profileglazing of 3.0mm clearuv-stabilisedpolycarbonate covered by10-year warranty againstloss of impact strength,excessive yellowing andloss of light transmission.Roof interface flashing tobe ... To have AA fire rating toBS 476: Part 3; 2004.Tubes and elbows to beSR98 Mirror withreflectance 98% and 25-year warranty. System diameter: 250mm/ 350mm / 450mm /530mm.*Circular recessed ceilingdiffuser of diffusedpolycarbonate with white-capped ABS ceiling ring /chrome / brass effect /Skyview diffuser circular /Skyview diffuser square.*Options to be fitted:Polycarbonate secondaryglazing skin, integralelectric light fitting, light-attenuating damper, fireprotection collar.*All exposed tubes andelbows within unheatedvoids to be wrapped withtube insulation. System toachieve an overall U-valueof 2.2W/m2K.*Supplier: Glidevale Ltd, 2 Brooklands Road, Sale,Cheshire M33 3SS,Telephone: 0161 905 5700Fax: 0161 905 2085.Email:[email protected] *delete as applicable

Pitched roof flashings� � � � Universal Slate � � � � Universal Tile (All types) ●� � � � Universal Standing seam ●� � � � Traditional Slate� � � � Traditional Tile

Flat roof flashings� � � � Universal Single Ply � � � � Universal Torch on� � � � Universal Standing seam ●

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .SUNSCOOP™ TUBULAR ROOF INTERFACE

Roof interface flashingsA range of dedicated roof flashings isavailable for different types of pitched andflat roof coverings, as shown below.

● Requires a site-fabricated upstand.

350m

m d

iam

. tub

e

250m

m d

iam

. tub

e

450m

m d

iam

. tub

e

530m

m d

iam

. tub

e

Health and safetyThe Sunscoop glazing and flashings havebeen impact-tested to BS EN 1873 ModularRooflights and may be deemed to be non-fragile for HSG33 Safety in Roofwork.

The Sunscoop glazing and flashings have anAA fire rating to BS 476: Part 3: 2004, andcan therefore be used on roofs withoutrestriction on number, spacing or position.

Pitched roof flashings

Flat roof flashings

Low profile glazing on plain tiles

Low profile glazing on slate pitched roof

Traditional skylight

Universal single ply on flat roof

Low profile glazing on pitched roof

Page 8: NATURAL DAYLIGHT SOLUTIONS - Glidevale · most people prefer a working environment with daylight to one without. It references ... Health and Wellbeing Section HW01 and the Energy

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .SUNSCOOP™ TUBULAR COMPONENTS

Anodised aluminium base material

Bonding layer

Pure super silver or pure aluminium layer

Super reflective (LR) oxide layer

Super reflective (HR) oxide layer

Roof-mounted glazingSunscoop glazing is manufactured from3.0mm clear uv-stabilised polycarbonatewith 92% light transmission.

The glazing is available in two types;

Square dome fitted to a builders kerb orsupplied insulated upstand.

Traditional skylight fitted within tile andslate coverings. For further information seepage 7.

Both have a 10-year warranty (supported bythe polycarbonate manufacturer) againstloss of impact strength, excessive yellowingand loss of light transmission.

The warranty also covers any effects of theforming process. Not all manufacturers offerthis warranty.

Polycarbonate secondary glazing is alsoavailable to maximise insulation levels alongwith the use of tube insulation (suppliedseparately).

Tubes and elbowsTubes and elbows are anodised aluminiumwith a multi-layer specular coating whichensures pure white light with no colourshift, even after multiple reflections downthe light tube / shaft. The material calledSR98 Mirror incorporates a pure super silverlayer and has a total reflectance of 98%.

The multi-layer optical coating system isatomically bonded to the substrate.Laminated or glued reflective sheets are notused.

It has a 25-year product warranty whichguarantees that the material will not splinter,yellow, darken, peel off, blister, crack ordevelop any other surface degradation whichcould reduce overall reflectivity, even afterprolonged uv exposure. The finished materialsare electrostatically neutral and will notattract airborne dust even during installation.

SizesTubular systems diameter: 250mm, 350mm, 450mm, or 530mm.Starter tube length: 300mm.Elbow adjustment: up to 30°.Intermediate tube: 600mm.Can be cut as required on site.

Low profile glazing on slate pitched roof

Low profile glazing on plain tiles

NATURAL DAYLIGHT SOLUTIONS

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . .

Page 9: NATURAL DAYLIGHT SOLUTIONS - Glidevale · most people prefer a working environment with daylight to one without. It references ... Health and Wellbeing Section HW01 and the Energy

9

Ceiling diffusers

Circular ceiling diffuserThe standard recessed ceiling diffuser for alltube sizes, designed to maximise lighttransmission. Its translucent surfaceprovides privacy and spreads the lightefficiently throughout the room.

Manufactured from diffused polycarbonatewith white-capped ABS ceiling ring to hidefixings. Also available in chrome or brasseffect finish.

Skyview diffuser, squareOptional for 450mm and 530mm tube only.Similar to the circular Skyview but mountedin a 600 x 600mm polycarbonate panelwhich can be fitted in a suspended ceiling.

Skyview diffuser, circularOptional for all tube sizes. The innovativeSkyview diffuser consists of a grid of fresnellenses which provides a wider spread of lightwithout excessive losses and enables the skyto be viewed.

Integral electric light fittingThe Sunscoop can be supplied with anoptional integral electric light fitting (two on450 and 530mm systems) which takes a 13Wor 20W low-energy lamp (equivalent to a65W or 100W conventional lamp). Thisavoids the need for an additional light fittingfor night-time use.

Light-attenuating dampersControl over the light level entering theroom may be required at certain times, forexample in conference rooms, lecturetheatres, classrooms and hospital wards.

The optional Sunscoop motorised light-attenuating damper provides this control; itis actuated from a wall switch, separatelyavailable.

Fire protection collarsIn longer Sunscoop systems the tubing maypass through an intermediate floor or ceilingthat provides fire separation. As with anyducted system it is important that it does notform a path for fire.

Fire protection collars providing up to 120minutes fire resistance to BS 476: Part 20:1987 are available for all sizes of Sunscoop

Tube Insulation (supplied separately)Specifically designed to contribute to theoverall thermal performance of the system.All exposed tubes and elbows withinunheated voids should be lagged with tubeinsulation to reduce heat loss and the risk ofcondensation within the tube.

Thermal insulationOur Technical Services Department canprovide computer calculations of U-values indifferent roof constructions using Sunscooprooflights, including the use of secondaryglazing skins and/or tube insulation, tocomply with Building Regulations Part L2010.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 10: NATURAL DAYLIGHT SOLUTIONS - Glidevale · most people prefer a working environment with daylight to one without. It references ... Health and Wellbeing Section HW01 and the Energy

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .SUNSCOOP iPSV™ COMBINED LIGHT & VENTILATION UNIT

The Glidevale Sunscoop iPSV™ system isdesigned to provide both natural daylight

and ventilation to bathrooms, toilets,kitchens, en suites and other similar areas,in both domestic and commercialapplications.

Natural daylight enters through a roof-mounted glazing unit and is reflected down the highly reflective tubing througha Skyview ceiling diffuser. This innovativediffuser consists of a grid of fresnel lenseswhich provides a wider spread of lightwithout excessive losses and enables the skyto be viewed.

Ventilation is controlled by the ‘intelligent’extract operated by a series of nylon bands,which respond to humidity levels andregulate the size of the air opening.

Utilising a separate ducting system allowsoptimum performance from both units - theshortest possible length to maximise naturaldaylight through the ceiling diffuser and aseparate duct for the extract to optimumlength for the stack effect.

Key features● No electrical connection or power source

is required so the system is naturallyenergy efficient.Intelligent humidity controlled extractresponds automatically to changes inrelative humidity giving greaterventilation when humidity is high whilstpreventing unnecessary ventilation andheat loss when humidity is low.

● 24 hour condensation control with gentleextraction - operates all day and every dayas required combating condensation andmould growth.

● Completely silent in operation.● Complies with the requirements of

Approved Document F.● Minimal maintenance - no mechanical

components to go wrong. No costly solarpanels or battery backups.

● Automatic response and no operatingcontrols, ideal for special needsapplications.

● Tests by Building Research Establishment(BRE) have shown an intelligent passivestack system incorporating a humiditysensitive extract gives a 15 - 40% savingin ventilation heat loss dependent onoccupancy levels.

● Thermal modelling by De MontfortUniversity has shown that the intelligentpassive stack system operates effectivelyeven in summer months and internalbathrooms. The research alsodemonstrated effectiveness even in veryairtight dwellings.

● Can be supplied with optional integralelectric light fitting which takes a lowenergy bulb to avoid the need foradditional light fitting for night time use.

Size250mm diameter Sunscoop Ventilation unitarea provides 12,270mm2 at maximumhumidity with 125mm ducting.

TT9 Versatile tile ventilator

Flexible ducting (support and insulationomitted for clarity)

Ceiling (insulation omitted for clarity)

Low profile glazing onUniversal tile flashing

SR 98 Mirror reflective tubeguides daylight down to theceiling diffuser (insulationomitted for clarity)

Combined extract ventilatorand Skyview diffuser

NATURAL DAYLIGHT SOLUTIONS

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 11: NATURAL DAYLIGHT SOLUTIONS - Glidevale · most people prefer a working environment with daylight to one without. It references ... Health and Wellbeing Section HW01 and the Energy

NATURAL DAYLIGHT SOLUTIONS

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

. . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .SUNSCOOP™ HYBRID

The Sunscoop™ hybrid is a 350mm unitwith a daylight controlled dimmable low

energy compact fluorescent luminaireintegrated into the ceiling diffuser assemblyto provide a more consistent light leveldespite changing external daylightconditions.The CIBSE Lighting Guide 10 - Daylightingstates that: “Case studies have shown that ina conventionally daylit commercial buildingthe choice of control can make 30-40%difference to the resulting light use”. The Sunscoop hybrid has a control unitwhich controls both occupancy and daylightlevels, maximising the energy savings fromlighting.

Key features● The Sunscoop hybrid incorporates a light

sensor which is programmed to turn onwhen the light level inside the room dropsbelow a certain level.

● Luminaire turns on with optional ‘softstart’, allowing a gradual increase in lightoutput and adjustment to the requiredlevel.

● The Sunscoop hybrid incorporates alighting controller, lux sensor and PIRpresence detector.

● When the unit determines there isadequate natural light available, the lampis automatically turned off.

● When light levels fall, the lamp isswitched back on and its output continuesto be regulated by the daylight sensor.

● The programmable PIR presence detectorwill turn off the lamp when the space isunoccupied irrespective of the light level.

Ceiling Diffuser / LuminaireThe unit comprises a 350mm standarddiffuser with option for Skyview type. Theadjacent luminaire features a white powdercoated spun aluminium bezel and a diamondfaceted vacuum metallised aluminiumreflector housing a dimmable 26W compactfluorescent lamp. Sensor and control gearare pre-fitted.

Sizes350mm diameter unit contains onedownlight, which at full capacity producesan output of 1800 lumens.

AppearanceWhite ABS ceiling diffuser ring toencompass both Sunscoop diffuser anddownlight assembly.

PerformanceThe sensor which is looking directlydownward continously monitors the lightlevel reflected back to the ceiling andregulates the output of the compactfluorescent lamp to maintain an approximatepre-determined light level.

Note: Since daylighting and room conditionscan change continuously, the lighting levelachieved may vary to some extent from thepre-set level.

Specification clause

Natural daylight andartificial lighting to …rooms to be provided bymeans of GlidevaleSunscoop hybrid systemcomprising:Roof-mounted low profileglazing of 3.0mm clearuv-stabilisedpolycarbonate covered by10-year warranty againstloss of impact strength,excessive yellowing andloss of light transmission.Roof interface flashing tobe ... To have AA fire rating toBS 476: Part 3; 2004.Tubes and elbows to beSR98 Mirror withreflectance 98% and 25-year warranty. System diameter: 350mmCircular recessed ceilingdiffuser of diffusedpolycarbonate with white-capped ABS ceiling ring /Skyview circular diffuser*incorporating daylightcontrolled low energycompact fluorescentluminaire, lightingcontroller, lux sensor andPIR presence detector.Options to be fitted: Lightand sun deflector (LSD),polycarbonate secondaryglazing skin, light-attenuating damper, fireprotection collar.*All exposed tubes andelbows within unheatedvoids to be wrapped withtube insulation. System toachieve an overall U-valueof 2.2W/m2K.*Supplier: Glidevale Ltd, 2 Brooklands Road, Sale,Cheshire M33 3SS,Telephone: 0161 905 5700Fax: 0161 905 2085.Email:[email protected] *delete as applicable

Page 12: NATURAL DAYLIGHT SOLUTIONS - Glidevale · most people prefer a working environment with daylight to one without. It references ... Health and Wellbeing Section HW01 and the Energy

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Metrodome is an all-aluminium rooflightrange offering ventilation options and

thermal efficiency, with a choice of triple ordouble skin polycarbonate glazing. Suitablefor new-build or refurbishment, on bothwarm and cold deck flat or low-pitched roofs.Non-standard sizes can be made to suitexisting roof openings and kerbs. Accesshatches are also available.

Key features● All-aluminium design incorporating

double skin upstand.● Thermally enhanced glazing frame

providing a high level of security.● Driving rain resistant.● Independently impact tested, may be

deemed non-fragile.● Standard or humidity-sensitive trickle

ventilation options.● Available triple or double glazed.● Rooflights can be manufactured to suit

non-standard roof openings.

AccessoriesA range of complementary rooflightaccessories is available, including:● Metroglazing triple or double skin

polycarbonate domes and pyramids inclear, diffused or bronze, for fittingdirectly to builder’s kerbs.

● Tamper proof security fixings suppliedseparately.

● Manual opening operating poles.● Anti-vandal/security bars available, please

consult Glidevale Technical Services forfurther details.

12

Page 13: NATURAL DAYLIGHT SOLUTIONS - Glidevale · most people prefer a working environment with daylight to one without. It references ... Health and Wellbeing Section HW01 and the Energy

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

NATURAL DAYLIGHT SOLUTIONS

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Metrodome fixed closed, fitted direct to roof

Triple skin polycarbonate glazing

Aluminium frame

DV4 Delta ventilator

Insulated aluminiumupstand

Roof opening size

Triple skin polycarbonate glazing

Aluminium frame

ES4 Energy Saverventilator

Insulated aluminiumupstand with weatheringflange

Note: the finished builder’s kerb should not beless than 75mm ±5mm in width to provideadequate fixing for the rooflight upstand.

Metrodome fixed closed, on builder’s kerb

Internal lining to lightwell

Overall kerb size

Roof opening size

Roof interfaceGlidevale rooflights can be supplied forfitting either directly on the roof deck, or ona builder’s kerb (usually made on site).

In new build, an integral upstand is thefavoured choice as it provides a prefinishedinternal skin and an exterior to accept theroof covering. In refurbishment, a builder’skerb will often already exist.

UpstandMetrodome is supplied with an integralupstand for fitting directly to the roof deck,or with an additional weathering flange atthe base of the upstand for fitting to abuilder’s kerb. The upstand is manufacturedfrom double skin mill finish aluminium withan insulated core, mitred and welded atcorners. The internal face is finished whitefor maximum light reflectance.

GlazingTriple or double skin polycarbonate withvented air gap, in extruded mill finishaluminium frame with mitred and weldedcorners. Available in clear, diffused or bronzeglazing in dome or pyramid shapes.

The glazing comes with a 10 year postformedwarranty supported by the polycarbonatemanufacturer against loss of impactstrength, excessive yellowing and loss oflight transmission.

OpeningAvailable either fixed closed, manual openingor electric opening. Opening options open toa height of 300mm. For rapid ventilationareas available see table opposite.

Metrodome sizesRoof opening size Daylight Max. opening(mm x mm) area (m2) area (m2)

600 x 600 0.135 0.139750 x 750 0.270 0.274900 x 600 0.303 0.251900 x 900 0.448 0.4121050 x 750 0.426 0.4151050 x 1050 0.672 0.4991200 x 900 0.650 0.5021200 x 1200 0.941 0.5961350 x 750 0.582 0.5061350 x 1050 0.918 0.5881350 x 1350 1.524 0.6841650 x 1200 1.377 0.7321650 x 1350 1.590 0.7741950 x 1350 1.926 0.864

Electric opening

Manual opening

METRODOME MODULAR ROOFLIGHTS

Page 14: NATURAL DAYLIGHT SOLUTIONS - Glidevale · most people prefer a working environment with daylight to one without. It references ... Health and Wellbeing Section HW01 and the Energy

Insulated aluminium lid (or may be glazed)

Gas strut

Specification clause

Delete items not requiredRooflights to be GlidevaleMetrodome, manufacturedto BS EN ISO 9001Supplier: Glidevale Ltd, 2 Brooklands Road, Sale,Cheshire M33 3SS,Telephone: 0161 905 5700Fax: 0161 905 2085.Email:[email protected]

Sizes: ..... Glazing: double/ tripleskin polycarbonate withventilated air gap inextruded mill finishaluminium frame withmitred and weldedcorners. Colour: clear/ diffused/opal/ bronze. Shape: dome/ pyramid.Roof deck upstand:205mm high withinsulated core, mitred andwelded corners.Builder’s kerb upstand:160mm high withinsulated core, mitred andwelded corners.Opening: fixed closed/manual opening/ electricopening to height of300mm.Ventilation: ..... DV4 Deltaadjustable ventilators/ ES4humidity controlledventilators fitted torooflight upstand.Internal fire spread ratingClass 1Y, external firespread designation AA.

Latch mechanism

METRODOME ROOF ACCESS HATCH

DescriptionMetrodome Roof Hatches provide access to aroof from inside a building. The constructionis similar to the standard rooflight but thetop opens to 90° and is supported by twin‘slip and stick’ gas struts. Tops are availableeither glazed or insulated aluminium. An internal latch retains the top when closedand can be secured with a padlock (notsupplied). These units are not available forbuilder’s kerbs.

SizeThe access hatch is available in the followingsizes: 900 x 900, 1050 x 1050, 1200 x 900 and1200 x 1200mm.

Thermal insulationThe insulated upstand and double or tripleskin glazing, with vented air gap, give goodthermal insulation and minimise the risk ofcondensation.

The overall calculated U-value for a 600 x600mm unit with triple glazing and upstandis 1.99W/m2K.

Glidevale Technical Services Department canprovide computer calculations of U-valuesfor given rooflight sizes in different flat roofconstructions to comply with BuildingRegulations Part L 2010. The calculated U value will vary with the size of rooflight,due to the changing ratios of upstand,glazing and frame area.

Internal and external fire spread (B2/B4)The internal surfaces of the rooflightupstand and frame are non combustible andwould achieve a Class 1Y rating when testedto BS 476: Part 7: 1987.

Polycarbonate glazing a minimum of 3.0mmthick with a Class 1 rating is deemed byBuilding Regulations Approved DocumentB4 to be rated AA.

Metrodome rooflights can therefore be usedwithout restriction on size or spacing in alltypes of room and circulation space, exceptprotected stairways.

Weather resistanceMetrodome rooflights are deluge and drivingrain resistant as demonstrated by test.

Non-fragilityMetrodome rooflights meet the highest levelof impact resistance (1200 joules) to draftstandard BS EN 1873 in BRE tests, and maybe considered non-fragile under the latestguidelines of HSG33 ‘Health and safety inroof work’.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

NATURAL DAYLIGHT SOLUTIONS

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

METRODOME MODULAR ROOFLIGHTS

Page 15: NATURAL DAYLIGHT SOLUTIONS - Glidevale · most people prefer a working environment with daylight to one without. It references ... Health and Wellbeing Section HW01 and the Energy

15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .METROGLAZING

Glidevale Metroglazing units are availablefor fixing directly to a builder’s kerb

where replacement glazing or upgrading ofappearance or thermal performance isrequired.

They are available in a range of standardsizes with double or triple skinpolycarbonate glazing in Clear, Diffused orBronze with either Dome or Pyramid shapes.Tamper resistant glazing fixings, aresupplied - see table below.

SITEWORK

Handling and storageTo reduce the risk of damage, all Metrorooflights are delivered to site shrink-wrapped in polythene with additional cornerand glazing protection. All rooflights mustbe handled with care, particularly whenhoisting them onto the roof. Store out ofdirect sunlight on a dry area, on edge, withseparating pieces between. Never stackrooflights on top of each other.

MaintenanceMaintenance is not normally requiredbeyond occasional cleaning of glazing. Usemild non-alkaline detergent and plenty ofwater; take care to minimise surfacescratching which is inevitable with allplastics.

Glazing fixingsOverall Number of fixingskerb size per unit

475 x 475 8625 x 625 8775 x 475 10775 x 775 12925 x 625 10925 x 925 121075 x 775 141075 x 1075 161225 x 625 121225 x 925 141225 x 1225 161525 x 1075 181525 x 1225 181525 x 1525 201825 x 1225 20

NATURAL DAYLIGHT SOLUTIONS

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 16: NATURAL DAYLIGHT SOLUTIONS - Glidevale · most people prefer a working environment with daylight to one without. It references ... Health and Wellbeing Section HW01 and the Energy

Prod

uced

by

Ted

Has

ting

s/R

ackl

ey D

esig

n 44

64

. . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .FURTHER INFORMATION

NATURAL DAYLIGHT SOLUTIONS

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

GLIDEVALE LIMITED2 Brooklands Road, Sale, Cheshire M33 3SS Tel: 0161-905 5700 Fax: 0161-905 2085

Email: [email protected] Web: www.glidevale.com

Glidevale Limited maintains a policy of continuous development and reserves theright to amend product specifications without notice.

A member of the Building Product Design Group

References

Building Regulations 2000Approved Document B (Fire Safety) Volume 2-Buildings other than dwellinghouses (2006edition): B2 Internal fire spread (linings), B3Internal fire spread (structure), B4 Externalfire spread.

Approved Document F Ventilation (2006edition).

Approved Document L2A 2006 Conservationof fuel and power (New buildings other thandwellings) (2006 edition).

Approved Document L2B 2006 Conservationof fuel and power (Existing buildings otherthan dwellings) (2006 edition).

BS 5250: 2011 Code of practice for thecontrol of condensation in buildings.

BS 5720: 1979 Code of practice formechanical ventilation and air conditioning.

BS 6229: 1982 Code of practice for flat roofswith continuously supported roof coverings.

BS 8206 Lighting for buildings: Part 2: 1992Code of practice for daylighting.

Quality AssuranceThe Glidevale Sunscoop system has beendesigned, developed and manufacturedunder a BS EN ISO 9001 QualityManagement System. Independent auditingprovides the user with assurance that theproducts will fulfil their intended purpose.

Operational commitmentAs part of our commitment to minimisingour impact on the environment, and tocontinuous improvement in our methods ofoperation, Glidevale is accredited to ISO 14001 Environmental Management,OHSAS 18001 Health and SafetyManagement, and ISO 9001 QualityManagement Systems.

ServicesFor further information and advice on theselection and design of Sunscoop tubularand Metro modular rooflight installationsplease consult Glidevale Technical Services.

Other productsGlidevale market a wide range of otherbuilding products including roof ventilationand roofing accessories, underfloor andcavity wall vents, Protect underlays andmembranes, and loft access traps.

GB Glidevale Sunscoop tubular and Metro modular rooflights are made in Great Britain.